SEQUENCE OF OPERATION
IMPINGER II ADVANTAGE
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
1130-000-A
1131-000-A
1132-000-A
1133-000-A
208VAC
240VAC
208VAC
240VAC
60 HZ.
60 HZ.
60 HZ.
60 HZ.
1 PHASE
1 PHASE
3 PHASE
3 PHASE
POWER SUPPLY
Electrical power to be supplied to the oven by a three conductor service for single
phase and a four conductor service for three phase.
Black conductor is hot.
Red conductor is hot.
Orange conductor is hot (used for three phase only).
Green conductor is ground.
CONTROL BOX AUTO
COOL DOWN
When the temperature in the control box reaches 120°F ± 3° (48.9°C ± 1.7°), the
cooling fan thermostat will switch power to the control box cooling fan. The
thermostat will interrupt power to the cooling fan when the control box
temperature falls to 100°F ± 3° (37.8°C ± 1.7°).
MAIN FAN CIRCUIT
Power is permanently supplied through the 10 amp fuses, through the normally
closed control box hi-limit thermostat, to the normally open main power switch.
Power is also supplied to the normally open cooling fan thermostat. Closing the
main power switch supplies 208/240VAC to the main fan motor, the cooling fan
motor, the primary of the control transformer, the conveyor motor and to the oven
control.
TEMPERATURE CONTROL
Closing the main power switch supplies 208/240VAC to the primary of the control
transformer. Secondary voltage, 24VAC, is supplied to the oven control. The oven
control is set to desired temperature. The thermocouple will provide varying
millivolts to the oven control. The oven control supplies 208/240VAC to the coil of
the heater relay at intermittent intervals to maintain the desired temperature. The
display on the oven control will indicate when the heater relay is energized.
NOTE: The display also indicates oven temperature.
CONVEYOR DRIVE
Closing the main power switch supplies 208/240VAC to the conveyor motor and
to the primary of the control transformer. Secondary voltage, 24VAC, is supplied
to the oven control. Setting the oven control to the desired time outputs voltage,
through a reversing switch, to the conveyor motor.
NOTE: The conveyor system uses a hall effect sensor and magnet to prove
operation of the conveyor motor. If the conveyor motor is not running, “BELT
JAM” is indicated on the display.
Impinger II – Advantage Digital Service Manual - Domestic
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SCHEMATIC DIAGRAM
MODEL 1116-000-A, 1117-000-A
SERIAL NUMBER 2038616 AND ABOVE
4
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
SCHEMATIC DIAGRAM
MODEL 1130-000-A, 1131-000-A
SERIAL NUMBER 2038616 AND ABOVE
Impinger II – Advantage Digital Service Manual - Domestic
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SCHEMATIC DIAGRAM
MODEL 1132-000-A, 1133-000-A
SERIAL NUMBER 2038616 AND ABOVE
6
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
GAS OVENS
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
MODEL 1116-000-A
MODEL 1117-000-A
NAT. GAS
LP GAS
120VAC
120VAC
60 HZ.
60 HZ.
SYMPTOM
POSSIBLE CAUSE
EVALUATION
Oven fan will not run
Incoming power supply
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Fuse, 10 Amp
Fuse holder
Check, replace if necessary.
Check, replace if necessary.
Hi-limit thermostat,
control box
Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Check continuity between switch terminals.
Replace switch as needed.
Check for 120VAC at motor. If no voltage is
present, trace wiring back to main power switch.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn fan blade to check for locked rotor.
Check for shorts or grounds.
Switch, main power
Main fan motor
Capacitor
WARNING: Capacitor has a stored charge,
discharge before testing.
No control box cooling
Incoming power
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Switch, main power
Cooling fan
Check continuity between switch terminals.
Replace switch as needed.
Check for 120VAC at cooling fan. If no voltage is
present, trace wiring back to power switch. If
voltage is present, and motor does not run, check
for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Check the cooling fan thermostat. (Thermostat
closes at 120°F and opens at 100°F). With the
cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace cooling fan
thermostat.
No automatic control box
cooling
Incoming power supply
Cooling fan thermostat
Cooling fan
Check for 120VAC at cooling fan. If no voltage is
present, trace wiring back to cooling fan
thermostat. If voltage is present, and motor does
not run, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check for adequate gas supply to oven.
Check to see that the manual gas shut off valve is
open. Also check flexible gas line connection for
any damage.
Oven will not heat
Gas supply
Manual gas shut off valve.
Impinger II – Advantage Digital Service Manual - Domestic
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Main fan
If not operating, refer to “Oven fan will not run”.
Centrifugal switch of main fan Check for 120VAC at wire #5 (input to centrifugal
motor
switch, located at 6-pin connector in raceway near
the main fan motor) to neutral. If no voltage is
present, trace wiring back to the main power
switch. If voltage is present, check for 120VAC at
wire #22 (output of centrifugal switch) to neutral. If
no voltage is present at #22, and the motor is
running, replace the main fan motor.
Hi-limit thermostat,
oven cavity
Terminals are normally closed. If open, reset
thermostat and retest. If thermostat will not hold
for maximum oven temperature, and oven is not
exceeding temperature setting, check for proper
location of capillary bulb in its spring holder. If the
capillary checks okay, replace the hi-limit
thermostat.
Burner blower motor
Burner transformer
Check for 120VAC supplied to burner blower
motor at wire #13 to neutral. If no voltage is
present, trace wiring back to the main power
switch. If voltage is present, and the motor is not
running, check for opens, shorts or grounds.
WITH POWER OFF: Turn motor to check for
locked rotor.
Check for 120VAC supplied to the primary of the
burner transformer. If no voltage is present, trace
wiring back to the oven cavity hi-limit thermostat.
If voltage is present, check for 24VAC at
transformer secondary. If there is primary voltage
but no secondary voltage, replace burner
transformer.
Centrifugal switch of burner
blower motor
Check for 24VAC at motor connector, wire #13 to
neutral. If voltage is not present, trace wiring back
to transformer. If voltage is present, check for
voltage at wire #14 to neutral. If no voltage is
present at wire #14, and motor is running, replace
burner blower motor.
Ignition control
Check for 24VAC at ignition control terminals
marked “24V”, if no voltage is present, trace wiring
back to centrifugal switch. Check for 120VAC to
ignition control at terminal “L1” to neutral. If no
voltage is present, trace wiring back to main
power switch. When 24VAC is supplied to the
ignition control, the ignition control switches
120VAC to the hot surface igniter If 24VAC and
120VAC are supplied to ignition control, but there
is no voltage at the hot surface igniter, replace the
ignition control.
Hot surface igniter
Ignition control
If 120VAC is present at hot surface igniter
terminals, visually check to see that the igniter is
heating (igniter may be viewed through the port in
the end of burner tube). The igniter should glow
bright red. If the igniter does not heat, replace the
hot surface igniter.
After 45 seconds of hot surface igniter pre-heat,
the ignition control will switch 23VAC to the gas
control valves. Check for 24VAC output from
ignition control across terminals marked “valve”
and “valve gnd”. If no voltage is present, replace
ignition control.
Gas control valves
When 24VAC is supplied to the gas control
8
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
valves, the valve should open. Check for gas
pressure at the manifold tap located just before
the burner. If there is no pressure, check the
incoming gas supply to be sure all manual valves
are open and flexible gas hose is properly
connected. If gas is present, and the gas control
valve is energized, but there is no gas pressure at
the burner manifold, replace the gas control
valves.
Flame will not stay lit
Hot surface igniter
Six seconds after the gas valve opens, ignition
must occur. If flame is not detected, the ignition
control will shut off and lock out. To reset the
ignition control, turn off the power switch for 45
seconds, then turn the switch on to re-try ignition.
The ignition control requires a minimum of 0.8 DC
microamps to prove flame. To check flame
sensing operation, connect a digital multimeter
(capable of measuring DC microamps) between
the “ground” terminal on ignition control and the
ground lead.
NOTE: This is a current measurement and the
meter must be connected in series
If these readings are not achieved, replace hot
surface igniter.
NOTE: The DC microamp test must be conducted
with the oven in low flame (bypass) operation. Set
the temperature control to the lowest setting.
If there is sufficient microamp current, but the
flame will not stay lit, check for proper polarity of
the 120VAC power supply.
If there is sufficient microamp current, and the
120VAC polarity is correct, but the flame will not
stay lit, replace the ignition control.
Power supply
Ignition control
NOTE: Check for proper ground connection on
ignition control.
NOTE: Flame should be on at
this time
Low flame is on,
but no main flame
Control transformer
Check for 120VAC supply to the primary of the
control transformer. If no voltage is present, trace
wiring back to the main power switch. If voltage is
present, check for 24VAC at the transformer
secondary. If there is primary voltage, but no
secondary voltage, replace the control
transformer.
Oven control
Check for 24VAC supply to control. If no voltage is
present, trace wiring back to control transformer. If
24VAC is present, check for a read-out on the
display. If there is 24VAC supplied, but there is no
read-out on the control display, replace the oven
control.
If there is a read-out on the control, set the control
to maximum temperature (see installation
operations manual for temperature adjustment).
With the control set at maximum temperature,
check for 120VAC at the temperature regulation
valve. If there is voltage at the temperature
regulation valve, proceed to “Temperature
regulation valve” for next check. If there is no
voltage at the temperature regulation valve, trace
wiring back to the oven control. If there is no
Impinger II – Advantage Digital Service Manual - Domestic
9
Download from Www.Somanuals.com. All Manuals Search And Download.
voltage output at the oven control, check the read-
out on the control. If the control reads “PROBE
FAIL”, this indicates that the thermocouple has
failed or become disconnected from the oven
control.
Thermocouple
Check to be sure that the thermocouple is
securely connected to the oven control. If the
thermocouple is connected to the oven control,
and the control indicates “PROBE FAIL”,
disconnect the thermocouple from the oven
control and measure the resistance of the
thermocouple. The thermocouple should read
approx. 11Ω. If these readings are not achieved,
replace the thermocouple. If these readings are
correct, proceed.
Oven control
If the thermocouple checks good, but the oven
control display indicates that there is a
thermocouple failure, replace the oven control. If
the oven control indicates a temperature reading
but the oven will not heat, proceed.
Thermocouple
WITH POWER ON AND THERMOCOUPLE
ATTACHED TO THE OVEN CONTROL: Measure
the DC millivolt output of the thermocouple. Refer
to the thermocouple chart (located in the
“Removal” section of the manual) for proper
millivolt readings. If these readings are not
achieved, replace thermocouple.
Oven control
If the thermocouple checks good, but there is no
120VAC output to the temperature regulation
valve, replace the oven control. If there is 120VAC
output to the temperature regulation valve,
proceed.
Temperature regulation valve Check for 120VAC supplied to temperature
regulation valve. If voltage is present, listen for
valve to open and close. Also check for opens or
shorts in the operating coil. Replace temperature
regulation valve as needed.
Intermittent heating
Thermal/overload of main fan The main fan motor and burner blower motor are
and burner blower motors
equipped with internal thermal protection and will
cease to operate if overheating occurs. As the
motors overheat and then cool, this will cause the
heating system to cycle on and off intermittently.
Improper ventilation or lack of preventive
maintenance may cause this problem. Also, most
of the problems listed under “Oven will not heat”
can cause intermittent failure.
Conveyor will not run
Power supply
Check for incoming voltage at line 1 to neutral.
There should be a reading of 120VAC. If not
present, check circuit breakers.
Fuse, 10 Amp
Fuse holder
Check, replace if necessary.
Check, replace if necessary.
Hi-limit thermostat, control box Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Check continuity between switch terminals.
Replace switch as needed.
Power switch
Control transformer
Check for 120 VAC supply to the primary of the
control transformer. If no voltage is present, trace
10
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
wiring back to the oven power relay. If voltage is
present, check for 24 VAC at the transformer
secondary. If there is primary voltage but no
secondary voltage, replace control transformer.
Check for 120 VAC supply to the conveyor motor
at wire #14 to neutral. If no voltage is present,
trace wiring back to the primary of the control
transformer. If voltage is present and the motor
will not run, check the motor windings for opens or
shorts.
Conveyor motor
WITH POWER OFF: Check the motor windings as
follows:
Grey to black - 38Ω approx.
Grey to blue - 38Ω approx.
Blue to black - 75Ω approx.
If any of the above fails, replace conveyor motor.
Check for shorts or grounds. Replace capacitor as
needed.
Capacitor, conveyor motor
WARNING: Capacitor has a stored charge,
discharge before testing.
Switch, conveyor reversing
Oven control
Check continuity between switch terminals.
Replace switch as needed.
If there is 120VAC supplied to the motor, and the
motor, capacitor, and reversing switch check
good, replace the oven control.
Conveyor motor runs, but
there is no speed display
NOTE: Display will indicate
“Belt Jam”
Oven control
Check for output voltage from oven control to hall
effect sensor (sensor is located in conveyor
motor). Measure voltage at the motor connector,
red wire and yellow wire. Voltage should be
approx. 10VDC. If no voltage is present, trace
wiring back to oven control. If there is no voltage
present at the oven control, replace the oven
control.
Conveyor motor
If there is voltage supplied to the hall effect
sensor, check for a frequency output from the hall
effect sensor. Measure frequency across the
yellow and white wires at the motor connector.
Frequency reading should be approx. 25 – 100
Hz. If these readings are not achieved, replace
conveyor motor. If the readings are achieved,
proceed.
Oven control
If the hall effect sensor readings are correct, but
there is no speed indicated on the display, replace
the oven control.
Impinger II – Advantage Digital Service Manual - Domestic
11
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
ELECTRIC OVENS
1130-000-A
1131-000-A
1132-000-A
1133-000-A
208VAC
240VAC
208VAC
240VAC
60 HZ.
60 HZ.
60 HZ.
60 HZ.
1 PHASE
1 PHASE
3 PHASE
3 PHASE
SYMPTOM
POSSIBLE CAUSE
EVALUATION
Oven fan will not run
Incoming power supply
Check circuit breakers. Reset if required. Call
power co. if needed.
Fuses, 10 Amp, motor and
controls
Check, replace if necessary.
Fuse holder
Check, replace if necessary.
Hi-limit thermostat,
control box
Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Check continuity between switch terminals.
Replace switch as needed.
Check for supply voltage at motor. If no voltage is
present, trace wiring back to main power switch.
WITH POWER OFF: Check for opens, shorts or
grounds. Turn fan blade to check for locked rotor.
Check for shorts or grounds.
Switch, main power
Main fan motor
Capacitor
WARNING: Capacitor has a stored charge,
discharge before testing.
No control box cooling
Incoming power
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Switch, main power
Cooling fan
Check continuity between switch terminals.
Replace switch as needed.
Check for supply voltage at cooling fan. If no
voltage is present, trace wiring back to power
switch. If voltage is present, and motor does not
run, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Check the cooling fan thermostat. (Thermostat
closes at 120°F and opens at 100°F). With the
cooling fan thermostat pre-heated, check for
continuity. If switch is open, replace cooling fan
thermostat.
No automatic control box
cooling
Incoming power supply
Cooling fan thermostat
Cooling fan
Check for supply voltage at cooling fan. If no
voltage is present, trace wiring back to cooling
fan thermostat. If voltage is present, and motor
does not run, check for opens, shorts or grounds.
WITH POWER OFF: Check for locked rotor.
Check for main fan operation. If it is not
operating, refer to “Oven fan will not run”.
This normally open switch should close when the
main fan is activated. Refer to the “Removal and
installation” section for proper adjustment.
Replace as needed.
Oven will not heat
Main fan motor
Air pressure switch
Hi-limit thermostat,
Terminals are normally closed. If open, reset
12
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
oven cavity
thermostat and retest. If thermostat will not hold
for maximum oven temperature, and oven is not
exceeding temperature setting, check for proper
location of capillary bulb in its spring holder. If the
capillary checks okay, replace the hi-limit
thermostat.
Control transformer
Check for 120VAC supply to the primary of the
control transformer. If no voltage is present, trace
wiring back to the main power switch. F voltage is
present, check for 24VAC at the transformer
secondary. If there is primary voltage, but no
secondary voltage, replace the control
transformer.
Oven control
Check for 24VAC supply to control. If no voltage
is present, trace wiring back to control
transformer. If 24VAC is present, check for a
read-out on the display. If there is 24VAC
supplied, but there is no read-out on the control
display, replace the oven control.
If there is a read-out on the control, set the
control to maximum temperature (see installation
operations manual for temperature adjustment).
With the control set at maximum temperature,
check for supply voltage at mercury contactor. If
there is voltage at the mercury contactor,
proceed to “mercury contactor” for next check. If
there is no voltage at the mercury contactor,
trace wiring back to the oven control. If there is
no voltage output at the oven control, check the
read-out on the control. If the control reads
“PROBE FAIL”, this indicates that the
thermocouple has failed or become disconnected
from the oven control.
Thermocouple
Check to be sure that the thermocouple is
securely connected to the oven control. If the
thermocouple is connected to the oven control,
and the control indicates “PROBE FAIL”,
disconnect the thermocouple from the oven
control and measure the resistance of the
thermocouple. The thermocouple should read
approx. 11Ω. If these readings are not achieved,
replace the thermocouple. If these readings are
correct, proceed.
Oven control
If the thermocouple checks good, but the oven
control display indicates that there is a
thermocouple failure, replace the oven control. If
the oven control indicates a temperature reading
but the oven will not heat, proceed.
Thermocouple
WITH POWER ON AND THERMOCOUPLE
ATTACHED TO THE OVEN CONTROL:
Measure the DC millivolt output of the
thermocouple. Refer to the thermocouple chart
(located in the “Removal” section of the manual)
for proper millivolt readings. If these readings are
not achieved, replace thermocouple.
Oven control
If the thermocouple checks good, but there is no
voltage output to the mercury contactor, replace
the oven control. If there is voltage output to the
mercury contactor, proceed.
Mercury contactor
Check for supply voltage to the contactor coil. If
voltage is present and the contactor will not
Impinger II – Advantage Digital Service Manual - Domestic
13
Download from Www.Somanuals.com. All Manuals Search And Download.
activate, replace the mercury contactor. Also
check each contactor for high voltage input and
output.
Heating element(s)
Check the Amp draw on each power leg for
proper load. Check the specification plate for
rating information. If the amp draw is high or low,
check the individual elements for opens, shorts
and proper resistance.
WITH POWER OFF: To check resistance of the
elements, remove all leads from the elements
and use a digital multimeter.
The element resistance is should be as follows:
208V – 27 ohms
240V – 36 ohms
Replace heating elements as needed.
The mercury contactor has probably failed in the
closed position. If there is no voltage to the
operating coil, but there is high voltage at the
contactor output, replace the mercury contactor.
The main fan motor is equipped with internal
thermal protection and will cease to operate if
overheating occurs. As the motor overheats and
then cools, this will cause the oven to cycle on
and off intermittently. Improper ventilation or lack
of preventive maintenance may cause this. Also,
most of the problems listed under “Oven will not
heat” can cause intermittent failure.
Oven heats with switch off
Intermittent heating
Mercury contactor
Thermal/overload of motor
Conveyor will not run
Power supply
Check circuit breakers, reset if required. Check
power plug to be sure it is firmly in receptacle.
Measure incoming power, call power co. if
needed.
Fuse, 10 Amp
Fuse holder
Check, replace if necessary.
Check, replace if necessary.
Hi-limit thermostat, control box Check for voltage on both sides of switch.
Terminals are normally closed. If open, reset and
test oven for proper operation. If thermostat will
not hold, and control box temperature is not
exceeding 140°F (60°C), replace thermostat.
Check continuity between switch terminals.
Replace switch as needed.
Power switch
Control transformer
Check for supply voltage to the primary of the
control transformer. If no voltage is present, trace
wiring back to the oven power relay. If voltage is
present, check for 24 VAC at the transformer
secondary. If there is primary voltage but no
secondary voltage, replace control transformer.
Check for supply voltage to the conveyor motor.
If no voltage is present, trace wiring back to the
primary of the control transformer. If voltage is
present and the motor will not run, check the
motor windings for opens or shorts.
Conveyor motor
WITH POWER OFF: Check the motor windings
as follows:
Grey to black - 240Ω approx.
Grey to tan - 240Ω approx.
Tan to black - 480Ω approx.
If any of the above fails, replace conveyor motor.
Check for shorts or grounds. Replace capacitor
as needed.
Capacitor, conveyor motor
WARNING: Capacitor has a stored charge,
14
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
discharge before testing.
Switch, conveyor reversing
Oven control
Check continuity between switch terminals.
Replace switch as needed.
If there is supply voltage to the motor, and the
motor, capacitor, and reversing switch check
good, replace the oven control.
Conveyor motor runs, but
there is no speed display
NOTE: Display will indicate
“Belt Jam”
Oven control
Check for output voltage from oven control to hall
effect sensor (sensor is located in conveyor
motor). Measure voltage at the motor connector,
red wire and yellow wire. Voltage should be
approx. 10VDC. If no voltage is present, trace
wiring back to oven control. If there is no voltage
present at the oven control, replace the oven
control.
Conveyor motor
If there is voltage supplied to the hall effect
sensor, check for a frequency output from the hall
effect sensor. Measure frequency across the
yellow and white wires at the motor connector.
Frequency reading should be approx. 25 – 100
Hz. If these readings are not achieved, replace
conveyor motor. If the readings are achieved,
proceed.
Oven control
If the hall effect sensor readings are correct, but
there is no speed indicated on the display,
replace the oven control.
Impinger II – Advantage Digital Service Manual - Domestic
15
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOVAL, INSTALLATION AND ADJUSTMENTS
IMPINGER II ADVANTAGE SERIES
CAUTION
BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER
OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY.
MAIN FAN – REPLACEMENT
A. Shut off power at main breaker.
B. Remove motor cover from back of oven.
C. Disconnect wiring and mark for reassembly.
D. Remove bolts and slide back straight out of the oven.
E. Loosen the bolt from fan hub and remove fan from motor shaft.
NOTE: Measure distance from fan blade to rear wall assembly before removal to aid in reassembly.
F. Reassemble in reverse order and check system operation.
MOTOR, MAIN FAN – REPLACEMENT
A. Shut off power at main breaker.
B. Remove motor cover from back of oven.
C. Disconnect wiring and mark for reassembly.
D. Remove bolts and slide back straight out of the oven.
E. Loosen the bolt from fan hub and remove fan from motor shaft.
NOTE: Measure distance from the fan blade to rear wall assembly before removal to aid in reassembly.
F. Remove four screws from motor support assembly.
G. Remove motor mount clamp and remove motor from oven back.
H. Remove motor mount from motor.
I. Reassemble in reverse order and check system operation.
CAPACITOR – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control box cover and front panel.
C. Discharge capacitor.
D. Remove capacitor.
E. Reassemble in reverse order and check system operation.
ON/OFF SWITCH – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control box cover and front panel.
C. Depress spring clips on sides of switch and push out.
D. Remove wires from switch and mark for reassembly.
E. Reassemble in reverse order and check system operation.
NOTE: Make sure switch housing is fully seated in control box housing.
16
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
FUSE HOLDER – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control box cover and front panel.
C. Remove wires from fuse holder and mark for reassembly.
D. Remove mounting screws or mounting nut on fuse holder and remove fuse holder.
E. Reassemble in reverse order and check system operation.
THERMOSTAT, CONTROL BOX HI-LIMIT – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control box cover and front panel.
C. Remove wires from thermostat and mark for reassembly.
D. Remove mounting screws and remove thermostat.
E. Reassemble in reverse order and check system operation.
NOTE: Push reset button on new thermostat.
COOLING FAN, CONTROL BOX – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Remove four mounting screws from fan frame.
D. Disconnect power cord and remove fan.
E. Reassemble in reverse order and check system operation.
THERMOSTAT, COOLING FAN, REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Remove wires and mark for reassembly.
D. Remove two mounting screws and remove thermostat.
E. Reassemble in reverse order and check system operation.
NOTE: Push reset button on new thermostat.
BURNER BLOWER MOTOR – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Unplug motor connector.
D. Remove three mounting screws from blower tube at burner housing.
E. Remove air shutter assembly from old motor for assembly on new motor.
F. Reassemble in reverse order and check system operation.
NOTE: Check air shutter at approximately ½ open and adjust to get a blue flame with an occasional
tip of yellow under high flame. A view port in the burner assembly should be used to observe
flame.
HI-LIMIT THERMOSTAT, OVEN CAVITY – REPLACEMENT
A. Shut off power at main breaker.
B. Remove conveyor and bottom finger assembly.
C. Remove capillary bulb from bracket in oven chamber and pull capillary tube through tube into
control box.
D. Remove all wires and mark for reassembly.
E. Remove mounting nut and remove thermostat.
F. Reassemble in reverse order and check system operation. Be sure capillary tube is securely in
the mount.
NOTE: Push reset button on new thermostat.
Impinger II – Advantage Digital Service Manual - Domestic
17
Download from Www.Somanuals.com. All Manuals Search And Download.
TRANSFORMER, BURNER – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Remove all wires from transformer and mark for reassembly.
D. Remove two mounting screws from transformer base and remove transformer.
E. Reassemble in reverse order and check system operation.
OVEN CONTROL – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control box cover and front panel.
C. Remove all wiring connections and mark for reassembly.
D. Remove oven control by pulling control from the mounting pins. Remove control from oven.
E. Before installing new oven control, set voltage jumper (located at the bottom center of the oven
control) to the proper voltage (120V/240V) position. Install the four pushbutton extensions
(included with the oven control) by pushing the extensions onto the four set buttons on control.
F. Reassemble in reverse order and check system operation.
G. Set the oven control for the proper operating mode. The 1100 series ovens use a single
temperature control system. The oven control must be set to the proper operating mode. Set
the control as follows: With the oven power switch “off”, depress the “time” and “up” buttons and
turn the oven “on”. Control will indicate ”Imp I or Imp II” Release the buttons, The control will
indicate “Temp to store”. Press the “up” or “down” button until “Imp II” appears on the display.
Press the “temp” button. The control is now set for single burner operation.
TRANSFORMER – CONTROL – REPLACEMENT
See “TRANSFORMER –BURNER - REPLACEMENT
THERMOCOUPLE – REPLACEMENT
A. Shut off power at main breaker.
B. Remove conveyor and bottom finger assembly.
C. Remove control panel top and front cover.
D. Remove thermocouple from bracket in oven chamber and pull thermocouple through tube into
control box.
E. Remove two thermocouple wires from temperature control. Note wire color and location for
reassembly
F. Reassemble in reverse order and check system operation
THERMOCOUPLE MEASUREMENT
TEMPERATURE (°F) D.C. MILLIVOLTS
200°
250°
300°
350°
400°
450°
500°
550°
600°
2.8
4.0
5.1
6.0
7.1
8.2
9.3
10.4
11.5
18
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
BURNER CONTROL – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Remove wires from control and mark for reassembly.
D. Remove mounting screws from control and remove burner control.
E. Reassemble in reverse order and check system operation.
GAS VALVE – REPLACEMENT
A. Shut off power at main breaker.
B. Shut off gas supply to the oven and disconnect the flexible gas line to oven.
C. Remove control panel top and front cover.
D. Remove the manual gas shut-off valve.
E. Remove screws from the bulkhead plate on inlet gas pipe and remove inlet gas pipe.
F. Remove pilot tube and wiring from gas valve, Mark all wiring for reassembly.
G. Disconnect pipe union in gas line and remove gas valve and piping assembly.
H. Remove piping from gas valve.
I. Reassemble in reverse order and check system operation.
J. Check all gas line fitting for leaks.
K. Adjust the gas manifold pressure on the gas valve. Refer to the specification plate on the oven
for proper rating.
TEMPERATURE REGULATION VALVE – REPLACEMENT
A. Shut off power at main breaker.
B. Shut off gas supply to the oven and disconnect the flexible gas line to oven.
C. Remove control panel top and front cover.
D. Remove bypass tube from burner manifold.
E. Remove wiring from valve and mark for reassembly.
F. Remove four mounting nuts from burner manifold and disconnect pipe union.
G. Remove temperature regulation valve and piping from oven.
HOT SURFACE IGNITER – REPLACEMENT
A. Shut off power at main breaker.
B. Shut off gas supply to the oven and disconnect the flexible gas line to oven.
C. Remove control panel top and front cover.
D. Remove temperature regulation valve. See “TEMPERATURE REGULATION VALVE”.
E. Disconnect wires from burner control.
F. Remove three mounting screws and remove burner venturi.
G. Remove mounting nut and remove hot surface igniter assembly.
H. Reassemble in reverse order and check system operation.
I. Check all gas line fittings for leaks.
Impinger II – Advantage Digital Service Manual - Domestic
19
Download from Www.Somanuals.com. All Manuals Search And Download.
BYPASS ORIFICE – REPLACEMENT
A. Shut off power at main breaker.
B. Shut off gas supply to the oven and disconnect the flexible gas line to oven.
C. Remove control panel top and front cover.
D. Disconnect bypass tube from gas valve.
E. Remove bypass orifice from gas valve.
F. Reassemble in reverse order and check system operation.
G. Check all gas line fittings for leaks.
MAIN BURNER ORIFICE – REPLACEMENT
A. Shut off power at main breaker.
B. Shut off gas supply to the oven and disconnect the flexible gas line to oven.
C. Remove control panel top and front cover.
D. Remove burner manifold. See “TEMPERATURE REGULATION VALVE”.
E. Remove main burner orifice from burner manifold.
F. Reassemble in reverse order and check system operation.
G. Check all gas line fittings for leaks.
REVERSING SWITCH – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Remove wires from reversing switch and mark for reassembly.
D. Remove mounting nut and remove switch.
E. Reassemble in reverse order and check system operation.
CONVEYOR DRIVE MOTOR – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Disconnect all wiring from motor and mark for reassembly.
D. Remove coupling from motor drive shaft.
E. Remove four screws and remove conveyor motor and mounting bracket.
F. Remove mounting bracket from conveyor motor.
G. Reassemble in reverse order and check system operation.
REVERSING CONVEYOR DIRECTION
A. Shut off power at oven switch.
B. Set conveyor reversing switch in the other position.
C. Turn oven “on” and check for proper operation.
CAPACITOR, CONVEYOR DRIVE MOTOR – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Discharge capacitor before removing wires. Mark wires for reassembly.
D. Remove mounting screw and remove capacitor.
E. Reassemble in reverse order and check system operation.
20
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
AIR PRESSURE SWITCH – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Disconnect wiring from air pressure switch and mark for reassembly.
D. Disconnect air tube from air pressure switch.
E. Remove two mounting screws and remove air pressure switch.
F. Reassemble in reverse order and check system operation. Be sure to calibrate new air pressure
switch. For proper calibration, see below.
G. Turn adjusting screw on air pressure switch fully counter clockwise.
H. Turn oven “on”.
I. Turn adjusting screw on air pressure switch clockwise until heat shuts off.
J. Turn adjusting screw on air pressure switch counter clockwise ¼ turn.
K. Reassemble control panel top and front cover.
BEARING, CONVEYOR – REPLACEMENT
A. Remove conveyor from oven and place on a flat work surface.
B. Remove connecting links from conveyor belt. See Installation Operations manual for proper
procedure. Remove conveyor belt from conveyor.
C. Move drive shaft or idler shaft toward end of conveyor, and shaft with bearing will now slip out of
conveyor frame.
D. Remove bearing from conveyor shaft.
E. Reassemble in reverse order and check system operation.
MERCURY CONTACTOR – REPLACEMENT
A. Shut off power at main breaker.
B. Remove control panel top and front cover.
C. Disconnect all wires and mark for reassembly.
D. Remove screws from mounting bracket and remove contactor.
E. Reassemble in reverse order and check system operation.
HEATING ELEMENT – REPLACEMENT
A. Shut off power at main breaker.
B. Remove back cover.
C. Disconnect heating element wires and mark for reassembly.
D. Disconnect motor wiring and mark for reassembly.
E. Remove oven back from oven.
F. Remove fan shroud.
G. Heating element may now be unbolted and removed.
H. Check new heating element for proper voltage. Reassemble in reverse order and check for
proper operation.
Impinger II – Advantage Digital Service Manual - Domestic
21
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPINGER II ADVANTAGE
GENERAL VIEW
LETTER
PART NUMBER
DESCRIPTION
A
B
C
D
E
F
G
H
I
369390
369502
Caster 4” w/mounting plate
Bottom finger cover
Columnating plate, see Installation & Operations manual
Bottom finger housing
Top finger housing
Columnating plate, see Installation & Operations manual
Top finger cover
Oven top
Conveyor hole cover (S/N 2052462 & Below)
Conveyor hole cover (S/N 2052463 & Above)
Baffle
Thumb screw
Cross support
Caster 4” w/threaded stem
Adjustable leg
Stand side
370010
369504
3695032
369511
369659
370679
369225
369211
370118
369231
369232
369019
370066
J
K
L
M
N
O
P
Plug
22
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
Impinger II – Advantage Digital Service Manual - Domestic
23
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL BOX
MODEL 1116-000-A, 1117-000-A
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
LETTER
PART NUMBER
369124
369537
370362
370378
370675
370377
7008696
369566
369524
369568
369938
369552
369366
369401
369398
369263
369556
369557
370359
369531
357067
369192
370681
369532
369507
369431
369129
369166
370376
369331
370108
370107
370355
369805
370354
370679
DESCRIPTION
Cooling fan
Power cord
A
B
C
D
Thermocouple type “K”
Conveyor Motor (S/N 2052462 & Below)
Conveyor Motor (S/N 2052463 & Above)
Motor Mount Plate (S/N 2052462 & Below)
Motor Mount Plate (S/N 2052463 & Above)
Main burner orifice, Nat.
Main burner orifice, LP
Venturi, Nat. gas
Venturi, LP gas
Hot surface igniter
Burner blower motor
Air shutter assy.
Temperature regulation valve
Gas valve, Nat./LP
E
F
G
H
J
K
L
M
N
Bypass orifice, Nat.
Bypass orifice, LP
Reversing switch
O
P
Q
R
Transformer, burner – control
Thermostat, oven cavity hi-limit
Capacitor (S/N 2052462 & Below)
Capacitor (S/N 2052463 & Above)
Ignition control
Thermostat, cooling fan
Thermostat, control box hi-limit
Fuse holder
Fuse, 10 Amp
Capacitor, conveyor motor
Finger guard
Control box top
Side panel
S
T
U
V
W
X
Y
Z
AA
BB
CC
DD
Control, oven
On/off switch
Facia
Not Shown
Drive Shaft Cover (S/N 2052463 & Above)
24
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
Impinger II – Advantage Digital Service Manual - Domestic
25
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTROL BOX
MODEL 1130-000-A, 1131-000-A, 1132-000-A, 1132-000-A
SERIAL NUMBER 2038616 AND ABOVE
(OVENS WITH PUSH BUTTON CONTROLS)
LETTER
PART NUMBER
370108
370355
369432
370354
370107
370067
369479
369025
369427
369431
369507
370383
370682
369192
357067
370359
370134
370133
353082
369129
369166
369331
370384
370676
370362
369378
7008696
370679
DESCRIPTION
Control box top
Control, oven
On/off switch
Facia, Label
Side panel
Mercury contactor, 1 phase
Mercury contactor, 3 phase
Blower air switch
A
B
C
D
E
F
G
H
I
J
Transformer, control
Thermostat, control box hi-limit
Thermostat, cooling fan
Capacitor, conveyor motor (S/N 2052462 & Below)
Capacitor, conveyor motor (S/N 2052463 & Above)
Capacitor, main fan motor
Thermostat, hi-limit, oven cavity
Reversing switch, conveyor
Cover, junction box
Junction box
Ground lug
Fuse holder
Fuse, 10A
K
Not Shown
L
M
N
O
P
Q
R
S
T
U
Finger guard
Conveyor motor (S/N 2052462 & Below)
Conveyor motor (S/N 2052463 & Above)
Thermocouple, type K
Cooling fan
Motor Mount Plate (S/N 2052463 & Above)
Drive Shaft Cover (S/N 2052463 & Above)
Not Shown
V
W
Not Shown
Not Shown
26
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
Impinger II – Advantage Digital Service Manual - Domestic
27
Download from Www.Somanuals.com. All Manuals Search And Download.
OVEN BACK ASSEMBLY
LETTER
PART NUMBER
DESCRIPTION
Fan
Fan shroud
Stand off
Heating element
208 Volt
A
B
C
D
369182
369899
369655
369183
369184
240 Volt
E
Rear wall
369976
369549
369581
Gas ovens
Electric ovens
Motor mount
Motor
F
G
369539
369181
369695
369033
369681
369979
369227
369541
Gas ovens (120VAC)
Electric ovens (208/240VAC)
Bracket, motor
Clamp, motor
Cover, back
Bracket, hi-limit
Spring
H
I
J
K
L
M
Bracket, thermocouple
28
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
Impinger II – Advantage Digital Service Manual - Domestic
29
Download from Www.Somanuals.com. All Manuals Search And Download.
CONVEYOR / DOOR
LETTER
PART NUMBER
DESCRIPTION
A
B
C
D
369611
369664
369269
370116
370671
369223
369224
369666
369226
369516
369514
369515
370509
369978
369238
370678
369513
369510
370016
369501
1123D
369927
369925
369926
369929
369165
369194
369394
370155
370157
Coupler (S/N 2052462 & Below)
Coupling center (S/N 2052462 & Below)
Ball plunger (S/N 2052462 & Below)
Set screw (S/N 2052462 & Below)
Drive Coupling (S/N 2052463 & Above)
Crumb pan, right
Crumb pan, left
Conveyor frame assembly
Pan stop
Conveyor bearing
Not Shown
E
F
G
H
J
K
Idler shaft
Sprocket (includes set screw), Regular Conveyor
Sprocket (includes set screw), Heavy-Duty Conveyor
Set screw
Drive shaft (S/N 2052462 & Below)
Drive shaft (S/N 2052463 & Above)
Hinge
Door assembly (includes N, P, and Q)
Impinger nameplate
Door latch & catch
Door with window (includes N, P, and Q)
Window frame, top
Glass, access window
Window frame, bottom
Retainer, window
L
M
Not Shown
N
O
P
Q
R
S
T
U
W
X
Splice clip, conveyor belt
Conveyor Belt (complete), Regular Conveyor
Conveyor Belt (1 foot section), Regular Conveyor
Conveyor Belt (complete), Heavy-Duty Conveyor
Conveyor Belt (1-Foot Section), Heavy-Duty Conveyor
Y
30
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
Impinger II – Advantage Digital Service Manual - Domestic
31
Download from Www.Somanuals.com. All Manuals Search And Download.
32
Impinger II – Advantage Digital Service Manual - Domestic
Download from Www.Somanuals.com. All Manuals Search And Download.
|