Table of Contents
Making a Technical Support Query ...................................................... 14
Repair Procedure.................................................................................... 15
Feedback on this Manual....................................................................... 15
Command Syntax ................................................................................... 17
Command Shortcuts .............................................................................. 18
Command Options ................................................................................. 18
Set Console............................................................................................. 19
Set Custom-App ..................................................................................... 19
Set Port-Buffering................................................................................... 20
Set Server................................................................................................ 21
Set SSL Server........................................................................................ 24
Set Service .............................................................................................. 25
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Console .........................................................................................26
Show Server ............................................................................................26
Show Port-Buffering...............................................................................26
Show Modbus..........................................................................................27
Set Ethernet.............................................................................................27
Show Hardware.......................................................................................27
Set SSH-Server........................................................................................27
Show SSH-Server....................................................................................28
Set SSL Server ........................................................................................29
Show SSL ................................................................................................31
Show Modbus..........................................................................................32
Set Authentication ..................................................................................33
Set Authentication NIS ...........................................................................35
Add RADIUS ............................................................................................35
Delete RADIUS ........................................................................................35
Show Authentication ..............................................................................38
4
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Show TruePort........................................................................................ 38
Set Email-Alert Server............................................................................ 39
Show Email-Alert Server........................................................................ 39
Add Clustering Slave-IP......................................................................... 40
Set Clustering Slave-IP .......................................................................... 41
Show Clustering Slave-IP ...................................................................... 41
Set Dynamic-DNS ................................................................................... 42
Set Dynamic-DNS SSL ........................................................................... 42
Set Dynamic-DNS SSL Cipher-Suite..................................................... 44
Show Dynamic-DNS ............................................................................... 45
Set PCI Card............................................................................................ 45
Show PCI................................................................................................. 45
Set PCI Wireless-WAN ........................................................................... 46
Show Wireless-WAN .............................................................................. 46
Set IPv6.................................................................................................... 47
Show IPv6................................................................................................ 47
Add Custom-IPv6.................................................................................... 48
Set Custom-IPv6..................................................................................... 49
Delete Custom-IPv6................................................................................ 49
Set IPv6-Router-Advertisement............................................................. 50
Show IPv6-Router-Advertisement......................................................... 50
Admin ...................................................................................................... 51
Help.......................................................................................................... 51
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Kill Line....................................................................................................51
Kill Session..............................................................................................51
Logout......................................................................................................51
Menu.........................................................................................................52
Ping ..........................................................................................................52
Resume....................................................................................................52
Rlogin.......................................................................................................52
Screen......................................................................................................52
Set Termtype ...........................................................................................53
Set User ...................................................................................................53
Set User Session.....................................................................................54
Show Line Users.....................................................................................55
SSH...........................................................................................................55
Syslog Console.......................................................................................56
Show Sessions........................................................................................56
Show Termtype .......................................................................................56
Start..........................................................................................................56
Telnet .......................................................................................................57
Version.....................................................................................................58
Add User..................................................................................................58
Delete User ..............................................................................................58
Set Default User ......................................................................................59
Set User ...................................................................................................62
Set User Session.....................................................................................66
Show Default User ..................................................................................66
Show User ...............................................................................................66
Set Line....................................................................................................67
Set Line Interface....................................................................................72
Set Line Service ......................................................................................73
Set Modem...............................................................................................76
6
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Termtype........................................................................................... 76
Show Line................................................................................................ 77
Set Custom-App ..................................................................................... 78
Set Rlogin-Client..................................................................................... 78
Set Telnet-Client ..................................................................................... 78
Set SSH-Client ........................................................................................ 79
Set PPP.................................................................................................... 81
Set SLIP................................................................................................... 85
Set UDP ................................................................................................... 86
Set Vmodem............................................................................................ 87
Set Vmodem-Phone................................................................................ 90
Set SSL Line............................................................................................ 90
Set SSL Line Cipher-suite...................................................................... 92
Set Modbus-Slave Line .......................................................................... 93
Set Power-Management Line................................................................. 94
Set Multihost Line................................................................................... 95
Show Custom-App ................................................................................. 95
Show Interface........................................................................................ 95
Show PPP................................................................................................ 96
Show Rlogin-Client................................................................................. 96
Show SLIP............................................................................................... 96
Show SSH-Client .................................................................................... 96
Show Telnet-Client ................................................................................. 96
Show Modbus ......................................................................................... 96
Show UDP ............................................................................................... 96
Show Vmodem........................................................................................ 96
Show Vmodem-Phone............................................................................ 96
Add Modem............................................................................................. 97
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Delete Modem..........................................................................................97
Set Modem...............................................................................................97
Show Modems.........................................................................................97
Set Email-Alert Line................................................................................98
Add Community ....................................................................................103
Add Trap ................................................................................................103
Delete Community ................................................................................104
Delete Trap ............................................................................................104
Set SNMP...............................................................................................104
Show SNMP...........................................................................................106
Set Server TFTP ....................................................................................106
Add Host................................................................................................106
Delete Host ............................................................................................106
Set Host .................................................................................................107
Show Hosts ...........................................................................................107
Add DNS ................................................................................................107
Add WINS...............................................................................................107
Delete DNS.............................................................................................108
Delete WINS...........................................................................................108
Show DNS..............................................................................................108
8
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Show Server.......................................................................................... 108
Show WINS............................................................................................ 108
Add Gateway......................................................................................... 109
Delete Gateway..................................................................................... 110
Set Gateway .......................................................................................... 110
Show Gateways .................................................................................... 110
Set Syslog ............................................................................................. 111
Show Syslog ......................................................................................... 111
Add RIP.................................................................................................. 112
Delete RIP.............................................................................................. 112
Set RIP................................................................................................... 113
Show RIP............................................................................................... 113
Show RIP Peers .................................................................................... 114
Add IPsec .............................................................................................. 114
Set IPsec................................................................................................ 114
Show IPsec............................................................................................ 117
IPsec ...................................................................................................... 117
Add IPv6tunnel ..................................................................................... 117
Set IPv6tunnel....................................................................................... 118
Show IPv6tunnel................................................................................... 118
Delete IPv6tunnel.................................................................................. 118
Set L2TP ................................................................................................ 119
Show LT2P ............................................................................................ 121
Set VPN Exception ............................................................................... 121
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Time.................................................................................................123
Set Timezone.........................................................................................123
Show Time.............................................................................................123
Show Timezone.....................................................................................123
Add SNTP ..............................................................................................124
Delete SNTP...........................................................................................124
Set SNTP................................................................................................124
Show SNTP............................................................................................125
Show SNTP-Info....................................................................................125
Set Date..................................................................................................125
Set Summertime....................................................................................125
Show Date..............................................................................................127
Reboot....................................................................................................129
Reset ......................................................................................................129
Reset Factory ........................................................................................129
Save........................................................................................................129
Set Bootup.............................................................................................130
Show ARP..............................................................................................130
Show Bootup.........................................................................................130
10
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Netload .................................................................................................. 130
Netsave.................................................................................................. 131
Netload .................................................................................................. 132
Set.......................................................................................................... 132
Netload .................................................................................................. 133
Netsave.................................................................................................. 134
Set MOTD .............................................................................................. 135
Show MOTD .......................................................................................... 135
Show Netstat......................................................................................... 137
Show Netstat Statistics........................................................................ 137
Show Modbus Statistics ...................................................................... 138
Show Routes......................................................................................... 138
Delete Arp.............................................................................................. 138
Show Arp............................................................................................... 138
Show Serial ........................................................................................... 138
Uptime ................................................................................................... 138
Set IO UDP............................................................................................. 141
Set IO Failsafe....................................................................................... 142
Set IO Modbus ...................................................................................... 142
Set IO Temperature-Scale.................................................................... 142
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Line Service ....................................................................................142
Kill IOChannel .......................................................................................155
Show IO..................................................................................................156
Show IOChannel ...................................................................................156
Digital Output ........................................................................................156
Digital Input ...........................................................................................157
Relay ......................................................................................................157
Analog Input..........................................................................................157
Calibrate Analog ...................................................................................157
Reset Calibration ..................................................................................157
12
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
About This Book
This guide provides the information you need to:
configure the IOLAN using the Command Line Interface (CLI)
z
Intended Audience
This guide is for administrators who will be configuring the IOLAN.
Some prerequisite knowledge is needed to understand the concepts and examples in this guide:
z
z
If you are using an external authentication application(s), working knowledge of the
authentication application(s).
Knowledge of TFTP, the transfer protocol the IOLAN uses.
Typeface Conventions
Most text is presented in the typeface used in this paragraph. Other typefaces are used to help you
identify certain types of information. The other typefaces are:
Typeface Example
Usage
At the C: prompt, type:
add host
This typeface is used for code examples and
system-generated output. It can represent a line you type
in, or a piece of your code, or an example of output.
Set the value to TRUE.
The typeface used for TRUEis also used when referring to
an actual value or identifier that you should use or that is
used in a code example.
subscribe project subject
The italicized portion of these examples shows the
typeface used for variables that are placeholders for
values you specify. This is found in regular text and in
code examples as shown. Instead of entering project,
you enter your own value, such as stock_trader, and
for yourcode, enter the name of your program.
run yourcode.exec
IOLAN User’s Guide
This typeface indicates a book or document title.
more information.
This indicates a cross-reference to another chapter or
section that you can click on to jump to that section.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Contacting Technical Support
Contacting Technical Support
Making a Technical Support Query
Who To Contact
Note:
Perle offers free technical support to Perle Authorised Distributors and Registered Perle
Resellers.
If you bought your product from a registered Perle supplier, you must contact their Technical Support
department; they are qualified to deal with your problem.
Have Your Product Information Ready
When you make a technical support enquiry please have the following information ready:
Item
Write Details Here
Product Name
Problem Description
Your Name
Company Name and
Address
Country
Phone Number
Fax Number
Email Address
Making a support query via the Perle web page
If you have an internet connection, please send details of your problem to Technical Support using
the email links provided on the Perle web site in the Support/Services area.
14
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Contacting Technical Support
Repair Procedure
Before sending a IOLAN for repair, you must contact your Perle supplier. If, however, you bought
your product directly from Perle you can contact directly.
Customers who are in Europe, Africa or Middle East can submit repair details via a website form.
This form is on the Perle website, www.perle.com, in the Support/Services area.
Feedback on this Manual
If you have any comments or suggestions for improving this manual please email Perle using the
following address:
Please include the title, part number and date of the manual (you can find these on the title page at
the front of this manual).
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Contacting Technical Support
16
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Chapter
1
1
This book provides the command line interface (CLI) options available for the IOLAN. The
commands are grouped by function.
CLI Conventions
This section explains how to interpret the CLI syntax. If you are an existing IOLAN+ customer and
would like to configure the IOLAN in the native IOLAN+ interface, you can type the command
iolan+to display and use the native IOLAN+ interface (you must have User Level Admin). See
your IOLAN+ User Guide for information on using the IOLAN+ interface.
Command Syntax
Each command is broken down into several categories:
z
z
Description—Provides a brief explanation of how the command is used.
User Level—Shows which user level(s) (Restricted, Normal, and/or Admin) can issue the
command. Some commands have options that are available for one user level and not for another
level; this usually occurs when a command is valid for both Normal and Admin user levels,
where the Admin user level command will have extended options.
z
Syntax—Shows the actual command line options. The options can be typed in any order on the
command line. The syntax explanation will use the following command to break down the
command syntax:
set service [dhcp/bootp on|off] [telnetd on|off] [httpd on|off]
[snmpd on|off] [spcd on|off] [syslog on|off] [dmgrd on|off]
–
–
Square brackets ([]) show the options that are available for the command. You can type a
command with each option individually, or string options together in any order you want.
For example,
set service dhcp/bootp on telnetd off
Angle brackets (<>) show that the text inside the brackets is a description for a variable
value that you must fill in according to your requirements. In the set servercommand,
you must determine the values for domain, internet, name, password-limit, and
subnet-bit-length, if you wish to specify them and not use their defaults (default values
provided in the Options description). The angle brackets can also contain a range that can be
used.
–
The pipe (|) shows an ’or’ condition. For example, valid values for telnetdare either onor
off.
z
Options—Provides an explanation of each of the options for a command and the default value if
there is one. Some commands do not have any options, so this category is absent.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
17
Download from Www.Somanuals.com. All Manuals Search And Download.
CLI Conventions
Command Shortcuts
When you type a command, you can specify the shortest unique version of that command or you can
press the ESC or TAB key to complete the command. For example, the following command:
set telnet-client map-to-crlf off
can be typed as:
set tel map off
or, you can use the ESC key to complete the lines as you go along:
set tel<ESC>net-client ma<ESC>p-to-crlf off
where the ESC key was pressed to complete the option as it was typed.
Command Options
When you are typing commands on the command line (while connected to the IOLAN), you can view
the options by typing a question mark (?), ESC, or TAB key after any part of the command to see
what options are available/valid. For example:
DS$ set vmodem ?
failure-string
host
port
style
success-string
suppress
DS$ set vmodem failure-string ?
<text>
30 characters maximum
DS$ set vmodem failure-string "Vmodem failed" ?
failure-string
host
port
style
success-string
suppress
Or press Enter to confirm command
DS$ set vmodem failure-string "Vmodem failed"
DS$ show vmodem
Host
Host Port
Success String
Failure String
Suppress
Style
"Vmodem failed"
Off
Numeric
DS$
18
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
Chapter
2
2
This chapter defines all the CLI commands associated with configuring the IOLAN server
parameters.
Server Commands
Set Console
Description Sets the flow control and baud rate on IOLAN models that have a dedicated console
port.
User Level Admin
set console [flow none|soft|hard]
[speed 9600|19200|38400|57600|115200]
Syntax
Options
flow
For IOLAN models that have a dedicated console port, defines whether the data flow is
handled by using software (Soft), hardware (Hard), or no (None) flow control.
speed
For IOLAN models that have a dedicated console port, specifies the baud rate of the
line connected to the console port.
Set Custom-App
Description You can create a custom application that can run on the IOLAN using the Perle SDK.
User Level Admin
set custom-app server program-command-line <command>
Syntax
Options
program-command-line
The name of the SDK program executable that has been already been downloaded to
the IOLAN, plus any parameters you want to pass to the program. Maximum of 80
characters. Use the shellCLI command as described in the SDK Programmer’s Guide
to manage the files that you have downloaded to the IOLAN. For example, using
sample outrawprogram, you would type:
outraw -s 0 192.168.2.1:10001 Acct:10001
if you were starting the application on the Server (notice the -s 0parameter specifies
Line 1).
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
Set Port-Buffering
Description Configures port buffering.
User Level Admin
set port-buffering [duplicate-nfs-to-syslog on|off]
Syntax
[keys-stroke-buffering on|off] [mode off|local|remote|both]
[nfs-directory <text>] [nfs-encryption on|off]
[nfs-host <config_host>] [time-stamp on|off]
[view-port-buffer-string <text>]
Options
duplicate-nfs-to-syslog
When enabled, buffered data is sent to the syslog host to be viewed on the host’s
monitor. The default is off.
key-stroke-buffering
When enabled, key strokes that are sent from the network host to the serial device on
the IOLAN’s serial port are buffered. The default is off.
mode
Specifies where the port buffer log is kept, either Off, Local, Remote, or Both. If
Remote or Both is selected, you must specify an NFS server location for the port buffer
log.
nfs-directory
The directory and/or subdirectories where the Remote Port Buffering files will be
created. This field is used when Port Buffering Mode is set to Remote or Both. For
multiple IOLANs using the same NFS host, it is recommended that each IOLAN have
its own unique directory to house the remote port log files. The default is
/device_server/portlogs.
nfs-encryption
Determines if the data sent to the NFS host is sent encrypted or in the clear across the
LAN. The default is set of Off.
NOTE: When NFS encryption is enabled, the Decoder utility software is required to be
installed on the NFS host for decrypting the data to a readable format. The Decoder
utility software can be found on the installation CD-ROM and on the www.perle.com
website.
nfs-host
The NFS host that the IOLAN will use for its Remote Port Buffering feature. The
IOLAN will open a file on the NFS host for each reverse SSH or reverse Telnet line,
and send any port data to be written to those files. The default is None. This field is
required when Mode is set to Remote or Both.
time-stamp
Enable/disable time stamping of the port buffer data.
view-port-buffer-string
The string (up to 8 characters) used by a a session connected to a serial port to display
the port buffer for that particular serial port. You can specify control (unprintable) codes
by putting the decimal value in angle brackets < > (for example, Escape b is <027>b).
The default is ~view.
20
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
Set Server
Description Sets server parameters.
User Level Admin
set server [auto-obtain-dns on|off] [auto-obtain-gw on|off]
[auto-obtain-wins on|off] [banner on|off] [break on|off]
Syntax
[bypass-password on|off] [dhcp-update-dns on|off]
[domain <string>] [flush-on-close on|off]
[line-menu-string <string>] [monitor-connection-every <1-32767>]
[name <string>] [netmask <IPV4_address>] [oem-login on|off]
[password-limit <0-10>] [prompt-with-name on|off]
[ip-filter on|off] [session-escape-string <string>]
[single-telnet on|off] [monitor-connection-every <seconds>]
[active-standby on|off] [miimon <milliseconds>]
[updelay <milliseconds>] [power-management-menu-string <string>]
set server internet [eth1|eth2] <IPV4_address> [netmask]
set server internet [eth1|eth2] dhcp/bootp on dhcp-update-dns on
domain-prefix <text>
set server internet [eth1|eth2] dhcp/bootp on dhcp-update-dns off
set server internet [eth1|eth2] dhcp/bootp off <IPV4_address>
[<netmask>]
set server tftp [retry <integer>] [timeout <integer>]
set server ssl-passphrase
Options
auto-obtain-dns
When DHCP/BOOTP is enabled, you can enable this option to have the IOLAN receive
the DNS IP address from the DHCP/BOOTP server.
auto-obtain-gw
When DHCP/BOOTP is enabled, you can enable this option to have the IOLAN receive
the Default Gateway IP address from the DHCP/BOOTP server.
auto-obtain-wins
When DHCP/BOOTP is enabled, you can enable this option to have the IOLAN receive
the WINS IP address from the DHCP/BOOTP server.
banner
This parameter concerns the banner information (product name/software version). This
banner information is presented to a user with a login prompt. For security reasons, you
can turn off the display of this information. The default is Off.
break
Enables/disables proprietary inband SSH break signal processing as well as the existing
Reverse Telnet break signal. This parameter can also enable/disable the out-of-band
break signals for TruePort. The default value is Off.
bypass-password
When set, authorised users who do not have a password set, with the exception of the
Admin user, WILL NOT be prompted for a password at login with Local
Authentication.
Server Commands 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
dhcp-update-dns
The DHCP server will update the DNS server when the IOLAN requests a DHCP IP
address (the communication between the DNS server and the DHCP server must
already be set up in your network).
dhcp/bootp
Enables the DHCP/BOOTP client process in the IOLAN. By default, this is
disabled/off. If this is enabled, the server IP address parameter is disabled.
domain
Unique name for your domain, your location in the global network. Like Hostname, it is
a symbolic, rather than a numerical, identifier.
domain-prefix
(SCS models only) A domain prefix to uniquely identify the Ethernet interface to the
DNS when the IOLAN has two Ethernet interfaces. The format of the Ethernet interface
will take the form of <Server Name>.<Domain Prefix>.<Domain Name> or <Server
Name>.<Domain Prefix>, depending on what is configured.
flush-on-close
When enabled, deletes any pending outbound data when a port is closed; as opposed to
maintaining the port to send pending data. The default value is Off.
internet
The IOLAN’s unique IPv4 network IP address. If you are using the IOLAN in an IPv6
network, use the set ipv6 command.
internet [eth1|eth2]
Dual Ethernet SCS models require that you specify which Ethernet connection you are
setting, either eth1 or eth2.
name
You must supply a name for the IOLAN.
netmask
The network subnet mask. For example, 255.255.0.0.
line-menu-string
The string used to access to the Easy Port Access menu without disconnecting the initial
reverse SSH or reverse Telnet session.The default string is ~menu.
monitor-connection-every
Specify how often, in seconds, the IOLAN will send a TCP keepalive. This only applies
to line service types that support the keepalive feature. The default interval is every 30
seconds
oem-login
When set, and a custom language file is in use, the login prompt will use the string
defined in the language file as the login prompt instead of the default prompt, login:.
22
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
password-limit
The number of attempts a user is allowed to enter a password for a serial port
connection from the network, before the connection is terminated and the user has to
attempt to login again. For users logging into the serial port, if this limit is exceeded,
the serial port is disabled for 5 minutes. A user with Admin level rights can restart the
serial port, bypassing the timeout, by issuing a kill on the disabled serial port. The
default value is 3.
prompt-with-name
Displays the Server Name field value instead of default product name. When enabled,
the Server Name is displayed in the IOLAN login prompt, CLI prompt, WebManager
login screen, and the heading of the Menu. The default value is Off.
ip-filter
A security feature that when enabled, the IOLAN will only accept data from hosts
configured in the IOLAN’s Host Table with an IP address (hosts configured with a
Fully Qualified Domain Name, FQDN, will not be able to access the IOLAN when this
option is enabled). The default value is Off.
single-telnet
Sets all reverse connections (raw, SSH, and telnet) to a one connection at a time mode.
In this mode of operation, the IOLAN will only allow for a single TCP connection at a
time to exist for each serial port configured for a reverse connection type. Subsequent
connection attempts will be refused until all of the following conditions are met:
z
No active connection to serial port exists and at least 1 second has passed since the
last connection was terminated.
z
All data from the previous connection on the serial port has been transmitted.
The IOLAN has logic to automatically detect when a reverse connection is no longer
active. When this happens, the connection is reset and the server can go back to a
listening for an incoming connection state.
Applications using Single Telnet need to be aware that there can be some considerable
delay between a network disconnection and the port being available for the next
connection attempt; this is to allow any data sent on prior connections to be transmitted
out of the serial port. Application network retry logic needs to accommodate this
feature. The default value is Off.
active-standby
(SCS only) Enables/disables the feature of automatically assigning the Ethernet 1 IP
address to Ethernet 2 if Ethernet 1 should fail to communicate to the network.
miimon
(SCS only) The interval in which the active interface is checked to see if it is still
communicating. The default is 100 ms.
updelay
(SCS only) The time that the IOLAN will wait to make the secondary interface
(Ethernet 2) active after it has been detected as up.
power-management-menu-string
Users accessing the IOLAN through reverse sessions can enter the string to bring up a
power bar management menu. This string can be up to 8 characters. Control characters
can be specified by putting their decimal value within angled brackets. The default
value is <016> or Ctrl-p on the keyboard.
Server Commands 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
session-escape-string
A configurable string that allows access to a port to view the multisession screen
options, allowing the various options while accessing the particular port on the
IOLAN. You can specify control (unprintable) codes by putting the decimal value in
angle brackets < > (for example, ESC-b is <027>b). The default value is Ctrl-z s
(<026>s in decimal).
retry
The number of times the IOLAN will retry to transmit a TPFT packet to/from a host
when no response is received. Enter a value between 0 and 5. The default is 5. A value
of 0 (zero) means that the IOLAN will not attempt a retry should TFTP fail.
timeout
The time, in seconds, that the IOLAN will wait for a successful transmit or receipt of
TFTP packets before retrying a TFTP transfer. Enter a value between 3 and 10. The
default is 3 seconds.
ssl-passphrase
This is the SSL/TLS passphrase used to generate an encrypted RSA/DSA private key.
This private key and passphrase are required for both HTTPS and SSL/TLS
connections, unless an unencrpyted private key was generated, then the SSL passphrase
is not required. Make sure that you download the SSL private key and certificate if you
are using the secure HTTP option (HTTPS) or SSL/TLS. If both RSA and DSA private
keys are downloaded to the IOLAN, they need to be generated using the same SSL
passphrase for both to work.
Set SSL Server
Description Sets the default SSL/TLS parameters for the server.
User Level Admin
set ssl server [version any|tslv1|sslv3] [type client|server]
[verify-peer on|off]
Syntax
[validation-criteria
country <code>|state-province <text>|locality <text>
|organisation <text>|organisation-unit <text>
|common-name <text>|email <email_addr>]
Options
version
Specify whether you want to use:
z
Any—The IOLAN will try a TLSv1 connection first. If that fails, it will try an
SSLv3 connection. If that fails, it will try an SSLv2 connection.
z
z
TLSv1—The connection will use only TLSv1.
SSLv3—The connection will use only SSLv3.
The default is Any.
type
Specify whether the IOLAN will act as an SSL/TLS client or server. The default is
Client.
verify-peer
Enable this option when you want the Validation Criteria to match the Peer Certificate
for authentication to pass. If you enable this option, you need to download an SSL/TLS
certificate authority (CA) list file to the IOLAN.
24
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
validation-criteria
Any values that are entered in the validation criteria must match the peer certificate for
an SSL connection; any fields left blank will not be validated against the peer
certificate.
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the peer SSL/TLS certificate.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the peer SSL/TLS
certificate.
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the peer SSL/TLS certificate.
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
Set Service
Description Sets server service parameters.
User Level Admin
set service [routed on|off] [telnetd on|off] [sshd on|off]
Syntax
[httpd on|off] [snmpd on|off] [spcd on|off] [sntp on|off]
[httpsd on|off] [syslog on|off] [dmgrd on|off] [modbusd on|off]
[ipsec on|off]
Options
routed
Route daemon process in the IOLAN on port 520.
telnetd
Telnet daemon process in the IOLAN on port 23.
sshd
SSH daemon process in the IOLAN on port 22.
Server Commands 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Server Commands
httpd
HTTP daemon process in the IOLAN on port 80.
snmpd
SNMP daemon process in the IOLAN on port 161.
spcd
SPC (TruePort) daemon process in the IOLAN that supports TruePort Full Mode on
UDP port 668. You can still communicate with the IOLAN in Lite Mode when this
service is disabled.
sntp
Simple Network Time Protocol client process in the IOLAN.
httpsd
Secure HTTP daemon process in the IOLAN on port 443.
syslog
Syslog client process in the IOLAN.
dmgrd
DeviceManager daemon process in the IOLAN. If you disable this service, you will not
be able to connect to the IOLAN with the DeviceManager application.
DeviceManagerD listens on port 33812 and sends on port 33813.
modbusd
Modbus daemon process in the IOLAN on port 502.
ipsec
IPsec daemon process in the IOLAN listening and sending on UDP port 500. This is
disabled by default.
Show Console
Description For IOLAN models that have a dedicated console port, this command displays the
configured parameters of the console port.
User Level Admin
show console
Syntax
Show Custom-App
Description Shows the custom application server settings.
User Level Admin
show custom-app server
Syntax
Show Server
Description Shows the parameters set for the server.
User Level Admin, Normal
show server
Syntax
Show Port-Buffering
Description Shows the port buffering settings.
User Level Normal, Admin
show port-buffering
Syntax
26
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Commands
Show Modbus
Description Shows the Modbus settings for the gateway.
User Level Normal, Admin
show modbus gateway
Syntax
Hardware Commands
Set Ethernet
Description Sets the hardware configuration for the Ethernet port(s).
User Level Admin
set ethernet [eth1|eth2] speed-and-duplex
auto|10-half|10-full|100-half|100-full|1000-full
Syntax
Options
eth1|eth2
You must specify the Ethernet interface if you have an SCS model with dual Ethernet.
auto|10-half|10-full|100-half|100-full|1000-full
Define the Ethernet connection speed at one of the following (desktop models don’t
support 1000 Mbps):
z
auto—automatically detects the Ethernet interface speed and duplex
z
z
z
z
z
10 Mbps Half Duplex
10 Mbps Full Duplex
100 Mbps Half Duplex
100 Mbps Full Duplex
1000 Mbps Full Duplex
Show Hardware
Description Shows the hardware resources, Ethernet link status, date and time.
User Level Normal, Admin
show hardware
Syntax
SSH Server Commands
Set SSH-Server
See Keys and Certificates in the IOLAN User’s Guide for information about the keys and certificates
that need to be uploaded or downloaded with the IOLANs SSH server.
Description Configures the IOLANs SSH server.
User Level Admin
set ssh-server [authentication rsa on|off]
[authentication dsa on|off] [authentication password on|off]
[authentication keyboard-interactive on|off]
[break-string <text>] [compression on|off] [ssh1 on|off]
[verbose on|off]
Syntax
set ssh-server cipher [3des on|off] [blowfish on|off]
[cast on|off] [aes on|off] [arcfour on|off]
Options
authentication rsa
An authentication method used by SSH version 1 and 2. Use RSA authentication for the
SSH session.
Server Commands 27
Download from Www.Somanuals.com. All Manuals Search And Download.
