		 Drip Zone Valve Kit   
					Model 53749   
					Installation Instructions   
					Specifications   
					Kit Components   
					• Inlet/Outlet Pipe Connection: 3/4" Female NPT   
					• Maximum Supply Pressure: 150 PSI   
					• Downstream Pressure Regulation: 25 PSI   
					• Flow Rate @ 25 PSI: 0.25–8 GPM   
					• Filtration: 150 Count Stainless Mesh Screen   
					• Irrigation Control Valve:   
					• 3/4" (FPT X FPT) Ball Valve   
					• 3/4" (MPT X MPT) F Series Y-Filter, 150 Mesh   
					• 3/4" (FPT X FPT) Toro Jar Top Valve, Anti-Siphon (AVB)   
					• 3/4" NPT Close Nipple   
					• 3/4" (FPT X FPT) Pressure Regulator, 25 PSI at 0.25–8 GPM   
					• Automatic, Anti-Siphon, Toro Jar Top Model   
					• Manual Bleed and Flow Control   
					• 24 V a.c., 60 Hz Solenoid   
					Installation Procedure   
					CAUTION: When assembling the Drip Zone Valve   
					Kit components, use just 11⁄2 to 2 turns of Teflon   
					tape on male threads. Never use pipe dope.   
					To achieve a leak-free thread connection, turn the   
					male fitting until it is finger tight, then add one or   
					two more turns. Over-tightening can cause splitting   
					and failure of the female threads.   
					Bonnet Ring   
					Bonnet   
					Figure 1   
					Filter Screen   
					Important: Ensure the Y-Filter, Jar Top Valve and   
					Pressure Regulator are installed in the correct flow   
					orientation. Flow direction arrows are provided on each   
					component. Refer to Figure 1 and Figure 2.   
					Body   
					1. Using the Close Nipple, install the Ball Valve to the Jar   
					Top Valve inlet.   
					2. Remove the Bonnet Ring from the Y-Filter by turning   
					it counterclockwise. Remove the Bonnet and Filter   
					Screen. See Figure 1.   
					3. Install the Y-Filter inlet to the Jar Top Valve outlet.   
					4. Install the Pressure Regulator inlet to the Y-Filter outlet.   
					5. Reassemble the Y-Filter components.   
					Note: Valve must be   
					Figure 2   
					installed at least 6"   
					above the highest   
					emitter it controls.   
					Jar Top Valve   
					Note: Hand tighten the Bonnet Ring only – do not   
					over-tighten.   
					Close Nipple   
					Ball Valve   
					Important: Refer to the provided Toro Jar Top Valve,   
					Anti-Siphon (AVB) installation instructions for additional   
					important installation and operating information.   
					Y-Filter   
					6. To determine the recommended minimum/maximum   
					number of drip emitters per Jar Top valve, refer to the   
					table below.   
					Pressure   
					Regulator   
					From Water   
					Supply   
					To Emitters   
					For technical assistance, call 1-800-367-8676.   
					ꢀ 
					© 2005 The Toro Company, Consumer Division • An ISO 9000-certified Company   
					
					Form Number 373-0347 Rev. B   
					RELEASED Version ©Toro 2005-2005   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |