Dell Computer Drive R520 User Manual

Dell PowerEdge R520  
Owner's Manual  
Regulatory Model: E19S Series  
Regulatory Type: E19S001  
Contents  
8
1
About Your System  
Front-Panel Features And Indicators  
Figure 1. Front-Panel Features and Indicators  
Figure 2. Front-Panel Features and Indicators for a Software RAID System  
Item  
1
Indicator, Button, or  
Connector  
Icon  
Description  
Power-on indicator, power  
button  
The power-on indicator lights when the system power is  
on. The power button controls the power supply output to  
the system.  
NOTE: On ACPI-compliant operating systems, turning  
off the system using the power button causes the  
system to perform a graceful shutdown before power  
to the system is turned off.  
Used to troubleshoot software and device driver errors  
when using certain operating systems. This button can be  
pressed using the end of a paper clip.  
2
NMI button  
9
   
Item  
Indicator, Button, or  
Connector  
Icon  
Description  
Use this button only if directed to do so by qualified  
support personnel or by the operating system's  
documentation.  
3
System identification button  
The identification buttons on the front and back panels  
can be used to locate a particular system within a rack.  
When one of these buttons is pushed, the LCD panel on  
the front and the system status indicator on the back  
flashes blue until one of the buttons is pushed again.  
Press to toggle the system ID on and off. If the system  
hangs during POST, press and hold the system ID button  
for more than five seconds to enter BIOS progress mode.  
To reset the iDRAC (if not disabled in F2 iDRAC setup)  
press and hold for more than 15 seconds.  
4
Video connector  
Connects a VGA display to the system.  
5
6
LCD menu buttons  
LCD panel  
Allows you to navigate the control panel LCD menu.  
Displays system ID, status information, and system error  
messages. The LCD lights blue during normal system  
operation. The LCD lights amber when the system needs  
attention, and the LCD panel displays an error code  
followed by descriptive text.  
NOTE: If the system is connected to AC power and an  
error is detected, the LCD lights amber regardless of  
whether the system is turned on.  
7
8
USB connectors (2)  
Information tag  
Allows you to connect USB devices to the system. The  
ports are USB 2.0 compliant.  
A slide-out label panel, which allows you to record system  
information, such as Service Tag, NIC, MAC address, and  
so on as per your need.  
9
Hard drives (8)  
Up to eight 2.5 inch or 3.5 inch hot-swappable hard  
drives.  
Up to four 2.5 inch or 3.5 inch hot-swappable hard  
drives on software RAID systems.  
10  
11  
Optical drive (optional)  
One optional SATA DVD-ROM drive or DVD+/-RW drive.  
NOTE: DVD devices are data only.  
Dual slot hard-drive blanks  
(2)  
Hard-drive blanks for the empty hard-drive slots.  
NOTE: Dual slot hard-drive blanks are available only  
on software RAID systems. The blank hard-drive slots  
are not available for software RAID.  
10  
LCD Panel Features  
The system's LCD panel provides system information and status and error messages to indicate when the system is  
operating correctly or when the system needs attention. See LCD Error Messages for information about specific error  
codes.  
The LCD backlight lights blue during normal operating conditions and lights amber to indicate an error condition.  
The LCD backlight is off when the system is in standby mode and can be turned on by pressing either the Select,  
Left, or Right button on the LCD panel.  
The LCD backlight remains off if LCD messaging is turned off through the iDRAC utility, the LCD panel, or other tools.  
Figure 3. LCD Panel Features  
Item  
1
Button  
Left  
Description  
Moves the cursor back in one-step  
increments.  
2
3
Select  
Right  
Selects the menu item highlighted by  
the cursor.  
Moves the cursor forward in one-step  
increments.  
During message scrolling:  
Press once to increase scrolling  
speed  
Press again to stop  
Press again to return to default  
scrolling speed  
Press again to repeat the cycle  
Home Screen  
The Home screen displays user-configurable information about the system. This screen is displayed during normal  
system operation when there are no status messages or errors. When the system is in standby mode, the LCD backlight  
turns off after five minutes of inactivity if there are no error messages. Press one of the three navigation buttons (Select,  
Left, or Right) to view the Home screen.  
To navigate to the Home screen from another menu, continue to select the up arrow  
displayed, and then select the Home icon.  
until the Home icon  
is  
From the Home screen, press the Select button to enter the main menu.  
11  
   
Setup Menu  
NOTE: When you select an option in the Setup menu, you must confirm the option before proceeding to the next  
action.  
Option  
Description  
iDRAC  
Select DHCP or Static IP to configure the network mode. If Static IP is selected, the available  
fields are IP, Subnet (Sub), and Gateway (Gtw). Select Setup DNS to enable DNS and to view  
domain addresses. Two separate DNS entries are available.  
Set error  
Select SEL to display LCD error messages in a format that matches the IPMI description in the  
SEL. This is useful when trying to match an LCD message with an SEL entry.  
Select Simple to display LCD error messages in a simplified user-friendly description. See  
System Error Messages for a list of messages in this format.  
Set home  
Select the default information to be displayed on the LCD Home screen. See View Menu to see  
the options and option items that can be set as the default on the Home screen.  
View Menu  
NOTE: When you select an option in the View menu, you must confirm the option before proceeding to the next  
action.  
Option  
Description  
iDRAC IP  
Displays the IPv4 or IPv6 addresses for the iDRAC7. Addresses include DNS (Primary and  
Secondary), Gateway, IP, and Subnet (IPv6 does not have Subnet).  
MAC  
Displays the MAC addresses for iDRAC, iSCSI, or Network devices.  
Displays the name of the Host, Model, or User String for the system  
Displays the Asset tag or the Service tag for the system.  
Name  
Number  
Power  
Displays the power output of the system in BTU/hr or Watts. The display format can be  
configured in the Set home submenu of the Setup menu.  
Temperature  
Displays the temperature of the system in Celsius or Fahrenheit. The display format can be  
configured in the Set home submenu of the Setup menu.  
12  
   
Hard-Drive Indicator Patterns  
Figure 4. Hard-Drive Indicators  
1.  
2.  
hard-drive activity indicator (green)  
hard-drive status indicator (green and amber)  
NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side)  
does not function and remains off.  
Drive-Status  
Indicator Pattern  
Condition  
(RAID Only)  
Blinks green two  
times per second  
Identifying drive or preparing for removal  
Drive ready for insertion or removal  
Off  
NOTE: The drive status indicator remains off until all hard drives are initialized after the  
system is turned on. Drives are not ready for insertion or removal during this time.  
Blinks green, amber, Predicted drive failure  
and off  
Blinks amber four  
times per second  
Drive failed  
Blinks green slowly  
Steady green  
Drive rebuilding  
Drive online  
Blinks green three  
seconds, amber three  
seconds, and off six  
seconds  
Rebuild aborted  
13  
 
Back-Panel Features And Indicators  
Figure 5. Back-Panel Features and Indicators—Redundant Power Supply Unit Chassis  
Figure 6. Back-Panel Features and Indicators—Non-Redundant Power Supply Unit Chassis  
Item  
Indicator, Button, or  
Connector  
Icon  
Description  
1
2
PCIe expansion card slot 1  
Connects a PCI Express expansion card.  
Allows you to insert a vFlash media card.  
vFlash media card slot  
(Optional)  
3
4
iDRAC port (Optional)  
Dedicated management port for the iDRAC Ports Card.  
Connects a PCI Express expansion card.  
PCIe expansion card slots  
(3)  
5
6
7
Serial connector  
Connects a serial device to the system.  
Connects a VGA display to the system.  
Video connector  
Integrated 10/100/1000 Mbps NIC connector  
Ethernet connectors (2)  
Integrated 100 Mbps/1 Gbps/10 Gbps SFP+ connector  
8
USB connectors (2)  
Connect USB devices to the system. The ports are USB  
2.0-compliant.  
9
System identification  
connector  
Connects the optional system status indicator assembly  
through the optional cable management arm.  
10  
System identification button  
The identification buttons on the front and back panels  
can be used to locate a particular system within a rack.  
When one of these buttons is pushed, the LCD panel on  
14  
 
Item  
Indicator, Button, or  
Connector  
Icon  
Description  
the front and the system status indicator on the back blink  
until one of the buttons is pushed again.  
Press to toggle the system ID on and off. If the system  
hangs during POST, press and hold the system ID button  
for more than five seconds to enter BIOS progress mode.  
To reset the iDRAC (if not disabled in System Setup) press  
and hold for more than 15 seconds.  
11  
Power supply  
AC  
495 W, 750 W, 1100 W or 550 W  
(non-redundant),  
Or  
DC  
750 W or 1100 W  
NIC Indicator Codes  
Figure 7. NIC Indicator  
1.  
2.  
link indicator  
activity indicator  
Indicator  
Indicator Code  
The NIC is not connected to the network.  
Link and activity  
indicators are off  
Link indicator is  
green  
The NIC is connected to a valid network at its maximum port speed (1 Gbps or 10 Gbps).  
The NIC is connected to a valid network at less than its maximum port speed.  
Network data is being sent or received.  
Link indicator is  
amber  
Activity indicator is  
blinking green  
Power Indicator Codes  
Each AC power supply has an illuminated translucent handle and each DC power supply (when available) has an LED  
that serves as an indicator to show whether power is present or whether a power fault has occurred.  
15  
   
Figure 8. AC Power Supply Status Indicator  
1. AC power supply status indicator/handle  
Figure 9. DC Power Supply Status Indicator  
1. DC power supply status indicator  
Power Indicator  
Pattern  
Condition  
Not lit  
Green  
Power is not connected.  
The handle/LED indicator lights green indicating that a valid power source is connected to the  
power supply and that the power supply is operational.  
Flashing amber  
Indicates a problem with the power supply.  
CAUTION: When correcting a power supply mismatch, replace only the power supply with  
the flashing indicator. Swapping the opposite power supply to make a matched pair can  
result in an error condition and unexpected system shutdown. To change from a High  
Output configuration to a Low Output configuration or vice versa, you must power down  
the system.  
16  
Power Indicator  
Pattern  
Condition  
CAUTION: AC power supplies support both 220 V and 110 V input voltages with the  
exception of Titanium power supplies, which support only 220 V. When two identical  
power supplies receive different input voltages, they can output different wattages, and  
trigger a mismatch.  
CAUTION: If two power supplies are used, they must be of the same type and have the  
same maximum output power.  
CAUTION: Combining AC and DC power supplies is not supported and triggers a mismatch.  
Flashing green  
When hot-adding a power supply, this indicates that the power supply is mismatched with the  
other power supply (in terms of efficiency, feature set, health status, and supported voltage).  
Replace the power supply that has the flashing indicator with a power supply that matches the  
capacity of the other installed power supply.  
Power Indicator Codes For Non-Redundant Power Supply  
The non-redundant power supply has a status indicator and a self-diagnostic button. The self-diagnostic button is used  
to perform a quick health check on the non-redundant power supply of the system.  
Figure 10. Non-Redundant AC Power Supply Status Indicator and Self-Diagnostic Button  
1.  
2.  
self-diagnostic button  
non-redundant AC power supply status indicator  
Diagnostic Indicator Condition  
Pattern  
Not lit  
Power is not connected or power supply is faulty.  
17  
 
Diagnostic Indicator Condition  
Pattern  
Green  
A valid power source is connected to the power supply and the power supply is operational.  
Other Information You May Need  
WARNING: See the safety and regulatory information that shipped with your system. Warranty information may be  
included within this document or as a separate document.  
The Getting Started Guide provides an overview of setting up your system, and technical specifications. This  
document is available online at www.dell.com/support/manuals.  
The rack documentation included with your rack solution describes how to install your system into a rack, if  
required.  
Any media that ships with your system that provides documentation and tools for configuring and managing your  
system, including those pertaining to the operating system, system management software, system updates, and  
system components that you purchased with your system.  
For the full name of an abbreviation or acronym used in this document, see the Glossary at www.dell.com/support/  
manuals.  
NOTE: Always check for updates on www.dell.com/support/manuals and read the updates first because they often  
supersede information in other documents.  
18  
 
2
Using The System Setup And Boot Manager  
System Setup enables you to manage your system hardware and specify BIOS-level options.  
The following keystrokes provide access to system features during startup:  
Keystroke  
<F2>  
Description  
Enters the System Setup.  
Enters System Services, which opens the Dell Lifecycle  
Controller 2 (LC2). The Dell LC2 supports systems  
management features such as operating system  
<F10>  
deployment, hardware diagnostics, firmware updates, and  
platform configuration, using a graphical user interface.  
The exact LC2 feature set is determined by the iDRAC  
license purchased. For more information, see the Dell LC2  
documentation.  
Enters the BIOS Boot Manager or the Unified Extensible  
Firmware Interface (UEFI) Boot Manager, depending on  
the system's boot configuration  
<F11>  
.
Starts Preboot Execution Environment (PXE) boot.  
<F12>  
From the System Setup, you can:  
Change the NVRAM settings after you add or remove hardware  
View the system hardware configuration  
Enable or disable integrated devices  
Set performance and power management thresholds  
Manage system security  
You can access the System Setup using the:  
Standard graphical browser, which is enabled by default  
Text browser, which is enabled using Console Redirection  
To enable Console Redirection, in System Setup, select System BIOS Serial Communication screen Serial  
Communication, select On with Console Redirection.  
NOTE: By default, help text for the selected field is displayed in the graphical browser. To view the help text in the  
text browser, press <F1>.  
Choosing The System Boot Mode  
System Setup enables you to specify the boot mode for installing your operating system:  
BIOS boot mode (the default) is the standard BIOS-level boot interface.  
19  
   
UEFI boot mode is an enhanced 64-bit boot interface based on Unified Extensible Firmware Interface (UEFI)  
specifications that overlays the system BIOS.  
You must select the boot mode in the Boot Mode field of the Boot Settings screen of System Setup. Once you specify the  
boot mode, the system boots in the specified boot mode and you then proceed to install your operating system from that  
mode. Thereafter, you must boot the system in the same boot mode (BIOS or UEFI) to access the installed operating  
system. Trying to boot the operating system from the other boot mode will cause the system to halt at startup.  
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit  
operating systems do not support UEFI and can only be installed from the BIOS boot mode.  
NOTE: For the latest information on supported operating systems, go to dell.com/ossupport.  
Entering System Setup  
1. Turn on or restart your system.  
2. Press <F2> immediately after you see the following message:  
<F2> = System Setup  
If your operating system begins to load before you press <F2>, allow the system to finish booting, and then restart  
your system and try again.  
Responding To Error Messages  
If an error message is displayed while the system is booting, make a note of the message. For more information, see  
System Error Messages.  
NOTE: After installing a memory upgrade, it is normal for your system to display a message the first time you start  
your system.  
Using The System Setup Navigation Keys  
Keys  
Action  
Up arrow  
Down arrow  
<Enter>  
Spacebar  
<Tab>  
Moves to the previous field.  
Moves to the next field.  
Allows you to type in a value in the selected field (if applicable) or follow the link in the field.  
Expands or collapses a drop-down menu, if applicable.  
Moves to the next focus area.  
NOTE: For the standard graphics browser only.  
<Esc>  
<F1>  
Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen  
displays a message that prompts you to save any unsaved changes and restarts the system.  
Displays the System Setup help file.  
NOTE: For most of the options, any changes that you make are recorded but do not take  
effect until you restart the system.  
20  
     
System Setup Options  
System Setup Main Screen  
NOTE: Press <Alt><F> to reset the BIOS or UEFI settings to their default settings.  
Menu Item  
Description  
System BIOS  
iDRAC Settings  
Device Settings  
This option is used to view and configure BIOS settings.  
This option is used to view and configure iDRAC settings.  
This option is used to view and configure device settings.  
System BIOS Screen  
NOTE: The options for System Setup change based on the system configuration.  
NOTE: System Setup defaults are listed under their respective options in the following sections, where applicable.  
Menu Item  
Description  
System Information  
Displays information about the system such as the system model name, BIOS version, Service  
Tag, and so on.  
Memory Settings  
Displays information and options related to installed memory.  
Processor Settings  
Displays information and options related to the processor such as speed, cache size, and so  
on.  
SATA Settings  
Boot Settings  
Displays options to enable or disable the integrated SATA controller and ports.  
Displays options to specify the boot mode (BIOS or UEFI). Enables you to modify UEFI and BIOS  
boot settings.  
Integrated Devices  
Displays options to enable or disable integrated device controllers and ports, and to specify  
related features and options.  
Serial Communication Displays options to enable or disable the serial ports and specify related features and options.  
System Profile  
Settings  
Displays options to change the processor power management settings, memory frequency,  
and so on.  
System Security  
Displays options to configure the system security settings like, system password, setup  
password, TPM security, and so on. It also enables or disables the power and NMI buttons on  
the system.  
Miscellaneous  
Settings  
Displays options to change the system date, time, and so on.  
System Information Screen  
Menu Item  
Description  
System Model Name Displays the system model name.  
21  
       
Menu Item  
System BIOS Version Displays the BIOS version installed on the system.  
System Service Tag Displays the system Service Tag.  
Description  
System Manufacturer Displays the name of system manufacturer.  
System Manufacturer Displays the contact information of the system manufacturer.  
Contact Information  
Memory Settings Screen  
Menu Item  
Description  
System Memory Size Displays the amount of memory installed in the system.  
System Memory Type Displays the type of memory installed in the system.  
System Memory  
Speed  
Displays the system memory speed.  
Displays the system memory voltage.  
Displays the amount of video memory.  
System Memory  
Voltage  
Video Memory  
System Memory  
Testing  
Specifies whether system memory tests are run during system boot. Options are Enabled and  
Disabled. By default, the System Memory Testing option is set to Disabled.  
Memory Operating  
Mode  
Specifies the memory operating mode. The options available depending on the memory  
configuration of your system are Optimizer Mode, Advanced ECC Mode, Mirror Mode, Spare  
Mode, Spare with Advanced ECC Mode, and Dell Fault Resilient Mode. By default, the Memory  
Operating Mode option is set to Optimizer Mode.  
NOTE: The Memory Operating Mode can have different defaults and available options  
based on the memory configuration.  
NOTE: The Dell Fault Resilient Mode establishes an area of memory that is fault resilient.  
This mode can be used by an operating system that supports the feature to load critical  
applications or enables the operating system kernel to maximize system availability.  
Node Interleaving  
If this field is Enabled, memory interleaving is supported if a symmetric memory configuration is  
installed. If Disabled, the system supports Non-Uniform Memory architecture (NUMA)  
(asymmetric) memory configurations. By default, Node Interleaving option is set to Disabled.  
Processor Settings Screen  
Menu Item  
Description  
Logical Processor  
Allows you to enable or disable logical processors and display the number of logical  
processors. If the Logical Processor option is set to Enabled, the BIOS displays all the logical  
processors. If this option is set to Disabled, the BIOS only displays one logical processor per  
core. By default, the Logical Processor option is set to Enabled.  
QPI Speed  
Allows you to set the QuickPath Interconnect data rate settings. By default, the QPI Speed  
option is set to Maximum data rate.  
22  
   