SSH Server Commands
authentication dsa
An authentication method used by SSH version 2. Use DSA authentication for the SSH
session.
authentication password
The user types in a password for authentication.
authentication keyboard-interactive
The user types in a password for authentication.Used for SSH2 only.
compression
Requests compression of all data. Compression is desirable on modem lines and other
slow connections, but will only slow down things on fast networks.
verbose
Displays debug messages on the terminal.
break-string
The break string used for inband SSH break signal processing. A break signal is
generated on a specific serial port only when the server's break option is enabled and
the user currently connected using reverse SSH has typed the break string exactly. The
default is set to ~break, where ~ is tilde; the break string can be up to eight characters.
ssh1
Allows the user’s client to negotiate an SSH-1 connection, in addition to SSH-2.
cipher
Specify which ciphers the IOLAN’s SSH server can use to negotiate data encryption
with an SSH client session.
Show SSH-Server
Description Shows the SSH server settings.
User Level Admin
show ssh-server
Syntax
28
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
SSL/TLS Commands
SSL/TLS Commands
Set SSL Server
Description Sets the default SSL/TLS parameters for the server.
User Level Admin
set ssl server [version any|tslv1|sslv3] [type client|server]
[verify-peer on|off]
Syntax
[validation-criteria
country <code>|state-province <text>|locality <text>
|organisation <text>|organisation-unit <text>
|common-name <text>|email <email_addr>]
Options
version
Specify whether you want to use:
z
Any—The IOLAN will try a TLSv1 connection first. If that fails, it will try an
SSLv3 connection. If that fails, it will try an SSLv2 connection.
z
z
TLSv1—The connection will use only TLSv1.
SSLv3—The connection will use only SSLv3.
The default is Any.
type
Specify whether the IOLAN will act as an SSL/TLS client or server. The default is
Client.
verify-peer
Enable this option when you want the Validation Criteria to match the Peer Certificate
for authentication to pass. If you enable this option, you need to download an SSL/TLS
certificate authority (CA) list file to the IOLAN.
validation-criteria
Any values that are entered in the validation criteria must match the peer certificate for
an SSL connection; any fields left blank will not be validated against the peer
certificate.
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the peer SSL/TLS certificate.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the peer SSL/TLS
certificate.
Server Commands 29
Download from Www.Somanuals.com. All Manuals Search And Download.
SSL/TLS Commands
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the peer SSL/TLS certificate.
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
Set SSL Server Cipher-suite
Description Sets the default SSL/TLS cipher suite parameters.
User Level Admin
set ssl server cipher-suite
Syntax
option1|option2|option3|option4|option5
encryption any|aes|3des|des|arcfour|arctwo|none
min-key-size 40|56|64|128|168|256
max-key-size 40|56|64|128|168|256
key-exchange any|rsa|edh-rsa|edh-dss|adh
hmac any|sha1|md5
Options
option1|option2|option3|option4|option5
Sets the priority of the cipher suite, with option1being highest priority and option5
lowest priority.
encryption
Select the type of encryption that will be used for the SSL connection:
z
z
z
z
z
z
z
Any—Will use the first encryption format that can be negotiated.
AES
3DES
DES
ARCFOUR
ARCTWO
None—Removes any values defined for the cipher option.
The default value is Any.
min-key-size
The minimum key size value that will be used for the specified encryption type. The
default is 40.
max-key-size
The maximum key size value that will be used for the specified encryption type. The
default is 256.
30
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Modbus Commands
key-exchange
The type of key to exchange for the encryption format:
z
Any—Any key exchange that is valid is used (this does not, however, include ADH
keys).
z
z
z
z
RSA—This is an RSA key exchange using an RSA key and certificate.
EDH-RSA—This is an EDH key exchange using an RSA key and certificate.
EDH-DSS—This is an EDH key exchange using a DSA key and certificate.
ADH—This is an anonymous key exchange which does not require a private key
or certificate. Choose this key if you do not want to authenticate the peer device,
but you want the data encrypted on the SSL/TLS connection.
The default is Any.
hmac
Select the key-hashing for message authentication method for your encryption type:
z
z
z
Any
MD5
SHA1
The default is Any.
Show SSL
Description Shows the SSL/TLS settings/information.
User Level Normal, Admin
show ssl
Syntax
Modbus Commands
Set Modbus Gateway
Description Sets the Modbus parameters for the IOLAN when it is operating as a Modbus Gateway.
User Level Admin
set modbus gateway [addr-mode embedded|re-mapped]
Syntax
[broadcast on|off] [char-timeout <number>]
[req-next-delay <number>] [exceptions on|off]
[idle-timer <number>] [mess-timeout <number>]
[port <TCP/UDP_port>] [req-queuing on|off]
[remapped-id <1-247>] [ssl on|off]
Options
addr-mode
Determines if the original UID address will be embedded in the transmission header or
if a specified (remapped) UID will be embedded in the transmission header.
broadcast
When enabled, a UID of 0 (zero) indicates that the message will be broadcast to all
Modbus Slaves. The default is Off.
char-timeout
Used in conjunction with the Modbus RTU protocol, specifies how long to wait, in
milliseconds, after a character to determine the end of frame. The default is 30 ms.
Server Commands 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Modbus Commands
req-next-delay
A delay, in milliseconds, to allow serial slave(s) to re-enable receivers before issuing
next Modbus Master request. The default is 50 ms.
exceptions
When enabled, an exception message is generated and sent to the initiating Modbus
device when any of the following conditions are encountered: there is an invalid UID,
the UID is not configured in the Gateway, there is no free network connection, there is
an invalid message, or the target device is not answering the connection attempt. The
default is On.
idle-timer
Specifies the number of seconds that must elapse without any network or serial traffic
before a connection is dropped. If this parameter is set to 0 (zero), a connection will not
be dropped (with the following exceptions: the TCP KeepAlive causes the connection
to be dropped or the Modbus device drops the connection). The default is 10 seconds.
mess-timeout
Time to wait, in milliseconds, for a response message from a Modbus TCP or serial
slave (depending if the Modbus Gateway is a Master Gateway or Slave Gateway,
respectively) before sending a Modbus exception. The default is 1000 ms.
port
The network port number that the Slave Gateway will listen on for both TCP and UDP
messages. The default is 502.
req-queuing
When enabled, allows multiple, simultaneous messages to be queued and processed in
order of reception. The default is On.
remapped-id
Specify the UID that will be inserted into the message header for the Slave Modbus
serial device. Valid values are 1-247.
ssl
When enabled, messages over the TCP connection are encrypted vis SSL/TLS.
Show Modbus
Description Displays the Modbus Gateway parameters.
User Level Admin
show modbus gateway
Syntax
show modbus slave|master <line_number>
32
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Authentication Commands
Authentication Commands
Set Authentication
Description Sets the authentication method for the IOLAN.
User Level Admin
set authentication type primary|secondary
none|local|radius|kerberos|ldap|tacacs+|securid|nis
Syntax
[secondary-as-backup on|off] [auth-admin-user-local on|off]
Options
primary
The first authentication method that the IOLAN attempts. Some type of authentication
must be done by the IOLAN, therefore, None is not a valid option for the Primary
Authentication Method.
secondary
If the Primary Authentication Method fails, the next authentication method that the
IOLAN attempts. You can choose to use authentication methods in combination. For
example, you can specify the Primary Authentication Method as Local and the
Secondary Authentication Method as RADIUS. Therefore, some users can be defined
in the IOLAN (Local) others in RADIUS.
none|local|radius|kerberos|ldap|tacacs+|securid|nis
Specify the authentication method that the IOLAN will use to authenticate users (this
must already be set up in your network).
secondary-as-backup
When enabled, the Secondary Authentication method will be tried only when the
IOLAN cannot communicate with the Primary Authentication server.
auth-admin-user-local
When enabled, the IOLAN will only authenticate the admin user in the local user
database, regardless of any external authentication methods configured. When disabled,
a user called admin must exist when only external authentication methods are
configured, or you will not be able to access the IOLAN as the admin user, except
through the console port. The default is on.
Set Authentication Local
Description Configures local authentication settings. When you configure the IOLAN to
authenticate users locally, you can require that the users be configured in the User table.
You can also enable the Guest mode. This mode allows users to log into the IOLAN
using any user name, but they will only get authenticated if they match the password
configured for the Guest account.
User Level Admin
set authentication local [guest-mode on|off] [password <text>]
Syntax
Options
guest-mode
Allow users who are not defined in the User database to log into the IOLAN with any
user ID and the specified password. Guest users inherit their settings from the Default
User’s configuration.
password
The password that Guest users must use to log into the IOLAN.
Server Commands 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Authentication Commands
Set Authentication Kerberos
Description Configures Kerberos authentication settings.
User Level Admin
set authentication kerberos [kdc-domain <string>]
[port <TCP_port>] [realm <string>]
Syntax
Options
kdc-domain
The name of a host running the KDC (Key Distribution Center) for the specified realm.
The host name that you specify must either be defined in the IOLAN’s Host Table
(with an IP address) or be resolvable by a DNS server.
port
The port that the Kerberos server listens to for authentication requests. If no port is
specified, the default port 88 is used.
realm
The Kerberos realm is the Kerberos host domain name, in upper-case letters.
Set Authentication LDAP
Description Configures LDAP authentication settings.
User Level Admin
set authentication ldap [base <string>]
Syntax
[host <hostname/IP_addr>] [port <TCP_port>] [tls on|off]
[tls-port <TCP_port>]
Options
base
The domain component (dc) that is the starting point for the search for user
authentication.
host
The name or IP address of the LDAP host. If you use a host name, that host must either
have been defined in the IOLAN’s Host Table (with an IP address) or be resolvable by
a DNS server. If you are using TLS, you must enter the same string you used to create
the LDAP certificate that resides on your LDAP server.
port
The port that the LDAP host listens to for authentication requests. The default port is
389.
tls
Enables/disables the Transport Layer Security (TLS) with the LDAP host.
tls-port
Specify the port number that LDAP will use for TLS. The default is port 636.
34
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Authentication Commands
Set Authentication NIS
Description Sets NIS authentication parameters.
User Level Admin
set authentication nis [domain <string>] [primary <config_host>]
[secondary <config_host>]
Syntax
Options
domain
The NIS domain name.
primary
The primary NIS host that is used for authentication.
secondary
The secondary NIS host that is used for authentication, should the primary NIS host fail
to respond.
Add RADIUS
Description Adds an accounting or authentication RADIUS host.
User Level Admin
add radius accounting-host <config_host> secret
add radius auth-host <config_host> secret
Syntax
Options
accounting-host
The first time this command is entered, this is the name of the primary RADIUS
accounting host.
The second time this command is entered, this is the name of the secondary RADIUS
authentication host.
auth-host
The first time this command is entered, this is the name of the primary RADIUS
authentication host.
The second time this command is entered, this is the name of the secondary RADIUS
authentication host, should the first RADIUS host fail to respond.
secret
The secret (password) shared between the IOLAN and the RADIUS authentication host.
After typing the command secretand pressing Enter, you will be prompted to enter
the secret and then re-enter the secret.
Delete RADIUS
Description Deletes an accounting or authentication RADIUS host.
User Level Admin
delete radius accounting <accounting_host>
delete radius authentication <authentication_host>
Syntax
Options
accounting
Deletes the specified accounting host from the RADIUS authentication settings.
authentication
Deletes the specified authentication host from the RADIUS authentication settings.
Server Commands 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Authentication Commands
Set Authentication RADIUS
Description Sets RADIUS parameters.
User Level Admin
set authentication radius [accounting on|off]
Syntax
[acct-authenticator on|off] [acct-port <UDP_port>]
[auth-port <UDP_port>] [nas-identifier <nas_id>]
[nas-ip-address auto|specify <ipv4_address>]
[nas-ipv6-address auto|specify <ipv6_address>] [retry <integer>]
[timeout <integer>]
Options
accounting
Enables/disables RADIUS accounting.
acct-authenticator
Enables/disables whether or not the IOLAN validates the RADIUS accounting
response.
acct-port
The port that the RADIUS host listens to for accounting requests. The default port is
1813.
auth-port
The port that the RADIUS host listens to for authentication requests. The default port is
1812.
nas-identifier
This is the string that identifies the Network Address Server (NAS) that is originating
the Access-Request to authenticate a user.
Field Format: Maximum 31 characters, including spaces
nas-ip-address auto
When specified, the IOLAN will send the IOLAN’s Ethernet 1 IPv4 address to the
RADIUS server. This is the default.
nas-ip-address specify <ipv4_address>
When specified, the IOLAN will send the specified IPv4 address to the RADIUS server.
The default is 0.0.0.0.
nas-ipv6-address auto
When specified, the IOLAN will send the IOLAN’s IPv6 address to the RADIUS
server. This is the default.
nas-ipv6-address specify <ipv6_address>
When specified, the IOLAN will send the specified IPv6 address to the RADIUS server.
retry
The number of times the IOLAN tries to connect to the RADIUS server before erroring
out. Valid values are 0-255. The default is 5.
timeout
The time, in seconds, that the IOLAN waits to receive a reply after sending out a
request to a RADIUS accounting or authentication host. If no reply is received before
the timeout period expires, the IOLAN will retry the same host up to and including the
number of retry attempts. Valid values are 1-255. The default is 3 seconds.
36
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Authentication Commands
Set Authentication TACACS+
Description Configures TACACS+ authentication settings.
User Level Admin
set authentication tacacs+ [port <TCP_port>]
[primary <config_host>] [secondary <config_host>]
Syntax
[secret <string>]
Options
port
The port number that TACACS+ listens to for authentication requests. The default port
number is 49.
primary
The primary TACACS+ host that is used for authentication.
secondary
The secondary TACACS+ host that is used for authentication, should the primary
TACACS+ host fail to respond.
secret
The TACACS+ shared secret is used to encrypt/decrypt TACACS+ packets in
communications between two devices. The shared secret may be any alphanumeric
string. Each shared secret must be configured on both client and server sides.
Set Authentication SecurID
Description Configures SecurID authentication settings.
User Level Admin
set authentication securid primary [host <config_host>]
[port <TCP_port>] [encryption des|sdi] [legacy on|off]
Syntax
set authentication securid replica [host <config_host>]
[port <TCP_port>] [encryption des|sdi] [legacy on|off]
set authentication securid reset secret
Options
primary host
The first SecurID server that is tried for user authentication.
replica host
If the first SecurID server does not respond to an authentication request, this is the next
SecurID server that is tried for user authentication.
port
The port number that SecurID listens to for authentication requests. The default port
number is 5500.
encryption
You can specify either SDI or DES encryption for SecurID server communication. The
default is SDI encryption.
legacy
If you are running SecurID 3.x or 4.x, you need to run in Legacy Mode. If you are
running SecurID 5.x or above, do not select Legacy Mode.
reset secret
Resets the SecurID secret (password) in the IOLAN.
Server Commands 37
Download from Www.Somanuals.com. All Manuals Search And Download.
TruePort Baud Commands
Show Authentication
Description Shows the authentication settings. If you type just the show authentication
command, the configured primary and secondary authentication methods are displayed.
User Level Admin
show authentication radius|ldap|tacacs+|nis|kerberos|securid
Syntax
Option
radius|ldap|tacacs+|nis|kerberos|securid
Displays the authentication settings for the specified authentication method.
TruePort Baud Commands
Set TruePort Remap-Baud
Description This command allows for the remapping of the baud rate being specified by the Serial
application to a different value on the physical serial port on the IOLAN.
User Level Admin
set trueport remap-baud
Syntax
50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|19200|
38400
50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|19200|
38400|57600|115200|230400|28800|[custom <baud_rate]
Options
50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|19200|38400
The configured baud rate of the TruePort client.
50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|19200|38400|
57600|115200|230400|28800|[custom <baud_rate>]
The actual baud rate that runs between the IOLAN and the connected serial device. You
can also specify a custom baud rate; valid values are 50 - 1843200.
Show TruePort
Description Shows the IOLAN TruePort remapping table.
User Level Normal, Admin
show trueport
Syntax
38
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Email Commands
Email Commands
Set Email-Alert Server
Description Configures email alert settings for the server.
User Level Admin
set email-alert server [from <email_addr>]
Syntax
[level emergency|alert|critical|error|warning|notice|info|debug]
[mode on|off] [to <email_addr>] [reply-to <email_addr>]
[smtp-host <string>] [subject <string>]
Options
from
This will be the contents of the from field in the generated email.
This field will be specified in the fromfield of the email message sent by the IOLAN.
level
Choose the event level that triggers an email notification:
z
z
z
z
z
z
z
z
Emergency
Alert
Critical
Error
Warning
Notice
Info
Debug
The list is in decreasing order of priority (Emergency has the highest priority). You are
selecting the lowest notification level; therefore, when you select Debug, you will get
an email notification for all events that trigger a message.
mode
Determines whether or not email notification is turned on. Default is Off.
to
An email address or list of email addresses that will receive the email notification.
reply-to
The email address to whom all replies to the email notification should go.
smtp-host
The SMTP host (email server) that will process the email notification request. This can
be either a host name defined in the IOLAN host table or the SMTP host IP address.
subject
A text string, which can contain spaces, that will display in the Subject field of the
email notification.
If the text string contains spaces, enclose the string in quotes.
Show Email-Alert Server
Description Shows how the server email alert is configured.
User Level Admin
show email-alert server
Syntax
Server Commands 39
Download from Www.Somanuals.com. All Manuals Search And Download.
Clustering Commands
Clustering Commands
Add Clustering Slave-IP
Description Adds a slave IOLAN to the clustering group.
User Level Admin
add clustering slave-ip <IPv4_address>
Syntax
number-of-ports 1|2|4|8|16|24|32|48 [protocol telnet|ssh]
[starting-master-tcp-port <10001-65535>]
[starting-slave-ds-port <10001-65535>]
Options
<IPv4_address>
Specify the IP address of the clustering slave you wish to modify. This clustering slave
must already exist in the clustering group. The IP address must be in a valid IPv4
format.
number-of-ports
Specify the port number that you wish to modify on this clustering slave.
protocol
Specify the protocol that will be used to access the Slave IOLAN port, SSH or Telnet.
starting-master-tcp-port
Specify this parameter if you wish to change the name associated with this slave port.
starting-slave-ds-port
Specify this parameter if you wish to change the slave-ds-port associated with this
slave port. This should match the port number configured for this port on the salve
IOLAN.
Delete Clustering Slave-IP
Description Deletes a Slave IOLAN from the clustering group. Type
delete clustering slave-ip ?to get a list of Slave IOLAN IP addresses.
User Level Admin
delete clustering slave-ip <IPv4_address>
<IPv4_address>
Syntax
Option
Specify the IP address of the clustering slave you wish to modify. This clustering slave
must already exist in the clustering group. The IP address must be in a valid IPv4
format.
40
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Clustering Commands
Set Clustering Slave-IP
Description Modify the parameter associated with a specific port in a clustering group.
User Level Admin
set clustering slave-ip <IPv4_address> port <number>
[master-tcp-port <10001-65535>] [name <port_name>]
Syntax
[protocol telnet|ssh|not-used] [slave-ds-port <10001-65535>]
Options
<IPv4_address>
Specify the IP address of the clustering slave you wish to modify. This clustering slave
must already exist in the clustering group. The IP address must be in a valid IPv4
format.
port
Specify the port number that you wish to modify on this clustering slave.
master-tcp-port
Specify this parameter if you wish to change the name associated with this slave port.
name
Specify this parameter if you wish to change the name associated with this slave port.
protocol
Specify this parameter if you wish to change the protocol used to access this slave port.
Valid options are SSH, Telnet or not used if you wish to disable access to this port.
slave-ds-port
Specify this parameter if you wish to change the slave-ds-port associated with this
slave port. This should match the port number configured for this port on the salve
IOLAN.
Show Clustering Slave-IP
Description Show a Slave IOLANs clustering group settings. Type
show clustering slave-ip ?to get a list of Slave IOLAN IP addresses.
User Level Admin
show clustering slave-ip <IPv4_address> [get-port-names]
[get-port-names-and-save]
Syntax
Options
<IPv4_address>
Specify the IP address of the clustering slave you wish to modify. This clustering slave
must already exist in the clustering group. The IP address must be in a valid IPv4
format.
get-port-names
Retrieves the port/line names from the specified Slave IOLAN.
get-port-names-and-save
Retrieves the port/line names from the specified Slave IOLAN and saves them in the
Slave IOLAN clustering configuration.
Server Commands 41
Download from Www.Somanuals.com. All Manuals Search And Download.
Dynamic DNS Commands
Dynamic DNS Commands
Set Dynamic-DNS
Description Configures the dynamic DNS parameters.
User Level Admin
set dynamic-dns [on|off]
Syntax
[connection-method http|http-port-8245|https]
[hostname <hostname>] [username <username>]
[password <password>] [system-type dynamic|static|custom]
[wildcard enable|disable|nochange]
Options
connection-method
Specify how the IOLAN is going to connect to the DynDNS.org server, via HTTP,
HTTP through Port 8245, or HTTPS.
hostname
Specify the registered hostname with DynDNS.org that will be updated with the
IOLAN’s IP address should it change. Put in the full name; for example,
mydeviceserver.dyndns.org.
username
Specify the user name used to access the DynDNS.org server.
password
Specify the password used to access the DynDNS.org server.
system-type
Specify how your account was set up with DynDNS.org, using a Dynamic, Static, or
Custom IP address schema.
wildcard
Adds an alias to *.yourhost.ourdomain.extpointing to the same IP address as
entered for yourhost.ourdomain.ext.
Set Dynamic-DNS SSL
Description Sets the SSL/TLS parameters for the connection between the IOLAN and the DNS
server.
User Level Admin
set dynamic-dns ssl [verify-peer on|off]
[validation-criteria
Syntax
country <code>|state-province <text>|locality <text>
|organisation <text>|organisation-unit <text>
|common-name <text>|email <email_addr>]
Options
verify-peer
Enable this option when you want the Validation Criteria to match the Peer Certificate
for authentication to pass. If you enable this option, you need to download an SSL/TLS
certificate authority (CA) list file to the IOLAN.
validation-criteria
Any values that are entered in the validation criteria must match the peer certificate for
an SSL connection; any fields left blank will not be validated against the peer
certificate.
42
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Dynamic DNS Commands
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the peer SSL/TLS certificate.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the peer SSL/TLS
certificate.
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the peer SSL/TLS certificate.
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
Server Commands 43
Download from Www.Somanuals.com. All Manuals Search And Download.
Dynamic DNS Commands
Set Dynamic-DNS SSL Cipher-Suite
Description Sets the SSL/TLS cipher suite parameters for the connection between the IOLAN and
the DNS server.
User Level Admin
set dynamic-dns ssl cipher-suite
option1|option2|option3|option4|option5
encryption any|aes|3des|des|arcfour|arctwo|none
min-key-size 40|56|64|128|168|256
max-key-size 40|56|64|128|168|256
key-exchange any|rsa|edh-rsa|edh-dss|adh
hmac any|sha1|md5
Syntax
Options
option1|option2|option3|option4|option5
Sets the priority of the cipher suite, with option1being highest priority and option5
lowest priority.
encryption
Select the type of encryption that will be used for the SSL connection:
z
z
z
z
z
z
z
Any—Will use the first encryption format that can be negotiated.
AES
3DES
DES
ARCFOUR
ARCTWO
None—Removes any values defined for the cipher option.
The default value is Any.
min-key-size
The minimum key size value that will be used for the specified encryption type. The
default is 40.
max-key-size
The maximum key size value that will be used for the specified encryption type. The
default is 256.
key-exchange
The type of key to exchange for the encryption format:
z
Any—Any key exchange that is valid is used (this does not, however, include ADH
keys).
z
z
z
z
RSA—This is an RSA key exchange using an RSA key and certificate.
EDH-RSA—This is an EDH key exchange using an RSA key and certificate.
EDH-DSS—This is an EDH key exchange using a DSA key and certificate.
ADH—This is an anonymous key exchange which does not require a private key
or certificate. Choose this key if you do not want to authenticate the peer device,
but you want the data encrypted on the SSL/TLS connection.
The default is Any.
44
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Commands
hmac
Select the key-hashing for message authentication method for your encryption type:
z
z
z
Any
MD5
SHA1
The default is Any.
Show Dynamic-DNS
Description Shows the dynamic DNS settings.
User Level Admin
show dynamic-dns
Syntax
PCI Commands
Set PCI Card
Description Sets the type of card in the PCI slot.
User Level Admin
set pci card none|modem|wireless-wan
Syntax
Option
card
Specify the type of card which is inserted in the PCI slot. Choices are modem for an
IOLAN modem card, wireless-wan for a wireless WAN card. Choose none or leave
the default modem if no card is inserted in the PCI slot.
Show PCI
Description Displays the PCI line settings.
User Level Admin
show pci
Syntax
Server Commands 45
Download from Www.Somanuals.com. All Manuals Search And Download.
PCI Commands
Set PCI Wireless-WAN
Description Configures the wireless WAN parameters.
User Level Admin
set pci wireless-wan [access-point-name <name>]
[init-string <modem_init_string>]
Syntax
[model sierra-wireless-aircard-881|sony-ericsson-pc300|sierra|
sony-ericsson|standard|custom]
[password <password>][phone-number <phone_number>]
[user <username>]
Options
access-point-name
Specify the APN required by your internet provider to access their network. See the
internet provider documentation for more information.
init-string
Specify the initialisation string required by your internet service provider for your
wireless WAN card.
model
Specify the wireless WAN card you are using. If the wireless WAN card you are using
is not listed, try the standard driver. If that does not work, look at the Perle website for a
custom driver.
password
Specify the password required by your internet provider to access their network.
phone-number
Specify the phone number provided by your service provider to access their wireless
network. The phone number will probably take a format similar to *99***1#.
user
Specify the name required by your internet provider to access their network.
Show Wireless-WAN
Description Displays the wireless WAN settings.
User Level Admin
show wireless-wan
Syntax
46
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Commands
IPv6 Commands
Set IPv6
Description Configures the basic IPv6 settings.
User Level Admin
set ipv6 [dhcpv6-settings ipv6-address on|off]
[dhcp-settings network-prefix on|off]
Syntax
[auto-obtain-dns-ipv6 on|off] [eth1|eth2]
[enable-ipv6-addressing on|off] [obtain-using auto-ipv6|dhcpv6]
Options
dhcpv6-settings
Determines the types of information that the IOLAN will accept from the DHCPv6
server, IPv6 address(es) and/or network prefix(es).
ivp6-address
When enabled, the IOLAN will accept IPv6 address(es) from the DHCPv6 server. This
is offby default.
network-prefix
When enabled, the IOLAN will accept the network prefix from the DHCPv6 server.
This is offby default.
eth1|eth2
Configures the IPv6 settings for the IOLAN’s Ethernet interface 1 and/or Ethernet
interface 2 (SCS models only) connection(s).
enable-ipv6-addressing
When enabled, you can configure the IOLAN to obtain the IPv6 address(es) using IPv6
Autoconfiguration or a DHCPv6 server.
Default: Enabled
obtain-using auto-ipv6|dhcpv6
z
auto-ipv6—When enabled, the IOLAN will send out a Router Solicitation
message. If a Router Advertisement message is received, the IOLAN will configure
the IPv6 address(es) and configuration parameters based on the information
contained in the advertisement. If no Router Advertisement message is received,
the IOLAN will attempt to connect to a DHCPv6 server to obtain IPv6 addresses
and other configuration parameters. This is the default.
z
dhcpv6—When enabled, requests IPv6 address(es) and configuration information
from the DHCPv6 server.
Show IPv6
Description Shows the IPv6 settings.
User Level Admin
show ipv6 [eth1|eth2]
eth1|eth2
Syntax
Option
Displays the configuration IPv6 information for the specified Ethernet interface.
Server Commands 47
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Commands
Add Custom-IPv6
Description
User Level Admin
add custom-ipv6 [eth1|eth2] method auto
network-prefix <network_prefix>
Syntax
[prefix-bits <0-64>] [router-advertisement on|off]
add custom-ipv6 [eth1|eth2] method manual
ipv6-address <ipv6_address> [prefix-bits <0-128>]
[router-advertisement on|off]
Options
eth1|eth2
Configures the custom IPv6 settings for the IOLAN’s Ethernet interface 1 or Ethernet
interface 2 (SCS models only) interface.
method auto
When this option is specified, the IOLAN will derive an IPv6 address from the entered
network prefix and the IOLAN’s MAC address. This is the default option.
network-prefix
Specify the IPv6 network prefix. The IOLAN will derive the complete IPv6 address
from the entered network prefix and the IOLAN’s MAC address.
prefix-bits (auto)
Specify the network prefix bits for the IPv6 address.
Range: 0-64
Default: 64
method manual
Specify this option when you want to enter a specific IPv6 address.
ipv6-address
Specify the complete IPv6 address.
Field Format: IPv6 address
prefix-bits (manual)
Specify the network prefix bits for the IPv6 address.
