NI PXI/PCI-5124 Specifications
12-Bit 200 MS/s Digitizer
This document lists the specifications for the NI PXI/PCI-5124 (NI 5124)
high-speed digitizer. Unless otherwise noted, these specifications are valid
for the following conditions:
•
•
•
All filter settings
All impedance selections
Sample clock set to 200 MS/s using onboard clock
Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5124 specifications, visit ni.com/manuals.
To access the NI 5124 documentation, including the NI High-Speed
of the NI 5124 signals, navigate to Start»All Programs»National
Instruments»NI-SCOPE»Documentation.
Hot Surface If the NI 5124 has been in use, it may exceed safe handling temperatures and
cause burns. Allow the NI 5124 to cool before removing it from the PXI chassis or PC.
Analog Input (Channel 0 and Channel 1) ........................................ 2
Front Panel Connector)................................................................. 17
CLK OUT (Sample Clock and Reference Clock Output,
Front Panel Connector)................................................................. 17
Trigger..................................................................................................... 17
Reference (Stop) Trigger ................................................................. 17
TRIG (External Trigger, Front Panel Connector)............................ 19
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Voltage Levels
Full Scale (FS)
Input Range and
Programmable
Vertical Offset
50 Ω
1 MΩ
—
Vertical
Range
Offset Range
(V)
Range
Vertical Offset
Range (V)
(Vpk-pk
)
(Vpk-pk
0.2
0.4
1
)
0.2
0.4
1
0.1
0.2
0.5
1
0.1
0.2
0.5
2
2
1
4
2
4
2
10
0
10
20
5
0
Maximum Input
Overload
50 Ω
1 MΩ
—
—
7 Vrms with |Peaks| ≤10 V
|Peaks| ≤42 V
Accuracy
Resolution
12 bits
DC Accuracy
(Programmable
Vertical
Range (Vpk-pk
0.2 and 0.4
)
NI PXI-5124
NI PCI-5124
Within 5 °C of
self-calibration
temperature
(0.65% of Input
+ 1.3 mV)
(0.65% of Input
+ 1.8 mV)
Offset = 0 V)
1 and 2
(0.65% of Input
+ 1.5 mV)
(0.65% of Input
+ 2.1 mV)
4, 10, and
20 (1 MΩ only)
(0.65% of Input
+ 10.0 mV)
(0.65% of Input
+ 10.0 mV)
Programmable
Vertical Offset
Accuracy
0.4% of offset setting
Within 5 °C of
self-calibration
temperature
© National Instruments Corporation
3
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
50 Ω and 1 MΩ
Comments
DC Drift
Range (Vpk-pk
)
—
0.2, 0.4, 1, and 2
(0.057% of Input + 0.006% of FS
+ 100 μV) per °C
4, 10, and
20 (1 MΩ only)
(0.057% of Input + 0.006% of FS
+ 900 µV) per °C
AC Amplitude
Accuracy
50 Ω
1 MΩ
Within 5 °C of
self-calibration
temperature
0.06 dB
( 0.7%) at 50 kHz
0.09 dB
( 1.0%) at 50 kHz
Crosstalk,
Typical
≤–85 dB at 10 MHz
CH 0 to/from
CH 1, External
Trigger to CH 0
or CH 1
Sparkle Code
Rate, Typical
<300 ppt* with onboard clock or 200 MHz external clock
<3 ppt* with 150 MHz external clock
Results based
on 2 × 1012
samples
0 with 100 MHz external clock
* ppt = parts per
trillion (1012)
Bandwidth and Transient Response
Bandwidth
(–3 dB)
Range (Vpk-pk
)
50 Ω
1 MΩ
Filters off
* 135 MHz
above 40 °C
All ranges
except 0.2
150 MHz
145 MHz up to
40 °C*
0.2
85 MHz
75 MHz
Rise/Fall Time,
Typical
Range (Vpk-pk
)
50 Ω and 1 MΩ
Filters off
All ranges
except 0.2
2.4 ns
0.2
3.3 ns
Bandwidth
Limit Filters
Noise Filter
Antialias Filter
Only one filter
can be enabled
at any given
time. The
20 MHz, typical
2-pole Bessel filter
60 MHz, typical
4-pole elliptical filter
antialias filter
is enabled by
default.
NI PXI/PCI-5124 Specifications
4
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
AC Coupling
Cutoff
(–3 dB)
12 Hz
AC coupling
available on
1 MΩ only
Passband
Flatness
Filter Settings
Filters Off
Range
Referenced
to 50 kHz
(Vpk-pk
)
50 Ω and 1 MΩ
All
0.5 dB DC to 20 MHz
1.0 dB 20 MHz to 50 MHz
ranges
except
0.2
1.7 dB 50 MHz to
100 MHz
0.2
0.6 dB DC to 20 MHz
1.5 dB 20 MHz to 40 MHz
Antialias
Filter On
All
ranges
–1.0 dB to +2.0 dB
DC to 55 MHz
2
1
0
–1
–2
–3
–4
–5
–6
–7
–8
–9
Antialias
Filter On
Filters
Off
Noise Filter On
–10
1 M
10 M
Frequency (Hz)
100 M
200 M
Figure 1. NI 5124 Frequency Response (Typical)
© National Instruments Corporation
5
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Spectral Characteristics
Spurious-Free
Dynamic Range
with Harmonics
(SFDR)
(Physical),
Typical
Range
Filters off
or antialias
filter on
(Vpk-pk
0.2
0.4
1
)
50 Ω
1 MΩ
70 dBc
70 dBc
70 dBc
70 dBc
67 dBc
60 dBc
60 dBc
75 dBc
75 dBc
72 dBc
72 dBc
65 dBc
65 dBc
—
10 MHz,
–1 dBFSinput
signal
Includes the
2nd through
the 5th
2
4
harmonics
10
20
Measured
from DC to
100 MHz on
NI PXI-5124
(1 MΩ only)
Measured
from 5 kHz to
100 MHz on
NI PCI-5124
Total Harmonic
Distortion
(THD), Typical
Range
Filters off
or antialias
filter on
(Vpk-pk
0.2
0.4
1
)
50 Ω
1 MΩ
–74 dBc
–74 dBc
–72 dBc
–72 dBc
–63 dBc
–63 dBc
—
–68 dBc
–68 dBc
–68 dBc
–67 dBc
–66 dBc
–58 dBc
–58 dBc
10 MHz,
–1 dBFSinput
signal
Includes the
2nd through
the 5th
2
4
harmonics
10
20
(1 MΩ only)
NI PXI/PCI-5124 Specifications
6
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Intermodulation
Distortion,
Typical
0.2 Vpk-pk to 2.0 Vpk-pk Ranges on 50 Ω Input
Filters off
or antialias
filter on
–75 dBc
Two tones at
10.2 MHz and
11.2 MHz
Each tone is
–7 dBFS
Signal-to-Noise
Ratio (SNR),
Typical
50 Ω
1 MΩ
Antialias
Excludes
harmonics
Range
Filters Antialias
Filters
Off
10 MHz,
–1 dBFSinput
signal
(Vpk-pk
)
Off
Filter On
56 dB
57 dB
58 dB
58 dB
—
Filter On
55 dB
57 dB
57 dB
57 dB
58 dB
0.2
0.4
1
57 dB
58 dB
58 dB
58 dB
—
53 dB
55 dB
57 dB
57 dB
56 dB
Measured
from DC to
100 MHz
2
4
Signal to Noise
and Distortion
(SINAD),
50 Ω
Filters Antialias
1 MΩ
Includes
harmonics
Range
Filters
Off
Antialias
Filter On
10 MHz,
–1 dBFSinput
signal
(Vpk-pk
)
Off
Filter On
56 dB
57 dB
58 dB
58 dB
—
Typical
0.2
0.4
1
57 dB
58 dB
58 dB
58 dB
—
53 dB
55 dB
57 dB
57 dB
56 dB
55 dB
57 dB
57 dB
57 dB
57 dB
Measured
from DC to
100 MHz
2
4
© National Instruments Corporation
7
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
9.83 MHz, –1 dBFS Input Signal
1 M
10 M
20 M
30 M
40 M
50 M
60 M
70 M
80 M
90 M
100 M
Frequency (Hz)
Figure 2. NI 5124 Dynamic Performance, 50 Ω, 1 Vpk-pk Range,
262,144 Point FFT (Typical)
NI PXI/PCI-5124 Specifications
8
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
50 Ω
Comments
RMS Noise
Range (Vpk-pk
0.2
)
1 MΩ
Noise filter on
50 Ω
NI PXI-5124:
94 μVrms
(0.047% FS)
NI PXI-5124:
104 μVrms
(0.052% FS)