Menu Item  
Description  
NOTE: The QPI speed option displays only when both the processors are installed.  
Alternate RTID  
(Requestor  
Transaction ID)  
Setting  
Allows you to allocate more RTIDs to the remote socket increasing cache performance  
between the sockets or work in normal mode for NUMA. By default, the Alternate RTID  
(Requestor Transaction ID) Setting is set to Disabled.  
Virtualization  
Technology  
Allows you to enable or disable the additional hardware capabilities provided for virtualization.  
By default, the Virtualization Technology option is set to Enabled.  
Adjacent Cache Line Allows you to optimize the system for applications that require high utilization of sequential  
Prefetch  
memory access. By default, the Adjacent Cache Line Prefetch option is set to Enabled. You can  
disable this option for applications that require high utilization of random memory access.  
Hardware Prefetcher Allows you to enable or disable hardware prefetcher. By default, the Hardware Prefetcher  
option is set to Enabled.  
DCU Streamer  
Prefetcher  
Allows you to enable or disable Data Cache Unit streamer prefetcher. By default, the DCU  
Streamer Prefetcher option is set to Enabled.  
DCU IP Prefetcher  
Allows you to enable or disable Data Cache Unit IP prefetcher. By default, the DCU IP  
Prefetcher option is set to Enabled.  
Execute Disable  
Allows you enable or disable execute disable memory protection technology. By default, the  
Execute Disable option is set to Enabled.  
Logical Processor  
Idling  
Allows you to enable or disable the OS capability to put logical processors in the idling state in  
order to reduce power consumption. By default, the option is set to Disabled.  
Number of Cores per Allows you to control the number of enabled cores in each processor. By default, the Number  
Processor  
of Cores per Processor option is set to All.  
Processor 64-bit  
Support  
Specifies if the processor(s) support 64-bit extensions.  
Processor Core  
Speed  
Displays the maximum core frequency of the processor.  
Processor Bus Speed Displays the bus speed of the processors.  
NOTE: The processor bus speed option displays only when both the processors are  
installed.  
Processor 1  
NOTE: The following settings are displayed for each processor installed in the system.  
Displays the family, model and stepping of the processor as defined by Intel.  
Family-Model-  
Stepping  
Brand  
Displays the brand name reported by the processor.  
Displays the total L2 cache.  
Level 2 Cache  
Level 3 Cache  
Number of Cores  
Displays the total L3 cache.  
Displays the number of cores per processor.  
23  
SATA Settings Screen  
Menu Item  
Description  
Embedded SATA  
Allows the embedded SATA to be set to Off, ATA, AHCI, or RAID modes. By default, the  
Embedded SATA option is set to AHCI.  
Port E  
Auto enables BIOS support for the device attached to SATA port E. Off disables BIOS support  
for the device. By default, Port E is set to Auto.  
Boot Settings Screen  
Menu Item  
Boot Mode  
Description  
Allows you to set the boot mode of the system.  
CAUTION: Switching the boot mode may prevent the system from booting if the operating  
system is not installed in the same boot mode.  
If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS  
allows compatibility with non-UEFI operating systems. By default, the Boot Mode option is set  
to BIOS.  
NOTE: Setting this field to UEFI disables BIOS Boot Settings menu. Setting this field to  
BIOS disables the UEFI Boot Settings menu.  
Boot Sequence Retry Allows you to enable or disable the boot sequence retry feature. If this field is enabled and the  
system fails to boot, the system reattempts the boot sequence after 30 seconds. By default, the  
Boot Sequence Retry option is set to Disabled.  
BIOS Boot Settings  
Allows you to enable or disable BIOS Boot options.  
NOTE: This option is enabled only if the boot mode is BIOS.  
UEFI Boot Settings  
Allows you to enable or disable UEFI Boot options. The Boot options include IPv4 PXE and IPv6  
PXE. By default, the UEFI PXE boot protocol is set to IPv4.  
NOTE: This option is enabled only if the boot mode is UEFI.  
One-Time Boot  
Allows you to enable or disable a one-time boot from a selected device.  
Integrated Devices Screen  
Menu Item  
Description  
Integrated RAID  
Controller  
Allows you to enable or disable the integrated RAID controller. By default, the Integrated RAID  
Controller option is set to Enabled.  
User Accessible USB Allows you enable or disable the user accessible USB ports. Selecting Only Back Ports On  
Ports  
disables the front USB ports and selecting All Ports Off disables both front and back USB ports.  
By default, the User Accessible USB Ports option is set to All Ports On.  
Internal USB Port  
Allows you to enable or disable the internal USB port. By default, the Internal USB Port option  
is set to On.  
24  
     
Menu Item  
Description  
Internal SD Card Port Enables or disables the system’s internal SD card port. By default, Internal SD Card Port option  
is set to On.  
NOTE: This option is displayed only if IDSDM is installed on the system board.  
Internal SD Card  
Redundancy  
If set to Mirror mode, data is written on both SD cards. If any one of the SD card fails, data is  
written to the active SD card. Data from this card is copied to the replacement SD card at the  
next boot. By default, Internal SD Card Redundancy option is set to Mirror.  
NOTE: This option is displayed only if IDSDM is installed on the system board.  
Integrated Network  
Card 1  
Allows you to enable or disable the integrated network card 1. By default, the Integrated  
Network Card 1 option is set to Enabled.  
OS Watchdog Timer Allows you to enable or disable the OS watchdog timer. When this field is enabled, the  
operating system initializes the timer and the OS watchdog timer helps in recovering the  
operating system. By default, the OS Watchdog Timer option is set to Disabled.  
Embedded Video  
Controller  
Allows you to enable or disable the Embedded Video Controller. By default, the embedded  
video controller is Enabled.  
SR-IOV Global Enable Allows you to enable or disable the BIOS configuration of Single Root I/O Virtualization (SR-  
IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.  
Slot Disablement  
Allows you to enable or disable available PCIe slots on your system. The Slot Disablement  
feature controls the configuration of PCIe cards installed in the specified slot.  
CAUTION: Slot disablement must be used only when the installed peripheral card is  
preventing booting into the Operating System or causing delays in system startup. If the  
slot is disabled, both the Option ROM and UEFI driver are disabled.  
Memory Mapped I/O Allows you to enable support for PCIe devices that require large amounts of memory. By  
above 4 GB default, the option is set to Enabled.  
Serial Communications Screen  
Menu Item  
Description  
Serial Communication Allows you to select serial communication devices (Serial Device 1 and Serial Device 2) in the  
BIOS. BIOS console redirection can also be enabled and the port address used can be  
specified. By default, Serial Communication option is set to On without Console Redirection.  
Serial Port Address  
Allows you to set the port address for serial devices. By default, the Serial Port Address option  
is set to Serial Device 1=COM2, Serial Device 2=COM1.  
NOTE: Only Serial Device 2 can be used for Serial Over LAN (SOL). To use console  
redirection by SOL, configure the same port address for console redirection and the serial  
device.  
External Serial  
Connector  
Allows you to associate the external serial connector to serial device 1, serial device 2, or  
remote access device. By default, the External Serial Connector option is set to Serial Device1.  
25  
 
Menu Item  
Description  
NOTE: Only Serial Device 2 can be used for SOL. To use console redirection by SOL,  
configure the same port address for console redirection and the serial device.  
Failsafe Baud Rate  
Displays the failsafe baud rate for console redirection. The BIOS attempts to determine the  
baud rate automatically. This failsafe baud rate is used only if the attempt fails and the value  
must not be changed. By default, the Failsafe Baud Rate option is set to 115200.  
Remote Terminal  
Type  
Allows you to set the remote console terminal type. By default, the Remote Terminal Type  
option is set to VT 100/VT 220.  
Redirection After  
Boot  
Allows you to enable or disable to the BIOS console redirection when the operating system is  
loaded. By default, the Redirection After Boot option is set to Enabled.  
System Profile Settings Screen  
Menu Item  
Description  
System Profile  
Allows you to set the system profile. If you set the System Profile option to a mode other than  
Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the  
options if the mode is set to Custom. By default, the System Profile option is set to Performance  
Per Watt Optimized (DAPC). DAPC is Dell Active Power Controller.  
NOTE: The following parameters are available only when the System Profile is set to  
Custom.  
CPU Power  
Management  
Allows you to set the CPU power management. By default, the CPU Power Management option  
is set to System DBPM (DAPC). DBPM is Demand-Based Power Management.  
Memory Frequency  
Turbo Boost  
C1E  
Allows you to set the memory frequency. By default, the Memory Frequency option is set to  
Maximum Performance.  
Allows you to enable or disable the processor to operate in turbo boost mode. By default, the  
Turbo Boost option is set to Enabled.  
Allows you to enable or disable the processor to switch to a minimum performance state when  
it is idle. By default, the C1E option is set to Enabled.  
C States  
Allows you to enable or disable the processor to operate in all available power states. By  
default, the C States option is set to Enabled.  
Monitor/Mwait  
Allows you to enable Monitor/Mwait instructions in the processor. By default, the Monitor/  
Mwait option is set to Enabled for all system profiles, except Custom.  
NOTE: This option can be disabled only if the C States option in Custom mode is disabled.  
NOTE: When C States is enabled in Custom mode, changing the Monitor/Mwait setting  
does not impact system power/performance.  
Memory Patrol Scrub Allows you to set the memory patrol scrub frequency. By default, the Memory Patrol Scrub  
option is set to Standard.  
Memory Refresh Rate Allows you to set the memory refresh rate. By default, the Memory Refresh Rate option is set to  
1x.  
26  
 
Menu Item  
Description  
Memory Operating  
Voltage  
Allows you to set the DIMM voltage selection. When set to Auto, the system automatically sets  
the system voltage to the optimal setting based on the DIMM capacity and the number of  
DIMMs installed. By default, the Memory Operating Voltage option is set to Auto.  
Collaborative CPU  
When set to enabled, the CPU power management is controlled by the OS DBPM and the  
Performance Control System DBPM (DAPC). By default, the option is set to Disabled  
System Security Screen  
Menu Item  
Description  
Intel AES-NI  
The Intel AES-NI option improves the speed of applications by performing encryption and  
decryption using the Advanced Encryption Standard Instruction Set and is set to Enabled by  
default.  
System Password  
Setup Password  
Password Status  
TPM Security  
Allows you to set the system password. This option is set to Enabled by default and is read-only  
if the password jumper is not installed in the system.  
Allows you to set the setup password. This option is read-only if the password jumper is not  
installed in the system.  
Allows you to lock the system password. By default, the Password Status option is set to  
Unlocked.  
Allows you to control the reporting mode of the Trusted Platform Module (TPM). By default, the  
TPM Security option is set to Off. You can only modify the TPM Status, TPM Activation , and  
Intel TXT fields if the TPM Status field is set to either On with Pre-boot Measurements or On  
without Pre-boot Measurements.  
TPM Activation  
Allows you to change the operational state of the TPM. By default, the TPM Activation option is  
set to No Change.  
TPM Status  
TPM Clear  
Displays the TPM status.  
CAUTION: Clearing the TPM results in loss of all keys in the TPM. The loss of TPM keys  
may affect booting to the operating system.  
Allows you to clear all the contents of the TPM. By default, the TPM Clear option is set to No.  
Intel TXT  
Allows you enable or disable Intel Trusted Execution Technology. To enable Intel TXT,  
Virtualization Technology must be enabled and TPM Security must be Enabled with Pre-boot  
measurements. By default, the Intel TXT option is set to Off.  
BIOS Update Control Allows you to update the BIOS using either DOS or UEFI shell-based flash utilities. For  
environments that do not require local BIOS updates, it is recommended to set this field to  
Disabled. By default, the BIOS Update Control option is set to Unlocked.  
NOTE: BIOS updates using Dell Update Package are not affected by this option.  
Power Button  
NMI Button  
Allows you to enable or disable the power button on the front of the system. By default, the  
Power Button option is set to Enabled.  
Allows you to enable or disable the NMI button on the front of the system. By default, the NMI  
Button option is set to Disabled.  
27  
 
Menu Item  
Description  
AC Power Recovery Allows you to set how the system reacts after AC power is restored to the system. By default,  
the AC Power Recovery option is set to Last.  
AC Power Recovery Allows you to set how the system supports staggering of power up after AC power is restored  
Delay  
to the system. By default, the AC Power Recovery Delay option is set to Immediate.  
User Defined Delay  
(60s to 240s)  
Allows you to set the User Defined Delay when the User Defined option for AC Power Recovery  
Delay is selected.  
Miscellaneous Settings  
Menu Item  
Description  
System Time  
System Date  
Asset Tag  
Allows you to set the time on the system.  
Allows you to set the date on the system.  
Displays the asset tag and allows you to modify it for security and tracking purposes.  
Keyboard NumLock  
Allows you to set whether the system boots with the NumLock enabled or disabled. By default  
the Keyboard NumLock is set to On.  
NOTE: This field does not apply to 84-key keyboards.  
Report Keyboard  
Errors  
Allows you to set whether keyboard-related error messages are reported during system boot.  
By default, the Report Keyboard Errors field is set to Report.  
F1/F2 Prompt on Error Allows you to enable or disable the F1/F2 prompt on error. By default, F1/F2 Prompt on Error is  
set to Enabled.  
In-System  
Characterization  
This field enables or disables In-System Characterization. By default, In-System  
Characterization is set to Enabled.  
System And Setup Password Features  
You can create a system password and a setup password to secure your system. To enable creation of the system and  
setup password, the password jumper must be set to enabled. For more information on the password jumper settings,  
see System Board Jumper Settings.  
System password  
Setup password  
This is the password that you must enter before you can boot your system.  
This is the password that you must enter to access and make changes to the BIOS or UEFI  
settings of your system.  
CAUTION: The password features provide a basic level of security for the data on your system.  
CAUTION: Anyone can access the data stored on your system if the system is running and unattended.  
NOTE: Your system is shipped with the system and setup password feature disabled.  
28  
   
Assigning A System And/Or Setup Password  
NOTE: The password jumper enables or disables the System Password and Setup Password features. For more  
information on the password jumper settings, see System Board Jumper Settings.  
You can assign a new System Password and/or Setup Password or change an existing System Password and/or Setup  
Password only when the password jumper setting is enabled and Password Status is Unlocked. If the Password Status  
is Locked, you cannot change the System Password.  
If the password jumper setting is disabled, the existing System Password and Setup Password is deleted and you need  
not provide the system password to log on to the system.  
To assign a system and/or setup password:  
1. To enter System Setup, press <F2> immediately after a power-on or reboot.  
2. In the System Setup Main Menu, select System BIOS and press <Enter>.  
The System BIOS screen is displayed.  
3. In the System BIOS screen, select System Security and press <Enter>.  
The System Security screen is displayed.  
4. In the System Security screen, verify that Password Status is Unlocked.  
5. Select System Password , enter your system password, and press <Enter> or <Tab>.  
Use the following guidelines to assign the system password:  
A password can have up to 32 characters.  
The password can contain the numbers 0 through 9.  
Only lower case letters are valid, upper case letters are not allowed.  
Only the following special characters are allowed: space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`).  
A message prompts you to re-enter the system password.  
6. Re-enter the system password that you entered earlier and click OK.  
7. Select Setup Password, enter your system password and press <Enter> or <Tab>.  
A message prompts you to re-enter the setup password.  
8. Re-enter the setup password that you entered earlier and click OK.  
9. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to save the  
changes.  
NOTE: Password protection does not take effect until the system reboots.  
Deleting Or Changing An Existing System And/Or Setup Password  
Ensure that the Password jumper is set to enabled and the Password Status is Unlocked before attempting to delete or  
change the existing System and/or Setup password. You cannot delete or change an existing System password if the  
Password Status is Locked.  
To delete or change the existing System and/or Setup password:  
1. To enter System Setup, press <F2> immediately after a power-on or reboot.  
2. In the System Setup Main Menu, select System BIOS and press <Enter>.  
The System BIOS screen is displayed.  
3. In the System BIOS Screen, select System Security and press <Enter>.  
The System Security screen is displayed.  
29  
   
4. In the System Security screen, verify that Password Status is Unlocked.  
5. Select System Password, alter or delete the existing system password and press <Enter> or <Tab>.  
6. Select Setup Password, alter or delete the existing setup password and press <Enter> or <Tab>.  
NOTE: If you change the System and/or Setup password a message prompts you to re-enter the new  
password. If you delete the System and/or Setup password, a message prompts you to confirm the deletion.  
7. Press <Esc> to return to the System BIOS screen. Press <Esc> again, and a message prompts you to save the  
changes.  
NOTE: You can disable password security while logging on to the system. To disable the password security, turn on  
or reboot your system, type your password and press <Ctrl><Enter>.  
Using Your System Password To Secure Your System  
NOTE: If you have assigned a setup password, the system accepts your setup password as an alternate system  
password.  
1. Turn on or reboot your system.  
2. Type your password and press <Enter>.  
When Password Status is Locked, type the password and press <Enter> when prompted at reboot.  
If an incorrect system password is entered, the system displays a message and prompts you to re-enter your password.  
You have three attempts to enter the correct password. After the third unsuccessful attempt, the system displays an  
error message that the system has halted and must be powered down.  
Even after you shut down and restart the system, the error message is displayed until the correct password is entered.  
NOTE: You can use the Password Status option in conjunction with the System Password and Setup Password  
options to protect your system from unauthorized changes.  
Operating With A Setup Password Enabled  
If Setup Password is Enabled, enter the correct setup password before modifying most of the System Setup options.  
If you do not enter the correct password in three attempts, the system displays the message  
Invalid Password! Number of unsuccessful password attempts: <x> System Halted!  
Must power down.  
Even after you shut down and restart the system, the error message is displayed until the correct password is entered.  
The following options are exceptions:  
If System Password is not Enabled and is not locked through the Password Status option, you can assign a system  
password.  
You cannot disable or change an existing system password.  
NOTE: You can use the Password Status option in conjunction with the Setup Password option to protect the  
system password from unauthorized changes.  
Entering The UEFI Boot Manager  
NOTE: Operating systems must be 64-bit UEFI-compatible (for example, Microsoft Windows Server 2008 x64  
version) to be installed from the UEFI boot mode. DOS and 32-bit operating systems can only be installed from the  
BIOS boot mode.  
The Boot Manager enables you to:  
30  
     
Add, delete, and arrange boot options.  
Access System Setup and BIOS-level boot options without restarting.  
To enter the Boot Manager:  
1. Turn on or restart your system.  
2. Press <F11> after you see the following message:  
<F11> = UEFI Boot Manager  
If your operating system begins to load before you press <F11>, allow the system to finish booting, and then restart  
your system and try again.  
Using The Boot Manager Navigation Keys  
Key  
Description  
Up arrow  
Down arrow  
<Enter>  
Spacebar  
<Tab>  
Moves to the previous field.  
Moves to the next field.  
Allows you to type in a value in the selected field (if applicable) or follow the link in the field.  
Expands or collapses a drop-down list, if applicable.  
Moves to the next focus area.  
NOTE: For the standard graphics browser only.  
<Esc>  
<F1>  
Moves to the previous page till you view the main screen. Pressing <Esc> in the main screen  
exits the Boot Manager and proceeds with system boot.  
Displays the System Setup help file.  
NOTE: For most of the options, any changes that you make are recorded but do not take effect until you restart the  
system.  
Boot Manager Screen  
Menu Item  
Description  
Continue Normal  
Boot  
The system attempts to boot to devices starting with the first item in the boot order. If the boot  
attempt fails, the system continues with the next item in the boot order until the boot is  
successful or no more boot options are found.  
BIOS Boot Menu  
UEFI Boot Menu  
Displays the list of available BIOS boot options (marked with asterisks). Select the boot option  
you wish to use and press <Enter>.  
Displays the list of available UEFI boot options (marked with asterisks). Select the boot option  
you wish to use and press <Enter>. The UEFI Boot Menu enables you to Add Boot Option,  
Delete Boot Option, or Boot From File.  
Driver Health Menu  
Displays a list of the drivers installed on the system and their health status.  
Launch System Setup Enables you to access the System Setup.  
System Utilities Enables you to access the BIOS Update File Explorer, run the Dell Diagnostics program, and  
reboot the system.  
31  
   
