Haier Air Conditioner HSU 18HRA103 R2 User Manual

SPLIT TYPE ROOM AIR CONDITIONER  
OPERATION MANUAL  
Contents  
CAUTIONS  
1
2
3
6
7
PARTS AND FUNCTIONS  
OPERATION  
HSU-09HR03/R2(DB)  
HSU-12HR03/R2(DB)  
HSM09HRAC03/R2(DB)  
HSM12HRAC03/R2(DB)  
HSM18HRAC03/R2(DB)  
HSU-09HRA103/R2  
MAINTENANCE  
TROUBLE SHOOTING  
HSU-12HRA103/R2  
HSU-18HRA103/R2  
Please read this operation manual before using the air conditioner.  
Keep this operation manual for future reference.  
0010523724  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Base Operation  
Emergency operation and test operation  
Pi  
Emergency Operation:  
Use this ope ation only when the remote controller  
r
is defective or lost.  
Remote controller  
When the emergency operation switch is  
, which  
pressed,the" Pi "sound is heard once  
means  
the start of this operation.  
In this operation, the system automatically selects  
operation modes,cooling or fan or heat,  
the  
according to the room temperature.  
.
Room  
Timer  
mode  
Operation Designated  
Air flow  
temperature mode  
temperature  
26OC  
ABOVE 23OC  
COOLING  
AUTOMATIC  
AUTOMATIC  
NO  
NO  
BELOW 23OC  
HEAT  
23OC  
(Cooling only uint  
Operation Designated  
mode temperature  
Timer  
Air flow  
AUTOMATIC  
Room temperature  
mode  
NO  
BELOW 23OC  
FAN  
26OC  
It is not possible to operate in dry mode.  
1. Unit start  
Press ON/OFF on the remote controller, unit starts.  
2.Select operation mode  
Test operation:  
Test operation switch is the same as emergency switch.  
Use this switch in the test operation when the room  
temperature is below 16oC, do not use it in the  
normal operation.  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
Pi Pi  
Continue to press the test operation  
switch for more than 5 seconds. After  
AUTO COOL  
DRY  
FAN  
HEAT  
you hear the "Pi" sound twice,  
release  
3.Select temp.setting  
your finger from the switch: the cooling  
/
TEMP-  
Press TEMP+  
button  
TEMP+  
operation starts with the air flow speed "Hi".  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Air Flow Direction Adjustment  
1.Status display of air flow  
Vertical flap  
TEMP-  
Select a desired temperature.  
4.Fan speed selection  
Pos.1  
Pos.4  
Pos.2  
Pos.5  
Pos.3  
Pos.6  
Press FAN button. For each press, fan speed changes  
(Auto swing)  
as  
follows:  
Remote controller:  
2.Left and right air flow adjustment(manual)  
Move the vertical blade by a knob on air conditioner  
to adjust left and right direction referring to Fig.  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
Remote  
Controller  
Operation  
Mode  
Display Board  
Note  
Under the mode of auto operation, air conditioner  
will automatically select Cool or Heat operation  
according to room temperature. When FAN is set  
to AUTO, the air conditioner automatically adjusts  
the fan speed according to room temperature.  
Cautions:  
AUTO  
COOL  
When adjusting the flap by hand,turn off the unit.  
When humidity is high,condensate water might occur  
at air outlet if all vertical louvers are adjusted to left or  
right.  
In DRY mode, when room temperature becomes  
lower than temp.setting+2oC, unit will run  
intermittently at LOW speed regardless of FAN  
setting.  
DRY  
It is advisable not to keep horizontal flap at downward  
mode ,  
position for a long time in COOLor DRY  
otherwise, condensate water might occur.  
HEAT  
Note:  
In FAN operation mode , the unit will not operate in  
When restart after remote turning off, the remote  
controller will automatically memorize the previous  
set swing position.  
COOL or  
HEAT mode but only in FAN mode ,  
AUTO is not available in  
FAN mode. And temp.  
FAN  
nothing  
setting is disabled. In FAN mode, sleep operation  
is not available.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
In AUTO mode  
3.  
Sleep Operation  
The unit operaters in corresponding sleep mode  
adapted to the automatically selected operation  
mode.  
Before going to bed,you can simply press the SLEEP  
button and unit will operate in SLEEP mode and bring  
you a sound sleep.  