Range: 0-128
Default: 64
router-advertisement
When enabled, the IPv6 address is advertised when the IPv6-router-advertisement
parameter is enabled.
48
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Commands
Set Custom-IPv6
Description Configures custom IPv6 network and IP addresses.
User Level Admin
set custom-ipv6 [eth1|eth2] <config_ipv6_address> method auto
network-prefix <network_prefix>
Syntax
[prefix-bits <0-64>] [router-advertisement on|off]
set custom-ipv6 [eth1|eth2] <config_ipv6_address> method manual
ipv6-address <ipv6_address> [prefix-bits <0-128>]
[router-advertisement on|off]
Options
eth1|eth2
Configures the custom IPv6 settings for the IOLAN’s Ethernet interface 1 or Ethernet
interface 2 (SCS models only) interface.
method auto
When this option is specified, the IOLAN will derive an IPv6 address from the entered
network prefix and the IOLAN’s MAC address. This is the default option.
network-prefix
Specify the IPv6 network prefix. The IOLAN will derive the complete IPv6 address
from the entered network prefix and the IOLAN’s MAC address.
prefix-bits (auto)
Specify the network prefix bits for the IPv6 address.
Range: 0-64
Default: 64
method manual
Specify this option when you want to enter a specific IPv6 address.
ipv6-address
Specify the complete IPv6 address.
Field Format: IPv6 address
prefix-bits (manual)
Specify the network prefix bits for the IPv6 address.
Range: 0-128
Default: 64
router-advertisement
When enabled, the IPv6 address is advertised when the IPv6-router-advertisement
parameter is enabled.
Delete Custom-IPv6
Description Deletes the specified custom IPv6 address. To see a list of configured IPv6 addresses,
type the command delete custom-ipv6 ?.
User Level Admin
delete custom-ipv6 <config_ipv6_address> [eth1|eth2]
eth1|eth2
Syntax
Option
Deletes the specified custom IPv6 address. You must specify the Ethernet interface for
SCS models.
Server Commands 49
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Router Advertisements
IPv6 Router Advertisements
Set IPv6-Router-Advertisement
Description Configures IPv6 router advertisements.
User Level Admin
set ipv6-router-advertisement [eth1|eth2] on|off [dhcpv6 off|on]
[dhcpv6-cfg-options off|on]
Syntax
Options
ipv6-router-advertisement
When enabled, the IOLAN will periodically send IPV6 Router Advertisement messages
and respond to Router Solicitation messages. The Router Advertisement message can
be configured to contain any of the following information:
z
z
z
DHCPv6—Use the DHCPv6 server to obtain additional IPV6 address(es) and
configuration parameters.
DHCPv6 Configuration Options—Use DHCPv6 server to obtain additional
configuration parameters.
Network Prefixes—Advertise the selected custom configured network prefixes.
Default: Disabled
eth1|eth2
Configures the IPv6 router advertisement settings for the IOLAN’s Ethernet interface 1
or Ethernet interface 2 (SCS models only) interface.
dhcpv6
When enabled, the Router Advertisement message indicates to use the DHCPv6 server
for obtaining additional IPv6 addresses and configuration parameters.
Default: Disabled
dhcpv6-cfg-options
When enabled, the Router Advertisement message indicates to use the DHCPv6 server
to obtain additional configuration parameters.
Default: Disabled
Show IPv6-Router-Advertisement
Description Displays the IPv6 router advertisement settings.
User Level Admin
show ipv6-router-advertisement [eth1|eth2]
eth1|eth2
Syntax
Option
Displays the IPv6 router advertisement settings for the IOLAN’s Ethernet interface 1 or
Ethernet interface 2 (SCS models only) interface.
50
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
User Commands
Chapter
3
3
This chapter defines all the CLI commands available to users who are logged into the IOLAN.
Commands for Users Logged Into the IOLAN
Admin
Description Changes a Normal-level user to the Admin user. When you press Enter after you type
this command, you will be prompted for the Admin password.
User Level Normal
admin
Syntax
Help
Description Displays help on using the command line interface (CLI).
User Level Restricted, Normal, Admin
help
Syntax
Kill Line
Description Restarts a line. On IOLANs with more than 1 port, you can specify a port number and
then a range of ports; for example, kill line 4, 10-13, 15. This command can
also be used to reset the internal modem on the IOLAN. The internal modem is
addressed as last serial port +1 (i.e., on an SDS 3M, the modem is line 4). On single
port models, use the command kill line.
User Level Normal, Admin
kill line *|<number>|<number range>
Syntax
Note: the * is a wildcard meaning all lines.
Kill Session
Description Kills an active session.
User Level Restricted, Normal, Admin
kill session 1|2|3|4
Syntax
Options
1|2|3|4
The number of the session you want to kill.
Logout
Description Logs the user out from the IOLAN.
User Level Restricted, Normal, Admin
logout
Syntax
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
Menu
Description Switches from a command line based interface to Menu mode of operation.
User Level Restricted, Normal, Admin
menu
Syntax
Ping
Description This command checks to see if a given host is reachable via an IP message. The
specific message used is called a ping.
User Level Normal, Admin
ping <hostname/IP_address> [<packet_size>] [<#_of_packets>]
Syntax
Options
<hostname/IP_address>
The name (DNS resolvable host name) or IP address of the machine you are trying to
ping.
<packet_size>
Enter the number of data bytes to be sent. The default is 100 bytes.
<#_of_packets>
Enter the number of the packets you want to send. The default is 10.
Resume
Rlogin
Description Resumes a started session.
User Level Restricted, Normal, Admin
resume 1|2|3|4
Syntax
Options
1|2|3|4
The number of the session you want to resume.
Description Starts an rlogin session to the specified host/IP address.
User Level Normal, Admin
rlogin <hostname/IP_address> [termtype <terminal_name>]
[user <string>]
Syntax
Options
<hostname/IP_address>
The name of the target host.
termtype
Type of terminal attached to this line; for example, ansi or wyse60.
user
The name of the user logging into the rlogin session.
Screen
Description Switches from a command line based interface to Menu mode of operation.
User Level Restricted, Normal, Admin
screen
Syntax
52
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
Set Termtype
Description Sets the type of terminal being used for the current session.
User Level Normal, Admin
set termtype
Syntax
wyse60|vt100|ansi|dumb|tvi925|ibm3151te|vt320|hp700|term1|term2|
term3
Option
wyse60|vt100|ansi|dumb|tvi925|ibm3151te|vt320|hp700|term1|term2|term3
Specifies the type of terminal connected to the line:
z
z
z
z
z
z
z
z
z
Dumb
WYSE60
VT100
ANSI
TVI925
IBM3151TE
VT320 (specifically supporting VT320-7)
HP700 (specifically supporting HP700/44)
Term1, Term2, Term3 (user-defined terminals)
Set User
Description Sets the current users settings.
User Level Normal, Admin
set user . [hotkey-prefix <00-7f>] [language english|customlang]
[routing none|send|listen|send-and-listen] [password]
Syntax
Options
hotkey-prefix
The prefix that a user types to control the current session. The default value is hex 01,
which corresponds to Ctrl-a (^a) (hex value 02 would be Ctrl-b (^b), etc.):
z
^a number—To switch from one session to another, press ^a and then the required
session number. For example, ^a 2 would switch you to session 2. Pressing ^a 0
will return you to the IOLAN Menu.
z
z
z
z
^a n—Display the next session. The current session will remain active. The lowest
numbered active session will be displayed.
^a p—Display the previous session. The current session will remain active. The
highest numbered active session will be displayed.
^a m—To exit a session and return to the IOLAN. You will be returned to where
you left off. The session will be left running.
^a l—(Lowercase L) Locks the line until the user unlocks it. The user is prompted
for a password (any password, excluding spaces) and locks the line. Next, the user
must retype the password to unlock the line.
z
^r—When you switch from a session back to the Menu, the screen may not be
redrawn correctly. If this happens, use this command to redraw it properly. This is
always Ctrl R, regardless of the Hotkey Prefix.
The User Hotkey Prefix value overrides the Line Hotkey Prefix value. You can use the
Hotkey Prefix keys to lock a line only when the line Lock parameter is On.
language
You can specify whether a user will use English or Customlang as the language that
appears in the Menu, CLI, or WebManager. The IOLAN supports one custom language
that must be downloaded to the IOLAN; otherwise, Customlang defaults to English.
User Commands 53
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
routing
Determines the routing mode used for RIP packets on the PPP and SLIP interfaces for
this user. Values are:
z
z
z
z
None—RIP packets are neither received nor sent by the IOLAN.
Send—RIP packets can only be sent by the IOLAN.
Listen—RIP packets can only be received by the IOLAN.
Send and Listen—RIP packets are sent and received by the IOLAN.
password
The password the user will need to enter to login to the IOLAN. This case-sensitive
field accepts a maximum of 16 characters.
Set User Session
Description Sets the current users session settings.
User Level Normal, Admin
set user . session 1|2|3|4|* [auto on|off]
[type off|telnet|rlogin|ssh]
Syntax
set user . session 1|2|3|4|* telnet-options [host <config_host>]
[port <TCP_port>] [termtype <terminal_name>] [line-mode on|off]
[map-cr-crlf on|off] [local-echo on|off] [echo <00-7f>]
[eof <00-7f>] [erase <00-7f>] [intr <00-7f>] [quit <00-7f>]
set user . session 1|2|3|4|* rlogin-options [host <config_host>]
[termtype <terminal_name>]
set user . session 1|2|3|4|* ssh-options [host <config_host>]
[port <TCP_port>] [termtype <terminal_name>]
[protocol ssh-1|ssh-2|ssh-2/1] [compression on|off]
[verbose on|off] [auto-login on|off] [name <string>]
[password <string>] [ssh-1-cipher 3des|des|blowfish]
[authentication rsa on|off] [authentication dsa on|off]
[authentication keyboard-interactive on|off]
set user . session 1|2|3|4|* ssh-options
ssh-2-cipher-list <3des blowfish cast aes arcfour>
Options
session
Specifies the session number (or all, *) that you are configuring.
auto
Specify whether or not the session(s) will start automatically when the user logs into the
IOLAN.
telnet-options
See Set Telnet-Client in the IOLAN User’s Guide.
rlogin-options
See Set Rlogin-Client in the IOLAN User’s Guide.
ssh-options
See Set SSH-Client in the IOLAN User’s Guide.
54
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
Show Line Users
Description Shows the users who are on the line.
User Level Admin
show line users
Syntax
SSH
Description Starts an SSH session to the specified host/IP address.
User Level Normal, Admin
ssh <hostname/IP_address> [<TCP_port>]
Syntax
[termtype <terminal_name>] [authentication rsa on|off]
[authentication dsa on|off]
[authentication keyboard-interactive on|off]
[compression on|off] [protocol ssh-1|ssh-2|ssh-2,1]
[ssh-1-cipher 3des|des|blowfish]
[ssh-2-cipher-list <3des blowfish cast aes arcfour> end-list]
[user <name>] [verbose on|off]
Options
<hostname/IP_address>
The name (resolvable via DNS) or IP address of the host you wish to connect to with
SSH.
<TCP_port>
The port number the target host is listening on for incoming connections. The default
for SSH is port number 22.
termtype
Type of terminal attached to this line; for example, ANSI or WYSE60.
authentication rsa
An authentication method used by SSH version 1 and 2. When enabled, an SSH client
session will try to authenticate via RSA.
authentication dsa
An authentication method used by SSH version 2. When enabled, an SSH client session
will try to authenticate via DSA.
authentication keyboard-interaction
The user types in a password for authentication.Used for SSH2 only.
compression
Requests compression of all data. Compression is desirable on modem lines and other
slow connections, but will only slow down things on fast networks.
protocol
Specify whether you are using SSH-1, SSH-2, or a combination of the two protocols,
SSH-2, SSH-1.
ssh-1-cipher
Select the encryption method (cipher) that you want to use for your SSH version 1
connection:
z
z
3DES
Blowfish
User Commands 55
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
ssh-2-cipher-list
Select the order of negotiation for the encryption method (ciphers) that the IOLAN will
use for the SSH version 2 connection:
z
z
z
z
z
3DES
Blowfish
AES
Arcfour
CAST
user
The name of the user logging into the SSH session.
verbose
Displays debug messages on the terminal.
Syslog Console
Description Starts/stops or displays the status of the syslog console.
User Level Admin
syslog console start|stop
Syntax
syslog console status
Options
start|stop
Start or stop console logging. When console logging is enabled, syslog messages will
be echoed to the current console. These messages are filtered based on the level set in
the (remote) syslog options.
status
Displays the current console logging status (enabled or disabled).
Show Sessions
Description Shows available sessions.
User Level Restricted, Normal, Admin
show sessions
Syntax
Show Termtype
Description Shows the terminal type for the current session.
User Level Admin
show termtype
Syntax
Start
Description Starts a predefined session. Only inactive sessions are displayed.
User Level Restricted, Normal, Admin
start 1|2|3|4
Syntax
Options
1|2|3|4
The number of the session that you want to start.
56
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands for Users Logged Into the IOLAN
Telnet
Description Starts a telnet session to the specified host/IP address.
User Level Normal, Admin
telnet <hostname/IP_address> [<TCP_port>]
Syntax
[termtype <terminal_name>] [line-mode on|off]
[map-cr-crlf on|off] [local-echo on|off]
[echo <00-7f>] [eof <00-7f>] [erase <00-7f>] [intr <00-7f>]
[quit <00-7f>] [escape <00-7f>]
Options
<hostname/IP_address>
The name (resolvable via DNS) or IP address of the host you wish to connect to with
Telnet.
<TCP_port>
The port number the target host is listening on for incoming connections. The default
for Telnet is port number 23.
termtype
Type of terminal attached to this line; for example, ANSI or WYSE60.
line-mode
When On, keyboard input is not sent to the remote host until Enter is pressed,
otherwise input is sent every time a key is pressed. Default is Off.
map-cr-crlf
Maps carriage returns (CR) to carriage return line feed (CRLF). The default value is
Off.
local-echo
Toggles between local echo of entered characters and suppressing local echo. Local
echo is used for normal processing, while suppressing the echo is convenient for
entering text that should not be displayed on the screen, such as passwords. This
parameter can only be used when Line Mode is On. Default is Off.
echo
Defines the echo character. When Line Mode is On, typing the echo character echoes
the text locally and sends only completed lines to the host. This value is in hexadecimal
with a default value of 5 (ASCII value ^E).
eof
Defines the end-of-file character. When Line Mode is On, entering the EOF character
as the first character on a line sends the character to the remote host. This value is in
hexadecimal with a default value of 4 (ASCII value ^D).
erase
Defines the erase character. When Line Mode is Off, typing the erase character erases
one character. This value is in hexadecimal with a default value of 8 (ASCII value ^H).
intr
Defines the interrupt character. Typing the interrupt character interrupts the current
process. This value is in hexadecimal with a default value of 3 (ASCII value ^C).
quit
Defines the quit character. Typing the quit character closes and exits the current telnet
session. This value is in hexadecimal with a default value of 1c (ASCII value FS).
User Commands 57
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
escape
Defines the escape character. Returns you to the command line mode. This value is in
hexadecimal with a default value of 1d (ASCII value GS).
Version
Description Displays firmware version and build.
User Level Normal, Admin
version
Syntax
Configuring Users
Add User
Description For units with 4 or less serial ports, you can configure up to 4 users. For units with 8 or
more serial ports, the maximum number of users which can be added is 48. This is in
addition to the adminuser.
User Level Admin
add user <username>
Syntax
Option
<username>
The name of the user, without spaces. When you finish the command and press Enter,
you will be prompted to enter and re-enter a password for the user.
Delete User
Description Deletes a user.
User Level Admin
delete user <config_user>
Syntax
Option
<config_user>
You can see a list of users that can be deleted by typing delete user ?. You can not
delete the adminuser.
58
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
Set Default User
Description Configures the Default User. When adding a new user, the profile of the default user
will be used to assign the values of the various parameters of the new user. For example
if you set the serviceparameter of the default user to ppp, when a new user is added,
their service parameter will be set to ppp.
User Level Admin
set default user [callback on|off] [framed-compression on|off]
[framed-ip <IPv4_address>]
Syntax
[framed-interface-id <IPv6_interface_id>]
[framed-mtu <64-1500>] [hotkey-prefix <00-7f>]
[idle-timer <0-4294967>]
[host-ip None|<IP_address>|<config_host>]
[language english|customlang]
[level admin|normal|restricted|menu]
[line-access readin|readout|readwrite [on|off]|<line(s)> [0]]
[netmask <IPv4_address>] [phone-number <phone_number>]
[routing none|send|listen|send-and-listen]
[service dsprompt|telnet|tcp-clear|rlogin|ppp|slip|ssh|ssl-raw]
[sess-timer <0-4294967>] [port tcp-clear|telnet|ssh|ssl-raw
<TCP_port>] [access-clustered-ports on|off]
Options
callback
When On, enter a phone number for the IOLAN to call the user back (the Callback
parameter is unrelated to the Line Dial parameter).
Note: the IOLAN will allow callback only when a user is authenticated. If the protocol
over the link does not provide authentication, there will be no callback. Therefore, when
the Line Service is set to PPP, you must use either PAP or CHAP, because these
protocols provide authentication. The default is Off.
The IOLAN supports another type of callback, Roaming Callback, which is
configurable when the Line Service is set to PPP.
framed-compression
Used for User Service PPP or SLIP, determines whether Van Jacobsen Compression is
used on the link. VJ compression is a means of reducing the standard TCP/IP header
from 40 octets to approximately 5 octets. This gives a significant performance
improvement, particularly when interactive applications are being used. For example,
when the user is typing, a single character can be passed over the link with a packet as
small as 5 octets as opposed to 40 octets when no JV compression is used. VJ
Compression has little effect on other types of links, such as ftp, where the packets are
much larger. The Framed Compression value will be used in preference to the VJ
Compression value set for a Line. The default is Off.
framed-ip
Used for User Service PPP or SLIP, sets the IP address of the remote user. Enter the
address in dot decimal notation as follows:
z
255.255.255.254 (default)—The IOLAN will use the Remote IP Address set in
the PPP settings for the line.
z
255.255.255.255—When the User Service is PPP, the IOLAN will allow the
remote machine to specify its IP address (overriding the Remote IP Address
configured in the line, PPP settings). When the User Service is SLIP, the IOLAN
will use the Remote IP Address set for the line (no negotiation).
z
n.n.n.n—(where n is a number) Enter the IP address of your choice. This IP
address will then be used in preference to the Remote IP Address set for a line.
framed-interface-id
Used for User Service PPP, sets the IPv6 address of the remote user.
User Commands 59
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
framed-mtu
Used for User Service PPP or SLIP, specifies the maximum size of packets, in bytes,
being transferred across the link. On noisy links it might be preferable to fragment large
packets being transferred over the link, since there will be quicker recovery from errors.
Depending on whether you have selected a User Service of SLIP or PPP, details are as
follows:
z
PPP—Framed MTU will be the maximum size of packets that the IOLAN port will
accept. This value is negotiated between the two ends of the link. The valid range is
64-1500. The default value is 1500 bytes.
z
SLIP—Framed MTU will be the maximum size of packets being sent by the
IOLAN. The IOLAN will send SLIP packets in the range 256-1500 bytes. The
default value is 256 bytes.
The Framed MTU value will be used in preference to the MTU/MRU values set for a
Line.
hotkey-prefix
The prefix that a user types to control the current session. The default value is hex 01,
which corresponds to Ctrl-a (^a) (hex value 02 would be Ctrl-b (^b), etc.):
z
^a number—To switch from one session to another, press ^a and then the required
session number. For example, ^a 2 would switch you to session 2. Pressing ^a 0
will return you to the IOLAN Menu.
z
z
z
z
^a n—Display the next session. The current session will remain active. The lowest
numbered active session will be displayed.
^a p—Display the previous session. The current session will remain active. The
highest numbered active session will be displayed.
^a m—To exit a session and return to the IOLAN. You will be returned to where
you left off. The session will be left running.
^a l—(Lowercase L) Locks the line until the user unlocks it. The user is prompted
for a password (any password, excluding spaces) and locks the line. Next, the user
must retype the password to unlock the line.
z
^r—When you switch from a session back to the Menu, the screen may not be
redrawn correctly. If this happens, use this command to redraw it properly. This is
always Ctrl R, regardless of the Hotkey Prefix.
The User Hotkey Prefix value overrides the Line Hotkey Prefix value. You can use the
Hotkey Prefix keys to lock a line only when the line Lock parameter is On.
idle-timer
The amount of time, in seconds, that the Idle Timer will run. Use this timer to close a
connection because of inactivity. When the Idle Timer expires, because there has been
no exchange of data within the specified time, the IOLAN will close the connection.
The default value is 0 (zero), meaning that the Idle Timer will not expire (the
connection is open permanently). The maximum value is 4294967 seconds. The User
Idle Timer will override the Line Idle Timer, with the exception of reverse SSH or
reverse Telnet sessions.
host-ip
For outbound User Services such as Telnet, Rlogin, or SSH, this is the target host name
or IP address. If no IP address is specified, the Host IP value in the Default User
configuration will be used. The default is 0.0.0.0. or None.
language
You can specify whether a user will use English or Customlang as the language that
appears in the Menu, CLI, or WebManager. The IOLAN supports one custom language
that must be downloaded to the IOLAN; otherwise, Customlang defaults to English.
60
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
level
The access that a user is allowed:
z
Admin—The admin level user has total access to the IOLAN. You can create more
than one admin user account but we recommend that you only have one. They can
monitor and configure the IOLAN.
z
Normal—The Normal level user has limited access to the IOLAN. Limited CLI
commands and Menu access are available with the ability to configure the user’s
own configuration settings.
z
z
Restricted—The Restricted level user can only access predefined sessions or
access the Easy Port Access menu.
Menu—The menu level user will only be able to access predefined session or
access the Easy Port Access menu. The Easy Port Access allows the user to
connect to the accessible line without disconnecting their initial connection to the
IOLAN. Does not have any access to CLI commands.
netmask
This is used for the PPP or SLIP Service types. Only used for IPv4. If the remote user
is on a subnet, enter the network’s subnet mask. For example, a subnet mask of
255.255.0.0.
line-access
Specifies the user access rights to each IOLAN device line. Options are:
z
z
Read/Write—Users are given read and write access to the line.
Read In—Users are given access to read only outbound data, data that is going
from the IOLAN to the device.
z
Read Out—Users are given access to read only inbound data, data that is going
from the device to the IOLAN.
Users can read data going in both directions by selecting both the Read In and Read
Out options. The on|offoption is only for 1-port models. You can disable line access
in 2-port + models by specifying 0(zero).
phone-number
The phone number the IOLAN will dial to callback the user (you must have set
Callback to On). Enter the number without spaces. To change the phone number,
overwrite the previous entry; to clear the phone number, set it to "" (double quotes
without a space).
routing
Determines the routing mode used for RIP packets on the PPP and SLIP interfaces for
this user. Values are:
z
z
z
z
None—RIP packets are neither received nor sent by the IOLAN.
Send—RIP packets can only be sent by the IOLAN.
Listen—RIP packets can only be received by the IOLAN.
Send and Listen—RIP packets are sent and received by the IOLAN.
service
The type of service that the user will use.
User Commands 61
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
sess-timer
The amount of time, in seconds, that the Session Timer will run. Use this timer to
forcibly close a user’s session (connection). When the Session Timer expires, the
IOLAN will end the connection. The default value is 0 (zero), meaning that the session
timer will not expire (the session is open permanently, or until the user logs out). The
maximum value is 4294967 seconds. The User Session Timer will override the Line
Session Timer, with the exception of reverse SSH or reverse Telnet sessions.
port
.For outbound User Services such as Telnet, SSH, TCP clear or SSL raw, this is the
target port number. The default value will change based on the type of Service selected;
the most common known port numbers are used as the default values.
access-clustered-ports
When enabled, allows the user access to IOLANs that have been configured in the
clustering group. The default is on.
Set User
Description Sets users settings. Normal-level users can configure only their own settings.
Admin-level users can configure any users settings, including their own (with the
exception of their User Level, which must stay at Admin).
User Level Normal, Admin
set user . [hotkey-prefix <00-7f>] [language english|customlang]
[password] [routing none|send|listen|send-and-listen]
Syntax
set user .|<username>|* [callback on|off]
[framed-compression on|off] [framed-ip <IPv4_address>]
[framed-interface-id <IPv6_interface_id>]
AdminUser
Only
[framed-mtu <64-1500>] [hotkey-prefix <00-7f>]
[idle-timer <0-4294967>]
[host-ip None|<IP_address>|<config_host>]
[language english|customlang]
[level admin|normal|restricted|menu] [password]
[line-access readin|readout|readwrite [on|off]|<line(s)> [0]]
[netmask <IPv4_address>] [phone-number <phone_number>]
[routing none|send|listen|send-and-listen]
[service dsprompt|telnet|tcp-clear|rlogin|ppp|slip|ssh|ssl-raw]
[sess-timer <0-4294967>] [port tcp-clear|telnet|ssh|ssl-raw
<TCP_port>] [access-clustered-ports on|off]
Options
callback
When On, enter a phone number for the IOLAN to call the user back (the Callback
parameter is unrelated to the Line Dial parameter).
Note: the IOLAN will allow callback only when a user is authenticated. If the protocol
over the link does not provide authentication, there will be no callback. Therefore, when
the Line Service is set to PPP, you must use either PAP or CHAP, because these
protocols provide authentication. The default is Off.
The IOLAN supports another type of callback, Roaming Callback, which is
configurable when the Line Service is set to PPP.
62
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
framed-compression
Used for User Service PPP or SLIP, determines whether Van Jacobsen Compression is
used on the link. VJ compression is a means of reducing the standard TCP/IP header
from 40 octets to approximately 5 octets. This gives a significant performance
improvement, particularly when interactive applications are being used. For example,
when the user is typing, a single character can be passed over the link with a packet as
small as 5 octets as opposed to 40 octets when no JV compression is used. VJ
Compression has little effect on other types of links, such as ftp, where the packets are
much larger. The Framed Compression value will be used in preference to the VJ
Compression value set for a Line. The default is Off.
framed-ip
Used for User Service PPP or SLIP, sets the IP address of the remote user. Enter the
address in dot decimal notation as follows:
z
255.255.255.254 (default)—The IOLAN will use the Remote IP Address set in
the PPP settings for the line.
z
255.255.255.255—When the User Service is PPP, the IOLAN will allow the
remote machine to specify its IP address (overriding the Remote IP Address
configured in the line, PPP settings). When the User Service is SLIP, the IOLAN
will use the Remote IP Address set for the line (no negotiation).
z
n.n.n.n—(where n is a number) Enter the IP address of your choice. This IP
address will then be used in preference to the Remote IP Address set for a line.
framed-interface-id
Used for User Service PPP, sets the IPv6 address of the remote user.
framed-mtu
Used for User Service PPP or SLIP, specifies the maximum size of packets, in bytes,
being transferred across the link. On noisy links it might be preferable to fragment large
packets being transferred over the link, since there will be quicker recovery from errors.
Depending on whether you have selected a User Service of SLIP or PPP, details are as
follows:
z
PPP—Framed MTU will be the maximum size of packets that the IOLAN port will
accept. This value is negotiated between the two ends of the link. The valid range is
64-1500. The default value is 1500 bytes.
z
SLIP—Framed MTU will be the maximum size of packets being sent by the
IOLAN. The IOLAN will send SLIP packets in the range 256-1500 bytes. The
default value is 256 bytes.
The Framed MTU value will be used in preference to the MTU/MRU values set for a
Line.
User Commands 63
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
hotkey-prefix
The prefix that a user types to control the current session. The default value is hex 01,
which corresponds to Ctrl-a (^a) (hex value 02 would be Ctrl-b (^b), etc.):
z
^a number—To switch from one session to another, press ^a and then the required
session number. For example, ^a 2 would switch you to session 2. Pressing ^a 0
will return you to the IOLAN Menu.
z
z
z
z
^a n—Display the next session. The current session will remain active. The lowest
numbered active session will be displayed.
^a p—Display the previous session. The current session will remain active. The
highest numbered active session will be displayed.
^a m—To exit a session and return to the IOLAN. You will be returned to where
you left off. The session will be left running.
^a l—(Lowercase L) Locks the line until the user unlocks it. The user is prompted
for a password (any password, excluding spaces) and locks the line. Next, the user
must retype the password to unlock the line.
z
^r—When you switch from a session back to the Menu, the screen may not be
redrawn correctly. If this happens, use this command to redraw it properly. This is
always Ctrl R, regardless of the Hotkey Prefix.
The User Hotkey Prefix value overrides the Line Hotkey Prefix value. You can use the
Hotkey Prefix keys to lock a line only when the line Lock parameter is On.
idle-timer
The amount of time, in seconds, that the Idle Timer will run. Use this timer to close a
connection because of inactivity. When the Idle Timer expires, because there has been
no exchange of data within the specified time, the IOLAN will close the connection.
