Xerox All in One Printer 130 B 141 User Manual

 
FreeFlow Accxes  
Customer Release Notes  
Version 13.0 b 141  
(for 6279 only)  
Contents  
2 Introduction  
2 Feature Keys  
3 Release Deliverables  
4 Recommended Configurations  
5 Release Installation  
6 New Features  
7 Release Notes  
15 Customer Issues Resolved  
December, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Release Deliverables  
Xerox 6279 Wide Format Solution  
The following executable is provided for the Xerox 6279 Wide Format Solution and supports the Xerox Wide  
Format Scan System and GFI finisher.  
FRX & LVX Controller:  
FRX_LVX_6279_13_0b141.disk.bin (file size = 54,615,971 bytes)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Recommended Configurations  
The following table specifies the RAM requirements for the various systems and configurations supported by the  
FreeFlow Accxes controller.  
FRX Controller  
Recommend  
LVX Controller  
Recommend  
2GB  
System  
Min  
Min  
Any System with the following  
feature keys:  
2GB 2GB  
2GB  
AutoCAD  
OtherCAD  
RASTER  
6279  
2GB 2GB  
2GB  
2GB  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Release Installation  
This version of Accxes (13.0 b 141) requires OS Install CD version 4.1 or higher. BSP Kernel revision 2.6.22.9-  
61.fc6 or later is also required. Service is required to upgrade from earlier Accxes® revisions.  
Regarding scanner firmware revisions: If you are upgrading the firmware of a system containing a Xerox Wide  
Format Scanner, you must also ensure that the scanner firmware is upgraded, prior to upgrading the controller,  
to the following version:  
IMPORTANT NOTE: The controller will only accept the installation when there are no active jobs being  
processed.  
Accxes Client Tools  
Download the file named “<Controller>_<Printer>_<Accxes_version>.disk.bin”. A status sheet will be printed and  
indicate that the download was successful.  
Web Printer Management Tool  
Select Utilities > Upload > Upload File. Use the Browse button to select the  
“<Controller>_<Printer>_<Accxes_version>.disk.bin”. Click on the “Upload” button. A printed status sheet will  
indicate that the download was successful.  
Unix  
Download the software using LPR with the following command line:  
lpr –P printername “<Controller>_<Printer>_<Accxes_version>.disk.bin”  
A status sheet will be printed and indicate that the download was successful.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
New Features in FreeFlow Accxes version 13.0  
Support for 6279 Printer and Scanner and User Interface  
The 6279 includes a new color touch screen user interface. The user interface controls the scanner  
functionality as well as the printer queue and other print related functions.  
Scan to Remote Printer (TotalAccxes)  
The FreeFlow Accxes 13.0 release includes a new feature allowing the user to make a scan in any mode and have  
the resulting file print on a remote wide format printer.  
Printer support includes:  
FreeFlow Accxes based devices  
HP 4500PS (PostScript enabled 4500)  
Canon IPF700  
Xerox Wide Format 7142  
Workcenter Pro 55  
Workcenter 7345  
Scan to Multi-page TIF and PDF  
The FreeFlow Accxes 13.0 release includes the ability to create multi-page documents in TIFF or PDF in any  
of the supported document types.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Release Notes  
The following information supplements the 13.0 customer user guides  
Total Accxes  
An issue has been seen with submitting 150 and 200 dpi color and grayscale images to office printers.  
Submission of 300, 400 and 600 dpi images have been more reliable, though higher resolutions require  
monger processing times.  
Sets  
For 600 DPI engines (6279) the maximum number of ARCH E sized documents that will collate reliably in a set is  
150. If the documents will not collate properly, one copy of the set will be printed only. This is for sets created  
using the scanner as well as printed sets submitted across the network.  
Controller  
Stamp does not appear  
If the user tries to upload a stamp files that contains an invalid format, or if the Accounting Mode is set to  
“Enabled”, no error message will be displayed. The WebPMT screen will display a message that the file was  
uploaded successfully and the stamp’s filename will not appear in the “Printer Resident Stamps” list. To avoid this  
situation, set the Job Accounting mode to “Optional” before uploading stamps. The WebPMT has no knowledge  
of the validity of any file that is sent to the printer. File validation and error handling is done on the printer by the  
FreeFlow Accxes controller. The WebPMT only reports that the file was sent to the printer successfully.  
