| Herculine 11280S   Smart Actuator   61-86-03-13   9/01   Page 1 of 14   Specification   Overview   Honeywell’s HercuLine 11280S Smart   actuators incorporate all of the high   quality and reliable features of the   traditional HercuLine actuators plus   the added benefits of a microprocessor-   based Enhanced Electronics Unit (EEU).   These additional benefits provide:   • • • Faster set-up and commissioning   Network capability   Health parameter monitoring for   proactive maintenance planning.   HercuLine 11280S Smart actuators   enable operation at maximum process   efficiency, minimal downtime, and   access to all actuator parameters for   real-time business decisions.   Honeywell’s 11280S actuators are   industrial rated and engineered for very   precise positioning of dampers and   valves. The HercuLine 11280S   performs especially well in extremely   demanding environments requiring   continuous duty, high reliability, and low   maintenance. Typical applications are   ID/FD fan dampers, furnace pressure   dampers, coal mill dampers, burner tilts   and more.   Figure 1 Herculine 11280S Smart Actuator   • Full Travel Speed – Full stroke   travel speeds as fast as 10   seconds.   Control options are available to   interface with a modulating 4-20 mA   input signal and 4-20 mA customer   feedback or remote setpoint through   Modbus. Internal balance, customer   feedback and patented slidewire   emulation is provided by a non-   contacting position sensor.   • • • • Torque – High torque capability in   small package (425 – 5,500 lb-ft).   Actuator Operation   High Accuracy – Typically 0.25 %   of 90° span.   Microprocessor-based electronics   continually monitor the performance,   health, and position of the actuator for   repeatable positioning and response to   demand signal.   High Repeatability - Typically   0.2 % of 90° span.   Features   Characterization – Linear, square   root or programmable user-   configured 21-point   characterization allows tailoring of   control for specific applications.   Performance    • Accurate Positioning –   Motor/gear train provides accurate   positioning with almost   instantaneous start/stop   characteristics.   A double reduction worm gear set   combines with a variable speed motor   controller (inverter) that is continuous   duty rated for accurate and repeatable   positioning of final control elements.   • • Input Filter Setting – Four   programmable combinations of   input filter settings are provided to   accommodate various customers   needs. The combinations are   none, spike, low pass, or spike +   low pass filter.   • • Non-Contact Position Sensing –   Non-contacting sensing lowers   maintenance costs and improves   performance.   The worm gear set combination also   functions as a brake, capable of holding   greater than two times the output torque   in a back-driving condition.   Duty Cycle – Continuous duty   Deadband – Deadband is   programmable between 0.2 % to   5 % of 90° span.   rated motor.   Sensing and Control, 11 West Spring Street, Freeport, Illinois 61032   Printed in U.S.A. © Copyright 2000—Honeywell   61-86-03-13   Page 3   Local Display and Keypad   Configuration and set-up is through the local HMI, consisting of a display and keypad interface (Figure 2). A high intensity   10-character LED display and simple pushbuttons provide quick access for actuator set up and status information. If relay   outputs are specified, all configuration can be done through either the local HMI interface. If mechanical switches are   specified, then the user must manually set the auxiliary output.   Control Arm Rotation   Indicators   CCW   CW   STALLED   LED Status   Indicators   ALARM   Upper Display   (Four Characters)   MANUAL   AUTO   Lower Display   (Six Characters)   SET UP   FUNCTION   DISPLAY   MAN/AUTO   Pushbuttons to   Access Actuator   Set Up, Status and   Calibration   Parameters.   