Chamberlain Garage Door Opener 1000SDC R, 2000SDC R User Manual

TM  
®
Garage Door Opener  
Owner’s Manual  
Model 1000SDC-R  
1/3 HP  
Model 2000SDC-R  
1/2 HP  
For Residential Use Only  
Please read this manual and the enclosed safety materials carefully!  
Fasten the manual near the garage door after installation.  
The door WILL NOT CLOSE unless the Protector System® is connected and  
properly aligned.  
Periodic checks of the opener are required to ensure safe operation.  
The model number label is located on the back of your opener.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Safety alert symbol review ...........................................2  
Install the lights and lens ..........................................19  
Attach the manual release rope and handle...............19  
Fasten the door bracket (sectional door)...................20  
Fasten the door bracket (one-piece door)..................21  
Connect door arm to trolley (sectional door)............22  
Connect door arm to trolley (one-piece door)...........23  
Adjustment section - pages 24 – 26  
Safety information and precautions ..............................3  
Testing your garage door for binding & balance ..........3  
Hardware supplied ........................................................3  
Carton inventory ...........................................................4  
Illustration of sectional door installation .....................5  
Illustration of one-piece door installation.....................5  
Assembly section - pages 6 – 7  
Travel limit adjustments............................................24  
Force adjustments .....................................................25  
Test the Protector System® ........................................26  
Test the safety reverse system ..................................26  
Operation safety instructions ......................................27  
Care of your opener ....................................................27  
Maintenance schedule.................................................27  
Operation of your opener............................................28  
Receiver & remote control programming...................29  
Having a problem?......................................................30  
Repair parts, rail assembly..........................................32  
Repair parts, installation .............................................32  
Repair parts, power unit..............................................33  
Accessories .................................................................34  
Index ...........................................................................35  
How to order repair parts............................................36  
Warranty......................................................................36  
Fasten rail to power unit .............................................6  
Install the trolley .........................................................6  
Attach the rail brackets ...............................................7  
Installation safety instructions ....................................7  
Installation section - pages 8 – 23  
Determine the header bracket location  
Sectional door ...........................................................8  
One-piece door..........................................................9  
Install the header bracket ..........................................10  
Attach the rail to the header bracket .........................11  
The Protector System® .............................................12  
Install the safety reversing sensor.............................13  
Position the opener....................................................15  
Hang the opener........................................................16  
Install the door control and connect all wires...........17  
Electrical requirements .............................................18  
Complete the safety reversing sensor installation.....18  
Start by reviewing these important safety alert symbols:  
When you see these Safety Symbols on the following pages, they will alert you to the possibility of serious injury  
or death if you do not comply with the corresponding instructions. The hazard may come from something  
mechanical or from electric shock. Read the instructions carefully.  
Mechanical  
Electrical  
When you see this Safety Symbol on the following pages, it will alert you to the possibility of damage to your  
garage door and/or the garage door opener if you do not comply with the corresponding instructions. Read the  
instructions carefully.  
This garage door opener is designed and tested to offer safe service provided it is installed, operated, maintained  
and tested in strict accordance with the safety instructions contained in this manual.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Carton Inventory  
Your garage door opener is packaged in two cartons which contain the power unit and all parts illustrated below.  
Accessories will depend on model purchased. If anything is missing, carefully check the packing material. Parts may be  
"stuck" in the foam. KEEP THE FOAM INTACT (see page 6). Hardware is listed on page 3.  
Model 2000SDC-R  
Model 1000SDC-R  
Model 2000SDC-R  
Model 1000SDC-R  
SECURITY  
SECURITY✚  
LOCK  
LIGHT  
Single-Function Remote Control  
3-Channel Remote Control  
Lighted  
Multi-Function  
Door Control Button  
Door Control Panel  
Remote Control  
Transmitter Visor Clip  
Light Lens  
2-Conductor Bell Wire  
White & White/Red  
CEILING MOUNT ONLY  
UP  
Rail Brackets  
Header Bracket  
Rail  
Assembly  
Door Bracket  
Sprocket Coupling  
Trolley  
Curved Door  
Arm Section  
Safety Sensor  
Bracket (2)  
Straight Door  
Arm Section  
Safety Labels  
and  
Literature  
(2) Safety Reversing Sensors  
(1 Sending Eye and 1 Receiving Eye)  
with  
2-Conductor White & White/Black Bell Wire  
attached  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before you begin, survey your garage area to see whether any of the conditions below apply to your installation.  
You may find it helpful to refer back to this page as you proceed with the installation of your opener.  
SECTIONAL Door or  
ONE-PIECE Door with Track Installation  
FINISHED CEILING  
Support bracket &  
fastening hardware  
is required.  
Horizontal and vertical reinforcement  
is needed for lightweight garage doors  
(fiberglass, steel, aluminum, door with glass panels, etc.).  
See page 20 for details.  
See page 16.  
Header Wall  
Extension Spring  
OR  
OR  
One-Piece Door-Extension Spring  
Torsion Spring  
Header  
Wall  
Door Center  
Access Door  
Track  
Door  
Safety  
Reversing  
Sensor  
Floor must be level  
across width of door  
Safety Reversing Sensor  
ONE-PIECE Door Without Track Installation  
FINISHED CEILING  
Support bracket &  
fastening hardware  
is required.  
See page 16.  
Header  
Wall  
Access Door  
Safety Reversing  
Sensor  
Gap between floor and bottom of  
door must not exceed 1/4".  
Safety Reversing Sensor  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembly Section: Pages 6 - 7  
ASSEMBLY STEP 1  
Fasten the Rail To the Power Unit  
NOTE: To aid in assembly and installation, replace  
the foam packing around the power unit. Remove it  
after Installation Step 5.  
• Working on a level surface, align the rail assembly with  
the power unit, as shown.  
Power Unit  
Sprocket  
Rail/Power Unit  
Bracket  
• Slip the coupling over the rail sprocket.  
Lock Nuts  
1/4"-20  
• Slide the rail through the power unit bracket until the  
coupling fits securely over the power unit sprocket.  
• Align the two screw holes in the rail with those in the  
power unit bracket. Insert two 1/4"-20x5/8" hex screws  
and lock nuts. Tighten securely with a 7/16" socket  
wrench.  
Opener  
Chassis  
Coupling  
Rail  
Sprocket  
Hex Screws  
1/4"-20x5/8"  
Foam Packaging  
Rail  
Assembly  
Hardware Shown Actual Size  
1/4" - 20  
1/4" - 20 x 5/8"  
Hex Screw  
Lock Nut  
Trolley  
ASSEMBLY STEP 2  
Install the Trolley  
As illustrated above, slide the trolley onto and along the  
bottom of the rail until it snaps firmly in place. Be certain  
to install it facing correctly: the trolley release arm must  
be horizontal (lock position), with its arrow pointed  
away from the power unit.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY STEP 3  
Attach the Rail Brackets  
1/4"-20  
Lock Nuts  
Rail  
Brackets  
• Align rail brackets to end of rail assembly, as shown.  
• Insert two 1/4"-20 x 5/8" hex screws and lock nuts.  
Tighten securely with a 7/16" socket.  
Hardware Shown Actual Size  
1/4" - 20  
Lock Nut  
1/4"-20x5/8  
Hex  
Rail  
1/4" - 20 x 5/8"  
Hex Screw  
Screws  
You have now finished assembling your garage door opener. Please read the following warnings  
before proceeding to the installation section:  
IMPORTANT INSTALLATION INSTRUCTIONS  
WARNING  
WARNING  
To reduce the risk of severe injury or death to persons:  
1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS  
2. Install only on a properly balanced and lubricated garage door. An improperly balanced door may not  
reverse and could result in severe injury or death. Repairs to cables, spring assemblies and other  
hardware must be made by a professional service person before installing opener.  
3. Disable all locks and remove all ropes connected to the garage door before installing the opener. Ropes  
connected to a garage door can cause entanglement and death.  
4. If possible, install door opener 7 feet or more above floor with the manual release handle mounted 6  
feet above the floor.  
5. Do not connect the opener to power source until instructed to do so.  
6. Locate the Door Control within sight of the door at a minimum height of 5 feet where small children  
cannot reach and away from all moving parts of the door.  
7. Install the User Safety Instruction Label on the wall adjacent to the control button and the  
Maintenance Instruction Label in a prominent location on the inside of the garage door.  
8. Upon completion of the installation, the door must reverse when it comes in contact with a one-inch  
high object or a 2x4 laid flat on the floor.  
9. Do not wear watches, rings or loose clothing while installing or servicing an opener. Jewelry or loose  
clothing can be caught in the mechanism of the garage door or the opener.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Section: Pages 8 – 23  
Installation Step 1  
Determine Header Bracket Location  
WARNING  
If the header bracket is not rigidly fastened to a  
structural support on the header wall or ceiling, the  
safety reverse system may not work properly (see page  
26). The door might not reverse when required, and  
could cause serious injury or death.  
Installation procedures vary according to garage  
door types. Follow the instructions which apply to  
your door.  
The garage door springs, cables, pulleys, brackets and  
their hardware are under extreme tension. Do not attempt  
to loosen, move or adjust them yourself. Serious  
personal injury or death could result. Call for  
professional garage door service.  