The default value is 0 (zero), meaning that the Idle Timer will not expire (the
connection is open permanently). The maximum value is 4294967 seconds. The User
Idle Timer will override the Line Idle Timer, with the exception of reverse SSH or
reverse Telnet sessions.
host-ip
For outbound User Services such as Telnet, Rlogin, or SSH, this is the target host name
or IP address. If no IP address is specified, the Host IP value in the Default User
configuration will be used. The default is 0.0.0.0. or None.
language
You can specify whether a user will use English or Customlang as the language that
appears in the Menu, CLI, or WebManager. The IOLAN supports one custom language
that must be downloaded to the IOLAN; otherwise, Customlang defaults to English.
level
The access that a user is allowed:
z
Admin—The admin level user has total access to the IOLAN. You can create more
than one admin user account but we recommend that you only have one. They can
monitor and configure the IOLAN.
z
Normal—The Normal level user has limited access to the IOLAN. Limited CLI
commands and Menu access are available with the ability to configure the user’s
own configuration settings.
z
z
Restricted—The Restricted level user can only access predefined sessions or
access the Easy Port Access menu.
Menu—The menu level user will only be able to access predefined session or
access the Easy Port Access menu. The Easy Port Access allows the user to
connect to the accessible line without disconnecting their initial connection to the
IOLAN. Does not have any access to CLI commands.
64
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
netmask
This is used for the PPP or SLIP Service types. Only used for IPv4. If the remote user
is on a subnet, enter the network’s subnet mask. For example, a subnet mask of
255.255.0.0.
password
The password the user will need to enter to login to the IOLAN. This case-sensitive
field accepts a maximum of 16 characters.
line-access
Specifies the user access rights to each IOLAN device line. Options are:
z
z
Read/Write—Users are given read and write access to the line.
Read In—Users are given access to read only outbound data, data that is going
from the IOLAN to the device.
z
Read Out—Users are given access to read only inbound data, data that is going
from the device to the IOLAN.
Users can read data going in both directions by selecting both the Read In and Read
Out options. The on|offoption is only for 1-port models. You can disable line access
in 2-port + models by specifying 0(zero).
phone-number
The phone number the IOLAN will dial to callback the user (you must have set
Callback to On). Enter the number without spaces. To change the phone number,
overwrite the previous entry; to clear the phone number, set it to "" (double quotes
without a space).
routing
Determines the routing mode used for RIP packets on the PPP and SLIP interfaces for
this user. Values are:
z
z
z
z
None—RIP packets are neither received nor sent by the IOLAN.
Send—RIP packets can only be sent by the IOLAN.
Listen—RIP packets can only be received by the IOLAN.
Send and Listen—RIP packets are sent and received by the IOLAN.
service
The type of service that the user will use.
sess-timer
The amount of time, in seconds, that the Session Timer will run. Use this timer to
forcibly close a user’s session (connection). When the Session Timer expires, the
IOLAN will end the connection. The default value is 0 (zero), meaning that the session
timer will not expire (the session is open permanently, or until the user logs out). The
maximum value is 4294967 seconds. The User Session Timer will override the Line
Session Timer, with the exception of reverse SSH or reverse Telnet sessions.
port
.For outbound User Services such as Telnet, SSH, TCP clear or SSL raw, this is the
target port number. The default value will change based on the type of Service selected;
the most common known port numbers are used as the default values.
access-clustered-ports
When enabled, allows the user access to IOLANs that have been configured in the
clustering group. The default is on.
User Commands 65
Download from Www.Somanuals.com. All Manuals Search And Download.
Configuring Users
Set User Session
of the options.
User Level Admin
set user .|<username>|* session 1|2|3|4|* [auto on|off]
[type off|telnet|rlogin|ssh]
Syntax
set user .|<username>|* session 1|2|3|4|* telnet-options
[host <config_host>] [port <TCP_port>]
[termtype <terminal_name>] [line-mode on|off]
[map-cr-crlf on|off] [local-echo on|off]
[echo <00-7f>] [eof <00-7f>] [erase <00-7f>] [intr <00-7f>]
[quit <00-7f>]
set user .|<username>|* session 1|2|3|4|* rlogin-options
[host <config_host>] [termtype <terminal_name>]
set user .|<username>|* session 1|2|3|4|*
ssh-options [host <config_host>] [port <TCP_port>]
[termtype <terminal_name>] [protocol ssh-1|ssh-2|ssh-2/1]
[compression on|off] [verbose on|off] [auto-login on|off]
[name <string>] [password <string>]
[ssh-1-cipher 3des|des|blowfish] [authentication rsa on|off]
[authentication password on|off]
[authentication keyboard-interactive on|off]
set user .|<username>|* session 1|2|3|4|* ssh-options
ssh-2-cipher-list <3des blowfish cast aes arcfour>
Show Default User
Description Shows the Default Users settings.
User Level Admin
show default user
Syntax
Show User
Description Shows user configuration settings.
User Level Admin
show user <configured_user>|.
Syntax
Options
<configured_user>
Show the settings for the specified user.
.
Show the settings for the current user.
66
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
Chapter
4
4
This chapter defines all the CLI commands associated with configuring the IOLAN’s line parameters.
1-Port vs. 2-Port+ Line Commands
If you are using a 1-port IOLAN, the admin user does not have the option of using the number or all
(*) options in the line commands, as there is only one line. In a 2-port+ IOLAN, the admin user must
specify . (current line), <number> (line number), or * (sets value for all lines) when configuring
lines.
Line Commands
Set Line
Description Configures line parameters. The set linecommand does not work on modem
ports/lines on models that have an internal modem.
User Level Normal, Admin
set line . [data-bits 5|6|7|8]
Syntax
[connection-method dial-in|dial-out|dial-in-out|direct-connect|
ms-direct-host|ms-direct-guest]
[idle-timer <0-4294967>] [line-name <name>]
[modem-name <config_modem>] [pages 1|2|3|4|5|6|7]
[parity none|even|odd|mark|space] [phone-number <phone_number>]
[rev-sess-security on|off] [sess-timer <0-4294967>]
[stop-bits 1|2|1.5] [termtype wyse60|vt100|ansi|dumb|tvi925|
ibm3151te|vt320|hp700|term1|term2|term3]
set line .|<number>|* ... [mode enabled|disabled] [break on|off]
[map-cr-crlf on|off] [data-logging on|off] [flowin on|off]
[flowout on|off] [hotkey-prefix <00-7f>] [initial cli|menu]
[keepalive on|off] [lock on|off]
AdminUser
Only
[microsoft-sac-support on|off] [motd on|off]
[multisessions <integer>] [reset on|off] [dial-timeout <number>]
[dial-retries <number>] [user <name>] [nouser]
[line-termination on|off] [internet-address <IPv4_address>]
Options
mode
Enables/disables a line (available only on 2-port+ models). The default is enabled.
data-bits
Specifies the number of bits in a byte. The default is 8.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
connection-method
Determines how a modem will work on the line. Select from the following options:
z
z
z
z
Direct Connect—Indicates that there is not a modem on the line. This is the
default.
Dial In—Specify this option when a user is remote and will be dialing in via
modem or ISDN TA.
Dial Out—Specify this option when a modem is attached to the serial port and is
being used to dial out.
Dial In/Out—Specify this option when the IOLAN is being used as a router
(depending on which end of the link your IOLAN is situated and how you want to
initiate the communication).
z
z
MS Direct-Host—Specify this option when the serial port is connected to a
Microsoft Guest device. Line Service must be set to PPP for this option.
MS Direct-Guest—Specify this option when the serial port is connected to a
Microsoft Host device. Line Service must be set to PPP for this option.
idle-timer
Enter a time period, in seconds, for which the Idle Timer will run. Use this timer to
close a connection because of inactivity. When the Idle Timer expires, the IOLAN will
end the connection. The maximum value is 4294967 seconds (about 49 days). The
default value of 0 (zero) means the Idle Timer will not expire, so the connection is
permanently open.
line-name
Provide a name for the line so it can be easily identified. The Remote Port Buffering
logging feature uses the Line Name when creating a file on the remote NFS server.
modem-name
The name of the predefined modem that is used on this line.
pages
For DSLogin line service, this is the number of video pages the terminal supports. Valid
values are 1-7. The default is 5 pages.
parity
Specifies if you are using Even, Odd, or No parity on the line. If you want to force a
parity type, you can specify Mark for 1or Space for 0.
phone-number
The phone number to use when Connection Method is set to Dial Out.
rev-sess-security
Enables/disables login/password authentication, locally or externally, on reverse Telnet
connections. The default is Off.
sess-time
Enter a time, in seconds, for which the Session Timer will run. Use this timer to
forcibly close the session (connection). When the Session Timer expires, the IOLAN
will end the connection. The default value is 0 seconds so the port will never timeout.
The maximum value is 4294967 seconds (about 49 days).
68
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
break
Specifies how a break is interpreted:
z
z
z
z
off—The IOLAN ignores the break key completely and it is not passed through to
the host. This is the default setting.
local—The IOLAN deals with the break locally. If the user is in a session, the
break key has the same effect as a hot key.
remote—When the break key is pressed, the IOLAN translates this into a telnet
break signal which it sends to the host machine.
break-interrupt—On some systems such as SunOS, XENIX, and AIX, a break
received from the peripheral is not passed to the client properly. If the client wishes
to make the break act like an interrupt key (for example, when the stty options
-ignbrkand brkintrare set).
map-cr-crlf
When Line Service Printer is selected, defines the default end-of-line terminator as
CR-LF (ASCII carriage-return line-feed) when enabled. Default is Off.
data-logging
When enabled, serial data will be buffered if the TCP connection is lost. When the TCP
connection is re-established, the buffered serial data will be sent to its destination (this
option is not available when Monitor DSR, Monitor DCD, or Multihost is enabled).
The data buffer is 4K for desktop models and 32K for rack mount and medical unit
models. If the data buffer is filled, incoming serial data will overwrite the oldest data.
The default is off.
flowin
Determines if input flow control is to be used. Default is On. This is active only when
Line Flow Control is set to Soft, Hard, or Both.
flowout
Determines if output flow control is to be used. Default is On. This is active only when
Line Flow Control is set to Soft, Hard, or Both.
hotkey-prefix
The prefix that a user types to lock a line or redraw the Menu. The default value is hex
01, which corresponds to Ctrl-a (^a) (hex value 02 would be Ctrl-b (^b), etc.):
z
^a l—(Lowercase L) Locks the line until the user unlocks it. The user is prompted
for a password (any password, excluding spaces) and locks the line. Next, the user
must retype the password to unlock the line.
z
^r—When you switch from a session back to the Menu, the screen may not be
redrawn correctly. If this happens, use this command to redraw it properly. This is
always Ctrl R, regardless of the Hotkey Prefix.
You can use the Hotkey Prefix key to lock a line only when the Line Lock parameter is
On.
initial
Specifies the initial interface a user navigates when logging into the line; either the
Menu or a prompt for the CLI. The default is CLI.
Line Commands 69
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
keepalive
Enables a per-connection TCP keepalive feature. After the configured number of
seconds, the connection will send a gratuitous ACK to the network peer, thus either
ensuring the connection stays active OR causing a dropped connection condition to be
recognized.
This parameter needs to be used in conjunction with server parameter,
monitor-connection-every. The interval determines how long the IOLAN will wait
during inactivity before "testing" the connection. It should be noted that if a network
connection is accidentally dropped, it can take as long as the specified interval before
anyone can reconnect to the serial port.
lock
When enabled, the user can lock his terminal with a password using the Hotkey Prefix
(default Ctrl-a) ^a l (lowercase L). The IOLAN prompts the user for a password and a
confirmation.
microsoft-sac-support
When enabled, the user can lock his terminal with a password using the Hotkey Prefix
(default Ctrl-a) ^a l (lowercase L). The IOLAN prompts the user for a password and a
confirmation.
motd
Enables/disables the message of the day on the line.
multisessions
This parameter defines the maximum number of additional reverse sessions which will
be allowed for this line allowing more control as to how the total reverse sessions are
allocated. This is on top of the main reverse session to the line.
The total number of reverse sessions on the IOLAN are dependent on the model:
z
z
z
z
1-port: 0-3
2-port: (4 x #-of-ports) -1
STS/SDS/MDC 4+ ports: (2 x #-of-ports) -1
SCS 4+ ports: (2 x (#-of-ports + 1)) -1
user
For DSLogin line service, makes this a line that is dedicated to the specified user. Only
this user will be able to log in on this line and they won’t need to enter their login name
- just their password. When the Line Service is set to Direct or Silent Rlogin, the User
parameter is used as the Rlogin user name (since Rlogin will not prompt you for a user
name).
nouser
Blanks out the User parameter, in case you want to change a dedicated user line to an
undedicated line.
reset
Resets the terminal type connected to the line when a user logs out.
dial-timeout
The number of seconds the IOLAN will wait to establish a connection to a remote
modem. The default value is 45 seconds.
dial-retries
The number of times the IOLAN will attempt to re-establish a connection with a remote
modem. The default value is 2.
70
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
stop-bits
Specifies the number of stop bits that follow a byte. The 1.5 option is only available on
the 1-port and 2-port models, but not on the modem of the SDS1M or SDS3M models.
term-type
Specifies the type of terminal connected to the line:
z
z
z
z
z
z
z
z
z
Dumb
WYSE60
VT100
ANSI
TVI925
IBM3151TE
VT320 (specifically supporting VT320-7)
HP700 (specifically supporting HP700/44)
Term1, Term2, Term3 (user-defined terminals)
line-termination
Used with EIA-422 and EIA-485 on SDS 8-port+ IOLAN models, specifies whether or
not the line requires termination. When termination is required, you need to terminate
the line at both ends of the connection.
internet-address
Used with reverse sessions, users can access serial devices connected to the IOLAN by
the specified Internet Address (or host name that can be resolved by a DNS). You must
reboot the IOLAN for the Internet Address to take affect (the kill line option does not
apply to this parameter). This parameter must be in IPv4 format.
Line Commands 71
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
Set Line Interface
The SCS, STS, and MDC IOLAN models support the EIA-232 interface only. Therefore, you do not
need to specify interface eia-232in the command syntax; you only need to specify the
command options (e.g., monitor-dcd).
Description Configures line interface (hardware) parameters.
User Level Admin
set line .|<number>|* interface eia-232 [monitor-dcd on|off]
[monitor-dsr on|off] [flow none|soft|hard|both]
Syntax
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|9600|
19200|38400|57600|115200|230400|28800|custom <baud_rate>]
set line .|<number>|* interface eia-422
[flow none|soft|hard|both]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|
custom <baud_rate>]]
set line .|<number>|* interface eia-485-half-duplex
[tx-driver-control auto|rts] [flow none|soft]
[echo-suppression on|off]]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]
set line .|<number>|* interface eia-485-full-duplex
[tx-driver-control auto|rts] [flow none|soft]
[speed 50|75|110|134|150|200|300|600|1200|1800|2400|4800|
9600|19200|38400|57600|115200|230400|28800|custom <baud_rate>]
Options
eia-232 | eia-422 | eia-485-half-duplex|eia-485-full-duplex
Specifies the type of serial line that is being used with the IOLAN. Specify either
EIA-232, EIA-422, EIA-485-half-duplex, or EIA-485-full-duplex. The STS, SCS, and
MDC models support only EIA-232.
monitor-dcd
Specifies whether the RS-232 signal DCD (Data Carrier Detect) should be monitored.
This is used with modems or any other device that sends a DCD signal. When it is
monitored and the IOLAN detects a DCD signal, the line service is started. Default is
Off. If both Monitor DCD and Monitor DSR are enabled, both signals must be detected
before the line service is started.
monitor-dsr
Specifies whether the RS-232 signal DSR (data set ready) should be monitored. This is
used with modems or any device that sends a DSR signal. When it is monitored and the
IOLAN detects a DSR signal, the line service is started. Default is Off. The Monitor
DSR parameter is not available for medical unit models. If both Monitor DCD and
Monitor DSR are enabled, both signals must be detected before the line service is
started.
flow
Defines whether the data flow is handled by the software (Soft), hardware (Hard),
Both, or None. If you are using SLIP, set to Hard only. If you are using PPP, set to
either Soft or Hard (Hard is recommended). If you select Soft with PPP, you must set
the ACCM parameter when you configure PPP for the Line.
72
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
tx-driver-control
Used with a EIA-485 serial interface, if your application supports RTS (Request To
Send), select this option. Otherwise, select Auto. Default is Auto.
duplex
Specify whether the line is Full Duplex (communication both ways at the same time) or
Half Duplex (communication in one direction at a time).
echo-suppression
This parameter applies only to EIA-485 Half Duplex mode. All characters will be
echoed to the user and transmitted across the serial ports. Some EIA-485 applications
require local echo to be enabled in order to monitor the loopback data to determine that
line contention has occurred. If your application cannot handle loopback data, echo
suppression should be On. The default is echo suppression Off.
speed
Specifies the baud rate of the line; keep in mind that speed is affected by the length of
the cable. You can also specify a custom baud rate; valid values are 50 - 1843200.
Set Line Service
SSL/TLS can be enabled for the following Line Services: DSLogin, Raw, Bidir,
VModem, Server Tunnel, Client Tunnel, Modbus Master, Custom App, and TruePort.
User Level Admin
Line Commands 73
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
set line .|<number>|* service bidir <config_host> <server_port>
<host_port>
Syntax
set line .|<number>|* service direct|silent rlogin <config_host>
set line .|<number>|* service direct raw <config_host>
<host_port>
set line .|<number>|* service silent raw <config_host>
<host_port>
[multihost all|backup <config_backup_host> <host_port>|none]
set line .|<number>|* service direct|silent telnet|ssh
<config_host> [<host_port>]
set line .|<number>|* service reverse raw [multihost on|off]|
ssh|telnet <server_port>
set line .|<number>|* service client-tunnel <config_host>
<host_port>
set line .|<number>|* service server-tunnel <server_port>
set line .|<number>|* service dslogin|printer|ppp|slip|udp|
vmodem|modbus-master|modbus-slave|custom-app|power-management
set line .|<number>|* service trueport client-initiated off
<config_host> <host_port> [signal-active on|off]
[multihost all|backup <config_backup_host> <host_port>|none]
set line .|<number>|* service trueport client-initiated on
<server_port> [signal-active on|off] [multihost on|off]
Options
bidir
This service allows the IOLAN listen for incoming TCP connection and if needed,
initiate a TCP connection.
<config_host>
The name of the target host. The host must exist in the IOLAN host table.
<server_port>
The IOLAN port number.
<host_port>
The port number the target host is listening on for incoming connections.
direct
Direct connections bypass the IOLAN, enabling the user to log straight into a specific
host. A direct connection is recommended where a user logging in to the IOLAN is not
required. It is also recommended where multiple sessions are not a requirement. The
message Press return to continueis displayed on the users screen. The user
must press a key to display the host login prompt. The message is redisplayed on
logout.
silent
Silent connections are the same as direct connections, except they are permanently
established. The host login prompt is displayed on the screen. Logging out redisplays
this prompt. Silent connections, unlike direct connections, however, make permanent
use of pseudo tty resources and therefore consume host resources even when not in use.
74
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
rlogin
Sets the line for a remote login connection.
raw
Creates a connection where no authentication takes place and data is passed unchanged.
telnet
Sets the line for a telnet connection.
ssh
Sets the line for an SSH connection.
reverse
Enables a TCP/IP host to establish a login connection on an external machine attached
to a port. For example, to access machines like protocol converters, statistical
multiplexors, or machines like routers, firewalls, servers, etc.
client-tunnel
Sets the line for a client tunnel connection.
dslogin
The default connection. The IOLAN displays a login on that line. For example,
DSLogin is used when a System Administrator configures the IOLAN, providing
authentication of a user before starting a User Service of SLIP, or users starts a
session(s) from the IOLAN to hosts.
printer
Using the IOLAN as a printer server. For example, remote printing using LPD (port
515) or RCP (port 514).
ppp
Sets the port to a dedicated PPP line.
slip
Sets the port in SLIP mode.
udp
Sets the line to listen for and/or send UDP data.
vmodem
The IOLAN port behaves as if it were a modem to the attached device.
server-tunnel
Sets the line for a server tunnel connection.
modbus-master
Sets the line to act as a Modbus master.
custom-app
Sets the line to use the custom application created with the SDK.
power-management
Indicates that there is a power bar connection to this serial line.
trueport
Sets the line to communicate with the TruePort utility. You must install the TruePort
utility on the host machine.
Line Commands 75
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
client-initiated
When this option is turned on, the IOLAN will wait for a connection from the TruePort
host (see the TruePort documentation for information on how to set up this feature on
the TruePort host). When this option is turned off, the IOLAN will initiate the
connection to the TruePort host. The default is off.
signal-active
This option has the following impact based on the state of the TruePort connection:
z
TruePort Lite Mode—When enabled, the EIA-232 signals remain active before,
during, and after the TruePort connection is established. When disabled, the
EIA-232 signals remain inactive when there is no TruePort connection and active
when there is a TruePort connection.
z
TruePort Full Mode—When enabled, the EIA-232 signals remain active before
and after the TruePort connection and the TruePort client will control the state of
the signals during the established TruePort connection. When disabled, the
EIA-232 signals remain inactive before and after the TruePort connection and the
TruePort client will control the state of the signals during the established TruePort
connection.
Default: Enabled
multihost
Used for connections coming from the network to the serial port for TruePort or Raw
services, allows multiple hosts to connect to the serial device.
multihost all|backup <config_backup_host> <tcp_port>|none
Used for connections going from the serial port to the network for TruePort or Silent
Raw services, allows the serial device to communicate to either all the hosts in the
multihost list or a primary/backup host schema (see Configuring Multiple Hosts in the
IOLAN User’s Guide for a more detailed explanation).
Set Modem
Description Sets the modem initialization strings for a defined modem. If you wish to add a new
modem, use the add modemcommand.
User Level Admin
set modem <modem_name> <init_string>
Syntax
Options
<modem_name>
Predefined modem name.
<init_string>
Specify the initialization string for the modem. This can be up to 60 characters long, but
cannot include spaces.
Set Termtype
Description Sets the terminal type for the current terminal session. term1, term2, and term3 refer to
the user-uploadable custom terminal definitions. If these are not present, the default is
wyse60.
User Level Restricted, Normal, Admin
set termtype
Syntax
[wyse60|vt100|ansi|dumb|tvi925|ibm3151te|vt320|hp700|term1|term2
|term3]
76
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Commands
Option
wyse60|vt100|ansi|dumb|tvi925|ibm3151te|vt320|hp700|term1|term2|term3
Specifies the type of terminal connected to the line:
z
z
z
z
z
z
z
z
z
Dumb
WYSE60
VT100
ANSI
TVI925
IBM3151TE
VT320 (specifically supporting VT320-7)
HP700 (specifically supporting HP700/44)
Term1, Term2, Term3 (user-defined terminals)
Show Line
Description Shows the line settings/information.
User Level Admin
show line <number>|*
Syntax
Line Commands 77
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Line Service Commands
Set Custom-App
Description You can create a custom application that can run on a specific serial line in IOLAN
using the Perle SDK.
User Level Admin
set custom-app line .|<number>|* program-command-line <command>
Syntax
Options
program-command-line
The name of the SDK program executable that has been already been downloaded to
the IOLAN, plus any parameters you want to pass to the program. Maximum of 80
characters. Use the shellCLI command as described in the SDK Programmer’s Guide
to manage the files that you have downloaded to the IOLAN. For example, using
sample outrawprogram, you would type:
outraw -s 0 192.168.2.1:10001 Acct:10001
if you were starting the application on the Server (notice the -s 0parameter specifies
Line 1).
Set Rlogin-Client
Description Configures the Rlogin parameters for the specified line. When the IOLAN initiates an
rlogin connection to a host, it is acting as a rlogin client.
User Level Normal, Admin
set rlogin-client line .|<number>|* termtype <terminal_name>
Syntax
Option
termtype
Type of terminal attached to this line; for example, ansi or wyse60.
Set Telnet-Client
Description Configures the Telnet parameters for the specified line. When the IOLAN initiates a
Telnet connection to a host, it is acting as a Telnet client.
User Level Normal, Admin
set telnet-client line .|<number>|* [termtype <terminal_name>]
[line-mode on|off] [map-cr-crlf on|off] [local-echo on|off]
[echo <00-7f>] [eof <00-7f>] [erase <00-7f>] [intr <00-7f>]
[quit <00-7f>] [escape <00-7f]
Syntax
Options
termtype
Type of terminal attached to this line; for example, ANSI or WYSE60.
line-mode
When On, keyboard input is not sent to the remote host until Enter is pressed,
otherwise input is sent every time a key is pressed. Default is Off.
map-cr-crlf
Maps carriage returns (CR) to carriage return line feed (CRLF). The default value is
Off.
local-echo
Toggles between local echo of entered characters and suppressing local echo. Local
echo is used for normal processing, while suppressing the echo is convenient for
entering text that should not be displayed on the screen, such as passwords. This
parameter can only be used when Line Mode is On. Default is Off.
78
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
echo
Defines the echo character. When Line Mode is On, typing the echo character echoes
the text locally and sends only completed lines to the host. This value is in hexadecimal
with a default value of 5 (ASCII value ^E).
eof
Defines the end-of-file character. When Line Mode is On, entering the EOF character
as the first character on a line sends the character to the remote host. This value is in
hexadecimal with a default value of 4 (ASCII value ^D).
erase
Defines the erase character. When Line Mode is Off, typing the erase character erases
one character. This value is in hexadecimal with a default value of 8 (ASCII value ^H).
intr
Defines the interrupt character. Typing the interrupt character interrupts the current
process. This value is in hexadecimal with a default value of 3 (ASCII value ^C).
quit
Defines the quit character. Typing the quit character closes and exits the current telnet
session. This value is in hexadecimal with a default value of 1c (ASCII value FS).
escape
Defines the escape character. Returns you to the command line mode. This value is in
hexadecimal with a default value of 1d (ASCII value GS).
Set SSH-Client
Description Configures the SSH parameters for the specified line. When the IOLAN initiates a SSH
connection to a host, it is acting as a SSH client.
User Level Normal, Admin
set ssh-client line .|<number>|* [termtype <terminal_name>]
[protocol ssh-1|ssh-2|ssh-2/1] [compression on|off]
[verbose on|off] [auto-login on|off] [name <string>]
[password <string>] [ssh-1-cipher 3des|des|blowfish]
[authentication rsa on|off] [authentication dsa on|off]
[authentication keyboard-interactive on|off]
Syntax
set ssh-client line .|<number>|*
ssh-2-cipher-list <3des blowfish cast aes arcfour>
Options
termtype
Type of terminal attached to this line; for example, ANSI or WYSE60.
protocol
Specify the SSH protocol you want to use for the connection, SSH-1, SSH-2, or either,
SSH2/1.
compression
Requests compression of all data. Compression is desirable on modem lines and other
slow connections, but will only slow down things on fast networks.
verbose
Displays debug messages on the terminal.
Line Commands 79
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
auto-login
Creates an automatic SSH login, using the Name and Password values.
name
The user’s name when Auto Login is enabled.
password
The user’s password when Auto Login is enabled.
ssh-1-cipher
Select the encryption method (cipher) that you want to use for your SSH version 1
connection:
z
z
3DES
Blowfish
ssh-2-cipher-list
Select the order of negotiation for the encryption method (ciphers) that the IOLAN will
use for the SSH version 2 connection:
z
z
z
z
z
3DES
Blowfish
AES
Arcfour
CAST
authentication rsa
An authentication method used by SSH version 1 and 2. When enabled, an SSH client
session will try to authenticate via RSA.
authentication dsa
An authentication method used by SSH version 2. When enabled, an SSH client session
will try to authenticate via DSA.
authentication keyboard-interactive
The user types in a password for authentication.Used for SSH2 only.
80
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set PPP
Description Configures the Lines PPP settings.