UEFI Boot Menu  
Menu Item  
Description  
Select UEFI Boot  
Option  
Displays the list of available UEFI boot options (marked with asterisks), select the boot option  
you wish to use and press <Enter>.  
Add Boot Option  
Delete Boot Option  
Boot From File  
Adds a new boot option.  
Deletes an existing boot option.  
Sets a one-time boot option not included in the boot option list.  
Embedded System Management  
The Dell Lifecycle Controller provides advanced embedded systems management throughout the server’s lifecycle. The  
Lifecycle Controller can be started during the boot sequence and can function independently of the operating system.  
NOTE: Certain platform configurations may not support the full set of features provided by the Lifecycle Controller.  
For more information about setting up the Lifecycle Controller, configuring hardware and firmware, and deploying the  
operating system, see the Lifecycle Controller documentation at dell.com/support/manuals.  
iDRAC Settings Utility  
The iDRAC Settings utility is an interface to setup and configure the iDRAC parameters using UEFI. You can enable or  
disable various iDRAC parameters using the iDRAC Settings Utility.  
NOTE: Accessing some of the features on the iDRAC Settings Utility requires the iDRAC7 Enterprise License  
upgrade.  
For more information on using iDRAC, see the iDRAC7 User's Guide under Software Systems Management Dell  
Remote Access Controllers, at dell.com/support/manuals.  
Entering The iDRAC Settings Utility  
1. Turn on or restart the managed system.  
2. Press <F2> during Power-on Self-test (POST).  
3. In the System Setup Main Menu page, click iDRAC Settings.  
The iDRAC Settings screen is displayed.  
Changing The Thermal Settings  
The iDRAC Settings utility enables you to select and customize the thermal control settings for your system.  
1.  
2.  
Enter the iDRAC Settings utility.  
Under iDRAC Settings Thermal User Option, select between the following options:  
Default  
Maximum Exhaust Temperature  
Fan Speed Offset  
32  
         
NOTE: When the User Option is set to the default Auto setting, the user option cannot be modified.  
3.  
4.  
Set the Maximum Air Exhaust Temperature or the Fan Speed Offset fields.  
Click Back Finish Yes.  
33  
34  
3
Installing System Components  
Recommended Tools  
You may need the following items to perform the procedures in this section:  
Key to the system keylock  
#1 and #2 Phillips screwdrivers  
T10 and T15 Torx screwdrivers  
Wrist grounding strap connected to ground  
Following tools are required for assembling cables for a DC power supply unit (PSU), when available:  
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire  
AMP 90871-1 hand-crimping tool or equivalent  
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding).  
Front Bezel (Optional)  
Installing The Front Bezel  
1. Hook the right end of the bezel onto the chassis.  
2. Fit the free end of the bezel onto the system.  
3. Secure the bezel with the keylock.  
Figure 11. Installing and Removing the Front Bezel  
1.  
release latch  
35  
       
2.  
3.  
4.  
keylock  
front bezel  
locking hook  
Removing The Front Bezel  
1. Unlock the keylock at the left end of the bezel.  
2. Lift the release latch next to the keylock.  
3. Rotate the left end of the bezel away from the front panel.  
4. Unhook the right end of the bezel and pull the bezel away from the system.  
Opening And Closing The System  
WARNING: Whenever you need to lift the system, get others to assist you. To avoid injury, do not attempt to lift the  
system by yourself.  
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric  
shock.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: Do not operate the system without the cover for a duration exceeding five minutes.  
Opening The System  
NOTE: It is recommended that you always use a static mat and static strap while working on components in the  
interior of the system.  
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
2. Rotate the latch release lock counter clockwise to the unlocked position.  
3. Lift the latch on top of the system and slide the cover back.  
4. Grasp the cover on both sides and carefully lift the cover away from the system.  
36  
     
Figure 12. Opening and Closing the System  
1.  
2.  
3.  
system cover  
latch  
latch release lock  
Closing The System  
1. Lift the latch on the cover.  
2. Place the cover onto the chassis and offset the cover slightly back so that it clears the chassis hooks and lays flush  
on the chassis.  
3. Push down the latch to move the cover into the closed position.  
4. Rotate the latch release lock in a clockwise direction to secure the cover.  
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Inside The System  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: Components that are hot-swappable are marked orange, and touch-points on the components are marked  
blue.  
37  
   
Figure 13. Inside the System—Redundant Power Supply Unit Chassis  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
cooling shroud  
10.  
11.  
12.  
13.  
14.  
15.  
16.  
17.  
cooling fans (6)  
optical drive (optional)  
hard drives (8)  
expansion-card latch  
power supply (redundant)  
expansion-card riser 2  
expansion card  
expansion-card latch  
expansion-card riser 1  
heat sink for processor 1  
DIMMs (12)  
information tag  
control-panel board  
hard-drive backplane  
power-distribution board  
power-interposer board  
38  
Figure 14. Inside the System—Non-Redundant Power Supply Unit Chassis  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
cooling shroud  
9.  
DIMMs (12)  
cooling fans (6)  
optical drive (optional)  
hard drives (8)  
information tag  
expansion-card latch  
power supply (non-redundant)  
expansion-card riser 2  
expansion card  
expansion-card latch  
expansion-card riser 1  
heat sink for processor 1  
10.  
11.  
12.  
13.  
14.  
15.  
control-panel board  
hard-drive backplane  
Cooling Shroud  
39  
 
Removing The Cooling Shroud  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: Never operate your system with the cooling shroud removed. The system may get overheated quickly,  
resulting in shutdown of the system and loss of data.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. If applicable, remove the full-length full-height expansion card installed on slot 2 of the expansion-card riser 2  
4. Hold the touch points and lift the cooling shroud away from the system.  
Figure 15. Removing and Installing the Cooling Shroud  
1. cooling shroud  
2. expansion-card latch  
3. tabs (3)  
5. cooling shroud alignment slots on the fan  
bracket (2)  
4. cooling shroud alignment slot on the cable  
retention bracket  
40  
 
Installing The Cooling Shroud  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: For proper seating of the cooling shroud in the system chassis, ensure that the cables inside the system are  
routed appropriately.  
1. Align the tabs on the cooling shroud with the alignment slots on the fan bracket, and the cable retention bracket.  
2. Lower the cooling shroud into the chassis until firmly seated.  
3. If applicable, install the full-length full-height expansion card on slot 2 of expansion-card riser 2.  
4. Close the system.  
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
System Memory  
Your system supports DDR3 unbuffered ECC DIMMs (UDIMM ECC) and registered DIMMs (RDIMMs). It supports DDR3  
and DDR3L voltage specifications.  
NOTE: MT/s indicates DIMM speed in MegaTransfers per second.  
Memory bus operating frequency can be 1600 MT/s, 1333 MT/s, 1066 MT/s, or 800 MT/s depending on:  
DIMM type (UDIMM or RDIMM)  
DIMM configuration (number of ranks)  
maximum frequency of the DIMMs  
number of DIMMs populated per channel  
DIMM operating voltage  
system profile selected (for example, Performance Optimized, Custom, or Dense Configuration Optimized)  
maximum supported DIMM frequency of the processors  
The following table shows the memory populations and operating frequencies for the supported configurations.  
DIMM Type DIMMs  
Operating Frequency (in MT/s)  
Maximum DIMM Rank/  
Channel  
Populated/  
Channel  
1.5 V  
1.35 V  
UDIMM ECC  
RDIMM  
1
2
1
1333, 1066, and 800  
1333, 1066, and 800  
1333, 1066 and 800  
1066 and 800  
Dual rank  
Dual rank  
1600, 1333, 1066 and 800 1333, 1066 and 800  
1333  
Dual rank  
Quad rank  
1066 and 800  
1333, 1066 and 800  
1600, 1333, 1066 and 1066 1333, 1066, and 800  
1066 and 800 1066 and 800  
1066 and 800  
Dual rank  
Quad rank  
2
The system contains 12 memory sockets split into two sets of six sockets, one set per processor. Each six-socket set is  
organized into three channels. In each channel, the release levers of the first socket is marked white and the second  
black.  
41  
   
NOTE: DIMMs in sockets A1 to A6 are assigned to processor 1 and DIMMs in sockets B1 to B6 are assigned to  
processor 2.  
Figure 16. Memory Socket Locations  
Memory channels are organized as follows:  
Processor 1  
channel 1: memory sockets A1 and A4  
channel 2: memory sockets A2 and A5  
channel 3: memory sockets A3 and A6  
channel 1: memory sockets B1 and B4  
channel 2: memory sockets B2 and B5  
channel 3: memory sockets B3 and B6  
Processor 2  
42  
General Memory Module Guidelines  
This system supports Flexible Memory Configuration, enabling the system to be configured and run in any valid chipset  
architectural configuration. The following are the recommended guidelines for best performance:  
UDIMMs and RDIMMs must not be mixed.  
x4 and x8 DRAM based DIMMs can be mixed. For more information, see Mode-Specific Guidelines.  
A maximum of two UDIMMs can be populated in a channel.  
A maximum of two quad-rank RDIMMs can be populated in a channel.  
A maximum of two single- or dual-rank RDIMMs can be populated in a channel.  
One quad-rank RDIMM and one single- or dual-rank RDIMM can be populated per channel.  
Populate DIMM sockets only if a processor is installed. For single-processor systems, sockets A1 to A6 are  
available. For dual-processor systems, sockets A1 to A6 and sockets B1 to B6 are available.  
If a processor is installed, install DIMM blanks in the vacant memory sockets assigned to the processor to ensure  
proper system cooling.  
Populate all sockets with white release tabs first and then black.  
Populate the sockets by highest rank count in the following order - first in sockets with white release levers and then  
black. For example, if you want to mix quad-rank and dual-rank DIMMs, populate quad-rank DIMMs in the sockets  
with white release tabs and dual-rank DIMMs in the sockets with black release tabs.  
In a dual-processor configuration, the memory configuration for each processor must be identical. For example, if  
you populate socket A1 for processor 1, then populate socket B1 for processor 2, and so on.  
Memory modules of different sizes can be mixed provided that other memory population rules are followed (for  
example, 2 GB and 4 GB memory modules can be mixed).  
Depending on mode-specific guidelines, populate two or three DIMMs per processor (one DIMM per channel) at a  
time to maximize performance. For more information, see Mode-Specific Guidelines.  
If memory modules with different speeds are installed, they will operate at the speed of the slowest installed  
memory module(s) or slower depending on system DIMM configuration.  
Mode-Specific Guidelines  
Three memory channels are allocated to each processor. The allowable configurations depend on the memory mode  
selected.  
NOTE: x4 and x8 DRAM based DIMMs can be mixed providing support for (Reliability, Availability, and  
Serviceability) RAS features. However, all guidelines for specific RAS features must be followed. x4 DRAM based  
DIMMs retain Single Device Data Correction (SDDC) in either memory optimized (independent channel) or  
Advanced ECC modes. x8 DRAM based DIMMs require Advanced ECC mode to gain SDDC.  
The following sections provide additional slot population guidelines for each mode.  
Advanced ECC (Lockstep)  
Advanced ECC mode extends SDDC from x4 DRAM based DIMMs to both x4 and x8 DRAMs. This protects against single  
DRAM chip failures during normal operation.  
Memory installation guidelines:  
Memory sockets A1, A4, B1, and B4 are disabled and do not supported Advanced ECC mode.  
DIMMs must be installed in matched pairs — DIMMs installed in memory sockets (A2, B2) must match DIMMs  
installed in memory sockets (A3, B3) and DIMMs installed in memory sockets (A5, B5) must match DIMMs installed  
in memory sockets (A6, B6).  
43  
     
NOTE: Advanced ECC with mirroring is not supported.  
Memory Optimized (Independent Channel) Mode  
This mode supports SDDC only for memory modules that use x4 device width and does not impose any specific slot  
population requirements.  
Memory Sparing  
NOTE: To use memory sparing, this feature must be enabled in the System Setup.  
In this mode, one rank per channel is reserved as a spare. If persistent correctable errors are detected on a rank, the  
data from this rank is copied to the spare rank and the failed rank is disabled.  
With memory sparing enabled, the system memory available to the operating system is reduced by one rank per  
channel. For example, in a system with three 8 GB dual-rank DIMMs, the available system memory is: 1/2 (ranks/  
channel) × 3 (DIMMs) × 8 GB = 12 GB, and not 3 (DIMMs) × 8 GB = 24 GB.  
NOTE: Memory sparing does not offer protection against a multi-bit uncorrectable error.  
NOTE: Both Advanced ECC/Lockstep and Optimizer modes support Memory Sparing.  
Memory Mirroring  
Memory Mirroring offers the strongest DIMM reliability mode compared to all other modes, providing improved  
uncorrectable multi-bit failure protection. In a mirrored configuration, the total available system memory is one half of  
the total installed physical memory. Half of the installed memory is used to mirror the active DIMMs. In the event of an  
uncorrectable error, the system will switch over to the mirrored copy. This ensures SDDC and multi-bit protection.  
Memory installation guidelines:  
NOTE: The first memory channel for each processor (Channel 1) is disabled and not available for Memory  
Mirroring.  
Memory channels 2 and 3 must be populated.  
Memory modules must be identical in size, speed, and technology.  
DIMMs installed in memory sockets with white release tabs must be identical and similar rule applies for sockets  
with black release tabs. For example, DIMMs installed in sockets A2 and A3 must be identical.  
Sample Memory Configurations  
The following tables show sample memory configurations that follow the appropriate memory guidelines stated in this  
section.  
NOTE: 16 GB quad-rank RDIMMs are not supported.  
NOTE: 1R, 2R, and 4R in the following tables indicate single-, dual-, and quad-rank DIMMs respectively.  
Table 1. Memory Configurations — Single Processor  
System Capacity  
(in GB)  
DIMM Size (in  
GB)  
Number of  
DIMMs  
Organization and  
Speed  
DIMM Slot Population  
A1  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
2
2
1
1R x8, 1333 MT/s  
4
2
2
A1, A2  
44  
       
System Capacity  
(in GB)  
DIMM Size (in  
GB)  
Number of  
DIMMs  
Organization and  
Speed  
DIMM Slot Population  
1R x8, 1600 MT/s  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
10  
12  
20  
24  
32  
48  
96  
2
5
3
5
3
4
3
6
A1, A2, A3, A4, A5  
A1, A2, A3  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
4
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
4
A1, A2, A3, A4, A5  
A1, A2, A3  
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
8
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
8
A1, A2, A3, A4  
A1, A2, A3  
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
16  
16  
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
A1, A2, A3, A4, A5, A6  
4R x4, 1066 MT/s  
4R x4, 1066 MT/s  
128  
192  
32  
32  
4
6
A1, A2, A3, A4  
A1, A2, A3, A4, A5, A6  
Table 2. Memory Configurations — Two Processors  
System Capacity (in  
GB)  
DIMM Size (in  
GB)  
Number of  
DIMMs  
Organization and  
Speed  
DIMM Slot Population  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
4
2
2
A1, B1  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
8
2
4
A1, A2, B1, B2  
1R x8, 1333 MT/s  
1R x8, 1600 MT/s  
12  
24  
48  
96  
128  
160  
192  
2
6
A1, A2, A3, B1, B2, B3  
A1, A2, A3, B1, B2, B3  
A1, A2, A3, B1, B2, B3  
A1, A2, A3, B1, B2, B3  
A1, A2, A3, A4, B1, B2, B3, B4  
2R x8, 1333 MT/s  
2R x8, 1600 MT/s  
4
6
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
8
6
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
16  
16  
16  
16  
6
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
8
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
10  
12  
A1, A2, A3, A4, A5, B1, B2, B3,  
B4, B5  
2R x4, 1333 MT/s  
2R x4, 1600 MT/s  
A1, A2, A3, A4, A5, A6, B1, B2,  
B3, B4, B5, B6  
45  
System Capacity (in  
GB)  
DIMM Size (in  
GB)  
Number of  
DIMMs  
Organization and  
Speed  
DIMM Slot Population  
4R x4, 1066 MT/s  
4R x4, 1066 MT/s  
256  
384  
32  
32  
8
A1, A2, A3, A4, B1, B2, B3, B4  
12  
A1, A2, A3, A4, A5, A6, B1, B2,  
B3, B4, B5, B6  
Removing Memory Modules  
WARNING: The memory modules are hot to the touch for some time after the system has been powered down.  
Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges  
and avoid touching the components or metallic contacts on the memory module.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is  
not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Remove the cooling shroud.  
4. Locate the appropriate memory-module socket(s).  
5. To release the memory-module blank from the socket, simultaneously press the ejectors on both ends of the  
memory module socket.  
CAUTION: Handle each memory module only on the card edges, making sure not to touch the middle of the  
memory module or metallic contacts. To avoid damaging the memory module, handle only one memory  
module at a time.  
Figure 17. Ejecting The Memory Module  
1.  
2.  
3.  
memory module  
memory-module socket ejectors (2)  
memory-module socket  
6. If a memory module or a memory-module blank is installed in the socket, remove it.  
NOTE: Retain removed memory-module blank(s) for future use.  
46  
 
Figure 18. Removing The Memory Module  
1. memory module/memory-module blank  
7. Install the cooling shroud.  
8. Close the system.  
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Installing Memory Modules  
WARNING: The memory modules are hot to the touch for some time after the system has been powered down.  
Allow time for the memory modules to cool before handling them. Handle the memory modules by the card edges  
and avoid touching the components or metallic contacts on the memory module.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: To ensure proper system cooling, memory-module blanks must be installed in any memory socket that is  
not occupied. Remove memory-module blanks only if you intend to install memory modules in those sockets.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
3. If applicable, remove the cooling shroud.  
4. Locate the memory-module sockets.  
CAUTION: Handle each memory module only by the card edges, making sure not to touch the middle of the  
memory module or metallic contacts. To avoid damaging the memory module, handle only one memory  
module at a time.  
5. If a memory module or a memory-module blank is installed in the socket, remove it.  
NOTE: Retain removed memory-module blank(s) for future use.  
6. Align the memory-module's edge connector with the alignment key of the memory-module socket, and insert the  
memory module in the socket.  
NOTE: The memory-module socket has an alignment key that allows you to install the memory module in the  
socket in only one orientation.  
47  
 
CAUTION: To prevent damage to the memory-module socket during installation, apply pressure at both ends  
of the memory module evenly. Do not apply pressure to the center of the memory module.  
7. Press down on the memory module with your thumbs until the memory module snaps into place.  
Figure 19. Installing The Memory Module  
1.  
2.  
3.  
4.  
memory module  
memory-module ejectors  
memory-module socket alignment key  
memory-module alignment key  
NOTE: When the memory module is properly seated in the socket, the levers on the memory-module socket  
align with the levers on the other identical sockets that have memory modules installed.  
8. Repeat step 4 through step 7 of this procedure to install the remaining memory modules.  
9. Replace the cooling shroud.  
10. Close the system.  
11. Reconnect the system to its electrical outlet and turn on the system, including any attached peripherals.  
12. Press <F2> to enter the System Setup, and check the memory settings.  
The system should have already changed the value to reflect the newly installed memory.  
13. If the value is incorrect, one or more of the memory modules may not be installed properly. Repeat step 4 through  
step 7 of this procedure, checking to ensure that the memory modules are firmly seated in their sockets.  
14. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
Hard Drives  
Your system supports:  
up to eight 3.5 inch or 2.5 inch hot-swappable hard drives  
up to four 3.5 inch or 2.5 inch hot-swappable hard drives for software RAID  
NOTE: On software RAID systems, slots 4 through 7 are not functional and are pre-installed with dual slot hard-  
drive blanks.  
All hard drives connect to the system board through the hard-drive backplane. Hot-swappable hard drives are supplied  
in hot-swappable hard-drive carriers that fit in the hard-drive slots.  
48  
 