SECTIONAL Door or  
ONE PIECE Door with Track  
Finished  
Ceiling  
Vertical  
Guideline  
Header  
Wall  
• Close the door and mark the inside  
vertical centerline of the garage door.  
2x4  
Structural  
Supports  
• Extend the line onto the header wall  
above the door.  
Remember, you can fasten the header  
bracket within 4 feet of the left or right  
of the door center only if a torsion  
spring or center bearing plate is in the  
way; or you can attach it to the ceiling  
(refer to page 10) when clearance is  
minimal. (It may be mounted on the  
wall upside down if necessary, to gain  
approximately 1/2".)  
Vertical  
Guideline  
If you need to install the header bracket on  
a 2x4 (on wall or ceiling), use lag screws  
(not supplied) to securely fasten the 2x4 to  
structural supports as shown here and on  
page 9.  
• Open your door to the highest point  
of travel as shown. Draw an inter-  
secting horizontal line on the header  
wall 3" above the high point. This  
height will provide travel clearance  
for the top edge of the door.  
Ceiling  
Header  
Wall  
3"  
Header  
Wall  
3"  
Track  
Track  
Highest Point  
of Travel  
Highest Point  
of Travel  
Door  
Door  
Sectional door  
with curved track  
One-piece door  
with horizontal track  
Proceed to Step 2, page 10.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ONE-PIECE Door Without Track  
Read the Safety Instructions on page 8. They also apply to doors without tracks.  
Unfinished  
Ceiling  
• Close the door and mark the inside  
vertical centerline of your garage  
door. Extend the line onto the  
Header Wall  
Vertical  
Centerline  
2x4  
header wall above door.  
Structural Supports  
If headroom clearance is minimal,  
you can install the header bracket  
on the ceiling. See page 10.  
If you need to install the header  
bracket on a 2x4 (on wall or  
ceiling), use lag screws (not  
2x4  
Vertical  
Centerline of  
Header Support  
Garage Door  
supplied) to securely fasten the 2x4  
to structural supports as shown.  
OPTIONAL CEILING MOUNT  
FOR HEADER BRACKET  
Header Wall  
Highest Point  
Highest Point  
of Travel  
Header  
Wall  
of Travel  
Door  
Door  
Jamb  
Hardware  
Pivot  
Floor  
Floor  
One-piece door without track  
jamb hardware  
One-piece door without track  
pivot hardware  
EXAMPLE  
• Open your door to the highest point of travel as shown.  
Measure the distance from the top of the door to the  
floor. Subtract the actual height of the door. Add 8" to  
the remainder. (See Example).  
Distance from top of door  
(at highest point of travel) to floor................................92"  
Actual height of door...................................................-88"  
Remainder.......................................................................4"  
Add...............................................................................+8"  
Bracket height on header wall....................................=12"  
(Measure UP from top of CLOSED door.)  
• Close the door and draw an intersecting horizontal line  
on the header wall at the determined height.  
If the total number of inches exceeds the height  
available in your garage, use the maximum height  
possible, or refer to page 10 for ceiling installation.  
Proceed to Step 2, page 10.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
You can attach the header bracket either to the wall  
above the garage door, or to the ceiling. Follow the  
instructions which will work best for your particular  
requirements.  
Installation Step 2  
Install the Header Bracket  
Fastening the Header Bracket to the Ceiling  
Fastening the Header Bracket to the Wall  
• Center the bracket on the vertical guideline with the  
bottom edge of the bracket on the horizontal line as  
shown (with the arrow pointing toward the ceiling).  
• Extend the vertical guideline onto the ceiling as shown.  
• Center the bracket on the vertical mark, no more than 6"  
from the wall. Make sure the arrow is pointing toward  
the wall. The bracket can be mounted flush against the  
ceiling when clearance is minimal.  
• Mark either set of bracket holes (do not use the holes  
designated for ceiling mount). Drill 3/16" pilot holes  
and fasten the bracket securely to a structural support  
with the hardware provided.  
• Mark holes designated for ceiling mount only. Drill  
3/16" pilot holes and fasten bracket securely to a  
structural support with the hardware provided.  
Hardware Shown Actual Size  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 3  
Attach the Rail to the Header Bracket  
• Position the opener on the garage floor below the  
header bracket. Use packing material as a protective  
base.  
If the door spring is in the way you’ll need help. Have  
someone hold the opener securely on a temporary  
support to allow the rail to clear the spring.  
• Position the rail bracket against the header bracket.  
• Align the bracket holes and join with a clevis pin as  
shown.  
• Insert a ring fastener to secure.  
Hardware Shown Actual Size  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Protector System®  
IMPORTANT INFORMATION ABOUT THE  
SAFETY REVERSING SENSOR  
WARNING  
The safety reversing sensor must be connected and  
aligned correctly before the garage door opener will  
move in the down direction. This is a required safety  
device and cannot be disabled.  
Without a properly working safety reversing sensor,  
persons (particularly children) could be injured or killed  
by a closing garage door. Read and follow all  
instructions.  
To protect small children, install the safety reversing  
sensor so that the beam will be no higher than 4"-6"  
above the garage floor.  
When properly connected and aligned, the safety  
reversing sensor will detect an obstacle in the path of its  
electronic beam. The sending eye (with an orange  
indicator light) transmits an invisible light beam to the  
receiving eye (with a green indicator light). If an  
obstruction breaks the light beam while the door is  
closing, the door will stop and reverse to full open  
position, and the opener light will flash for 5 seconds.  
Disconnect power to the garage door opener before  
installing the safety reversing sensor.  
If it is necessary to mount the units on the wall, the  
brackets must be securely fastened to a solid surface such  
as the wall framing. Extension brackets (see Accessories)  
are available if needed. If installing in masonry  
construction, add a piece of wood at each location to  
avoid drilling extra holes in masonry if repositioning is  
necessary.  
The units must be installed inside the garage so that the  
sending and receiving eyes face each other across the  
door, between 4-6" above the floor. Either can be  
installed on the left or right of the door as long as the sun  
never shines directly into the receiving eye lens.  
The invisible light beam path must be unobstructed. No  
part of the garage door (or door tracks, springs, hinges,  
rollers or other hardware) may interrupt the beam while  
the door is closing.  
The mounting brackets are designed to clip onto the  
garage door track without additional hardware.  
Sensor Beam  
4-6" max.  
Sensor Beam  
4-6" max.  
above floor  
above floor  
Invisible Light Beam  
Protection Area  
Facing the door from inside the garage  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 4  
Install the Safety Reversing Sensor  
(Receiving and Sending Eyes)  
Installing the Brackets  
DOOR TRACK MOUNT (Right Side)  
Figure 1  
Be sure power to the opener is disconnected. Install  
and align the brackets so the sensors will face each other  
across the garage door, with the beam from 4 – 6" above  
the floor.  
Door  
Track  
Lip  
They may be installed in one of three ways, as follows.  
Indicator  
light  
Garage door track installation (preferred):  
• Slip the curved arms over the rounded edge of each  
door track, with the curved arms facing the door. Snap  
into place against the side of the track. It should lie  
flush, with the lip hugging the back edge of the track, as  
shown in Figure 1.  
Sensor  
Bracket  
Lens  
If your door track will not support the bracket securely,  
wall installation is recommended.  
Wall installation:  
WALL MOUNT (Right Side)  
Figure 2  
• Place the bracket against the wall with curved arms  
facing the door. Be sure there is enough clearance for  
the sensor beam to be unobstructed.  
Optional  
Extension  
Bracket  
Inside  
Garage  
Wall  
(See Accessories)  
• If additional depth is needed, an extension bracket (see  
Accessories) or wood blocks can be used.  
(Provided with  
Extension Bracket)  
• Use bracket mounting holes as a template to locate and  
drill (2) 3/16" diameter pilot holes on the wall at each  
side of the door, from 4–6" above the floor.  
• Attach brackets to wall with lag screws (not provided).  
• If using extension brackets or wood blocks, adjust right  
and left assemblies to the same distance out from the  
mounting surface. Make sure all door hardware  
obstructions are cleared.  
Sensor  
Bracket  
(Provided with  
Extension  
Bracket)  
Indicator  
Lens  
light  
Floor installation:  
• Use wood blocks or extension brackets (see  
Accessories) to elevate sensor brackets so the lenses  
will be 4-6" above the floor.  
FLOOR MOUNT (Right Side)  
Figure 3  
Lens  
Sensor  
Bracket  
Indicator  
light  
• Carefully measure and place right and left assemblies at  
the same distance out from the wall. Be sure all door  
hardware obstructions are cleared.  
(Provided with  
Extension Bracket)  
• Fasten to the floor with concrete anchors as shown.  
Attach with  
concrete anchors  
(not provided)  
(Provided with  
Extension  
Bracket)  
Optional  
Extension  
Bracket  
Inside  
Garage  
Wall  
(See Accessories)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 4 (Continued)  
Install the Safety Reversing Sensor  
Mounting and Wiring the Safety Sensors  
Figure 4  
• Slide a 1/4"-20x1/2" carriage bolt head into the slot on  
each sensor. Use wing nuts to fasten sensors to brackets,  
with lenses pointing toward each other across the door.  