Figure 2 Local HMI (Display and Keypad)   Non-Contact Sensor   Sensing PWA   Non-Contact Sensor Spoiler   Figure 3 Non-Contact Sensor Assembly   61-86-03-13   Page 4   Set Up/Configuration Parameters   Configuration parameters are logically grouped and accessed using the local HMI. Actuator calibration is also   accomplished through a simple procedure using the keypad. By pressing the SETUP button on the HMI, you can step   through the set up groups that contain all of the configuration parameters. The table below summarizes the configuration   parameters available within the various set up groups. Full details of all configuration parameters are found in the 11280S   Series Smart Actuator Installation, Operation and Maintenance Manual, document number 61-86-25-09.   Set Up Group   Configuration Parameter Selections/Settings   IN TYP – Input Actuation Type   Dband – Input Deadband   FsTYP – Failsafe Type   SET INPUT Selects various   parameters that define actuator   operation.   INP HI – Input High Range Value   INP LO – Input Low Range Value   FILTYP – Input Filter Type   FsVAL – Failsafe Value   CHAR – Input Characterization   LDCAL – Restore Calibration Type   LPFILT – Low Pass Filter Time Constant   Direct – Actuator Rotation   RTYPnn – Relay Type   RnnE – Relay Count Multiplier   RnnVAL – Relay Value   SET RELAY When the actuator   is equipped with optional relays,   this set up group allows you to set   relay action for various actuator   operating conditions. Contact   closure can be wired to external   annunciators or alarm points to   indicate conditions for any of the   Relay Types.   Input Range   Position Range   Deviation   Upper or Lower Limit Travel   Temperature High or Low   Motor Starts   Motor Stalled   Manual Mode   Rnn HL – Relay High/Low   RLYnHY – Relay Hysteresis   Power Up Test Failure   Input Signal Failure   Position Sensor Signal Failure   Digital Input Closure   CUROUT - Output Signal Range   SET CUROUT Selects the   current (or voltage) output range   of the actuator.   4 – 20 mA,   1 – 5V,   0 – 20 mA,   0 – 5V,   SW E (Slidewire Emulation)   COMM – Communications Parameters   ADDRES – Device Address   BAUD – Baud Rate   SET COMM Actuator can be   defined as a master or slave   device on a Modbus RTU RS-485   loop. Operating setpoint can be   transmitted to the actuator and   operating status can be read   when connected to supervisory   control systems.   XmtDLY – Response Delay   DBLBYT – Floating Point Data Format   DIGINP – Digital Input State   Endpos – End Position Value   SET DIGINP Selects digital   input action upon contact closure.   DECMAL – Decimal Point Location   EUNITS – Units Display   SET DISPLA Selects desired   decimal places and engineering   units for local display.   UNITS – Display Units   CAL INPUT, MTR, CURENT If needed, calibration of the actuator input, motor position and actuator output can be   performed using the local keypad and display.   Continued on next page ⇒   61-86-03-13   Page 5   Set Up Group   Configuration Parameter Selections/Settings   LOCKID – Set Security Password   SET LOCK Enables lock   out or access to selected   set up group parameters   and calibration values.   LOCK – Lock Out   FAILSF – Failsafe   CFGTST – Configuration Test Diagnostic   READ STATUS   Displays failsafe condition   and the results of various   diagnostics performed   during power up.   RAMTST – RAM Test Diagnostic   CALTST – Calibration Test Diagnostic   SEETST – Serial EEPROM Test   Diagnostic   VERSON – Firmware Version   SPEED – Stroke Speed   MFGDAT – Manufacturing Date   LREP – Date of Last Repair   LCAL – Date of Last Field Calibration   REPTYP – Repair Type   SET DRVINF Allows   access to actuator device   information.   POWER – Power Input Voltage and Line   Frequency   TAG – Tag Name   TEMP – Actuator Temperature   TEMPHI – High Temperature Limit   TEMPLO – Low Temperature Limit   ACST – Accumulated Motor Stall Time   STARTS – Accumulated Motor Starts   RLnCNTS – Relay Cycle Counts   SET MAINT Allows   access to parameters that   monitor operating   conditions.   