		 KOBE Brand Range Hood   
					Model No.: CH0030SQB (30'')   
					CH0036SQB (36'')   
					CH0042SQB (42'')   
					CH0048SQB (48'')   
					CH-100 SERIES – 18'' HEIGHT   
					INSTALLATION INSTRUCTIONS   
					AND OPERATION MANUAL   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				- READ AND SAVE THESE INSTRUCTIONS -   
					CONTENTS   
					IMPORTANT SAFETY INSTRUCTIONS.................................................................................... 4   
					COMPONENTS OF PACKAGE ................................................................................................. 3   
					INSTALLATION ......................................................................................................................... 4   
					UNDER THE CABINET INSTALLATION .................................................................................6   
					STAND ALONE INSTALLATION.............................................................................................9   
					OPERATING INSTRUCTIONS ................................................................................................ 12   
					MAINTENANCE....................................................................................................................... 13   
					SPECIFICATIONS................................................................................................................... 15   
					MEASUREMENTS & DIAGRAMS............................................................................................ 16   
					PARTS LIST ............................................................................................................................ 22   
					CIRCUIT DIAGRAM................................................................................................................. 26   
					DISCLAIMER........................................................................................................................... 28   
					WARRANTY ............................................................................................................................ 29   
					PRODUCT REGISTRATION.................................................................................................... 30   
					- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -   
					A L L W I R I N G M U S T B E D O N E B Y A P R O F E S S I O N A L A N D I N   
					A C C O R D A N C E W I T H N A T I O N A L A N D L O C A L E L E C T R I C A L C O D E S .   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				IMPORTANT SAFETY INSTRUCTIONS   
					- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -   
					WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,   
					OBSERVE THE FOLLOWING:   
					1) Installation and electrical wiring must be done by qualified professionals and in accordance with all   
					applicable codes and standards, including fire-rated construction.   
					2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden   
					utilities.   
					3) Ducted fans must be vented to the outside.   
					a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE   
					PANEL.   
					b) Clean grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly,   
					make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces   
					or garages.   
					NOTE   
					- 
					This warranty is invalid without an authorized agent’s receipt or if   
					unit is damaged due to misuse, poor installation, improper use,   
					mistreatment, negligence or any other circumstances beyond the   
					control of KOBE RANGE HOODS authorized agents. Any repair   
					carried out without the supervision of KOBE RANGE HOODS   
					authorized agents will automatically void the warranty.   
					- 
					KOBE RANGE HOODS will not be held responsible for any   
					damages to personal property or real estate or any bodily injuries   
					whether caused directly or indirectly by the range hood.   
					WARNING: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE   
					TOP GREASE FIRE:   
					- 
					Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease   
					should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.   
					Always turn hood ON when cooking at high heat.   
					Use high settings on cooking range ONLY when necessary.   
					Do not leave cooking range unattended when cooking.   
					Always use cookware and utensils appropriate for the type and amount of food prepared.   
					Use this unit only in the manner intended by the manufacturer.   
					Before servicing, switch power off at service panel and lock service panel (if possible) to prevent   
					power from switching on accidentally.   
					- 
					- 
					- 
					- 
					- 
					- 
					- 
					Clean ventilating fan frequently.   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				What to Do In The Event Of a Range Top Grease Fire   
					• 
					SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner.   
					KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not   
					go out immediately, EVACUATE THE AREAAND CALL THE FIRE DEPARTMENT or 911.   
					NEVER PICK UP A BURNING PAN – You May Get Burned.   
					DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.   
					Use an extinguisher ONLY if:   
					• 
					• 
					• 
					a) You have a Class A, B, C extinguisher and know how to operate it.   
					b) The fire is small and contained in the area where it started.   
					c) The fire department has been called.   
					d) You can fight the fire with your back to an exit.   
					What to Do If You Smell Gas   
					• 
					• 
					• 
					Extinguish any open flame.   
					Do not try to turn on the lights or any type of appliance.   
					Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company   
					and Fire Department right away.   
					CAUTION   
					1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and   
					vapors.   
					2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion   
					and exhausting of gases through the flue (chimney) to prevent back drafting.   
					3) Follow the heating equipment manufacturer’s guideline and safety standards such as those   
					published by the National Fire Protection Association (NFPA), and the American Society for   
					Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.   
					4) Activating any switch on may cause ignition or an explosion.   
					5) Due to the size and weight of this hood, two people installation is recommended.   
					ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.   
					Disconnect appliance from electric power before servicing.   