4. In FAN mode  
It has no SLEEP function.  
5.Set the wind speed change when sleeping  
If the wind speed is high or middle before  
setting for the sleep, set for lowing the wind  
speed after sleeping.  
If it is low wind, no change.  
Note  
When TIMER function is set, the sleeping function  
can't be set up .After the sleeping function is set up,  
if user resets TIMER function, the sleeping function  
will be cancelled;the machine will be in the state of  
timing-on.  
Use of SLEEP function  
After the unit starts,set the operation status,  
then press SLEEP button before which the  
clock must be adjusted and time being set.  
POWER/SOFT Operation  
Operation Mode  
(1)  
1. In COOL,DRY mode  
POWER Operation  
When you need rapid heating or cooling, you can use this  
function. In COOL mode, fan speed automatically takes  
high speed of AUTO fan mode. In HEAT mode, fan speed  
automatically takes medial speed of AUTO fan mode.  
1 hours after SLEEP mode starts,temp.will become  
O
1
higher than temp.setting.After another 1 hours,  
C
O
temp.rises by 1 C futher.The unit will run for further  
6 hours then stops Temp. is higher than temp.  
setting so that room temperature won’t be too low  
for your sleep.  
(2)  
SOFT Operation  
You can use this function when silence is needed for  
rest or reading. In SOFT operation mode, fan speed  
automatically takes low speed of AUTO fan mode.  
SLEEP operation starts  
SLEEP operation stops  
Approx.6hrs  
Note  
During POWER operation, in rapid HEAT or COOL  
mode ,the room will show inhomogeneous temperature  
distribution. Long period SOFT operation will cause  
effect of not too cool or not too warm.  
Rises 1OC  
Rises 1OC  
1 hr  
1 hr  
Temp.setting  
Unit stop  
To cancel POWER or SOFT operation  
Press POWER/SOFT button again ,POWER or SOFT  
disappears.  
In COOL, DRY mode  
In HEAT mode  
2.  
The following functions and related displays are not available  
HSU-09HRA103/R2HSU-12HRA103/R2  
1 hours after SLEEP mode starts,temp will  
O
become 2 lower than temp.setting.After  
C
O
another 1 hours,temp decrease by 2  
C
HEALTHY Operation  
futher.After more another 3hours,temp.rises  
O
C
by 1 futher.The unit will run for further 3  
hours then stops.Temp.is lower than temp.  
setting so that room temperature won’t be  
too high for your sleep.  
Temp.setting  
1 hr  
Unit stop  
O
Decreases 2 C  
1 hr  
O
Decreases 2 C  
Healthy Negative ions  
The anion generator in the airconditioner can  
generate a lot of anion effectively balance the  
quantity of position and anion in the air and also  
to kill bacteria and speed up the dust sediment in  
the room and finally clean the air in the room.  
3 hrs  
Rises 1OC  
3 hrs  
SLEEP  
operation stops  
SLEEP  
operation starts  
In HEAT mode  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
EUROPEAN REGULATIONS  
CONFORMITY FOR THE MODELS  
Operation  
CE  
Timer On/Off On-Off Operation  
All the products are in conformity with the following  
European provision:  
Set clock correctly before starting TIMER operation.  
1.After unit starts, select your desired operation mode.  
2.Press TIMER button to change TIMER mode. Every  
time the button is pressed, display changes as follows:  
Remote controller:  
- Low Voltage Directive 73/23/EEC  
- Low Voltage Directive 2006/95/EC  
-Electomagnetic CompatibilitY 89/336/EEC  
-Electomagnetic CompatibilitY 2004/108/EC  
ROHS  
The products are fulfilled with the requirements in the  
directive 2002/95/EEC of the European parliament and of  
council on the Restriction of the use of Certain Hazardous  
Substances in Electrical and Electronic Equipment (EU  
RoHS Directive)  
BLANK  
TIMER ON TIMER OFF  
TIMER ON-OFF  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF or TIMER ON-OFF). " "or " "will flash.  
WEEE  
In accordance with the directive 2002/96/CE of the European  
parliament, herewith we inform the consumer about the dis-  
posal requirements of the electrical and electronic products.  
3.Press TIME+ /TIME- button to set time.  