REGNn – Accumulated Motor Starts   (Regions of Travel)   TOTDEG – Total Degrees of Motor Travel   MANRST – Reset Maintenance Statistics   Specifications – General   Physical   Enclosure   Precision-machined ductile iron with corrosion resistant paint   Precision-machined double reduction worm gear   Gear Train   -30 °C to +65 °C (-20 °F to +150 °F)   Operating Temperature   except Model 11287S which has a range of: -20 °C to +65 °C (-4 °F to +150 °F)   -40 °C to +93 °C (-40°F to +200 °F)   Storage Temperature   Relative Humidity   Crank Arm   0-99% R.H. noncondensing, over the full operating temperature range.   Adjustable radii (8” to 14”) crank arm is standard   Factory set to 90 degrees, for 0% to 100% travel   Rotation   Field programmable via local display and keypad   Direction of Rotation   Manual Handwheel   Lubrication   Provides a means of positioning the actuator in the event of a power failure or set-up   Mobil Synthetic bearing and gear lubricant SHC 634 (ISO 460) or equivalent   300 lb to 600 lb (136 kg to 272 kg)—See Table below for more information.   Weight   Specifications continued on next page ⇒   61-86-03-13   Page 6   Specifications – General, Continued   Physical   Model #   Torque   lb-ft (N_M)   Output   Shaft Size   Shaft Key   Size   Output   Shaft   Length   Maximum   Overhang   Load   Handwheel   Diameter   Approx.   Maximum   Weight   11284S   11285S   11286S   11288S   11289S   11287S   425   (576)   2"   1/2"   (13 mm)   5"   3700 lb.   (1678 kg)   18"   (457 mm)   300 lb.   (136 kg)   (51 mm)   (127 mm)   840   (1139)   2"   1/2"   (13 mm)   5"   3700 lb.   (1678 kg)   18"   (457 mm)   300 lb.   (136 kg)   (51 mm)   (127 mm)   1500   (2033)   2"   1/2"   (13 mm)   5"   3700 lb.   (1678 kg)   18"   (457 mm)   300 lb.   (136 kg)   (51 mm)   (127 mm)   2500   (3389)   2-1/2"   (64 mm)   5/8"   (16 mm)   6"   7500 lb.   (3402 kg)   18"   (457 mm)   550 lb.   (251 kg)   (152 mm)   4000   (5423)   2-1/2"   (64 mm)   5/8"   (16 mm)   6"   7500 lb.   (3402 kg)   18"   (457 mm)   600 lb.   (272 kg)   (152 mm)   5500   2-1/2"   5/8"   6"   7500 lb.   18"   600 lb.   (7457)   (64 mm)   (16 mm)   (152 mm)   (3402 kg)   (457 mm)   (272 kg)   Electrical   115/220 Vac, single phase 50/60 Hz up to 1500 lb-ft   208/200 – 240/380 – 480/575 Vac, three phase 50/60 Hz   Inverter rated, continuous duty, C face mounting   Mains Supply   Motor   Motor Current   Motor Size   Full Load Amps (FLA)   (Horsepower)   @ 230 Vac   @ 460 Vac   ½ ¾ 1 1 ½   2 1.6   2.2   2.6   4.4   5.6   7.8   0.8   1.1   1.3   2.2   2.8   3.9   3 Stays in place   Allows local manual and automatic operation of the actuator   Loss of Power   Local Auto - Manual   Switch   Standard - Two SPDT end-of-travel limits rated 10 A at 125 Vac, 5 A at 250 Vac.   Optional – Up to 2 additional SPDT switches (or 4 relay outputs, programmable)   Limit Switches   Auxiliary   Switches/Relays   Category II: Energy-consuming equipment supplied from the fixed installation. Local level   appliances, and industrial control equipment. (EN 61010-1)   Installation Category   (Overvoltage Category)   Pollution degree 2: Normally non-conductive pollution with occasional conductivity caused by   condensation. (ref. IEC 664-1)   Pollution Degree   61-86-03-13   Page 7   Specifications – Actuator   Electrical   Input Signals   Analog: 0/4 to 20 mA (With supplied 250 ohm shunt resistor for current range)   0/1 to 5 Vdc   0 to 10 Vdc   Digital: Remote Setpoint via Modbus RTU (RS485)   Input Impedance   Input   Input Impedance   250 ohms   0/4 to 20 mA   0/1 to 5 Vdc   10 K ohms   Provides characterization of the input signal.   Selections are: Linear, Square Root or Custom.   Input Characterization   0.2 % to 5 % of 90° span, proportional to deadband   Less than 0.4 % of full scale   Sensitivity   Hysteresis   0.2 % to 5 % of 90° span, adjustable. Shipped at 0.5%   0.2 % of 90° span   Deadband   Repeatability   Voltage/ Supply Stability   0.25 % of span with +10/-15 % voltage change   Temperature Coefficient   Less than ± 0.030 % of span per degree C for 0 °C to 50 °C   Less than ± 0.05 % of span per degree C for -30 °C to 65 °C   90% of span   Zero Suppression   Input Filters   Selectable spike and low pass filters   CW/CCW open collectors (opto-isolators) for use as discrete control inputs to the inverter   for motor operation.   