CAUTION: Before attempting to remove or install a hard drive while the system is running, see the documentation  
for the storage controller card to ensure that the host adapter is configured correctly to support hot-swap hard  
drive removal and insertion.  
CAUTION: Do not turn off or reboot your system while the hard drive is being formatted. Doing so can cause a hard  
drive failure.  
NOTE: Use only hard drives that have been tested and approved for use with the hard-drive backplane.  
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard  
drives can take a number of hours to format.  
Removing A 3.5 Inch Hard-Drive Blank  
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have drive blanks installed.  
1. If installed, remove the front bezel.  
2. Grasp the front of the hard-drive blank, press the release button and slide the blank out until it is free of the hard-  
drive slot.  
Figure 20. Removing and Installing a 3.5 Inch Hard-Drive Blank  
1.  
2.  
hard-drive blank  
release button  
Installing A 3.5 Inch Hard-Drive Blank  
CAUTION: To avoid damaging the hard-drive blank's metal spring, follow the hard-drive blank installation sequence  
described in the figure below.  
1. If installed, remove the front bezel.  
2. Insert the hard-drive blank into the hard-drive slot until the release button clicks into place.  
3. If applicable, install the front bezel.  
49  
   
Figure 21. Hard-Drive Blank Installation Sequence  
Removing A Dual Slot Hard-Drive Blank  
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks installed.  
NOTE: Systems configured for software RAID support only four hard drives. The remaining hard-drive slots are pre-  
installed with dual slot hard-drive blanks, and are not available for software RAID.  
NOTE: This is a service only procedure.  
1. If installed, remove the front bezel.  
2. Using a screwdriver, push the release tabs to unlock the dual slot hard-drive blank from the chassis.  
3. Pull the hard-drive blank at the corners until it is free of the hard-drive slot.  
50  
 
Figure 22. Removing and Installing A Dual Slot Hard-Drive Blank  
1.  
2.  
dual slot hard-drive blank  
release tabs (2)  
Installing A Dual Slot Hard-Drive Blank  
1. If installed, remove the front bezel.  
2. Insert the dual slot hard-drive blank into the hard-drive slot, and push it until the release tabs click into place.  
3. If applicable, install the front bezel.  
Removing A Hot-Swap Hard Drive  
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the  
documentation supplied with your operating system.  
1. From the management software, prepare the hard drive for removal. Wait until the indicators on the hard-drive  
carrier signal that the hard drive can be removed safely. For more information, see the documentation for the  
storage controller.  
If the hard drive is online, the green activity/fault indicator flashes as the drive is turned off. When the hard-drive  
indicators are off, the hard drive is ready for removal.  
2. Press the release button to open the hard-drive carrier release handle.  
3. Slide the hard-drive carrier out until it is free of the hard-drive slot.  
CAUTION: To maintain proper system cooling, all empty hard-drive slots must have hard-drive blanks  
installed.  
4. Insert a hard-drive blank in the empty hard-drive slot.  
51  
   
Figure 23. Removing and Installing a Hot-Swap Hard Drive  
1.  
2.  
3.  
release button  
hard drive  
hard-drive carrier handle  
Installing A Hot-Swap Hard Drive  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: Use only hard drives that have been tested and approved for use with the hard-drive backplane.  
CAUTION: Combining SAS and SATA hard drives in the same RAID volume is not supported.  
CAUTION: When installing a hard drive, ensure that the adjacent drives are fully installed. Inserting a hard-drive  
carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed  
carrier's shield spring and make it unusable.  
CAUTION: To prevent data loss, ensure that your operating system supports hot-swap drive installation. See the  
documentation supplied with your operating system.  
CAUTION: When a replacement hot-swappable hard drive is installed and the system is powered on, the hard drive  
automatically begins to rebuild. Make absolutely sure that the replacement hard drive is blank or contains data that  
you wish to have over-written. Any data on the replacement hard drive is immediately lost after the hard drive is  
installed.  
1. If a hard-drive blank is installed in the hard-drive slot, remove it.  
2. Install a hard drive in the hard-drive carrier.  
3. Press the release button on the front of the hard-drive carrier and open the hard-drive carrier handle.  
4. Insert the hard-drive carrier into the hard-drive slot until the carrier connects with the backplane.  
5. Close the hard-drive carrier handle to lock the hard drive in place.  
52  
 
Removing A 2.5 Inch Hard Drive From A 3.5 Inch Hard-Drive Adapter  
NOTE: A 2.5 inch hard drive is installed into a 3.5 inch hard-drive adapter, which is then installed in the 3.5 inch  
hard-drive carrier  
1. Remove the two screws from the side of the 3.5 inch hard-drive adapter.  
2. Remove the hard-drive away from the hard-drive adapter.  
Figure 24. Removing and Installing a 2.5 Inch Hard Drive Into a 3.5 Inch Hard-Drive Adapter  
1.  
2.  
3.  
screws (2)  
3.5 inch hard-drive adapter  
2.5 inch hard drive  
Installing A 2.5 Inch Hard Drive Into A 3.5 Inch Hard-Drive Adapter  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Align the screw holes on the 2.5 inch hard drive with the screw holes on the 3.5 inch hard-drive adapter.  
2. Install the screws to secure the hard drive to the hard-drive adapter.  
Removing A Hard Drive Or A Hard-Drive Adapter From A Hard-Drive Carrier  
1. Remove the screws from the slide rails on the hard-drive carrier.  
2. Lift the hard-drive adapter out of the hard-drive carrier.  
53  
     
Figure 25. Removing and Installing a Hot-Swap Hard Drive Into a Hard-Drive Carrier  
1.  
2.  
3.  
4.  
hard-drive carrier  
screws (4)  
hard drive  
screw holes (4)  
54  
Figure 26. Removing and Installing a Hard-Drive Adapter Into a 3.5 Inch Hard-Drive Carrier  
1.  
2.  
3.  
4.  
hard-drive carrier  
screws (5)  
hard-drive adapter  
2.5 inch hard drive  
Installing A Hard Drive Or A Hard-Drive Adapter Into A Hard-Drive Carrier  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Insert the hard-drive adapter into the hard-drive carrier with the connector end of the hard drive toward the back.  
2. Align the screw holes on the hard drive with the back set of holes on the hard-drive carrier.  
When aligned correctly, the back of the hard drive is flush with the back of the hard-drive carrier.  
3. Attach the screws to secure the hard drive to the hard-drive carrier.  
55  
 
Optical Drive (Optional)  
Removing The Optical Drive  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If installed, remove the front bezel.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
3. Open the system.  
4. Disconnect the power/data cable from the back of the optical drive.  
Note the routing of the power/data cable on the side on the system as you remove them from the system board and  
drive. You must route these cables properly when you replace them to prevent them from being pinched or  
crimped.  
5. To remove the optical drive, press down and push the blue release tab toward the front of the system.  
6. Slide the optical drive out of the system until it is free of the drive bay.  
7. If you are not adding a new optical drive, install the optical drive blank.  
8. Close the system.  
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
10. If applicable, install the front bezel.  
Figure 27. Removing and Installing the Optical Drive  
1.  
2.  
3.  
optical drive  
power and data cable  
release tab  
56  
   
Installing The Optical Drive  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If installed, remove the front bezel.  
2. Turn off the system, including any attached peripherals, and disconnect the system from its electrical outlet.  
3. Open the system.  
4. Align the optical drive with its opening in the front panel.  
5. Slide in the optical drive until the latch snaps into place.  
6. Connect the power/data cable to the optical drive and system board.  
NOTE: You must route the cable properly on the side of the system to prevent it from being pinched or  
crimped.  
7. Close the system.  
8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
9. If applicable, install the front bezel.  
Cooling Fans  
Your system supports up to six cooling fans. For a system with only one processor, a dummy fan is pre-installed on the  
sixth cooling fan slot (FAN6). You must remove the dummy fan and install a cooling fan in the FAN6 slot when you install  
a second processor.  
NOTE: In the event of a problem with a particular fan, the fan number is referenced by the system’s management  
software, allowing you to easily identify and replace the proper fan by noting the fan numbers.  
Removing A Cooling Fan  
WARNING: Opening or removing the system cover when the system is on may expose you to a risk of electric  
shock. Exercise utmost care while removing or installing cooling fans.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: The procedure for removing each individual fan module is the same.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Remove the fan cable connector from the system board by pressing the tab on the cable end connector, and lifting  
it away from the system board.  
4. Free the cable from the cable holders on the fan bracket.  
5. Press the release tab on the cooling fan and lift the fan away from the chassis.  
57  
     
Figure 28. Removing and Installing a Cooling Fan  
1.  
2.  
3.  
4.  
cooling fans (6)  
cooling fan release tab  
cooling fan cable connector  
cooling fan connector on the system board  
Installing A Cooling Fan  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: If you install a second processor, you must:  
remove the dummy fan from the FAN6 slot  
install a cooling fan in the FAN6 slot  
upgrade both the expansion-card risers (riser 1 and riser 2)  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
58  
 
3. Remove the cooling shroud.  
4. Align the fan with the cable end of the fan toward the system board.  
5. Lower the fan into the fan bracket until it clicks into position.  
6. Connect the fan's power cable to the power connector on the system board.  
7. Route the cable through the cable holders on the fan bracket.  
8. Replace the cooling shroud.  
9. Close the system.  
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Internal USB Memory Key (Optional)  
An optional USB memory key installed inside your system can be used as a boot device, security key, or mass storage  
device. The USB connector must be enabled by the Internal USB Port option in the Integrated Devices screen of the  
System Setup.  
To boot from the USB memory key, configure the USB memory key with a boot image, and then specify the USB memory  
key in the boot sequence in the System Setup.  
NOTE: The internal USB connector is located on the expansion-card riser 2.  
Replacing the Internal USB Key  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Locate the USB connector / USB key on the expansion-card riser 2.  
4. If installed, remove the USB key.  
5. Insert the USB key into the USB connector.  
6. Close the system.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
8. Enter the System Setup and verify that the USB key is detected by the system.  
59  
   
Figure 29. Replacing the Internal USB Key  
1.  
2.  
USB memory key connector  
USB memory key  
Expansion Cards And Expansion-Card Risers  
NOTE: A missing or an unsupported expansion-card riser logs an SEL event. It does not prevent your system from  
powering on and no BIOS POST message or F1/F2 pause is displayed.  
Expansion-Card Installation Guidelines  
Your system supports:  
PCI Express Generation 2 and Generation 3 expansion cards.  
Different expansion-card risers for single- and dual-processor configurations. The following table provides the riser  
configurations for single- and dual-processor systems:  
Table 3. Riser Configuration for Single- and Dual-Processor Systems  
Expansion Card Slots  
Number of Processors  
Riser 1  
Riser 2  
PCIE_G3_X8  
PCIE_G3_X4  
PCIE_G3_X4  
PCIE_G2_X4  
iDRAC Ports Card  
One  
Two  
PCIE_G3_X8  
PCIE_G3_X8  
PCIE_G3_X8  
PCIE_G3_X16  
iDRAC Ports Card  
NOTE: The expansion-card risers listed in the above table cannot be interchanged between single- and dual-  
processor systems.  
Only a three-fourth length GPU card is supported for the PCIe expansion card slot (slot 2) on riser 2.  
Use the following table as a guide for installing expansion cards to ensure proper cooling and mechanical fit. The  
expansion cards with the highest priority must be installed first using the slot priority indicated. All other expansion  
cards must be installed in card priority and slot priority order.  
60  
   
Table 4. Expansion-Card Installation Priority for Riser 2  
Card Priority  
Card Type  
External RAID  
CNAs  
Slot Priority  
4, 3, 2  
Max Allowed  
1
2
3
4
5
6
7
8
1
3
3
3
3
3
3
3
4, 3, 2  
10 Gb NICs  
FC8 HBA  
4, 3, 2  
4, 3, 2  
FC4 HBA  
4, 3, 2  
1 Gb NICs  
Non-RAID  
FC16 HBA  
4, 3, 2  
4, 3, 2  
4, 3, 2  
Removing An Expansion Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Lift the expansion-card latch.  
4. Hold the expansion card by its edges and remove it from the expansion-card connector on the expansion-card  
riser.  
5. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and  
close the expansion-card latch.  
NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications  
Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in  
proper cooling and airflow inside the system.  
6. Close the system.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
61  
 
Figure 30. Removing and Installing the Expansion Card from Expansion-Card Riser 1  
1.  
2.  
3.  
expansion card  
expansion-card latch  
riser 1  
62  
Figure 31. Removing and Installing the Expansion Card from Expansion-Card Riser 2  
1.  
2.  
3.  
riser 2  
expansion-card latch  
expansion card  
Installing An Expansion Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Unpack the expansion card and prepare it for installation.  
For instructions, see the documentation accompanying the card.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
3. Open the system.  
4. Locate the expansion-card connector on the riser.  
5. Open the expansion-card latch and remove the filler bracket.  
6. If you are installing a full-length, full-height expansion card on slot 2 of the expansion-card riser 2, open the  
expansion-card holder on the cooling shroud.  
7. Holding the card by its edges, position the card so that the card-edge connector aligns with the expansion-card  
connector.  
63  
 
8. Insert the card-edge connector firmly into the expansion-card connector until the card is fully seated.  
9. Slide the expansion-card latch into position.  
10. If applicable, connect cables to the expansion card.  
11. Close the system.  
12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
13. Install any device drivers required for the card as described in the documentation for the card.  
Removing Expansion-Card Risers  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
NOTE: Before removing the expansion-card riser, ensure that there are no expansion cards installed on it.  
3. Press the release tabs and lift the expansion-card riser from the riser connector on the system board.  
Figure 32. Removing and Installing the Expansion-Card Riser 1  
1.  
2.  
3.  
4.  
expansion-card riser 1  
release tabs (2)  
riser guide pins (2)  
connector  
64  
 
Figure 33. Removing and Installing the Expansion-Card Riser 2  
1.  
2.  
3.  
expansion-card riser 2  
connector  
riser guide pins (2)  
Installing Expansion-Card Risers  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If applicable, reinstall the expansion card(s) into the expansion card riser.  
2. Align the expansion-card riser with the connector and the riser guide pin on the system board.  
3. Lower the expansion-card riser into place until the expansion-card riser connector is fully seated in the connector.  
4. Close the system.  
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
6. Install any device drivers required for the card as described in the documentation for the card.  
iDRAC Ports Card (Optional)  
The iDRAC Ports card supports:  
one 1GbE Ethernet port  
SD vFlash card  
65  
   
Removing The iDRAC Ports Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Disconnect any cables connected to the iDRAC Ports card.  
4. Lift the expansion-card latch  
5. Remove the iDRAC Ports card.  
6. If installed, remove the expansion card from slot 1 of expansion-card riser 1.  
7. Supporting the expansion-card riser, hold the iDRAC Ports card by its edges and remove it from the iDRAC Ports  
card connector on the riser.  
8. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and  
close the expansion-card latch.  
NOTE: You must install a filler bracket over an empty expansion slot to maintain Federal Communications  
Commission (FCC) certification of the system. The brackets also keep dust and dirt out of the system and aid in  
proper cooling and airflow inside the system.  
9. Close the system.  
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
66  
 
Figure 34. Removing and Installing the iDRAC Ports Card  
1.  
2.  
3.  
expansion-card riser 1  
iDRAC Ports card  
iDRAC Ports card alignment slot  
Installing The iDRAC Ports Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Unpack the iDRAC Ports card and prepare it for installation.  
For instructions, see the documentation accompanying the card.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
3. Open the system.  
4. Locate the iDRAC Ports card connector on expansion-card riser 1.  
5. Open the expansion-card latch and remove the filler bracket.  
67  
 
6. Holding the card by its edges, position the card so that the card-edge connector aligns with the iDRAC Ports card  
connector.  
7. Align the iDRAC Ports card bracket with the hooks on the chassis.  
8. Insert the card-edge connector firmly into the iDRAC Ports card connector until the card is fully seated.  
9. Slide the expansion-card latch into position.  
10. If applicable, connect cables to the iDRAC Ports card.  
11. Close the system.  
12. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
13. Install any device drivers required for the card as described in the documentation for the card.  
SD vFlash Card  
A vFlash SD card is a Secure Digital (SD) card that plugs into the vFlash SD card slot in the system. It provides persistent  
on-demand local storage and a custom deployment environment that allows automation of server configuration, scripts,  
and imaging. It emulates USB device(s). For more information, see the iDRAC7 User's Guide at dell.com/support/  
manuals.  
Replacing An SD vFlash Card  
1. Locate the vFlash media slot on the iDRAC Ports card.  
2. To remove the installed SD vFlash card, push inward on the card to release it.  
3. Pull the card from the card slot.  
Figure 35. Removing and Installing the SD vFlash Card  
1.  
2.  
SD vFlash card  
SD vFlash card slot  
4. To install the SD vFlash card, with the label side facing up, insert the contact-pin end of the SD card into the card  
slot on the module.  
NOTE: The slot is keyed to ensure correct insertion of the card.  
5. Press inward on the card to lock it into the slot.  
Internal Dual SD Module  
NOTE: When the Redundancy option is set to Mirror Mode in the Integrated Devices screen of the System Setup,  
the information is replicated from one SD card to another.  
68  
     
Removing The Internal Dual SD Module  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Locate the internal dual SD module installed on the IDSDM connector on the system board.  
4. If applicable, remove the SD card(s).  
5. Holding the tab, pull the dual SD module to remove it from the system board.  
6. Close the system.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Figure 36. Removing and Installing the Internal Dual SD Module  
1. blue pull tab  
2. SD card 1  
3. SD card 2  
4. dual SD module  
5. connector on the system board  
69  
 
Installing The Internal Dual SD Module  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Locate the connector on the system board.  
4. Align the connectors on the system board and the dual SD module.  
5. Holding the tab, push the dual SD module until it is firmly seated on the system board.  
NOTE: An L-shaped flange extended from the power supply unit cage supports the dual SD module.  
6. Close the system.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Internal SD Card  
Removing An Internal SD Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Locate the SD card slot on the internal dual SD module or the backplane expander board and press inward on the  
card to release it from the slot and remove the card.  
4. Close the system.  
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Installing An Internal SD Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: To use an SD card with your system, ensure that the internal SD card port is enabled in the System Setup.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
3. Locate the SD card connector on the internal dual SD module or the backplane expander board. With the label side  
facing up, insert the contact-pin end of the card into the slot.  
70  
       