Scaling Interaction with “ANY”  
The media size “ANY” will select the best sheet size for an image to prevent clipping. If a user specifies a media  
size of “ANY” and a scale factor that makes the image too large for any sheet size and mismatch mode is set to  
scale, the controller will select the largest sheet size and scale the image to fit on it. If this is not the desired  
behavior, a specific sheet size can be selected, or the media mismatch mode can be set to QUERY.  
Margins may cause clipping  
If the margins (TOP, BOTTOM, RIGHT and LEFT) are set to a non-zero value (5mm is the default) then that  
amount of whitespace will be added to the image before placing it on the media and could cause part of the  
image to be shifted off the page, or clipped. To correct this problem set the margins to 0.  
CGM Files and Folding  
Certain CGM files contain rotation commands which can confuse the system when folding. If the title block is not  
visible or the plot is bypassed and not folded, change the title block location to obtain a correctly folded  
document.  
TFTP not operational beyond FreeFlow Accxes 12.7  
The Trivial File Transfer Protocol is not operational. The recommendation is to use the FreeFlow Accxes Client  
Tools for job submission to the FreeFlow Accxes controller running 12.7 or higher..  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Wide Format Scanner  
Copy Templates lost after reboot  
The copy and scan templates defined on a Wide Format Scan system will be lost after a power cycle.  
Clear Last Image  
When the “Clear Last Image” feature is selected on the Xerox Wide Format Scan System, it may take a few  
minutes for a Photo or Color mode scanned document to clear out. After scanning a document, this feature is  
accessed by selecting the “C” key on the scanner. It will bring up the “CLEAR SCANNED IMAGE” screen. Use the  
“Next” button to select “CLEAR LAST IMAGE”, and then press “ENTER”  
Invert Feature and Recall Last Job  
Scan a document. Press the Transform key. Select “Recall Last Job”. If the Invert feature (changes dark to light  
and vice versa) is selected before printing the recalled document, the document will not be inverted. It will need  
to be rescanned to get the inverted image.  
Scan to Print and Margins  
When performing a scan-to-print operation the scanned image is printed using the current printer processing  
defaults including margins. If the image scanned is exactly the width of the paper, then the processing default  
margins should be set to zero to prevent the image from being clipped or placed on a larger sheet of paper.  
Width Detection Sensors and Finishing  
When using the width detection sensors, if the document is a little bit off-center, this could cause problems for  
folding, as the document printed may be square. This is most problematic with A, B, and C sizes. Documents must  
be centered when using the sensors for width detection.  
Background Suppression  
The scanner uses the first few inches of a document to determine the background suppression. If the first few  
inches of the document being scanned are not representative of the entire document, either too much or too little  
of the background will be removed. If this occurs, try physically turning the document 90 degrees and scan it  
again. Continue with this until an edge is found that produces a good scan.  
 
Scaling Shaded Documents  
Scaling documents with error diffused shaded areas should be done in a photo mode to produce the best image  
quality. Line and normal modes tend to exaggerate the shading dots making them more visible.  
 
50000015 errors while copying  
Occasional 50000015 errors have been seen while scanning more than 128 documents on the 6030/6050 system.  
This happens when an experienced operator gets a significant number of pages ahead of the printer causing a  
queue that is larger than the system can hold. The solution is to wait for several of the pages to complete  
printing before copying any additional documents.  
Recalling sets  
When a set is recalled, the scanner UI settings are not set to reflect their state for the last page scaled, but are in  
a “neutral” state to prevent unintentional overriding of setting for the set. If a setting (like scale, page size, etc) is  
changed it will affect the entire document set.  
