Haier 0010557172 User Manual

FLOOR UNIT  
OPERATION MANUAL  
HFU-09HA03(B)/R1  
HFU-12HA03(B)/R1  
HFU-09H03/R2(DB)  
HFU-12H03/R2(DB)  
HFU-18H03/R2(DB)  
Please read this operation manual before using the air conditioner.  
No.0010557172  
Cautions  
Do not obstruct or cover the ventilation  
grille of the air conditoner.Do not put fingers  
or any other things into the inlet/outlet and  
swing louver.  
7. The appliance is not intended for use  
by young children or infirm persons  
without supervision.  
8.Young children should be supervised  
to ensure that they do not play with  
the appliance.  
Do not allow children to play with the air  
conditioner.In no case should children be  
allowed to sit on the outdoor unit.  
9. A breaker should be incorporated into  
fixed wiring. The breaker should be  
all-pole switch and the distance between  
its two contacts should be not less than  
3mm.  
Specifications  
The refrigerating circuit is leak-proof.  
The machine is adaptive in following  
situation  
10.Please employ the proper power plug,  
which fit into the power supply cord.  
1.Applicable ambient temperature range:  
11 .The power plug and connecting cable  
must have acquired the local attestation.  
Maximum:D.B/W.B  
Minimum:D.B/W.B  
32oC/23oC  
18oC/14oC  
Indoor  
12.In order to protect the units,please turn  
off the A/C first, and at least 30 seconds  
later, cutting off the power.  
Cooling  
Heating  
Maximum:D.B/W.B 43oC/26oC  
Outdoor  
Indoor  
18oC  
Maximum:D.B  
Maximum:D.B  
Maximum:D.B  
27oC  
15oC  
Maximum:D.B/W.B  
Minimum:D.B/W.B  
24oC/18oC  
-15oC  
Outdoor  
2. If the power supply cord is damaged, it  
must be replaced by the manufacturer  
or its service agent or a similar qualified  
person.  
3. If the fuse of indoor unit on PC board is  
broken,please change it with the type of  
T. 3.15A/ 250V. If the fuse of outdoor unit  
is broken, change it with the type of  
T.25A/250V.  
4. The wiring method should be in line with  
the local wiring standard.  
5. After installation, the power plug should  
be easily reached.  
6. The waste battery should be disposed  
properly.  
2
Cautions  
Safety Instruction  
Please read the following Safety Instructions carefully prior to use  
The instructions are classified into two levels, WARNING and CAUTION according to  
the seriousness of possible risks and damages as follows. Compliance to the  
instructions are strictly required for safety use.  
Installation  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
Installation in a inadequate place may cause accidents. Do not install in the following place.  
securely  
CAUTION  
Connect the earth Do not install in the Do not get the unit Check proper  
cable.  
place where there is exposed to vapor  
installation of the  
drainage  
any possibility of  
inflammable gas  
leakage around the  
unit.  
or oil steam.  
STRICT  
ENFORCEMENT  
earthing  
PROHIBITION  
PROHIBITION  
Grounding wire should not be connected  
to that of gas pipeline, water pipeline,  
lighting arrester or telephone.  
Use fuse with specified capacity.  
Replacement with steel or copper  
wires are absolutely prohibited.  
FUSE  
COPPERWIRE  
STEEL WIRE  
3
Cautions  
WARNING  
When abnormality such as burnt-small found,  
immediately stop the operation button and  
contact sales shop.  
Use an exclusive power source with a  
circuit breaker  
STRICT  
ENFORCEMENT  
OFF  
Connect power supply cord  
to the outlet completely  
After installed, the unit shall be  
tested for electric leakage.  
Do not use power supply cord  
extended or connected in halfway  
STRICT  
ENFORCEMENT  
STRICT  
ENFORCEMENT  
PROHIBITION  
Do not insert objects into the air  
inlet or outlet.  
Take care not to damage  
the power supply cord.  
Do not use power supply cord  
in a bundle.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not channel the air flow directly  
at people, especially at infants or  
the aged.  
Do not start or stop the  
operation by disconnecting  
the power supply cord and so on.  
Do not try to repair or reconstruct  
by yourself.  