					If   
					equipped, the fluorescent light bulb contains small amounts of   
					mercury, which must be recycled or disposed of according to Local,   
					State, and Federal Codes.   
					2 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				COMPONENTS OF PACKAGE   
					(Must keep all material for returns or refunds)   
					RANGE HOOD BOX   
					ꢁKOBE Range Hood – 1   
					ꢂWarranty Registration Card –1   
					ꢃInstructions Manual – 1   
					ꢄBaffle Filter   
					- 2 (30”, 36”, 42”)   
					- 3 (48”)   
					ꢈ 
					ꢉ 
					ꢅStainless Steel Spacer   
					- 2 (30”)   
					DUCT COVER KIT (Sold Separately)   
					- 2 (36”)   
					- 3 (42”)   
					- 2 (48”)   
					Option Of:   
					Model No. CH0030DC-12 for 30'' hood   
					KOBE Duct Cover – 1   
					ꢆOil Tunnel – 1   
					ꢇDucting Transition – 1   
					Screw Package for Transition – 1   
					ꢈHood-Mounting Bracket-2   
					Screw Package for Duct Cover - 1   
					Model No. CH0036DC-12 for 36'' hood   
					KOBE Duct Cover – 1   
					ꢉScrew Package for Hood-Mounting Bracket w/   
					Rubber Stand –1   
					Screw Package for Duct Cover - 1   
					ꢁ 
					ꢂ 
					Model No. CH0042DC-12 for 42'' hood   
					KOBE Duct Cover – 1   
					Screw Package for Duct Cover - 1   
					Model No. CH0048DC-12 for 48'' hood   
					KOBE Duct Cover – 1   
					Screw Package for Duct Cover - 1   
					ꢃ 
					ꢄ 
					ꢅ 
					3/16" X 3/8" (8 pc)   
					ꢆ 
					ꢇ 
					ꢀ OPTIONAL RECIRCULATING KIT ALSO AVAILABLE.   
					ꢀ FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE   
					WWW.KOBERANGEHOODS.COM OR CONTACT KOBE RANGE HOODS AT (626) 350-1355.   
					3 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				INSTALLATION   
					PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING   
					Calculation before Installation   
					To calculate installation, please refer to Table 1. (All calculation in inches.)   
					- FOR UNDER THE CABINET -   
					TABLE 1   
					A = Height of Floor to Ceiling   
					B = Height of Floor to Counter Top   
					(Standard: 36”)   
					C = Height of Counter Top to Hood Bottom   
					(Recommended 27'' to 30'')   
					[(A – B) – (D + E)]   
					D = Height of Hood   
					E = Height of the Cabinet   
					- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) -   
					TABLE 2   
					A = Height of Floor to Ceiling   
					B = Height of Floor to Counter Top   
					(Standard: 36”)   
					C = Height of Counter Top to Hood Bottom   
					(Recommended 27'' to 30'')   
					D = Height of Hood   
					E - Height of Duct Cover   
					F = Height of the Hood Installation   
					[A – (B+C)]   
					4 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SAFETY WARNING   
					HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF   
					REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.   
					NOTE: USING ELECTRICAL SCREWDRIVERS MAY CAUSE DAMAGE TO THE HOOD.   
					Installation Table of Contents   
					UNDER THE CABINET INSTALLATION................................................................................6   
					Preparation Before Installation................................................................................................6   
					Hood Installation ........................................................................................................................6   
					Ductwork Installation.................................................................................................................7   
					Wiring to Power Supply.............................................................................................................7   
					Final Assembly ...........................................................................................................................7   
					STAND ALONE INSTALLATION ...........................................................................................9   
					Preparation Before Installation................................................................................................9   
					Hood Preparation Before Installation.....................................................................................9   
					Hood Installation ........................................................................................................................9   
					Wiring to Power Supply...........................................................................................................10   
					Duct Cover Installation............................................................................................................11   
					Final Assembly .........................................................................................................................11   
					5 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				UNDER THE CABINET INSTALLATION   
					Preparation Before Installation   
					NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT   
					DEBRIS FROM ENTERING THE VENT OPENING.   
					• 
					• 
					• 
					Decide the location of the venting pipe from the hood   
					to the outside. Refer to Figure 1.   
					A straight, short vent run will allow the hood to   
					perform more efficiently.   
					Try to avoid as many transitions, elbows, and long   
					run as possible. This may reduce the performance   
					of the hood.   
					Figure 1   
					• 
					• 
					Temporarily wire the hood to test for proper operation   
					before installing.   
					Important: Peel protective film off the hood, if   
					any.   
					• 
					• 
					Use duct tape to seal joints between pipe sections.   
					For installing under the cabinet with recessed   
					bottom, attach 4-inch wide wood filler strips (not   
					included) on each side. Refer to Figure 2.   
					Using references in TABLE 1 on page 4 and   
					Measurements and Diagrams on page 18, create   
					access opening for electrical wires and hood exhaust   
					under the cabinet.   
					• 
					Figure 2   
					Hood Installation   
					CAUTION: If moving the cooking range is necessary   
					to install the hood, turn off the power on an electric   
					range at the main electrical box. SHUT OFF THE GAS   
					BEFORE MOVING A GAS RANGE.   
					1. Puncture the knockout holes (for mounting under the   
					cabinet) on the hood as shown in Figure 3.   
					2. Attach ducting transition to hood exhaust with ten   
					(3/16” x 3/8”) screws (included). Shown in Figure 4.   
					3. If necessary, attach two rubber stands (included) with   
					adhesive tape (included) to the back corners of the   
					hood.   
					Figure 3   
					4. Draw electrical wires through cabinet access opening.   
					5. Center the hood beneath the cabinet and flush with the   
					front of the cabinet.   
					6. From inside of the hood, place screw (not included)   
					into the center of each knockout hole and secure to   
					cabinet bottom. Once all mounting screws are in place,   
					finish tightening screws until secure.   
					CAUTION:   
					MAKE SURE HOOD IS SECURE BEFORE   
					RELEASING.   
					7. For safety purpose, pre-drilled mounting holes are   
					provided through the back of the hood. For a more   
					secure installation, use as many mounting holes as   
					needed to secure from the inside of hood (screws not   
					included).   
					Figure 4   
					6 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Ductwork Installation   
					8. Use 8” round steel pipe (follow building codes in your   
					area) to connect the ducting transition on the hood to   
					the ductwork above. Use duct tape to make all joints   
					secure and air tight. Refer to Figure 5.   
					Wiring to Power Supply   
					S AFE TY W ARNING   
					RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD   
					MUST BE PROPERLY GROUNDED. MAKE SURE THIS   
					Figure 5   
					IS   
					DONE   
					BY   
					QUALIFIED   
					ELECTRICIAN   
					IN   
					ACCORDANCE WITH ALL APPLICABLE NATIONAL   
					AND LOCAL ELECTRICAL CODES.   
					BEFORE CONNECTING WIRES, SWITCH POWER OFF   
					AT SERVICE PANEL TO PREVENT POWER FROM   
					BEING SWITCHED ON ACCIDENTALLY.   
					9. Connect electrical wires.   
					- 
					Connect three wires (black, white and green) to   
					house wires and cap with wire connectors.   
					Connect wires according to their colors (i.e. black to   
					black, white to white, and green to green). See   
					Figure 6.   
					Figure 6   
					- 
					Store wires in the wiring box.   
					Final Assembly   
					CAUTION: Install heating lamps last.   
					10. Drop oil tunnel into recess support near rear of hood.   
					Refer to Figure 7.   
					11. Install baffle filters and stainless spacer(s). Refer to   
					Measurements and Diagrams on page 21 for baffle   
					filter and stainless spacer placement. Angle baffle filter   
					toward back of hood ꢁ. Push baffle filter up until   
					almost level ꢂ. Slide forward into recess behind the   
					front of hood ꢃ. Lower baffle filter ꢄ. Slide back until   
					it fits into resting position ꢅ. Refer to Figure 8.   
					12. Repeat for all baffle filters and spacers.   
					Figure 7   
					13. Install heating lamps (not included), 120 Volts 175   
					Watts max. each.   
					7 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				14. Turn power ON in control panel. Check all lights and   
					fan operation.   
					15. Make sure to leave this manual for the homeowner   
					Figure 8   
					8 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WALL MOUNT INSTALLATION   
					***Follow these installations only if installing with an optional duct cover:   
					Preparation Before Installation   
					NOTE: TO AVOID DAMAGE TO YOUR HOOD,   
					PREVENT DEBRIS FROM ENTERING THE   
					VENT OPENING.   
					• 
					• 
					• 
					Decide the location of the venting pipe from the   
					hood to the outside. Refer to Figure 9.   
					A straight, short vent run will allow the hood to   
					perform more efficiently.   
					Try to avoid as many transitions, elbows, and long   
					run as possible. This may reduce the performance   
					of the hood.   
					Figure 9   
					• 
					• 
					• 
					Use duct tape to seal the joints between pipe   
					sections.   