NOTE: The slot is keyed to ensure correct insertion of the card.  
4. Press the card into the card slot to lock it into place.  
5. Close the system.  
6. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Integrated Storage Controller Card  
Your system supports an integrated storage controller card that provides the integrated storage subsystem for your  
system’s internal hard drives. The controller supports SAS and SATA hard drives and also enables you to set up the hard  
drives in RAID configurations as supported by the version of the storage controller included with your system.  
Removing The Integrated Storage Controller  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
NOTE: For easy access to the integrated storage controller, remove the expansion-card riser 2 before  
removing the integrated storage controller. See Removing Expansion-Card Risers.  
3. Push down the two release levers at the edge of the card to disengage the card from the connector.  
As the card releases from the standoffs, the connector under the card disengages from the system board  
connector.  
4. Disengage the card from the storage-controller card holder on the system board.  
5. Remove the storage-controller card from the system.  
6. Close the system.  
71  
   
Figure 37. Removing and Installing the Integrated Storage Controller  
1. storage connector on the system board  
2. touch-points (2)  
4. storage-controller card holder  
5. release levers (2)  
3. storage-controller card  
Installing The Integrated Storage Controller  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
3. Align one end of the card with the card holder on the system board.  
4. Lower the other end of the card and align the holes on the card with the locating posts of the extractors on the  
system board.  
5. Press the card down at the corners until it is fully seated.  
When the card is fully seated, the plastic standoff tab snaps over the edge of the holder.  
72  
 
6. Close the system.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Processors  
Use the following procedure when:  
Installing an additional processor  
Replacing a processor  
Removing A Processor  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Before upgrading your system, download the latest system BIOS version from dell.com/support and follow the  
instructions included in the compressed download file to install the update on your system.  
NOTE: You can update the system BIOS using the Lifecycle Controller.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. When  
disconnected from the power source, press and hold the power button for three seconds to fully drain the system  
of stored power prior to removing the cover.  
3. Open the system.  
4. Remove the cooling shroud.  
WARNING: The heat sink and processor are hot to the touch for some time after the system has been  
powered down. Allow the heat sink and processor to cool before handling them.  
CAUTION: Never remove the heat sink from a processor unless you intend to remove the processor. The heat  
sink is necessary to maintain proper thermal conditions.  
5. Using a #2 Phillips screwdriver, loosen one of the heat-sink retention sockets. Wait 30 seconds for the heat sink to  
loosen from the processor.  
6. Loosen the other three heat-sink retention sockets.  
7. Lift the heat sink away from the processor.  
73  
   
Figure 38. Removing and Installing the Heat Sink  
1.  
2.  
3.  
retention sockets (4)  
heat sink  
retention screws (4)  
CAUTION: The processor is held in its socket under strong pressure. Be aware that the release lever can  
spring up suddenly if not firmly grasped.  
8. Position your thumb firmly over the processor socket-release lever and release the lever from the locked position.  
9. Rotate the lever 90 degrees upward until the processor is released from the socket.  
10. Rotate the processor shield upward and out of the way.  
CAUTION: The socket pins are fragile and can be permanently damaged. Be careful not to bend the pins in the  
socket when removing the processor out of the socket.  
11. Lift the processor out of the socket and leave the release lever up so that the socket is ready for the new  
processor.  
74  
Figure 39. Removing and Installing a Processor  
1. processor  
5. ZIF socket  
2. processor shield  
3. notches in processor (4)  
4. socket keys (4)  
6. socket-release lever  
NOTE: After removing the processor, place it in an antistatic container for reuse, return, or temporary storage.  
Do not touch the bottom of the processor. Touch only the side edges of the processor.  
Installing A Processor  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: If you install a second processor, you must:  
remove the dummy fan from the FAN6 slot  
install a cooling fan in the FAN6 slot  
upgrade both the expansion-card risers (riser 1 and riser 2)  
1. Before upgrading your system, download the latest system BIOS version from dell.com/support and follow the  
instructions included in the compressed download file to install the update on your system.  
75  
 
NOTE: You can update the system BIOS using the Lifecycle Controller.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. When  
disconnected from power, press and hold the power button for three seconds to fully drain the system of stored  
power prior to removing the cover.  
3. Open the system.  
4. Remove the cooling shroud.  
WARNING: The heat sink and processor are hot to the touch for some time after the system has been  
powered down. Allow the heat sink and processor to cool before handling them.  
CAUTION: Never remove the heat sink from a processor unless you intend to remove the processor. The heat  
sink is necessary to maintain proper thermal conditions.  
5. Position your thumb firmly over the processor socket-release lever and release the lever from the locked position.  
6. Rotate the lever 90 degrees upward.  
7. Rotate the processor shield upward and out of the way.  
8. Unpack the new processor.  
9. With the release lever on the processor socket in the open position, align the processor with the socket keys on the  
ZIF socket.  
CAUTION: Positioning the processor incorrectly can permanently damage the system board or the processor.  
Be careful not to bend the pins in the socket.  
CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages  
easily into the socket.  
10. Set the processor lightly in the socket.  
11. Close the processor shield.  
12. Rotate the socket release lever down until it locks into position.  
13. Using a clean lint-free cloth, remove the thermal grease from the heat sink.  
CAUTION: Applying too much thermal grease can result in excess grease coming in contact with and  
contaminating the processor socket.  
14. Open the grease applicator included with your processor kit and apply all of the thermal grease in the applicator to  
the center of the topside of the new processor.  
15. Place the heat sink on the processor.  
16. Using a #2 Phillips screwdriver, tighten the heat-sink retention sockets.  
17. Install the cooling shroud.  
18. Close the system.  
19. Reconnect your system and peripherals to their electrical outlets, and turn on the system.  
20. Press <F2> to enter the System Setup and check that the processor information matches the new system  
configuration.  
21. Run the system diagnostics to verify that the new processor operates correctly.  
Power Supplies  
Your system supports:  
Two 495 W, 750 W, or 1100 W AC power supply modules  
One cabled power supply module 550 W (non-redundant)  
Two 750 W or 1100 W DC power supply modules  
76  
 
When two identical power supplies are installed, the power supply configuration is redundant (1 + 1). In  
redundant mode, power is supplied to the system equally from both power supplies to maximize efficiency.  
When only one power supply is installed, the power supply configuration is non-redundant (1 + 0). Power is  
supplied to the system only by the single power supply.  
NOTE: If two power supplies are used, they must be of the same type and have the same maximum output power.  
NOTE: Titanium power supply is nominally rated for 200 VAC to 240 VAC input only.  
CAUTION: Do not operate your system with only one 1100 W AC or DC power supply installed.  
Removing An AC Power Supply  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: The system requires one power supply for normal operation. On power-redundant systems, remove and  
replace only one power supply at a time in a system that is powered on.  
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with power supply  
removal. For information about the cable management arm, see the system’s rack documentation.  
1. Disconnect the power cable from the power source and the power supply you intend to remove and remove the  
cables from the strap.  
2. Press the release latch and slide the power supply out of the chassis.  
Figure 40. Removing and Installing an AC Power Supply  
1.  
2.  
3.  
4.  
connector  
power supply  
release latch  
power supply handle  
77  
 
Installing An AC Power Supply  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Verify that both the power supplies are the same type and have the same maximum output power.  
NOTE: The maximum output power (shown in Watts) is listed on the power supply label.  
2. If applicable, remove the power supply blank.  
3. Slide the new power supply into the chassis until the power supply is fully seated and the release latch snaps into  
place.  
NOTE: If you unlatched the cable management arm, re-latch it. For information about the cable management  
arm, see the system’s rack documentation.  
4. Connect the power cable to the power supply and plug the cable into a power outlet.  
CAUTION: When connecting the power cable, secure the cable with the strap.  
NOTE: When installing, hot-swapping, or hot-adding a new power supply, allow several seconds for the  
system to recognize the power supply and determine its status. The power-supply status indicator turns green  
to signify that the power supply is functioning properly.  
Wiring Instructions For A DC Power Supply  
Your system supports up to two –(48–60) V DC power supplies (when available).  
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections  
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All  
electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that  
is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the  
product.  
CAUTION: Wire the unit with copper only, unless otherwise specified, use only 10 American Wire Gauge (AWG)  
wire rated minimum 90 ºC for source and return. Protect the –(48–60) V DC (1 wire) with a branch circuit over-  
current protection rated 50 A for DC with a high interrupt current rating.  
NOTE: A readily accessible disconnect device that is suitably approved and rated shall be incorporated in the field  
wiring.  
Input Requirements  
Supply voltage: –(48–60) V DC  
Current consumption: 32 A (maximum)  
Kit Contents  
Dell part number 6RYJ9 terminal block or equivalent (1)  
#6-32 nut equipped with lock washer (1)  
Required Tools  
Wire-stripper pliers capable of removing insulation from size 10 AWG solid or stranded, insulated copper wire  
78  
   
NOTE: Use alpha wire part number 3080 or equivalent (65/30 stranding)  
Required Wires  
One UL 10 AWG, 2 m maximum (stranded) black wire [–(48–60) V DC]  
One UL 10 AWG, 2 m maximum (stranded) red wire (V DC return)  
One UL 10 AWG, 2 m maximum green/yellow, green with a yellow stripe, stranded wire (safety ground)  
Assembling And Connecting The Safety Ground Wire  
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections  
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All  
electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that  
is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the  
product.  
1. Strip the insulation from the end of the green/yellow wire, exposing approximately 4.5 mm (0.175 inch) of copper  
wire.  
2. Using a hand-crimping tool (Tyco Electronics, 58433-3 or equivalent), crimp the ring-tongue terminal (Jeeson  
Terminals Inc., R5-4SA or equivalent) to the green/yellow wire (safety ground wire).  
3. Connect the safety ground wire to the grounding post on the back of the system using a #6-32 nut equipped with a  
locking washer.  
Figure 41. Assembling and Connecting the Safety Ground Wire  
1. safety ground wire  
2. grounding post  
3. locking washer  
4. spring washer  
5. #6-32 nut  
79  
Assembling The DC Input Power Wires  
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections  
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All  
electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that  
is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the  
product.  
1. Strip the insulation from the ends of the DC power wires, exposing approximately 13 mm (0.5 inch) of copper wire.  
WARNING: Reversing polarity when connecting DC power wires can permanently damage the power supply  
or the system.  
2. Insert the copper ends into the mating connectors and tighten the captive screws at the top of the mating  
connector using a #2 Phillips screwdriver.  
WARNING: To protect the power supply from electrostatic discharge, the captive screws must be covered  
with the rubber cap before inserting the mating connector into the power supply.  
3. Rotate the rubber cap clockwise to fix it over the captive screws.  
4. Insert the mating connector into the power supply.  
Figure 42. Assembling the DC Input Power Wires  
1. DC power socket  
2. rubber cap  
5. wire –48 V  
6. wire RTN  
3. captive screws (2)  
4. DC power connector  
7. grounding wire  
80  
Removing A DC Power Supply  
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections  
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All  
electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that  
is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the  
product.  
CAUTION: The system requires one power supply for normal operation. On power-redundant systems, remove and  
replace only one power supply at a time in a system that is powered on.  
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with power supply  
removal. For information about the cable management arm, see the system’s rack documentation.  
1. Disconnect the power wires from the power source and the connector from the power supply you intend to  
remove.  
2. Disconnect the safety ground wire.  
3. Press the release latch and slide the power supply out of the chassis.  
Figure 43. Removing and Installing a DC Power Supply  
1. connector  
4. release latch  
2. power supply  
5. power supply handle  
3. power supply status indicator  
Installing A DC Power Supply  
WARNING: For equipment using –(48–60) V DC power supplies, a qualified electrician must perform all connections  
to DC power and to safety grounds. Do not attempt connecting to DC power or installing grounds yourself. All  
electrical wiring must comply with applicable local or national codes and practices. Damage due to servicing that  
is not authorized by Dell is not covered by your warranty. Read and follow all safety instructions that came with the  
product.  
1. Verify that both the power supplies are the same type and have the same maximum output power.  
81  
   
NOTE: The maximum output power (shown in Watts) is listed on the power supply label.  
2. If applicable, remove the power supply blank.  
3. Slide the new power supply into the chassis until the power supply is fully seated and the release latch snaps into  
place.  
NOTE: If you unlatched the cable management arm, re-latch it. For information about the cable management  
arm, see the system’s rack documentation.  
4. Connect the safety ground wire.  
5. Install the DC power connector in the power supply.  
CAUTION: When connecting the power wires, secure the wires with the strap to the power supply handle.  
6. Connect the wires to a DC power source.  
NOTE: When installing, hot-swapping, or hot-adding a new power supply, allow several seconds for the  
system to recognize the power supply and determine its status. The power-supply status indicator turns green  
to signify that the power supply is functioning properly.  
Removing The Power Supply Blank  
CAUTION: To ensure proper system cooling, the power supply blank must be installed in the second power supply  
bay in a non-redundant configuration. Remove the power supply blank only if you are installing a second power  
supply.  
If you are installing a second power supply, remove the power supply blank in the bay by pulling outward on the  
blank.  
Figure 44. Removing and Installing the Power Supply Blank  
1.  
power supply blank  
Installing The Power Supply Blank  
NOTE: Install the power supply blank only in the second power supply bay.  
To install the power supply blank, align the blank with the power supply bay and insert it into the chassis until it clicks  
into place.  
82  
   
Removing The Power-Distribution And Power-Interposer Boards  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals  
2. Disconnect the power cable from the power source and the power supply you intend to remove, and remove the  
cables from the strap.  
3. Open the system.  
4. Disconnect all the power cables from the power supply to the system board, hard drives, and optical drive.  
CAUTION: The power-distribution and the power-interposer board assembly must be removed from the  
system before separating them to avoid damaging the power-distribution board's bottom layout.  
5. Remove the screws securing the power-distribution board to the chassis.  
6. Keeping the release tab pressed, slide the power-interposer and power-distribution board assembly up and toward  
the cooling fan, and lift it out of the system.  
7. Pull the power-distribution board out from the power-distribution board connector on the power-interposed board.  
Figure 45. Removing and Installing the Power-Distribution Board  
1. power-distribution board  
2. fan 6 cable connector  
83  
 
3. screws (4)  
6. power-distribution board connector  
4. power-interposer board  
5. release tab  
Figure 46. Power-Distribution Board Connectors  
1.  
2.  
3.  
fan 6 cable connector  
power-distribution board connector  
8-pin power connector  
84  
Figure 47. Power-Interposer Board Connectors  
1.  
2.  
3.  
8-pin power connector  
retaining slots (4)  
power-distribution board connector  
Installing The Power-Distribution And Power-Interposer Boards  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Unpack the new power-distribution and power-interposer boards.  
2. Open the system.  
3. Connect the power-distribution board to the power-interposer board outside the system  
CAUTION: To avoid damaging the power-distribution board's bottom layout, always connect the power-  
distribution board to the power-interposer board outside the system.  
4. Slide the power-interposer and power-distribution board assembly into the retaining hooks and push the boards  
downward until it clicks into position.  
5. Install the four screws that secure the power-distribution board to the chassis.  
6. Connect the power-distribution cables to the system board, the fan cable to the power-distribution board, and the  
power cable to the power-interposer board.  
7. Install the power supplies in the system.  
8. Close the system.  
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
85  
 
Removing A Non-Redundant Power Supply  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: You may have to unlatch and lift the optional cable management arm if it interferes with power supply  
removal. For information about the cable management arm, see the system’s rack documentation.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals  
2. Disconnect the power cable from the power source and the power supply you intend to remove, and remove the  
cables from the strap.  
3. Open the system.  
4. Disconnect the power cables from the power supply to the system board, and the hard-drive backplane.  
5. Remove the screw securing the power supply to the standoff on the chassis.  
6. Slide the power supply out of the chassis and away from the system.  
86  
 
Figure 48. Removing and Installing a Non-Redundant Power Supply  
1. chassis screw  
5. power cable (24 pins)  
2. power supply unit cage  
3. power supply  
6. power cable (8 pins)  
7. hard-drive backplane power cable  
4. standoff on the chassis  
87  
Installing A Non-Redundant Power Supply  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Unpack the new non-redundant power supply unit.  
2. Open the system.  
3. Slide the new power supply into the chassis until the screw hole on the power supply unit aligns with the standoff  
on the chassis.  
4. Tighten the screw to secure the power supply to the standoff on the chassis.  
5. Connect the power cable to the power supply.  
6. Connect the power distribution cables to the system board, and the hard-drive backplane.  
NOTE: Route the hard-drive backplane power cable through the FAN1 slot's fan blank.  
7. Close the system.  
8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Removing The Redundant Power Supply Unit Divider  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals  
2. Disconnect the power cable from the power source and the power supplies, and remove the cables from the strap.  
3. Remove the redundant power supplies.  
4. Open the system.  
5. Remove the screw securing the redundant power supply unit divider to the power supply unit cage.  
6. Slide the redundant power supply unit divider out, push it down, and slide it out of the power supply unit cage.  
88  
   
Figure 49. Removing and Installing the Redundant Power-Supply Unit Divider  
1. power supply unit divider alignment notches  
(3)  
2. power supply unit divider alignment tabs (3)  
3. redundant power supply unit divider  
4. power supply unit cage screw  
5. power supply unit cage  
Installing The Redundant Power Supply Unit Divider  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals  
2. Disconnect the power cable from the power source and the power supplies, and remove the cables from the strap.  
3. Open the system.  
4. Disconnect all the power cables from the power supply to the system board, hard drives and optical drive.  
89  
 
5. Remove the non-redundant power supplies from the system.  
6. Install the redundant power supply unit divider:  
a) Slide the redundant power supply unit divider into the power supply unit cage.  
b) Align the power supply unit divider with the notches on the power supply unit cage.  
c) Push the power supply unit divider up, and slide it into the power supply unit cage.  
d) Install the screw to secure the redundant power supply unit divider to the power supply unit cage.  
7. Install the redundant power supplies in the system.  
8. Connect the power-distribution cables to the system board, the fan cable to the power-distribution board, and the  
power cable to the power-interposer board.  
9. Close the system.  
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
System Battery  
Replacing The System Battery  
WARNING: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with  
the same or equivalent type recommended by the manufacturer. See your safety information for additional  
information.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
2. Open the system.  
Figure 50. Replacing the System Battery  
1.  
2.  
system battery  
battery connector  
3. Locate the battery socket.  
CAUTION: To avoid damage to the battery connector, you must firmly support the connector while installing or  
removing a battery.  
90  
   
4. To remove the battery, press down firmly on the positive side of the connector and lift the battery out of the  
securing tabs at the negative side of the connector.  
5. To install a new system battery, hold the battery with the "+" facing up and slide it under the securing tabs at the  
positive side of the connector.  
6. Press the battery straight down into the connector until it snaps into place.  
7. Close the system.  
8. Reconnect the system to the electrical outlet and turn the system on, including any attached peripherals  
9. Enter System Setup to confirm that the battery is operating properly.  
10. Enter the correct time and date in the System Setup's Time and Date fields.  
11. Exit System Setup.  
Hard-Drive Backplane  
Removing The Hard-Drive Backplane  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If installed, remove the front bezel.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
3. Open the system.  
CAUTION: To prevent damage to the hard drives and hard-drive backplane, you must remove the hard drives  
from the system before removing the hard-drive backplane.  
CAUTION: You must note the number of each hard drive and temporarily label them before removal so that  
you can replace them in the same locations.  
4. Remove all hard drives.  
5. Disconnect the SAS/SATA/SSD data cable(s) and power cable from the hard-drive backplane.  
6. Disconnect the power/data cable from the control panel board.  
7. Press the hard-drive backplane blue release tabs in the direction of the arrows to disengage the backplane from  
the chassis.  
8. Pull the hard-drive backplane away from the system until the securing hooks on the hard-drive backplane are free  
from the slots on the chassis.  
91  
   