Washed out documents when scanning/copying  
When scanning/copying documents with very low contrast (like poor blue line or sepia documents) with dynamic  
background removal set to OFF can cause the system to threshold the document and produce a very washed out  
document. Enabling background removal will actually remove less of the background in this case.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Manual Feed  
Manual feed media source will be ignored when used with the Accxes Client Tools’ page composition  
feature  
Go to Accxes Client Tools > Job Option tab > Composition tab > Select Overlay Images > Media Source drop down  
menu. Although “Manual Feed” is listed as a choice of media source for page composition jobs, the print job will  
be treated as if AUTO media source was selected. If an appropriate roll of media is available, it will be printed on  
that media; otherwise, the job will query until the correct roll media is installed. In addition, other Media Source  
selections will be treated as AUTO if an appropriate roll of media is available in a different roll.  
InstantAccxes  
When using InstantAccxes folders on an IPv6 network you must reference the system directly as shown below:  
Vista: Start>Run> \\<Controller Name>  
Linux: smb://<Controller Name>  
InstantAccxes Folders not accessible from MAC on IPv6  
InstantAccxes folders are not accessible to systems running MAC OS 10.4 or earlier versions on IPv6 networks.  
Web Printer Management Tool  
Printer Queue – Main Web Printer Management Tool Screen  
The FreeFlow Accxes Controller supports a maximum of 120 active printer jobs in the queue and 8 active copy  
jobs. If subsequent jobs are sent before the 128th prints, ports will refuse connections and there can be scan  
errors; when there are fewer jobs in the queue, the jobs can then be resubmitted or scanned. Additionally,  
completed jobs will be removed from the queue display immediately to make room for the newly submitted print  
jobs. To avoid these issues, keep the number of active print jobs to under the 128 limit.  
NOTE: More than 128 files can be sent from the Document Submit Tool as one print job, but all of the files in the print job must  
have printed before sending subsequent jobs, or the jobs will be refused  
German users only  
Zum Drucken von Etiketten mit Umlauten DRUCKERVORGABEN > DRUCKER-EINSTELLUNG > Plot-Etiketten  
wählen. Anschließend im Dropdown-Menü für Fonts einen der folgenden Fonts wählen: HP2 Stick Font Latin - 1  
oder HP2 Stick font Latin - 1 – Proportional.  
 
Large Scaling Factors  
Images set to scale beyond the largest installed roll will not scale beyond the largest width unless a specific roll is  
selected, a specific page size is selected, or mismatch mode is set to something other than scaling. This is a  
behavior that has changed from previous releases (prior to 9.0).  
For example: The largest roll installed is 36". Scaling is set to 999%. Submit an ARCH E sized drawing (Media Size  
= Any, Mismatch = Scaling). The drawing will not be scaled.  
In order for the output to exhibit the desired scaling factor, one of the following conditions must be met:  
What to do:  
Set Mismatch Mode to Substitute  
Request a Media Size of ARCH E via Web Printer Management Tool, ACT, or the Driver  
Request a Media Size 36" Roll via Web Printer Management Tool, ACT, or the Driver  
 
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Web Printer Management Tool (continued)  
HPGL Page – End of File  
If the files are streamed via any port on the system, these are treated as a single job and no reset is done  
between them. However, if one uses the LPD protocol to send the files one at a time, the effect is that the printer  
is reset after each job. If the “Reinitialize after EOF” is set to be on, the FreeFlow Accxes firmware will reset the  
printing parameters after each plot file that is received by a serial port or a parallel port. To reset the HPGL  
parameters on the Web Printer Management Tool, select Printer Defaults > Emulations > HPGL. Click on the box  
in front of “Reinitialize after EOF”. Click on the “UPDATE PRINTER” button.  
Display of Media Usage  
The Web Printer Management Tool Linear Media Usage displays the Media Usage in METERS. The  
mechanical meters used on the Xerox Wide Format Print System 721p IOTs can be programmed using the  
IOT diagnostics and are determined by which mode (ANSI or ISO) that the IOT is programmed to operate  
in. The units of measurement may not be the same.  
Default PostScript Page Size  
If a PostScript job does not specify a page size (either by using a compatibility operator such as “letter”, or “a4”, or  
by using the setpagedevice operator /PageSize parameter), the page size used is the one specified by the Default  
PostScript Page Size parameter available via the printer user interface, or via the Web Printer Management Tool.  