					If necessary, prepare back wall frame with cross   
					framing lumber for secure installation.   
					Using references in Table 2 on page 4 and   
					Measurements and Diagrams on pages 19-20,   
					decide the level of the lumber. Refer to Figure 10.   
					Hood Preparation Before Installation   
					Figure 10   
					• 
					• 
					• 
					Temporarily wire the hood to test for proper   
					operation before installing.   
					Important: Peel protective film off the hood   
					and the duct cover (if any).   
					Attach ducting transition to hood exhaust with ten   
					(3/16” x 3/8”) screws (included). Refer to Figure   
					11.   
					• 
					• 
					If necessary, attach two rubber stands (included)   
					with adhesive tape (included) to the back corners   
					of the hood.   
					Use eight (3/16” x 3/8”) screws (included) to attach   
					the two hood-mounting brackets (included) to the   
					back of the hood. Refer to Figure 12.   
					Figure 11   
					Hood Installation   
					CAUTION: If moving the cooking range to   
					install the hood is necessary, turn off the   
					power on an electric range at the main   
					electrical box. SHUT OFF THE GAS BEFORE   
					MOVING A GAS RANGE.   
					1. Using references in Table 2 on page 4 and   
					Measurements and Diagrams on pages 19-20,   
					Figure 12   
					9 
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				mark the leveling point of the hood. Position two   
					mounting screws (not included) on the wall,   
					leaving 1/8” away from the wall. Refer to Figure 13   
					2. Align hood-mounting bracket to the two screws   
					on the wall and hook hood into place. Tighten   
					screws to secure hood to the wall.   
					WALL   
					3. For safety purpose, pre-drilled mounting holes   
					are provided through the back of the hood. For a   
					more secure installation, use as many mounting   
					holes as needed to secure from the inside of   
					hood (screws not included).   
					CAUTION: MAKE SURE HOOD IS SECURE   
					BEFORE RELEASING.   
					Figure 13   
					Wiring to Power Supply   
					SAFETY WARNING   
					RISK OF ELECTRICAL SHOCK. THIS RANGE   
					HOOD MUST BE PROPERLY GROUNDED. MAKE   
					SURE THIS IS DONE BY QUALIFIED ELECTRICIAN   
					IN ACCORDANCE WITH ALL APPLICABLE   
					NATIONAL AND LOCAL ELECTRICAL CODES.   
					BEFORE CONNECTING WIRES, SWITCH POWER   
					OFF AT SERVICE PANEL AND LOCK SERVICE   
					PANEL TO PREVENT POWER FROM BEING   
					SWITCHED ON ACCIDENTALLY.   
					Figure 14   
					4. Connect the electrical wires.   
					- 
					Connect three wires (black, white and green)   
					to house wires and cap with wire connectors.   
					Connect according to color: black to black,   
					white to white, and green to green as shown   
					in Figure 14.   
					- 
					Store wires in the wiring box.   
					10   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Duct Cover Installation   
					5. Use 8” round steel pipe (follow building codes in   
					your area) to connect the ducting transition on   
					the hood to the ductwork above. Use duct tape   
					to make all joints secure and air tight. Refer   
					Figure 15. Slide the duct cover onto the hood.   
					6. Use 3/16” x 3/8” screws (included) to attach duct   
					cover to hood.   
					Figure 15   
					Final Assembly   
					CAUTION: Install heating lamps last.   
					7. Drop oil tunnel into recess support near rear of   
					hood. Refer to Figure 16.   
					8. Install baffle filters and stainless spacer(s).   
					Refer to Measurements and Diagrams on page   
					21 for baffle filter and stainless spacer placement.   
					Angle baffle filter toward back of hood ꢁ. Push   
					baffle filter up until almost level ꢂ. Slide forward   
					into recess behind the front of hood ꢃ. Lower   
					baffle filter ꢄ. Slide back until it fits into resting   
					position ꢅ.Angle baffle filter toward back of hood   
					Figure 16   
					ꢁ 
					. Refer to Figure 17.   
					9. Repeat for all baffle filters and spacers.   
					10. Install heating lamps (not included), 120 Volts   
					175 Watts max. each.   
					11. Turn power ON in control panel. Check all   
					lights and fan operation.   
					12. Make sure to leave this manual for the   
					homeowner.   
					Figure 17   
					11   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				OPERATING INSTRUCTIONS   
					This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30-   
					second delay shutoff, powerful centrifugal squirrel cage with baffle filters, bright 12-volt 20-watt halogen   
					lights, and heating lamp sockets (lamps not included).   
					The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control   
					(On/Off). Refer to Figure 18.   
					Figure 18   
					Light Control   
					Power Control   
					Speed Control B   
					Speed Control A   
					TURN ON:   
					• 
					Press Power Control (On/Off) button once.   
					(Note: If any Control button is not pressed within 10 seconds, power will be automatically   
					turned off).   
					• 
					• 
					The KOBE hood will start on Low speed. Each press of the Speed Control button will   
					cycle through the various speeds.   
					Press Speed Control A button to cycle from Low, QuietMode, High, or Medium.   
					Press Speed Control B button to cycle from Low, Medium, High or QuietMode.   
					(Note: Speed Control A or B will operate both fans. These two speed buttons will allow you   
					to change the speed quicker.)   
					• 
					• 
					Press Light Control button to turn halogen light on. The light has three settings: High,   
					Low and Off   
					Press the back Red button to turn on heating lamp.   
					(Note: Heating lamps are sold separately. Heating lamps required 120-volt, 175-watt.)   
					TURN OFF:   
					• 
					Press Power Control (On/Off) button once, panel lights will flash and power will be   
					completely shut off after 3 minutes.   
					OR   
					• 
					• 
					Press Power Control (On/Off) button twice, all power will be shut off immediately.   
					If only the lights are on, pressing Power Control (On/Off) button once will turn power   
					off after 30 seconds.   
					12   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				MAINTENANCE   
					SAFETY WARNING   
					NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS   
					OPERATING.   
					For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly.   
					To Clean Hood Surface   
					CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.   
					*** Regular care will help preserve the appearance of the hood.   
					1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth.   
					2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface   
					of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of   
					the stainless steel cleaner.   
					Caution: Do not leave on too long as this may cause damage   
					to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn   
					spots. Use dry soft towel to dry the hood.   
					3. DO NOT allow deposits to accumulate or remain on the hood.   
					4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface   
					and cause rusting.   
					5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in   
					contact with stainless steel for extended periods. Many of these compounds contain chemicals,   
					which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.   
					To Clean Baffle, Spacer, Filter, Oil Tunnel and Oil Container   
					CAUTION: DRAIN OIL FROM BAFFLES, SPACER(S), FILTERS, OIL TUNNEL(S) AND OIL   
					CONTAINERS BEFORE OIL AND RESIDUE CAN OVERFLOW.   
					1. Remove all baffles, spacer(s), filters, oil tunnel(s), and oil containers. Follow directions for   
					installation in reverse.   
					2. Discard oil and residue.   
					3. Wash with warm soapy water. Dry thoroughly before replacing.   
					(Note: Stainless Steel Baffles, Stainless Steel Spacer(s) & Stainless Steel Oil Tunnel are top   
					rack dishwasher safe.)   
					13   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				To Replace Light Bulb   
					CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.   
					ꢁ 
					ꢂ 
					ꢃ 
					ꢄ 
					1. Make sure all controls are off, and range hood is unplugged.   
					2. Place a flat-head screwdriver between light cover and housing ꢁ to remove cover ꢂ.   
					3. Gently pull defective bulb straight out ꢃ and discard. Light bulbs should be 12V 20W   
					maximum.   
					4. Wear a cotton glove or use a cloth to handle the replacement bulb (do not handle with bare   
					fingers as this may shorten the life of the bulb). Push gently but securely into light socket.   
					NOTE: DO NOT PUSH TOO HARD AS BULB “LEGS” MAY BREAK OFF.   
					5. Replace light cover ꢄ.   
					6. Turn range hood ON to test for operation.   
					14   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				SPECIFICATIONS   
					MODEL / SIZE   
					CH0030SQB / 30”   
					CH0036SQB / 36”   
					CH0042SQB / 42”   
					CH0048SQB / 48”   
					DESIGN   
					18-Gauge Seamless Commercial Stainless Steel   
					CONSUMPTION / AMPERE   
					702W / 5.85A – 30”, 36”   
					722W / 6.02A – 42”, 48”   
					120V 60Hz   
					VOLTAGE   
					NUMBER OF MOTORS   
					FAN TYPE: CENTRIFUGAL   
					EXHAUST   
					1 
					Squirrel Cage   
					Top Transition Rectangular to 8” Round x 1   
					CONTROLS   
					Electronic Control (4 Buttons) –   
					10-Second Standby Startup   
					3-Minute Delay Shutoff   
					HALOGEN LIGHTS   
					30” / 36” - 12V20W x 2   
					42” / 48” - 12V20W x 3   
					HEATING LAMP SOCKET   
					120V 175W Max. x 2 (Lamps Not Included)   
					(CH0030SQB) 29-3/4” x 24” x 18”   
					(CH0036SQB) 35-3/4” x 24” x 18”   
					(CH0042SQB) 41-3/4” x 24” x 18”   
					(CH0048SQB) 47-3/4” x 24” x 18”   
					Original Kit ---Duct Cover   
					HOOD DIMENSION   
					(W X D X H)   
					OPTIONAL ACCESSORIES (Not Included)   
					(W X D X H)   
					(CH0030DC-12) – 30” x 12” x 12”   
					(CH0036DC-12) – 36” x 12” x 12”   
					(CH0042DC-12) – 42” x 12” x 12”   
					(CH0048DC-12) – 48” x 12” x 12”   
					Stainless Steel Back Panel   
					(SSP 30) 30” x 1/10” x 32”   
					(SSP 36) 36” x 1/10” x 32”   
					HOOD WEIGHT (lbs)   
					Net   
					70   
					75   
					84   
					92   
					Gross   
					84   
					(CH0030SQB)   
					(CH0036SQB)   
					(CH0042SQB)   
					(CH0048SQB)   
					QuietMode™   
					400   
					93   
					104   
					115   
					Blower Air Capacity (cfm)*   
					Sone**   
					Low   
					600   
					3.5   
					Medium   
					800   
					High   
					1000   
					8.0   
					1.4   
					7.0   
					*In House Test. HVI Standard.   
					**Specifications subject to change without notice.   
					15   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				MEASUREMENTS & DIAGRAMS   
					ꢊ All ( ) are in millimeter.   
					ꢊ All inch measurements are converted from millimeters. Inch measurements are estimated.   
					- FOR UNDER THE CABINET -   
					MODEL NO: CH0030SQB   
					CH0036SQB   
					CH0042SQB   
					CH0048SQB   
					16   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				- FOR UNDER THE CABINET – (Cont.)   
					17   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) –   
					MODEL NO: CH0030SQB   
					CH0036SQB   
					CH0042SQB   
					CH0048SQB   
					18   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Rear Knockout Holes   
					19   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				- FOR WALL MOUNT (WITH OPTIONAL DUCT COVER) – (Cont.)   
					20   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Hood-Mounting Bracket   
					1" (25.4)   
					1/4" (6.5)   
					6" (152)   
					7 - 1/2" (190.5)   
					BAFFLE FILTER & STAINLESS STEEL SPACERS   
					30"HOOD   
					42"HOOD   
					36"HOOD   
					48"HOOD   
					21   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				PARTS LIST   
					MODEL NO:   
					CH0030SQB   
					CH0036SQB   
					CH0042SQB   
					CH0048SQB   
					BODY COMPONENTS   
					NO.   
					1 
					DESCRIPTION   
					Hood Casing   
					MODEL/SIZE   
					PART NO.   
					CH100-1   
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					A 
					B 
					C 
					D 
					18   
					19   
					20   
					21   
					22   
					23   
					Ducting Transition   
					Screws (3/16” x 3/8”)   
					Blower Assembly   
					Wiring Box Cover   
					Wiring Box   
					Heat Lamp Socket   
					Screws (3/16” x 3/8”)   
					Heat Lamp Socket Box   
					Oil Tunnel   
					Heat Lamp Panel   
					Halogen Light Panel   
					Halogen Light   
					Screws (3/16” x 3/8”)   
					Gasket   
					CH100-2   
					CH100-3   
					CH100-4   
					CH100-5   
					CH100-6   
					CH100-7   
					CH100-8   
					CH100-9   
					CH100-10   
					CH100-11   
					CH100-12   
					CH100-13   
					CH100-14   
					CH100-15   
					CH100-16   
					Baffle Filter   
					Stainless Steel Spacer   
					CH0030SQB   
					CH100-17-1   
					CH100-17-2   
					CH100-17-2   
					CH100-17-2   
					CH100-18   
					CH100-19   
					CH100-20   
					CH100-21   
					CH100-14   
					CH100-23   
					CH0036SQB   
					CH0042SQB   
					CH0048SQB   
					Baffle Handle   
					Screws (3/16” x 3/8”)   
					Switch Assembly   
					Electrical Assembly   
					Screws (3/16” x 3/8”)   
					Hood-Mounting Bracket   
					Optional Duct Cover (Sold Separately)   
					ORIGINAL KIT   
					NO.   
					24   
					DESCRIPTION   
					Duct Cover   
					MODEL/SIZE   
					PART NO.   