terminator
connected
to input
NI PCI-5124:
106 μVrms
(0.053% FS)
NI PCI-5124:
116 μVrms
(0.058% FS)
0.4
1
188 μVrms
192 μVrms
(0.047% FS)
(0.048% FS)
470 μVrms
(0.047% FS)
480 μVrms
(0.048% FS)
2
940 μVrms
(0.047% FS)
960 μVrms
(0.048% FS)
4
1.88 mVrms
1.92 mVrms
(0.047% FS)
(0.048% FS)
10
4.7 mVrms
4.8 mVrms
(0.047% FS)
(0.048% FS)
20
—
9.4 mVrms
(1 MΩ only)
(0.047% FS)
© National Instruments Corporation
9
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
50 Ω
Comments
RMS Noise
Range (Vpk-pk)
1 MΩ
Antialias
filter on
0.2
NI PXI-5124:
112 μVrms
(0.056% FS)
NI PXI-5124:
130 μVrms
(0.065% FS)
50 Ω
terminator
connected
to input
NI PCI-5124:
126 μVrms
(0.063% FS)
NI PCI-5124:
146 μVrms
(0.073% FS)
0.4
1
200 μVrms
216 μVrms
(0.05% FS)
(0.054% FS)
500 μVrms
(0.05% FS)
510 μVrms
(0.051% FS)
2
1.0 mVrms
1.02 mVrms
(0.05% FS)
(0.051% FS)
4
2.04 mVrms
2.16 mVrms
(0.051% FS)
(0.054% FS)
10
5.1 mVrms
5.2 mVrms
(0.051% FS)
(0.052% FS)
20
N/A
10.2 mVrms
(1 MΩ only)
(0.051% FS)
NI PXI/PCI-5124 Specifications
10
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
50 Ω
Comments
RMS Noise
Range (Vpk-pk
0.2
)
1 MΩ
Filters off
50 Ω
NI PXI-5124:
114 μVrms
(0.057% FS)
NI PXI-5124:
164 μVrms
(0.082% FS)
terminator
connected
to input
NI PCI-5124:
128 μVrms
(0.064% FS)
NI PCI-5124:
184 μVrms
(0.092% FS)
0.4
1
204 μVrms
264 μVrms
(0.051% FS)
(0.066% FS)
510 μVrms
(0.051% FS)
550 μVrms
(0.055% FS)
2
1.02 mVrms
1.08 mVrms
(0.051% FS)
(0.054% FS)
4
2.08 mVrms
2.6 mVrms
(0.052% FS)
(0.065% FS)
10
20
5.2 mVrms
(0.052% FS)
5.5 mVrms
(0.055% FS)
—
10.6 mVrms
(0.053% FS)
© National Instruments Corporation
11
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
60 n
55 n
50 n
45 n
40 n
35 n
30 n
25 n
20 n
15 n
10 n
5 n
1 n
1 k
10 k
100 k
1 M
10 M
100 M
Frequency (Hz)
Figure 3. Representation of NI 5124 Spectral Noise Density on 0.2 V Range,
Noise Filter Enabled, 1 MΩ Input Impedance
–145.0
–147.5
–150.0
–152.5
1 k
10 k
100 k
1 M
10 M
100 M
Frequency (Hz)
Figure 4. Representation of NI 5124 Spectral Noise Density on 0.2 V Range,
Full Bandwidth, 50 Ω Input Impedance
NI PXI/PCI-5124 Specifications
12
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Horizontal
Sample Clock
Specification
Value
Comments
* Internal
Sources
NI PXI-5124
NI PCI-5124
Sample Clock is
locked to the
ReferenceClock
or derived from
the onboard
Internal, Onboard Clock
(internal VCXO)*
Internal, Onboard Clock
(internal VCXO)*
External, CLK IN (front
panel SMB connector)
External, CLK IN (front
panel SMB connector)
VCXO
External,
PXI Star Trigger
(backplane connector)
Onboard Clock (Internal VCXO)
Sample Rate
Range
Real-Time Sampling
Random Interleaved
Sampling (RIS)
* Divide by
n decimation
used for all rates
less than
(Single Shot)
3.052 kS/s to 200 MS/s*
400 MS/s to 4 GS/s in
multiples of 200 MS/s
200 MS/s
For more
information
about Sample
Clock and
decimation,
refer to the
NI High-Speed
Digitizers Help.