PROHIBITION  
PROHIBITION  
CAUTION  
Take fresh air occasionally especially  
when gas appliance is running at the  
same time.  
Do not operate the switch with  
wet hand.  
Do not use for the purpose of storage of  
food, art work, precise equipment,  
breeding, or cultivation.  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
Do not pour water onto the unit  
for cleaning  
Do not install the unit near a fireplace  
or other heating apparatus.  
Check good condition of the  
installation stand  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not place animals or plants in  
the direct path of the air flow  
Do not place flower vase or water  
containers on the top of the unit.  
Do not place any objects on or  
climb on the unit.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
4
Parts and Functions  
Indoor unit  
1.OUTLET  
2.CONTROL PANEL  
3.INLET  
4.FILTER (inside)  
5.OUTLET  
Outdoor unit  
HFU-09HA03(B)/R1  
HFU-12HA03(B)/R1  
HFU-09H03/R2(DB)  
HFU-12H03/R2(DB)  
HFU-18H03/R2(DB)  
OUTLET  
INLET  
CONNECTING PIPING AND ELECTRICAL WIRING  
DRAIN HOSE  
5
Parts and Functions  
CAUTION  
Before opening the front grille, be sure  
to stop the operation and turn the  
breaker OFF.  
Receiver  
Do not touch the metal parts on the  
inside of the indoor unit, as it may result  
in injury.  
Signals are received from the remote  
controller here.  
Upon receiving a signal, there is a receiving  
sound.  
Air outlet selection switch  
This setting blows air from upper outlet only.  
This setting automatically decides a blow  
pattern depending on mode and conditions.  
This setting is  
recommended.  
The unit is shipped from the  
factory with this setting.  
ON/OFF button  
Push once to start operation,  
push once again to stop it.  
Operation is set to AUTO, air  
flow is set to AUTO FAN.  
Use when remote controller is  
not available.  
Air outlet  
selection  
Indoor temperature sensor  
Senses the air temperature around the unit.  
Operating  
mode  
Situation  
Blowing pattern  
Air flow selection  
Make air flow selection according to what suits you.  
When the room has  
become fully cool, or  
when one hour has  
passed since turning  
So that air does not come  
into direct contact with  
people, air is blown upper air  
outlet, room temperature is  
When setting the air flow selection  
switch to  
Air conditioner automatically decides the  
appropriate blowing pattern depending on the  
operating mode/situation.  
on the air conditioner. equalised  
Cool  
mode  
At start of operation  
or other times when  
the room is not fully  
cooled.  
Air is blown from the upper and  
During Dry mode, so that cold air does not come  
into direct contact with people, air is blown upper  
air outlet.  
lower air outlets for high speed  
cooling during Cool mode, and  
for filling the room with warm  
air during Heat mode.  
At times other than  
below. (Normal  
time.)  
When setting the air outlet selection  
switch to  
Regardless of the operating mode or situation, air  
blows from the upper air outlet.  
Use this switch when you do not want air coming  
out of the lower air outlet. (While sleeping etc..)  
Heat  
mode  
At start or when air  
temperature is low.  
So that air does not come into  
direct contact with people. Air  
is blown upper air outlet.  
6
Parts and Functions  
4. MODE  
Used to select AUTO, COOL, DRY, FAN and  
Remote Controller  
HEAT operation.  
5. ON/OFF  
Used for unit start and stop.  
6. SWING  
Used to adjust the up/down air flow direction.  
7. TEMP.  
Used to select your desired temperature.  
8. TIMER ON display  
9. SLEEP display  
10. FAN SPEED display  
Remote controller:  
LOW  
MED  
HI  
AUTO  
11. SWING UP/DOWN display  
12. MODE display  
Operation  
mode  
Remote  
controller  
AUTO  
COOL  
DRY  
FAN  
HEAT  
13. SIGNAL SENDING display  
14. TEMP. display  
Remote controller: to display the TEMP. setting.  
15. CLOCK display  
16. TIMER OFF display  
17. FAN  
Used to select fan speed: LO,MED,HI,AUTO  
18. SET  
1.TIMER  
Used to select TIMER ON,  
TIMER OFF, TIMER ON-OFF  
2.HOUR  
Used to confirm timer and clock settings.  
