Multi Link Cordless Telephone ML 001 User Manual

®
Home Smart Center  
MODEL: ML-001 / ML-100  
TM  
CUSTOMER SERVICE  
17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3  
Tel : (905) 456-8883  
PATENTED  
©2011 SKYLINK GROUP  
Fax : (905) 456-7819  
P/N. 101Z379-001  
FEB, 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
When using your telephone equipment, basic safety precautions should  
always be followed to reduce the risk of fire, electric shock and injury to  
persons, including the following:  
1. Do not use this product near water, for example, near a bath tub, wash  
bowl, kitchen sink or laundry tub, in a wet basement or near a swimming  
pool.  
2. Avoid using a telephone (other than a cordless type) during an  
electrical storm. There may be a remote risk of electric shock from  
lightning.  
3. Do not use the telephone to report a gas leak in the vicinity of the leak.  
4. Use only the power cord and batteries indicated in this manual. Do not  
dispose of batteries in a fire. They may explode. Check with local codes  
for possible special disposal instructions.  
5. Plug the adaptor to the socket-outlet that near the equipment and  
shall be easily accessible.  
SAVE THESE INSTRUCTIONS  
Attention  
This product is not an alarm system providing facilities to summon  
assistance, for use by persons who can be considered to be living  
at risk. This product is not intended to for use in health care signaling  
equipment or directly connect to central-station (Police, Medical, Fire).  
1–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IC Statement  
Declaration of Conformity  
‘’This product meets the applicable Industry Canada technical  
specifications.”  
Application of Council Directive(s) :  
Radio Equipment and Telecommunication Terminal Equipment  
Directive (1999/5/EC) - R&TTE  
Before installing this equipment, users should ensure that it is permissible  
to be connected to the facilities of the local telecommunications com-  
pany. The equipment must also be installed using an acceptable method  
of connection. In some cases, the company’s inside wiring associated  
with a single line individual service may be extended by means of a  
certified connector assembly (telephone extension cord). The customer  
should be aware that compliance with the above conditions may not  
prevent degradation of service in some situations.  
Standard(s) to which Conformity is Declared:  
EMC:  
EN 55022:1998+A1: 2000, EN 610000-3-2: 2000,  
EN 61000-3.3: 1995 +A1:2001, EN 55024: 1998+A1: 2001,  
EN 50130-4: 1995/A1: 1998, EN 300220-3: 2000,  
EN 301489-3: 2002  
Safety:  
Repairs to certified equipment should be made by an authorized Canadian  
maintenance facility designated by the supplier. Any repairs or alterations  
made by the user to this equipment, or equipment malfunctions, may give  
the telecommunications company cause to request the user to disconnect  
the equipment.  
EN 60950-1: 2001, EN 50371: 2002  
Telephony:  
TBR 21: 1998  
Manufacturer’s Name:  
Capital Prospect Limited  
..........................................................................................  
Users should ensure for their own protection that the electrical ground  
connections of the power utility, telephone lines and internal metallic water  
pipe system, if present, are connected together. This precaution may be  
particularly important in rural areas.  
Manufacturer’s Address:  
Room 3, 13/F, Block B, Veristrong Industrial Centre,  
..........................................................................................  
36 Au Pui Wan Street, Fo Tan, N.T., Hong Kong  
..........................................................................................  
Type of Equipment:  
Model No.:  
Home Smart Center  
..........................................................................................  
Caution: Users should not attempt to make such connections themselves,  
but should contact the appropriate electric inspection authority, or electri-  
cian, as appropriate.  
AM-002  
..........................................................................................  
Serial No.:  
Not Labelled  
..........................................................................................  
‘’The Ringer Equivalence Number is an indication of the maximum  
number of terminals allowed to be connected to a telephone inter-  
face. The termination on an interface may consist of any combination  
of devices subject only to the requirement that the sum of the Ringer  
Equivalence Numbers of all the devices does not exceed five.’’  
Year of Manufacture:  
2005  
..........................................................................................  
I, the undersigned, hereby declare that the equipment specified above conforms to the above  
Directive (s) and Standard(s).  
Place: Hong Kong  
................................................  
Joe Ng  
Project Manager  
Date:  
21st July 2005  
................................................  
55–  
2–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
g) Should you experience trouble with this equipment, please contact  
Skylink Customer Support at 1-800-304-1187 for repair or warranty  
information. If the equipment is causing harm to the telephone network,  
the telephone company may request that you disconnect the equipment  
until the problem is resolved.  
CONTENT  
Introduction..........................................................................................................................4  
Overview........................................................................................................................4  
Installation...........................................................................................................................7  
Installing the Console.................................................................................................7  
Programming Passwords..........................................................................................9  
Phone Number Programming..................................................................................10  
Contact ID Phone number.......................................................................................12  
Phone Number Programming (Calling to Central Monitoring Station)................12  
Account Number Programming..................................................................................13  
Deactivating the Digital Dialer.................................................................................14  
Installing Door/Window Sensors................................................................................15  
Installing Motion Sensor..........................................................................................16  
Operation..........................................................................................................................18  
Alert mode...................................................................................................................18  
Mute....................................................................................................................................19  
System Status..............................................................................................................20  
Arming The System.....................................................................................................20  
Disarming the system...............................................................................................21  
Disarming a triggered control panel.....................................................................22  
Disarming under Duress..........................................................................................22  
Panic...................................................................................................................................23  
System Failure............................................................................................................23  
Phone Line Failure............................................................................................23  
Sensor Failure.....................................................................................................24  
Low Battery...........................................................................................................24  
Coummunication.............................................................................................................26  
Receiving an emergency call..................................................................................26  
Remote Operation by Telephone...........................................................................27  
To access the control panel away from home......................................................27  
Advanced Programming.................................................................................................29  
Zone Dependent Setting – Beep /Alarm..............................................................29  
Zone Dependent Setting Auto Mute....................................................................32  
Zone Dependent Setting Alert Zone (Bypass zone).........................................33  
Learn Keychain / Keypad Remotes........................................................................35  
Erase Keychain / Keypad Remotes........................................................................36  
Learn Sensors..............................................................................................................37  
Sensor Location Selection Guide.............................................................................37  
Erase Sensors...........................................................................................................39  
HomeAutomation.............................................................................................................40  
Learn Control Modules............................................................................................40  
Erase Control Modules............................................................................................43  
Event Trigger..............................................................................................................45  
Trouble Shooting..............................................................................................................47  
Accessories......................................................................................................................49  
System Configuration.....................................................................................................53  
FCC Information................................................................................................................53  
h) Please follow instructions for repairing if any (e.g. battery replacement  
section); otherwise do not alternate or repair any parts of device except  
specified.  
i) Connection to party line service is subject to state tariffs. Contact the  
state public utility commission, public service commission or corporation  
commission for information.  
j) NOTICE: If your home has specially wired alarm equipment connected to  
the telephone line, ensure the installation of this modelAM-002 does not  
disable your alarm equipment. If you have questions about what will  
disable alarm equipment, consult your telephone company or a quali-  
fied installer.  
NOTICE: According to telephone company reports, AC electrical surges,  
typically resulting from lightning strikes, are very destructive to telephone  
equipment connected toAC power sources. To minimize damage from  
these types of surges, a surge arrestor is recommended.  
CE........................................................................................................................................55  
54–  
3–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Information  
INTRODUCTION  
Consumer Information:  
Overview  
a) This equipment complies with Part 68 of the FCC rules and the require-  
ments adopted by the ACTA. On the bottom of this equipment is a label  
that contains, among other information, a product identifier in the format  
US:AAAEQ##TXXXX. If requested, this number must be provided to the  
telephone company.  
Congratulations on your purchase of a Home Smart Center. This is a security  
control panel which not only functions as a security system, but also monitors  
your premises by giving you alert notification when the system is not armed. It  
is also a home automation center, which allows you to remotely control house-  
hold appliances and lights, even when you are away from home. It can be  
controlled by dialing in from any touch tone phone, which makes it even more  
convenient and powerful. Additional accessories such as different kinds of  
sensors and controllers can be added to suit your specific needs.  
b) An applicable certification jacks Universal Service Order Codes (USOC)  
for the equipment is provided (i.e., RJ11C) in the packaging with each  
piece of approved terminal equipment.  
This user instructions will guide you through the whole setup procedure as well  
as all the programming instructions. Please follow the instructions closely, you  
should find it very easy to set up the system.  
c) A plug and jack used to connect this equipment to the premises wiring  
and telephone network must comply with the applicable FCC Part 68  
rules and requirements adopted by theACTA.Acompliant telephone  
cord and modular plug is provided with this product. It is designed to be  
connected to a compatible modular jack that is also compliant. See  
installation instructions for details.  
Alert  
Automation  
When Home (System Not Armed)  
Beep Beep  
Alarm  
d) The REN is used to determine the number of devices that may be con-  
nected to a telephone line. Excessive RENs on a telephone line may  
result in the devices not ringing in response to an incoming call. In most  
but not all areas, the sum of RENs should not exceed five (5.0). To be  
certain of the number of devices that may be connected to a line, as  
determined by the total RENs, contact the local telephone company. [For  
products approved after July 23, 2001, the REN for this product is part of  
the product identifier that has the format US:AAAEQ##TXXXX. The digits  
represented by ## are the REN without a decimal point (e.g., 03 is a  
REN of 0.3). For earlier products, the REN is separately shown on the label.]  
Not Home (System Armed)  
Communicator  
Zone 1  
Sensor 1  
Triggered  
Alarm  
In the package, you should find the following items:  
One Control Panel  
ML-001A  
e) If this equipmentAM-002 causes harm to the telephone network, the  
telephone company will notify you in advance that temporary discontinu-  
ance of service may be required. But if advance notice isn’t practical, the  
telephone company will notify the customer as soon as possible. Also,  
you will be advised of your right to file a complaint with the FCC if you  
believe it is necessary.  