It can be adjusted within 24 hours.  
4.After setting correct time, press SET button to confirm  
"or" " on the remote controller stops flashing.  
DISPOSAL REQUIREMENTS:  
"
Your air conditioning product is marked with this  
symbol.This means that electrical and electronic  
products shall not be mixed with unsorted  
household waste. Do not try to dismantle the  
system yourself : the dismantling of the air  
5.Cancel TIMER mode  
Just press TIMER button several times until TIMER mode  
disappears.  
Hints:  
After replacing batteries or a power failure happens, time  
setting should be reset.  
conditioning system,treatment of the refrigerant, of oil and of  
other part must be done by a qualified installer in accordance  
with relevant local and national legislation. Air conditioners  
must be treated at a specialized treatment facility for reuse,  
recycling and recovery. By ensuring this product is disposed  
of correctly, you will help to prevent potential negative cons-  
equences for the environment and humen health. Please  
contact the installer or local authority for more information.  
Battery must be removed from the remote controller and dis-  
posed of separately in accordance with relevant local and  
nationl legislation.  
Remote controller possesses memory function,when use  
TIMER mode next time, just press SET button after mode  
selecting if time setting is the same as previous one.  
According to the Time setting sequence of TIMER ON or  
TIMER OFF, either Start-Stop or Stop-Start can be  
achieved.  
Healthy airflow Operation  
1.Press ON/OFF to starting  
Setting the comfort work conditions.  
2.The setting of healthy airflow function  
IMPORTANT INFORMATION REGA-  
RDING THE REFRIGERANT USED  
,
appears on the  
1).Press the button of healthy airflow  
display. Horizontal airflow sending.  
blows direct to the body.  
Avoid the airflow  
Contains fluorinated greenhouse gases  
covered by the Kyoto Protocol  
A
1=  
kg  
kg  
R410A  
2).Press the button of healthy airflow again,  
appears on  
Avoid the airflow  
B
C
2
2=  
. Downward airflow sending.  
the displa  
y
1
blows direct to the body.  
3.The cancel of the healthy airflow function  
Press the button of healthy airflow again,  
1+2=  
kg  
D
F
E
goes on  
the unit  
This product contains fluorinated greenhouse gases covered by  
the Kyoto Protocol. Do not vent into the atmosphere.  
Refrigerant type:R410A  
working under the condition before the setting of healthy  
airflow function.  
GWP* value:1975  
GWP=global warming potential  
Please fill in with indelible ink,  
Notice: Do not direct the flap by hand. Otherwise, the  
grille will run incorrectly. If the grille is not run correctly, stop  
for a minute and then start, adjusting by remote  
controller.  
• 1  
• 2  
the factory refrigerant charge of the product  
the additional refrigerant amount charged in the field and  
• 1+2 the total refrigerant charge  
Note:  
on the refrigerant charge label supplied with the product.  
The filled out label must be adhered in the proximity of the product  
charging port (e.g. onto the inside of the stop value cover).  
A contains fluorinated greenhouse gases covered by the Kyoto  
Protocol  
B factory refrigerant charge of the product: see unit name plate  
C additional refrigerant amount charged in the field  
D total refrigerant charge  
1.After setting the healthy airflow function, the position  
grill is fixed.  
2.In heating, it is better to select the  
3.In cooling, it is better to select the  
mode.  
mode.  
4.In cooling and dry, using the air conditioner for a long  
time under the high air humidity, condensate water may  
occur at the grille .  
E outdoor unit  
F refrigerant cylinder and manifold for charging  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
For Smart Use of The Air Conditioner  
Indoor Body  
Remote Controller  
Setting of proper room  
temperature  
Do not block the air inlet  
or outlet  
Proper  
temperature  
wipe the air conditioner by using a  
soft and dry cloth.For serious stains,  
use a neutral detergent diluted with  
water.Wring the water out of the  
cloth before wiping,then wipe off the  
detergent completely.  
Do not usewater,wipe the controller  
with a dry cloth.Do not use glass  
cleaner or chemical cloth.  
Do not use the following for cleaning  
Close doors and windows  
during operation  
Use the timer effectively  
O
O
Gasoline,benzine, thinner or cleanser Hot water over 40 C(104 F) may  
may damage the coating of the unit.  
cause discoloring or deformation.  
