| Commercial Style Gas Cooktop   LOCATION REQUIREMENTS   PRODUCT MODEL NUMBERS   KGCU407V   KGCU462V   KGCU463V   KGCU467V   KGCU482V   KGCU483V   KGCU484V   IMPORTANT: Observe all governing codes and ordinances. Do not obstruct flow of   combustion and ventilation air.   It is the installer’s responsibility to comply with installation clearances specified on the   model/serial rating plate. The model/serial rating plate is located on the underside of the   cooktop burner base.   It is recommended that a 600 CFM or larger vent hood be installed above the cooktop.   It is not recommended that a microwave hood combination be mounted above the   cooktop.   The cooktop should be installed in a location away from strong draft areas, such as   windows, doors and strong heating vents or fans.   All openings in the wall or floor where cooktop is to be installed must be sealed.   Cabinet opening dimensions that are shown must be used. Given dimensions are   minimum clearances.   IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet   supplier to make sure that the materials used will not discolor, delaminate or sustain other   damage.   Type of Gas   Natural Gas:   This cooktop is design-certified by CSA International for   use with Natural gas or, after proper conversion, for use   with LP gas.   This cooktop is factory-set for use with Natural gas. To   convert to LP gas, see the Gas Conversion instructions   provided in the package containing literature. The model/   serial rating plate located on the left underside of the   cooktop burner base has information on the types of gas   that can be used. If the types of gas listed do not include   the type of gas available, check with the local gas supplier.   LP Gas conversion:   Conversion must be done by a qualified service technician.   PRODUCT DIMENSIONS   No attempt shall be made to convert the cooktop from the   gas specified on the model/serial rating plate for use with a   different gas without consulting the serving gas supplier. To   convert to LP gas, use the LP gas conversion kit provided   with the cooktop and see the “Gas Conversions” section.   C D Gas Supply Line   ꢀ Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the   cooktop location. A smaller size pipe on longer runs may   result in insufficient gas supply. With LP gas, piping or   tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas   suppliers determine the size and materials used in the   system.   NOTE: Pipe-joint compounds that resist the action of LP   gas must be used. Do not use TEFLON®† tape.   E Flexible metal appliance connector:   A B ꢀ If local codes permit, a new CSA design-certified, 4 - 5 ft   (122 - 152.4 cm) long, ⁵⁄₈" (1.6 cm) or ³⁄₄" (1.9 cm) I.D.,   flexible metal appliance connector may be used for   connecting the cooktop to the gas supply line.   A. 30" (76.2 cm) cooktop: 29⁷7⁄₈" (75.9 cm)   C. Model/serial rating plate (located on the   underside of the cooktop burner base)   D. Island trim or optional backguard   ⁄₈   7 36" (91.4 cm) cooktop: 35⁷⁄⁄₈₈" (91.1 cm)   7 48" (121.9 cm) cooktop: 47⁷⁄⁄₈₈" (121.6 cm)   ꢀ Must include a shutoff valve:   B. 36" (91.4 cm) long 3 prong grounding-type   power supply cord   E. 27   70.5 cm)   The supply line must be equipped with a manual shutoff   valve. This valve should be located in the same room but   external to the cooktop enclosure or cabinet. It should be   in a location that allows ease of opening and closing. Do   not block access to shutoff valve. The valve is for turning   on or shutting off gas to the cooktop.   A B B A C C G E A. Gas supply line   Side View of Cooktop   B. Shutoff valve “open” position   C. To cooktop   D F Electrical:   A. 27   70.5 cm)   E. 22" (55.9 cm)   F. 3⁵⁄₈" (9.2 cm)   G. 1" (2.6 cm)   A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit   is required. A time-delay fuse or circuit breaker is also   recommended. It is recommended that a separate circuit   serving only this cooktop be provided.   C. 7⁷⁄₁₆" (18.8 cm)   D. Gas inlet is located 1⁷⁄₈" (4.8 cm) from the back of   the cooktop burner base and 4⁷⁄₈" (12.4 cm) in   from left-hand side of the cooktop burner base.   †®TEFLON is a registered trademark of E.I. Du Pont De Nemours and   Company.   Page 1 of 2   Because Whirlpool Corporation policy includes a continuous commitment to improve   our products, we reserve the right to change materials and specifications without notice.   Dimensions are for planning purposes only. For complete details, see Installation   Instructions packed with product. Specifications subject to change without notice.   Ref. W10526088A   5/6/13   |