Solid State Motor Control   If input signal exceeds configured input range. Selectable and adjustable.   0 to 20 mA, 4 to 20 mA   Failsafe operation   Feedback signals/Output   0 to 5 Vdc, 1 to 5 Vdc with 250 ohm resistor; (0 to 16 Vdc with 800 ohm resistor)   Provides output voltage ratiometric to shaft position and potentiometric to supply voltage   (1 to 20 Vdc) without a slidewire. Emulates a 100 ohm to 1000 ohm slidewire. 10 mA   output maximum.   Slidewire Emulation   Input signal, output signal and power are isolated from each other.   Current Out — 0 to 1000 ohms   Isolation   Load Requirement (4-20)   Programmable Functions   Selectable and configurable operating parameters:   • • • • • Input range   • • Deadband   • • • Relay closure   action   Input filtering   Failsafe on loss of   input signal   Communication   parameters   Input characterization   Security   • • Failsafe on loss of   position sensor   Split range   operation   Digital Input action   Direction of rotation   • • Output range   Alarms   61-86-03-13   Page 8   Pipe Linkage Kit   Pipe linkage kits are available from Honeywell and can be used for linkage lengths from 24 to 240 inches (61 to 610 cm). The   kits include the mechanical pipe couplings, load rod end (left-hand thread), connecting rods and locking nuts. See Figure 4.   The actuator rod end (right-hand thread), nut and bolt are supplied with the actuator. The customer must supply a piece of   schedule 40 pipe 2 ½” * (both ends with right-hand NP threads) and a nut and bolt to connect the rod end to the load. Pipe   linkage kits can be ordered with the Actuator using Table VIII of the Model Selection Guide.   Linkage Minimum = 24in. (61 cm)   Linkage Maximum = 240in. (610 cm)   + + Pipe Length *   This rod end   supplied on Actuator   with crank arm   *Pipe length = Overall linkage length minus (-) 20 inches (51 cm).   Figure 4 Pipe Linkage Kit   Actuator Crank Arm   The 11280S Series Actuator comes standard with an 8” to   14” adjustable radius crank arm. The crank arm uses a   standard right-hand thread 1” rod end to compliment the   pipe linkage kit.   The crank arm for the 11284S, 11285S and 11286S has a   2” shaft hole, while the crank arm from the 11287S, 11288S   and 11289S has a 2 ½” shaft hole.   Recommended Bolt Torque   The table below lists the type of bolts to be used and the   recommended torque for each bolt.   Bolt Type   Torque   Clamp bolts   220 lb.-ft   220 lb.-ft   Rod End Bolt   Figure 5 11280S Crank Arm   Jam nuts   100 lb.-ft   61-86-03-13   Page 9   External Transformers   120 Vac (Single Phase)   For customer applications requiring 120/240 Vac single phase operation, a step-up transformer is mounted in a separate   enclosure (Model Selection Guide Table I, option 1). Figure 6 shows the installation for the transformer enclosure.   575 Vac (3 Phase)   For customer applications requiring 575/460 Vac 3 phase operation, a step-down transformer is mounted in a separate   enclosure (Model Selection Guide Table I, option 6). Figure 6 shows the installation for the transformer enclosure.   14.0   (355.6 mm)   Ground   Stud   16.0   (406.4 mm)   120/240 Vac   Single Phase   Transformer   575/460 Vac   Three Phase   Transformer   10.0   (254 mm)   Figure 6 Installation Drawing for External Transformer Enclosure   61-86-03-13   Page 10   Model Selection Guide   Reference 62-86-16-19   Instructions   Select the desired key number. The arrow to the right marks the selection available.   Make the desired selections from Tables I thru VIII using the column below the arrow.   A dot ( ) denotes unrestricted availability.   