Figure 51. Removing and Installing the Hard-Drive Backplane  
1. securing hooks  
2. securing slot  
6. backplane power connector  
7. SAS B connector  
3. release tabs (2)  
4. SAS A connector  
5. backplane signal connector  
8. hard-drive backplane  
9. hard-drive connectors (8)  
92  
Figure 52. Cabling Diagram of the Hard-Drive Backplane for a Redundant PSU System  
1. system board  
6. SAS A cable connector  
2. hard-drive backplane  
3. SAS B cable connector  
4. power cable connector  
5. signal cable connector  
7. cable routing guide  
8. power distribution board  
9. cable retention latch  
93  
Figure 53. Cabling Diagram of the Hard-Drive Backplane for a Non-Redundant PSU System  
1. system board  
7. cable routing guide  
8. FAN1 slot  
9. cable retention latch  
10. non-redundant power supply  
2. hard-drive backplane  
3. SAS B cable connector  
4. power cable connector  
5. signal cable connector  
6. SAS A cable connector  
Installing The Hard-Drive Backplane  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Holding the blue release tabs, align the slots on the hard-drive backplane with the securing hooks on the chassis.  
2. Push the hard-drive backplane down until the release tabs snap into place.  
3. Attach the SAS A cable to the SAS A connector, and the SAS B cable to the SAS B connector on the hard-drive  
backplane.  
4. Connect the power cable(s) to the hard-drive backplane.  
5. Route the power/data cables along the chassis wall.  
6. Install the hard drives in their original locations.  
7. Close the system.  
8. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
94  
 
9. If applicable, install the front bezel.  
Control Panel Assembly  
Removing The Control-Panel Board  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If installed, remove the front bezel.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
3. Open the system.  
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab  
on the connector is released before removal and insertion. The locking tab must be engaged after insertion.  
4. Disconnect the USB cable, control panel cable, and the display module cable from the control-panel board.  
5. Using a #2 Phillips screwdriver, remove the two screws that secure the control-panel board to the chassis.  
6. Slide the control-panel board toward the back and lift it out of the system.  
Figure 54. Removing and Installing the Control-Panel Board  
1.  
2.  
3.  
control-panel board  
screws (2)  
control-panel data cable  
95  
   
4.  
USB cable  
Installing The Control-Panel Board  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Align the screw holes on the control-panel board with the standoffs on the chassis.  
2. Using a #2 Phillips screwdriver, replace the two screws that secure the control-panel board to the chassis.  
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab  
on the connector is released before removal and insertion. The locking tab must be engaged after insertion.  
3. Connect the USB cable, control panel cable, and the display module cable to the control-panel board.  
4. Route the power/data cables through the cable retention bracket.  
5. Close the system.  
6. If applicable, install the front bezel.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
Removing The Control Panel  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If installed, remove the front bezel.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet and  
peripherals.  
3. Open the system.  
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab  
on the connector is released before removal and insertion. The locking tab must be engaged after insertion.  
4. Disconnect the display module cable from the control-panel board.  
NOTE: The control panel has six tabs that secure it to the chassis.  
CAUTION: Applying excessive force may damage the control panel.  
5. Hold the top edge of the control panel at the corners and pull upward until the control panel tabs release.  
6. Pull the control panel away from the chassis.  
96  
   
1.  
2.  
notches on chassis front wall (6)  
control panel  
Installing The Control Panel  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Slide the left side of the control panel into the chassis so that the left tab on the control panel aligns with the slot on  
the chassis wall and the top left tab aligns with the slot on the top of the chassis.  
2. Pull the display module cable through the opening and into the chassis.  
3. Push the right side of the control panel until the top right tab aligns with the top of the chassis and the control panel  
snaps into place.  
CAUTION: The display module connector is a ZIF (zero insertion force) connector. Ensure that the locking tab  
on the connector is released before removal and insertion. The locking tab must be engaged after insertion.  
4. Connect the display module cable to the control panel board.  
5. Close the system.  
6. If applicable, install the front bezel.  
7. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
System Board  
97  
   
Removing The System Board  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: If you are using the Trusted Program Module (TPM) with an encryption key, you may be prompted to  
create a recovery key during program or System Setup. Be sure to create and safely store this recovery key. If you  
replace this system board, you must supply the recovery key when you restart your system or program before you  
can access the encrypted data on your hard drives.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
2. If installed, remove the front bezel.  
3. Open the system.  
4. Remove the following:  
a) If installed, full length expansion card on slot 2 of expansion-card riser 2  
b) cooling shroud  
c) memory modules  
WARNING: The memory modules are hot to touch for some time after the system has been powered  
down. Allow time for the memory modules to cool before handling them. Handle the memory modules by  
the card edges and avoid touching the components on the memory module.  
d) power supply(s)  
e) expansion cards  
f) integrated storage controller card  
g) expansion-card risers  
WARNING: The heat sink is hot to touch for some time after the system has been powered down. Ensure  
that you do not touch the heat sink(s) while removing the system board.  
h) internal dual SD module  
CAUTION: To avoid damaging the mini SAS cable and connector, follow the correct procedure when  
removing the mini SAS cable from the system board.  
5. Disconnect the mini SAS cable from the system board:  
a) Push the mini SAS cable connector to slide it further into the connector (SAS_A) on the system board.  
b) Press down and hold the metal tab on the mini SAS cable connector.  
c) Pull the mini SAS cable out of the connector on the system board.  
98  
 
a. mini SAS cable connector  
b. metal tab  
c. connector on the system board  
6. Disconnect all other cables from the system board.  
CAUTION: Take care not to damage the system identification button while removing the system board from  
the chassis.  
7. Remove the system battery.  
8. Grasp the system-board holder, slide the system board toward the front of the system, and lift the system board out  
of the chassis.  
CAUTION: Do not lift the system board assembly by grasping a memory module, processor, or other  
components.  
Figure 55. Removing and Installing the System Board  
1.  
2.  
3.  
release screws (9)  
system board holder  
system board  
Installing The System Board  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Unpack the new system board assembly.  
CAUTION: Do not lift the system board assembly by grasping a memory module, processor, or other  
components.  
99  
 
CAUTION: Take care not to damage the system identification button while placing the system board into the  
chassis.  
2. Holding the system board holder, lower the system board into the chassis.  
3. Push the system board toward the back of the chassis until the board clicks into place.  
4. Install the system battery.  
5. Replace the following:  
a) internal dual SD module  
b) expansion cards and the integrated storage controller card  
c) expansion-card risers  
d) power supply(s)  
e) memory modules  
f) cooling shroud  
g) If installed, full length expansion card on slot 2 of expansion-card riser 2  
6. Connect the cables to the system board.  
7. Route the power/data cables through the cable retention bracket.  
8. Close the system.  
9. If applicable, install the front bezel.  
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
11. Import your new or existing iDRAC Ports license. For more information, see iDRAC7 User's Guide, at dell.com/  
support/manuals.  
100  
4
Troubleshooting Your System  
Safety First—For You And Your System  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
Troubleshooting System Startup Failure  
If you boot the system to the BIOS boot mode after installing an operating system from the UEFI Boot Manager, the  
system hangs. The reverse is also true. You must boot to the same boot mode in which you installed the operating  
system.  
For all other startup issues, note the system messages that appear on the screen.  
Troubleshooting External Connections  
Ensure that all external cables are securely attached to the external connectors on your system before troubleshooting  
any external devices.  
Troubleshooting The Video Subsystem  
1. Check the system and power connections to the monitor.  
2. Check the video interface cabling from the system to the monitor.  
3. Run the appropriate diagnostic test.  
If the tests run successfully, the problem is not related to video hardware.  
If the tests fail, see Getting Help.  
Troubleshooting A USB Device  
Use the following steps to troubleshoot a USB keyboard/mouse. For other USB devices, go to step 7.  
1. Disconnect the keyboard and mouse cables from the system briefly and reconnect them.  
2. Connect the keyboard/mouse to the USB port(s) on the opposite side of the system.  
3. If the problem is resolved, restart the system, enter the System Setup, and check if the non-functioning USB ports  
are enabled.  
4. Replace the keyboard/mouse with another working keyboard/mouse.  
5. If the problem is resolved, replace the faulty keyboard/mouse.  
6. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to  
the system.  
101  
           
7. Power down all attached USB devices and disconnect them from the system.  
8. Restart the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are  
enabled on the Integrated Devices screen, in the System Setup options.  
If your keyboard is not functioning, you can also use remote access. If the system is not accessible, reset the  
NVRAM_CLR jumper inside your system and restore the BIOS to the default settings.  
9. Reconnect and power on each USB device one at a time.  
10. If a device causes the same problem, power down the device, replace the USB cable with a known good cable, and  
power up the device.  
If all troubleshooting fails, see Getting Help.  
Troubleshooting A Serial I/O Device  
1. Turn off the system and any peripheral devices connected to the serial port.  
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.  
If the problem is resolved, replace the interface cable with a known good cable.  
3. Turn off the system and the serial device, and swap the device with a comparable device.  
4. Turn on the system and the serial device.  
If the problem persists, see Getting Help.  
Troubleshooting A NIC  
1. Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.  
2. Restart the system and check for any system messages pertaining to the NIC controller.  
3. Check the appropriate indicator on the NIC connector:  
If the link indicator does not light, check all cable connections.  
If the activity indicator does not light, the network driver files might be damaged or missing.  
Remove and reinstall the drivers if applicable. See the NIC's documentation.  
If applicable, change the autonegotiation setting.  
Use another connector on the switch or hub.  
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.  
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.  
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and  
duplex. See the documentation for each network device.  
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.  
If all troubleshooting fails, see Getting Help.  
102  
   
Troubleshooting A Wet System  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
3. Disassemble components from the system:  
Hard drives  
Hard-drive backplane  
USB memory key  
Cooling shroud  
Expansion-card risers (if present)  
Expansion cards  
Power supply(s)  
Cooling-fan assembly (if present)  
Cooling fans  
Processor(s) and heat sink(s)  
Memory modules  
4. Let the system dry thoroughly for at least 24 hours.  
5. Reinstall the components you removed in step 3.  
6. Close the system.  
7. Turn on the system and attached peripherals.  
If the system does not start properly, see Getting Help.  
8. If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed.  
9. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
If the tests fail, see Getting Help.  
Troubleshooting A Damaged System  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
3. Ensure that the following components are properly installed:  
Cooling shroud  
Expansion-card risers (if present)  
Expansion cards  
Power supply(s)  
103  
   
Cooling-fan assembly (if present)  
Cooling fans  
Processor(s) and heat sink(s)  
Memory modules  
Hard-drive carriers  
Hard-drive backplane  
4. Ensure that all cables are properly connected.  
5. Close the system.  
6. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
If the tests fail, see Getting Help.  
Troubleshooting The System Battery  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system  
configuration information. This situation is caused by a defective battery.  
1. Re-enter the time and date in the System Setup.  
2. Turn off the system and disconnect it from the electrical outlet for at least one hour.  
3. Reconnect the system to the electrical outlet and turn on the system.  
4. Enter the System Setup.  
If the date and time are not correct in the System Setup, check the SEL for system battery messages.  
If the problem is not resolved, see Getting Help.  
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate  
normally except for the time kept in the System Setup, the problem may be caused by software rather than by a  
defective battery.  
Troubleshooting Power Supplies  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Reseat the power supply by removing and reinstalling it.  
NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply  
and to determine if it is working properly.  
2. If the problem persists, see Getting Help.  
104  
   
Troubleshooting Cooling Problems  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
Ensure that none of the following conditions exist:  
System cover, cooling shroud, EMI filler panel, memory-module blank, or back-filler bracket is removed.  
Ambient temperature is too high.  
External airflow is obstructed.  
A cooling fan is removed or has failed.  
The expansion card installation guidelines have not been followed.  
Troubleshooting Cooling Fans  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Open the system.  
2. Reseat the fan or the fan's power cable.  
3. If the fan functions properly, close the system.  
If the problem persists, see Getting Help.  
Troubleshooting System Memory  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. If the system is operational, run the appropriate diagnostic test. See Using System Diagnostics for available  
diagnostic tests.  
If diagnostics indicates a fault, follow the corrective actions provided by the diagnostic program.  
2. If the system is not operational, turn off the system and attached peripherals, and unplug the system from the  
power source. Wait at least 10 seconds and then reconnect the system to power.  
3. Turn on the system and attached peripherals and note the messages on the screen.  
If an error message is displayed indicating a fault with a specific memory module, go to step 12.  
4. Enter the System Setup and check the system memory setting. Make any changes to the memory settings, if  
needed.  
If the memory settings match the installed memory but a problem is still indicated, go to step 12.  
5. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
6. Open the system.  
7. Check the memory channels and ensure that they are populated correctly.  
105  
     
8. Reseat the memory modules in their sockets.  
9. Close the system.  
10. Enter the System Setup and check the system memory setting.  
If the problem is not resolved, proceed with the next step.  
11. Open the system.  
12. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module  
with a known good memory module.  
13. To troubleshoot an unspecified faulty memory module, replace the memory module in the first DIMM socket with a  
module of the same type and capacity.  
If an error message is displayed on the screen, this may indicate a problem with the installed DIMM type(s),  
incorrect DIMM installation, or defective DIMM(s). Follow the on-screen instructions to resolve the problem. For  
more information, see General Memory Module Installation Guidelines.  
14. Close the system.  
15. As the system boots, observe any error message that is displayed and the diagnostic indicators on the front of the  
system.  
16. If the memory problem is still indicated, repeat step 12 through step 15 for each memory module installed.  
If the problem persists after all memory modules have been checked, see Getting Help.  
Troubleshooting An Internal USB Key  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Enter the System Setup and ensure that the USB key port is enabled from the Integrated Devices screen.  
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
3. Open the system.  
4. Locate the USB key and reseat it.  
5. Close the system.  
6. Turn on the system and attached peripherals and check if the USB key is functioning.  
7. If the problem is not resolved, repeat step 2 and step 3.  
8. Insert a different USB key that you know works properly.  
9. Close the system.  
If the problem is not resolved, see Getting Help.  
Troubleshooting An SD Card  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
106  
   
NOTE: Certain SD cards have a physical write-protect switch on the card. If the write-protect switch is turned on  
then the SD card is not writeable.  
1. Enter the System Setup and ensure that the Internal SD Card Port is enabled.  
2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
3. Open the system.  
CAUTION: If the Internal SD Card Redundancy option is set to Mirror Mode in the Integrated Devices screen  
of the System Setup, you must follow the instructions in step 4 through step 7 to avoid loss of data.  
NOTE: When an SD card failure occurs, the internal dual SD module controller notifies the system. On the next  
reboot, the system displays a message indicating the failure.  
4. If the Internal SD Card Redundancy option is set to Disabled, replace the failed SD card with a new SD card.  
5. If SD card 1 has failed, remove the card from SD card slot 1. If SD card 2 has failed, install a new SD card in SD  
card slot 2 and proceed to step 7.  
6. Remove the card present in SD card slot 2 and insert it into SD card slot 1.  
7. Insert the new SD card into SD card slot 2.  
8. Close the system.  
9. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
10. Enter the System Setup and ensure that the Internal SD Card Port and Internal SD Card Redundancy mode is  
enabled.  
11. Check if the SD card is functioning properly.  
If the problem persists, see Getting Help.  
Troubleshooting An Optical Drive  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Try using a different CD or DVD.  
2. Enter the System Setup and ensure that the integrated SATA controller and the drive's SATA port are enabled.  
3. Run the appropriate diagnostic test.  
4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
5. Open the system.  
6. Remove the front bezel.  
7. Ensure that the interface cable is securely connected to the optical drive and to the controller.  
8. Ensure that a power cable is properly connected to the drive.  
9. Close the system.  
If the problem is not resolved, see Getting Help.  
107  
 
Troubleshooting A Hard Drive  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
CAUTION: This troubleshooting procedure can erase data stored on the hard drive. Before you proceed, back up  
all files on the hard drive.  
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
Depending on the results of the diagnostics test, proceed as needed through the following steps.  
2. If your system has a RAID controller and your hard drives are configured in a RAID array, perform the following  
steps:  
a) Restart the system and press <F10> during system startup to run the Lifecycle Controller, and then run the  
Hardware Configuration wizard to check the RAID configuration.  
See the Lifecycle Controller documentation or online help for information on RAID configuration.  
b) Ensure that the hard drive(s) have been configured correctly for the RAID array.  
c) Take the hard drive offline and reseat the drive.  
d) Exit the configuration utility and allow the system to boot to the operating system.  
3. Ensure that the required device drivers for your controller card are installed and are configured correctly. See the  
operating system documentation for more information.  
4. Restart the system and enter the System Setup.  
5. Verify that the controller is enabled and the drives are displayed in the System Setup.  
If the problem persists, try troubleshooting the expansion cards or see Getting Help.  
Troubleshooting A Storage Controller  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: When troubleshooting a SAS or PERC controller, also see the documentation for your operating system and  
the controller.  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
Open the system.  
Verify that the installed expansion cards are compliant with the expansion card installation guidelines.  
Ensure that each expansion card is firmly seated in its connector.  
Close the system  
Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  
If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the  
electrical outlet.  
9.  
Open the system.  
10. Remove all expansion cards installed in the system.  
108  
   
11. Close the system.  
12. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.  
13. Run the appropriate diagnostic test. For more information, see Using System Diagnostics. If the tests fail, see  
14. For each expansion card you removed in step 10, perform the following steps:  
a. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
b. Open the system.  
c. Reinstall one of the expansion cards.  
d. Close the system.  
e. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
If the tests fail, see Getting Help.  
Troubleshooting Expansion Cards  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the  
expansion card.  
1. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
3. Open the system.  
4. Ensure that each expansion card is firmly seated in its connector.  
5. Close the system.  
6. If the problem is not resolved, turn off the system and attached peripherals, and disconnect the system from the  
electrical outlet.  
7. Open the system.  
8. Remove all expansion cards installed in the system.  
9. Close the system.  
10. Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
If the tests fail, see Getting Help.  
11. For each expansion card you removed in step 8, perform the following steps:  
a) Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
b) Open the system.  
c) Reinstall one of the expansion cards.  
d) Close the system.  
e) Run the appropriate diagnostic test. For more information, see Using System Diagnostics.  
If a problem is still indicated, see Getting Help.  
109  
 
Troubleshooting Processors  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Run the appropriate diagnostics test. See Using System Diagnostics for available diagnostic tests.  
2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.  
3. Open the system.  
4. Ensure that the processor and heat sink are properly installed.  
5. Close the system.  
6. Run the appropriate diagnostic test. For more information , see Using System Diagnostics.  
If a problem is still indicated, see Getting Help.  
110  
 