“Printer has been updated” message  
If the user presses the “UPDATE PRINTER” button without actually making changes first, the Web Printer  
Management Tool will still return a message that the printer was updated. The Web Printer Management Tool  
cannot distinguish a page that has been modified from one that has not been modified. This is because of the  
“stateless” nature of the http protocol and the fact that no events are generated (html) when text values are  
entered or items are selected. When the “UPDATE PRINTER” button is pressed, all the data on the form is  
gathered and sent to the server. If the data is valid, the printer is updated and “The printer was updated  
successfully.” message is returned. If inappropriate data is sent, an error message is returned. To verify valid  
changes to printer settings, a test print can be printed to view the changed settings.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Disk Image Overwrite  
Overview  
The Disk Image Overwrite feature has two operations: Immediate and On Demand. The immediate operation  
overwrites image data on the hard drive immediately after it is no longer needed (i.e. When the page has printed).  
The On Demand operation cleans the entire disk. Both On Demand Image Overwrite and Immediate Image  
overwrite feature are configured by the system administrator, assuming that the system administrator password  
is set to a non-zero value.  
Algorithm  
The overwrite algorithm for both IIO and ODIO conforms to the U.S. Department of Defense Directive 5200.28-M  
(Section 7, Part 2, paragraph 7-202), and is common to all WorkCentre/WorkCentre Pros and Accxes controllers.  
The algorithm for the Image Overwrite feature is:  
Step 1: Pattern #1 is written to the sectors containing temporary files (IIO) or to the entire spooling area of the  
disk (ODIO). (hex value 0x35 (ASCII “5”)).  
Step 2: Pattern #2 is written to the sectors containing temporary files (IIO) or to the entire spooling area of the  
disk (ODIO). (hex value 0xCA (ASCII compliment of 5)).  
Step 3: Pattern #3 is written to the sectors containing temporary files (IIO) or to the entire spooling area of the  
disk (ODIO). (hex value 0x97 (ASCII “ú”)).  
Step 4: 10% of the overwritten area is sampled to ensure Pattern #3 was properly written. The 10% sampling is  
accomplished by sampling a random 10% of the overwritten area.  
See Online Help in Web Printer Management Tool for more details about using the Image Overwrite feature.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6279 Specific Notes  
Overview  
This section is clarification to the existing documentation available for the 6279 system.  
Timer Reset Button  
This button will reset the timer value to the previous setting, NOT to the factory default setting.  
Shared Settings  
Many of the setting for Scan-to-Mailbox and Scan-to-Network are shared and so many of the settings made on  
one will stay when selecting the other.  
Can’t interrupt multi-page/set operations  
When creating a collated copy set or a multi-page scan file you cannot leave the Service to enter another service  
like machine info to change administration settings. To allow the user to do so would force an abort of the  
current scanned job or potentially change a setting which should have applied to all pages and so produce an  
inconsistent set.  
Speeding up Remote Print Times  
When scanning a document to a remote printer it is important to use an appropriate resolution for the  
application. A 600 dpi scan in full color will take significantly longer to process than a 200 or 300 dpi scan.  
Unless the application warrants a high resolution scan, it is recommended that 200-300 dpi be used to increase  
productivity.  
Installing and removing feature keys  
The 6279 system must be in an idle state, not in a power-saving state when installing or removing feature keys.  
In a power-saving state some components are powered down and cannot respond to feature key changes.  
Any Sheet page sizes  
When submitting a job where the media size is set to “ANY_SHEET” all standard page sizes will be used to identify  
a good fitting sheet. Standard page sizes include all ANSI, ARCH, ISO A, ISO B, 30x42, 17x25, 22x36 and  
extended ISO sizes like 297x1189, 297x841, 420x841, 594x1189, 841x2378.,  
Changing settings on Instant Accxes folders  
When settings are changed on Instant Accxes folders, the folder usually needs to be re-shared to the network.  
This may cause InstantAccxes folders which are open on client workstations to become invalid until the user  
closes the folder and re-opens it.  
Background removal is dependant on the document  
Background removal is a function of the document content and may be different depending on which side  
of the document is scanned first. Rotating a document which had poor background suppression results may  
improve the background removal.  