Used to set clock and timer setting.  
19. SLEEP  
Used to select sleep mode.  
3.CLOCK  
20. RESET  
Used to set correct time.  
When the remote controller appears abnormal,  
use a sharp pointed item to press this button  
to reset the remote controller to normal condition.  
Note:  
1. The following functions and related  
displays are not available for all models:  
Display of humidifying and atmosphere  
humidity.  
21. LOCK  
Used to lock buttons and LCD display. If  
pressed, the other buttons will be disabled and  
the lock condition display appears.  
Press it once again, lock will be canceled and  
lock condition display disappears.  
22. LOCK display  
2. There is health display with the remote  
controller in this type, but without health  
function.  
23. POWER/SOFT  
7
Parts and Functions  
Clock Set  
When unit is started for the first time and after replacing batteries in remote  
controller, clock should be adjusted as follows:  
1. Press CLOCK button,"AM" or "PM" flashes.  
2. Press or  
to set correct time. Each press will increase or decrease 1  
min. If the button is kept depressed, time will change quickly.  
3. After time setting is confirmed, press SET, "AM" or "PM" stop  
flashing,  
while clock starts working.  
Remote controller's operation  
When in use, put the signal transmission head directly to the receiver hole on the indoor unit.  
The distance between the signal transmission head and the receiver hole should be within 7 m  
without any obstacle as well.  
Don't throw or knock the remoter controller.  
When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless  
telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals,  
so the distance to the indoor unit should be shorter.  
Loading of the battery  
Load the batteries as illustrated right  
2 R-03 (7#) batteries  
Remove the battery cover:  
Slightly press" "area and push down the cover  
as illustrated.  
Load the battery:  
Be sure that the loading is in line with the "+" / "-".  
request as illustrated on the bottom of the case.  
Put on the cover again.  
Confirmation indicator:  
After pressing power ON/OFF, if no display, reload the batteries.  
Note:  
Full display or unclear display during operation indicates the batteries have been used up.  
Please change batteries.  
Used two new same-typed batteries when loading.  
If the remote controller can't run normally during operation, please remove the batteries and  
reload several minutes later.  
Hint:  
Remove the batteries in case unit won't be in usage for a long period. If there are any display after  
taking-out, just need to press reset key.  
8
Operation  
1. Unit start  
Auto Operation  
Press ON/OFF on the indoor unit, or press ON/OFFon  
the remote controller, unit starts.  
Previous operation status appears on LCD display (no  
timer and sleep), and set the operation mode.  
2.Select operation mode  
Remote controller  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select Auto operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
4
5
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed wind speed  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
About AUTO mode  
In AUTO run mode, the air conditioner will  
automatically select cooling or heating  
operation mode according to room temperature.  
9
Operation  
Cool Operation  
1. Unit start  
Remote controller  
Press ON/OFF on the indoor unit, or press ON/OFFon  
the remote controller, unit starts.  
Previous operation status appears on LCD display (no  
timer and sleep).  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select Cool operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed wind speed  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
10  
Operation  
DRY Operation  
1. Unit start  
Press ON/OFF on the indoor unit, or press ON/OFFon  
the remote controller, unit starts.  
Previous operation status appears on LCD display (no  
timer and sleep).  
Remote controller  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select DRY operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed fan speed.  
In DRY mode, when room temperature becomes  
lower than temp.setting+2oC,unit will run intermittently  
at LOW speed regardless of FAN setting.  
5.Unit stop  
COOL operation starts when room  
temp.is higher than temp.setting.  
Ultra-low air flow  
Press ON/OFF button, the unit stops.  
Temp.setting+2oC  
Temp.setting  
On reaching temp.setting +2oC  
unit will run in mild DRY mode.  
11  
Operation  
FAN Operation  
1. Unit start  
Press ON/OFF on the indoor unit, or press ON/OFFon  
the remote controller, unit starts.  
Remote controller  
Previous operation status appears on LCD display (no  
timer and sleep).  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select FAN operation  
3.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
HI  
MED  
4.Unit stop  
Press ON/OFF button, the unit stops.  