Phase Noise
Density, Typical
<–100 dBc/Hz at 100 Hz
<–120 dBc/Hz at 1 kHz
<–130 dBc/Hz at 10 kHz
10 MHz input
signal
© National Instruments Corporation
13
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
≤1 ps rms (100 Hz to 100 kHz)
≤2 ps rms (100 Hz to 1 MHz)
Comments
Sample Clock
Jitter, Typical
Includes the
effects of
the converter
aperture
uncertainty and
the clock
circuitry jitter
Excludes trigger
jitter
Timebase
Frequency
200 MHz
—
Timebase
Accuracy
Not Phase-Locked to
Reference Clock
Phase-Locked to
Reference Clock
—
25 ppm
Equal to the Reference
Clock accuracy
Sample Clock
Delay Range
1 Sample Clock period
—
—
Sample Clock
Delay/Adjustment
Resolution
≤5 ps
NI PXI/PCI-5124 Specifications
14
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
External Sample Clock
Sources
Value
Comments
NI PXI-5124
NI PCI-5124
—
CLK IN (front panel
SMB connector)
CLK IN (front panel SMB
connector)
PXI Star Trigger
(backplane connector)
Frequency
Range
50 MHz to 210 MHz (CLK IN)
Divide by
n decimation
available where
1 ≤ n ≤ 65,535
50 MHz to 80 MHz (PXI Star Trigger)
For more
information
about Sample
Clock and
decimation,
refer to the
NI High-Speed
Digitizers Help.
Duty Cycle
Tolerance
45% to 55%
—
Exported
NI PXI-5124
NI PCI-5124
—
Reference Clock
Destinations
CLK OUT (front panel
SMB connector)
CLK OUT (front panel
SMB connector)
PFI<0..1> (front panel
9-pin mini-circular
DIN connector)
PFI<0..1> (front panel
9-pin mini-circular
DIN connector)
PXI_Trig<0..7>
RTSI<0..7>
(backplane connector)
© National Instruments Corporation
15
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Sample Clock Exporting
Exported Sample
Clock Destinations
* Decimated
Sample Clock
only
Maximum
Frequency
Destination
CLK OUT (front panel
SMB connector)
210 MHz
PXI_Trig<0..6>
20 MHz
25 MHz
20 MHz
(backplane connector)*
PFI<0..1> (front panel 9-pin
mini-circular DIN connector)*
RTSI<0..6>*
Phase-Locked Loop (PLL) Reference Clock
Specification
Sources
Value
Comments
NI PXI-5124
PXI_CLK10
NI PCI-5124
—
RTSI 7
CLK IN (front panel SMB
(backplane connector)
CLK IN (front panel SMB connector)
connector)
Frequency
Range
1 MHz to 20 MHz in 1 MHz increments.
Default of 10 MHz.
—
The PLL Reference Clock frequency must be accurate
to 50 ppm.
Duty Cycle
Tolerance
45% to 55%
—
—
Exported
NI PXI-5124
NI PCI-5124
Reference Clock
Destinations
CLK OUT (front panel
SMB connector)
CLK OUT (front panel
SMB connector)
PFI<0..1> (front panel
9-pin mini-circular
DIN connector)
PFI<0..1> (front panel
9-pin mini-circular
DIN connector)
PXI_Trig<0..6>
RTSI<0..7>
(backplane connector)
NI PXI/PCI-5124 Specifications
16
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
CLK IN (Sample Clock and Reference Clock Input,
Front Panel Connector)
Specification
Value
Comments
Input Voltage
Range
Sine wave: 0.65 Vpk-pk to 2.8 Vpk-pk (0 dBm to 13 dBm)
Square wave: 0.2 Vpk-pk to 2.8 Vpk-pk
—
Maximum Input
Overload
7 Vrms with |Peaks| ≤10 V
—
Impedance
Coupling
50 Ω
—
—
AC
CLK OUT (Sample Clock and Reference Clock Output,
Front Panel Connector)
Specification
Output Impedance
Logic Type
Value
Comments
50 Ω
—
—
—
3.3 V CMOS
48 mA
Maximum Drive
Current
Trigger
Reference (Stop) Trigger
Specification
Value
Comments
Trigger Types
and Sources
Types
Sources
Refer to the
following
Edge, Window, Hysteresis,
Video, Digital, Immediate,
and Software
CH 0, CH 1, TRIG,
sections and the
NI High-Speed
Digitizers
Help for more
informationabout
what sources are
available for each
trigger type.
PXI_Trig<0..6>, PFI<0..1>,
PXI Star Trigger, Software,
and RTSI<0..6>
© National Instruments Corporation
17
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Time
Resolution
TDC
On
Onboard Clock
External Clock
N/A
TDC = Time
to Digital
Conversion
Circuit
50 ps
Off
5 ns
TDC
External Clock Period
Rearm Time
10 μs
Rearm Time
Holdoff
Holdoff set to 0
On
Off
2 μs
TDC
On
Onboard Clock
External Clock
N/A
—
10 μs to 85.899 s
Off
2 μs to 85.899 s
200 × (External Clock
Period) to
(232 – 1) × (External Clock
Period)
Analog Trigger (Edge, Window, and Hysteresis Trigger Types)
Sources
CH 0 (front panel BNC connector)
CH 1 (front panel BNC connector)
TRIG (front panel BNC connector)
—
—
Trigger Level
Range
CH 0, CH 1
100% FS
TRIG (External Trigger)
5 V
Trigger Level
Resolution
10 bits (1 in 1,024)
—
—
Edge Trigger
Sensitivity
CH 0, CH 1
TRIG (External Trigger)
3.5% FS up to 50 MHz,
increasing to 10% FS at
150 MHz
0.25 Vpk-pk up to 100 MHz,
increasing to 1 Vpk-pk at
200 MHz
Level
Accuracy,
Typical
CH 0, CH 1
TRIG (External Trigger)
0.35 V up to 10 MHz
—
4.7% FS up to 10 MHz
Trigger
Jitter
≤80 ps rms
Within 5 °C of
self-calibration
temperature
NI PXI/PCI-5124 Specifications
18
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Specification
Value
Comments
Trigger
Filters
Low-Frequency
(LF) Reject
High-Frequency
(HF) Reject
—
50 kHz
50 kHz
Digital Trigger (Digital Trigger Type)
Sources NI PXI-5124
PXI_Trig<0..6>
NI PCI-5124
—
RTSI<0..6>
(backplane connector)
PFI<0..1>
PFI<0..1>
(front panel SMB connector)
(front panel SMB connector)
PXI Star Trigger
(backplane connector)
Video Trigger (Video Trigger Type)
Sources
CH 0 (front panel BNC connector)
CH 1 (front panel BNC connector)
—
—
—
TRIG (front panel BNC connector)
Specific Line
Types
Any Line
Specific Field
Standard
Negative sync of NTSC, PAL, or SECAM signal
TRIG (External Trigger, Front Panel Connector)
Specification
Connector
Value
Comments
BNC
—
—
Impedance
Coupling
1 MΩ in parallel with 22 pF
AC, DC
12 Hz
—
—
AC-Coupling Cutoff
(–3 dB)
Input Voltage Range
5 V
—
—
Maximum Input Overload |Peaks| ≤42 V
© National Instruments Corporation
19
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
PFI 0 and PFI 1 (Programmable Function Interface,
AUX Front Panel Connector)
Specification
Connector
Value
Comments
9-pin mini-circular DIN
Bi-directional
—
—
Direction
As an Input (Trigger)
Destinations
Start Trigger (Acquisition Arm)
Reference (Stop) Trigger
Arm Reference Trigger
Advance Trigger
150 kΩ
—
Input Impedance
—
—
—
—
VIH
VIL
2.0 V
0.8 V
Maximum Input
Overload
–0.5 V, 5.5 V
Maximum
Frequency
25 MHz
—
—
As an Output (Event)
Sources
Start Trigger (Acquisition Arm)
Reference (Stop) Trigger
End of Record
Done (End of Acquisition)
Probe Compensation (1 kHz, 50% duty cycle
square wave, PFI 1 only)
Output Impedance
Logic Type
50 Ω
—
—
—
3.3 V CMOS
24 mA
Maximum Drive
Current
Maximum
Frequency
25 MHz
—
NI PXI/PCI-5124 Specifications
20
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
TClk Specifications
National Instruments TClk synchronization method and the NI-TClk driver
are used to align the sample clocks on any number of SMC-based modules
in a chassis. For more information about TClk synchronization, refer to the
NI-TClk Synchronization Help, which is located within the NI High-Speed
Digitizers Help.