Be sure the lens is not obstructed by a bracket  
extension. See Figure 4.  
Wing nut  
• Finger tighten the wing nuts.  
1/4"-20x1/2"  
Carriage bolt  
Lens  
Recommended Wire Routing  
1. Using insulated staples, run the wires from both  
sensors to the rail at the door header (see Figure 5).  
Hardware Shown Actual Size  
2. Cross and twist the two wires where they meet the rail  
(see inset A). Run the wires inside the channels at the  
top of the rail, along each side, to the power unit and  
pull taut (see inset B). Do not use the lower (trolley)  
channels.  
1/4"-20x1/2"  
Carriage Bolt  
Wing Nut  
Staples  
NOTE: If your access door is near the garage door,  
you may choose to install the door control at this time  
and run the door control wire along the rail with the  
sensor wires. Use one rail channel for the door control  
wire and the other channel for both sensor wires. If  
you choose this option, follow instructions 1-3  
on page 17 now.  
3. Thread the wires through the tabs on top of the drive  
shaft cover.  
A
Header  
Wall  
4. With your screwdriver tip, tuck the wires snugly into  
the rail channels. You will complete the wiring in  
Installation Step 7.  
Sensor  
Wire  
Twist  
Wires  
Sensor  
Wire  
Header  
Bracket  
Rail  
Channel  
Figure 5  
1. Run wires from sensors to end of rail  
at the door header. Cross & twist here to  
help contain wires in channels on top of rail.  
B
Bell Wire  
2. Run wires along channels  
to power unit and pull taut.  
3. Thread wires through tabs  
on top of Drive Shaft Cover.  
4. With screwdriver blade,  
tuck wires snugly into channels.  
Foam  
Packaging  
Carton  
Sensor  
Invisible Light Beam  
Protection Area  
Sensor  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 5  
Position the Opener  
CAUTION  
To prevent damage to steel, aluminum, fiberglass or  
glass panel doors, do not rest the opener on the door  
without using a 2x4.  
Follow instructions which apply to your door  
type as illustrated.  
SECTIONAL Door or  
ONE-PIECE Door with Track  
A 2x4 laid flat is convenient for setting an ideal door-  
to-rail distance.  
2x4  
Rail  
• Raise the opener onto a stepladder.  
You will need help at this point if the ladder is not tall  
enough.  
Foam  
Packaging  
• Open the door all the way and place a 2x4 laid flat on  
the top section beneath the rail.  
Door  
If the top panel hits the trolley when you raise the door,  
pull down on the trolley release arm to disconnect the  
inner and outer sections. The trolley can remain  
disconnected until Step 12 is completed.  
Trolley  
Trolley  
Release Arm  
ONE-PIECE Door without Track  
Header  
Bracket  
• With the door fully open and parallel to the floor,  
measure the distance from the floor to the top of the  
door.  
Top of Opener  
• Using a stepladder as a support, raise the opener to the  
same distance as the door from the floor (it will be at a  
slight angle as shown).  
Foam  
Packaging  
Top of Door  
• The top of the door should be level with the top of the  
opener. Do not position the opener more than 3" above  
this point.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 6  
Hang the Opener  
WARNING  
The opener could fall and injure someone if it is not  
properly secured. Fasten the opener securely to  
structural supports of the garage.  
Two representative installations are shown. Yours  
may be different. Hanging brackets should be angled,  
Figure 1, to provide rigid support. On finished ceilings,  
Figure 2, attach a sturdy metal bracket to structural  
supports before installing the opener. The bracket and  
fastening hardware are not supplied.  
Figure 1  
Structural  
Supports  
Measure the distance from each side of the opener to  
the structural support.  
• Cut both pieces of the hanging bracket to required  
lengths.  
Lag Screws  
5/16"x1-7/8"  
Drill 3/16" pilot holes in the structural supports.  
Measure  
Distance  
• Attach one end of each bracket to a support with  
5/16"x1-7/8" lag screws.  
CONTROL  
5/16"-18x7/8"  
Hex Screws  
5/16" Lock Washers  
5/16"-18 Nuts  
CENTER  
• Fasten the opener to the hanging brackets with  
5/16" - 18x7/8" screws, lock washers and nuts.  
• Check to make sure the rail is centered over the door  
(or in line with the header bracket if the bracket is not  
centered above the door).  
Preferred Range of  
Bracket Placement  
• Remove the 2x4. Operate the door manually. If the  
door hits the rail, raise the header bracket.  
Figure 2  
— FINISHED CEILING —  
Hardware Shown Actual Size  
Bracket  
(Not Supplied)  
Hidden  
Support  
Lag Screw  
5/16"-18 x 1-7/8"  
Lag Screws  
5/16"x1-7/8"  
(Not Supplied)  
5/16"-18x7/8" Screw  
5/16" Lock Washer  
5/16"-18 Nut  
Hex Screw  
5/16"- 18 x 7/8"  
5/16"-18x7/8" Screw  
5/16" Lock Washer  
5/16"-18 Nut  
Lockwasher 5/16"  
Nut 5/16" - 18  
CONTROL  
CENTER  
Preferred Range of  
Bracket Placement  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 7  
WARNING  
Install the Door Control  
and Connect all Wiring  
DO NOT CONNECT TO LIVE ELECTRICAL WIRING. CONNECT  
ONLY TO 24 VOLT LOW VOLTAGE WIRES. CONNECTION TO  
LIVE WIRES OR HIGHER VOLTAGE MAY CAUSE SERIOUS  
INJURY FROM SHOCK, BURN OR ELECTROCUTION.  
Locate the door control within sight of the door at a minimum  
height of 5 feet where small children cannot reach, and away  
from all moving parts of the door and door hardware.  
The door control is typically attached directly to the wall. If  
installing into drywall, drill 5/32" holes and use the anchors  
provided. For pre-wired installations (as in new home  
construction), the multi-function door control can be mounted  
to a standard single gang box.  
Children operating or playing with a garage door opener can  
injure themselves or others. The garage door could close and  
cause serious injury or death. Do not allow children to operate  
the push button or the remote control transmitter.  
A moving garage door could injure someone under it. Activate  
the opener only when the door is properly adjusted, you can  
see it clearly, and there are no obstructions to door travel.  
1. Strip 1/4" of insulation from one end of the bell wire and  
connect it to the two screw terminals on the back of the door  
control by color: white to 2 and white/red to 1. (Fig. 1)  
Do NOT connect the power and operate the opener at  
this time. See Step 9 on page 18.  
2. Lighted door control: Fasten to wall with 6ABx1-1/2" self-  
tapping screws.  
Outside Keylock connections (see Accessories)  
Multi-function: Remove the white cover by gently pushing  
both thumbs against upper corners of cover on the back side  
of the door control (Fig. 2). Fasten with 6ABx1-1/4" self-  
tapping screws (standard installation) or 6-32x1" machine  
screws (pre-wired installation) as follows: (Fig. 3)  
• Install bottom screw, allowing 1/8" to protrude from the wall.  
• Position bottom of door control over screw head and adjust  
for snug fit.  
To opener terminal screws: white to 2; white/red to 1  
Figure 1  
Figure 2  
Terminal  
Screws  
WHT  
2
RED WHT  
RED WHT  
1
2
1
2
RED  
1
• Install top screw with care to avoid cracking plastic  
housing. Do not overtighten.  
REMOVE COVER  
Multi-Function  
Door Control  
Lighted  
Door Control  
• Replace cover by inserting bottom tabs and snapping into  
place. To remove cover after mounting, gently pry at top  
with paper clip or small flat head screwdriver.  
Standard  
installation  
NOTE: After installation, a green indicator light behind the  
cover will indicate proper connection. If not lit, the Lock and  
Light features will not function (reverse wires to correct).  
LOCK  
LIGHT  
3. Standard installation only: Run bell wire up wall and  
across ceiling to opener. Use insulated staples to secure wire  
in several places. Be careful not to pierce the wire with a  
staple, creating a short. If your access door is near the  
garage door, you may run this wire with the Safety Reversing  
Sensor wires along the top of the rail. See page 14.  
PRE-WIRED INSTALLATION  
To Replace,  
Insert Bottom Tabs First  
Figure 3  
LOCK  
LIGHT  
4. Remove Control Center door on right panel of opener to  
access the terminal screws.  
24 Volt  
To Replace,  
Insert Bottom Tabs First  
2-Conductor Bell Wire  
5. Thread all wires through the opening at the base of the drive  
shaft cover (Fig. 4).  
6. Insert the remaining wire through the hole in the power unit  
and strip 1/4" of insulation from each set of wires.  
7. Connect door control wire to the opener terminal screws:  
white to 2 and white/red to 1.  
To  
Sensors  
To  
Door  
Control  
Figure 4  
WIRING TO  
CONTROL CENTER  
8. Connect sensor wires to the opener terminal screws: white to  
2 and white/black to 3.  
9. Attach the User Safety Instruction label to the wall near the  
door control, and the Maintenance Instruction label in a  
prominent location on the inside of the garage door.  
1. INSERT WIRES  
THROUGH  
OPENING IN  
DRIVE SHAFT  
COVER  
Terminal  
Screws  
Page 28 explains how to operate the opener using the door  
control.  