About FAN operation  
In FAN operation mode, the unit will not operate in  
COOL or HEAT mode but only in FAN mode. AUTO is  
not available in FAN mode. And temp. setting is disabled.  
In FAN mode, SLEEP operation is not available.  
12  
Operation  
HEAT Operation  
1. Unit start  
Press ON/OFF on the indoor unit, or press ON/OFFon  
the remote controller, unit starts.  
Previous operation status appears on LCD display (no  
timer and sleep).  
Remote controller  
2.Select operation mode  
Press MODE button. For each press, operation mode  
changes as follows:  
Remote controller:  
AUTO  
COOL  
DRY  
FAN  
HEAT  
Then Select HEAT operation  
3.Select temp.setting  
Press TEMP. button  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will decrease  
rapidly  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed changes as  
follows:  
Remote controller:  
LOW  
AUTO  
HI  
MED  
Air conditioner is running under displayed wind speed  
IN HEAT mode, warm air will blow out after a short period  
of the time due to cold-draft prevention function.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
Regarding the ambient  
temperature display during  
the heating operation  
In defrosting,the indoor temperature  
value displayed may be reduced due  
to the dropping of cooling air of the  
evaporator of indoor unit under cooling  
mode. It is normal phenomenon.  
5.Unit stop  
Press ON/OFF button, the unit stops.  
13  
Operation  
Adjusting the Air Flow Direction  
Notes on flap angles  
You can adjust the air flow direction to increase  
your comfort  
When SWING is selected, the flap swinging range depends  
on the operation mode.(See the figure.)  
COOL/DRY  
HEAT  
Adjusting the flap  
NOTE  
Unless [SWING] is selected, you should set the flap at a  
near-horizontal angle in HEAT mode and at a upward  
position in COOL or DRY mode to obtain the best  
performance.  
CAUTION  
Do not try to adjust the flap by hand.  
When adjusting by hand, the mechanism may not  
operate properly or condensation may drip from air  
outlets  
ATTENTION  
When adjusting the flap by hand, turn off the unit,  
and use the remote controller to restart the unit.  
Adjusting the louver  
Hold the knob and move the louver.  
(You will find a knob on the left-side and the right-side blades  
ATTENTION  
Be careful when adjusting the louver. Inside the air  
outlet, a fan is rotating at a high speed.  
14  
Operation  
SLEEP Operation  
Before going to bed , you can simply press the  
SLEEP button and unit will operation in SLEEP  
mode and bring you a sound sleep.  
2. In HEAT mode  
3 hours after SLEEP mode starts, temperature  
will become 1oC lower than temperature setting.  
After another 3 hours temperature decrease by  
1oC further. The unit will run for further 2 hours  
then stops. Temperature is lower than  
temperature setting so that room temperature  
won't be too high for your sleep.  
Use of SLEEP function  
After the unit starts, set the operation status,  
then press SLEEP button before which the  
clock must be adjusted and time being set.  
Operation Mode  
1. In COOL,DRY mode  
Temperature setting  
3 hr  
Unit stop  
3 hours after SLEEP mode starts, temperature  
will become 1oC higher than temperature setting.  
After another 3 hours temperature rises by 1oC  
further. The unit will run for further 2 hours then  
stops. Temperature is higher than temperature  
setting so that room temperature won't be too  
low for your sleep.  
Decreases 1o  
C
3 hr  
Decreases 1o  
C
Approx. 2 hrs  
SLEEP  
operation starts  
SLEEP  
operation stops  
Remote controller  
In HEAT mode  
3. In AUTO mode  
The unit operates in corresponding sleep  
SLEEP mode adapted to the automatically  
selected operation mode.  
4. In FAN mode  
It has timing off function.  
5. The sleep time can be adjusted within  
the range of 1-8 hours.  
Push the SLEEP button. The remote  
controller will display " ", and display the  
timing off and detail off time in the timing  
off setting area.  
Push the time adjusting button to adjust the  
detail sleep time.  