					CH0030DC-12   
					CH0036DC-12   
					CH0042DC-12   
					CH0048DC-12   
					3 
					Screws (3/16” x 3/8”)   
					22   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3 
					2 
					1 
					4 
					5 
					23   
					22   
					6 
					7 
					21   
					18   
					9 
					3 
					8 
					20   
					16   
					19   
					10   
					11   
					15   
					17A   
					14   
					17B   
					17C   
					17   
					17D   
					12   
					13   
					Optional Duct Cover (Sold Separately)   
					24   
					3 
					23   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Blower Assembly   
					NO.   
					4.1   
					4.2   
					4.3   
					4.4   
					4.5   
					4.6   
					4.7   
					4.8   
					DESCRIPTION   
					Screws (3/16” x 3/8”)   
					Air Flow Grill   
					Left Locknut   
					Left Squirrel Cage   
					Motor   
					Right Squirrel Cage   
					Right Locknut   
					Air Chamber   
					MODEL / SIZE   
					PART NO.   
					CH100-4.1   
					CH100-4.2   
					CH100-4.3   
					CH100-4.4   
					CH100-4.5   
					CH100-4.6   
					CH100-4.7   
					CH100-4.8   
					24   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Electrical Assembly   
					NO.   
					21.1   
					21.2   
					21.3   
					21.4   
					21.5   
					21.6   
					21.7   
					21.8   
					21.9   
					DESCRIPTION   
					Capacitor   
					Electrical Box   
					Screws (3/16” x 3/8”)   
					Processor Board   
					Electrical Box Cover   
					Setup Board   
					Screws (3/16” x 3/8”)   
					Transformer   
					MODEL / SIZE   
					PART NO.   
					CH100-21.1   
					CH100-21.2   
					CH100-21.3   
					CH100-21.4   
					CH100-21.5   
					CH100-21.6   
					CH100-21.7   
					CH100-21.8   
					CH100-21.9   
					Screws (3/16” x 3/8”)   
					21.2   
					21.9   
					21.3   
					21.4   
					21.5   
					21.1   
					21.8   
					21.6   
					21.7   
					25   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				CIRCUIT DIAGRAM   
					MODEL NO.: CH0030SQB   
					CH0036SQB   
					CONTROL BOARD   
					PROCESSOR BOARD   
					RED   
					BLACK   
					HALOGEN LIGHT   
					120V 60Hz   
					MOTOR   
					TRANSFORMER   
					CAPACITOR   
					10uF/450V   
					26   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				MODEL NO.: CH0042SQB   
					CH0048SQB   
					CONTROL BOARD   
					PROCESSOR BOARD   
					RED   
					BLACK   
					HALOGEN LIGHT   
					120V 60Hz   
					MOTOR   
					TRANSFORMER   
					CAPACITOR   
					10uF/450V   
					27   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				DISCLAIMER   
					1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING DELIVERY. NOTE   
					ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS RECEIPT. REQUEST NAME AND   
					SIGNATURE OF THE CARRIER’S AGENT AND KEEP COPY TO SUPPORT YOUR CLAIM.   
					Upon acceptance of items, owner assumes responsibility for its safe arrival. Report damages to the   
					carrier and file a claim immediately. Failure to do so may result in the denial of your claim. The   
					carrier will furnish you with necessary forms for filing a claim.   
					DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR WARRANTY.   
					2. PLEASE INSPECT CONTENTS OF PACKAGE(S) CAREFULLY UPON RECEIVING!   
					We must be notified in writing of any damages and/or missing parts within the allocated days upon   
					your receipt of package(s). Contact your local KOBE dealer or distributor or call KOBE for the time   
					limit.   
					CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.   
					NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR FACTORY   
					BEFORE SHIPPING.   
					3. Products must be returned in good working condition with ALL original parts and documentation   
					packed in ALL original cartons, fillers and shipping cartons. A restocking fee of 25% will be charged   
					for all approved return(s).   
					EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS MISSING.   
					4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE   
					INSTALLATION. Appearance flaws of the hood found after installation and not affecting hood   
					performance is not covered under our warranty for returns or exchanges. Service visits not covered   
					under warranty will carry a service charge.   
					A)   
					B)   
					Before Installation: Return for exchange or refund (please see above for acceptable   
					returns).   
					After Installation:   
					NO exchange or refund.   
					28   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				WARRANTY   
					WARRANTY CERTIFICATE   
					KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in   
					workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two   
					years from the date of purchase and to the repair or replacement at its option and subject to the terms   
					and conditions stated below, of any component part, which its examination shall disclose to be so   
					defective.   