2. PUSH WIRING  
THROUGH HOLE IN  
CHASSIS  
(ABOVE CONTROL  
CENTER) AND  
CONNECT TO  
1
2
3
Control  
Center  
Hardware Shown Actual Size  
OPENER TERMINAL  
SCREWS  
Door Control  
Connections  
(dotted line)  
Sensor  
Connections  
6ABx1-1/2" Screw  
Lighted Door Control Button  
Insulated  
Staples  
1
2
3
Dry Wall  
Anchors  
6AB x 1-1/4" Screw  
Multi-function (std installation)  
6-32 x 1" Screw  
Multi-function (pre-wired)  
OPENER TERMINAL SCREWS  
(In Control Center)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 8  
Electrical Requirements  
WARNING  
To prevent electrocution or fire, installation and wiring  
must be in compliance with local electrical and building  
codes.  
To reduce the risk of electric shock, your garage door  
opener has a grounding type plug with a third grounding  
pin. This plug will only fit into a grounding type outlet.  
Do NOT use an extension cord, 2-wire adapter, or change  
the plug in any way to make it fit your outlet.  
If the plug doesn't fit into the outlet you have, contact a  
qualified electrician to install the proper outlet.  
To avoid installation difficulties,  
do not run the opener until Step 9 below.  
If permanent wiring is required by your local code,  
refer to the following procedure:  
Right  
Wrong  
WARNING  
To prevent electrocution, remove power from the  
garage door opener and from the circuit you plan to  
use for the permanent connection.  
Permanent Wiring  
Connection  
To make a permanent connection through the 7/8" diam.  
hole in the top of the opener (according to local code):  
Ground Tab  
• Remove the opener cover screws and set the cover aside.  
• Remove the attached 3-prong cord.  
Green  
Ground Screw  
Ground Wire  
• Connect the black (line) wire to the screw on the brass  
terminal; the white (neutral) wire to the screw on the  
silver terminal; and the ground wire to the green  
ground screw. The opener must be grounded.  
Black  
Wire  
• Reinstall the cover.  
White Wire  
BlackWire  
Trouble Shooting  
Installation Step 9  
Complete Safety Reversing Sensor  
Installation  
1. If the sending eye indicator light does not glow  
steadily after installation, check for:  
• Electric power to the opener.  
• A short in the white or white/black wires. These can  
occur under staples or at screw terminal connections.  
Aligning the Safety Sensors  
Plug in the opener. The indicator lights in both the  
sending and receiving eyes will glow steadily if wiring  
connections and alignment are correct.  
• Incorrect wiring between sensors and opener.  
• A broken wire.  
2. If the sending eye indicator light glows steadily but the  
The sending eye orange indicator light will glow  
regardless of alignment or obstruction. If the green  
indicator light in the receiving eye is off, dim, or  
flickering (and the invisible light beam path is not  
obstructed), alignment is required.  
receiving eye indicator light doesn't:  
• Check alignment.  
• Check for an open wire to the receiving eye.  
3. If the receiving eye indicator light is dim, realign  
either sensor.  
• Loosen the sending eye wing nut and re-adjust, aiming  
directly at the receiving eye. Lock in place.  
NOTE: When the invisible beam path is obstructed or  
misaligned while the door is closing, the door will  
reverse. If the door is already open, it will not close. The  
opener lights will flash 10 times. (If bulbs are not  
installed, 10 clicks are audible.) See page 12.  
• Loosen the receiving eye wing nut and adjust sensor  
vertically and/or horizontally until it receives the  
sender’s beam. When the green indicator light glows  
steadily, tighten the wing nut.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 10  
Install the Lights and Lens  
100 Watt Max.  
Light Bulb  
• Install a 100 watt maximum light bulb in each socket.  
The lights will turn ON and remain lit for  
approximately 4-1/2 minutes when power is connected.  
Then the lights will turn OFF.  
CONTROL  
CENTER  
Top Lens Slot  
• Insert bottom lens tabs into slots on chassis and tilt  
towards chassis to engage top tabs, then drop down  
gently into place. (See illustration.)  
Top Lens Tab  
• To remove, lift lens up and gently tilt slightly outward  
and down, then pull out to clear bulbs. Use care to  
avoid snapping off bottom lens tabs.  
Light Socket  
Bottom Lens Slot  
Bottom Lens Tab  
• If the bulbs burn out prematurely, replace with standard  
neck Garage Door Opener bulbs. (Fluorescent bulbs are  
not recommended because of possible interference with  
receiver/transmitter signals.)  
CONTROL  
CENTER  
Lens  
Chassis  
Insert Bottom Lens Tabs First  
Installation Step 11  
Attach the Manual Release  
Rope and Handle  
WARNING  
Do not use the red handle to pull the door open or  
closed. The rope knot could become untied and you  
could fall. Use the manual release only to disengage the  
trolley and, if possible, only when the door is closed.  
Garage doors are heavy. If the door is open when the  
handle is pulled, the door could close inadvertently if it is  
not properly balanced. Serious injury may result to  
persons under the door. Make sure the doorway is clear  
of persons and obstructions before pulling handle when  
door is open.  
Trolley  
Overhand  
Knot  
Trolley  
Rope  
Release Arm  
Thread one end of the rope through the hole in the top  
of the red handle so “NOTICE” reads right side up as  
shown. Secure with an overhand knot at least 1" from  
the end of the rope to prevent slipping.  
NOTICE  
Manual  
Release Handle  
Overhand  
Knot  
• Thread the other end of the rope through the hole in the  
release arm of the outer trolley.  
• Adjust rope length so the handle is 6 feet above the  
floor. Secure with an overhand knot .  
If it is necessary to cut the rope, heat seal the cut end  
with a match or lighter to prevent unraveling.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 12  
WARNING  
Fasten Door Bracket  
To prevent damage to steel, aluminum, fiberglass or  
glass panel doors, always reinforce the inside of the door  
both vertically and horizontally with an angle iron.  
Follow instructions which apply to your door type  
as illustrated below or on page 21.  
A horizontal brace should be long enough to be secured to 2 vertical supports. A vertical brace should cover the  
height of the top panel.  
The illustration shows one piece of angle iron as the horizontal brace. For the vertical brace, 2 pieces of angle iron  
are used to create a U-shaped support. The best solution is to check with your garage door manufacturer for an  
opener installation door reinforcement kit.  
SECTIONAL Door Installation Procedure  
Header  
Bracket  
Horizontal and vertical reinforcement  
is needed for lightweight garage doors  
(fiberglass, aluminum, steel,  
doors with glass panel, etc).  
Figure 1  
Vertical  
Reinforcement  
Vertical  
Guideline  
Door  
Bracket  
Location  
UP  
Carriage Bolt  
5/16"-18x2-1/2"  
Vertical  
Guideline  
Door  
Bracket  
Lock  
Washer  
5/16"  
Nut  
5/16"-18  
Figure 2  
Inside Edge  
of Door or  
Reinforcement Board  
UP  
• Center the door bracket on the previously marked  
vertical guideline used for the header bracket  
Door Bracket  
installation. Note the correct UP placement, as  
stamped inside the bracket.  
• Position the bracket on the face of the door within the  
following limits:  
Hardware Shown Actual Size  
A) The top edge of the bracket 2-4" below the top edge  
of the door.  
B) The top edge of the bracket directly below any  
structural support across the top of the door.  
Nut 5/16" - 18  
Lockwasher 5/16"  
• Mark and drill 5/16" left and right fastening holes.  
Secure the bracket as shown in Figure 1 if there is  
vertical reinforcement.  
If your installation doesn't require vertical reinforcement  
but does need top and bottom fastening holes for the door  
bracket, fasten as shown in Figure 2.  
Carriage Bolt  
5/16"-18 x 2-1/2"  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All ONE-PIECE Door Installation Procedure  
Please read and comply with the warnings and reinforcement instructions on page 20. They apply  
to one-piece doors also.  
Header Wall  
Finished Ceiling  
2x4 Support  
Horizontal and vertical  
Header  
Bracket  
reinforcement is needed for  
lightweight garage doors  
(fiberglass, aluminum, steel,  
door with glass panel, etc.).  
(Not Provided)  
Door  
Bracket  
Vertical  
Centerline of  
Garage Door  
Inside Edge  
of Door or  
Reinforcement Board  
Door  
Bracket  
• Center the bracket on the inside face of the door, in line  
with the header bracket as shown. Make either the left  
and right, or the top and bottom holes.  
Hardware Shown Actual Size  
• Drill 5/16" pilot holes and fasten the door bracket with  
hardware supplied.  
Nut 5/16" - 18  
Lockwasher 5/16"  
Carriage Bolt  
5/16"-18 x 2-1/2"  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Step 13  
Connect Door Arm to Trolley  
Follow instructions which apply to your door type  
as illustrated below and on page 23.  
SECTIONAL Doors Only  
Make sure garage door is fully closed. Pull the emergency release handle to disconnect the outer trolley from the  
inner trolley. Slide the outer trolley back (away from the door) about 2" as shown in Figures 1, 2 and 3.  
Figure 1:  
Figure 2:  
Fasten straight door arm section to outer trolley with  
the 5/16"x1" clevis pin. Secure the connection with a  
ring fastener.  