One Motion Sensor (For ML-100A Only)  
Two Door / Window Sensors (For ML-100A Only)  
PS-101  
f) The telephone company may make changes in its facilities, equipment,  
operations or procedures that could affect the operation of the equipment.  
If this happens the telephone company will provide advance notice in  
order for you to make necessary modifications to maintain uninterrupted  
service.  
WD-101  
One Keychain Remote (For ML-100A Only)  
4B-101  
4–  
53–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM CONFIGURATION  
INTRODUCTION  
Master Password  
____________________  
One AC adapter  
Secondary Password ____________________  
Duress Password  
____________________  
One telephone cord  
Sensor locations and settings  
Batteries for all sensors (For ML-100A Only)  
- 1 PC 9V Alkaline Battery (PS-101)  
- 1 PC 12V Alkaline Battery Type 23A  
(4B-101 -installed)  
- 2 PCS 3V Lithium Battery CR-2032  
(WD-101 -installed)  
ZONE  
SENSOR 1  
SENSOR 2  
BEEP / ALARM AUTO MUTE  
Beep / Alarm Y / N  
EVENT TRIGGER ALERT  
Example  
Front Door  
Front Window  
Disabled / On / Off  
Y / N  
1
2
3
4
5
Rechargeable battery of the Control Panel:  
North American version  
Phone number settings  
PHONE MEMORY  
PHONE NUMBER  
321-123-4567  
REDIAL COUNT  
REPEAT COUNT  
Example  
5
5
1
2
3
4
5
European Version  
Mounting hardware  
Ball-head joint  
(For ML-100A Only)  
Keychain / Keypad Remotes settings  
Mounting Plate  
(For ML-100A Only)  
KEYCHAIN / KEYPAD LOCATIONS  
OWNER (KEYCHAIN) / LOCATION (KEYPAD)  
Example  
Keychain Owner - John  
6
7
8
9
0
Screws  
Pack  
Basic installation involves the following procedures:  
Control Modules settings  
1. Install Control Panel ML-001A  
2. Program Passwords  
CONTROL MODULES  
LOCATIONS / APPLIANCES  
Example  
Family room lighting  
6
7
8
9
0
3. Program Phone Numbers  
4. Install Door / Window Sensors WD-101 (For ML-100A Only)  
52–  
5. Install Motion Sensor PS-101 (For ML5-100A Only)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
INTRODUCTION  
7
8
11  
1
Control Module SW-100  
(US and Canada)  
- To turn home appliances / lights on / off  
]
- Max rating: 960W (Resistive)  
2
Control Module SW-101U (UK), SW-101F  
(French), SW-101G (German)  
(3 models for 3 countries)  
- To turn home appliances / lights on / off  
3
4
5
6
10  
9
17  
18  
Emergency Dialer (AD-433S)  
- External dialer with user programmable voice  
message  
905-608-9223  
- Calls up to 9 phone numbers  
®
AD-433  
- One personal voice recording up to 40 seconds  
- Can be installed anywhere within 100 feet from  
the control panel, with a phone socket  
13  
12  
Swing door opener (DM-100)  
- Remotely open / close a swing door  
- Fits most interior doors  
16  
14  
15  
1. Zone LEDs  
2. Numeric Keypad  
3. Arm button  
11. Built-in Siren and Speaker  
12. Programming button  
13. Buzzer Mode Selector  
4. Status button  
5. Mute button  
6. Panic button  
7. Power LED  
8. Arm LED  
14. Phone Jack for external phone  
15. Line Jack for telephone line  
16. Adapter socket  
17. Battery Compartment  
18. Language Selector (only available for  
models support multiple languages)  
9. Program LED  
10. System Low Battery LED  
6–  
51–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
INSTALLATION  
Installing the Console  
Audio Sensor (AS-101)  
It is important determine where the control panel will be located. Please follow  
the criteria below to select the ideal location for the control panel.  
- When audio level exceeds preset limit, it will trigger the  
alarm  
- Place beside smoke detector, CO detector, so when these  
-
-
-
Place it where electrical outlet and phone line can be accessed  
Place it where it is easily accessible by the users  
Place it away from any doors or windows which could be accessed by  
non-intended users  
detectors are triggered, the control panel will be triggered  
-
Place is away from extreme temperature sources such as oven, stove  
and away from large metal objects which could affect the wireless  
performance  
Remote Control (4B-101)  
- Additional keychain remotes for other family members  
- To arm, disarm or trigger the panic alarm with this remote  
After a location has been selected, you may begin the installation and connect all  
the necessary wires and power up the unit.  
Keypad Control (KP-434)  
- External keypad control  
- To arm, disarm or trigger the the panic alarm with this  
remote  
1. Undo the 2 screws on the battery cover.  
- Ideal mounting locations include upper floor, backdoor, or  
garage  
Wrist Watch Style Panic Remote (HW-101)  
- Activate the panic alarm instantly with this remote  
- Wear it as a watch  
2. For models support multiple languages,  
Language  
select the desired language based on  
selector  
- Splashproof design, can be worn during showering  
the setting below:  
1. German  
2. Spanish  
3. French  
4. English  
Panic Transmitter (PT-101)  
- Activate the panic alarm instantly with this remote  
- Wear it as a pendant  
- Splashproof design, can be worn during showering  
3. Connect the power adapter to the  
socket inside the battery compart-  
ment. The power adapter should  
be connected to an AC electrical  
outlet. You should see all LEDs  
turn on, LO BATT LED should be  
off.  
®
Audio Alarm (AA-433)  
- External Siren  
- Powered by AC adapter with backup battery  
50–  
7–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
INSTALLATION  
4. Insert the rechargeable battery to the battery compartment. There are 2  
different types of rechargeable battery for 2 markets:  
Additional sensors and transmitters as well as add on accessories are available  
to work with your system.  
a. North American Version: Lead Acid  
Connect the 2 wires to the battery. Red wire  
connects to the “+” terminal on the battery.  
Black wire connects to the “-” terminal on the  
battery. Markings on the battery should face up.  
Door/Window Sensor (WD-101)  
- Magnetic Contact Sensor  
- For all doors or windows  
- Batteries included  
b. European Version: Ni-MH  
Plug in the wire from the battery to the battery  
socket inside the battery compartment.  
Repeater (RP-434)  
- Extend the operation range between 2 wireless devices,  
such as any sensors and control panel  
- Doubles the operation range automatically between  
sensors and control panel  
5. After inserting the rechargeable battery, the LO  
BATT LED will be off if the battery is fully  
charged, otherwise it will be on.  
6. Connect the phone line from the wall socket to  
the “LINE” socket inside the battery  
compartment.  
Water Sensor (FS-101)  
7. [OPTIONAL] If another telephone that will be  
using the same telephone jack, you may  
- Alerts you when water is detected  
- Ideal for water detection in basement, under the sink, even  
bathroom  
connect this telephone to “PHONE” outlet of the  
control panel by a phone cord (not provided).  
(Optional)  
8. The phone line(s), cord of the power adapter  
should all come out from the lower right corner  
of the control panel in order to close the battery  
cover properly.  
Garage Door MonitorTM Sensor (GS-101)  
(Available in US and Canada)  
- Monitors your garage door  
- Alerts you when the garage door is left open  
9. The battery cover can now be closed, and tighten  
the 2 screws to secure the battery cover.  
PWR, ARM, PROG LEDs should be flashing,  
zone LEDs should be off.  
Garage Door MonitorTM Sensor (GS-102)  
(Available outside US and Canada)  
- Monitors your garage door  
10. The control panel is intended to be mounted on a  
flat wall. 2 screws are required to mount the  
control panel securely on the wall. It should not be  
mounted too high or too low. In most situations, just  
below eye level is ideal.  
- Alerts you when the garage door is left open  
7-1/8"  
11. Once you have selected the mounting  
location, tighten 2 screws on the wall.  
They should be  
Indoor/Outdoor Motion Sensor (PS-101)  
- Monitors area in a 110 degree ARC and up to 40 feet away  
from the sensor  
7-1/8" apart from each other, on the same  
horizontal level. Do not tighten the screws  
all the way in, leave about 1/8" from the  
wall in order for the control panel to be  
hanged onto the wall.  
TM  
8–  
49–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE SHOOTING  
INSTALLATION  
Programming Passwords  
Sensors  
Master Password can be used for programming, arming, disarming the  
system, and telephone access. The default Master Password is [1234].  
When a sensor is triggered, the  
control panel doesn’t respond at all,  
what is the problem?  
- Make sure the battery in the sensor is  
installed properly, pay attention to the  
polarity.  
- Make sure the sensor is learned to the  
control panel. Follow instructions on  
page 37 on how to learn a sensor.  
- You may try to bring the sensor closer to  
the control panel, ensure it is not out of  
the operation range.  
Secondary Password can be used for arming, disarming the system, and  
telephone access. Secondary Password cannot be used for programming.  
The default Secondary Password is [0000].  
Duress Password is used when you are forcibly compelled to disarm the  
control panel. Entering the duress password will stop the siren from sounding  
but the control panel will silently call the emergency phone numbers for help.  
The default Duress Password is [3838]. You should definitely change this  
password and let all the users know this password.  
My motion sensor sometimes gets  
triggered by itself, how can I prevent  
that?  
Ensure the motion sensor is not facing  
direct sunlight, nor any A/C or furnace  
vents. You may also reduce the sensitivity  
to low. If your motion sensor is located  
outdoors, you may want to relocate it.  
After mounting the door sensor, it  
doesn’t work anymore.  
- Please ensure the magnet is aligned with  
the red marking on the transmitter.  
Changing Passwords  
- If you are mounting the sensor on to a  
metal door or window, a spacer may be  
required to avoid magnetic interference  
caused by the metal door / window.  
- Make sure the sensor is within the operation  
range of the control panel by bringing it  
closer to the control panel.  
It is strongly recommended to change all 3 passwords when you first set  
up the system.  
In order to change the password, follow the procedures below.  
Step  
Keys  
Function  
Description  
Note  
[PROG]  
Enter master  
password to  
programming mode  
3 beeps for valid  
password. 1 long  
beep for invalid  
password.  
My motion sensor is not very  
responsive, sometimes when I walk  
by it, the control panel doesn’t respond,  
but sometimes it does.  
The motion sensor is designed to detect the  
“First Motion”. First Motion means no motion  
is detected within the past 20 seconds,  
and if a motion is then detected, that is the  
“First Motion”. So if you continue to walk  
in front of the motion sensor, it will only  
pick up the first motion. Unless you wait  
for 20 seconds, then walk again, the control  
panel will respond. Otherwise, the control  
will only respond to the first motion.  
Enter  
Programming  
mode  
1
[MPIN]  
[2]  
Select  
password  
programming  
2
3
[1] - Master password  
[2] - Secondary password  
[3] - Duress password  
[1] or  
[2] or  
[3]  
Select which  
password to  
change  
[new  
4-digit  
password]  
Select any 4-digit pass-  
word, each digit can be  
from 0 to 9  
Enter new  
password  
4
5
[new  
4-digit  
password]  
Enter new  
password to  
confirm  
Enter the new password 3 beeps if new pass-  
again for confirmation  
word is accepted. You  
will hear [Password  
Accepted]  
48–  
9–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
TROUBLE SHOOTING  
Phone Number Programming  
Control Panel  
You can program up to 6 Emergency Phone Numbers. When the system is in panic,  
the control panel will call these phone numbers and announce its status.  
Questions  
Solutions  
Why I can’t arm my system?  
Make sure none of the sensors are  
triggered. You can check this by the zone  
LEDs, none of them should blink.  
The 6 emergency phone numbers include:  
- 5 voice message phone numbers  
- 1 Contact ID message phone number  
I cannot arm the system even when no  
sensor is triggered, and the ARM LED  
is off.  
You need to disarm the system again by  
either entering the password or disarm by  
keychain remote. Although the ARM LED  
is off, but the system is not completely  
disarmed after an alarm was triggered.  
Refer to page 22 on how to completely  
disarm a control panel after an alarm has  
been triggered.  
Program the following for Voice Message Phone Numbers  
- Phone memory (from 1 to 5), this is where the phone numbers will be stored  
- Phone number, up to 29 digits.  
- Redial count, this is how many times that phone number will be called, from 1  
to 9 times.  
- Repeat count, this is how many times the emergency message will be repeated,  
from 1 to 9 times.  
Step  
Keys  
Function  
Description  
Note  
Why the ARM LED keeps flashing?  
That means you have not programmed any  
emergency phone numbers. For instructions  
on how to program emergency phone  
numbers, please see page 10.  
Enter  
Programming  
mode  
Enter master password to  
programming mode  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
1
[PROG]  
[MPIN]  
Select phone  
number  
programming  
You will hear [Enter  
phone memory].  
2
3
[1]  
How do I exit programming mode  
when I’m in the middle of it?  
You can press the programming button on  
the side of the unit to quit programming  
anytime.  
During emergency, phone  
memory 1 will be called first,  
then phone memory 2, 3, 4, and  
5. So phone memory 1 has  
higher priority.  
Enter phone  
memory  
[1] to [5]  
When a sensor is triggered, the alarm  
sounds instantly even it is not armed,  
why is that?  
You have programmed that sensor in alarm  
mode, instead of beep mode. Please refer  
to page 29 for instructions of how to program  
it back to beep mode.  
Phone number can be up to 29  
digits.**  
You will hear [Enter  
Redial].  
[Phone  
Enter phone  
number] number  
+ [Arm]  
4
5
When the alarm is triggered, why  
the control panel won’t call all the  
programmed phone numbers? It  
always stops before calling the  
last number.  
The control panel will stop calling when it  
is disarmed by any one of the recipients.  
Disarm can also be done locally thru the  
keypad on the control panel by entering a  
valid password.  
You will hear [Enter  
Repeat].  
Redial is the number of times  
that phone number will be  
called. Each phone number  
can have a different redial  
count, from 1 to 9 times.  
Enter Redial  
[1] to [9]  
+ [Arm]  
count  
Why the control panel doesn’t beep  
when a sensor is triggered, while  
only the zone LED flashes?  
You have placed the buzzer mode selector  
on the side of the control panel to “II”, this  
will disable the beeping. Placing it to “I” will  
enable the beeping.  
Repeat is the number of times  
that voice emergency message  
will be played, from 1 to 9 times.  
It is recommended to set up  
the repeat time to 5 or more.  
You will hear [Phone  
Accepted] indicating the  
phone number and its  
settings have been  
Enter Repeat  
count  
6
[1] to [9]  
+ [Arm]  
The control panel is in armed mode,  
why activating a sensor will not cause  
an alarm, or call any emergency phone  
number?  
If the triggered sensor is programmed in the  
Alert Zone (Bypass Zone), alarm will not  
sound, and emergency call will not be made  
if this sensor is triggered. The control panel  
will only respond when it is disarmed, in  
alert mode.  
programmed successfully.  
**Note:  
You may enter a 3-second pause between digits by pressing [Mute] if needed.  
You may also enter consecutive multiple pause periods. For example, you may  
enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number  
(123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be  
a password to a paging system, or an access code for a phone dialing system.  
47–  
10–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOME AUTOMATION  
INSTALLATION  
Note:  
- It’s not recommended to program 911, fire station or any emergency services  
phone numbers into any of the phone memories without their approvals.  
- Ensure to program a valid phone number and write down the programmed  
phone number on the System Setting Information provide on the back of this  
user's instructions.  
®
This row  
Buttons to Disable Event Tigger  
:
Zone LED : Off  
- You may quit programming by pressing [PROG] button at any time.  
- If no phone number is programmed, the ARM LED will continue to flash.  
Press once will enable “Event Trigger On”,  
press again will enable “Event Trigger Off”.  
This row of buttons operates in toggle manner,  
between event trigger on and event trigger off.  
Testing Phone Numbers:  
This row  
:
Buttons to Enable Event Trigger  
After you have programmed all the phone numbers, you should verify you have  
programmed the phone numbers correctly. This can be done by triggering the  
alarm silently by entering the duress password, so it dials to the programmed  
phone numbers without sounding the alarm.  
Zone LED : 1) On (Event Trigger On)  
2) Flash (Event Trigger Off)  
ENABLE EVENT TRIGGER  
DISABLE EVENT TRIGGER  
Button [1]  
Note:  
Zone 1  
Zone 2  
Button [6]  
Button [7]  
Button [8]  
Button [9]  
Button [0]  
You must inform the recipients of the programmed phone numbers, so they know  
what to expect when they receive the phone call from the control panel during an  
emergency. These recipients should know the password to your control panel if  
you expect them to have remote access of your control panel. For more informa-  
tion regarding receiving the emergency call, please refer to page 26.  
Button [2]  
Button [3]  
Zone 3  
Zone 4  
Zone 5  
Button [4]  
Button [5]  
1. Press [Arm], you should hear beeping from the control panel.  
2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number.  
3. The called party should receive the call. Pick up the call and say “Hello”, an  
emergency message “System Panic” will be played. If the programmed phone  
doesn’t ring, ensure the phone number is programmed correctly, or reprogram  
this phone number again.  
4. After the emergency message has been played for several times (depending on  
how many times it was programmed), the called party will hear “Enter Password”.  
5. Enter either the master password or secondary password. If the correct  
password is accepted, you will hear “Password Accepted”, otherwise, you will  
hear “Password Failure”.  
6. Press [0][#] on the telephone to hang up.  
7. The control panel will start to dial the next programmed phone number.  
Note:  
- Refer to page 26 [Receiving the Emergency Call] for more info on how to react  
to an emergency call.  
- The password is treated as a confirmation of the emergency message. Once a  
valid password is entered, the control panel will not call that number again, it  
will proceed to the next number.  
- If any one of the called parties disarms the control panel, the control panel will  
not continue to dial the remaining phone numbers.  
- After calling all the programmed phone numbers, the control panel will be back  
to the previous operation mode.  
46–  
11–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
HOME AUTOMATION  
Event Trigger  
Contact ID Phone number  
You can program a telephone number for calling to the central monitoring station.  
When the system is in panic, the control panel will call this phone number and  
will send out a Contact ID message with event code 140, which represents  
“General Alarm”.  
You can control up to 5 different devices not only manually, but also automatically. It is  
called Event Trigger. That means when a sensor is triggered, the control panel will  
transmit a signal to activate the designated control module. Applications include:  
- Lights on when you open the front door  
(walking into a room, lights on automatically),  
this is called "Event Trigger on".  
Follow the instructions below to program the necessary info in order to call a  
monitoring station:  
- Phone number of central monitoring station (up to 29 digits)  
- Account number given by the Central Monitoring Station  
- Lights off when you open a door. (walk away  
from a room, turns lights off), this is called  
"Event Triggered off".  
Event Trigger On  
Phone Number Programming (Calling to Central Monitoring Station)  
Event trigger is only applicable to the sensor(s)  
and control module in the same zone. For  
example, you can program control module 1 to  
be on or off when zone 1 sensor(s) is triggered.  
You can also program control module 2 to be  
on / off when zone 2 sensor(s) is triggered.  
Step  
1
Keys  
Function  
Description  
Note  
3 beeps for valid  
password. 1 long  
beep for invalid  
Enter Program- Enter master  
ming mode  
Press [PROG]  
Press [MPIN]  
password to  
programming mode  
password.  
Select phone  
number  
programming  
Factory Default: This feature is disabled for  
all zones at the factory.  
You will hear  
[Enter Phone  
Memory]  
Press [1]  
Press [0]  
2
3
Event Trigger Off  
To change the event trigger setting follow the instructions below.  
You will hear  
[Phone Zero]  
During emergency,  
the Contact ID phone  
number has the highest  
priority, it will be the  
first number to call.  
Enter phone  
memory  
Step  
1
Keys  
Function  
Description  
Note  
Enter master  
password to  
programming  
mode  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
Enter Program-  
ming mode  
[PROG]  
[MPIN]  
You will hear  
Phone number  
can be up to 29  
digits.  
Enter phone  
number  
Enter [Phone  
number] +  
[Arm]  
4
Select Event  
Trigger  
After [7] is entered,  
some zone LEDs will be  
off, on or flash. This  
indicates the setting of  
event trigger.  
2
[Phone Accepted]  
indicating the phone  
number has been  
programmed  
[7]  
successfully.  
Select which  
zone you would  
like to enable /  
disable event  
trigger.  
If event trigger “ON” is  
Disable Event  
Trigger: [1] to  
[5]  
Refer to the  
diagram below  
to select the  
appropriate  
setting.  
3
enabled, that zone LED will  
be on. If event trigger “OFF”  
is enabled, that zone LED  
will flash. If it is disabled, the  
zone LED will be off. You are  
allowed to make multiple  
changes before terminating  
programming mode.  
Enable Event  
Trigger: [6] to  
[0].  
Terminate  
programming  
mode.  
PROGLED  
will be off.  
[PROG]  
when  
finished.  
4
12–  
45–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOME AUTOMATION  
INSTALLATION  
Account Number Programming  
ZONE LED  
Off  
DESCRIPTION  
In order to program the account number, follow the procedures follow:  
Zone is not occupied by any control module  
Flashes twice  
That means a remote has occupied that zone.  
THIS IS NOTACONTROLMODULE,THEREFORE, SHOULD NOTBE  
ERASED.  
Step  
1
Keys  
Function  
Enter  
Programming  
mode  
Description  
Note  
Enter master  
password to  
programming  
Press [PROG]  
Press [MPIN]  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
Flashes once  
That zone is occupied by a control module. You may select this  
zone to erase this control module.  
mode  
Select  
password  
programming  
Press [2]  
Press [0]  
2
3
Flashes once,  
then twice  
That means this zone is occupied by a remote AND a control module.  
You may select this zone to erase the control module.  
Select to  
[0] = Add/change  
add / change account number  
account  
number  
** Table F: Zone LED status for erasing control module.  
Enter new  
account  
number  
Enter [New 4-  
digit Account  
Number]  
Enter the 4-digit  
account number  
given by the  
This number can be a  
combination of 0-9,  
B,C,D,E & F.  
4
Part 2 Erase communication from Control Panel to Control Module  
central monitoring  
station.  
Step  
1
Keys  
Function  
Description  
Note  
To enter 0-9:  
Enter by the keypad 0-9  
directly.  
Remove the  
control module  
from the  
To enter B,C,D,E,F:  
electrical outlet  
Press [STATUS] and the  
ARM light will stay on.  
Then press the following  
keys for the correspond-  
ing letters (1=B, 2=C, 3=D,  
4=E, 5=F).  
Control module LED  
will flash rapidly  
indicating all the  
memory is erased.  
You may now  
Press and hold  
the learn button  
on the control  
module while  
plugging in the  
control module  
to an electrical  
outlet.  
2
To erase the  
memory of the  
control module  
Press [STATUS] to return  
back to number-mode  
when you want to input  
numbers. The ARM light  
will turn off.  
release the learn  
button.  
You can toggle between  
the number or letter mode  
by pressing [STATUS]  
when entering the  
Once the memory of the control module is erased, all of its memory is cleared. If  
you have other remotes / control panels controlling this control module, you need  
to re-program those remotes / control panels.  
account number.  
Enter the new  
account num-  
ber again for  
confirmation  
3 beeps if new account  
number is accepted. You  
will hear [Password  
Accepted]  
Enter [New 4-  
digit Account  
Number]  
5
44–  
13–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
HOME AUTOMATION  
Operation  
Deactivating the Digital Dialer  
To turn off a light with the control panel:  
1. Press the device number button on the control panel, i.e. pressing 1 will turn  
off device 1, pressing 2 will turn off device 2.  
You can deactivate the digital dialer by erase the phone number memory for  
central monitoring station.  
2. You will hear [Device X Off], where X is the device number.  
3. You will also see the PROG LED flashing, indicating the control panel is  
sending out the wireless signal to control the specific device.  
4. If the receiver receives the signal, the control panel will announce [Device  
Off Accepted].  
Step  
Keys  
Function  
Description  
Note  
Enter Program- Enter master  
ming mode  
3 beeps for valid  
password. 1 long  
beep for invalid  
password.  
Press [PROG]  
Press [MPIN]  
1
password to  
programming mode  
To turn on a light with the control panel:  
Press [1]  
You will hear:  
[Enter Phone  
Memory]  
Select phone  
number  
programming  
2
1. Press the number below the device number that you would like to turn on, i.e.  
pressing 6 will turn on device 1, pressing 7 will turn on device 2.  
2. You will hear [Device X On], where X is the device number.  
3. You will also see the PROG LED flashing, indicating the control panel is  
sending out the wireless signal to control the specific device.  
4. If the receiver receives the signal, the control panel will announce [Device  
On Accepted].  
Press [0]  
Enter phone  
memory  
3
4
Press [ARM]  
You will hear  
[Phone Zero  
Empty Memory]  
indicating the phone  
number have been  
deleted, the digital  
dialer is deactivated.  
Confirm delete  
the phone  
number.  
Erase Control Modules  
To erase a control module from the control panel, it is similar to learning a  
control module, which involves 2 parts.  
Note: If no phone number is programmed to call the central monitoring station,  
the digital dialer is automatically disabled.  
1. Erase the memory of the control panel  
2. Erase the memory of the control module  
Part 1 Erase the memory of the Control Panel  
Step  
1
Keys  
Function  
Enter  
Programming password to  
Description  
Note  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
[PROG]  
[MPIN]  
Enter master  
mode  
programming mode  
Select erase  
control  
module  
After [0] is entered, some  
zone LEDs will flash or  
stay off. The zone LEDs  
represent whether that zone  
is occupied by any control  
module. **See Table F  
2
3
[0]  
programming  
To erase an  
occupied  
control module,  
press [1] to [5].  
After you have selected the  
remote location, you will  
hear 3 beeps and verbal  
confirmation [Device X  
Empty Memory], where  
X is the control module  
location you have selected.  
Refer to the table  
below to select  
the control  
Select the  
control module  
location you  
would like to  
erase  
module location.  
14–  
43–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (ML-100A Only)  
HOME AUTOMATION  
Installing Door / Window Sensors  
Control Module [1] is represented by zone LED 1  
Window / Door Sensor is used to monitor doors or windows that  
open and close. When these doors / windows are open or  
closed, the sensors will transmit a signal to the control panel  
to notify the user. These sensors consist of 2 parts, one is the  
transmitter, the other is the magnet.  
This row  
Buttons for  
Learning Control Module  
:
Transmitter  
Magnet  
Before installing the sensor, remove the battery isolator by pulling out the yellow  
tab. Once the isolator is removed, the corresponding zone LED on the control  
panel will flash and buzzer will beep. If the magnetic contact is closed, the  
beeping will stop.  
Note:  
- Both Window/Door Sensors have been programmed at the factory. They are  
Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the  
beeping and zone LED to determine which one is zone 1 and which is zone 2.  
Part 2 Learn signal from Control Panel to Control Module  
Step  
1
Keys  
Function  
Enter  
Programming  
mode  
Description  
Note  
Press and hold  
the learn button  
on the Control  
Module until its  
LED starts to  
flash.  
LED on the Control Module  
will flash indicating it is in  
learn mode.  
Mounting the Sensor  
The transmitters should be mounted on the door frame or window frame by  
double sided tape. The magnet should be mounted on the door or window by  
either double sided tape or screws. Make sure the magnet is aligned with the  
red marking on the transmitter. If the surface of the frame is flat enough, double-  
sided foam tape is sufficient, otherwise, it is recommended to screw the  
mounting plate to the frame, then apply double sided tape. After mounting the  
sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the  
AAA+ logo is in the upright position.  
After [X] is entered, you  
will hear [Device X On]  
indicating you have trans-  
mitted an ON signal for  
device X, where X is the  
Control Module Location.  
The LED on the Control  
Module should be off,  
indicating it has learned  
the signal, you may now  
release the learn button  
and the LED will stay on  
again.  
[6] to [0]  
Transmit an ON Refer to the  
signal for the chart below to  
2
selected device determine which  
from the Control button [6] to [0]  
Panel to the  
Control Module. You should  
transmit the “ON”  
to press.  
command for the  
selected device.  
Double-sided  
foam tape  
Magnet on the right  
Mounting plate  
and screws  
(optional)  
Sensor  
Magnet on the left  
CONTROL MODULE  
LOCATION  
TRANSMIT  
BUTTON [X]  
Testing:  
1
2
3
4
5
6
7
8
9
0
After mounting the sensor, test the sensor by opening and closing the door or  
window. Open the door or window will result in the followng:  
1. Beeping - The number of beep represents the zone number.  
2. Zone LED flashing - Number of flash represents the sensor number.  
42–  
15–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION (ML-100A Only)  
HOME AUTOMATION  
Part 1 Learn signal from Control Module to Control Panel  
2 Single flash  
Step  
1
Keys  
Function  
Description  
Note  
[PROG]  
[MPIN]  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
Enter Program- Enter master  
ming mode  
password to  
programming  
mode  
1. Beep___Beep___  
Beep___Beep___  
............  
[4]  
Select learn  
control module  
programming  
After [4] is entered, some  
zone LEDs will flash or  
stay off. The zone LEDs  
represent whether that  
zone is already occupied  
by another control  
2
Note:  
- Try to mount the sensors as far away from the floor as possible to avoid  
damaging them. Mounting the sensors at a higher position will also result in  
better operating range.  
module.**See Table E.  
[1] to [5]  
Select the  
location [1], [2],  
[3], [4], or [5].  
Select control  
module location  
(Max. 5 control  
modules)  
After you have selected  
the control module location,  
that zone LED will be on.  
3
- Do not mount the sensor to the exterior of the door / window, always mount the  
sensor to the interior side of the door / window to avoid being damaged or  
stolen by non-intended users.  
Once the signal  
is transmitted to  
the Control Panel,  
that signal will be  
stored.  
You will hear  
Activate the  
control module  
by pressing its  
learn button  
Send signal  
from control  
module to  
4
[Device X Accepted],  
where “X” is the control  
module location.  
Installing Motion Sensor  
The motion sensor is most suitable for guarding a large area such as living room,  
family room, or bedroom. It can also be used to monitor a hallway or stairway.  
control panel.  
once quickly.  
Insert Battery  
ZONE LED  
DESCRIPTION  
Undo the screw on the back of the motion sensor and  
remove the battery cover. Connect a 9V alkaline battery  
to the battery connector. Please note the polarity.  
Off  
Zone is not occupied by any control module  
Flashes once  
This zone is occupied by another control module. Programming  
another remote to this zone will overwrite the previous control  
module.  
If you are planning to install the motion sensor outdoor,  
you should reduce the sensitivity by placing the jumper  
at location “2”.  
For indoor application, if you want to reduce the  
sensitivity, you can change the jumper setting to  
“2” as well.  
Flashes twice  
This zone is occupied by a remote. You can still program a control  
module to this zone, and it will not overwrite the remote you have  
in this zone.  
Sensitivity  
Flashes once,  
then twice  
This zone is occupied by a remote AND a controlmodule. If you  
program another control module to this zone, it will overwrite the  
previous control module, but not the remote.  
Jumper Location 1 High Sensitivity  
Jumper Location 2 Low Sensitivity  
Caution:  
** Table E: Zone LED status for learning control module.  
Depending on the environment, if you experience a false trigger when the motion  
sensor is placed outdoors, you should relocate it or even place it indoors. Wind  
blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the  
location at where the motion sensor is mounted could cause a false trigger, you  
should change the mounting location for such sensor.  
16–  
41–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOME AUTOMATION  
INSTALLATION (ML-100A Only)  
The Control Panel can be used to control lights and home applicances with a  
Control Module, (Control Module is sold separately). Garage door opener can be  
controlled with a Garage Door Receiver (sold separately). The Control Panel can  
control up to 5 Control Modules / Garage Door Receivers.  
For outdoor monitoring, please refer to page 33 to program the motion sensor  
to Alert Zone.  
You may now close the battery cover and  
re-insert the screw.  
Mount the ball-head joint on the wall with  
screws provided. Slide the back of the  
sensor into the ball-head joint. The  
mounting angle can be adjusted.  
There are 3 ways to control these modules / receivers:  
1. Using the keypad on the control panel to  
operate these modules / receivers manually  
Testing  
Walk test should be performed after the motion sensor is  
mounted. Walk in the detected area, if motion is detected, a  
red light inside the sensor will glow. If the red light does not  
glow, motion has not been detected and you may need to  
re-position the sensor. Ensure you walk test all the locations  
that you would like the motion sensor to cover.  
2. Calling in away from home using a touch tone  
phone (Refer to “Remote Operation by Telephone”)  
Door open  
Lights  
on  
3. Setting up Event Trigger  
Note:  
DETECTING AREA: (Unit = meter)  
(Refer to Advanced Programming)  
1.2M  
- Perform the walk test after you have inserted the  
battery for more than 1 minute.  
14  
55°  
55°  
11°  
12  
10  
8
- Before performing the walk test, the sensor should  
not detect any motion.  
- After motion is detected once, the sensor will not  
be triggered unless no motion is detected for 20  
seconds. Therefore, wait for at least 20 seconds  
during walk testing between 2 activations.  
6
27°  
22°  
22°  
4
2
M
These control modules should be programmed to the control panel as device  
1 to 5. Please follow the programming instructions below to program these  
control modules.  
12°  
SENSOR  
0
1
2
3
4
5
6
7
8
9
10 11 12 13  
Learn Control Modules  
Caution:  
When installing the motion sensor, avoid placing it near heat or cold producing  
devices (i.e. A/C or furnace vents, fans, ovens, space heaters, etc). Air movement,  
especially caused by changes in temperature may trigger the Motion Sensor and  
cause false alarms. Please carefully test your Motion Sensor so that it will only be  
triggered by wanted movement.  
Both control panel and control module are transceivers, meaning they can transmit  
and receive signals from each other. For home automation, the user will initiate an  
action from the control panel, such as sending a signal to turn on the light, then the  
control module will receive such signal and respond. The control module will then  
send back a confirmation to the control panel  
to indicate the light has been turned on.  
(command  
Turn on  
You have now successfully installed and programmed the Control Panel and its  
sensors. Please follow the rest of the instructions for operations and advanced  
programming.  
signal)  
Therefore, during programming,  
Control  
Module  
it is required to program 2 things:  
®
1
2
3
4
5
PWR  
ARM  
1
2
3
4
5
1. Signal from control module to  
control panel (confirmation signal)  
6
7
8
9
0
PROG  
BATT  
ARM  
STAT  
US  
LO  
MUTE  
Control  
Panel  
2. Signal from control panel to  
control module (command signal)  
Confirm on  
(confirmation  
signal)  
40–  
17–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCED PROGRAMMING  
OPERATION  
The Control Panel is always in one of the 2 operating modes:  
1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.  
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.  
This row  
Buttons for  
Sensor 1  
:
SENSOR 1 SENSOR 2  
Button [1] Button [6]  
Zone 1  
Zone 2 Button [2] Button [7]  
Zone LED :  
Flash once  
Alert Mode  
Button [8]  
Button [9]  
Button [0]  
Button [3]  
Button [4]  
Button [5]  
Zone 3  
Zone 4  
Zone 5  
The Control Panel will be in alert mode automatically if the system is not armed.  
Alert mode allows users inside the premises to know what sensor is triggered.  
It is intended to be used when someone stays inside the premises.  
This row  
Buttons for  
Sensor 2  
:
In alert mode, the control panel will give you notification of the triggered sensor(s)  
by voice announcement, unique beeping and LED flashing.  
Zone LED :  
Flash twice  
1
2
Number of beeps  
Zone of the triggered sensor  
Number of flashes of zone LED Sensor number of the triggered sensor  
Erase Sensors  
Note:  
- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors  
can be programmed to the control panel. Please refer to page 37, "Sensor  
Location Selection Guide" for detail information.  
Proceed to the following to erase a sensor.  
Step  
1
Keys  
Function  
Enter  
Programming password to  
Description  
Note  
Enter master  
[PROG]  
[MPIN]  
3 beeps for valid password.  
1 long beep for invalid  
programming mode  
password.  
Alert Mode Examples (Door/Window sensor sold separately)  
mode  
Zone 1 Sensor 1  
1.  
2. Single flash  
Beep___Beep___  
Beep___Beep .....  
2
3
Select erase  
remote  
programming  
[9]  
After [9] is entered, some  
zone LEDs will flash or  
stay off. The zone LEDs  
represent whether that zone  
is occupied by any sensor.  
**See Table D below.  
Select the  
Refer to the table  
To erase an  
occupied  
sensor, press  
[1] to [0].  
After you have selected the  
sensor, you will hear 3 beeps  
and verbal confirmation  
[Zone X Sensor Y Empty  
Memory], where X and Y  
are the zone and sensor  
numbers you have selected.  
sensor you below to select the  
would like to remote location.  
erase  
Zone 3 Sensor 2 window  
open  
2. Double flash  
1.  
Beep Beep Beep___  
Beep Beep Beep___  
ZONE LED  
Off  
DESCRIPTION  
Zone is not occupied by any sensor  
This zone is occupied by sensor 1.  
This zone is occupied by sensor 2.  
Note:  
-For Door / Window sensor, alert notification (beeping and LED flashing) will  
continue until the sensor is in closed position, i.e. closing the window or door.  
Flashes once  
Flashes twice  
-For motion sensor, the alert notification was disabled at the factory default. To  
perform the walk test, it requires to enable the Alert Zone (Bypass Zone) feature  
in the Control Panel. After the walk test, it needs to disable this alert zone feature  
otherwise it will bypass the signal in the alarm mode. Please refer to the page 33,  
"Alert Zone" for detail. Please refer to information.  
Flashes once,  
then twice  
This zone is occupied by sensors 1 and 2.  
** Table D: Zone LED status for erasing sensors.  
18–  
39–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
ADVANCED PROGRAMMING  
ZONE DEPENDENT FEATURES  
SENSOR 1  
Location  
SENSOR 2  
Location  
Mute  
Beep / Alarm  
Beep / Alarm  
Auto Mute  
Y / N  
Event Trigger  
Alert  
Y / N  
zone 1  
zone 2  
zone 3  
zone 4  
zone 5  
Disabled / On / Off  
When the alert beeping becomes undesired, you can terminate the beeping in 3  
different ways:  
Beep / Alarm  
Beep / Alarm  
Beep / Alarm  
Beep / Alarm  
Y / N  
Y / N  
Y / N  
Y / N  
Disabled / On / Off  
Disabled / On / Off  
Disabled / On / Off  
Disabled / On / Off  
Y / N  
Y / N  
Y / N  
Y / N  
1. Mute button - Manual mute by pressing the  
mute button  
Table C  
4. Once you have filled out the table, it should look something like this.  
Pressing the mute button will temporary  
disable the beeping for all the activated  
sensors. For example, if a window with a  
window sensor will be open for a long period  
of time, the continuous beeping may become  
undesired. Pressing the mute button will  
temporary disable the beeping for this  
ZONE DEPENDENT FEATURES  
SENSOR 1  
Location  
zone 1 Front Door  
SENSOR 2  
Location  
Front Window  
Beep / Alarm  
Beep / Alarm  
Auto Mute  
Y / N  
Event Trigger  
Disabled / On / Off  
Disabled / On / Off  
Disabled / On / Off  
Disabled / On / Off  
Disabled / On / Off  
Alert  
Y / N  
Kitchen Motion  
Back Door  
zone 2  
zone 3  
Beep / Alarm  
Beep / Alarm  
Beep / Alarm  
Beep / Alarm  
Y / N  
Y / N  
Y / N  
Y / N  
Y / N  
Y / N  
Y / N  
Y / N  
zone 4 Backyard Motion  
Basement Water Basement Motion  
zone 5  
Mute Button  
sensor only, it will still beep if other sensors  
You may refer to each column representing the zone dependent feature, to program  
each zone with the selected feature. For example, Auto Mute feature is only enabled  
for zone 3, when you are in the auto mute programming, you should enable this  
feature for zone 3 only, the rest of the zones should have this feature disabled.  
Repeat this step for all 4 zone dependent features during programming.  
are triggered. This sensor will beep again  
if this window is closed, and then opened.  
Buzzer Mode Selector  
2. Change the buzzer mode - Disable Beeping  
5. You may now follow the procedure below "Learn Sensor Continue" to program  
the sensor(s) to the desired zone(s).  
The beeping can be disabled for all  
zones by changing the buzzer mode  
selector.  
Learn Sensors - Continue  
Step  
Keys  
Function  
Description  
Enter master  
password to  
Note  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
- If the buzzer mode selector is at "I", beeping is enabled.  
- If the buzzer mode selector is at "II", beeping is disabled.  
Enter Program-  
ming mode  
[PROG]  
[MPIN]  
1
programming mode  
After [3] is entered, some  
zone LEDs will flash  
Select learn  
sensor  
programming  
[3]  
2
If beeping is disabled, all sensor alert beeping will be disabled, however, the  
voice announcement and LED flashing will still function.  
once, or twice, some will  
be off. The zone LEDs  
represent whether that  
zone is already occupied  
by another sensor.  
3. Enable Auto-Mute in Advanced Programming  
If this feature is enabled for that zone, beeping will be terminated automatically  
after 15 seconds . Refer to "Advanced Programming" - Auto Mute" on page 32  
for more information on how to enable this feature.  
**See Table D next page.  
After you have  
selected the zone, that  
zone LED will be on.  
[0] to [9]  
Select sensor  
location  
Refer to the diagram  
below to select the  
sensor location, which  
includes the zone and  
sensor number.  
3
4
Trigger sensor  
You will hear [Zone X  
Sensor Y Accepted],  
where X and Y are the  
zone and sensor numbers  
you have selected.  
Activate the  
sensor you  
would like to  
program to  
this zone.  
Once the sensor is  
activated, the signal  
will be transmitted  
to the Control Panel  
which will be stored.  
38–  
19–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
ADVANCED PROGRAMMING  
Learn Sensors  
System Status  
The control panel continuously monitors the system status as well as all the  
sensors status. It will monitor occurrences such as triggered sensors, low  
battery sensors, malfunction sensors, or phone line failure etc.  
You can program up to 10 sensors to the control panel. There are 5 zones on  
the control panel, each zone can program up to 2 sensors. Before program-  
ming a sensor, you must decide which sensor location (zone number and  
sensor number) you would like to program the sensor to. It is strongly recom-  
mended that you refer to “Sensor Location Selection Guide” before deciding  
which sensor location you would like to program the new sensors to. Some  
features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3)  
alert zone , 4) event trigger. Explanation for each feature can be found in the  
following pages in Advanced Programming:  
In order to check the system status, user can press the “Status” button on the  
control panel, voice announcement will be made regarding the system and  
sensor status. When the “Status” button is pressed, you will be notified if any of  
the following events is occurring:  
- System armed or disarmed  
- Any triggered sensors  
- Any sensors with low battery warning  
- Any sensors with failure warning  
- Phone line failure  
1. Beep/Alarm Setting - Page 29  
2. Auto Mute - Page 32  
3. Alert Zone - Page 33  
4. Event Trigger - Page 45  
Refer to page 23 for more details regarding system failures.  
Sensor Location Selection Guide  
You can program up to 10 sensors to the control panel. There are 5 zones and  
maximum 2 sesnors per zone. The 4 features mentioned above are Zone  
dependent features meaning both sensors in that zone will operate based on  
the setting for that zone. So if you program 2 sensors into one zone, those 2  
sensors will react in the same manner for those zone dependent features. For  
example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1,  
and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a  
zone dependent feature for sensor 1 only, but not sensor 2.  
Arming the System  
You should arm the system when you are the last person to leave the house. By  
arming the system, the control panel will call the preprogrammed emergency  
phone numbers and the siren will sound when break-in occurs.  
Caution: Only arm the system when nobody is expected to be inside the premises.  
When someone is expected to be within the premises, the system should not be  
armed.  
Therefore, the followings are some suggestions of how you should select the  
sensor location.  
To arm the system, follow the procedures below:  
1. Check all the zone dependent features, and determine if you would like to  
enable any one of them.  
Exit delay 45 seconds  
BeepBeep  
45 seconds later  
ARM LED on.  
System  
Armed  
OR  
2. If you decide not to enable any zone dependent features and keep the  
factory default setting, you can simply program the sensor to any sensor  
location based on your own preference. Omit the following steps and  
proceed to "Learn Sensor - Continue".  
1. Press [Arm] on the control 2. Leave the premises 3. After 45 seconds.  
panel or keychain remote. within 45 seconds.  
System will be armed.  
3. If you decide to enable some of the zone dependent features, check Table C  
below. Circle the zone dependent feature selections. If there are features  
that you would like to enable for more than 2 sensors, you need to select  
more than one zone for those features.  
1. Press [Arm] button on the control panel when no sensors are triggered.  
You can also use the keychain remote to arm the system by pressing arm  
button on the remote.  
20–  
37–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCED PROGRAMMING  
OPERATION  
Remote [6] is represented by zone LED 1  
Note:  
- The control panel cannot be armed if there are triggered sensors. Make sure  
all sensors are in closed position, i.e. (close all doors, windows, no movement  
should be detected etc).  
- The control panel can be armed if there are sensors with low battery or failure  
warning.  
®
REMOTE LOCATION  
6
ZONE LED  
1
2
3
4
5
7
8
9
0
2. After pressing the “ARM” button, the “ARM” LED will flash and you will have 45  
seconds to leave the premises, this is called the exit delay. You will hear  
beeping during the exit delay interval. The beeping rate will change from slow  
to fast, the faster the beep rate, the less time you have left to leave the premises  
before the siren sounds.  
Erase Keychain / Keypad Remotes  
3. When the exit delay expires, the control panel will announce “System Armed”,  
beeping will stop and the ARM LED will be on steadily. This indicates the  
system is now armed.  
Follow the instructions below to erase keychain or keypad remotes / receivers.  
Step  
1
Keys  
Function  
Description  
Note  
[PROG]  
[MPIN]  
Enter master  
password to pro-  
gramming mode  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
Enter  
Programming  
mode  
Note:  
The control panel can also be armed remotely when nobody is home, with a touch  
tone phone. Please refer to “Remote Operation by Telephone” on page 27.  
2
Select erase  
remote  
After [0] is entered, some  
zone LEDs will flash or stay  
off. The zone LEDs  
represent whether that zone  
is occupied by any remote.  
** See Table B below.  
[0]  
programming  
Disarming the system  
If a sensor is triggered while the control panel is armed, such as entering a house  
with an armed control panel, an entry delay will be triggered. User is allowed to  
disarm the control panel during the 30-second entry delay. If the control panel is  
not disarmed within 30 seconds, siren will sound immediately and emergency  
calls will be made. To disarm the control panel, follow the instructions below.  
After you have selected the  
remote location, you will hear 3  
beeps and verbal confirmation  
[Device X Empty Memory],  
where X is the remote location  
you have selected.  
Select a remote  
location [6], [7],  
[8], [9] or [0].  
Select remote  
location you  
would like to  
erase  
To erase  
3
an occupied  
remote, press  
[6] to [0].  
Entry delay 30 seconds  
BeepBeep  
Arm LED off  
System  
Arm LED flashes  
BeepBeep  
ZONE LED  
Off  
DESCRIPTION  
Zone is not occupied by any remote  
OR  
Disarmed  
Flashes twice  
This zone is occupied by a remote. You may select this zone to  
erase this remote.  
Flashes once  
This zone is occupied by a control module (Optional).  
THIS IS NOTAREMOTE CONTROL, THEREFORE, SHOULD NOTBE  
ERASED. (Refer to page 43 Erase Control Module for more  
information)  
3. Once the system is  
disarmed, the Arm  
LED will be off.  
1.Entering the premises  
will trigger the entry  
delay.  
2.Enter password within  
30 seconds or press the  
disarm button on the  
keychain remote.  
Flashes once,  
then twice  
This zone is occupied by a remote AND a control module.  
You may select this zone to erase the remote.  
1. During the entry delay, the system will beep for 30 seconds, the ARM LED will  
flash during this entry delay interval. The faster the beep, the less time you  
have left to disarm the control panel before the siren sounds.  
** Table B: Zone LED status for erasing keychain/keypad remote(s).  
* Please refer to erase control module on page 43.  
36–  
21–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCED PROGRAMMING  
OPERATION  
2. You must enter a valid password, either the Master Password, or Secondary  
Password to disarm the system before entry delay expires.  
Learn Keychain / Keypad Remotes  
Additional keychain or keypad remotes can be programmed to the control panel.  
Maximum of 5 keychain/keypad remotes can be programmed to the control panel.  
3. When a valid password is entered, you will hear “System Disarmed” and the  
entry delay beeping will stop, the ARM LED will be off.  
- Keychain or keypad remotes should be programmed to Device 6 to Device 0.  
Note:  
- The control panel can also be disarmed remotely when nobody is home, with a  
touch tone phone. Please refer to “Remote Operation by Telephone” on page 27.  
Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8,  
9, or 0, which is the bottom row of the numeric keypad of the control panel.  
Step  
1
Keys  
Function  
Description  
Note  
- If 3 consecutive incorrect passwords are entered, alarm will sound immediately,  
the control panel will be in panic mode, and start calling the emergency phone  
numbers.  
3 beeps for valid  
password. 1 long beep  
for invalid password.  
Enter master  
password to  
programming mode  
Enter Program-  
ming mode  
[PROG]  
[MPIN]  
Select learn  
remote  
programming  
After [4] is entered, some  
zone LEDs will flash or  
stay off. The zone LEDs  
represent whether that  
zone is already occupied  
by another remote.  
[4]  
2
Disarming a triggered control panel  
If "System Panic" is announced from the control panel after it has been disarmed,  
that means the alarm was triggered when it was in armed mode. Follow the  
procedures below to set the control panel back to standby mode.  
** See Table A below.  
Select remote Select a remote  
location  
location [6], [7],  
(Max. 5 remotes) [8], [9] or [0].  
After you have selected  
the remote location, that  
zone LED will be on.  
[6] to [0]  
1. If the alarm was caused by sensor(s), there will be flashing LEDs and  
beeping indicating which sensor(s) triggered the alarm. You may want to  
check the condition of the triggered sensor(s), the sensor(s) may be damaged  
if there were break-ins.  
2. You need to reset the sensor manually by triggering it twice, i.e. open and  
then close a door / window sensor, or walk in front of the motion sensor. The  
LED representing that sensor will stop flashing after it receives the signal  
from the sensor.  
3
4
Trigger remote  
Once the signal is  
transmitted to the  
Control Panel, that  
signal which will  
be stored.  
Activate the  
remote by  
pressing any  
one of the  
buttons.  
You will hear  
[Device X Accepted],  
where “X” is the remote  
location.  
3. You must now enter the password again on the control panel or press the  
disarm button on the keychain remote, as an acknowledgement of the alarm  
event. This will set the control panel back to standby mode.  
ZONE LED  
Off  
DESCRIPTION  
Zone is not occupied by any remote  
Flashes twice  
This zone is occupied by another remote. Programming another  
remote to this zone will overwrite the previous remote.  
Disarming under Duress  
Flashes once  
This zone is occupied by a control module* (Optional).  
You can still program a remote to this zone, and it will not overwrite  
the control module* you have in this zone. (Refer to page 40 Home  
Automation for more information)  
If you are forcibly compelled to disarm the control panel, you may enter the Duress  
Password. Entering the duress password will terminate the entry delay, i.e. no  
more entry delay beeping. But the control panel will silently call the emergency  
phone numbers for help. The called party will hear the voice announcement  
“System Panic”.  
Flashes once,  
then twice  
This zone is occupied by a remote AND a control module*.  
If you program another remote to this zone, it will overwrite the  
previous remote, but not the control module*.  
Note:  
- The default duress password is [3838].  
** Table A: Zone LED status for learning keychain/keypad remote(s).  
* Please refer to learn control module on page 40.  
22–  
35–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCED PROGRAMMING  
OPERATION  
Panic  
To enable alert zone feature, follow the instructions below.  
Pressing the panic button on the control  
panel or keychain remote will cause the  
siren to sound and outgoing calls will  
be made to the preprogrammed phone  
numbers, “System Panic” will also be  
announced. This can be used in any  
emergency situation.  
Step  
Keys  
Function  
Description  
Note  
OR  
[PROG]  
[MPIN]  
Enter Program- Enter master  
ming mode  
1
3 beeps for valid  
password. 1 long beep  
for invalid password.  
password to  
programming mode  
After [8] is entered,  
some zone LEDs will  
flash or stay on. This  
indicates whether alert  
zone is selected.  
Select Alert  
Zone.  
[8]  
2
3
To stop the siren and disarm the system, user can enter a valid password, or  
press the disarm button on the keychain remote. This will terminate the siren  
and the control panel from calling the rest of the emergency phone numbers.  
Disable  
Alert Zone: zone you  
[1] to [5]  
Select which  
Refer to the  
diagram below to that zone LED will be on.  
select the  
appropriate  
setting.  
If alert zone is selected,  
would like to  
select as Alert  
Zone.  
If it is not selected, the  
LED will flash. You are  
allow to make multiple  
changes before terminat-  
ing programming mode.  
Enable  
Alert Zone:  
[6] to [0].  
ARM  
DISARM  
PANIC  
AUX  
Terminate  
programming  
mode.  
[PROG]  
when  
finished.  
PROG LED will be  
off.  
4
- Control other Skylink receiver  
such as Garage Door Receiver  
System Failure  
Control Panel constantly monitors itself and its sensors. If there are any trouble  
conditions, the control panel will advise the user. These trouble conditions include:  
®
DISABLE  
ALERT ZONE ALERT ZONE  
ENABLE  
This row  
Buttons to  
Disable Alert Zone  
:
Button [6]  
Button [7]  
Button [8]  
Button [9]  
Button [0]  
Zone 1 Button [1]  
- Phone Line Failure  
Zone 2  
Button [2]  
Zone LED : Flash  
- Sensor Failure (loss of supervisory signal)  
- Low Battery – Control Panel  
- Low Battery – Sensors  
Zone 3 Button [3]  
Zone 4  
Button [4]  
This row  
Buttons to  
:
Zone 5  
Button [5]  
Enable Alert Zone  
Phone Line Failure  
Zone LED : ON  
When the phone line is disconnected or malfunctions, the control panel will  
instantly notify the user by:  
1. Both Power [PWR] and Program [PROG] LEDs will flash together;  
2. Voice announcement “Phone Line Failure” will be played.  
When phone line failure occurs, please check the phone line connection, ensure  
the phone line is plugged into both the control panel and the wall socket securely.  
You should also check the phone line with a normal telephone to determine if it  
can dial out to a phone number. If it cannot dial out, that indicates the phone line  
is not in service, you should contact your local phone company.  
34–  
23–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
ADVANCED PROGRAMMING  
Sensor Failure  
The control panel constantly monitors its sensors, if the control panel fails to  
communicate with any sensors, it will notify the user by:  
ENABLE  
AUTO MUTE  
DISABLE  
AUTO MUTE  
This row  
:
Buttons to  
Disable Auto Mute  
Zone 1  
Zone 2  
Button [6]  
Button [1]  
1. The zone LED of the failed sensor will be on steadily;  
2. Voice announcement “zone X sensor Y failure” will be played.  
Zone LED : Flash  
Button [2] Button [7]  
Zone 3  
Zone 4  
Zone 5  
Button [8]  
Button [9]  
Button [0]  
Button [3]  
Button [4]  
Button [5]  
When sensor failure occurs, try the following:  
This row  
Buttons to  
Enable Auto Mute  
:
1. Check if the sensor is located at where it should be, and whether there is any  
physical damage to the sensor.  
Zone LED : ON  
2. If the failed sensor is not physically damaged, try to activate the sensor and see  
if the control panel reacts to such activation.  
3. If not, try to remove the sensor from its location, and bring it closer to control  
panel and activate the sensor. It is possible that the sensor is installed too far  
from the control panel and it cannot establish a steady communication with the  
control panel. If this is the case, please install the sensor closer to the control  
panel.  
Alert Zone (Bypass Zone)  
As explained earlier, the control panel can operate in 2 different modes, 1) Alert  
Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control  
panel will either give a 30 seconds entry delay, or siren will sound immediately  
(with instant alarm). However, there are sensors that you do not want to trigger  
the alarm when the system is armed. Such as an outdoor sensor, or any other  
sensors that you only want to give you alert notification. Under such circum-  
stances, zone(s) can be programed to react only when the control panel is in  
alert mode, these zones will be automatically bypassed when the control panel  
is in alarm mode. These zones can also be considered as "Bypass zones".  
Low Battery  
Control Panel  
The control panel is powered mainly by the adapter. However, during power outage,  
it will be powered by the rechargeable backup battery. Under standby conditions,  
these batteries can last for 48 hours.  
It is recommend to enable alert zone if:  
When the backup battery is running low, the “LO BATT” LED on the control panel  
will be on, indicating the backup battery should be recharged. To recharge the  
backup battery, plug in the power adapter. It takes approx. 20 hours to fully charge  
the backup battery.  
- You do not consider the sensors in that zone an emergency  
- Sensors in that zone are located outdoors  
- When nobody is at home, you do not want to know the status of the sensor(s) in  
that zone  
Sensors (For ML-100A Only)  
Factory Default: This feature was disabled for all zones at the factory.  
All of the sensors are battery powered. Depending on the operating condition  
and environment, the battery life varies from 9 months to 2 years. 9V alkaline  
battery is used for the motion sensor, the battery life is approximately 9 months.  
Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of  
approximately 2 years. For other sensors, please refer to the user’s instructions  
regarding the battery life.  
24–  
33–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
ADVANCED PROGRAMMING  
When the sensor is running low in battery, the sensor will send a wireless low  
battery signal to the control panel. The zone LED representing that sensor will be  
on steadily, indicating sensor(s) in that zone is in trouble condition. Control Panel  
will also have an announcement to advise the user the trouble condition is low  
battery, such as “zone X sensor Y low battery”, where X and Y represent the zone  
and sensor number. Please replace the battery of that sensor.  
Auto Mute  
When a sensor is triggered in alert mode, audio warning will be emitted, either  
beep or alarm. For example, if a door is opened, the beep will not stop until the  
door is closed. If the door is open for 2 hours, the beep will go on for 2 hours.  
There are times that this is not desired. With the auto mute feature enabled, the  
beep will go on for only 20 seconds. After that, even if the sensor remains open,  
the beep will stop only the zone LED will flash to indicate the sensor is triggered.  
Beep will go on again if the sensor is closed and opened again.  
Keychain Remote (For ML-100A Only)  
The battery of the keychain remote (Alkaline, Type 23A, 12V) needs to be replaced  
when either one of the followings occurs:  
Note: Auto Mute only functions when the control panel is in alert mode (disarmed).  
If the control panel is in alarm mode (armed), a triggered sensor will result in  
entry delay or instant alarm.  
1. The LED on the keychain doesn’t flash or on when a key is pressed; or  
2. The operating range starts to decrease.  
Factory Default: This feature was disabled for all zones at the factory.  