During cooling operation  
prevent the penetration  
of direct sunlight with  
curtain or blind  
Air Filter cleaning  
Open the inlet grille by pulling it upward.  
Remove the filter.  
Push up the filter's center tab slightly until it is  
released from the stopper, and remove the filter downward.  
Clean the filter.  
If the unit is not to be used  
for a long time, turn off the  
power supply main switch.  
Use the louvers effectively  
Use a vacuum cleaner to remove dust, or wash the filter with  
water.After washing, dry the filter completely in the shade.  
Attach the filter.  
Attach the filter correctly so that the "FRONT" indication  
is facing to the front.Make sure that the filter is  
completely  
fixed behind the stopper.If theright  
Once every  
two weeks  
and left filters are not attached correctly, that  
may cause defects.  
OFF  
Close the inlet grille.  
Replacement of Air Purifying Filter  
1.Open the lnlet Grille  
4.Attach the standard air filter  
(Necessary installation)  
Prop up the inlet grille by using a  
small device named grille-support  
which located in the right side of  
the indoor unit.  
ATTENTION:  
The white side of the photocatalyst air purifying filter  
face outside,and the black side face the unit The green  
side of the bacteria-killing medium air purifying filter face  
outside,and the white side face the unit.  
2.Detach the standard air filter  
Slide the knob slightly upward to  
release the filter, then withdraw it.  
5.Close the Inlet Grille  
Close the Grille surely  
NOTE:  
Detach old Air Purifying Filter  
The photocatalyst air purifying filter will be solarized in fixed  
time. In normal family, it will be solarized every 6 months.  
The bacteria-killing medium air purifying filter will be used  
for a long time,no need for replacement. But in the period  
of using them ,you should remove the dust frequently by  
using vacuum cleaner or flaping them lightly,otherwise ,  
its performance will be affected.  
3.Attach Air Purifying Filter  
Put air purifying filter appliances into the  
right and left filter frames.  
Please keep the bacteria-killing medium air purifying filter in  
the cool and dry conditions avoid long time directly sunshine  
when you stop using it,or its ability of sterilization will be  
reduced.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cautions  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
WARNING  
When abnormality such as burnt-small found,  
immediately stop the operation button and  
contact sales shop.  
Check proper  
installation of the  
drainage securely  
Use an exclusive  
power source  
with a circuit  
breaker  
STRICT  
OFF  
STRICT  
ENFORCEMENT  
ENFORCEMENT  
1.Do not use power supply cord extended  
or connected in halfway  
Connect power supply cord  
to the outlet completely  
Use the proper voltage  
2.Do not install in the place where there is any  
possibility of inflammable gas leakage around the unit.  
3.Do not get the unit exposed  
to vapor or oil steam.  
STRICT  
ENFORCEMENT  
STRICT  
ENFORCEMENT  
PROHIBITION  
Take care not to damage  
the power supply cord.  
Do not use power supply  
cord in a bundle.  
Do not insert objects into the air  
inlet or outlet.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not channel the air flow directly  
at people, especially at infants or  
the aged.  
Do not start or stop the  
operation by disconnecting  
the power supply cord  
and so on.  
Do not try to repair or  
reconstruct by yourself.  
Connect the earth  
cable.  
earthing  
PROHIBITION  
PROHIBITION  
CAUTION  
Take fresh air occasionally especially  
when gas appliance is running at the  
same time.  
Do not operate the switch with  
wet hand.  
Do not use for the purpose of storage of  
food, art work, precise equipment,  
breeding, or cultivation.  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
Do not pour water onto the unit  
for cleaning  
Do not install the unit near a fireplace  
or other heating apparatus.  
Check good condition of the  
installation stand  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not place flower vase or water  
containers on the top of the unit.  
Do not place any objects on or  
climb on the unit.  
Do not place animals or plants in  
the direct path of the air flow  
PROHIBITION  
PROHIBITION  
PROHIBITION  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble shooting  
Before asking for service, check the following  
first.  
Cautions  
Do not obstruct or cover the ventilation  
conditoner.Do not put fingers or any other things into the  
grille of the air  
inlet/outlet and swing louver.  
Do not allow children to play with the air conditioner.In no  
case should children be allowed to sit on the outdoor unit.  