Bring arm sections together. Find two pairs of holes  
that line up and join sections. Select holes as far apart  
as possible to increase door arm rigidity.  
• Fasten curved section to the door bracket in the same  
way, using the 5/16"x1-1/4" clevis pin.  
Figure 2  
Figure 1  
Hole Alignment Alternative  
Hardware Shown Actual Size  
Figure 3:  
If holes in curved arm are above holes in straight arm,  
disconnect straight arm. Cut about 6" from the solid  
end. Reconnect to trolley with cut end down as shown.  
• Bring arm sections together.  
• Find two pairs of holes that line up and join with  
screws, lock washers and nuts.  
Figure 3  
Proceed to Adjustment Step 1, page 24.  
Trolley will re-engage automatically when the  
opener is operated.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All ONE-PIECE Doors  
Assemble the Door Arm:  
Fasten the straight and curved door arm sections  
together to the longest possible length (with a 2 or 3  
hole overlap).  
• With the door closed, connect the straight door arm  
section to the door bracket with the 5/16"x1-1/4"  
clevis pin.  
• Secure with a ring fastener.  
Adjustment Procedures for One-Piece Doors  
On one-piece doors, before connecting the door arm to the trolley the travel limits must be adjusted. Limit adjustment  
screws are located on the right side panel as shown on page 24. Follow adjustment procedures below.  
Open Door Adjustment:  
Decrease UP Travel Limit  
Closed Door Adjustment:  
Decrease DOWN Travel Limit  
• Turn the UP limit adjustment screw counter-clockwise  
5 1/2 turns.  
• Turn the DOWN limit adjustment screw clockwise  
5 complete turns.  
• Press the Door Control push bar. The trolley will  
travel to the fully open position.  
• Press the Door Control push bar. The trolley will travel  
to the fully closed position.  
• Manually raise the door to the open position (parallel  
to the floor), and lift the door arm to the trolley. The  
arm should touch the trolley just in back of the door  
arm connector hole. Refer to the fully open  
trolley/door arm positions in the illustration. If the arm  
does not extend far enough, adjust the limit further.  
One full turn equals 2" of trolley travel.  
• Manually close the door and lift the door arm to the  
trolley. The arm should touch the trolley just ahead of  
the door arm connector hole. Refer to the fully closed  
trolley/door arm positions in the illustration. If the arm  
is behind the connector hole, adjust the limit further.  
One full turn equals 2" of trolley travel.  
Connect the Door Arm to the Trolley:  
Close the door and join the curved arm to the connector hole in the trolley with the remaining clevis pin. It may be  
necessary to lift the door slightly to make the connection.  
• Secure with a ring fastener.  
• Run the opener through a complete travel cycle. If the door has a slight "backward" slant in full open position as shown  
in the illustration, decrease the UP limit until the door is parallel to the floor.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
Adjustment Section: Pages 24 – 26  
Adjustment Step 1  
Adjust the UP and DOWN Limits  
Do not make any limit adjustments until the safety  
reversing sensors are completely installed.  
WARNING  
Improper adjustment of the travel limits will interfere with  
the proper operation of the safety reverse system. The  
door might not reverse properly when required and could  
seriously injure or kill someone under it. Test the safety  
reverse system monthly, and following all adjustments to  
the travel limits. See page 26.  
Limit adjustment settings regulate the points at which the  
door will stop when moving up or down.  
The door will stop in the up direction if anything  
interferes with door travel. The door will reverse in the  
down direction if anything interferes with the door travel  
(including binding or unbalanced doors).  
To operate the opener, press the Door Control push bar or  
button. Run the opener through a complete travel cycle.  
+
1
2
3
• Does the door open and close completely?  
8
8
1
1
7
7
3
3
5
5
Kg  
+
K
g
• Does the door stay closed and not reverse  
unintentionally when fully closed?  
Travel Limit  
Adjustment  
Screws  
If your door passes both of these tests, no limit  
adjustments are necessary unless the reversing test fails  
(see page 26).  
Right Side Panel  
Adjustment procedures are outlined below. Run the  
opener through a complete travel cycle after each  
adjustment.  
Adjust UP Travel  
+
LIMIT ADJUSTMENT  
LABEL  
Repeated operation of the opener during adjustment  
procedures may cause the motor to overheat and shut off.  
Simply wait 15 minutes and try again.  
Adjust DOWN Travel  
+
Read the procedures carefully before proceeding to  
Adjustment Step 2. Use a screwdriver to make limit  
adjustments.  
How and When to Adjust the Limits  
If the door does not open completely but opens at least  
five feet:  
If the opener reverses in fully closed position:  
Decrease down travel. Turn the DOWN limit adjustment  
screw clockwise. One turn equals 2" of travel.  
Increase up travel. Turn the UP limit adjustment screw  
clockwise. One turn equals 2" of travel.  
If the door reverses when closing and there is no  
visible interference to travel cycle:  
If door does not open at least 5 feet: Adjust the UP  
(open) force as explained in Adjustment Step 2.  
If the opener lights are flashing, the Safety Reversing  
Sensors are either not installed, misaligned, or obstructed.  
See Troubleshooting, page 18.  
If the door does not close completely:  
Increase down travel. Turn the DOWN limit adjustment  
screw counterclockwise. One turn equals 2" of travel.  
Test the door for binding: Pull the manual release handle.  
Manually open and close the door. If the door is binding,  
call for garage door service. If the door is not binding or  
unbalanced, adjust the DOWN (close) force. See  
Adjustment Step 2.  
If door still won't close completely, try lengthening the  
door arm. (Page 22.)  
If you have adjusted the door arm to the maximum length  
and the door still will not close completely, lower the  
header bracket. See Installation Step 1, pages 8/9.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Step 2  
Adjust the Force  
WARNING  
Too much force on the door will interfere with the proper  
operation of the safety reverse system. The door might  
not reverse properly when required and could seriously  
injure or kill someone under it. Do not increase the force  
beyond the minimum amount required to close the door.  
Do not use the force adjustments to compensate for a  
binding or sticking garage door. Test the safety reverse  
system monthly, and following all adjustments to force  
levels. See page 26.  
Force adjustment controls are located on the right panel  
of the opener. Force adjustment settings regulate the  
amount of power required to open and close the door.  
The door will stop in the up direction if anything  
interferes with its travel. The door will reverse in the  
down direction if anything interferes with its travel  
(including binding or unbalanced doors).  
If the forces are set too light, door travel may be  
interrupted by nuisance reversals in the down direction  
and stops in the up direction. Weather conditions can  
affect the door movement, so occasional adjustment may  
be needed.  
The maximum force adjustment range is about 3/4 of a  
complete turn. Do not force controls beyond that point.  
Turn force adjustment controls with a screwdriver.  
+
1
2
3
8
8
1
1
7
7
3
3
5
5
K
g
K
g
+
Right Side  
Panel  
Force Adjustment  
Controls  
8
8
1
1
7
7
3
3
5
5
Kg  
Kg  
Force Adjustment Label  
How and When to Adjust the Forces  
Test the DOWN (close) force  
If the door doesn't open at least 5 feet:  
Grasp the door bottom when the door is about halfway  
through DOWN (close) travel. The door should reverse.  
Reversal halfway through down travel does not  
guarantee reversal on a one-inch obstruction. See  
page 26. If the door is hard to hold or doesn't reverse,  
decrease the DOWN (close) force by turning the control  
counterclockwise.  
Increase UP (Open) force by turning the control  
clockwise. Make small adjustments until door opens  
completely. Readjust the UP limit if necessary. After each  
adjustment, run the opener through a complete travel  
cycle.  
If the door reverses during the down (close) cycle and  
the opener lights aren't flashing:  
Make small adjustments until the door reverses normally.  
After each adjustment, run the opener through a complete  
cycle.  
Increase DOWN (close) force by turning the control  
clockwise. Make small adjustments until the door  
completes a close cycle. After each adjustment, run the  
opener through a complete travel cycle. Do not increase  
the force beyond the minimum amount required to  
close the door.  
Test the UP (open) force  
Grasp the door bottom when the door is about halfway  
through UP (open) travel. The door should stop. If the  
door is hard to hold or doesn't stop, decrease UP (open)  
force by turning the control counterclockwise.  
Make small adjustments until the door stops easily. After  
each adjustment, run the opener through a complete travel  
cycle.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Adjustment Step 3  
WARNING  
Test The Protector System®  
Without a properly working safety reversing sensor,  
persons (particularly children) could be seriously injured  
or killed if trapped by a closing garage door. Repeat this  
test once a month.  
• Press the remote control push button to open the door.  
• Place the opener carton in the path of the door.  
• Press the remote control push button to close the door.  
The door will not move more than an inch, and the  
opener light will flash for 5 seconds.  
Professional service is required if the opener closes the  
door when the safety reversing sensor is obstructed.  
The garage door opener will not close from a remote if  
the indicator light in either sensor is off (alerting you to  
the fact that the sensor is misaligned or obstructed).  
The garage door can be closed by pressing and holding  
the Door Control push bar or button until down travel is  
completed.  
Safety Reversing Sensor  
Safety Reversing Sensor  
Adjustment Step 4  
Test the Safety Reverse System  
WARNING  
Failure to test and adjust the safety reverse system may  
result in serious injury or death to persons trapped by a  
closing garage door. Repeat this test once a month and  
adjust as needed.  