The toner door is interlocked  
There is an interlock switch on the toner door which will shut down the machine if the door is opened to  
prevent injury to users.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Windows 2008 security settings and TotalAccxes  
When using TotalAccxes on Windows 2008 servers, you must make some security setting changes to allow  
for the configuration of remote destinations. One of the following will work.  
Enable scripting.  
a. Go to Tools->Internet Options->Security  
b. Click on 'Custom level...' for the 'Internet' security zone.  
c. Scroll down until you reach the category 'Scripting' and set  
'Active Scripting' to enabled.  
Add the site to the trusted sites zone  
a. Navigate to the page you wish to allow to work  
b. Go to File->Add this site to->Trusted Sites Zone  
Disable the Internet Explorer Enhanced Security Configuration  
a. Open the Server Manager  
b. Click on 'Configure IE ESC'  
c. Turn off IE ESC for either Administrators or Users as seen fit.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Customer Issues Resolved  
The following issues were resolved in 13.0 build 141  
Issue Description  
Problem  
Resolution  
Wide Format Scan System was not Proper operation of the system  
properly enabled for system use  
One can now use the Synergix  
scanner on a 6279 with FreeFlow  
Accxes 13.0 build 141.  
was not attained.  
Could not properly build sets.  
Could not scan document that  
exited out the rear of the scanner.  
Power Cycles of the Wide Format  
Scan System would cause faults in  
FreeFlow Accxes  
Arch 15 not present throughout  
Web Printer Management Tool  
Several drop down menus in Web  
Printer Management Tool did not  
include the newly support Arch 15  
for 6279  
Web Printer Management Tool  
now includes Arch 15 where it was  
missing with FreeFlow Accxes 13.0  
build 141  
Running out of media caused  
FreeFlow Accxes faults  
A job submitted through FreeFlow  
Accxes Client Tools which  
exhausted media supplied causing  
a mismatch created FreeFlow  
Accxes faults  
With FreeFlow Accxes 13.0 build  
141 this will no longer occur.  
Multi Page document memory  
constraint messaging problematic  
When creating a multi-page  
The error message will now remain  
up for the user to acknowledge.  
document, if the space required to  
create a page is not present, an  
error was raised too quickly to read  
Cropping messages would cause  
workflow to be interrupted  
If a cropping message was raised,  
the scanner would not accept any  
more documents  
The error message no longer  
causes the workflow interruption  
using FreeFlow Accxes 13.0 build  
141.  
6279 Scan to Net key removal did  
not provide the Key Uninstall  
Verification code  
Remove the 6279 Scan to Net key. The Key Uninstall Verification  
After the reboot the Key Uninstall  
Verification Page was not printed.  
page is now printed after the  
removal of the 6279 Scan to Net  
key.  
The following issues were resolved in 13.0 build 133  
Issue Description  
Problem  
Resolution  
SPAR# 381119429, 966453196 –  
Cannot Print certain DWF files  
DWF file does not print any pages  
DWF interpreter upgraded and  
now prints these certain DWF files  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Page left blank intentionally  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Prepared by:  
Xerox Corporation  
800 Phillips Road  
Building 139-26A  
Webster, New York 14580-9791  
USA  
©XEROX Corporation. 2008. All rights reserved.  
XEROX®, the sphere of connectivity design, XEROX Wide Format 6279, 6204, 6030, 6050, 6050A, 510, 721, 8825, 8830, 8850,  
Xerox Wide Format Scan System, FreeFlow® Accxes®, and acronyms, are trademarks of Xerox Corporation in the United States  
and/or other countries.  
12/2008  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Weider Home Gym WEBE12622 User Manual
West Bend Back to Basics Blender Smoothie Professional User Manual
Windmere Mixer WMX5100C User Manual
Wolf Convection Oven 822077 User Manual
Wolfgang Puck Food Processor BFPR0007 User Manual
Wow Wee Robotics 8096 User Manual
Wright Manufacturing Lawn Mower 98210001 User Manual
X Micro Tech MP3 Player EVA 130 User Manual
Zadro Products Light Therapy Device SUN365 User Manual
Zanussi Washer ZWF 1210W User Manual