Phenomenon  
Cause or check points  
When unit is stopped, it won't restart  
immediately until 3 minutes have  
elapsed to protect the system.  
When the electric plug is pulled out  
and reinserted, the protection circuit  
will work for 3 minutes to protect the  
air conditioner.  
The system  
does not restart  
immediately.  
Specifications  
The refrigerating circuit is leak-proof.  
The machine is adaptive in following situation  
1.Applicable ambient temperature range:  
During unit operation or at stop,  
a swishing or gurgling noise may  
be heard.At first 2-3 minutes after  
unit start, this noise is more noticeable.  
(This noise is generated by  
refrigerant flowing in the system.)  
During unit operation, a cracking  
noise may be heard.This noise is  
generated by the casing expanding  
or shrinking because of  
32oC/23oC  
Maximum:D.B/W.B  
Noise is heard  
Indoor  
21oC/15oC  
Minimum:D.B/W.B  
Maximum:D.B/W.B 43oC/26oC  
Cooling  
Outdoor  
Indoor  
Minimum:  
18oC  
D.B  
27oC  
Maximum:D.B  
Minimum: D.B  
0oC  
Heating  
Normal  
Performance  
inspection  
Maximum:D.B/W.B 24oC/18oC  
Minimum:D.B/W.B 7oC/-8oC  
Maximum:D.B/W.B 24oC/18oC  
Outdoor  
temperature changes.  
-
Should there be a big noise from  
air flow in unit operation, air  
filter may be too dirty.  
Outdoor  
-15oC  
(INVERTER)  
Minimum:D.B  
This is because the system  
circulates smells from the interior  
air such as the smell of furniture,  
paint, cigarettes.  
2. If the power supply cord is damaged, it must be replaced by the  
or its service agent or a similar  
person.  
Smells are  
generated.  
manufacturer  
qualified  
3.If the fuse of indoor unit on PC board is broken,please change  
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is  
broken,change it with the type of T.25A/250V  
Mist or steam are  
blown out.  
During COOL or DRY operation,  
indoor unit may blow out mist.  
This is due to the sudden cooling  
of indoor air.  
4. The wiring method should be in line with the local wiring standard.  
5. After installation, the power plug should be easily reached.  
6. The waste battery should be disposedproperly.  
In DRY mode, when room temperature  
becomes lower than temp.  
setting+2 oC,unit will run  
intermittently at LOW speed  
regardless of FAN setting.  
fan  
In dry mode,  
speed can’t be  
changed.  
7. The appliance is not intendedfor use  
by young children or infirm  
without supervision.  
persons  
8.Young children should be supervised to ensure that they do not play  
with the appliance.  
Is power plug inserted?  
Is there a power failure?  
Is fuse blownout?  
9. Please employ the proper power plug,which fit into the power supply  
cord.  
Is the air filter dirty?  
Normally it should be cleaned  
Poor cooling  
10. A breaker should be incorporated into  
fixed wiring. The breaker  
every 15 days.  
Multiple  
check  
should be all-pole switch and the distance betweenits two  
contacts should be not less than 3mm.  
Are there any obstacles before  
inlet and outlet?  
Is temperature set correctly?  
11 .The power plug and connecting cable must have acquired the local  
attestation.  
Are there some doors or  
windows left open?  
Is there any direct sunlight  
12.In order to protect the units,please turnoff the A/C first,and at least  
30 seconds later, cutting off the power.  
through the window during the  
cooling operation?(Use curtain)  
13.Please don't insert any sensor on 3-waystop valve pipe fitting.  
Are there too much heat sources  
or too many people in the room  
during cooling operation?  
X
HSU-09HRA103/R2  
HSU-12HRA103/R2  
0.415  
0.317  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Biscuit Joiner G0654 User Manual
Grizzly Cordless Sander G0702 User Manual
HannsG Computer Monitor HB 175APB User Manual
Harman Stove Company Stove Conquest Gas Stove User Manual
Hasbro Robotics 51472 User Manual
HP Hewlett Packard Cable Box 574412 DOC User Manual
Hunter Fan Thermostat 44360 User Manual
Hypertec Carrying Case N6198KHY User Manual
IBM Computer Drive C1B 112 Brick On Sled Carrier 128 pin HPC User Manual
i mate Cell Phone PM10A User Manual