Test  
• With the door fully open, place a one-inch board  
(or a 2x4 laid flat) on the floor, centered under the  
garage door.  
• Operate the door in the down direction. The door must  
reverse on striking the obstruction.  
Adjustment  
If the door stops on the obstruction, it is not traveling far  
enough in the down direction.  
• Increase the DOWN limit by turning the DOWN limit  
adjustment screw counterclockwise 1/4 turn.  
• Repeat the test.  
On a sectional door, make sure limit adjustments do  
not force the door arm beyond a straight up and down  
position. See the illustration on page 22.  
• When the door reverses on the one-inch board, remove  
the obstruction and run the opener through 3 or 4  
complete travel cycles to test adjustment.  
If the door will not reverse after repeated adjustment  
attempts, call for professional garage door service.  
One-Inch board (or a 2x4 laid flat)  
Important Safety Check  
Repeat Adjustment Steps 1-4 after:  
• Each adjustment of door arm length, force controls or  
limit controls.  
• Any repair to or adjustment of the garage door  
(including springs and hardware).  
• Any repair to or buckling of the garage floor.  
• Any repair to or adjustment of the opener.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
WARNING  
WARNING  
To reduce the risk of severe injury or death to persons:  
1. READ AND FOLLOW ALL INSTRUCTIONS.  
2. Do not permit children either to operate or to play with the opener. Keep remote control in a location  
inaccessible to children.  
3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in sight  
until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.  
4. Check safety reversal system monthly. See page 26. The garage door MUST reverse on contact with a one  
inch object (or a 2x4 board laid flat) placed on the floor. If an adjustment is made to one of the controls  
(either force or limits of travel), the other control may need to be adjusted also, and the safety reversal  
system must be checked. Failure to properly adjust the opener may result in severe injury or death.  
5. If possible, use the manual release only when the door is in a closed position. Caution should be taken  
whenever the disconnect cord is actuated with the door open. Weak or broken springs may cause the door to  
fall rapidly, causing injury or death to persons.  
6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3. An improperly balanced door may not  
reverse when required, and could result in severe injury or death. Repairs to cables, spring assemblies and  
other hardware must be made by a professional garage door person.  
7. Disconnect the electric power to the garage door opener before making any repairs or removing the covers.  
SAVE THESE INSTRUCTIONS  
Care of Your Opener  
The Remote Control Transmitter  
Force and Limit Adjustment Controls  
The opener must learn the code of any new remote  
control. Page 29 explains how to program your receiver  
and how to erase all codes if required. Self service of  
your receiver and remote controls is not recommended. If  
service is needed, call the toll-free number listed on the  
back page.  
+
8
8
1
1
7
7
3
3
5
5
Kg  
Kg  
+
The Transmitter Battery  
LIMIT CONTROLS  
FORCE CONTROLS  
The lithium battery should produce  
power for up to 5 years. To replace  
battery, pry open case with visor clip  
or screwdriver, as shown. Insert  
battery positive side up.  
Weather conditions may cause some minor changes in  
door operation requiring some re-adjustments,  
particularly during the first year of operation.  
Pages 24 and 25 refer to the limit and force adjustments.  
Only a screwdriver is required. Follow the instructions  
carefully.  
Dispose of your old battery properly.  
Repeat the safety reverse test (page 26) after any  
adjustment of limits or force.  
WARNING  
Keep batteries away from small children. If  
swallowed, promptly notify doctor.  
Maintenance Schedule  
Once a Month  
Repeat the safety reverse test. Make any necessary  
adjustments (See page 26).  
Manually operate door. If it is unbalanced or binding,  
call for professional garage door service.  
Once a Year  
Check to be sure door opens & closes fully. Adjust  
limits and/or force if necessary. (See pages 24 & 25.)  
Oil door rollers, bearings and hinges. The opener does  
not require additional lubrication. Do not grease the door  
tracks.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation of Your Opener  
Activate the opener with any of the following:  
• The Remote Control Transmitter. Hold push button  
WARNING  
down until the door starts to move.  
• The Door Control. Hold push bar or button down until  
the door starts to move.  
• The Outside Keylock or Keyless Entry.  
Weak or broken springs could allow an open door to fall  
(either rapidly or unexpectedly), resulting in serious  
injury, death or property damage. If possible, use the  
manual release rope and handle only when the door is  
fully closed.  
(See Accessories)  
When the opener is activated with the safety reversing  
sensor installed and correctly aligned:  
1. If open, the door will close. If closed, it will open.  
2. If closing, the door will reverse.  
To open the door manually:  
The door should be fully  
closed if possible. Pull down  
on the manual release handle  
(so that the trolley release  
arm snaps into a vertical  
position) and lift the door  
manually. The lockout  
3. If opening, the door will stop (allowing space for entry  
and exit of pets and for fresh air).  
4. If the door has been stopped in a partially open position,  
it will close.  
5. If obstructed while closing, the door will reverse.  
6. If obstructed while opening, the door will stop.  
Trolley  
Trolley  
ReleaseArm  
(in Manual  
Disconnect  
Position)  
NOTICE  
7. The garage door will reverse in the closing cycle, and  
the opener lights will blink for 5 seconds, when the  
invisible beam is broken. If fully open, the door will not  
close when the beam is broken. The sensor has no effect  
in the opening cycle.  
feature prevents the trolley  
from reconnecting auto-  
matically, and the door can be  
raised and lowered manually  
Lockout position  
(Manual disconnect)  
as often as necessary.  
If the sensor is not installed, or is not aligned correctly, the  
door won't close from any remote transmitter. However,  
you can close the door with the Door Control, the Outside  
Keylock, or Keyless Entry, if you activate them until down  
travel is complete. If you release them too soon, the door  
will reverse.  
Opener Lights will turn on under the following conditions:  
When the opener is initially plugged in; when the power is  
interrupted; when the opener is activated. It will turn off  
automatically after 4-1/2 minutes or provide constant light  
when the Light feature on the Multi-Function Door Control  
is activated. Bulb size is 100 watts maximum.  
To reengage the trolley: Pull  
the manual release handle  
toward the opener at a  
45° degree angle so that the  
trolley release arm is  
horizontal. The trolley will  
reconnect on the next UP or  
DOWN operation, either  
Trolley  
Trolley  
Release Arm  
Manual  
Release  
NOTICE  
Handle  
(Pull at 45° angle)  
Lights will also turn on when someone walks through the  
open garage door. With a Multi-Function Door Control, this  
feature may be turned off as follows: With the opener lights  
off, press and hold the light button for 10 seconds, until the  
light goes on and off again. To restore this feature, start with  
the opener lights on, then press and hold the light button for  
10 seconds.  
manually or by pressing the  
Door Control push bar  
or button.  
To reconnect  
Operation of the Door Controls: See additional programming features, next page.  
Lighted Door Control Button: Press to open or close the  
door.  
Lighted Push Bar – Door Control Panel: Press the white  
square to open or close the door.  
Repeat the procedure and the light will blink twice,  
resetting the timer to 2-1/2 minutes. Repeat again for a  
3-1/2 minute interval, etc., up to a maximum of four blinks  
and 4-1/2 minutes.  
Press again to reverse the door during the closing cycle or  
to stop the door while it's opening.  
Lock Feature – Door Control Panel: Designed to prevent  
operation of the door from portable remote controls.  
However, the door will open and close from the Door  
Control push bar, the Outside Keylock and the Keyless  
Entry Accessories.  
Light Feature – Door Control Panel: Press the Light  
button to turn the opener light on or off. If you turn it on  
and then activate the opener, the light will remain on for  
4-1/2 minutes. Press again to turn it off sooner. The Light  
button will not control the opener lights when the door is  
in motion.  
To Activate: Press and hold the Lock button for  
2 seconds. The push bar light will flash as long as the  
Lock feature is on.  
The 4-1/2 minute interval can be changed to 1-1/2, 2-1/2,  
or 3-1/2 minutes as follows: Press and hold the Lock  
button until the light blinks (about 10 seconds). A single  
blink indicates that the timer is reset to 1-1/2 minutes.  
To turn off: Press and hold the Lock button again for  
2 seconds. The push bar light will stop flashing. The  
Lock feature will also turn off whenever the “Smart”  
button on the opener panel is activated.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Children operating or playing with a garage door opener  
can injure themselves or others. The garage door could  
close and cause serious injury or death. Do not allow  
children to operate the door controls or remote controls.  
A moving garage door could injure or kill someone under  
it. Activate the opener only when you can see the door  
clearly, it is free of obstructions, and is properly adjusted.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Having a Problem?  
Situation  
Probable Cause & Solution  
1. Does the opener have electric power? Plug a lamp into the outlet. If it doesn't light, check the  
fuse box or the circuit breaker. (Some outlets are controlled by a wall switch.)  
The opener doesn't  
operate from either  
the door control or  
the remote control:  
2. Have you disabled all door locks? Review installation instruction warnings on Page 7.  
3. Is there a build-up of ice or snow under the door? The door may be frozen to the ground.  
Remove any restriction.  
4. The garage door spring may be broken. Have it replaced.  
5. Repeated operation may have tripped the overload protector in the motor. Wait  
15 minutes. Try again.  