6. If the sleep time in cooling, dehumidifying  
and heating run is less than 8 hours  
Within the set sleep time, the conditioner will  
run as per the procedure described in 1 and  
2. It will be switched off automatically when  
the sleep time is expired.  
SLEEP operation starts  
SLEEP operation stops  
Approx. 2 hrs  
Rises 1o  
C
3 hr  
Rises 1o  
C
3 hr  
Temperature setting  
Unit stop  
In COOL,DRY mode  
15  
Operation  
Timer On/Off Operation  
Set clock correctly before starting TIMER operation.  
1. After unit starts, select your desired operation mode.  
Operation mode will be displayed on LCD  
2. Timer mode selection  
Remote controller  
Press TMIER button to change TIMER mode. Every time'  
the button pressed, display changes as follows:  
Remote controller:  
BLANK  
TIMER ON TIMER OFF  
TIMER ON-OFF  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF). "  
"or "  
"will flash.  
3.Time setting  
Press HOUR  
button.  
Every time the button is pressed, time setting  
increases 1 min, if kept depressed, it will increase  
rapidly.  
Every time the button is pressed, time setting  
decreases 1 min, if kept depressed, it will decrease  
rapidly.  
It can be adjusted within 24 hours.  
4.Confirming your setting  
After setting correct time, press SET button to confirm  
"
"or"  
"on the remote controller stops flashing.  
Time displayed: Unit starts or stops at x hour x min.  
(TIMER ON or TIMER OFF).  
5.Cancel TIMER mode  
Just press TIMER button several times until TIMER  
mode disappears.  
Hints:  
After replacing batteries or a power failure happens, time setting should be reset.  
Remote controller possesses memory function, when use TIMER mode next time,just  
press SET button after mode selecting if time setting is the same as previous one.  
16  
Operation  
TIMER On-Off Operation  
Set clock correctly before starting TIMER operation.  
1. After unit starts, select your desired operation mode  
Operation mode will be displayed on LCD.  
2.Timer mode selection  
Remote Controller  
Press TIMER button to change TIMER mode. Every time  
the button is pressed, display changes as follows:  
Remote controller:  
BLANK  
TIMER ON TIMER OFF  
TIMER ON-OFF  
Then select your desired TIMER mode (TIMER ON - OFF).  
"will flash.  
"
3.Time setting  
Press HOUR  
button.  
Every time the button is pressed, time setting  
increases 1 min, if kept depressed, it will increase rapidly.  
Every time the button is pressed, time setting  
decreases 1 min, if kept depressed, it will decrease rapidlly.  
It can be adjusted within 24 hours.  
4.Timer confirming for TIMER ON  
After setting correct time, press TIMER button to confirm  
"
"
" on the remote controller stops flashing.  
" starts flashing.  
Time displayed: Unit starts or stops at x hour x min.  
5.Time setting for TIMER OFF  
Just press HOUR button ,follow the same procedure in  
"Time setting for TIMER ON"  
6.Time confirming for TIMER OFF  
After time setting,press SET button to confirm.  
"
" on the remote controller stops blinking.  
Time displayed:Unit stops at x hour x min.  
To cancel TIMER mode  
Just press TIMER button several times until TIMER  
mode disappears.  
According to the Time setting sequence of TIMER ON  
or TIMER OFF, either Start-Stop or Stop-Start can be  
achieved.  
17  
Operation  
POWER/SOFT Operation  
POWER Operation  
When you need rapid heating or cooling, you can use this funciton.  
Selecting of POWER operation  
Press POWER/SOFT button. Every time the button is pressed,display  
changes as follows:  
BLANK  
SOFT  
POWER  
Stop the display at  
In POWER operation status:  
In HEAT or COOL mode, fan speed automatically runs in HI mode  
for 15 min then returns to original status setting.  
To cancel POWER operation  
Press POWER/SOFT button twice ,POWER/SOFT disappears.  
SOFT Operation  
You can use this function when silence is needed for rest or reading.  
Selecting of SOFT operation  
Press POWER/SOFT button. Every time the button is pressed,display  
changes as follows:  
BLANK  
SOFT  
POWER  
Stop the display at  
In SOFT operation mode, fan speed automatically takes"LOW"  
To cancel SOFT operation  
Press POWER/SOFT button twice ,POWER/SOFT disappears.  