To replace the battery:  
To enable auto mute feature, follow the instructions below.  
1. Undo the two screws on the back of the transmitter.  
The bottom case will then come off.  
2. Using a small screwdriver or pen, pry out the old  
battery from one end.  
Step  
Keys  
Function  
Description  
Note  
[PROG]  
[MPIN]  
Enter Program-  
ming mode  
Enter master  
password to  
3 beeps for valid  
password. 1 long beep  
1
3. Place the new battery in position. A diagram in the  
battery compartment indicates which end is positive  
and which is negative.  
programming mode for invalid password.  
Select Auto Mute  
Enable / Disable  
After [6] is entered, some  
zone LEDs will flash or  
stay on. This indicates  
whether Auto Mute is  
enabled or disabled.  
[6]  
2
3
4. Close the battery cover and reinsert two screws.  
-
If auto mute is enabled,  
that zone LED will be on.  
If it is disabled, the LED  
will flash. You are allow  
to make multiple changes  
before terminating  
Disable  
Select which  
Refer to the diagram  
Auto Mute: zone you would below to select the  
+
[1] to [5]  
like to enable /  
disable auto mute.  
appropriate setting.  
Enable  
Auto Mute:  
[6] to [0].  
programming mode.  
Terminate  
programming  
mode.  
PROG LED will be off, and  
you will hear 3 beeps.  
[PROG]  
when  
finished.  
4
32–  
25–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMUNICATION  
ADVANCED PROGRAMMING  
Receiving the Emergency Call  
Follow the procedures below to program the beep / alarm setting.  
If you are on the list as one of the recipients of the emergency call, you should read  
the following instructions carefully. You should also notify all the persons you will  
be calling so they know how to react when they receive the emergency call.  
Step  
1
Keys  
Function  
Description  
Enter master  
password to  
Note  
[PROG]  
[MPIN]  
EnterProgramming  
mode  
3 beeps for valid password.  
1 long beep for invalid  
programming mode password.  
The control panel will call you when there are emergencies such as break-ins,  
smoke, fire events, or someone at home needs assistance.  
Select Beep /  
Alarm Setting  
After [5] is entered, some zone  
2
3
[5]  
LEDs will flash or stay on.  
This indicates whether that  
zone is set to beep or alarm.  
1. When the phone rings at the calling location, the person who answers the  
phone will hear a message related to the emergency events, such as  
“System Panic”, or “Zone 1 Sensor 1 Triggered” etc. This message may be  
repeated several times depending on how it was programmed.  
Select which  
Refer to the  
zone you would diagram below to  
Set to Beep:  
[1] to [5]  
If Alarm is set for that zone,  
that zone LED will be on. If  
Beep is set, the LED will  
flash. You are allowed to  
make multiple changes before  
terminating programming  
mode.  
like to Beep or  
Alarm.  
select the appro-  
priate setting.  
Set toAlarm:  
[6] to [0].  
2. After the message has been repeated for  
a certain number of times, the control panel  
will ask for a valid password, you will hear  
“Enter Password”.  
PROG LED will be off, and  
you will hear 3 beeps.  
Terminate pro-  
gramming mode.  
[PROG] when  
finished.  
4
Zone 1  
Sensor 1  
®
Triggered  
BEEP  
ALARM  
3. Enter the 4-digit password to have access  
This row  
:
Button [1] Button [6]  
Zone 1  
to the control panel. If a valid password is  
accepted, you will hear “Password Accepted”,  
otherwise, you will hear “Password Failure”.  
Buttons for Beep  
Zone 2 Button [2] Button [7]  
Zone LED : Flash  
Button [8]  
Button [9]  
Button [0]  
Button [3]  
Button [4]  
Button [5]  
Zone 3  
Zone 4  
Zone 5  
Enter  
Password  
This row  
:
Buttons for Alarm  
4. After entering the correct password, you  
can follow the “Phone Command” instruc-  
tions to perform the required tasks, such  
Zone LED : ON  
as disarm, turn on / off devices or check the  
-Arm  
system status etc. For further information  
-Disarm  
-Check status  
of how to control the system remotely,  
-Control lighting etc.  
Example:  
please refer to the next section, "Remote  
-Disconnect  
If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply  
Operation by Telephone".  
press [0] at step 3.  
This will change the zone 5 setting to “Alarm”.  
26–  
31–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ADVANCED PROGRAMMING  
COMMUNICATION  
Remote Operation by Telephone  
System Armed (Alarm Mode)  
If a zone is set to “Beep”, the control panel will give entry / exit delay.  
If a zone is set to “Alarm”, the siren will sound immediately without entry delay  
The control panel can be operated while you are away from home. You can  
have access to the control panel with any touch tone phone to perform a variety  
of operations, listed below.  
- Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with  
the alarm setting on, the siren will sound immediately without entry delay, it is  
called “Instant Alarm”. The siren will not stop until the siren timeout or a valid  
password is entered. Control panel will call the emergency phone numbers to  
notify the users of the alarm situation.  
- Arm  
- Disarm  
- Lights, Home Applicances on / off (Requires additonal Control Module)  
- Garage door open / close (Requires additional Garage Door Receiver)  
- System status  
- Disconnect  
When a sensor is triggered, there are 4 options:  
ZONE SETTING  
There are 2 ways you can have access to the remote phone operation:  
OPERATING MODE  
Disarmed (Alert)  
Armed (Alarm)  
BEEP  
ALARM  
1. You can call the control panel when you are away from home; or  
2. When the control panel calls you during emergency.  
1) Beep  
2) Alarm sounds immediately  
3) Entry / Exit Delay  
4) Alarm sounds and calls  
preprogrammed phone  
numbers immediately  
To access the control panel away from home  
Calling in when you are away from home  
Factory Default: All zones were programmed to Beep at the factory.  
You may consider to programming the zone(s) into Alarm mode if:  
1. Call your home phone number, or the number that the phone line of the control  
panel is connected to.  
2. Hang up after the second ring.  
- You need immediate attention if that sensor is triggered, such as flood sensor,  
smoke sensor etc.  
- The sensor will not be triggered on a daily basis, such as a door that you  
normally will not open, and if it opens, you would like to know immediately.  
3. Wait at least 10 seconds, but not more than 40 seconds, then call the phone  
number again.  
4. The control panel will pick up the phone call and request for a valid user  
password, you will hear “Enter Password”. You can enter either the Master  
Password or Secondary Password. If the password is correct, you will hear  
“Password Accepted”, otherwise, you will hear “Password Failure”.  
Caution:  
It is not recommended to program an outdoor sensor to Alarm mode, which may cause  
false alarm. For outdoor sensors, they should be programmed into an Alert Zone,  
please refer to page 33 for details.  
5. Once the password is accepted, you can have access to all the operations  
listed below.  
30–  
27–  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMMUNICATION  
ADVANCED PROGRAMMING  
Advanced Programming allows users to customize the control panel to react  
differently under different conditions. Features such as:  
Table 1: Remote Phone Operations  
SYSTEM OPERATION  
PHONE COMMAND  
DESCRIPTION  
- When a sensor is triggered, the control panel can beep or alarm  
- Beeping can be terminated automatically after a fixed period of time for some sensors  
- Some sensors can be programmed to beep only, never alarm  
- When a door is open, turn lights on  
Turn on device x  
[x] = 1 to 5  
x+[*]  
Turn devices on will hear [Device X On]. When the  
control module receives the on signal, it will turn on the  
plugged in device, and send a confirmation back to the  
control panel. You will then hear [Device On Accepted].  
- Program additional sensors and remotes  
x+[#]  
Turn off device x  
x = [1 to 5]  
Turn devices off will hear [Device X Off]. When the  
control module receives the off signal, it will turn off the  
plugged in device, and send a confirmation back to the  
control panel. You will then hear [Device Off Accepted].  
Programming Summary  
COMMAND  
[PROG] + [1]  
[PROG] + [2]  
[PROG] + [3]  
[PROG] + [4]  
[PROG] + [5]  
[PROG] + [6]  
[PROG] + [7]  
[PROG] + [8]  
[PROG] + [9]  
[PROG] + [0]  
DESCRIPTION  
Program Phone Numbers  
Program Password  
Check system status  
Arm  
You will hear system status announcement  
You will hear [System Armed]  
You will hear [System Disarmed]  
Phone line disconnect  
[8]+[#]  
[7]+[#]  
Learn Sensors  
[9]+[#]  
[0]+[#]  
Disarm  
Learn Keychain or Keypad Transmitters / Control Modules  
Beep / Alarm Setting  
Disconnect  
Auto Mute Setting  
Event Trigger Setting  
Alert Zone (Bypass) Setting  
Erase Sensors  
Erase Keychain or Keypad Transmitters / Control Modules  
Follow the instructions below to have access to Advanced Programming.  
Beep / Alarm  
User can customize the audio warning so that when a sensor is triggered, the  
control panel may beep or alarm may sound instantly. Depending on whether the  
control panel is armed or disarmed, the audio warning is different.  
System Disarmed (Alert Mode)  
If a zone is set to “Beep”, the control panel will beep when a sensor is triggered,  
until the sensor is deactivated. Motion Sensor activation will not cause any  
beeping unless the zone for the motion sensor is programmed as a "Bypass  
Zone" (see page 33).  
If a zone is set to “Alarm”, alarm will sound instantly when a sensor is triggered.  
Alarm will stop when the sensor is deactivated, or reaches a 3-minute time out period.  
28–  
29–  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Mountfield Lawn Mower MP84401 05 User Manual
Mr Coffee Coffee Grinder BM Series User Manual
NEC Computer Monitor XV17+ User Manual
NETGEAR Network Router EX6120 User Manual
Nortel Networks Cordless Telephone 4075 User Manual
Oki Printer C9000 Series User Manual
Oregon Scientific Radar Detector WR606 User Manual
OWI Portable Speaker LGS470 User Manual
Panasonic CRT Television CT 2707D CT 3207D User Manual
Panasonic Smoke Alarm 3378 User Manual