Opener operates from  
the remote control, but  
not from the door  
control:  
1. Is the door control push bar lit? If not, Remove the bell wire from the opener terminal  
screws. Short the red and white terminals by touching both terminals at the same time with  
a piece of wire. If the opener runs, check for a faulty wire connection at the door control, a  
short under the staples, or a broken wire.  
2. Are the wiring connections correct? Review Installation Step 7, page 17.  
The door operates from 1. If your model has the Lock feature, turn it off.  
the door control, but not  
from the remote  
control:  
2. Is the wall push button flashing? Your opener needs to re-learn a remote control code.  
Refer to instructions on the opener panel.  
3. Does the battery test light glow when the remote control push button is pressed? If not,  
replace the battery.  
4. Program the receiver to match the remote control code.  
5. Repeat the receiver programming procedure with all remote controls.  
1. Check the battery test light. If the light is dim, replace the battery.  
2. Change the location of the remote control in your car.  
The remote control has  
short range:  
3. Check to be sure the antenna on the right side panel of opener extends fully.  
4. Some installations may have shorter range due to a metal door, foil backed insulation, or  
metal garage siding.  
Opener noise is  
disturbing in living  
quarters of home:  
If operational noise is a problem because of proximity of the opener to the living quarters, the  
Vibration Isolator Kit 41A3263 can be installed. This kit was designed to minimize vibration  
to the house and is easy to install.  
The garage door  
opens and closes by  
itself:  
1. Be sure that all remote control push buttons and battery indicator lights are off.  
2. Remove the bell wire from the door control terminals and operate from the remote control  
only. If this solves the problem, the door control is faulty (replace), or there is an  
intermittent short on the wire between the door control and the opener.  
The door doesn't open  
completely:  
1. If the door has been working properly but now doesn't open all the way, increase the up  
force. See page 25.  
2. Is something obstructing the door? Remove the obstruction or repair the door.  
3. If door opens at least 5 feet, the travel limits may need to be increased. One turn equals  
2 inches of travel. See page 24.  
Repeat the safety reverse test after the adjustment is complete.  
The door stops but  
doesn't close  
completely:  
Review the travel limits adjustment procedures on page 24.  
Repeat the safety reverse test after any adjustment of door arm length, close force or down  
limit.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Having a Problem? (continued)  
Situation  
Probable Cause & Solution  
The door opens but  
won't close:  
1. If the opener lights blink, check the safety reversing sensor. See page 18.  
2. If the opener lights do not blink and it is a new installation, check the down force. See  
Adjustment Step 2, page 25. For an existing installation, see below.  
Repeat the safety reverse test after the adjustment is complete.  
The door reverses for no  
apparent reason and  
opener lights don't  
blink:  
1. Is something obstructing the door? Pull the manual release handle. Operate the door  
manually. If it is unbalanced or binding, call for professional garage door service.  
2. Clear any ice or snow from the garage floor area where the door closes.  
3. Review the force adjustment procedures on page 25.  
4. If door reverses in the fully closed position, decrease the travel limits (page 24).  
Repeat the safety reverse test after adjustments to force or travel limits. The need for  
occasional adjustment of the force and limit settings is normal. Weather conditions in  
particular can affect door travel.  
The door reverses for no  
apparent reason and  
opener lights blink for  
5 seconds after  
Check the safety reversing sensor. Remove any obstruction or align the receiving eye. See  
page 18.  
reversing:  
The opener lights…  
don't turn on:  
Replace the light bulb(s) (100 watts maximum). Use a standard neck garage door opener bulb  
if regular bulb burns out.  
don't turn off:  
Is the Light feature on? Turn it off.  
The opener strains or  
maximum force is  
The door may be out of balance or the springs are broken. Close the door and use the manual  
release handle to disconnect the trolley. Open and close the door manually. A properly  
needed to operate door: balanced door will stay in any point of travel while being supported entirely by its springs. If  
it does not, disconnect the opener and call for professional garage door service. Do not  
increase the force to operate the opener.  
The opener motor  
hums briefly, then  
won't work:  
1. The garage door springs are broken. See above.  
2. If the problem occurs on the first operation of the opener, door may be locked. Disable the  
door lock.  
Repeat the safety reverse test after the adjustment is complete.  
The opener won't  
operate due to power  
failure:  
1. Use the manual release handle to disconnect the trolley. The door can be opened and closed  
manually. When power is restored, press the Door Control push bar and trolley will  
automatically reconnect (unless trolley is in lockout position.) See page 28.  
2. The Outside Quick Release accessory (for use on garages with no service door) disconnects  
the trolley from outside the garage in case of power failure.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts  
Rail Assembly Parts  
7
5
8
1
KEY PART  
NO.  
NO.  
DESCRIPTION  
2
3
1
41A4795  
Hardware bag (Includes  
sprocket coupling)  
2
3
4
5
12B569-1 Left rail bracket  
12B569-2 Right rail bracket  
4
81C168  
Rack  
41C4677  
Complete trolley  
assembly  
6
6
7
8
1D4828-1 One-piece T-rail  
41A4836  
25A18  
Drive sprocket kit  
Sprocket coupling  
Installation Parts  
3
5
6
4
1
4
LOCK  
LIGHT  
2
KEY PART  
NO. NO.  
7
DESCRIPTION  
8
1
2
3
4
5
41A5273-1 Multi-function door control panel  
41A4166-1 Lighted door control button  
29B137  
10A20  
41A5056-1 Single-function remote control housing  
(no circuit board)  
NOTICE  
Remote control visor clip  
3V2032 Lithium battery  
9
10  
6
41A5056-3 3-Channel remote control housing  
(no circuit board)  
CEILING MOUNT ONLY  
UP  
7
8
9
10  
11  
12  
217A238  
41A2828  
41A5047  
41A4353  
178B34  
2-Conductor bell wire - white & white/red  
Manual release rope & handle assy.  
Door bracket w/clevis pin & fastener  
Header bracket w/clevis pin & fastener  
Straight door arm section  
11  
12  
41A5034  
Safety sensor kit (receiving and sending  
eyes with 3' 2-conductor bell wire attached)  
13  
13  
14  
41A5266-1 Safety sensor brackets (2)  
178B35  
Curved door arm section  
NOT SHOWN  
41A4675-7 Opener hardware bag (includes hardware  
listed on page 3)  
14  
114A1947  
Owner's manual  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Repair Parts  
Power Unit Parts  
w
(Down)  
Contact  
LIMIT SWITCH ASSY.  
ew Drive  
Brown  
Wire  
2
1
D N  
94  
Grey  
Wire  
U P  
Drive  
Gear  
Center Limit  
Contact  
(Up)  
Yellow  
Contact  
Wire  
4
3
6
5
7
8c  
8b  
8a  
9
8d  
10  
8
11  
12  
13  
17  
14  
15  
16  
KEY PART  
NO. NO.  
KEY PART  
DESCRIPTION  
NO.  
NO.  
DESCRIPTION  
1
2
3
31D426  
41B4245  
30B363  
30B387  
12A373  
41A3150  
41D4671  
12D554  
41D4759  
144B41  
144B42  
20C14  
Drive shaft cover  
Line cord  
Capacitor – 1/2 HP  
Capacitor – 1/3 HP  
Capacitor bracket  
Terminal block w/screws  
Limit switch assembly  
Limit switch bracket  
Complete Motor Drive Assy., with  
22T Pulley  
9
41A4843  
41A4837  
41C4669  
41C4672  
Interrupter cup  
10  
11  
12  
13  
14  
Worm gear and retainer  
Wire harness assembly  
RPM sensor assembly  
4
5
6
7
8
8a  
8b  
8c  
8d  
41D4674-10E Receiver logic board assembly  
41D4839-6  
41D4839-8  
1C4840-4  
175C123  
108D47  
Cover – LM 1/2 HP  
Cover – LM 1/3 HP  
Control Center access door  
Light socket  
15  
16  
17  
Light lens  
28T Pulley  
Drive Belt  
Retainer Ring  
158A69  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Accessories Available For Your Opener  
Outside Quick Release:  
SECURITYSingle-Function  
Model 1702LMC  
Model 971LMC  
Remote Control:  
Required for a garage with NO access  
door. Enables homeowner to open  
garage door manually from outside by  
disengaging trolley.  
Includes visor clip.  
Model 972LMC SECURITY2-Channel  
Outside Keylock:  
Model 59LMC  
Model 88SD  
Remote Control:  
Operates the garage door automatically  
from outside when remote control is  
not handy.  
Includes visor clip.  
8 foot Complete Rail:  
Model 973LMC SECURITY3-Channel  
Remote Control:  
To allow an 8 foot door to open fully.  
Includes visor clip.  
Extension Brackets:  
Model 97LMC  
Model 98LMC  
SECURITY4-Channel  
Model 974LMC  
Model 970LMC  
Remote Control:  
(Optional) For safety sensor  
installation onto the wall or floor.  
Includes visor clip.  
SECURITY3-Channel Mini  
Remote Control:  
Motion Detecting Door Control  
Panel: Multi-function door control with  
motion sensor that automatically turns  
opener lights on for 5 minutes when it  
detects a person entering the garage. Sensor  
can be easily deactivated when desired.  