•
Specifications are valid for any number of modules installed in one
NI PXI-1042 chassis.
•
•
•
All parameters set to identical values for each SMC-based module.
Sample Clock set to 200 MS/s and all filters are disabled.
For other configurations, including multichassis systems, contact
NI Technical Support at ni.com/support.
Note Although you can use NI-TClk to synchronize nonidentical modules, these
specifications apply only to synchronizing identical modules.
Specification
Value
Comments
Intermodule SMC Synchronization Using NI-TClk for Identical Modules (Typical)
Skew
500 ps
Caused by clock and analog
path delay differences
No manual adjustment
performed
Skew After Manual <10 ps
Adjustment
For information about
manual adjustment, refer to
the Synchronization
Repeatability Optimization
topic in the NI-TClk
Synchronization Help.
For additional help with the
adjustment process, contact
NI Technical Support at
ni.com/support.
Sample Clock
Delay/Adjustment
Resolution
≤5 ps
—
© National Instruments Corporation
21
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Waveform Specifications
Specification
Value
8 MB per channel standard
Comments
Onboard
* NI PXI-5124 only
Memory Size
(4 megasamples per channel)
32 MB per channel option
(16 megasamples per channel)
256 MB per channel option
(128 megasamples per channel)
512 MB per channel option
(256 megasamples per channel)*
Minimum
1 Sample
—
Record Length
Number of
Pretrigger
Samples
Zero up to full Record Length
Single-record mode
and multiple-record
mode
Number of
Posttrigger
Samples
Zero up to full Record Length
Single-record mode
and multiple-record
mode
Maximum
Number of
Records in
Onboard
8 MB/channel
21,845
* NI PXI-5124 only
† It is possible
to exceed these
numbers if you fetch
records while
32 MB/channel
256 MB/channel
512 MB/channel*
87,381
100,000†
100,000†
Memory
acquiring data.
For more
information, refer to
the NI High-Speed
Digitizers Help.
Allocated
Onboard
Memory per
Record
(Record Length × 2 bytes/S) + 200 bytes, rounded up to
—
next multiple of 128 bytes
or
384 bytes, whichever is greater
NI PXI/PCI-5124 Specifications
22
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Calibration
Specification
Value
Comments
Self-Calibration
Self-calibration is done on software command.
The calibration corrects for gain, offset, frequency
response, triggering, and timing adjustment errors
for all input ranges.
—
External Calibration
(Factory Calibration)
The external calibration calibrates the VCXO and the
voltage reference. Appropriate constants are stored
in nonvolatile memory.
—
Interval for External
Calibration
2 years
—
—
Warm-Up Time
15 minutes
Power
Specification
Typical Value
Comments
NI PXI-5124
1.3 A
NI PCI-5124
1.3 A
—
+3.3 VDC
+5 VDC
1.7 A
2.7 A
+12 VDC
–12 VDC
Total Power
130 mA
270 mA
17.6 W
130 mA
0 A
19.4 W
© National Instruments Corporation
23
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Software
Specification
Value
Comments
Driver
NI-SCOPE 2.7 or later
—
Software
NI-SCOPE is an IVI-compliant driver that allows you to
configure, control, and calibrate the NI 5124. NI-SCOPE
provides application programming interfaces for many
development environments.
Application
Software
NI-SCOPE provides programming interfaces,
documentation, and examples for the following
application development environments:
—
•
•
•
•
•
LabVIEW
LabWindows™/CVI™
Measurement Studio
Microsoft Visual C/C++
Microsoft Visual Basic
Interactive
Soft Front
Panel and
The Scope Soft Front Panel supports interactive control of
the NI 5124. The Scope Soft Front Panel is included on the
NI-SCOPE CD.
—
Configuration
National Instruments Measurement & Automation Explorer
(MAX) also provides interactive configuration and test tools
for the NI 5124. MAX is included on the NI-SCOPE CD.
NI PXI/PCI-5124 Specifications
24
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Environment
NI PXI-5124
Note To ensure that the NI PXI-5124 cools effectively, follow the guidelines in the
Maintain Forced Air Cooling Note to Users included in the NI PXI-5124 kit. The
NI PXI-5124 is intended for indoor use only.