5
Using System Diagnostics  
If you experience a problem with your system, run the system diagnostics before contacting Dell for technical  
assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional  
equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the  
diagnostics results to help you solve the problem.  
Dell Online Diagnostics  
Dell Online Diagnostics, a stand-alone suite of diagnostic programs or test modules, allows you to run diagnostic tests  
on the systems in a production environment, and helps you ensure maximum uptime of your systems. Online Diagnostics  
allows you to run diagnostic tests on chassis and storage components such as hard drives, physical memory, and  
network interface cards (NICs). You can use the graphical user interface (GUI) or the command line interface (CLI) to run  
diagnostic tests on the hardware that Online Diagnostics discovers on your system. For information about using  
diagnostics, see the Dell Online PowerEdge Diagnostics User’s Guide under Software Serviceability Tools, at  
dell.com/support/manuals.  
Dell Embedded System Diagnostics  
NOTE: Also known as Enhanced Pre-boot System Assessment (ePSA) diagnostics.  
The embedded system diagnostics provides a set of options for particular device groups or devices allowing you to:  
Run tests automatically or in an interactive mode  
Repeat tests  
Display or save test results  
Run thorough tests to introduce additional test options to provide extra information about the failed device(s)  
View status messages that inform you if tests are completed successfully  
View error messages that inform you of problems encountered during testing  
When To Use The Embedded System Diagnostics  
If a major component or device in the system does not operate properly, running the embedded system diagnostics may  
indicate component failure.  
Running The Embedded System Diagnostics  
The embedded system diagnostics program is run from the Dell Lifecycle Controller.  
CAUTION: Use the embedded system diagnostics to test only your system. Using this program with other systems  
may cause invalid results or error messages.  
1. As the system boots, press <F11>.  
2. Use the up and down arrow keys to select System Utilities Launch Dell Diagnostics .  
111  
         
The ePSA Pre-boot System Assessment window is displayed, listing all devices detected in the system. The  
diagnostics starts executing the tests on all the detected devices.  
System Diagnostic Controls  
Menu  
Description  
Configuration  
Results  
Displays the configuration and status information of all detected devices.  
Displays the results of all tests that are executed.  
Provides the current overview of the system performance.  
System Health  
Event Log  
Displays a time-stamped log of the results of all tests run on the system. This is displayed if at  
least one event description is recorded.  
For information about embedded system diagnostics, see the Dell Enhanced Pre-boot System Assessment User Guide at  
dell.com/support/manuals.  
112  
 
6
Jumpers And Connectors  
System Board Jumper Settings  
For information on resetting the password jumper to disable a password, see Disabling A Forgotten Password.  
Table 5. System Board Jumper Settings  
Jumper  
Setting  
Description  
PWRD_EN  
The password feature is enabled (pins 2–4).  
(default)  
(default)  
The password feature is disabled (pins 4–6). iDRAC local  
access is unlocked at the next AC power cycle.  
NVRAM_CLR  
The configuration settings are retained at system boot  
(pins 3–5).  
The configuration settings are cleared at the next system  
boot (pins 1–3).  
113  
   
System Board Connectors  
Figure 56. System Board Connectors and Jumpers  
Item  
1
Connector  
INT_STORAGE  
ID_BTN  
CMA_JACK  
USB 2  
Description  
Storage controller card connector  
System identification button  
System identification connector  
USB connector  
2
3
4
5
USB 1  
USB connector  
6
IO_RISER2  
NIC2  
Riser 2 connector  
7
Network connector  
Network connector  
Video connector  
8
NIC1  
9
VGA  
10  
11  
12  
13  
14  
COM  
Serial connector  
BATTERY  
IO_RISER1  
CPU2  
Battery connector  
Riser 1 connector  
Processor socket 2  
Cooling fan connector  
FAN6  
114  
 
Item  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Connector  
FAN5  
Description  
Cooling fan connector  
Memory module sockets  
Cooling fan connector  
Cooling fan connector  
8-pin power connector  
Cooling fan connector  
Memory module sockets  
Backplane signal connector  
24-pin power connector  
Processor socket 1  
B1, B4, B2, B5, B3, B6  
FAN4  
FAN3  
PWR_CONN_1  
FAN2  
A1, A4, A2, A5, A3, A6  
BP_SIG  
PWR_CONN_2  
CPU1  
PDB_CONN  
SATA_A-D  
CTRL_PNL_MB  
SATA_E  
Power distribution board connector  
SATA connector A to D  
Control panel interface connector  
Optical drive SATA connector  
Front panel USB connector  
Mini-SAS connector  
FP_USB  
SAS_A  
IDSDM  
Internal Dual SD Module  
Mini-SAS connector  
SAS_B  
Disabling A Forgotten Password  
The system's software security features include a system password and a setup password. The password jumper  
enables these password features or disables them and clears any password(s) currently in use.  
CAUTION: Many repairs may only be done by a certified service technician. You should only perform  
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or  
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your  
warranty. Read and follow the safety instructions that came with the product.  
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
2. Open the system.  
3. Move the jumper on the system-board jumper from pins 4 and 6 to pins 2 and 4.  
4. Close the system.  
The existing passwords are not disabled (erased) until the system boots with the Jumper on pins 2 and 4. However,  
before you assign a new system and/or setup password, you must move the jumper back to pins 4 and 6.  
NOTE: If you assign a new system and/or setup password with the jumper on pins 2 and 4, the system disables  
the new password(s) the next time it boots.  
5. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
6. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.  
115  
 
7. Open the system.  
8. Move the jumper on the system-board jumper from pins 2 and 4 to pins 4 and 6.  
9. Close the system.  
10. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.  
11. Assign a new system and/or setup password.  
116  
7
Technical Specifications  
Processor  
Processor type  
One or two Intel Xeon processor E5-2400 and E5-2400 v2  
product family  
Expansion Bus  
Bus type  
PCI Express Generation 2 and Generation 3  
Expansion slots using riser card for a one processor  
system:  
Riser 1  
Riser 2  
(Slot 1) One half-height, half-length x4 link with x8 slot  
(Slot 2) One full-height, full-length x8 link with x16 slot  
(Slot 3) One full-height, half-length x4 link with x8 slot  
(Slot 4) One full-height, half-length x4 link with x8 slot  
Expansion slots using riser card for a two processor  
system:  
Riser 1  
Riser 2  
(Slot 1) One half-height, half-length x16 link with x16 slot  
(Slot 2) One full-height, full-length x8 link with x16 slot  
(Slot 3) One full-height, half-length x8 link with x16 slot  
(Slot 4) One full-height, half-length x8 link with x16 slot  
NOTE: If you install a second processor, you must:  
remove the dummy fan from the FAN6 slot  
install a cooling fan in the FAN6 slot  
upgrade both the expansion-card risers (riser 1  
and riser 2)  
Memory  
Architecture  
1600 MT/s, 1333 MT/s, or 1066 MT/s DDR3 and LV-DDR3  
DIMMs  
Memory module sockets  
Memory module capacities  
RDIMMs  
Twelve 240-pin  
2 GB (single-rank), 4 GB (single- and dual-rank), 8 GB  
(dual-rank), 16 GB (dual-rank), and 32 GB (quad-rank)  
UDIMMs  
2 GB (single-rank) and 4 GB (dual-rank)  
117  
 
Memory  
Minimum RAM  
Maximum RAM  
2 GB (single processor configuration)  
384 GB  
Drives  
Up to eight 3.5 inch or 2.5 inch, internal, hot-swappable  
SAS, SATA, SAS SSD. SATA SSD, or Nearline SAS hard  
drives in hard-drive slots 0 through 7.  
Hard drives  
Up to four 3.5 inch or 2.5 inch, internal, hot-swappable  
SAS, SATA, SAS SSD, SATA SSD, or Nearline SAS hard  
drives in hard-drive slots 0 through 3 for a software RAID  
system.  
Optical drive  
One optional slimline SATA DVD-ROM or DVD+/-RW  
drive  
NOTE: DVD devices are data only.  
Connectors  
Back  
NIC  
Two RJ-45 10/100/1000 Mbps  
9-pin, DTE, 16550-compatible  
Two 4-pin, USB 2.0-compliant  
15-pin VGA  
Serial  
USB  
Video  
iDRAC7 (Optional)  
External vFlash card (Optional)  
One 1GbE Ethernet port  
vFlash memory card  
NOTE: The card slot is available for use only if the  
iDRAC7 Enterprise license is installed on your  
system.  
Front  
USB  
Two 4-pin, USB 2.0-compliant  
15-pin VGA  
Video  
Internal  
USB  
One 4-pin, USB 2.0-compliant  
Internal Dual SD Module (IDSDM)  
Two optional flash memory card slots with the internal SD  
module  
NOTE: One card slot is dedicated for redundancy.  
118  
Video  
Video type  
Video memory  
Integrated Matrox G200  
16 MB shared  
Expanded Operating Temperature  
NOTE: When operating in the expanded temperature range, system performance may be impacted.  
NOTE: When operating in the expanded temperature range, ambient temperature warnings may be reported on  
the LCD and in the System Event Log.  
< 10% of annual operating hours  
5 °C to 40 °C at 5% to 85% RH with 26 °C dew point.  
NOTE: Outside the standard operating temperature  
(10 °C to 35 °C), the system can operate down to 5 °C  
or up to 40 °C for a maximum of 10% of its annual  
operating hours.  
For temperatures between 35 °C and 40 °C, de-rate  
maximum allowable dry bulb temperature by 1 °C per 175  
m above 950 m (1 °F per 319 ft).  
< 1% of annual operating hours  
–5 °C to 45 °C at 5% to 90% RH with 26 °C dew point.  
NOTE: Outside the standard operating temperature  
(10 °C to 35 °C), the system can operate down to –5  
°C or up to 45 °C for a maximum of 1% of its annual  
operating hours.  
For temperatures between 40 °C and 45 °C, de-rate  
maximum allowable dry bulb temperature by 1 °C per 125  
m above 950 m (1 °F per 228 ft).  
Expanded Operating Temperature Restrictions  
Do not perform a cold startup below 5 °C.  
Allow processor performance degrade.  
Non-redundant power supplies are not supported.  
Non Dell qualified peripheral cards and/or peripheral  
cards greater than 25 W are not supported.  
Maximum altitude for the operating temperature must  
be 3050 m (10,000 ft).  
Environmental  
NOTE: For additional information about environmental measurements for specific system configurations, see  
dell.com/environmental_datasheets.  
Temperature  
Maximum Temperature Gradient (Operating and Storage) 20 °C/h (36 °F/h)  
Storage Temperature Limits  
–40 °C to 65 °C (–40 °F to 149 °F)  
Temperature (Continuous Operation)  
119  
Environmental  
Temperature Ranges (for altitude less than 950 m or 3117 10 °C to 35 °C (50 °F to 95 °F) with no direct sunlight on  
ft)  
the equipment.  
Humidity Percentage Range  
10% to 80% Relative Humidity with 26 °C (78.8 °F)  
maximum dew point.  
Relative Humidity  
Storage  
5% to 95% RH with 33 °C (91 °F) maximum dew point.  
Atmosphere must be non-condensing at all times.  
Maximum Vibration  
Operating  
0.26 Grms at 5 Hz to 350 Hz (all operation orientations).  
Storage  
1.87 Grms at 10 Hz to 500 Hz for 15 min (all six sides  
tested).  
Maximum Shock  
Operating  
One shock pulse in the positive z axis of 31 G for 2.6 ms  
in all operational orientations.  
Storage  
Six consecutively executed shock pulses in the  
positive and negative x, y, and z axes (one pulse on  
each side of the system) of 71 G for up to 2 ms.  
Maximum Altitude  
Operating  
3048 m (10,000 ft).  
12,000 m (39,370 ft).  
Storage  
Operating Altitude De-rating  
Up to 35 °C (95 °F)  
Maximum temperature is reduced by 1 °C/300 m (1  
°F/547 ft) above 950 m (3,117 ft).  
35 °C to 40 °C (95 °F to 104 °F)  
40 °C to 45 °C (104 °F to 113 °F)  
Particulate Contamination  
Maximum temperature is reduced by 1 °C/175 m (1  
°F/319 ft) above 950 m (3,117 ft).  
Maximum temperature is reduced by 1 °C/125 m (1  
°F/228 ft) above 950 m (3,117 ft).  
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and  
gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits  
specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you  
to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of  
environmental conditions will be the responsibility of the customer.  
Air Filtration  
NOTE: Applies to data center environments only. Air  
Data center air filtration as defined by ISO Class 8 per  
ISO 14644-1 with a 95% upper confidence limit.  
filtration requirements do not apply to IT equipment  
designed to be used outside a data center, in  
environments such as an office or factory floor.  
NOTE: Air entering the data center must have  
MERV11 or MERV13 filtration.  
120  
Environmental  
Conductive Dust  
NOTE: Applies to data center and non-data center  
environments.  
Air must be free of conductive dust, zinc whiskers, or  
other conductive particles.  
Corrosive Dust  
Air must be free of corrosive dust.  
Residual dust present in the air must have a  
deliquescent point less than 60% relative humidity.  
NOTE: Applies to data center and non-data center  
environments.  
Gaseous Contamination  
NOTE: Maximum corrosive contaminant levels measured at 50% relative humidity.  
Copper Coupon Corrosion Rate  
Silver Coupon Corrosion Rate  
<300 Å/month per Class G1 as defined by ANSI/  
ISA71.04-1985.  
<200 Å/month as defined by AHSRAE TC9.9.  
121  
122  
8
System Messages  
LCD Messages  
NOTE: Applicable only if your system has an LCD display.  
The LCD messages consist of brief text messages that refer to events recorded in the System Event Log (SEL). For  
information on the SEL and configuring system management settings, see the systems management software  
documentation.  
NOTE: If your system fails to boot, press the System ID button for at least 5 seconds until an error code is displayed  
on the LCD. Record the code, then see System Error Messages.  
Viewing LCD Messages  
If a system error occurs, the LCD screen will turn amber. Press the Select button to view the list of errors or status  
messages. Use the Left and Right buttons to highlight an error number, and press the Select button to view the error.  
Removing LCD Messages  
For faults associated with sensors, such as temperature, voltage, fans, and so on, the LCD message is automatically  
removed when that sensor returns to a normal state. For other faults, you must take action to remove the message from  
the display:  
Clear the SEL — You can perform this task remotely, but you will lose the event history for the system.  
Power cycle — Turn off the system and disconnect it from the electrical outlet; wait approximately 10 seconds,  
reconnect the power cable, and restart the system.  
System Error Messages  
System messages appear on the monitor to notify you of a possible problem with the system. These messages refer to  
events recorded in the System Event Log (SEL). For information on the SEL and configuring system management settings,  
see the systems management software documentation.  
Some messages are also displayed in an abbreviated form on the system's LCD, if the system includes that feature.  
NOTE: The LCD error messages listed here are displayed in the simple format. See Setup Menu to select the format  
in which the messages are displayed.  
NOTE: If you receive a system message not listed here, check the documentation of the application that was  
running when the message was displayed or the operating system's documentation for an explanation of the  
message and recommended action.  
NOTE: In some messages, a particular system component is identified by name (“<name>”) component number  
(“<number>”), or location (“bay”).  
123  
         