Key Number   _ _ _ _ _ _ _   I _ II   _ III   _ _   IV   _ _ _   V _ _ _   VI   _ VII   _ VIII   _ _ _ _ _ _   IX   _ _   - - - - - - - - - KEY NUMBER - Electronics   Output Torque   Selection   Availability   (lb. - ft.) (N - M)   425   850   1500 (2025)   2500 (3400)   4000 (5425)   5500 (7450)   (575)   (1150)   (Note 1)   (Note 1)   011284S   011285S   011286S   011288S   011289S   011287S   TABLE I - POWER SUPPLY   Single Phase   120 Vac, 50/ 60 Hz   240 Vac, 60 Hz / 200 Vac, 50 Hz   200 - 240 Vac, 60 Hz   380 - 480 Vac, 50-/60 Hz   575 Vac, 60 Hz   1 2 4 5 6 a a Three Phase   TABLE II - STROKE SPEED   Stroke Speed @ 60 Hz 10 sec/90 degrees   30 sec/90 degrees   1 2 3 60 sec/90 degrees   TABLE III - MOTOR ORIENTATION (See specification 61-86-03-13 for diagrams)   Motor   Right-hand floor configuration, H.W. Shaft Horizontal   Left-hand floor configuration, H.W. Shaft Horizontal   01   03   Orientation   TABLE IV - ANALOG INPUT/OUTPUT SIGNALS   Input   Output   4-20 mA, 0-20mA (1-5 Vdc, 0-5 Vdc, 1-10 Vdc, 0-10Vdc)   0 _ _   _ 00   _ 20   _ 40   No Analog Position Output   4-20 mA, 0-20mA (1-5 Vdc, 0-5 Vdc, 1-10 Vdc, 0-10Vdc)   Slidewire Emulation   (Note 2)   61-86-03-13   Page 11   Model Selection Guide, continued   01128_ _   4S   5S   6S   8S   TABLE V - SWITCH AND RELAY OUTPUTS (2 mech end-of-travel limits standard)   Selection   00 _   9S 7S   Auxiliary Switches   and   None   2 Aux. SPDT Switches   20 _   2 Aux. + 2 Programmable Relay Outputs   2 Programmable Relay Outputs   4 Programmable Relay Outputs   22 _   02 _   04 _   Auto/Manual Switch None   One Auto/Manual Switch with Out-of-Auto Contact   _ _0   _ _1   TABLE VI - CONFIGURATION INTERFACE   Remote   Local   None   0 1 Integrally mounted local display/keypad interface   TABLE VII - COMMUNICATIONS/PROTOCOL   Modbus RTU RS485   RS-485 Modbus compliant - standard with EEU   Future   0 1 Additional Communications   TABLE VIII - OPTIONS   Crank Arm   Adjustable 8" to 14" Radii - Standard   None   None   0_ _ _ _ _   1_ _ _ _ _   _0_ _ _ _   _1_ _ _ _   _ _0_ _ _   _ _ _0_ _   _ _ _ _0_   _ _ _ _1_   _ _ _ _2_   _ _ _ _ _0   Linkage Kit   Up to 20 ft. length - customer supplies schedule 40 pipe   Future Option   Future Option   Tagging   None   None   None   Linen   Stainless Steel   None   (Note 3)   (Note 3)   Future Option   TABLE IX - FACTORY OPTIONS   Motor Orientation   None   00   RESTRICTIONS   Restriction   Available Only With   Selection   Not Available With   Selection   11287S, 11288S, 11289S   Letter   a Table   Table   I 11284S, 11285S, 11286S   I Note 1:   Note 2:   Note 3:   Requires (2) adapters PN 51204694-501 for retrofit of existing Leeds & Northrup 011284 and 011285 actuators.   Slidewire emulation is a solid state circuit providing a ratiometric voltage output proportional to shaft position.   Customer must supply tagging information: Up to 3 lines (22 characters for each line)   61-86-03-13   Page 12   Figure 7 Mounting and Outline Dimensions for 11284S, 11285S, 11286S, 11288S, and 11289S   Weather-Proofed Motor Actuators -   Right Hand Floor Mounting, Handwheel Shaft Horizontal (D-MTG-616-200)   61-86-03-13   Page 13   Figure 8 Mounting and Outline Dimensions for 11284S, 11285S, 11286S, 11288S, and 11289S   Weather-Proofed Motor Actuators -   Left Hand Floor Mounting, Handwheel Shaft Horizontal (D-MTG-616-210)   61-86-03-13   Page 14   Warranty/Remedy   Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship.   Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during   the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The   foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including   those of merchantability and fitness for a particular purpose. Specifications may change without   notice. The information we supply is believed to be accurate and reliable as of this printing. However, we   assume no responsibility for its use. © Honeywell 2004.   While we provide application assistance personally, through our literature and the Honeywell web site, it is   up to the customer to determine the suitability of the product in the application.   Distributor :   Tlf: 67150 250 Faks: 67 150 251   Mail: [email protected]   Sensing and Control   Honeywell   11 West Spring Street   Freeport, IL 61032   62-86-03-13 9/01 Printed in USA   |