Automated Vertical Panel Lift
This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio or television
communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:
•
•
•
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment to an outlet on a circuit other than that to which the receiver is connected
Consult the dealer or and experienced radio/TV technician for help
MSP-CM6HABV71/83
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
ASSEMBLY
1. Attach cables to weights by hand and tighten retaining nut using a 7/16" wrench.
Figure 1
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
INSTALLATION
1. Screw tracks to cabinet using 1/8” masonite space. (provides screw head clearence for double wall)
Figure 2
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
2. Level cabinet in both directions.
Figure 3
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
3. Attach door plates 1 inch down from the top with the “V” notch aligned with the panel edge.
Figure 4
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
4. Gently push to make sure that wheels are touching track.
Figure 5
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
5. Remove nuts from the studs on the wheel plates and place the panel on the mechanism.
6. Center the panel and tighten the nuts.
Figure 6
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
7. While holding back the chain attachment bracket, move the door up and down to check for balance. Also check to see if the
counterweights hit or rub the cabinet. If it does, it’s not level.
Figure 7
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
8. If the panel seems light, add weight to it. If the panel seems heavy, add weight to the counterweights.
Figure 8
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
RF Receiver Installation
ADJUSTMENTS
Install RF reciever following the instructions provided with the
receiver.
Adjust Door Travel Distance
To adjust door travel distance:
System Activation
1. Insert plug from the power supply into the jack on the top of
the motor box.
1. Set the length of travel required using the adjustable stop on
the bottom of the left hand track.
2. Press and hold the activator button on the front of the motor
box for 13 seconds.
The Status Light on the front of the motor box will begin to blink
alternately red and green. When this starts to happen release
the Activator Button. When put into "Learn Moden the system
runs back and forth several times and measures it's
environment, such as open and closed locations etc. The
system will then stop and remember these learned
measurements.
24VDC Input
Top of
Cabinet
Activator
Figure 11
System Controls and Indicators
Front of
Cabinet
Learn Mode
The CM6SV system has no limit switches. The system uses an
encoder on the motor to collect data and send it to the micro
processor’s memory. The software "learns" about its
environment (speed, time duration, stop points, etc.) during the
initial setup of the unit and retains that information until
requested to "relearn" its environment.
Figure 9
2. Plug Powercord into 115VAC outlet.
IMPORTANT ! : A quality surge protection device is
recommended.
3. Make sure nothing is obstructing movement of doors,
The unit is shipped pre-set from the factory and will then
continually adjusts to it’s enviornment on each activation.
4. Press and release the Activator Button on the front of the
Motor Box or the "Close Door button on the Remote Control.
(The doors should travel to the fully closed position)
If for some reason you want to place the system into “Learn
Mode” (such as to stop at other than its normal stop points),
Press and hold the red activator button on the front of the motor
box for approxamatly 13 seconds and then release it when the
Status Light flashes quickly red, green, red, green, red, green.
Activator
Activator Button
Figure 10
5. Press the "Open Door" button on the Remote Control.
NOTE: The mechanism has been preset to travel 34 inches. If
a different travel distance is required see "Door Travel
Adjustment below.
Figure 12
The controller will then be in “Learn Mode” (The door will move
for 3 seconds, stop for 10 seconds, and when it starts moving
again it will be in it’s “Learn Mode”).
When put into “Learn Mode” the mechanism runs back and
forth several times and measures it’s environment, such as
open and closed locations etc., and then stops and remembers
11
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
these learned measurements, so that next time the system runs
it knows where to start and stop.
Power Loss - The Status Light will be on solid red. ---- There
has been a power loss (due to an electrical storm, etc.). When
next activated the doors will move at a slow speed to their full
closed position. If the doors are already closed they will not
move. The Status Light will return to solid green and the doors
are ready for normal activation.
Status Light Codes
There is a light on the front of the mechanism motor box that
will tell through its pattern of flashes and colors what the
mechanism is doing.
Optional Control Input Connections
Control Input- 8 position RJ 45 modular phone jack
Discrete control for use with 3rd party control.
Status Indicator
•
•
Position 8- Open
Position 7- Stop
IR Receiver “Eye” input for Eubank, Inc. supplied external IR
reciever only.
•
•
Position 6 - V out
Position 5 - Vcc, 5v
Radio Power for external RF reciever only.
Position 4 - 24 VDC
Sequence control for use with 3rd party control.
Figure 13
•
Normal Doors At Rest - The Status Light will be on steady
green.
•
•
Position 3 - Sequence- Open, Stop, Close, Stop
Position 2 - Common
Normal Run Motion of Doors - The Status Light will flash in
groups of 2 green followed by a pause. In normal run motion
the doors on a Eubank mechanism have a variable speed. The
doors will start slowly, accelerate to a fast speed, and then slow
down before coming to a stop.
Discrete control for use with 3rd party control.
•
Position 1 - Close
Control Input on Front of Motor Box
Doors Obstructed - The Status Light will flash in groups of 3
red followed by a pause. If the doors meet an obstruction they
will sense the obstruction, stop momentarily, and move in the
opposite direction for a few seconds. ---- Remove the
obstruction and then activate the doors. They should return to
normal run motion.
Control Input
Doors Obstructed Both Ways - The Status Light will flash in
groups of 4 red followed by a pause. Similar to Doors
Obstructed but doors are prevented from moving in either
direction. ---- Remove the obstruction and then activate the
doors. They should return to normal run motion.
Figure 14
Travel Too Far - The Status Light will flash in groups of 5 red
followed by a pause. The motor is running but the doors are
not moving. ---- Has the motor box been uncoupled from the
track, or is the motor box bent, causing it to become uncoupled
from the track?
NOTE: Making a momentary dry contact closure between the
common and the open, closed, stop, or sequence will
activate the system in that mode.
Control Input on Front of Motor Box
Figure 15
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
MSP-CM6HABV71/83
13
Download from Www.Somanuals.com. All Manuals Search And Download.
MSP-CM6HABV71/83
Installation Instructions
USA/International
Europe
A
P
F
A
P
F
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Fellenoord 130 5611 ZB EINDHOVEN, The Netherlands
+31 (0)40 2668620
+31 (0)40 2668615
Asia Pacific
A
Room 30I, Block D, Lily YinDu International Building
LuoGang, BuJi Town, Shenzhen, CHINA. Post Code: 518112
8820-000025
¤2007 Chief Manufacturing
05/07
P
F
+86-755-8996 9226 ; 8996 9236 ; 8996 9220
+86-755-8996 9217
Download from Www.Somanuals.com. All Manuals Search And Download.
|