User Level Admin
set ppp wireless-wan|line .|<number>|* [accm <8_hex_digits>]
[address-comp on|off] [auth-tmout <integer>]
Syntax
[challenge-interval <integer>] [cr-retry <integer>]
[cr-timeout <integer>] [ipaddr-neg on|off]
[ipv6-global-network-address <IPv6_network_prefix>]
[ipv6-local-interface <interface_id>]
[ipv6-remote-interface <interface_id>]
[lipaddr <IPV4_address>] [magic-neg on|off] [mru <64-1500>]
[nak-retry <integer>] [netmask <IPV4_address>]
[password <string>] [proto-comp on|off] [ripaddr <IPV4_address>]
[roaming-callback on|off] [authentication none|pap|chap]
[routing none|send|listen|send-and-listen] [rpassword <string>]
[ruser <string>] [tr-retry <integer>] [tr-tmout <integer>]
[user <string>] [vj-comp on|off]
Options
accm
Specifies the ACCM (Asynchronous Control Character Map) characters that should be
escaped from the data stream. This is entered as a 32-bit hexadecimal number with each
bit specifying whether or not the corresponding character should be escaped. The bits
are specified as the most significant bit first and are numbered 31-0. Thus if bit 17 is
set, the 17th character should be escaped, that is, 0x11 (XON). So entering the value
000a0000 will cause the control characters 0x11 (XON) and 0x13 (XOFF) to be
escaped on the link, thus allowing the use of XON/XOFF (software) flow control. If
you have selected Soft Flow Control on the Line, you must enter a value of at least
000a0000 for the ACCM. The default value is 00000000, which means no characters
will be escaped.
address-comp
This determines whether compression of the PPP Address and Control fields take
place on the link. The default is On. For most applications this should be enabled.
auth-tmout
The timeout, in minutes, during which successful PAP or CHAP authentication must
take place (when PAP or CHAP is turned On). If the timer expires before the remote
end has been authenticated successfully, the link will be terminated.
challenge-interval
The interval, in minutes, for which the IOLAN will issue a CHAP re-challenge to the
remote end. During CHAP authentication, an initial CHAP challenge takes place, and is
unrelated to CHAP re-challenges. The initial challenge takes place even if re-challenges
are disabled. Some PPP client software does not work with CHAP re-challenges, so you
might want to leave the parameter disabled in the IOLAN. The default value is 0 (zero),
meaning CHAP re-challenge is disabled.
cr-retry
The maximum number of times a configure requestpacket will be re-sent before
the link is terminated.
cr-timeout
The maximum time, in seconds, that LCP (Link Control Protocol) will wait before it
considers a configure requestpacket to have been lost.
Line Commands 81
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
ipaddr-neg
Specifies whether or not IP address negotiation will take place. IP address negotiation is
where the IOLAN allows the remote end to specify its IP address. The default value is
Off. When On, the IP address specified by the remote end will be used in preference to
the Remote IP Address set for a Line. When Off, the Remote IP Address set for the
Line will be used.
ipv6-global-network-prefix
You can optionally specify an IPv6 global network prefix that the IOLAN will advertise
to the device at the other end of the PPP link. Enter the IPv6 network prefix in the
aaaa:bbbb:cccc:dddd::format.
ipv6-local-interface
The local IPv6 interface identifier of the IOLAN end of the PPP link. For routing to
work, you must enter a local IP address. Choose an address that is part of the same
network or subnetwork as the remote end. Do not use the IOLAN’s (main) IP address in
this field; if you do so, routing will not take place correctly. The first 64 bits of the
Interface Identifier must be zero, therefore, ::abcd:abcd:abcd:abcd is the expected
format.
ipv6-remote-interface
The remote IPv6 interface identifier of the remote end of the PPP link. Choose an
address that is part of the same network or subnetwork as the IOLAN. If you set the
PPP parameter IP Address Negotiation to On, the IOLAN will ignore the remote IP
address value you enter here and will allow the remote end to specify its IP address. If
your user is authenticated by RADIUS and the RADIUS parameter
Framed-Interface-ID is set in the RADIUS file, the IOLAN will use the value in the
RADIUS file in preference to the value configured here. The first 64 bits of the
Interface Identifier must be zero, therefore, ::abcd:abcd:abcd:abcd is the expected
format.
lipaddr
The IPV4 IP address of the IOLAN end of the PPP link. For routing to work, you must
enter a local IP address. Choose an address that is part of the same network or
subnetwork as the remote end; for example, if the remote end is address
192.101.34.146, your local IP address can be 192.101.34.145. Do not use the IOLAN’s
(main) IP address in this field; if you do so, routing will not take place correctly.
magic-neg
Determines if a line is looping back. If enabled (On), random numbers are sent on the
link. The random numbers should be different, unless the link loops back. The default is
Off.
mru
The Maximum Receive Unit (MRU) parameter specifies the maximum size of PPP
packets that the IOLAN’s port will accept. Enter a value between 64 and 1500 bytes; for
example, 512. The default value is 1500. If your user is authenticated by the IOLAN,
the MRU value will be overridden if you have set a Framed MTU value for the user. If
your user is authenticated by RADIUS and the RADIUS parameter Framed-MTU is set
in the RADIUS file, the IOLAN will use the value in the RADIUS file in preference to
the value configured here.
nak-retry
The maximum number of times a configure NAKpacket will be re-sent before the
link is terminated.
82
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
netmask
The network subnet mask. For example, 255.255.0.0. If your user is authenticated by
RADIUS and the RADIUS parameter Framed-Netmask is set in the RADIUS file, the
IOLAN will use the value in the RADIUS file in preference to the value configured
here.
password
This field defines the password which is associated with the user defined by the user
parameter. It is used to authenticate a user connecting to the IOLAN. You can enter a
maximum of 16 alphanumeric characters.
proto-comp
This determines whether compression of the PPP Protocol field takes place on this link.
The default is On.
ripaddr
The IPV4 IP address of the remote end of the PPP link. Choose an address that is part
of the same network or subnetwork as the IOLAN. If you set the PPP parameter IP
Address Negotiation to On, the IOLAN will ignore the remote IP address value you
enter here and will allow the remote end to specify its IP address. If your user is
authenticated by RADIUS and the RADIUS parameter Framed-Address is set in the
RADIUS file, the IOLAN will use the value in the RADIUS file in preference to the
value configured here. The exception to this rule is a Framed-Address value in the
RADIUS file of 255.255.255.254; this value allows the IOLAN to use the remote IP
address value configured here.
roaming-callback
A user can enter a telephone number that the IOLAN will use to callback him/her. This
feature is particularly useful for a mobile user. Roaming callback can only work when
the User Callback parameter is set to On. Roaming callback therefore overrides (fixed)
User Callback.To use Roaming Callback, the remote end must be a Microsoft
Windows OS that supports Microsoft’s Callback Control Protocol (CBCP). The user is
allowed 30 seconds to enter a telephone number after which the IOLAN ends the call.
The default is Off.
routing
Determines the routing mode (RIP, Routing Information Protocol) used on the PPP
interface as one of the following options:
z
z
z
z
None—Disables RIP over the PPP interface.
Send—Sends RIP over the PPP interface.
Listen—Listens for RIP over the PPP interface.
Send and Listen—Sends RIP and listens for RIP over the PPP interface.
This is the same function as the Framed-Routing attribute for RADIUS authenticated
users. Default is None.
rpassword
The rpassword is the password which is associated with the user defined by ruser. It
is used to authenticate a user connecting to the IOLAN. You can enter a maximum of
16 alphanumeric characters.
Line Commands 83
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
ruser
This field is used to authenticate a user connecting to this line. It is used in conjunction
with the rpassword field. By specifying a name here, this line becomes dedicated to
that user only. If left blank, the internal user database will be used to authenticate the
connection and any user configured will be able to access this line. You can enter a
maximum of sixteen alphanumeric characters.
This option does not work with external authentication.
authentication
The type of authentication that will be done on the link: None, PAP, or CHAP. The
default is CHAP. You can use PAP or CHAP to authenticate a port or user on the
IOLAN, from a remote location, or authenticate a remote client/device, from the
IOLAN (not commonly used for Dial Out).
PAP is a one time challenge of a client/device requiring that it respond with a valid
username and password. A timer operates during which successful authentication must
take place. If the timer expires before the remote end has been authenticated
successfully, the link will be terminated.
CHAP challenges a client/device at regular intervals to validate itself with a username
and a response, based on a hash of the secret (password). A timer operates during which
successful authentication must take place. If the timer expires before the remote end has
been authenticated successfully, the link will be terminated.
When setting either PAP and CHAP, make sure the IOLAN and the remote client/device
have the same setting. For example, if the IOLAN is set to PAP, but the remote end is
set to CHAP, the connection will be refused.
tr-retry
The maximum number of times a terminate requestpacket will be re-sent before
the link is terminated.
tr-tmout
The maximum time, in seconds, that LCP (Link Control Protocol) will wait before it
considers a terminate requestpacket to have been lost.
user
This field is used by a remote peer to authenticate a PPP connection on this line. It is
used in conjunction with the password field. You can enter a maximum of sixteen
alphanumeric characters.
vj-comp
This determines whether Van Jacobson Compression is used on this link. The default is
On. If your user is authenticated by the IOLAN, this VJ compression value will be
overridden if you have set the User Framed Compression On. If your user is
authenticated by RADIUS and the RADIUS parameter Framed-Compression is set in
the RADIUS file, the IOLAN will use the value in the RADIUS file in preference to the
value configured here.
84
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set PPP Dynamic-DNS
Description This option is only available when IP address negotiation (ipaddr-neg) is on. When
enabled, the IOLAN will automatically update the DNS server with the specified host
name and negotiated IP address for the PPP session.
User Level Admin
set ppp line .|<number>|* dynamic-dns [on|off]
[hostname <hostname>] [username <username>]
[password <password>]
Syntax
Options
hostname
Specify the host name that will be updated with the PPP session’s IP address on the
DynDNS.org server.
username
Specify the user name used to access the DynDNS.org server.
password
Specify the password used to access the DynDNS.org server.
Set SLIP
Description Configures the lines SLIP settings.
User Level Admin
set slip line .|<number>|* [lipaddr <IPV4_address>]
Syntax
[mtu <256-1006>] [netmask <IPV4_address>]
[ripaddr <IPV4_address>] [vj-comp on|off]
[routing none|send|listen|send-and-listen]
Options
lipaddr
The IPv4 address of the IOLAN end of the SLIP link. For routing to work you must
enter an IP address in this field. Choose an address that is part of the same network or
subnetwork as the remote end; for example, if the remote end is address
192.101.34.146, your local IP address can be 192.101.34.145. Do not use the IOLAN’s
(main) IP address in this field; if you do so, routing will not take place correctly.
mtu
The Maximum Transmission Unit (MTU) parameter restricts the size of individual
SLIP packets being sent by the IOLAN. Enter a value between 256 and 1500. The
default value is 256. If your user is authenticated by the IOLAN, this MTU value will
be overridden when you have set a Framed MTU value for the user. If your user is
authenticated by RADIUS and the RADIUS parameter Framed-MTU is set in the
RADIUS file, the IOLAN will use the value in the RADIUS file in preference to the
value configured here.
netmask
The network subnet mask. For example, 255.255.0.0. If your user is authenticated by
RADIUS and the RADIUS parameter Framed-Netmask is set in the RADIUS file, the
IOLAN will use the value in the RADIUS file in preference to the value configured
here.
Line Commands 85
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
ripaddr
The IPv4 address of the remote end of the SLIP link. Choose an address that is part of
the same network or subnetwork as the IOLAN. If your user is authenticated by the
IOLAN, this remote IP address will be overridden if you have set a Framed IP Address
for the user. If your user is authenticated by RADIUS and the RADIUS parameter
Framed-Address is set in the RADIUS file, the IOLAN will use the value in the
RADIUS file in preference to the value configured here.
vj-comp
This determines whether Van Jacobson compression is used on this link; that is, whether
you are using SLIP or C-SLIP (compressed SLIP). The choices are On (C-SLIP) or Off
(SLIP). The default is On. C-SLIP greatly improves the performance of interactive
traffic, such as Telnet or Rlogin.
If your user is authenticated by the IOLAN, this VJ compression value will be
overridden if you have set a Framed Compression value for a user. If your user is
authenticated by RADIUS and the RADIUS parameter Framed-Compression is set in
the RADIUS file, the IOLAN will use the value in the RADIUS file in preference to the
value configured here.
routing
Determines the routing mode (RIP, Routing Information Protocol) used on the SLIP
interface as one of the following options:
z
z
z
z
None—Disables RIP over the SLIP interface.
Send—Sends RIP over the SLIP interface.
Listen—Listens for RIP over the SLIP interface.
Send and Listen—Sends RIP and listens for RIP over the SLIP interface.
This is the same function as the Framed-Routing attribute for RADIUS authenticated
users. Default is None.
Set UDP
Description Configures the UDP settings for the serial line.
User Level Normal, Admin
set udp line .|<number>|* entry 1|2|3|4
both auto-learn|specific <UDP_port> [<start_IP_address>]
[<end_IP_address>]
Syntax
set udp line .|<number>|* entry 1|2|3|4 in
any-port|auto-learn|specific <UDP_port> [<start_IP_address>]
[<end_IP_address>]
set udp line .|<number>|* entry 1|2|3|4 out <UDP_port>
[<start_IP_address>] [<end_IP_address>]
set udp line .|<number>|* entry 1|2|3|4 none
Options
entry 1|2|3|4
Selects which of the 4 available entries we wish to define/modify. For each entry the
user can specify a different IP address range, UDP port and direction of data flow.
86
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
both|in|out|none
The direction in which information is received or relayed:
z
z
None—UDP service not enabled.
In—LAN to serial. The IOLAN will listen on port value configured in the DS Port
parameter for messages coming from the learned or configured port.
z
z
Out—Serial to LAN. The IOLAN will forward data received on the serial port to
the IP address range, UDP port configured for this entry.
Both—Messages are relayed in both directions. For messages coming from the
LAN to the serial device, IOLAN will listen on the port value configured in the DS
Port parameter for messages coming from the learned or configured port. For
messages going from the serial device to the LAN, the IOLAN will forward the
data to the IP address range and UDP port configured for this entry. If auto-learn
is enabled, the IOLAN must receive a UDP message before it can send one, since
the UDP port number is learned from the received message.
auto-learn
The IOLAN will only listen to the first port that it receives a UDP packet from.
Applicable when set to In or Both.
any-port
The IOLAN will receive messages from any port sending UDP packets. Applicable
when set to In.
specific
The port that the IOLAN will use to relay messages to servers/hosts or the port from
which the IOLAN will receive messages to be forwarded to the serial port.. This option
works with any setting except None. The IOLAN will listen for UDP packets on the
port configured by the DS Port parameter.
<start_IP_address>
The first host IP address in the range of IP addresses (for IPV4 or IPV6) that the
IOLAN will listen for messages from and/or send messages to.
<end_IP_address>
The last host IP address in the range of IP addresses (for IPV4, not required for IPV6)
that the IOLAN will listen for messages from and/or send messages to.
Set Vmodem
Description Configures the vmodem settings for the serial line. SSL/TLS can be enabled and
configured for this Line Service.
User Level Admin
set vmodem line .|<number>|* [echo on|off]
[failure-string <string>] [host <config_host>]
[init-string <string>] [mode auto|manual]
[port <TCP_port>|0] [respons-delay <time_ms>]
[signals dcd always-high|follow-connection]
[signals dtr always-high|represent-dcd|represent-ri]
[signals rts always-high|represent-dcd|represent-ri]
[style numeric|verbose] [success-string <string>]
[suppress on|off]
Syntax
Options
echo
When enabled, echoes back characters that are typed in (equivalent to ATE0/ATE1
commands). Disabled by default.
Line Commands 87
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
failure-string
String that is sent to the serial device when a connection fails. If no string is entered,
then the string NO CARRIERwill be sent.
host
The target host name.
init-string
You can specify additional vmodem commands that will affect how vmodem starts. The
following commands are supported: ATQn, ATVn, ATEn, ATS0, AT&Z1, AT&Sn,
AT&Rn, AT&Cn, AT&F, ATS2, ATS12, and ATDS1.
See VModem Initialisation Commands in the IOLAN User’s Guide for a more detailed
explanation of the support initialisation commands.
mode
Auto mode establishes the connection when the line becomes active. You must supply
phone number.
port
The port number the target host is listening on for messages.
response-delay
The amount of time, in milliseconds, before an AT response is sent to the requesting
device. The default is 250 ms.
signals dcd
Controls the state of the DCD signal.
z
z
always-high = DCD signal will always stay high.
follow-connection = DCD signal will be high when an end to end connection is
established and low when it is not.
Since the IOLAN does not have a physical DCD pin, you need to re-map the DTR or
RTS signal to DCD to have the signal present. (see next option).
signals dtr
You can specify how the DTR signal pin acts during your modem application
connection, as itself (DTR), as DCD, or as RI.
signals rts
You can specify how the RTS signal pin acts during your modem application
connection, as itself (RTS), as DCD, or as RI.
88
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
style
One of the following:
z
z
Verbose—Return codes (strings) are sent to the connected device.
Numeric—The following characters can be sent to the connected device:
0 OK
1 CONNECTED
2 RING
3 NO CARRIER
4 ERROR
6 ITERFACE DOWN
7 CONNECTION REFUSED
8 NO LISTNER
success-string
String that is sent to the serial device when a connection succeeds. If no string is
entered, then the string CONNECTwill be sent with the connecting speed, for example
CONNECT 9600.
suppress
When enabled, the connection success/failure indication strings are sent to the
connected device, otherwise these indications are suppressed. The default is disabled.
Line Commands 89
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set Vmodem-Phone
Description This command associates a phone number with an IP address and TCP port. This
enables the existing modem application to issue a dial command with a phone number.
The phone number will be searched for in this table and if an exact match is found, the
associated IP address and TCP port will be used to establish the connection. This is a
universal command, meaning that all VModem lines will have access to the entries
defined here. 1-port models support up to 4 entries, all other desktop models support up
to 8 entries, and rack mount and medical unit models support up to 48 entries.
User Level Admin
set vmodem-phone entry <number> phone-number <string>
<IP_address> <TCP_port>
Syntax
set vmodem-phone entry <number> delete
entry
Options
Specify the entry number in the vmodem phone number table.
phone-number
Specify the phone number that your application uses to connect to remote location.
Enter the number exactly as it is issued by your application.
<IP_address>
Specify the IP address of the remote host that is receiving the vmodem connection.
<TCP_port>
Specify the TCP port that the remote host is lisening on for the vmodem connection
delete
Deletes the specified entry from the phone number table.
Set SSL Line
Description Sets the SSL/TLS parameters for the line. SSL/TLS can be enabled for the following
Line Services: DSLogin, Raw, Bidir, VModem, Server Tunnel, Client Tunnel, Modbus
Master, Custom App and Trueport.
User Level Admin
set ssl line .|<number>|* [enable on|off] [use-server on|off]
[version any|tslv1|sslv3] [type client|server]
[verify-peer on|off] [validation-criteria
Syntax
country <code>|state-province <text>|locality <text>
|organisation <text>|organisation-unit <text>
|common-name <text>|email <email_addr>]
Options
enable
Activates the SSL/TLS settings for the line.
use-server
Uses the SSL/TLS server configuration for the line.
version
Specify whether you want to use:
z
Any—The IOLAN will try a TLSv1 connection first. If that fails, it will try an
SSLv3 connection. If that fails, it will try an SSLv2 connection.
z
z
TLSv1—The connection will use only TLSv1.
SSLv3—The connection will use only SSLv3.
The default is Any.
90
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
type
Specify whether the IOLAN will act as an SSL/TLS client or server. The default is
Client.
verify-peer
Enable this option when you want the Validation Criteria to match the Peer Certificate
for authentication to pass. If you enable this option, you need to download an SSL/TLS
certificate authority (CA) list file to the IOLAN.
validation-criteria
Any values that are entered in the validation criteria must match the peer certificate for
an SSL connection; any fields left blank will not be validated against the peer
certificate.
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the peer SSL/TLS certificate.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the peer SSL/TLS certificate.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the peer SSL/TLS
certificate.
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the peer SSL/TLS certificate.
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the peer
SSL/TLS certificate.
Line Commands 91
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set SSL Line Cipher-suite
Description Sets the SSL/TLS cipher suite parameters for the line.
User Level Admin
set ssl line .|<number>|* cipher-suite
Syntax
option1|option2|option3|option4|option5
encryption any|aes|3des|des|arcfour|arctwo|none
min-key-size 40|56|64|128|168|256
max-key-size 40|56|64|128|168|256
key-exchange any|rsa|edh-rsa|edh-dss|adh
hmac any|sha1|md5
Options
option1|option2|option3|option4|option5
Sets the priority of the cipher suite, with option1being highest priority and option5
lowest priority.
encryption
Select the type of encryption that will be used for the SSL connection:
z
z
z
z
z
z
z
Any—Will use the first encryption format that can be negotiated.
AES
3DES
DES
ARCFOUR
ARCTWO
None—Removes any values defined for the cipher option.
The default value is Any.
min-key-size
The minimum key size value that will be used for the specified encryption type. The
default is 40.
max-key-size
The maximum key size value that will be used for the specified encryption type. The
default is 256.
key-exchange
The type of key to exchange for the encryption format:
z
Any—Any key exchange that is valid is used (this does not, however, include ADH
keys).
z
z
z
z
RSA—This is an RSA key exchange using an RSA key and certificate.
EDH-RSA—This is an EDH key exchange using an RSA key and certificate.
EDH-DSS—This is an EDH key exchange using a DSA key and certificate.
ADH—This is an anonymous key exchange which does not require a private key
or certificate. Choose this key if you do not want to authenticate the peer device,
but you want the data encrypted on the SSL/TLS connection.
The default is Any.
hmac
Select the key-hashing for message authentication method for your encryption type:
z
z
z
Any
MD5
SHA1
The default is Any.
92
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set Modbus-Slave Line
Description Sets the Modbus slave parameters for the line.
User Level Admin
set modbus-slave line .|<number>|* [crlf on|off]
[protocol rtu|ascii] [uid-range <uid_range>]
Syntax
Options
crlf
When Modbus/ASCII is selected, adds a CR/LF to the end of the transmission; most
Modbus devices require this option. The default is On.
protocol
Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s),
either RTU or ASCII.
uid-range
You can specify a range of UIDs (1-247), in addition to individual UIDs. The format is
comma delimited; for example, 2-35, 50, 100-103.
Set Modbus-Master Line
Description Sets the Modbus master parameters for the line. SSL/TLS can be enabled and
configured for this Line Service.
User Level Admin
set modbus-master line .|<number>|* [crlf on|off]
[protocol rtu|ascii]
Syntax
[[entry <number> [port <port>] [protocol udp|tcp]
[range-mode gateway|host] [slave-ip <IP_address>]
[uid-range <start_uid> <end_uid>]]
Options
crlf
When Modbus/ASCII is selected, adds a CR/LF to the end of the transmission; most
Modbus devices require this option. The default is On.
protocol
Specify the protocol that is used between the Modbus Master(s) and Modbus Slave(s),
either RTU or ASCII.
entry
You can specify up to 16 Modbus Slave Remote IP Mapping entries (the UIDs must not
overlap).
port
The destination port of the remote Modbus TCP Slave that the IOLAN will connect to.
protocol
Specify the protocol that is used between the Modbus Master and Modbus Slave(s),
either TCP or UDP.
range-mode
If you specify Host, the IP address is used for the first UID specified in the range. The
last octect in the IPv4 address is then incremented for subsequent UID’s in that range.
The Host option is not applicable for IPv6 addresses. If you specify Gateway, the
Modbus Master Gateway will use the same IP address when connecting to all the
remote Modbus slaves in the specified UID range.
Line Commands 93
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
slave-ip
The IP address of the TCP/Ethernet Modbus Slave.
uid-range
When Range Mode is Host and you have sequential Modbus Slave IP addresses (for
example, 10.10.10.1, 10.10.10.2, 10.10.10.3, etc.), you can specify a UID range and the
IOLAN will automatically increment the last digit of the configured IP address.
Therefore, you can specify a UID range of 1-100, and the IOLAN will route Master
Modbus messages to all Modbus Slaves with IP addresses of 10.10.10.1 - 10.10.10.100.
Set Power-Management Line
Description Configures the power management settings for the line.
User Level Admin
set power-management line .|<number>|*
Syntax
[model rps820|rps830|rps1620|rps1630] [name <bar_name>]
set power-management line .|<number>|* plug <1-8|1-16>
[default-state on|off] [name <plug_name>]
[power-up-interval .5|1|2|5|15|30|60|120|180|300]
[serial-line <number>]
Options
model
Specify the power bar model, either RPS820, RPS830, RPS1620, RPS1630.
name (power bar name)
Specify a name for the RPS.
plug
Specify the power bar plug number you are configuring.
default-state
Sets the default state of the plug, either onor off. The default is off.
name (plug name)
Specify a name for the plug to make it easier to recognize and manage.
power-up-interval
Specify the amount of time, in seconds, that the power bar will wait before powering up
a plug. This can be useful if you have peripherials that need to be started in a specific
order.
serial-line
Associate a serial line(s) connected to a serial device that is plugged into the power bar
on that plug.
94
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Set Multihost Line
Description Configures multiple hosts or a primary/backup host schema for Silent Raw, Reverse
Raw, or Client-Inititated TruePort service types (multihost must be enabled by the line
enable multihost).
User Level Admin
set multihost line <number> entry <number> host <host> <TCP_port>
Syntax
set multihost line <number> entry <number> delete
entry
Options
You can specify up to 49 hosts in the multihost table.
host <host>
Specify the preconfigured host that will be in the multihost list.
<TCP_port>
Specify the TCP port that the IOLAN will use to communicate to the Host.
delete
Deletes the specified entry from the multihost table.
Set Line Initiate-Connection
Description Determines how the connection is initiated for Direct Telnet, Direct SSH, Direct Raw,
and Direct Rlogin.
User Level Admin
set line <number>|* initiate-connection
any-char|specific-char <hex>
any-char
Syntax
Options
Initiates a connection to the specified host when any data is received by the serial port.
specific-char <hex>
Initiates a connection to the specified host only when the specified character is received
by the serial port.
Show Custom-App
Description Shows the custom application line settings.
User Level Admin
show custom-app line .|<number>|*
Syntax
Show Interface
Description Shows the network interface information.
User Level Admin
show interface [brief|ppp|slip|ethernet]
Syntax
Show Power-Management
Description Shows the power management settings for a line.
User Level Admin
show power-management line <number>
Syntax
Line Commands 95
Download from Www.Somanuals.com. All Manuals Search And Download.
Line Service Commands
Show PPP
Description Shows the PPP line settings.
User Level Admin
show ppp line <number>|wireless-wan
Syntax
Show Rlogin-Client
Description Show the rlogin-client settings for the line.
User Level Normal, Admin
show rlogin-client line <number>
Syntax
Show SLIP
Description Show the SLIP settings for the line.
User Level Admin
show slip line <number>
Syntax
Show SSH-Client
Description Shows the SSH client settings for the line.
User Level Admin
show ssh-client line <number>
Syntax
Show Telnet-Client
Description Shows the telnet client settings for a line.
User Level Admin
show telnet-client line <number>
Syntax
Show Modbus
Description Shows the Modbus settings for a line.
User Level Admin
show modbus master|slave <number>
Syntax
Show UDP
Description Shows the UDP settings for the line.
User Level Admin
show udp line <number>
Syntax
Show Vmodem
Description Show the vmodem settings for the line.
User Level Normal, Admin
show vmodem line <number>
Syntax
Show Vmodem-Phone
Description Show the vmodem-phone entries.
User Level Normal, Admin
show vmodem-phone
Syntax
96
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Modem Commands
Modem Commands
Add Modem
Description Adds a modem.
User Level Admin
add modem <modem_name> <initialization_string>
Syntax
Options
<modem_name>
The name of the modem. Do not use spaces.
<initialization_string>
The initialisation string of the modem; see your modem’s documentation.
Delete Modem
Description Deletes a modem.
User Level Admin
delete modem <config_modem_name>
Syntax
Option
<config_modem_name>
You can see a the list of modems that can be deleted by typing delete modem ?.
Set Modem
Description Sets the modem initialization strings for a defined modem. If you wish to add a new
modem, use the add modemcommand.
User Level Admin
set modem <modem_name> <init_string>
Syntax
Options
<modem_name>
Predefined modem name.
<init_string>
Specify the initialization string for the internal modem.
Show Modems
Description Shows the IOLAN modem table.
User Level Normal, Admin
show modems
Syntax
Line Commands 97
Download from Www.Somanuals.com. All Manuals Search And Download.
Email Commands
Email Commands
Set Email-Alert Line
Description This command configures email alert parameters for the line.
User Level Admin
set email-alert line <number>|* [from <email_addr>]
Syntax
[level emergency|alert|critical|error|warning|notice|info|debug]
[mode on|off] [to <email_addr>] [reply-to <email_addr>]
[smtp-host <string>] [subject <string>] [use-server on|off]
Options
from
This field will be specified in the fromfield of the email message sent by the IOLAN.
level
Choose the event level that triggers an email notification:
z
z
z
z
z
z
z
z
Emergency
Alert
Critical
Error
Warning
Notice
Info
Debug
The list is in decreasing order of priority (Emergency has the highest priority). You are
selecting the lowest notification level; therefore, when you select Debug, you will get
an email notification for all events that trigger a message.
mode
Determines whether or not email notification is turned on. Default is Off.
to
An email address or list of email addresses that will receive the email notification.
reply-to
The email address to whom all replies to the email notification should go.
smtp-host
The SMTP host (email server) that will process the email notification request. This can
be either a host name defined in the IOLAN host table or the SMTP host IP address.
subject
A text string, which can contain spaces, that will display in the Subject field of the
email notification.
use-server
Determines whether you want the Line to inherit the Email Alert settings from the
Server Email Alert. If this is enabled, Server and Line notification events will have the
same Email Alert setting.