With key ring and Velco fastening  
strip.  
LOCK  
LIGHT  
Model 976LMC SECURITYKeyless Entry:  
Enables homeowner to operate garage door opener from outside by entering code on specially  
designed keyboard. Also can add a temporary pass code for visitors or service persons. This  
temporary code can be limited to a programmable number of hours or entries.  
To Add the Keyless Entry  
We recommend that you program your code before you  
You may also program the Keyless Entry from the  
Multi-Function Door Control, as follows:  
install the Keyless Entry. You will not need assistance,  
and you can test the reception at the mounting location  
before installation.  
1. With the door closed, enter the four digit code desired,  
then press and hold Enter.  
1. Choose a 4-digit code using numbers from 0 to 9  
(a number can be used more than once, for example,  
4, 0, 4, 1).  
2. Press and hold the light button on the door control.  
3. Press and hold the door control push bar.  
4. After the opener lights flash, release all buttons.  
2. Press the four buttons for the code, then press and hold  
the Enter button. The indicator light on the door opener  
panel will blink.  
3. Press and release the “Smart” (learn) button on the  
opener panel. After the opener lights flash, release the  
Enter button.  
Test by pressing the the code, then press Enter. The door  
should begin to move.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
Access Door/Outside Quick Release Accessory.........................................................................................................31, 34  
Electrical Safety Warnings......................................................................................................................................7, 18, 27  
Garage Door  
Testing for balance, binding and sticking.................................................................................................................3, 24, 27  
Determining high point of travel:  
Sectional door....................................................................................................................................................................8  
One-piece door..................................................................................................................................................................9  
Disabling existing locks ...................................................................................................................................................3, 7  
Force controls  
Adjustment procedures....................................................................................................................................................25  
Problems that might require force adjustments.........................................................................................................30, 31  
Safety warnings.........................................................................................................................................................25, 27  
Door hardware............................................................................................................................................3, 7, 8, 17, 27, 28  
Maintenance .............................................................................................................................................................7, 24-27  
Reinforcement requirements ....................................................................................................................................5, 20, 21  
Removing of all ropes ......................................................................................................................................................3, 7  
Possible door damage...............................................................................................................................................4, 15, 20  
Travel limits  
Adjustment procedures..............................................................................................................................................23, 24  
Problems that might require limit adjustments .........................................................................................................30, 31  
Safety warnings.........................................................................................................................................................24, 27  
Manual Release Rope & Handle  
Lockout feature .................................................................................................................................................................28  
Manual disconnect.......................................................................................................................................................28, 31  
Safety warnings.................................................................................................................................................7, 19, 27, 28  
Opener Terminals  
Door control connections ..................................................................................................................................................17  
Safety reversing sensor connections .................................................................................................................................17  
Outside Keylock accessory connections ...........................................................................................................................17  
Operational Noise  
Vibration noise (isolator kit) .............................................................................................................................................30  
Protector System®.........................................................................................................................................................12, 26  
Receiver & Remote Controls  
Programming the receiver.................................................................................................................................................29  
Erasing all codes................................................................................................................................................................29  
Safety warning...................................................................................................................................................................29  
Problems with remote control transmitter operation.........................................................................................................30  
Safety Reverse Test Procedure..........................................................................................................................................26  
Testing required.................................................................................................................................................7, 26, 30, 31  
Safety reverse system problems  
Securing header bracket to wall ........................................................................................................................................8  
Adjusting travel limits.....................................................................................................................................................24  
Applying excessive force on the door.............................................................................................................................25  
Buckling or uneven floor...................................................................................................................................................5  
Safety Warnings..........................................................................2, 3, 7, 8, 12, 15, 16, 17, 18, 19, 20, 24, 25, 26, 27, 28, 29  
User Instruction Label for Garage Wall ......................................................................................................................7, 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
35  
HOW TO ORDER  
REPAIR PARTS  
Selling prices will be furnished on request or parts will  
be shipped at prevailing prices and you will be billed  
accordingly.  
LIFT-MASTER SERVICE  
IS ON CALL  
OUR LARGE SERVICE ORGANIZATION  
SPANS AMERICA AND CANADA  
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE  
THE FOLLOWING INFORMATION:  
INSTALLATION AND SERVICE INFORMATION IS AS  
NEAR AS YOUR TELEPHONE SIX DAYS A WEEK.  
SIMPLY DIAL OUR TOLL FREE NUMBER:  
• PART NUMBER  
• PART NAME  
• MODEL NUMBER  
1-800-654-4736  
HOURS: (Central Standard Time)  
6:00 A.M. TO 7:00 P.M. Monday through Friday  
8:00 A.M. TO 6:00 P.M. Saturday  
ADDRESS ORDERS TO:  
THE CHAMBERLAIN GROUP, INC.  
Parts & Service Department  
2301 N. Forbes Boulevard, Suite 104  
Tucson, Arizona 85745  
For professional installation, parts and service,  
contact your local LIFT-MASTER/ CHAMBERLAIN  
dealer. Look for him in the Yellow Pages, or call our  
service number for a list of dealers in your area.  
SERVICE INFORMATION TOLL FREE NUMBER:  
1-800-654-4736  
LIFT-MASTER GARAGE DOOR OPENER ONE-YEAR LIMITED WARRANTY  
The Chamberlain Group, Inc. (“Seller”) warrants to the first retail purchaser of this product, for the residence in which this product is  
originally installed, that it will be free from any defect in materials and/or workmanship for a period of one year from the date of purchase.  
Additionally, the motor is fully warranted for the lifetime of the product for Model 2000SDC-R. The product must be used in complete  
accordance with Chamberlain’s instructions for installation, operation and care. The proper operation of this product is dependent on  
your compliance with the Owner’s Manual instructions regarding installation, operation, maintenance and testing. Failure to  
comply strictly with those instructions will void this warranty in its entirety. Please note that the safety reverse system, in order  
to operate properly with your garage door, must be adjusted and periodically tested in accordance with the Owner’s Manual.  
If, during the limited warranty period, it appears as though this product contains a defect which is covered by this limited warranty,  
CALL OUR TOLL FREE SERVICE NUMBER, BEFORE DISMANTLING THIS PRODUCT, AT (1-800-654-4736). Then send this  
product, pre-paid and insured, to our service center for warranty repair. You will be advised of shipping instructions when you call the  
toll free service number. Please include a brief description of the problem and a dated proof-of-purchase receipt with any product that  
is returned for warranty repair.  
Products returned to Seller for warranty repair, which upon receipt by Seller are confirmed to be defective and covered by this limited  
warranty, will be repaired or replaced (at Seller’s sole option) at no cost to you and returned pre-paid. Defective parts will be repaired  
or replaced with new or factory-rebuilt parts at Seller’s sole option.  
THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED  
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE, AND OF ANY OTHER  
OBLIGATIONS OR LIABILITY ON SELLER’S PART. THIS LIMITED WARRANTY DOES NOT COVER NON-DEFECT DAMAGE,  
DAMAGE CAUSED BY IMPROPER INSTALLATION, OPERATION OR CARE (INCLUDING, BUT NOT LIMITED TO ABUSE,  
MISUSE, FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE, OR ANY ALTERATIONS TO THIS  
PRODUCT), LABOR CHARGES FOR DISMANTLING OR REINSTALLING A REPAIRED OR REPLACED UNIT, REPLACEMENT  
OF BATTERIES AND LIGHT BULBS, OR UNITS INSTALLED FOR NON-RESIDENTIAL USE.  
THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH, OR RELATING TO, THE GARAGE DOOR OR GARAGE  
DOOR HARDWARE, INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS, DOOR ROLLERS, DOOR ALIGNMENT AND  
HINGES. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD  
RESULT IN A FEE TO YOU.  
UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES  
ARISING IN CONNECTION WITH THE USE OF, OR INABILITY TO USE, THIS PRODUCT. IN NO EVENT SHALL SELLER’S  
LIABILITY FOR BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE OR STRICT LIABILITY EXCEED THE  
COST OF THE PRODUCT COVERED HEREBY. NO PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN  
CONNECTION WITH THE SALE OF THIS PRODUCT.  
Some provinces do not allow the exclusion or limitation of consequential, incidental or special damages, so the above limitation or  
exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary  
from province to province.  
LIMITED WARRANTY ON MOTOR  
Model 2000SDC-R: The motor is fully warranted for the lifetime of the product to the first-time purchaser.  
Model 1000SDC-R: The motor is warranted to be free from any defect in materials and/or workmanship for a period of 36 full months  
(3 years) from the date of purchase.  
© 2000, The Chamberlain Group, Inc.  
114A1947F  
All Rights Reserved  
Printed in Mexico  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Beko Washer 914834 User Manual
Black Box Computer Hardware KV1720A User Manual
Black Box Network Card LBH1500A User Manual
Bosch Power Tools Router 0 601 617 061 User Manual
Bose Headphones AM299357 User Manual
Bose Video Gaming Accessories VG917 KST User Manual
Briggs Stratton Portable Generator 30255 User Manual
BRK electronic Carbon Monoxide Alarm FCD3N User Manual
Broilmaster Gas Grill H3XPK 1 User Manual
Canon All in One Printer 2270 User Manual