Specification
Value
Comments
Operating
Temperature
0 ºC to +55 ºC in all NI PXI chassis except the following:
0 ºC to +45 ºC when installed in an NI PXI-1000/B or
PXI-101x chassis
—
Meets IEC-60068-2-1 and IEC-60068-2-2
Storage
Temperature
–40 ºC to +71 ºC
Meets IEC-60068-2-1 and IEC-60068-2-2
—
—
—
—
Operating Relative
Humidity
10% to 90%, noncondensing
Meets IEC-60068-2-56
Storage Relative
Humidity
5% to 95%, noncondensing
Meets IEC-60068-2-56
Operating Shock
Storage Shock
30 g, half-sine, 11 ms pulse
Meets IEC-60068-2-27
Test profile developed in accordance with
MIL-PRF-28800F
50 g, half-sine, 11 ms pulse
Meets IEC-60068-2-27
—
Test profile developed in accordance with
MIL-PRF-28800F
Operating Vibration 5 Hz to 500 Hz, 0.31 grms
Meets IEC-60068-2-64
—
—
Storage Vibration
5 Hz to 500 Hz, 2.46 grms
Meets IEC-60068-2-64
Test profile exceeds requirements of MIL-PRF-28800F,
Class B
Altitude
2,000 m maximum (at 25 °C ambient temperature)
2
—
—
Pollution Degree
© National Instruments Corporation
25
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
NI PCI-5124
Note To ensure that the NI PCI-5124 cools effectively, make sure that the chassis in which
it is used has active cooling that provides at least some airflow across the PCI card cage.
To maximize airflow and extend the life of the device, leave any adjacent PCI slots empty.
Refer to the Maintain Forced Air Cooling Note to Users included in the NI PCI-5124 kit
for important cooling information. The NI PCI-5124 is intended for indoor use only.
Specification
Operating
Value
Comments
0 ºC to +45 ºC
—
Temperature
Meets IEC-60068-2-1 and IEC-60068-2-2
Storage
Temperature
–40 ºC to +71 ºC
Meets IEC-60068-2-1 and IEC-60068-2-2
—
—
—
—
Operating Relative
Humidity
10% to 90%, noncondensing
Meets IEC-60068-2-56
Storage Relative
Humidity
5% to 95%, noncondensing
Meets IEC-60068-2-56
Storage Shock
50 g, half-sine, 11 ms pulse
Meets IEC-60068-2-27
Test profile developed in accordance with
MIL-PRF-28800F
Storage Vibration
5 Hz to 500 Hz, 2.46 grms
—
Meets IEC-60068-2-64
Test profile exceeds requirements of MIL-PRF-28800F,
Class B
Altitude
2,000 m maximum (at 25 °C ambient temperature)
2
—
—
Pollution Degree
NI PXI/PCI-5124 Specifications
26
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety, Electromagnetic Compatibility,
and CE Compliance
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control, and
laboratory use:
•
•
IEC 61010-1, EN 61010-1
UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or visit ni.com/
certification, search by model number or product line, and click the appropriate link
in the Certification column.
Electromagnetic Compatibility
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
•
•
•
EN 61326 EMC requirements; Minimum Immunity
EN 55011 Emissions; Group 1, Class A
CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note For EMC compliance, operate this device with RG223/U or equivalent shielded
cable. Operate according to product documentation
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
•
•
2006/95/EC; Low-Voltage Directive (safety)
2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note Refer to the Declaration of Conformity (DoC) for this product for any additional
regulatory compliance information. To obtain the DoC for this product, visit ni.com/
certification, search by model number or product line, and click the appropriate link
in the Certification column.
© National Instruments Corporation
27
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
Environmental Management
National Instruments is committed to designing and manufacturing
products in an environmentally responsible manner. NI recognizes that
eliminating certain hazardous substances from our products is beneficial
not only to the environment but also to NI customers.
For additional environmental information, refer to the NI and the
Environment Web page at ni.com/environment. This page contains the
environmental regulations and directives with which NI complies, as well
as any other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of their life cycle, all products must be sent to a WEEE recycling
center. For more information about WEEE recycling centers and National Instruments
WEEE initiatives, visit ni.com/environment/weee.htm.