98
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Packet Forwarding Commands
Show Email-Alert Line
Description Shows how the line email alert is configured.
User Level Admin
show email-alert line <number>
Syntax
Packet Forwarding Commands
Set Packet-Forwarding Line
Description The Packet Forwarding feature allows you to control how the data coming from a serial
device is packetized before forwarding the packet onto the LAN network. This
command configures packet forwarding options for serial devices attached to the serial
line. The command is broken up into logical flows that can be configured; if you
configure both the packet options and the frame definition options, the frame definition
options will take precedence. If any of the packet options that are configured are met,
the packet transmission is triggered.
User Level Admin
set packet-forwarding line <number>|* mode minimize-latency
Syntax
set packet-forwarding line <number>|* mode
optimize-network-throughput
set packet-forwarding line <number>|* mode
prevent-message-fragmentation delay-between-messages <0-65535>
set packet-forwarding line <number>|*
mode custom-on-specific-events [enable-end-trigger1 on|off]
[enable-end-trigger2 on|off] [end-trigger1 <0x0-FF>]
[end-trigger2 <0x0-FF>] [force-transmit-timer <number>]
[forwarding-rule trigger1|trigger+1|trigger+2|strip-trigger]
[idle-timer <number>] [packet-size <number>]
set packet-forwarding line <number>|*
mode custom-on-fram-definition [enable-eof1 on|off]
[enable-eof2 on|off] [enable-sof1 on|off] [enable-sof2 on|off]
[eof1 <0x0-FF>] [eof2 <0x0-FF>]
[forwarding-rule trigger|trigger+1|trigger+2|strip-trigger]
[sof1 <0x0-FF>] [sof2 <0x0-FF>] [start-frame-transmit on|off]
Options
minimize-latency
This option ensures that any data received on the serial port will immediately be
forwarded to the LAN. Select this option for timing-sensitive applications.
optimize-network-throughput
This option provides optimal network usage while ensuring that the application
performance is not compromised. Select this option when you want to minimize overall
packet count, such as when the connection is over a WAN.
prevent-message-fragmentation
This option detects the message, packet, or data blocking characteristics of the serial
data and preserves it throughout the communication. Select this option for
message-based applications or serial devices that are sensitive to inter-character delays
within these messages.
Line Commands 99
Download from Www.Somanuals.com. All Manuals Search And Download.
Packet Forwarding Commands
delay-between-messages
The minimum time, in milliseconds, between messages that must pass before the data is
forwarded by the IOLAN. The range is 0-65535. The default is 250 ms.
custom-on-specific-events
This section allows you to set a variety of packet definition options. The first criteria
that is met causes the packet to be transmitted. For example, if you set a Force
Transmit Timer of 1000 ms and a Packet Size of 100 bytes, whichever criteria is met
first is what will cause the packet to be transmitted.
custom-on-frame-definition
This section allows you to control the frame that is transmitted by defining the start and
end of frame character(s). If the internal buffer (1024 bytes) is full before the EOF
character(s) are received, the packet will be transmitted and the EOF character(s) search
will continue. The default frame definition is SOF=00 and EOF=00.
enable-end-trigger1
Enable or disable the end trigger1 hex character.
enable-end-trigger2
Enable or disable the end trigger2 hex character.
enable-end-eof1
Enable or disable the eof1 (end of frame) hex character.
enable-end-eof2
Enable or disable the eof2 (end of frame) hex character.
enable-end-sof1
Enable or disable the sof1 (start of frame) hex character.
enable-end-sof2
Enable or disable the sof2 (start of frame) hex character.
end-trigger1
When enabled, specifies the character that when received will define when the packet is
ready for transmission. The transmission of the packet is based on the Trigger
Forwarding Rule. Valid values are in hex 0-FF. The default is 0.
end-trigger2
When enabled, creates a sequence of characters that must be received to specify when
the packet is ready for transmission (if the End Trigger1 character is not immediately
followed by the End Trigger2 character, the IOLAN waits for another End Trigger1
character to start the End Trigger1/End Trigger2 character sequence). The transmission
of the packet is based on the Trigger Forwarding Rule. Valid values are in hex 0-FF.
The default is 0.
eof1
Specifies the End of Frame character, which defines when the frame is ready to be
transmitted. The transmission of the frame is based on the Trigger Forwarding Rule.
Valid values are in hex 0-FF. The default is 0.
100
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Packet Forwarding Commands
eof2
When enabled, creates a sequence of characters that must be received to define the end
of the frame (if the EOF1 character is not immediately followed by the EOF2 character,
the IOLAN waits for another EOF1 character to start the EOF1/EOF2 character
sequence), which defines when the frame is ready to be transmitted. The transmission
of the frame is based on the Trigger Forwarding Rule. Valid values are in hex 0-FF. The
default is 0.
force-transmit-timer
When the specified amount of time, in milliseconds, elapses after the first character is
received from the serial port, the packet is transmitted. After a packet is transmitted, the
next character received starts the timer again. A value of zero (0) ignores this parameter.
Valid values are 0-65535 ms. The default is 0.
forwarding-rule
Determines what is included in the Frame (based on the EOF1 or EOF1/EOF2) or
Packet (based on Trigger1 or Trigger1/Trigger2). Choose one of the following options:
z
z
z
z
Strip-Trigger—Strips out the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2,
depending on your settings.
Trigger—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2,
depending on your settings.
Trigger+1—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2,
depending on your settings, plus the first byte that follows the trigger.
Trigger+2—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2,
depending on your settings, plus the next two bytes received after the trigger.
idle-timer
The amount of time, in milliseconds, that must elapse between characters before the
packet is transmitted to the network. A value of zero (0) ignores this parameter. Valid
values are 0-65535 ms. The default is 0.
packet-size
The number of byte that must be received from the serial port before the packet is
transmitted to the network. A value of zero (0) ignores this parameter. Valid values are
0-1024 bytes. The default is 0.
sof1
When enabled, the Start of Frame character defines the first character of the frame, any
character(s) received before the Start of Frame character is ignored. Valid values are in
hex 0-FF. The default is 0.
sof2
When enabled, creates a sequence of characters that must be received to create the start
of the frame (if the SOF1 character is not immediately followed by the SOF2 character,
the IOLAN waits for another SOF1 character to start the SOF1/SOF2 character
sequence). Valid values are in hex 0-FF. The default is 0.
start-frame-transmit
When enabled, the SOF1 or SOF1/SOF2 characters will be transmitted with the frame.
If not enabled, the SOF1 or SOF1/SOF2 characters will be stripped from the
transmission.
Line Commands 101
Download from Www.Somanuals.com. All Manuals Search And Download.
Packet Forwarding Commands
Show Packet-Forwarding Line
Description Shows the packet-forwarding settings for the line.
User Level Admin
show packet-forwarding line <number>
Syntax
102
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Commands
Chapter
5
5
This chapter defines all the CLI commands associated with configuring the IOLAN’s network
parameters.
SNMP Commands
Add Community
Description Adds an SNMP community (version 1 and version 2).
User Level Admin
add community <community_name> <config_host>|<IP_address>
none|readonly|readwrite
Syntax
Options
<community_name>
The name of the group that devices and management stations running SNMP belong to.
<config_host>|<IP_address>
The host name of the SNMP community that will send requests to the IOLAN.
The IPv4 or IPv6 address of the SNMP manager that will send requests to the IOLAN.
If the address is 0.0.0.0, any SNMP manager with the Community Name can access
the IOLAN. If you specify a network address, for example 172.16.0.0, any SNMP
manager within the local network with the Community Name can access the IOLAN.
none|readonly|readwrite
Permits the IOLAN to respond to SNMP requests by:
z
z
z
None—There is no response to requests from SNMP.
Readonly—Responds only to Read requests from SNMP.
Readwrite—Responds to both Read and Write requests from SNMP.
Add Trap
Description Adds an SNMP host to which trap messages will be sent. The IOLAN supports SNMP
traps for restart and SNMP community authentication error.
User Level Admin
add trap <trap_name> <config_host>|<IP_address>
Syntax
Options
<trap_name>
The trap receiver is the network management system (NMS) that should receive the
SNMP traps. This NMS must have the same SNMP community string as the trap
sender.
<config_host>|<IP_address>
Defines the hosts (by IPv4 or IPv6 address) that will receive trap messages generated by
the IOLAN. Up to four trap hosts can be defined.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
103
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Commands
Delete Community
Description Deletes an SNMP community (version 1 and version 2).
User Level Admin
delete community <config_community_number>
Syntax
Option
<config_community_number>
When you add an SNMP community, it gets assigned to a number. To delete the SNMP
community, you need to specify the number of the community that you want to delete.
To see which community is assigned to what number, type the show snmpcommand.
Delete Trap
Set SNMP
Description Deletes an SNMP trap host.
User Level Admin
delete trap <config_trap_number>
Syntax
Option
<config_trap_number>
When you add an SNMP trap host, it gets assigned to a number. To delete the SNMP
trap host, you need to specify the number of the trap host that you want to delete. To see
which trap host is assigned to what number, type the show snmpcommand.
Description Configures SNMP settings.
User Level Admin
set snmp [contact <string>] [location <string>]
[readonly user <username>] [readwrite user <username>]
Syntax
Options
contact
The name and contract information of the person who manages this SMNP node.
location
The physical location of the SNMP node.
readonly user
(SNMP version 3) Specified user can only view SNMP variables.
readwrite user
(SNMP version 3) Specified user can view and edit SNMP variables.
104
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Commands
Set SNMP V3-Security
Description Configures SNMP settings for the Version 3 read-write and read-only user.
User Level Admin
set snmp v3-security readonly [auth-algorithm md5|sha1]
[privacy-algorithm des|aes]
Syntax
[security-level none|auth/nopriv|auth/priv]
set snmp v3-security readonly auth-password|privacy-password
set snmp v3-security readwrite [auth-algorithm md5|sha1]
[privacy-algorithm des|aes]
[security-level none|auth/nopriv|auth/priv]
set snmp v3-security readwrite auth-password|privacy-password
Options
readonly auth-algorithm
Specify the authentication algorithm that will be used for the read-only user. The default
is MD5.
readonly privacy-algorithm
Specify the read-only user’s privacy algorithm (encryption). The default is DES.
readonly security-level
Select the security level for the read-only user. This must match the configuration set up
in the SNMP manager. The default is none.
readonly auth-password
Specify the auth password for the V3 read-only user. You will be prompted to retype the
password.
readonly privacy-password
Specify the privacy password for the V3 read-only user. You will be prompted to retype
the password.
readwrite auth-algorithm
Specify the authentication algorithm that will be used for the read-write user. The
default is MD5.
readwrite privacy-algorithm
Specify the read-write user’s privacy algorithm (encryption). The default is DES.
readwrite security-level
Select the security level for the read-writer user. This must match the configuration set
up in the SNMP manager. The default is none.
readwrite auth-password
Specify the auth password for the V3 read-write user. You will be prompted to retype
the password.
readwrite privacy-password
Specify the privacy password for the V3 read-write user. You will be prompted to
retype the password.
Network Commands 105
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP Commands
Show SNMP
Description Shows SNMP settings, including communities and traps.
User Level Admin
show snmp
Syntax
TFTP Commands
Set Server TFTP
Description Configures the IOLANs TFTP client settings.
User Level Admin
set server tftp [retry <integer>] [timeout <integer>]
Syntax
Options
retry
The number of times the IOLAN will retry to transmit a TPFT packet to/from a host
when no response is received. Enter a value between 0 and 5. The default is 5. A value
of 0 (zero) means that the IOLAN will not attempt a retry should TFTP fail.
timeout
The time, in seconds, that the IOLAN will wait for a successful transmit or receipt of
TFTP packets before retrying a TFTP transfer. Enter a value between 3 and 10. The
default is 3 seconds.
Hosts Commands
Add Host
Description Adds a host to the IOLAN host table.
User Level Admin
add host <hostname> <IP_address>
Syntax
add host <hostname> fqdn <text>
Options
<hostname>
The name of the host.
<IP_address>
The host IPv4 or IPv6 address.
fqdn
When you have DNS defined in the IOLAN, you can enter a DNS resolvable fully
qualified domain name (note: FQDN’s are excluded as accessible hosts when IP
Filtering is enabled).
Delete Host
Description Deletes a host from the IOLAN host table.
User Level Admin
delete host <config_host>
Syntax
Option
<config_host>
You can see a list of hosts that can be deleted by typing delete host ?.
106
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
DNS/WINS Commands
Set Host
Description Configures a host in the IOLAN host table.
User Level Admin
set host <config_host> <IP_address>
Syntax
set host <config_host> fqdn <text>
Options
<config_host>
The name of the host.
<IP_address>
The host IPv4 or IPv6 address.
fqdn
When you have DNS defined in the IOLAN, you can enter a DNS resolvable fully
qualified domain name (note: FQDN’s are excluded as accessible hosts when IP
Filtering is enabled).
Show Hosts
Description Shows the IOLAN host table.
User Level Normal, Admin
show hosts
Syntax
DNS/WINS Commands
Add DNS
Description Adds a DNS entry.
User Level Admin
add dns <IP_address>
Syntax
Option
<IP_address>
You can specify the IPv4 or IPv6 addresses for up to four DNS (Domain Name Servers)
hosts in your network.
Add WINS
Description Adds a WINS entry.
User Level Admin
add wins <IP_address>
Syntax
Option
<IP_address>
You can specify the IPv4 addresses for up to four WINS (Windows Internet Naming
Service) hosts in your network.
Network Commands 107
Download from Www.Somanuals.com. All Manuals Search And Download.
DNS/WINS Commands
Delete DNS
Description Deletes a DNS entry.
User Level Admin
delete dns <config_dns_addr>
Syntax
Option
<config_dns_addr>
You can view a list of configured DNS server IP addresses to choose from by typing
delete dns ?.
Delete WINS
Description Deletes a WINS entry.
User Level Admin
delete wins <config_wins_addr>
Syntax
Option
<config_wins_addr>
You can view a list of configured WINS server IP addresses to choose from by typing
delete wins ?.
Show DNS
Description Shows all DNS entries, even those supplied by DHCP/BOOTP when applicable.
User Level Admin, Normal
show dns
Syntax
Show Server
Description Shows the server configuration, including configured WINS or DNS servers.
User Level Admin, Normal
show server
Syntax
Show WINS
Description Shows all WINS entries, even those supplied by DHCP/BOOTP when applicable.
User Level Admin, Normal
show wins
Syntax
108
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Gateway Commands
Gateway Commands
Add Gateway
Description Adds a gateway. You can configure up to twenty gateways.
User Level Admin
add gateway <config_host> default
Syntax
add gateway <config_host> host <dest_IP_addr>
add gateway <config_host> network
<dest_IPv4_addr>|<dest_IPv6_addr>
[<subnet_bits_0-32>|<prefix_bits_0-128>]
add gateway specify-gateway ipv6tunnel <tunnel_name> default|
host <dest_IP_addr>|
network <dest_IPv4_addr>|<dest_IPv6_addr>
[<subnet_bits_0-32>|<prefix_bits_0-128>]
add gateway specify-gateway serial-port ppp <line_name>|
slip <line_name> default|
host <dest_IP_addr>|
network <dest_IPv4/IPv6_addr>
[<subnet_bits_0-32>|<prefix_bits_0-128>]
Options
<config_host>
You can specify up to 20 hosts on desktop models and 49 hosts on rack mount and
medical unit models to act as gateways in your network. Each gateway host must be
defined in the IOLAN’s host table.
default|host|network
Specify the type of gateway:
z
z
Default—A gateway which provides general access beyond your local network.
Host—(Default) A gateway reserved for accessing a specific host external to your
local network.
z
Network—A gateway reserved for accessing a specific network external to your
local network.
ipv6tunnel <tunnel_name>
Specify the configured IPv6 tunnel that you want to use as the gateway to the
destination.
serial-port ppp|slip <line_name>
Specify the PPP or SLIP configured line that you want to use as the gateway to the
destination.
<dest_IP_addr>
When the gateway is a Host or Network gateway, you must specify the IPv4 or IPv6
address of the target host machine/network.
<subnet_bits>|<prefix_bits>
When the gateway is a Network gateway, you must specify the network’s subnet mask
(IPv4) or prefix bits (IPv6).
Network Commands 109
Download from Www.Somanuals.com. All Manuals Search And Download.
Gateway Commands
Delete Gateway
Description Deletes a gateway.
User Level Admin
delete gateway <config_gateway_host>
Syntax
Option
<config_gateway_host>
You can view the configured gateways that can be deleted by typing
delete gateway ?.
Set Gateway
Description Configures the gateway.
User Level Admin
set gateway <config_gateway_host> default
Syntax
set gateway <config_gateway_host> host <destination_ip>
set gateway <config_gateway_host>
network <dest_IPv4_addr>|<dest_IPv6_address> <prefixbits_mask>
Options
<config_gateway_host>
You can view the configured gateways that can be deleted by typing
delete gateway ?.
default|host|network
Specify the type of gateway:
z
z
Default—A gateway which provides general access beyond your local network.
Host—(Default) A gateway reserved for accessing a specific host external to your
local network.
z
Network—A gateway reserved for accessing a specific network external to your
local network.
<destination_ip>
When the gateway is a Host or Network gateway, you must specify the IPv4 or IPv6
address of the target host machine/network.
<prefixbits_mask>
When the gateway is a Network gateway, you must specify the network’s subnet mask
for an IPv4 destination IP address (the address is in the form of 123.123.123.123) or
prefix bits for an IPv6 destination IP address (valid values are 0-128).
Show Gateways
Description Shows configured gateways.
User Level Normal, Admin
show gateways
Syntax
110
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Logging Commands
Logging Commands
Set Syslog
Description Configures the system log.
User Level Admin
set syslog
Syntax
[level emergency|alert|critical|error|warning|notice|info|debug]
[primary-host <config_host>] [secondary-host <config_host>]
Options
level
Choose the event level that triggers a syslog entry:
z
z
z
z
z
z
z
z
Emergency
Alert
Critical
Error
Warning
Notice
Info
Debug
When you select a Level, all the levels that appear above it in the list also trigger a
syslog entry. For example, if you select Error, all Error, Critical, Alert, and Emergency
events will be logged.
primary-host
The first preconfigured host that the IOLAN will attempt to send system log messages
to; messages will be displayed on the host’s monitor.
secondary-host
If the IOLAN cannot communicate with the primary host, then the IOLAN will attempt
to send system log messages to this preconfigured host; messages will be displayed on
the host’s monitor.
Show Syslog
Description Shows the syslog settings.
User Level Admin
show syslog
Syntax
Network Commands 111
Download from Www.Somanuals.com. All Manuals Search And Download.
RIP Commands
RIP Commands
Add RIP
Description Adds a RIP MD5 key. After pressing Enter, you will be prompted for the MD5 key
value.
User Level Admin
add rip md5 <integer_md5_id> <start_date> <start_time> <end_date>
<end_time>
Syntax
Options
<integer_md5_id>
The MD5 identification key.
<start_date>
The start date that the MD5 key becomes valid. The date format is dependent on your
system’s settings.
<start_time>
The time that the MD5 key becomes valid. The time format is dependent on your
system’s settings.
<end_date>
The last day that the MD5 key is valid. The date format is dependent on your system’s
settings.
<end_time>
The time that the MD5 key becomes invalid. The time format is dependent on your
system’s settings.
Delete RIP
Description Deletes a RIP MD5 key.
User Level Admin
delete rip md5 <integer_md5_id>
Syntax
Option
<integer_md5_id>
You can see a list of MD5 IDs available for deletion by typing delete rip md5 ?.
112
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
RIP Commands
Set RIP
Description Configures the RIP MD5 key. After pressing Enter, you will be prompted for the MD5
key value.
User Level Admin
set rip [authentication none|password|md5]
[ethernet-mode none|send|listen|send-and-listen]
Syntax
set rip password
set rip md5 <config_md5_id> [end <date> <time>]
[start <date> <time>] [key]
Options
authentication
Specify the type of RIP authentication:
z
z
z
None—No authentication for RIP.
Password—Simple RIP password authentication.
MD5—Use MD5 RIP authentication.
ethernet-mode
Enable/disable RIP (Routing Information Protocol) mode for the Ethernet interface with
one of the following options:
z
z
z
z
None—Disables RIP over the Ethernet interface.
Send—Sends RIP over the Ethernet interface.
Listen—Listens for RIP over the Ethernet interface.
Send and Listen—Sends RIP and listens for RIP over the Ethernet interface.
password
When you type the set rip passwordcommand and press Enter, you will be
prompted to type in a password and then re-enter that password.
<configured_md5_id>
The MD5 identification key.
end <date> <time>
The last day that the MD5 key is valid. Specify as dd/mm/yyyy.
The time that the MD5 key becomes invalid. Specify as hh:mm:[ss].
start <date> <time>
The start date that the MD5 key becomes valid. Specify as dd/mm/yyyy.
The time that the MD5 key becomes valid. Specify as hh:mm:[ss].
key
When you press Enter after typing the keycommand, you will be prompted to enter the
MD5 key value and then re-enter the key value.
Show RIP
Description Shows the RIP settings.
User Level Normal, Admin
show rip
Syntax
Network Commands 113
Download from Www.Somanuals.com. All Manuals Search And Download.
IPsec Commands
Show RIP Peers
Description Shows current information about IPv4 or IPv6 RIP peers.
User Level Normal, Admin
show rip peers [ipv6]
Syntax
IPsec Commands
Once there is an active VPN tunnel, the IOLAN expects all connections to be established through a
VPN tunnel. To allows hosts to connect outside of the VPN tunnel, you must configure VPN
Add IPsec
Description Adds an IPsec tunnel.
User Level Admin
add ipsec <tunnel_name>
Syntax
Option
<tunnel_name>
The name of an IPsec VPN tunnel. You can configure up to 64 VPN tunnels.
Set IPsec
Description Configures the IPsec tunnel.
User Level Admin
set ipsec <config_tunnel_name>
Syntax
[authentication-method shared-secret|rsa-signature|x.509-certificate]
[boot-action start|add|ignore] [local-device left|right]
[local-external-ip-address <IPv4/IPv6_address/FQDN>]
[local-host-network <IPv4_addr> <subnet_mask>|
<IPv6_address> <prefix_bits>]
[local-ip-address <IPv4/IPv6_address/FQDN>]
[local-next-hop <IPv4/IPv6_address>]
[remote-external-ip-address <IPv4/IPv6_address/FQDN>]
[remote-host-network <IPv4_addr> <subnet_mask>|
<IPv6_address> <prefix_bits>]
[remote-ip-address <IPv4/IPv6_address/FQDN>]
[remote-next-hop <IPv4/IPv6_address>]
[remote-validation-criteria
country <code>|state-province <text>|locality <text>
|organisation <text>|organisation-unit <text>
|common-name <text>|email <email_addr>]
set ipsec <config_tunnel_name> secret <text>
set ipsec use-nat-traversal enabled|disabled
114
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
IPsec Commands
Options
authentication-method
Specify the authentication method that will be used between VPN peers to authenticate
the VPN tunnel.
Data Options:
z
z
Shared Secret—A text-based secret that is used to authenticate the IPsec tunnel
(case sensitive).
RSA Signature—RSA signatures are used to authenticate the IPsec tunnel. When
using this authentication method, you must download the IPsec RSA public key to
the IOLAN and upload the IPsec RSA public key from the IOLAN to the VPN
gateway.
z
X.509 Certificate—X.509 certificates are used to authenticate the IPsec tunnel.
When using this authentication method, you must include the signing authority’s
certificate information in the SSL/TLS CA list and download it to the IOLAN.
The default is shared secret.
boot-action
Determines the state of the VPN network when the IOLAN is booted.
z
z
z
Start—Starts the VPN network, initiating communication to the remote VPN.
Add—Adds the VPN network, but doesn’t initiate a connection to the remote VPN.
Ignore—Maintains the VPN network configuration, but the VPN network is not
started and cannot be started through the IPsec command option.
When defining peer VPN gateways, one side should be defined as Start (initiate) and
the other as Add (listen). It is invalid to define both gateways as Add. VPN connection
time can take longer when both gateways are set to Start, as both sides will attempt to
initiate the same VPN connection.
The default is start.
local-device
When the VPN tunnel is established, one side of the tunnel is designated as Right and
the other as Left. You are configuring the IOLAN-side of the VPN tunnel. The default
is left.
local-external-ip-address
When NAT Traversal (NAT_T) is enabled, this is IOLAN’s external IPv4 or IPv6
address or FQDN. When the IOLAN is behind a NAT router, this will be its public IP
address.
local-host-nextwork
The IPv4 or IPv6 address of a specific host, or the network address that the IOLAN will
provide a VPN connection to.
local-ip-address
The IPv4 or IPv6 address or FQDN of the IOLAN. You can specify %defaultroute
when the IP address of the IOLAN is not always known (for example, when it gets its
IP address from DHCP). When %defaultrouteis used, a default gateway must be
configured in the route table.
local-next-hop
The IPv4 or IPv6 address of the router/gateway that will forward data packets to the
remote VPN (if required). The router/gateway must reside on the same subnet at the
IOLAN. Leave this parameter blank if you want to use the Default Gateway configured
in the IOLAN.
Network Commands 115
Download from Www.Somanuals.com. All Manuals Search And Download.
IPsec Commands
remote-external-ip-address
When NAT Traversal (NAT_T) is enabled, the remote VPN’s public external IPv4 or
IPv6 address or FQDN. If you want to accept a VPN connection from any host/network,
you can enter %anyin this field.
remote-host-nextwork
The IPv4 or IPv6 address of a specific host or the network address that the IOLAN will
provide a VPN connection to. If the IPsec tunnel is listening for connections (Boot
Action set to Add), and the field value is left at 0.0.0.0, any VPN peer with a private
remote network/host that conforms to RFC 1918 (10.0.0.0/8, 172.16.0.0./12,
192.168.0.0/16) will be allowed to use this tunnel if it successfully authenticates.
remote-ip-address
The IPv4 or IPv6 address or FQDN of the remote VPN peer. If you want to accept a
VPN connection from any VPN peer, you can enter %anyin this field.
remote-next-hop
The IPv4 or IPv6 address of the router/gateway that will forward data packets to the
IOLAN (if required). The router/gateway must reside on the same subnet at the remote
VPN.
remote-validation-criteria
Any values that are entered in the remote validation criteria must match the remote
X.509 certificate for a succsessful connection; any fields left blank will not be validated
against the remote X.509 certificate. Note that all validation criteria must be configured
to match the X.509 certificate. An asterick (*) is valid as a wildcard.
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the remote X.509 certificate. An asterisk (*)
works as a wildcard.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the remote X.509 certificate.
An asterisk (*) works as a wildcard.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the remote X.509 certificate.
An asterisk (*) works as a wildcard.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the remote X.509
certificate. An asterisk (*) works as a wildcard.
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the remote
X.509 certificate. An asterisk (*) works as a wildcard.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the remote X.509 certificate. An asterisk (*) works as a wildcard.
116
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Tunnels
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the remote
X.509 certificate. An asterisk (*) works as a wildcard.
secret
When the Authentication Method is set to Shared Secret, enter the case-sensitive
secret word. Maximum of 16 characters, spaces not allowed. The secret is shared for all
IPsec and L2TP/IPsec tunnels.
use-nat-traversal
NAT Traversal should be enabled when the IOLAN is communicating through a
router/gateway to a remote VPN that also has NAT Traversal enabled. By default, this is
enabled.
Show IPsec
Description Dispalys an IPsec tunnel.
User Level Admin
show ipsec <config_tunnel_name>
Syntax
Option
<config_tunnel_name>
Displays the configuration information for the specified IPsec tunnel.
IPsec
Description Controls the state of all IPsec tunnels.
User Level Admin
ipsec start|stop|restart|status
Syntax
Options
start
Starts all IPsec VPN tunnels.
stop
Stops all IPsec VPN tunnels.
restart
Stops and then starts all IPsec VPN tunnels.
status
Used strictly for debugging, displays trace data for all IPsec tunnels.
IPv6 Tunnels
Add IPv6tunnel
Description Addes a new IPv6 tunnel.
User Level Admin
add ipv6tunnel <tunnel_name>
Syntax
Option
<tunnel_name>
Adds the specified IPv6 tunnel.
Network Commands 117
Download from Www.Somanuals.com. All Manuals Search And Download.
IPv6 Tunnels
Set IPv6tunnel
Description Configures the specified IPv6 tunnel.