Hints:  
During POWER operation, in rapid HEAT or COOL mode, the room  
will show inhomogeneous temperature distribution.  
Long period SOFT operation will cause effect of not too cool  
or not too warm.  
18  
Operation  
EMERGENCY OPERATION AND TEST OPERATION  
EMERGENCY OPERATION  
Carry out this operation only when the remote  
controller is defective or lost.  
POWER  
TIMER  
RUN  
Unit start  
When the emergency operation switch is  
pressed, a sound you can hear, which  
means the start of this operation.  
ON/OFF  
Follow the requirements below.  
EMERGENCY SWITCH  
Room  
temperature  
Air flow  
speed  
Designated  
temperature  
Timer  
mode  
Operation  
mode  
Anion  
>23oC  
26oC  
23oC  
None AUTO  
None AUTO  
COOL None  
HEAT None  
*23oC  
Unit stop (to cancel emergency operation)  
Press the emergency switch and hear a sound, the unit stops.  
TEST OPERATION  
Use this switch in the test operation when the room  
temperature is less 16oC, do not it in the normal  
operation.  
TIMER  
Unit start  
POWER  
RUN  
Continue to press the test operation switch  
for more than 5 seconds. After you hear the  
"BI" sound twice, release your finger from  
the switch, the test operation starts and the  
air conditioner starts with the air flow speed  
setting "Hi".  
ON/OFF  
TEST SWITCH  
Unit stop(to cancel test operation)  
Push the test run switch or operate with remote controller to cancel the test run.  
If you use the remote controller to cancel the test run, the conditioner will then run as  
per the working mode displayed on the remote controller.  
19  
Operation hints  
Remote monitoring  
The control board of the indoor unit reserves the communication port for remote control. If  
you install the peripheral equipment according to the manual of the matching remote control  
detector, it can realize the computer management or remote monitoring of the conditioner.  
Please refer to the manual of the " Conditioner remote control detector" for the details  
Power failure resume(please set and apply as necessary)  
With setting of power failure resume, if sudden power failure occurs, the unit will resume  
original operation when power is supplied again.  
Setting method  
With ON of remote controller (except TIMER and FAN),repeatedly press SLEEP button 10  
times in 5 seconds, after 4 Beep from the buzzer, the unit comes into power failure resume  
mode.  
To cancel:  
press SLEEP button continuously 10 times in 5 seconds, the buzzer sounds Beep twice and  
power failure resume function is canceled.  
Note:  
When sudden power failure happens during unit operation in power failure resume mode,if  
the air conditioner is not desired for use in a long period, please shut off the power supply  
in case that the unit automatially resume operation when power is re-supplied, or press  
ON/OFF to turn off the unit when power resumes.  
20  
Maintenance  
Cleaning of the unit  
Do not clean with hot  
water or solvent  
Turn off the power switch  
Do not touch with wet hand  
Take off the air inlet grill  
First switch off the power supply, take off the  
screw cap, loosen the screw with cross screwdriver.  
Clean the filter  
Use water or vacuum cleaner to remove  
dust. If it is too dirt, clean with detergent or  
neutral soap water.  
Rinsing with fresh water, dry the filter and  
re-assemble.  
Caution:  
Do not wash filter in hot water above 40oC,  
which will damage the filter.  
Do carefully wipe the filter.  
Clean the indoor(outdoor) unit  
Clean with warm cloth or neutral detergent,  
then wipe away moisture with dry cloth. Do  
not use too hot water(above 40oC), which will  
cause discoloration or deformation. Do not  
use pesticide or other chemical detergents.  
21  
Maintenance  
Maintenance at the end of application season  
On a fine day, unit shall be started and operate in  
FAN mode for about half a day unit the inside of  
the unit becomes thoroughly dry.  
Turn off the unit operation switch and power on/off.  
Otherwise, there will be some electricity consumption  
even the unit is in stop status.  
Clean the filter and indoor, outdoor unit, cover  
the units well.  
Maintenance before beginning of application season  
Check there are no obstacles in the air inlet and  
outlet to avoid impairing of working efficiency.  