˅
RoHS
Ёᅶ᠋
݇Ѣ
DŽ
National Instruments
National Instruments
(RoHS)
Ё
ড়㾘ᗻֵᙃˈ䇋ⱏᔩ ni.com/environment/rohs_chinaDŽ
RoHS
ni.com/environment/rohs_china
(For information about China RoHS compliance, go to
.)
Physical
Front Panel Connectors
Label
CH 0
Function
Connector Type
Analog Input
Analog Input
External Trigger
BNC female
BNC female
BNC female
CH 1
TRIG
CLK IN
Sample Clock Input and Reference SMB jack
Clock Input
CLK OUT
AUX I/O
Sample Clock Output and
Reference Clock Output
SMB jack
PFI 0, PFI 1
9-pin mini-circular DIN
NI PXI/PCI-5124 Specifications
28
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
NI PXI-5124 Front Panel Indicators
Label
Function
For more
information,
refer to the
NI High-Speed
Digitizers
Help.
ACCESS
The ACCESS LED indicates the status of the PCI bus and the
interface from the NI PXI-5124 to the controller.
ACTIVE
The ACTIVE LED indicates the status of the onboard
acquisition hardware of the NI PXI-5124.
Dimensions and Weight
NI PXI-5124
Dimensions
3U, One slot, PXI/cPCI Module
21.6 × 2.0 × 13.0 cm
(8.5 × 0.8 × 5.1 in.)
2.0 cm
(0.8 in.)
13.0 cm
(5.1 in.)
21.6 cm
(8.5 in.)
Weight
383 g (13.5 oz)
© National Instruments Corporation
29
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
NI PCI-5124
Dimensions
35.5 × 2.0 × 11.3 cm
(14.0 × 0.8 × 4.4 in.)
2.0 cm
(0.8 in.)
11.3 cm
(4.4 in.)
35.5 cm
(14.0 in.)
Weight
455 g (16 oz)
NI PXI/PCI-5124 Specifications
30
ni.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Where to Go for Support
The National Instruments Web site is your complete resource for technical
support. At ni.com/support you have access to everything from
troubleshooting and application development self-help resources to email
and phone assistance from NI Application Engineers.
A Declaration of Conformity (DoC) is our claim of compliance with the
Council of the European Communities using the manufacturer’s
declaration of conformity. This system affords the user protection for
electronic compatibility (EMC) and product safety. You can obtain the DoC
for your product by visiting ni.com/certification. If your product
supports calibration, you can obtain the calibration certificate for your
product at ni.com/calibration.
National Instruments corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504.
National Instruments also has offices located around the world to help
address your support needs. For telephone support in the United States,
create your service request at ni.com/support and follow the calling
instructions or dial 512 795 8248. For telephone support outside the United
States, contact your local branch office:
Australia 1800 300 800, Austria 43 662 457990-0,
Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,
Canada 800 433 3488, China 86 21 5050 9800,
Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,
Finland 358 (0) 9 725 72511, France 01 57 66 24 24,
Germany 49 89 7413130, India 91 80 41190000, Israel 972 3 6393737,
Italy 39 02 413091, Japan 81 3 5472 2970, Korea 82 02 3451 3400,
Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710,
Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60,
Poland 48 22 3390150,Portugal 351 210 311 210,Russia 7 495 783 6851,
Singapore 1800 226 5886, Slovenia 386 3 425 42 00,
South Africa 27 0 11 805 8197, Spain 34 91 640 0085,
Sweden 46 (0) 8 587 895 00, Switzerland 41 56 2005151,
Taiwan 886 02 2377 2222, Thailand 662 278 6777,
Turkey 90 212 279 3031, United Kingdom 44 (0) 1635 523545
© National Instruments Corporation
31
NI PXI/PCI-5124 Specifications
Download from Www.Somanuals.com. All Manuals Search And Download.
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation.
Refer to the Terms of Use section on ni.com/legal for more information about National
Instruments trademarks. Other product and company names mentioned herein are trademarks or trade
names of their respective companies. For patents covering National Instruments products, refer to the
appropriate location: Help»Patents in your software, the patents.txt file on your CD, or
ni.com/patents.
© 2004–2007 National Instruments Corporation. All rights reserved.
371135F-01
Aug07
Download from Www.Somanuals.com. All Manuals Search And Download.
|