Error Code  
AMP0302  
Message Information  
Message  
The system board <name> current is greater than the upper warning  
threshold.  
Details  
Action  
System board <name> current is outside of the optimum range.  
1.  
2.  
3.  
4.  
Review system power policy.  
Check system logs for power related failures.  
Review system configuration changes.  
If the issue persists, see Getting Help.  
AMP0303  
Message  
The system board <name> current is greater than the upper critical  
threshold.  
LCD Message  
Details  
System board <name> current is outside of range.  
System board <name> current is outside of the optimum range.  
Action  
1.  
2.  
3.  
4.  
Review system power policy.  
Check system logs for power related failures.  
Review system configuration changes.  
If the issue persists, see Getting Help.  
ASR0000  
ASR0001  
ASR0002  
Message  
Details  
The watchdog timer expired.  
The operating system or an application failed to communicate within  
the time-out period.  
Action  
Check the operating system, application, hardware, and system event  
log for exception events.  
Message  
Details  
The watchdog timer reset the system.  
The operating system or an application failed to communicate within  
the time-out period. The system was reset.  
Action  
Check the operating system, application, hardware, and system event  
log for exception events.  
Message  
Details  
The watchdog timer powered off the system.  
The operating system or an application failed to communicate within  
the time-out period. The system was shut down.  
Action  
Check the operating system, application, hardware, and system event  
log for exception events.  
124  
Error Code  
ASR0003  
Message Information  
Message  
Details  
The watchdog timer power cycled the system.  
The operating system or an application failed to communicate within  
the time-out period. The system was power-cycled.  
Action  
Check the operating system, application, hardware, and system event  
log for exception events.  
BAT0002  
BAT0017  
Message  
LCD Message  
Details  
The system board battery has failed.  
The system board battery has failed. Check battery.  
The system board battery is either missing or bad.  
See Getting Help.  
Action  
Message  
LCD Message  
Details  
The <name> battery has failed.  
The <name> battery has failed. Check battery.  
The <name> battery is either missing, bad, or unable to charge due to  
thermal issues.  
Action  
Check system fans. If the problem persists, see Getting Help.  
CPU0000  
CPU0001  
CPU0005  
Message  
LCD Message  
Details  
CPU <number> has an internal error (IERR).  
CPU <number> has an internal error (IERR).  
System Event Log and Operating System Logs may indicate that the  
exception is external to the processor.  
Action  
Review System Event Log and Operating System Logs. If the issue  
persists, see Getting Help.  
Message  
LCD Message  
Details  
CPU <number> has a thermal trip (over-temperature) event.  
CPU <number> has a thermal trip. Check CPU heat sink.  
The processor temperature increased beyond the operational range.  
Action  
Review the logs for fan failures. If no fan failures are detected, check  
inlet temperature (if available) and reinstall processor heat sink. If the  
problem persists, see Getting Help.  
Message  
CPU <number> configuration is unsupported.  
LCD Message  
CPU <number> configuration is unsupported. Check CPU or BIOS  
revision.  
Details  
System is unable to boot or may run in a degraded state.  
125  
Error Code  
CPU0010  
Message Information  
Action  
Review the technical specifications for supported processor types.  
Message  
Details  
Action  
CPU <number> is throttled.  
The CPU is throttled due to thermal or power conditions.  
Review system logs for power or thermal exceptions.  
CPU0023  
CPU0204  
Message  
LCD Message  
Action  
CPU <number> is absent.  
CPU <number> is absent. Check CPU.  
Verify processor installation. If present, re-seat the processor.  
Message  
LCD Message  
Details  
CPU <number> <name> voltage is outside of range.  
CPU <number> <name> voltage is outside of range. Re-seat CPU.  
Voltages outside the allowable range may damage electrical  
components or may cause the system to shutdown.  
Action  
1.  
2.  
3.  
4.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
If the issue persists, see Getting Help.  
CPU0700  
Message  
LCD Message  
Details  
CPU <number> initialization error detected.  
CPU <number> initialization error detected. Power cycle system.  
System BIOS was unable to initialize the processor.  
Action  
1.  
2.  
3.  
4.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
If the issue persists, see Getting Help.  
CPU0701  
Message  
LCD Message  
Details  
CPU <number> protocol error detected.  
CPU <number> protocol error detected. Power cycle system.  
System event log and operating system logs may indicate that the  
exception is external to the processor.  
Action  
1.  
Check system and operating system logs for exceptions. If no  
exceptions are found, continue.  
126  
Error Code  
Message Information  
2.  
3.  
4.  
5.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
If the issue persists, see Getting Help.  
CPU0702  
Message  
LCD Message  
Details  
CPU bus parity error detected.  
CPU bus parity error detected. Power cycle system.  
System event log and operating system logs may indicate that the  
exception is external to the processor.  
Action  
1.  
Check system and operating system logs for exceptions. If no  
exceptions are found, continue.  
2.  
3.  
4.  
5.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
If the issue persists, see Getting Help.  
CPU0703  
Message  
LCD Message  
Details  
CPU bus initialization error detected.  
CPU bus initialization error detected. Power cycle system.  
System event log and operating system logs may indicate that the  
exception is external to the processor.  
Action  
1.  
Check system and operating system logs for exceptions. If no  
exceptions are found, continue.  
2.  
3.  
4.  
5.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
If the issue persists, see Getting Help.  
CPU0704  
Message  
LCD Message  
Details  
CPU <number> machine check error detected.  
CPU <number> machine check error detected. Power cycle system.  
System event log and operating system logs may indicate that the  
exception is external to the processor.  
Action  
1.  
Check system and operating system logs for exceptions. If no  
exceptions are found, continue.  
2.  
3.  
4.  
Turn off the system and remove input power for one minute.  
Ensure the processor is seated correctly.  
Reapply input power and turn on the system.  
127  
Error Code  
FAN0000  
Message Information  
5.  
If the issue persists, see Getting Help.  
Message  
Details  
Action  
Fan <number> RPM is less than the lower warning threshold.  
Fan operating speed is out of range.  
Remove and reinstall the fan. If the issue persists, see Getting Help.  
FAN0001  
FAN1201  
HWC1001  
Message  
LCD Message  
Details  
Fan <number> RPM is less than the lower critical threshold.  
Fan <number> RPM is outside of range. Check fan.  
Fan operating speed is out of range.  
Action  
Remove and reinstall the fan. If the issue persists, see Getting Help.  
Message  
LCD Message  
Details  
Fan redundancy is lost.  
Fan redundancy is lost. Check fans.  
Fan has failed.  
Action  
Remove and reinstall failed fans or install additional fans.  
Message  
LCD Message  
Details  
The <name> is absent.  
The <name> is absent. Check hardware.  
The absent device may be necessary for proper operation. System  
functionality may be degraded.  
Action  
Reinstall or reconnect the hardware.  
HWC2003  
Message  
The storage <name> cable is not connected, or is improperly  
connected.  
LCD Message  
Details  
Storage <name> cable or interconnect failure. Check connection.  
The cable may be necessary for proper operation. System  
functionality may be degraded.  
Action  
Check if the cable is present, then reinstall or reconnect.  
HWC2005  
Message  
The system board <name> cable is not connected, or is improperly  
connected.  
LCD Message  
Details  
System board <name> cable connection failure. Check connection.  
The cable may be necessary for proper operation. System  
functionality may be degraded.  
128  
Error Code  
MEM0000  
Message Information  
Action  
Check if the cable is present, then reinstall or reconnect.  
Message  
Persistent correctable memory errors detected on a memory device  
at location(s) <location>.  
Details  
Action  
This is an early indicator of a possible future uncorrectable error.  
Re-seat the memory modules. If the issue persists, see Getting Help .  
MEM0001  
Message  
Multi-bit memory errors detected on a memory device at location(s)  
<location>.  
LCD Message  
Details  
Multi-bit memory error on <location>. Re-seat memory.  
The memory module has encountered an uncorrectable error. System  
performance may be degraded. The operating system and/or  
applications may fail as a result.  
Action  
Re-seat the memory modules. If the issue persists, see Getting Help.  
MEM0007  
Message  
Unsupported memory configuration; check memory device at location  
<location>.  
LCD Message  
Details  
Unsupported memory configuration. Check memory <location>.  
The memory may not be seated correctly, misconfigured, or has  
failed. Memory size is reduced.  
Action  
Check the memory configuration. Re-seat the memory modules. If the  
issue persists, see Getting Help.  
MEM0701  
MEM0702  
Message  
Details  
Correctable memory error rate exceeded for <location>.  
The memory may not be operational. This an early indicator of a  
possible future uncorrectable error.  
Action  
Re-seat the memory modules. If the issue persists, see Getting Help.  
Message  
Correctable memory error rate exceeded for <location>.  
LCD Message  
Correctable memory error rate exceeded for <location>. Re-seat  
memory.  
Details  
Action  
The memory may not be operational. This an early indicator of a  
possible future uncorrectable error.  
Re-seat the memory modules. If the issue persists, see Getting Help.  
MEM1205  
Message  
Memory mirror redundancy is lost. Check memory device at  
location(s) <location>.  
129  
Error Code  
Message Information  
LCD Message  
Details  
Memory mirror lost on <location>. Power cycle system.  
The memory may not be seated correctly, misconfigured, or has  
failed.  
Action  
Check the memory configuration. Re-seat the memory modules. If the  
issue persists, see Getting Help.  
MEM1208  
MEM8000  
Message  
Memory spare redundancy is lost. Check memory device at location  
<location>.  
LCD Message  
Details  
Memory spare lost on <location>. Power cycle system.  
Memory sparing is no longer available.  
Action  
Re-seat the memory modules. If the issue persists, see Getting Help.  
Message  
Correctable memory error logging disabled for a memory device at  
location <location>.  
LCD Message  
Details  
SBE log disabled on <location>. Re-seat memory.  
Errors are being corrected but no longer logged.  
Action  
Review system logs for memory exceptions. Reinstall memory at  
location <location>.  
PCI1302  
Message  
Details  
Action  
A bus time-out was detected on a component at bus <bus>  
device<device> function <func>.  
System performance may be degraded. The device has failed to  
respond to a transaction.  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
PCI1304  
PCI1308  
Message  
LCD Message  
Action  
An I/O channel check error was detected.  
I/O channel check error detected. Power cycle system.  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
Message  
LCD Message  
Details  
A PCI parity error was detected on a component at bus  
<bus>device<device>function <func>.  
PCI parity error on bus <bus> device <device> function <func>.  
Power cycle system.  
System performance may be degraded, PCI device may fail to  
operate, or system may fail to operate.  
130  
Error Code  
PCI1320  
Message Information  
Action  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
Message  
A bus fatal error was detected on a component at bus  
<bus>device<device>function <func>.  
LCD Message  
Bus fatal error on bus <bus> device <device> function <func>. Power  
cycle system.  
Details  
Action  
System performance may be degraded, or system may fail to operate.  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
PCI1342  
PCI1348  
Message  
Details  
Action  
A bus time-out was detected on a component at slot <number>.  
System performance may be degraded, or system may fail to operate.  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
Message  
LCD Message  
Details  
A PCI parity error was detected on a component at slot <number>.  
PCI parity error on slot <number>. Re-seat PCI card.  
System performance may be degraded, or system may fail to operate.  
Action  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
PCI1360  
Message  
LCD Message  
Details  
A bus fatal error was detected on a component at slot <number>.  
Bus fatal error on slot <number>. Re-seat PCI card.  
System performance may be degraded, or system may fail to operate.  
Action  
Cycle input power, update component drivers, if device is removable,  
reinstall the device.  
PDR0001  
Message  
LCD Message  
Details  
Fault detected on drive <number>.  
Fault detected on drive <number>. Check drive.  
The controller detected a failure on the disk and has taken the disk  
offline.  
Action  
Remove and re-seat the failed disk. If the issue persists, see Getting  
Help.  
PDR1016  
Message  
Drive <number> is removed from disk drive bay <bay>.  
131  
Error Code  
Message Information  
LCD Message  
Details  
Drive <number> removed from disk drive bay <bay>. Check drive.  
The controller detected that the drive was removed.  
Action  
Verify drive installation. Re-seat the failed drive. If the issue persists,  
see Getting Help.  
PST0128  
PST0129  
Message  
LCD Message  
Details  
No memory is detected.  
No memory is detected. Inspect memory devices.  
System BIOS was unable to detect memory in the system.  
Re-seat the memory modules. If the issue persists, see Getting Help.  
Action  
Message  
LCD Message  
Details  
Memory is detected, but is not configurable.  
Memory is detected, but is not configurable. Check memory devices.  
System BIOS detected memory, but was unable to configure the  
memory for system operation.  
Action  
Compare system memory installation to supported system memory  
configurations.  
PSU0001  
PSU0002  
Message  
LCD Message  
Action  
Power supply <number> failed.  
PSU <number> failed. Check PSU.  
Remove and reinstall the power supply. If the issue persists, see  
Message  
LCD Message  
Details  
A predictive failure detected on power supply <number>.  
Predictive failure on PSU <number>. Check PSU.  
System performance and power redundancy may be degraded or  
lost.  
Action  
Remove and reinstall the power supply at the next service window. If  
the issue persists, see Getting Help.  
PSU0003  
Message  
LCD Message  
Details  
The power input for power supply <number> is lost.  
Power input for PSU <number> is lost. Check PSU cables.  
The power supply is installed correctly but an input source is not  
connected or is not functional.  
Action  
Verify the input source is attached to the power supply. Verify the  
input power is within the operating requirements for the power  
supply.  
132  
Error Code  
PSU0006  
Message Information  
Message  
LCD Message  
Details  
Power supply <number> type mismatch.  
Power supply <number> is incorrectly configured. Check PSU.  
Power supplies should be of the same input type and power rating.  
Action  
Install matched power supplies and review proper configuration in  
this manual.  
PSU0016  
Message  
LCD Message  
Details  
Power supply <number> is absent.  
PSU <number> is absent. Check PSU.  
The power supply has been removed or has failed.  
Action  
1.  
2.  
Remove and reinstall the power supply.  
Check cables and subsystem components in the system for  
damage.  
3.  
If the issue persists, see Getting Help.  
PSU0031  
Message  
LCD Message  
Details  
Cannot communicate with power supply <number>.  
Cannot communicate with PSU <number>. Re-seat PSU.  
The power supply may operate, however power supply monitoring is  
degraded. System performance may be degraded.  
Action  
Remove and reinstall the power supply. If the issue persists, see  
PSU0032  
PSU0033  
Message  
Details  
Action  
The temperature for power supply <number> is in a warning range.  
System performance may be degraded.  
Check the system operating environment, including airflow and inlet  
temperature. Check system logs for temperature and thermal  
component failures.  
Message  
The temperature for power supply <number> is outside of the  
allowable range.  
LCD Message  
Details  
PSU <number> temperature outside of range. Check PSU.  
System performance may be degraded.  
Action  
Check the system operating environment, including airflow and inlet  
temperature. Check system logs for temperature and thermal  
component failures.  
133  
Error Code  
PSU0034  
Message Information  
Message  
An under voltage fault detected on power supply <number>.  
LCD Message  
An under voltage fault detected on PSU <number>. Check power  
source.  
Details  
Action  
This failure may be the result of an electrical issue with cables or  
subsystem components in the system.  
1.  
2.  
Remove and reinstall the power supply.  
Check cables and subsystem components in the system for  
damage.  
3.  
If the issue persists, see Getting Help.  
PSU0035  
PSU0036  
Message  
LCD Message  
Action  
An over voltage fault detected on power supply <number>.  
Over voltage fault on PSU <number>. Check PSU.  
Check input power or reinstall the power supply. If the issue persists,  
see Getting Help.  
Message  
LCD Message  
Details  
An over current fault detected on power supply <number>.  
An over current fault detected on PSU <number>. Check PSU.  
This failure may be the result of an electrical issue with cables or  
subsystem components in the system.  
Action  
1.  
2.  
Remove and reinstall the power supply.  
Check cables and subsystem components in the system for  
damage.  
3.  
If the issue persists, see Getting Help.  
PSU0037  
PSU0076  
Message  
LCD Message  
Action  
Fan failure detected on power supply <number>.  
Fan failure detected on PSU <number>. Check PSU.  
Check for fan blockage. If the problem persists, see Getting Help.  
Message  
A power supply wattage mismatch is detected; power supply  
<number> is rated for <value> watts.  
LCD Message  
Details  
PSU wattage mismatch; PSU <number> = <value >watts  
Power supplies should be of the same input type and power rating.  
Action  
Install matched power supplies and review this manual for proper  
configuration.  
134  
Error Code  
PSU1201  
Message Information  
Message  
Details  
Power supply redundancy is lost.  
The power supply tries to operate in a degraded state. System  
Performance and power redundancy may be degraded or lost.  
Action  
Check input power. Reinstall the power supply. If the issue persists,  
see Getting Help.  
PSU1204  
Message  
The power supplies are not redundant. Insufficient resources to  
maintain normal operations.  
LCD Message  
Details  
PSU redundancy degraded. Check PSU cables.  
The current power operational mode is non-redundant because of a  
power supply exception, a power supply inventory change, or a  
system power inventory change.  
Action  
Check the event log for power supply failures. Review system  
configuration and power consumption.  
PWR1004  
Message  
Details  
Action  
The system performance degraded because power capacity has  
changed.  
The system may power down or operate in a performance degraded  
state.  
Check the event log for power supply failures. Review system  
configuration and power consumption and upgrade or install power  
supplies accordingly.  
PWR1005  
PWR1006  
Message  
The system performance degraded because the user-defined power  
capacity has changed.  
Details  
Action  
The user-defined power settings have affected system operation.  
If unintended, review system configuration changes and power  
policy.  
Message  
LCD Message  
Details  
The system halted because system power exceeds capacity.  
System power demand exceeds capacity. System halted.  
The system halted because system power exceeds capacity.  
Action  
Review system configuration, upgrade power supplies or reduce  
system power consumption.  
RFM1008  
Message  
Failure detected on Removable Flash Media <name>.  
Removable Flash Media <name> failed. Check SD Card.  
LCD Message  
135  
Error Code  
RFM1014  
Message Information  
Details  
An error was reported during a SD card read or write.  
Action  
Reseat the flash media. If the problem persists, see Getting Help.  
Message  
LCD Message  
Details  
Removable Flash Media <name> is write protected.  
Removable Flash Media <name> is write protected. Check SD Card.  
The card is write-protected by the physical latch on the SD card. A  
write-protected card cannot be used.  
Action  
If unintended, remove the media and disable write protection.  
RFM1201  
RFM2001  
Message  
LCD Message  
Details  
Internal Dual SD Module redundancy is lost.  
Internal Dual SD Module redundancy is lost. Check SD Card.  
Either one or both the SD cards are not functioning properly.  
See Getting Help.  
Action  
Message  
LCD Message  
Details  
Internal Dual SD Module <name> is absent.  
Internal Dual SD Module <name> is absent. Check SD Card.  
The SD card module is not detected or not installed.  
If unintended, reinstall the SD module.  
Action  
RFM2002  
RFM2004  
Message  
Details  
Internal Dual SD Module <name> is offline.  
The SD card module is installed but may be improperly installed or  
configured incorrectly.  
Action  
Reinstall the SD module.  
Message  
LCD Message  
Details  
Failure detected on Internal Dual SD Module <name>.  
Internal Dual SD Module <name> failed. Check SD Card.  
The SD card module is installed but improperly configured or failed to  
initialize.  
Action  
Reinstall the SD module and remove and reinstall SD cards.  
RFM2006  
Message  
Details  
Internal Dual SD Module <name> is write protected.  
The module is write-protected. Changes may not be written to the  
media.  
Action  
If unintended, remove the media and disable write protection.  
136  
Error Code  
SEC0031  
Message Information  
Message  
LCD Message  
Details  
The chassis is open while the power is on.  
Intrusion detected. Check chassis cover.  
The chassis is open. System performance may be degraded, and  
security may be compromised.  
Action  
Close the chassis. Check system logs.  
SEC0033  
Message  
LCD Message  
Details  
The chassis is open while the power is off.  
Intrusion detected. Check chassis cover.  
The chassis was opened while the power was off. System security  
may have been compromised.  
Action  
Close the chassis and verify hardware inventory. Check system logs.  
SEL0006  
SEL0008  
Message  
Details  
All event logging is disabled.  
This message is displayed when all event logging has been disabled  
by the user.  
Action  
If unintended, re-enable logging.  
Message  
Details  
Log is full.  
When the event log is full, additional events are not written to the log.  
Older events may be overwritten and lost. This message may also  
appear if the user disabled event logging.  
Action  
Backup and clear log.  
SEL0012  
Message  
Details  
Could not create or initialize the system event log.  
If the system event log fails to initialize, platform status and failure  
events are not captured. Some management software do not report  
platform exceptions.  
Action  
Reboot the management controller or iDRAC. Cycle system input  
power. If problem persists call support.  
SEL1204  
Message  
LCD Message  
Details  
An unknown system hardware failure detected.  
Unknown system hardware failure.  
If the system event log failed to initialize, platform status and failure  
events are not captured. Some management software do not report  
platform exceptions.  
137  
Error Code  
TMP0118  
Message Information  
Action  
Re-configure system to the minimum supported configuration. If  
issues persists, contact support.  
Message  
The system inlet temperature is less than the lower warning  
threshold.  
LCD Message  
Details  
System inlet temperature is outside of range.  
Ambient air temperature is too cool.  
Action  
Check the system operating environment.  
TMP0119  
TMP0120  
Message  
LCD Message  
Details  
The system inlet temperature is less than the lower critical threshold.  
System inlet temperature is outside of range.  
Ambient air temperature is too cool.  
Action  
Check the system operating environment.  
Message  
The system inlet temperature is greater than the upper warning  
threshold.  
LCD Message  
Details  
System inlet temperature is outside of range.  
Ambient air temperature is too warm or one or more fans may have  
failed.  
Action  
Check the system operating environment and review event log for fan  
failures.  
TMP0121  
Message  
The system inlet temperature is greater than the upper critical  
threshold.  
LCD Message  
Details  
System inlet <name> temperature is outside of range. Check Fans.  
Ambient air temperature is too warm or one or more fans may have  
failed.  
Action  
Check the system operating environment and review event log for fan  
failures.  
VLT0204  
Message  
LCD Message  
Details  
The system board <name> voltage is outside of the allowable range.  
System board voltage is outside of range.  
System hardware detected an over voltage or under voltage  
condition.  
If multiple voltage exceptions occur consecutively the system may  
power down in fail-safe mode.  
138  
Error Code  
Message Information  
Action  
1.  
2.  
Review system logs for power supply exceptions.  
Re-configure the system to minimum configuration, inspect and  
reinstall system cables.  
3.  
If the issue persists, see Getting Help.  
Warning Messages  
A warning message alerts you to a possible problem and prompts you to respond before the system continues a task.  
For example, before you format a hard drive, a message warns you that you may lose all data on the hard drive. Warning  
messages usually interrupt the task and require you to respond by typing y (yes) or n (no).  
NOTE: Warning messages are generated by either the application or the operating system. For more information,  
see the documentation that accompanied the operating system or application.  
Diagnostic Messages  
The system diagnostic utilities may issue messages if you run diagnostic tests on your system. See “Using System  
Diagnostics” chapter for more information about system diagnostics.  
Alert Messages  
Systems management software generates alert messages for your system. Alert messages include information, status,  
warning, and failure messages for drive, temperature, fan, and power conditions. For more information, see the systems  
management software documentation.  
139  
     
140  
9
Getting Help  
Contacting Dell  
NOTE: If you do not have an active Internet connection, you can find contact information on your purchase invoice,  
packing slip, bill, or Dell product catalog.  
Dell provides several online and telephone-based support and service options. Availability varies by country and  
product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer  
service issues:  
1. Visit dell.com/support  
2. Select your support category.  
3. Verify your country or region in the Choose a Country/Region drop-down menu at the top of page.  
4. Select the appropriate service or support link based on your need.  
141  
   

Motorola MOTOROKR 6803632F58 User Manual
Maxtor DIAMONDMAXTMPLUS6800 91707U5 User Manual
Logitech Wireless Rechargeable Touchpad T650 User Manual
Lenovo ThinkCentre 41N5583 User Manual
JVC KD G207 User Manual
iHome IH B934NB User Manual
Hitachi Travelstar HTS547575A9E381 User Manual
Gemini CDX 402 User Manual
Centon electronic DataStick Bolt 16GBDSB BLACK User Manual
Belkin F4D517 User Manual