Please do attach the air filter to ensure the  
electrostatic filters not soiled. Otherwise,dirt  
will come into and damage the unit or bring  
failures.  
22  
Trouble shooting  
Before asking for service, check the following first.  
Phenomenon  
Cause or check points  
The system does not restart  
immediately.  
When unit is stopped, it won't restart  
immediately until 3 minutes have elapsed  
to protect the system.  
When the electric plug is pulled out and  
reinserted, the protection circuit will work  
for 3 minutes to protect the air conditioner.  
During unit operation or at stop, a swishing  
or gurgling noise may be heard. At first 2-3  
minutes after unit start, this noise is more  
noticeable. (This noise is generated by  
refrigerant flowing in the system.)  
During unit operation, a cracking noise may  
be heard. This noise is generated by the  
casing expanding or shrinking because of  
temperature changes.  
Noise is heard:  
Normal  
Performance  
inspection  
Should there be a big noise from air flow in  
unit operation, air filter may be too dirty.  
This is because the system circulates smells  
from the interior air such as the smell of  
furniture, cigarettes.  
Smells are generated.  
Mist or steam are blown out.  
During COOL or DRY operation, indoor unit  
may blow out mist. This is due to the sudden  
cooling of indoor air.  
Is power plug inserted?  
Is there a power failure?  
Is fuse blown out?  
Multiple  
check  
Does not work at all.  
Poor cooling  
Is the air filter dirty? Normally it should be  
cleaned every 15 days.  
Are there any obstacles before inlet and outlet?  
Is temperature set correctly?  
Are there some doors or windows left open?  
Is there any direct sunlight through the  
window during the cooling operation?(Use  
curtain)  
Are there too much heat sources or too many  
people in the room during cooling operation?  
23  
Installation Manual of Room Air Conditioner  
Installation of indoor unit  
selection of installation place  
oerthan10cm  
Place where it is easy to route drainage pipe  
and outdoor piping.  
more than 10 cm  
Place, away from heat source and with less  
direct sunlight.  
more than 10 cm  
Place where cool and warm air could be  
delivered evently to every corner of the room.  
Place near power supply socket.Leave enough  
space around the unit.  
Place, robust not causing vibration, where the  
body can be supported sufficiently.  
To prevent interference, place it at least 1m  
away from other electric machines, such as  
TV set, radio.  
more than 100 cm  
Figure.1  
Figure.2  
Installation  
According to the dimension of the Figure 2 shown  
nail two cement steel nails on the wall keep 2-3mm  
out, then hang the back of the unit on them.  
There must be no gap between the indoor unit and  
wall.  
Remove the front panel,then use two fastening  
screws to fix the unit on the floor. As Figure 3 shown.  
Once refrigerant piping and drain piping connections  
are complete,fill the gap of the through hole with putty.  
Attach the front panel and front grille in their orginal  
positions once all connections are complete.  
Figure.3  
Installation of outdoor unit  
selection of installation place  
more than 10 cm  
Place strong enough to support the unit and will  
not cause vibration and noise.  
Place where discharged wind and noise does not  
cause a nuisance to the neighbors.  
more than 10 cm  
Place where is less affected by rain or direct sunlight  
and is sufficiently ventilated,or to install a shield.  
Place with enough space for smooth air flow.  
more than 60 cm  
Figure.4  
24  
Installation Manual of Room Air Conditioner  
Tool necessary  
No. Shape and description  
QTY  
1.Screw driver  
2.Hacksaw  
3.70mm dia. hole core drill  
4.Spanner(dia.17,27mm)  
5.Spanner(14,17,27mm)  
6.Pipe cutter  
1
1
4
Remote controller  
Drain hose  
Plastic cap  
7.Flaring tool  
1
Drain-elbow  
8.Knife  
9.Nipper  
Self-tapping screw  
4
4
2
10.Gas leakage detector  
or soap water  
Rubber pad  
11.Measuring tape  
12.Reamer  
dry battery #7  
13.Refrigerant oil  
Floor fixing dimensions of the outdoor unit(Unit:mm)  
Standard accessories  
HFU-09H03/R2(DB)  
HFU-12H03/R2(DB)  
HFU-18H03/R2(DB)  
Following parts shall be field  
supplied  
140  
500  
140  
Mark  
A
Part name  
Adhensive tape  
Pipe clip  
HFU-09HA03(B)/R1  
HFU-12HA03(B)/R1  
B
105  
500  
105  
C
Connecting hose  
D
Insulation material  
Drain hose  
E
105  
550  
105  
Fixing of the unit  
1. Position of the wall hole  
Indoor side  
Wall hole  
Outdoor side  
Wall hole should be decided according to installation  
place and piping direction.(refer to installation drawings).  