User Level Admin
set ipv6tunnel <config_tunnel_name> [mode manual|teredo|6to4]
[gateway <interface>] [remote-host <config_host>]
Syntax
Options
mode
The method or protocol that is used to create the IPv6 tunnel.
z
Manual—When enabled, the IOLAN will manually create the IPv6 tunnel to the
specified Remote Host through the specified Interface.
z
6to4—When enabled, the IOLAN will broadcast to the multicast address
192.88.99.1 through the specified Interface. When the closest 6to4 router responds,
it will create the IPv6 tunnel, encapsulating and decapsulating IPv6 traffic sent to
and from the IOLAN.
z
Teredo—When enabled, the Teredo protocol encapsulates the IPv6 packet as an
IPv4 UDP message, allowing it to pass through most network address translator
(NAT) boxes and create an IPv6 tunnel to the specified Remote Host (a Teredo
server) through the specified Interface.
Default: Manual
gateway
The interface that the IOLAN is going to use to access the Remote Host. The list is
comprised of the Ethernet interface(s) and serial ports configured PPP or SLIP.
Default: ethernet_1
remote-host
The IPv4 host that can access the IPv6 network when the Mode is Manual.
The Teredo server when the Mode is Teredo.
Default: None
Show IPv6tunnel
Description Shows the specified IPv6 tunnel settings.
User Level Admin
show ipv6tunnel <config_tunnel_name>
Syntax
Delete IPv6tunnel
Description Controls the state of all IPsec tunnels.
User Level Admin
delete ipv6tunnel <config_tunnel_name>
Syntax
Options
<config_tunnel_name>
Deletes the specified IPv6 tunnel. If a tunnel is associated with a gateway, it cannot be
deleted until the gateway is either changed or deleted.
118
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
L2TP/IPsec
L2TP/IPsec
Once L2TP/IPsec is enabled, the IOLAN expects all connections to be established through a VPN
tunnel. To allows hosts to connect outside of the VPN tunnel, you must configure VPN exceptions,
Set L2TP
Description
User Level Admin
set l2tp listen-for-l2tp on|off
Syntax
set l2tp authentication-method shared-secret [secret <text>]
set l2tp authentication-method x.509-certificate
remote-validation-criteria [country <code>]
[state-province <text>] [locality <text>] [organisation <text>]
[organisation-unit <text>] [common-name <text>]
[email <email_addr>]
set l2tp [ipsec-local-ip-address <ipv4_addr>]
[local-ip-address <ipv4_addr>]
[remote-ipv4-start-address <start_ip>]
[remote-ipv4-end-address <end_ip>]
[authentication-type pap|chap|both]
Options
listen-for-l2tp
When enabled, allows L2TP/IPsec VPN connections. Note: to allow non-VPN
connections to the IOLAN, you must create entries in the VPN Exceptions list. The
default is off.
authentication methed shared-secret|x.509-certificate
Specify the authentication method that will be used between VPN peers to authenticate
the VPN tunnel.
Data Options:
z
z
Shared Secret—A text-based secret that is used to authenticate the IPsec tunnel
(case sensitive).
X.509 Certificate—X.509 certificates are used to authenticate the IPsec tunnel.
When using this authentication method, you must include the signing authority’s
certificate information in the SSL/TLS CA list and download it to the IOLAN.
Default: Shared Secret
secret
When the Authentication Method is Secret, enter the case-sensitive secret word.
Maximum of 16 characters, spaces not allowed. The secret is shared for all IPsec and
L2TP/IPsec tunnels.
remote-validation-criteria
Any values that are entered in the remote validation criteria must match the remote
X.509 certificate for a succsessful connection; any fields left blank will not be validated
against the remote X.509 certificate. Note that all validation criteria must be configured
to match the X.509 certificate. An asterick (*) is valid as a wildcard.
Network Commands 119
Download from Www.Somanuals.com. All Manuals Search And Download.
L2TP/IPsec
country
A two character country code; for example, US. This field is case sensitive in order to
successfully match the information in the remote X.509 certificate. An asterisk (*)
works as a wildcard.
state-province
Up to a 128 character entry for the state/province; for example, IL. This field is case
sensitive in order to successfully match the information in the remote X.509 certificate.
An asterisk (*) works as a wildcard.
locality
Up to a 128 character entry for the location; for example, a city. This field is case
sensitive in order to successfully match the information in the remote X.509 certificate.
An asterisk (*) works as a wildcard.
organisation
Up to a 64 character entry for the organisation; for example, Accounting. This field is
case sensitive in order to successfully match the information in the remote X.509
certificate. An asterisk (*) works as a wildcard.
organisation-unit
Up to a 64 character entry for the unit in the organisation; for example, Payroll. This
field is case sensitive in order to successfully match the information in the remote
X.509 certificate. An asterisk (*) works as a wildcard.
common-name
Up to a 64 character entry for common name; for example, the host name or fully
qualified domain name. This field is case sensitive in order to successfully match the
information in the remote X.509 certificate. An asterisk (*) works as a wildcard.
email
Up to a 64 character entry for an email address; for example, [email protected].
This field is case sensitive in order to successfully match the information in the remote
X.509 certificate. An asterisk (*) works as a wildcard.
ipsec-local-ip-address
The IPv4 address that the IOLAN will listen on for L2TP/IPsec connections. If the
default value (0.0.0.0) is kept, the IOLAN will use the Default Gateway value (if no
Default Gateway is specified, L2TP/IPsec VPN connections will error out).
Default: 0.0.0.0
local-ip-address
Specify the unique IPv4 address that hosts accessing the IOLAN through the L2TP
tunnel will use.
Field Format: IPv4 address
local-ipv4-start-address
Specify the first IPv4 address that can be assigned to incoming hosts through the L2TP
tunnel.
Field Format: IPv4 address
local-ipv4-end-address
Specify the end range of the IPv4 addresses that can be assinged to incoming hosts
through the L2TP tunnel.
Field Format: IPv4 address
120
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
VPN Exceptions
authentication-type
Specify the authentication method that will be used for the L2TP tunnel.
Data Options: CHAP, PAP, Both
Default: Both
Show LT2P
Description Shows the L2TP settings.
User Level Admin
show l2tp
Syntax
VPN Exceptions
VPN exceptions allows specific hosts or any host in a network to connect to the IOLAN outside of a
VPN tunnel.
Add VPN Exception
Description Adds a VPN exception.
User Level Admin
add vpn-exception network-ip <ipv4_net_ip> <network_subnet>|
<ipv6_net_ip> <prefix_bits>
Syntax
add vpn-exception host-ip <ipv4/ipv6_address>
Options
network-ip <ipv4_net_ip> <network_subnet>|<ipv6_net_ip> <prefix_bits>
The network address that will communicate with the IOLAN outside of the VPN tunnel.
If the address is IPv4, you can supply the subnet mask for the network (the default is
0.0.0.0). If the address is IPv6, you can supply the prefix bits for the network (the
default is 64, the range is 0-128).
host-ip <ipv4/ipv6_address>
The IP address of the host that will communicate with the IOLAN outside of the VPN
tunnel.
Field Format: IPv4 or IPv6 address
Set VPN Exception
Description Configures an existing VPN exception.
User Level Admin
set vpn-exception <config_vpn_except>
network-ip <ipv4_address> <network_subnet>|
Syntax
<ipv6_address> <prefix_bits>
set vpn-exception <config_vpn_except> host-ip <ipv4/ipv6_address>
Options
network-ip <ipv4_net_ip> <network_subnet>|<ipv6_net_ip> <prefix_bits>
The network address that will communicate with the IOLAN outside of the VPN tunnel.
If the address is IPv4, you can supply the subnet mask for the network (the default is
0.0.0.0). If the address is IPv6, you can supply the prefix bits for the network (the
default is 64, the range is 0-128).
Network Commands 121
Download from Www.Somanuals.com. All Manuals Search And Download.
VPN Exceptions
host-ip <ipv4/ipv6_address>
The IP address of the host that will communicate with the IOLAN outside of the VPN
tunnel.
Field Format: IPv4 or IPv6 address
Delete VPN Exception
Description Deletes a VPN exception. To see a list of configured VPN exceptions, type
delete vpn-exception ?
User Level Admin
delete vpn-exception <config_vpn_except>
Syntax
Show VPN Exception
Description Shows the configured VPN exceptions.
User Level Admin
show vpn-exception
Syntax
122
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Time Commands
Chapter
6
6
This chapter defines all the CLI commands associated with configuring the IOLAN’s time
parameters.
Server Commands
Set Time
Description Sets the IOLAN’s system clock.
User Level Admin
set time <hh:mm[:ss]>
Syntax
Option
<hh:mm[:ss]>
Sets the IOLAN’s system time, using the 24-hour clock time format (00:00-23:59).
Set Timezone
Description Sets the IOLAN's time zone name and its offset from Greenwich Mean Time (UTC).
User Level Admin
set timezone [name <string>] [offset +|-<hh[:mm]>]
Syntax
Options
<name>
The name of the time zone to be displayed during standard time. Maximum 4 characters
and minimum 3 characters (do not use angled brackets < >).
offset
The offset from UTC for your local time zone. Specify in the format of hours hh (valid
-12 to +14) and minutes mm (valid 0 to 59 minutes) for the offset from UTC.
Show Time
Description Shows the IOLAN’s system clock.
User Level Normal, Admin
show time
Syntax
Show Timezone
Description Shows the time zone settings.
User Level Admin
show timezone
Syntax
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
123
Download from Www.Somanuals.com. All Manuals Search And Download.
SNTP Commands
SNTP Commands
Add SNTP
Description Adds an SNTP server.
User Level Admin
add sntp [server-1 <config_host>] [server-2 <config_host>]
Syntax
Options
server-1
The name of the primary SNTP server from the IOLAN host table. Valid with Unicast
and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
server-2
The name of the secondary SNTP server from the IOLAN host table. Valid with
Unicast and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
Delete SNTP
Description Deletes an SNTP server.
User Level Admin
delete sntp server-1|server-2
Syntax
Options
server-1
The name of the primary SNTP server from the IOLAN host table. Valid with Unicast
and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
server-2
The name of the secondary SNTP server from the IOLAN host table. Valid with
Unicast and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
Set SNTP
Description Configures an SNTP server.
User Level Admin
set sntp mode none|unicast|anycast|multicast
[server-1 <config_host>] [server-2 <config_host>]
Syntax
[version 1|2|3|4]
Options
mode
The SNTP mode. Valid modes are:
z
z
None—SNTP is turned off.
Unicast—Sends a request packet periodically to the Primary host. If
communication with the Primary host fails, the request will be sent to the
Secondary host.
z
z
Multicast—Listen for any broadcasts from an SNTP server and then synchronizes
its internal clock to the message.
Anycast—Sends a request packet as a broadcast on the LAN to get a response
from any SNTP server. The first response that is received is used to synchronize its
internal clock and then operates in Unicast mode with that SNTP server.
124
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Time/Date Setting Commands
server-1
The name of the primary SNTP server from the IOLAN host table. Valid with Unicast
and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
server-2
The name of the secondary SNTP server from the IOLAN host table. Valid with
Unicast and Multicast modes, although in Multicast mode, the IOLAN will only accept
broadcasts from the specified host SNTP server.
version
Version of SNTP. Valid values are 1 to 4. Default value is 4.
Show SNTP
Description Shows the SNTP settings.
User Level Admin
show sntp
Syntax
Show SNTP-Info
Description Shows current SNTP information.
User Level Admin
show sntp-info
Syntax
Time/Date Setting Commands
Set Date
Description Sets the IOLAN’s system clock.
User Level Admin
set date <dd/mm/yyyy>
Syntax
Set Summertime
Description Sets the summertime clock.
User Level Admin
set summertime [mode none|fixed|recurring] [name <text>]
[offset <hh:mm>]
Syntax
Options
mode
You can configure the summer time to take effect:
z
z
None—No summer time change.
Fixed—The summer time change goes into effect at the specified time every year.
For example, April 15 at 1:00 pm.
z
Recurring—The summer time changes goes into effect every year at same relative
time. For example, on the third week in April on a Tuesday at 1:00 pm.
<name>
The name of the configured summer time zone; this will be displayed during the
summer time setting. Maximum 4 characters and minimum 3 characters (do not use
angled brackets < >). If this parameter is not set, then the summertime feature will not
work.
Time Commands 125
Download from Www.Somanuals.com. All Manuals Search And Download.
Time/Date Setting Commands
offset
The offset from UTC for your local time zone. Specify in the format of hours hh (valid
-12 to +14) and minutes mm (valid 0 to 59 minutes) for the offset from UTC.
Set Summertime Fixed
Description Sets the summertime clock to start on the same date each year, for example, April 15 at
1:00 pm.
User Level Admin
set summertime fixed
Syntax
[start-date january|february |... <0-31>] [start-time <hh:mm>]
[end-date january|february|... <0-31>] [end-time <hh:mm>]
Options
start-date
The date to change to summer time and end standard time.
start-time <hh:mm>
The time to change to summertime. Valid values are 00:00 to 23:59.
end-date
The date to end summer time and start standard time.
end-time <hh:mm>
The time to change to standard time. Valid values are 00:00 to 23:59.
Set Summertime Recurring
Description Sets the summertime clock to start at the same relative time each year; for example, on
the third week in April on a Tuesday at 1:00 pm.
User Level Admin
set summertime recurring [start-day monday|tuesday|...]
[start-month january|february|...] [start-time <hh:mm>]
[start-week 1|2|3|4|5|last] [end-day monday|tuesday|...]
[end-month january|february|...] [end-time <hh:mm>]
[end-week 1|2|3|4|5|last]
Syntax
Options
start-day
The day to change to summer time from standard time.
start-month
The month to change to summer time from standard time.
start-time
The time to change to summer time from standard time; uses the format hh:mm for a
24-hour clock (00:00-23:59).
start-week
The week to change to summer time from standard time.
end-day
The day to end summer time and start standard time.
end-month
The month to end summer time and start standard time.
126
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Time/Date Setting Commands
end-time
The time to end summer time and start standard time; uses the format hh:mm for a
24-hour clock (00:00-23:59).
end-week
The week to end summer time and start standard time.
Show Date
Description Shows the date, according to the IOLAN system clock.
User Level Normal, Admin
show date
Syntax
Show Summertime
Description Shows the summertime settings.
User Level Admin
show summertime
Syntax
Time Commands 127
Download from Www.Somanuals.com. All Manuals Search And Download.
Time/Date Setting Commands
128
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Administration
Commands
Chapter
7
7
This chapter defines all the CLI commands associated with configuring the IOLAN’s administration
parameters.
Bootup Commands
Reboot
Description Reboots the IOLAN. You will be prompted to save configuration to FLASH, if there
have been unsaved configuration changes.
User Level Admin
reboot
Syntax
Reset
Description Resets the user profile or serial line to the default factory configuration.
User Level Admin
reset user .|<username>|*
Syntax
reset line <number>|*
Reset Factory
Description Resets the IOLAN to the factory configuration.
User Level Admin
reset factory
Syntax
Save
Description Saves the configuration to FLASH.
User Level Admin
save
Syntax
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
129
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP File Transfer Commands
Set Bootup
Description Specifies remote the TFTP host and pathname for files to be loaded after a IOLAN
reboot.
User Level Admin
set bootup firmware host <hostname> [file <path_filename>]
Syntax
set bootup configuration host <hostname> [file <path_filename>]
Options
firmware file
The path and file name, relative to the default path of your TFTP server software, of the
update software for the IOLAN that will be loaded when the IOLAN is rebooted.
configuration file
The path and file name, relative to the default path of your TFTP server software, of the
configuration software for the IOLAN that will be loaded when the IOLAN is rebooted.
host
The host name or IP address of the server that contains the configuration or firmware
file. If you use a host name, it must exist in the IOLAN’s host table or be resolved by
DNS.
Show ARP
Description Shows the current contents of the ARP cache.
User Level Admin
show arp
Syntax
Show Bootup
Description Shows the Firmware and Configuration files specified for IOLAN bootup.
User Level Admin
show bootup
Syntax
TFTP File Transfer Commands
Netload
Description Transfers a file from a remote host to the IOLAN using the TFTP protocol.
User Level Admin
netload text-config|factory-default-config|firmware|
configuration|customlang|term1|term2|term3|customapp-file|
Syntax
wan-driver <hostname/IP_address> <filename>
Options
text-config
Specify this option if you are uploading a text-based configuration file to the IOLAN
from a TFTP server.
factory-default-config
Specifies the configuration file that you are going to load from a TFTP server to the
IOLAN that will act as the factory default configuration. See the User Guide for
directions on how to revert back to the original factory default configuration, if
required.
firmware
Specifies that you are going to download a new firmware file to the IOLAN.
130
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP File Transfer Commands
configuration
Specifies that you are going to download a new configuration file to the IOLAN.
customlang
Specifies that you are going to download a custom language file to the IOLAN.
term1|term2|term3
You can create and download up to three custom terminal definitions to the IOLAN.
customapp-file
You can download multiple SDK program executables and ancillary files using this
command by running the command multiple times to download multiple files. Use the
shellCLI command as described in the SDK Programmer’s Guide to manage the files
that you download.
wan-driver
Download wireless WAN custom drivers to the IOLAN that have been downloaded
from the Perle website.
<hostname/IP_address>
The IP address or host name where the file you are downloading to the IOLAN resides.
If you are using a host name, it must be resolved in either the IOLAN’s Host Table or a
DNS server.
<filename>
The complete path and file name of the file you are downloading to the IOLAN (this
path should be relative to the default path of your TFTP server, which may or may not
allow drive letters).
Netsave
Description Transfers a file from the IOLAN to a remote host using the TFTP protocol.
User Level Admin
netsave configuration|crash|serialt-buf|text-config
<hostname/IP_address> <filename>
Syntax
Options
configuration
Specifies that you are going to upload a configuration file from the IOLAN to the
specified host or IP address.
crash
Specifies that you are going to upload a crash file from the IOLAN to the specified host
or IP address.
serialt-buf
Specifies that you are going to upload the contents of the serial trace buffer.
text-config
Saves the current configuration to a text file on a TFTP server.
<hostname/IP_address>
The IP address or host name for where the file you are uploading from the IOLAN is
going. If you are using a host name, it must be resolved in either the IOLAN’s Host
Table or a DNS server.
Administration Commands 131
Download from Www.Somanuals.com. All Manuals Search And Download.
Custom Factory Default
<filename>
The complete path and file name for the file you are uploading from the IOLAN (this
path should be relative to the default path of your TFTP server, which may or may not
allow drive letters).
Custom Factory Default
Netload
Description Transfers a file from a remote host to the IOLAN using the TFTP protocol.
User Level Admin
netload factory-default-config <hostname/IP_address> <filename>
Syntax
Options
factory-default-config
Specifies the configuration file that you are going to load from a TFTP server to the
IOLAN that will act as the factory default configuration. See the User Guide for
directions on how to revert back to the original factory default configuration, if
required.
<hostname/IP_address>
The IP address or host name where the file you are downloading to the IOLAN resides.
If you are using a host name, it must be resolved in either the IOLAN’s Host Table or a
DNS server.
<filename>
The complete path and file name of the file you are downloading to the IOLAN (this
path should be relative to the default path of your TFTP server, which may or may not
allow drive letters).
Set
Description Sets the current configuration on IOLAN to act as the factory default configuration. See
the User Guide for directions on how to revert back to the original factory default
configuration, if required.
User Level Admin
set config-to-factory-default
Syntax
132
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Keys and Certificates Commands
Keys and Certificates Commands
Netload
Description Loads certificates and keys into the IOLAN.
User Level Admin
netload https certificate|private-key <hostname/IP_address>
<filename>
Syntax
netload ldap certificate <hostname/IP_address> <filename>
netload ssh-client host <config_host> public-key ssh-1 rsa
<hostname/IP_address> <filename>
netload ssh-client host <config_host> public-key ssh-2 rsa|dsa
<hostname/IP_address> <filename>
netload ssh-client user <config_user> private-key ssh-1 rsa
<hostname/IP_address> <filename>
netload ssh-client user <config_user> private-key ssh-2 rsa|dsa
<hostname/IP_address> <filename>
netload ssh-server user <config_user> public-key ssh-2 rsa|dsa
<hostname/IP_address> <filename>
netload ipsec <config_tunnel_name> public-key rsa
<hostname/IP_address> <filename>
Options
https certificate|private-key
If you are using the secure version of the WebManager (HTTPS), then you need to
download the SSL/TLS private key and CA list to make a secure connection.
ldap certificate
If you are using LDAP authentication with TLS, you need to download the certificate of
the CA who signed the LDAP certificate to the IOLAN for authentication to work
properly.
ssh-client host
The public key for the host that is being authenticated by the IOLANs SSH server.
public-key ssh-1
Specify ssh-1 when you are using SSH version 1.
public-key ssh-2
Specify ssh-2 when you are using SSH version 2.
rsa|dsa
When downloading keys to the IOLAN, specify the authentication method used by the
key.
ssh-client user
The user that the SSH key is for.
ssh-server user
The user that the SSH key is for.
Administration Commands 133
Download from Www.Somanuals.com. All Manuals Search And Download.
Keys and Certificates Commands
ipsec <tunnel_name>
When you configure an IPsec tunnel with an Authentication Method of RSA
Signature, you need to download the RSA key from the remote VPN gateway to the
IOLAN for that specific tunnel.
<hostname/IP_address>
Enter the host or IP address that contains the certificate/key you are downloading to the
IOLAN. If you are using a host name, If you are using a host name, it must be resolved
in either the IOLAN’s Host Table or a DNS server.
<filename>
Enter the complete path and file name of the certificate/key you are downloading to the
IOLAN.
Netsave
Description Uploads certificates and keys from the IOLAN to a remote host using TFTP.
User Level Admin
netsave ssh-server public-key ssh-2 rsa|dsa <hostname/IP_address>
<filename>
Syntax
netsave ipsec public-key rsa <hostname/IP_address> <filename>
Options
rsa|dsa
When uploading SSH keys from the IOLAN, specify the SSH authentication method
used by the SSH key.
ipsec public-key rsa
When you configure an IPsec tunnel with an Authentication Method of RSA
Signature, you need to upload the RSA key from the IOLAN to the remote VPN
gateway host for that specific tunnel.
<hostname/IP_address>
The IP address or host name for where the SSH key you are uploading from the IOLAN
is going. If you are using a host name, it must be resolved in either the IOLAN’s Host
Table or a DNS server.
<filename>
The complete path and file name for the file you are uploading from the IOLAN (this
path should be relative to the default path of your TFTP server, which may or may not
allow drive letters).
134
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
MOTD Commands
MOTD Commands
Set MOTD
Description Specifies the server/file that contains the message of the day (MOTD) that is displayed
when users log into the IOLAN. You can also retrieve the MOTD from a local file (it
must already be downloaded to the IOLAN using the netload customapp-file
command); to do this, do not specify the host parameter.
User Level Normal, Admin
set motd [display on|off] [host <hostname> file <path_filename>]
set motd file <local_file>
Syntax
Options
display
When enabled, displays the Message of the Day to users who are logging into
WebManager or EasyPort Web. The default is off.
host
The host that the IOLAN will be getting the Message of the Day file from.
<path_filename>
The path and file name, relative to the default path of your TFTP server software, of the
file that contains a string that is displayed when a user connects to the IOLAN.
<local_file>
This is the name of a file already downloaded to the IOLAN. The contents of this file
will be used for the MOTD.
Show MOTD
Description Show the Message of the Day (MOTD) settings.
User Level Admin
show motd
Syntax
Administration Commands 135
Download from Www.Somanuals.com. All Manuals Search And Download.
MOTD Commands
136
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Statistics Commands
Chapter
8
8
This chapter defines all the CLI commands associated with configuring the IOLAN’s statistics
parameters.
Configuration Statistics
Show Netstat
Description Shows currently used TCP/UDP sockets/ports.
User Level Admin
show netstat [all] [listening] [tcp] [udp] [tcpv6] [updv6]
Syntax
Options
all
Displays all ports, including server (listening) ports; by default, listening ports are not
displayed.
listening
Displays server (listening) ports; by default, listening ports are not displayed.
tcp
Displays TCP port statistics.
udp
Displays UDP port statistics.
tcpv6
Displays TCPv6 port statistics.
udpv6
Displays UDPv6 port statistics.
Show Netstat Statistics
Description Shows protocol (IP/ICMP/TCP/UDP) counters.
User Level Admin
show netstat statistics [ip] [ipv6] [icmp] [icmpv6] [tcp] [udp]
Syntax
[udp6]
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
137
Download from Www.Somanuals.com. All Manuals Search And Download.
Run-Time Statistics
Show Modbus Statistics
Description Shows the Modbus statistics.
User Level Admin
show modbus statistics master-tcp line *|<number>
Syntax
show modbus statistics master-udp line *|<number>
show modbus statistics slave-tcp line *|<number>
show modbus statistics slave-udp line *|<number>
Show Routes
Description Shows current information about IPv4 or IPv6 network routes.
User Level Admin
show routes [ipv6]
Syntax
Run-Time Statistics
Delete Arp
Description Delete entries from the IOLAN's ARP cache. Takes effect immediately; not related to
configuration.
User Level Admin
delete arp
Syntax
Show Arp
Show Serial
Uptime
Description Shows the current contents of the ARP cache.
User Level Admin
show arp
Syntax
Description Shows statistics on the serial port.
User Level Admin
show serial [<line_number>]
Syntax
Description Displays the elapsed time (in days, hours, minutes, and seconds) since the last
reboot/power cycle.
User Level Admin
uptime
Syntax
138
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
IOLAN+ User
Commands
Chapter
9
9
You can configure the IOLAN using the IOLAN+ menu. See the IOLAN+ User’s Guide for the
command line interface and menu parameters. See IOLAN+ Interface in the IOLAN User’s Guide for
a list of changes to the IOLAN+ menu.
IOLAN+
Description Displays the IOLAN+ configuration menu.
User Level Admin
iolan+
Syntax
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
139
Download from Www.Somanuals.com. All Manuals Search And Download.
IOLAN+
140
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
I/O Commands
Chapter 10
10
This chapter defines all the CLI commands associated with configuring the IOLAN’s I/O parameters.
Global I/O Commands
Set IO UDP
Description Sets the UDP settings for I/O unicast messages.
User Level Admin
set io udp [mode on|off]
Syntax
[broadcast-interval <broadcast_interval>]
set io udp entry 1|2|3|4 disabled
set io udp entry 1|2|3|4 <udp_port> <start_ip> [<end_ip>]
Options
mode
Enables/disables UDP broadcast of I/O channel status (data).
broadcast-interval
Enter the interval, in seconds, for UDP broadcasts of I/O channel status (data). Valid
values are 1-9999. Default value is 30 seconds.
entry
You can specify up to four sets of UDP IP address that will receive the I/O unicast.
udp_port
The UDP port that the IOLAN will use to relay messages to servers/hosts.
start_ip
The first host IP address in the range of IP addresses (for IPV4 or IPV6) that the
IOLAN will listen for messages from and/or send messages to.
end_ip
The last host IP address in the range of IP addresses (for IPV4, not required for IPV6)
that the IOLAN will listen for messages from and/or send messages to.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
141
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Line
Set IO Failsafe
Description Sets the failsafe (watchdog) settings for I/O.
User Level Admin
set io failsafe [mode on|off] [timeout <seconds>]
Syntax
Options
mode
Enables/disables the Failsafe Timer. This is the global setting that must be enabled to
set the Failsafe Action on the channel for digital outputs and relays. When this timer
expires because of no I/O activity within the specified time interval, the Failsafe Action
set for the channel determines the action on the output.
timeout
The number of seconds that must elapse with no I/O activity before the channel
Failsafe Action is triggered. Valid values are 1-9999. The default is 30 seconds.
Set IO Modbus
Description Enabling the Modbus option makes the IOLAN act as a Modbus Slave, allowing
Modbus Masters to communicate with the IOLAN to control and/or retrieve I/O data.
User Level Admin
set io modbus [mode on|off] [uid <1-255>]
Syntax
Options
mode
Enables/disables Modbus as the communication protocol for all the I/O channels.
uid
This is the UID you are assigning to the IOLAN, which is acting as a Modbus slave.
Set IO Temperature-Scale
Description Sets the temperature scale that will be used for all I/O temperature readings.
User Level Admin
set io temperature-scale celsius|fahrenheit
Syntax
Option
temperature-scale
Select the temperature scale that will be used to display temperature data, either
Fahrenheit or Celsius. The default is Celsius.
Set Line
Set Line Service
Description Sets the Line Service settings for signal I/O. When the line service is set to signal-io,
you also have the option of enabling the I/O extension for the serial singal pins. See Set
User Level Admin
set line <number> service signal-io
Syntax
Option
signal-io
Sets the line to use signal I/O. You still need to define the serial pins for digital input
(CTS, DSR, or DCD) or digital output (RTS or DTR). See Set IOChannel Digital
page 147 for configuration options.