					TWO-YEAR WARRANTY SERVICE PERIOD   
					Any covered failure occurring within two years of original purchase arising from defective workmanship   
					or material in manufacture will be repaired (or at our discretion, replaced) free of charge by an   
					authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase   
					(or original invoice) handy for inspection.   
					If the range hood is sold by the original purchaser during the warranty period the new owner is   
					protected until expiration of the original purchaser’s warranty.   
					CONDITIONS   
					The following conditions apply only in relation to the warranty expressly given in this certificate.   
					1) This warranty applies only:   
					a) within U.S.A. and Canada.   
					b) to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or   
					MULTIPLE FAMILY USE or other purposes, warranty will be voided).   
					2) Repair of any fault to be provided under this warranty shall not be provided:   
					a) if the identification number attached to the range hood has been altered, rendered illegible or   
					removed;   
					b) if notice of the defect has not been given within the period applicable;   
					c) for failure of light bulbs or heat lamps;   
					d) for physical damage;   
					e) for surfaces damaged by use of improper chemical cleaning agents;   
					f) if the appliance has been:   
					i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to follow the   
					operating instructions;   
					ii) connected to improper, inadequate or faulty electricity service or exhaust ducts, flues or duct   
					cover, or operated using incorrect or contaminated lubricants;   
					iii) installed, maintained or operated otherwise than in accordance with the instructions   
					furnished by KOBE Range Hoods including the improper use of detergents, bleaches, or   
					cleaners.   
					g) for damage to range hood during transit, delivery, installation or removal;   
					h) for damage by or resulting from attempted repairs conducted by anyone other than our   
					Authorized Service Agent.   
					29   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				3) The purchaser shall be responsible for any expenses involved in making the range hood readily   
					accessible for servicing and where the range hood is installed outside the main sales territory of the   
					retailer or service territory of the nearest approved KOBE Range Hoods Agent as applicable, for any   
					traveling expenses and any costs of transporting the range hood or parts thereof to and from the   
					dealer or Service Agent   
					4) The purchaser must produce proof of purchase together with this warranty certificate when making   
					the claim.   
					5) Damages caused during shipment are not covered under our warranty.   
					CONSEQUENTIAL DAMAGE   
					The warrantor is not responsible for any consequential damage. SOME STATES DO NOT ALLOW   
					THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION MAY NOT APPLY   
					TO YOU.   
					IMPLIED WARRANTIES/STATE LAW   
					Any implied warranties, including the implied warranty of merchantability and fitness for purpose,   
					imposed on the sale by the laws of the state of sale are limited to two year from the date of original   
					purchase. Some states do not allow limitations on the duration of implied warranties. This warranty   
					gives you specific legal rights, and may also have rights, which vary from state to state.   
					SERVICE   
					For service contact:   
					KOBE Range Hoods   
					10505 Valley Blvd, Suite 302   
					EI Monte, CA 91731   
					U.S.A   
					Tel: (626) 350-1355 Fax: (626) 350-1976   
					Email:   
					Website:   
					
					
					30   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				PRODUCT REGISTRATION   
					Register Your Product!   
					Any covered failure occurring within two years of original purchase arising from defective   
					workmanship or material in manufacture will be repaired or at our option the unit will be replaced   
					free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable.   
					Keep proof of purchase (original invoice) handy for inspection.   
					If the range hood is sold by the original purchaser during the warranty period the new owner is   
					protected until expiration of the original purchaser’s warranty. See warranty section for complete   
					warranty coverage information.   
					This appliance has been manufactured, tested, and inspected to the standards required by KOBE   
					Range Hoods.   
					PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND PROOF OF PURCHASE   
					TO:   
					KOBE Range Hoods   
					10505 Valley Blvd Suite # 302   
					El Monte, CA 91731 USA   
					RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD:   
					Model No. ________________________   
					Serial No. ________________________   
					Purchased Date   
					Purchased From:   
					_____/_____/_____   
					______________________________   
					______________________________   
					______________________________   
					IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY WHEN   
					REQUESTING SERVICE.   
					31   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				{THIS PAGE LEFT PURPOSELY BLANK}   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				KOBE Range Hoods   
					10505 Valley Blvd Suite # 302   
					El Monte, CA 91731 USA   
					
					This KOBE hood is manufactured for use in the USA and CANADA only. We do   
					not recommend using this hood overseas as the power supply may not be   
					compatible and may violate the electrical code of that country. Using a KOBE   
					hood overseas is at your own risk and will void your warranty.   
					VER.070601   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				 |