142
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel
Set IOChannel Mode
Description Sets general I/O channel settings for the specified channel, these settings are available
to all channels and I/O serial pins.
User Level Admin
set iochannel <i/o_channel> [mode enabled|disabled]
[description <string>]
Syntax
Options
i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
mode
Enables the channel, allowing the settings to become active.
description
Provide a description of the channel, making it easier to identify. The channel
description can be up to 20 characters.
Set IOChannel Digital I/O
Description Sets up the Digital I/O channel to act as either an output or input channel.
User Level Admin
set iochannel <digital_channel> source-type input|output
Syntax
Options
digital_channel
Specify the Digital channel number, for example, d2.
source-type
Specify whether the channel will drive the line (output) or will be reading the status of
the line (input). The default is Input. The internal jumpers must match the software
configuration, so if you change this setting to Output, you will have to also change the
internal hardware jumpers.
I/O Commands 143
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel Digital Input
Description Sets the Digital input settings for the channel.
User Level Admin
set iochannel <digital_channel>
Syntax
[alarm [trigger disabled|inactive-input|active-input]
[clear auto|manual] [email on|off] [syslog on|off]
[snmp on|off]]
[description <string>] [invert-signal on|off]
[latch disabled|inactive-to-active|active-to-inactive]
Options
digital_channel
Specify the Digital channel number, for example, d2.
alarm
Configures alarm settings when the Digital input trigger is activated.
trigger
When the trigger condition is met, triggers the specified alarm action. Triggers can be:
z
z
Disabled—No alarm settings. This is the default.
Inactive—When the expected Digital input is active, going inactive will trigger an
alarm.
z
Active—When the expected Digital input is inactive, going active will trigger an
alarm.
clear
Specify Manual to manually clear an alarm. Specify Auto to automatically clear the
alarm when the trigger condition changes; for example, if the Trigger is Inactive and
the alarm is triggered, once the input becomes active again, the alarm will be cleared
when Auto is set. The default is Auto.
email
Sends an email alert to an email account(s) set up in the Server settings (the Line Email
Alert settings are not used with this feature) when an alarm is triggered or cleared. The
email alert data includes the severity level and the value that caused the alarm to trigger
or clear. The Email Alert is associated with Level Critical.
syslog
Sends a message to syslog when an alarm is triggered or cleared. The syslog entry
includes the severity level and the value that caused the alarm to trigger or clear. The
syslog message is associated with Level Critical.
snmp
Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the
severity level and whether the alarm was triggered or cleared.
description
Provide a description of the channel, making it easier to identify. The channel
description can be up to 20 characters.
invert-signal
Inverts the actual condition of the I/O signal in the status; therefore, an inactive status
will be displayed as active.
latch
Latches (remembers) the activity transition (active-to-inactive or inactive-to-active).
The latched status is maintained until it is read. Once it is read, it will revert to the
current status. The default is disabled.
144
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel Digital Input (Serial Pins)
Description Sets the Digital input settings for serial pins CTS, DSR, and DCD. This option is only
available when the Line Service is set to Signal I/O.
User Level Admin
set iochannel cts|dsr|dcd
Syntax
[alarm [trigger disabled|inactive-input|active-input]
[clear auto|manual] [email on|off] [syslog on|off]
[snmp on|off]]
[description <string>] [invert-signal on|off]
[latch disabled|inactive-to-active|active-to-inactive]
Options
digital_channel
Specify the Digital channel number, for example, d2.
alarm
Configures alarm settings when the Digital input trigger is activated.
trigger
When the trigger condition is met, triggers the specified alarm action. Triggers can be:
z
z
Disabled—No alarm settings. This is the default.
Inactive—When the expected Digital input is active, going inactive will trigger an
alarm.
z
Active—When the expected Digital input is inactive, going active will trigger an
alarm.
clear
Specify Manual to manually clear an alarm. Specify Auto to automatically clear the
alarm when the trigger condition changes; for example, if the Trigger is Inactive and
the alarm is triggered, once the input becomes active again, the alarm will be cleared
when Auto is set. The default is Auto.
email
Sends an email alert to an email account(s) set up in the Server settings (the Line Email
Alert settings are not used with this feature) when an alarm is triggered or cleared. The
email alert data includes the severity level and the value that caused the alarm to trigger
or clear. The Email Alert is associated with Level Critical.
syslog
Sends a message to syslog when an alarm is triggered or cleared. The syslog entry
includes the severity level and the value that caused the alarm to trigger or clear. The
syslog message is associated with Level Critical.
snmp
Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the
severity level and whether the alarm was triggered or cleared.
description
Provide a description of the channel, making it easier to identify. The channel
description can be up to 20 characters.
invert-signal
Inverts the actual condition of the I/O signal in the status; therefore, an inactive status
will be displayed as active.
I/O Commands 145
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
latch
Latches (remembers) the activity transition (active-to-inactive or inactive-to-active).
The latched status is maintained until it is read. Once it is read, it will revert to the
current status. The default is disabled.
Set IOChannel Digital Output
Description Sets the Digital output channel settings.
User Level Admin
set iochannel <digital_channel>
Syntax
[type sink|source|sink-and-source] [active-signal-width <width>]
[inactive-signal-width <width>]
[failsafe-action none|activate-output|deactivate-output]
set iochannel <digital_channel>
output [pulse continuous|counted <pulse_count>]
[active-to-inactive-delay <delay>]
[inactive-to-active-delay <delay>]
Options
digital_channel
Specify the Digital channel number, for example, d2.
type
Specify the type of digital output:
z
z
z
Sink—Specifies that the channel will be grounded when active.
Source—Specifies that the channel will provide voltage when active.
Sink and Source—Specifies that channel will be grounded when it is inactive and
will provide voltage when it is active.
The default is Sink.
active-signal-width
How long the channel will be active during the pulse mode. Valid values are 1-9999 x
100 ms. The default is 100 ms.
inactive-signal-width
How long the channel will remain inactive during pulse mode. Valid values are 1-9999
x 100 ms. The default is 100 ms.
failsafe-action
When there has been no I/O activity within the specified time (set in the Global
Settings) and the Failsafe Timer is triggered, you can set the Failsafe Action to:
z
z
z
None—The state of the Digital/Relay output remains the same, no change.
Activate Output—Activates the channel.
Deactivate Output—Deactivates the channel.
146
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
output
Specify how the channel output will be handled:
z
z
Manual—You must manually manipulate the channel output.
Pulse—Activates and deactivates the channel output activity in intervals after it is
manually activated.
z
z
Inactive-to-Active Delay—The channel output will remain inactive for the
specified time interval after it is manually started.
Active-to-Inactive Delay—The channel output will go inactive after the specified
time interval after it is manually started.
The default is Manual.
pulse
When the Output is Pulse, you can have it pulse in a Continuous manner or specify a
pulse Count (each count consists of an active/inactive sequence). The default is
Continuous.
active-to-inactive-delay
When the I/O is commanded to an inactive state, this is the length of the delay before
the command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.
inactive-to-active-delay
When the I/O is commanded to an active state, this is the length of the delay before the
command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.
Set IOChannel Digital Output (Serial Pins)
Description Sets the Digital output for serial pins RTS and DTR. This option is only available when
the Line Service is set to Signal I/O.
User Level Admin
set iochannel rts|dtr [description <string>]
[failsafe-action none|activate-outut|deactivate-output]
[mode enabled|disabled]
Syntax
Options
description
Provide a description of the channel, making it easier to identify. The channel
description can be up to 20 characters.
failsafe-action
When there has been no I/O activity within the specified time (set in the Global
Settings) and the Failsafe Timer is triggered, you can set the Failsafe Action to:
z
z
z
None—The state of the Digital/Relay output remains the same, no change.
Activate Output—Activates the channel.
Deactivate Output—Deactivates the channel.
mode
Enables the channel, allowing the settings to become active.
I/O Commands 147
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel Relay
Description Sets the Relay output channel settings.
User Level Admin
set iochannel <relay_number> output
Syntax
[pulse continuous|counted <pulse_count>]
[active-to-inactive-delay <delay>]
[inactive-to-active-delay <delay>]
set iochannel <relay_number>
[active-signal-width <width>] [inactive-signal-width <width>]
[failsafe-action none|activate|deactivate]
Options
relay_number
Specify the Relay channel number, for example, r2.
output
Specify how the channel output will be handled:
z
z
Manual—You must manually manipulate the channel output.
Pulse—Activates and deactivates the channel output activity in intervals after it is
manually activated.
z
z
Inactive-to-Active Delay—The channel output will remain inactive for the
specified time interval after it is manually started.
Active-to-Inactive Delay—The channel output will go inactive after the specified
time interval after it is manually started.
The default is Manual.
pulse
When the Output is Pulse, you can have it pulse in a Continuous manner or specify a
pulse Count (each count consists of an active/inactive sequence). The default is
Continuous.
active-to-inactive-delay
When the I/O is commanded to an inactive state, this is the length of the delay before
the command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.
inactive-to-active-delay
When the I/O is commanded to an active state, this is the length of the delay before the
command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.
active-signal-width
How long the channel will be active during the pulse mode. Valid values are 1-9999 x
100 ms. The default is 100 ms.
inactive-signal-width
How long the channel will remain inactive during pulse mode. Valid values are 1-9999
x 100 ms. The default is 100 ms.
failsafe-action
When there has been no I/O activity within the specified time (set in the Global
Settings) and the Failsafe Timer is triggered, you can set the Failsafe Action to:
z
z
z
None—The state of the Digital/Relay output remains the same, no change.
Activate Output—Activates the channel.
Deactivate Output—Deactivates the channel.
148
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel Analog (True Analog)
Description Sets the Analog input channel settings.
User Level Admin
set iochannel <analog_channel> type current|voltage
range <range_specifier>
Syntax
set iochannel <analog_channel> alarm
[level 1|2|3|4|5 [mode on|off] [trigger-type disabled|low|high]
[trigger-level <decimal_value>] [clear-mode auto|manual]
[clear-level <decimal_value>] [email on|off] [snmp on|off]
[syslog on|off]]
Options
analog_channel
Specify the Analog channel number, for example, a2 or a4 (this also applies to
Temperature models).
type
Select the type of input being measured, either Current or Voltage. The default is
Current.
range
Select the range for the measurement type. For current, the range is:
z
z
0-20 (0-20mA) This is the default.
4-20 (04-20mA)
For voltage, the range is:
z
z
z
z
z
1 (+/-1V)
5 (+/-5V)
10 (+/-10V) This is the default.
150 (+/-150mV)
500 (+/-500mV)
alarm
Configures alarm settings when the Analog input trigger is activated.
level
You can specify up to five alarm trigger/clear severity levels. If the Trigger Type is
Low, an alarm is triggered when the input drops below the specified Trigger value;
other severity level trigger values must decrease in value with each subsequent level. If
the Trigger Type is High, an alarm is triggered when the input is higher than the
specified Trigger value; other severity level trigger values must increase in value with
each subsequent level. To clear an alarm, the input must drop below the specified value
when Trigger Type is High or go above the specified value when Trigger Type is Low.
mode
Enables/disables an alarm level. The default is off.
trigger-type
If the Trigger Type is Low, an alarm is triggered when the input drops below the
specified Trigger value; other severity level trigger values must decrease in value with
each subsequent level. If the Trigger Type is High, an alarm is triggered when the input
is higher than the specified Trigger value; other severity level trigger values must
increase in value with each subsequent level.
I/O Commands 149
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
trigger-level
Specify the value that will trigger an alarm, the measurement is based on the Type and
Range that you specify. This value must not fall within the scope of the value used to
clear an alarm.
clear-mode
Specifies whether an activated alarm must be Manually cleared, or can be cleared when
the input drops below the specified value (when Trigger Type is High) or goes above
the specified value (when Trigger Type is Low).
clear-level
Specify that value that will clear an alarm, the measurement is based on the Type and
Range that you specify. This value must not fall within the scope of the value used to
trigger an alarm.
email
Sends an email alert to an email account(s) set up in the Server settings (the Line Email
Alert settings are not used with this feature) when an alarm is triggered or cleared. The
email alert data includes the severity level and the value that caused the alarm to trigger
or clear. The Email Alert is associated with Level Critical.
snmp
Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the
severity level and whether the alarm was triggered or cleared.
syslog
Sends a message to syslog when an alarm is triggered or cleared. The syslog entry
includes the severity level and the value that caused the alarm to trigger or clear. The
syslog message is associated with Level Critical.
Set IOChannel Analog (Temperature)
Description Sets the Analog input channel settings for Temperature models.
User Level Admin
set iochannel <analog_channel> type rtd|thermocouple
range <range_specifier>
Syntax
set iochannel <analog_channel> alarm
[level 1|2|3|4|5 [mode on|off] [trigger-type disabled|low|high]
[trigger-level <decimal_value>] [clear-mode auto|manual]
[clear-level <decimal_value>] [email on|off] [snmp on|off]
[syslog on|off]]
Options
analog_channel
Specify the Analog channel number, for example, a2 or a4 (this also applies to
Temperature models).
type
Specify the type of sensor you are using to measure temperature, either RTD or
thermocouple. The default is RTD.
150
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
range
Specify the temperature range that you want to measure. For RTD, the range is:
z
z
z
z
z
z
z
z
z
z
z
z
z
1 (Pt100 a=385 -50 to 150C) This is the default.
2 (Pt100 a=385 0 to 100C)
3 (Pt100 a=385 0 to 200C)
4 (Pt100 a=385 0 to 400C)
5 (Pt100 a=385 -200 to 200C)
6 (Pt100 a=392 -50 to 150C)
7 (Pt100 a=392 0 to 100C)
8 (Pt100 a=392 0 to 200C)
9 (Pt100 a=392 0 to 400C)
10 (Pt100 a=392 -200 to 200C)
11 (Pt1000 a=385 -40 to 160C)
12 (NiFe604 a=518 -80 to 100C)
13 (NiFe604 a=518 0 to 100C)
For thermocouple, the range is:
z
z
z
z
z
z
z
b (B 500 to 1800C)
e (E 0 to 1000C)
j (J 0 to 760C) This is the default.
k (K 0 to 1370C)
r (R 500 to 1750C)
s (S 500 to 1750C)
t (T -100 to 400C).
alarm
Configures alarm settings when the Analog input trigger is activated.
level
You can specify up to five alarm trigger/clear severity levels. If the Trigger Type is
Low, an alarm is triggered when the input drops below the specified Trigger value;
other severity level trigger values must decrease in value with each subsequent level. If
the Trigger Type is High, an alarm is triggered when the input is higher than the
specified Trigger value; other severity level trigger values must increase in value with
each subsequent level. To clear an alarm, the input must drop below the specified value
when Trigger Type is High or go above the specified value when Trigger Type is Low.
mode
Enables/disables an alarm level. The default is off.
trigger-type
If the Trigger Type is Low, an alarm is triggered when the input drops below the
specified Trigger value; other severity level trigger values must decrease in value with
each subsequent level. If the Trigger Type is High, an alarm is triggered when the input
is higher than the specified Trigger value; other severity level trigger values must
increase in value with each subsequent level.
trigger-level
Specify the value that will trigger an alarm, the measurement is based on the Type and
Range that you specify. This value must not fall within the scope of the value used to
clear an alarm.
I/O Commands 151
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
clear-mode
Specifies whether an activated alarm must be Manually cleared, or can be cleared when
the input drops below the specified value (when Trigger Type is High) or goes above
the specified value (when Trigger Type is Low).
clear-level
Specify that value that will clear an alarm, the measurement is based on the Type and
Range that you specify. This value must not fall within the scope of the value used to
trigger an alarm.
email
Sends an email alert to an email account(s) set up in the Server settings (the Line Email
Alert settings are not used with this feature) when an alarm is triggered or cleared. The
email alert data includes the severity level and the value that caused the alarm to trigger
or clear. The Email Alert is associated with Level Critical.
snmp
Sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the
severity level and whether the alarm was triggered or cleared.
syslog
Sends a message to syslog when an alarm is triggered or cleared. The syslog entry
includes the severity level and the value that caused the alarm to trigger or clear. The
syslog message is associated with Level Critical.
Set IOChannel IOExtension
Description Configures the I/O extension options that allow you to connect the Digital Input
channel or input serial signal pin (when the line is configured for signal-io) to Digital
Output/Relay channels or output serial signal pins (when the line is configured for
signal-io) on the same IOLAN, remote IOLAN(s), and/or TCP/IP applications running
on local hosts.
User Level Admin
set iochannel <channel> ioextension enabled on|off
[keepalive on|off]
Syntax
set iochannel <channel> ioextension connection-method
client-initiated [tcp-port <tcp_port>] [multihost on|off]
set iochannel <channel> ioextension connection-method
server-initiated <host_name> [tcp-port <tcp_port>]
[multihost all|backup <config_backup_host> <host_port>|none]
set iochannel <channel> ioextension connection-method
local-connection [<input_channel>]
Options
<channel>
Specify the Digital/Relay channel or serial signal pin that you are configuring the I/O
extension for. The channel can be d1, d2, d3, d4, r1, r2, depending on the model. The
serial signal pins are dsr, dcd, or cts for input and dtr or rts for output.
152
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
enabled
When enabled, the digital input channel or DSR/DCD/CTS input serial signal pins can
be connected to:
z
A Digital output or relay (if the I/O model supports relay) channel on the same
IOLAN
z
z
Output Serial Signal Pins (DTR/RTS)
A Digital output channel on another IOLAN(s) or output serial signal pins
(DTR/RTS) on another IOLAN(s)
z
A TCP/IP application(s) running on a host on the network
When enabled, the digital output/relay channel or DTR/RTS output serial signal pins
can be associated with a digital input channel or input serial signal pins.
Default: Disabled
keepalive
Enables a per-connection TCP keepalive feature. After the configured number of
seconds, the connection will send a gratuitous ACK to the network peer, thus either
ensuring the connection stays active OR causing a dropped connection condition to be
recognized.
This parameter needs to be used in conjunction with server parameter,
monitor-connection-every. The interval determines how long the IOLAN will wait
during inactivity before "testing" the connection. It should be noted that if a network
connection is accidentally dropped, it can take as long as the specified interval before
anyone can reconnect to the serial port.
connection-method
The connection-method is one of the following:
z
z
z
Client-Initiated—When specified, the channel/serial signal pin will wait for
connections to be initiated by another I/O channel or a TCP/IP application.
Server-Initiated—When specified, the channel/serial signal pin initiates
communication to another I/O channel or a TCP/IP application.
Local-Connection—When specified, the input or output, depending on how the
channel or serial signal pin is configured, will be associated with another local
IOLAN I/O channel or serial signal pin.
When the channel is configured as digital input or when configuring an input serial
signal pin, the Output Channels parameter displays all the local digital output
signals or relays that it is associated with.
When the channel is configured as digital output, you must select a local digital
input channel or input serial signal pin on the IOLAN.
Note that the Failsafe Action is not compatible with the local-connection option.
Default: Client-Initiated
client-initiated tcp-port
The TCP port that the channel/serial signal pin will use to listen for incoming
connections.
Default: 2000 for channel 1, then increments by one for each channel
client-initiated multihost
When this option is enabled, multiple I/O channels and/or TCP/IP applications can
connect to this channel/serial signal pin. The default is off.
I/O Commands 153
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
server-initiated tcp-port
The TCP Port that the channel/serial signal pin will use to communicate to another
IOLAN or a TCP/IP application.
Default: 2000 for channel 1, then increments by one for each channel
server-initiated multihost all|backup <config_backup_host> <tcp_port>|none
Used for connections going from the Digital input channel or input serial signal pins,
allows the input channel/serial signal pin to communicate to either all the hosts in the
multihost list or a primary/backup host schema (see Configuring Multiple Hosts in the
IOLAN User’s Guide for a more detailed explanation).
local-connection <input_channel>
Specify the Digital input channel or input serial signal pin that will control the
Digital/Relay output channel or output serial signal pin.
Set IOChannel Multihost
Description Configures up to 49 hosts/IOLANs that the Digital input channel or input serial signal
pins (DSR, DCD, or CTS-when the line is configured for signal-io) will connect to. To
see a list of configured hosts/IOLANs, enter the show iochannel <channel>
command.
User Level Admin
set iochannel <channel> multihost entry <number> delete
Syntax
set iochannel <channel> multihost entry <number> host <host_name>
<tcp_port>
Options
<channel>
Specify the Digital input channel or input serial signal pin that will be connecting to all
the hosts/IOLANs in the multihost list.
entry
Specify the multihost table entry number. Valid values are 1-49.
delete
Deletes the entry number in the multihost table.
host
Specify the preconfigured host that will be in the multihost list.
Default: None
<tcp_port>
Specify the TCP port that the I/O channel or serial signal pin will use to communicate
to the Host.
Default: 0
154
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Set IOChannel
Set IOChannel IOExtension SSL
Description Configures the secure SSL/TLS connection between the Digital/Relay I/O channel or
serial signal pin and the host/IOLAN. For an explanation of the parameters, see Set SSL
User Level Admin
set iochannel <channel> ioextension ssl [enabled on|off]
[use-server on|off] [version any|tslv1|sslv3]
Syntax
[type client|server] [verify-peer on|off]
[validation-criteria country <code>|state-province <text>|
locality <text>|organisation <text>|organisation-unit <text>|
common-name <text>|email <email_addr>]
set iochannel <channel> ioextension ssl cipher-suite
option1|option2|option3|option4|option5
encryption any|aes|3des|des|arcfour|arctwo|none
min-key-size 40|56|64|128|168|256
max-key-size 40|56|64|128|168|256
key-exchange any|rsa|edh-rsa|edh-dss|adh
hmac any|sha1|md5
Show IOChannel Status
Description Shows the I/O channel status for all channels and the serial signal pins (when the line is
configured for signal-io).
User Level Admin
show iochannel status
Syntax
Kill IOChannel
Description Kills the I/O channel.
User Level Admin
kill iochannel <i/o_channel>
Syntax
kill iochannel line <number> rts|cts|dtr|dsr|dcd
Options
i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
rts|cts|dtr|dsr|dcd
Specify the Digital output pins (RTS or DTR) or Digital input pins (CTS, DSR, or
DCD).
I/O Commands 155
Download from Www.Somanuals.com. All Manuals Search And Download.
I/O Channel Control Commands
Show IO
Description Shows global I/O information (for example, UDP, TruePort, Modbus). Temperature I/O
is Analog.
User Level Admin
show iochannel <i/o_channel>
Syntax
show iochannel rts|cts|dtr|dsr|dcd
Options
i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
rts|cts|dtr|dsr|dcd
Specify the Digital output pins (RTS or DTR) or Digital input pins (CTS, DSR, or
DCD).
Show IOChannel
Description Shows I/O channel information. Temperature I/O is Analog.
User Level Admin
show iochannel <i/o_channel>
Syntax
show iochannel line <number> rts|cts|dtr|dsr|dcd
Options
i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
rts|cts|dtr|dsr|dcd
Specify the Digital output pins (RTS or DTR) or Digital input pins (CTS, DSR, or
DCD).
I/O Channel Control Commands
The I/O commands in this section are used to manually manage the I/O channels.
Digital Output
Description Manages the Digital output channel status. Not all models have four Digital channels,
most have just two.
User Level Admin
iochannel d1|d2|d3|d4|cts|dsr|dcd clear alarm|input-latch
Syntax
Options
alarm
Clears the alarm. Note that if the condition that tripped the alarm still exists, the alarm
will not look like it’s cleared, but will reflect the appropriate alarm level severity. Alarm
Level 0 means that the alarm has not been triggered.
latch-input
Clears the latch value.
156
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Calibrating Analog Input (Analog/Temperature)
Digital Input
Description Manages the Digital input channel status.
User Level Admin
iochannel d1|d2|d3|d4|rts|dtr output activate|deactivate
Syntax
Option
output
Manually activates/deactivates the I/O channel.
Relay
Description Manages the Relay output channel status.
User Level Admin
iochannel r1|r2 output activate|deactivate
Syntax
Option
output
Manually activates/deactivates the I/O channel.
Analog Input
Description Manages the Analog input channel status.
User Level Admin
iochannel a1|a2|a3|a4 clear alarm|min|max
Syntax
Options
alarm
Clears the alarm. Note that if the condition that tripped the alarm still exists, the alarm
will not look like it’s cleared, but will reflect the appropriate alarm level severity. Alarm
Level 0 means that the alarm has not been triggered.
min
Clears the minimum value.
max
Clears the maximum value.
Calibrating Analog Input (Analog/Temperature)
Calibrate Analog
Description Calibrates the Analog input channel. When this command is issued, a script will
automatically start, requesting that the minimum and maximum calibration values be
applied to the requested Analog/Temperature channel. See Calibrating Analog Input in
the IOLAN User’s Guide for more information.
User Level Admin
iochannel a1|a2|a3|a4 calibrate
Syntax
Reset Calibration
Description Resets the calibration to factory defaults.
User Level Admin
reset io calibration
Syntax
I/O Commands 157
Download from Www.Somanuals.com. All Manuals Search And Download.
Calibrating Analog Input (Analog/Temperature)
158
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Commands
Chapter 11
11
This chapter defines all the CLI commands associated with configuring the IOLAN’s power
parameters.
Power Commands
Description Actively controls the RPS plug power.
User Level Admin, Normal
power cycle line <number> [plug <number|range|*>]
Syntax
power on line <number> [plug <number|range|*>]
power off line <number> [plug <number|range|*>]
power reset line <number>
power status line <number>
Options
cycle
Turns the specified plug(s) off and then on.
on
Turns the specified plug(s) on.
off
Turns the specified plug(s) off.
reset
Resets all the RPS plugs to the default state as defined in the Power Management line
settings.
status
Displays the status (on/off) of the plug(s).
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
159
Download from Www.Somanuals.com. All Manuals Search And Download.
Power Commands
160
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
This chapter provides definitions for IOLAN terms.
BOOTP (BOOTstrap An Internet protocol that enables a diskless workstation to discover its own IP address, the IP
Protocol)
address of a BOOTP server on the network, and a file to be loaded into memory to boot the
machine. This enables the workstation to boot without requiring a hard or floppy disk drive.
Callback
A security feature where the IOLAN calls back the User at a predetermined number defined in
the Users account.
CHAP (Challenge
Handshake
Standard authentication protocol for PPP connections. It provides a higher level of security than
PAP and should be used whenever possible. see PAP
Authentication
Protocol)
Community (SNMP) An SNMP community is the group that devices and management stations running SNMP belong
to. It helps define where information is sent.
DHCP (Dynamic Host A TCP/IP protocol that provides static and dynamic address allocation and management.
Configuration
Protocol)
Direct Connection
Ethernet
Connections that bypass the IOLAN enabling the user to log straight into a specific host. A
direct connection is recommended where a user logging in to the IOLAN is not required.
A high-speed (10Mbps,100Mbps) cable technology that connects devices to a LAN, using one
or more sets of communication protocols.
Fixed Callback
A method where there is a specific number defined to callback a user.
Local Authentication Uses the user ID and password stored within the IOLAN User database.
LPD
Line Printer Daemon. A printer protocol that uses TCP/IP to establish connections between
printers and workstations on a network. The technology was developed originally for BSD
UNIX and has since become the de facto cross-platform printing protocol.
Modem Initialization A series of commands sent to the modem by a communications program at start up. These
String
commands tell a modem how to set itself up in order to communicate easily with another
modem.
MOTD
Multicast
Message of the day. This is defined by a file whose contents display when users log into the
IOLAN.
The broadcasting of messages to a specified group of workstations on a LAN, WAN, or internet.
NAK (Negative
Acknowledgment)
A communication control character sent by the receiving destination indicating that the last
message was not received correctly.
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7
161
Download from Www.Somanuals.com. All Manuals Search And Download.
PAP (Password
Authentication
Protocol)
Standard authentication protocol for PPP connections. see CHAP
RADIUS (Remote
Authentication Dial In
Users Services)
An open standard network security server that communicates with the PAP protocol.
Reverse Connection
RIP (Routing
Connections that originate from a host that go directly to a serial device through the IOLAN.
A protocol that allows gateways and hosts to exchange information about various routes to
Information Protocol) different networks.
Roaming Callback
RPC
A method where the client supplies the number for callback when they dial in.
Remote Procedure Call. A type of protocol that allows a program on one computer to execute a
program on a server computer.
Silent Connection
Silent connections are the same as direct connections except that they are permanently
established. The host login prompt is displayed on the screen. Logging out redisplays this
prompt. Silent connections, unlike direct connections, however, make permanent use of pseudo
tty resources and therefore consume host resources even when not in use.
SNMP (Simple
Network Management
Protocol)
A protocol for managing network devices.
Subnet/Prefix Bits
Identifies the devices IP address, which portion constitutes the network address and which
portion constitutes the host address.
162
IOLAN SDS/SCS/STS/MDC CLI Reference Guide, Version 3.7