Thickness  
of wall  
2. Making a wall hole  
Drill a hole of 120x70mm dia. with a little slope towards  
outside.  
(Cross section of wall hole)  
25  
Installation Manual of Room Air Conditioner  
3. Piping connection  
Connecting method  
Apply refrigerant oil at half union and flare nut.  
To bent a pipe, give the roundness as large as possible not to crash the pipe.  
When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to Fig.  
Be careful not to let foreign matters, such as sands enter the pipe.  
Forced fastening without careful  
centering may damage the  
threads and cause a leakage of gas.  
Fastening torque  
18N.m  
Pipe Diameter  
Liquid side 6.35mm(1/4")  
Gas side 9.52mm(3/8")  
Gas side 12.7mm(1/2")  
42N.m  
55N.m  
Piping connection of the indoor unit  
1. Arrangement of piping and drainage pipe  
Remove the cover before working.  
Cut away, with a hammer or a saw, the lid for piping according to piping direction.  
insulation material  
Drain hose  
Copper tube  
Connecting electric cable for  
indoor and outdoor unit  
According to the piping method, connect the piping on indoor unit with union of connection pipe.  
Arrange the piping as per the wall hole and bind drain hose connecting electric cable and piping  
together with polyethylene tape.  
Insert the bound piping connecting electric cable and drain hose through wall hole to connect  
with outdoor unit.  
2. Arrangement drain hose  
Drain hose shall be placed in under place.  
There should be a slope when arrange drain hose. Avoid up and down waves in drain hose.  
If humidity is high, drain pipe(especially in room and indoor unit) must be covered with  
installation material.  
26  
Installation Manual of Room Air Conditioner  
3. Piping connection of the outdoor unit  
Connecting the connecting pipe and inlet and  
outlet liquid pipe according to the piping method  
Purging Method:(For R410A)  
Liquid Side  
6.35mm(1/4")  
Gas Side  
9.52mm(3/8")  
12.7mm(1/2")  
Detach the service port's cap of 3-way valve, the  
valve rod's cap for 2-way valve and 3-way's, connect  
the service port into the projection of charge hose  
(low) for gaugemanifold. Then connect the projection  
of charge hose (center) for gaugemanifold into  
vacuum pump.  
3-way valve  
2-way valve  
Gaugemanifold(for R410A)  
Anti countercurrent joint  
Vacuum pump(for R410A)  
Tube(for R410A)  
Open the handle at low in gaugemanifold, operate  
vacuum pump. If the scale-moves of gause (low)  
Open  
reach vacuum condition in a moment, check  
again.  
Vacuumize for over 15min. And check the level gauge  
which should read -0.1 MPa (-76 cm Hg) at low  
pressure side. After the completion of vacuumizing,  
close the handle 'Lo' in gaugemanifold and stop the  
operation of the vacuum pump.  
Close  
Check the condition of the scale and hold it for 1-2min.  
If the scale-moves back in spite of tightening, make  
flaring work again, the return to the beginning of  
.
Open the valve rod for the 2-way valve to an angle of  
anticlockwise 90 degrees.  
3-way valve  
2-way valve  
Service port  
90ofor 6 sec.  
Open  
90o  
After 6 seconds, close the 2-way valve and make  
the inspection of gas leakage.  
If it does not stop gas leakage, discharge  
whole refrigerants from the service port.  
After flaring work again and vacuumize,  
fill up prescribed refrigerant from the gas  
cylinder  
In case of gas leakage, tighten  
parts of pipe connection. If  
leakage stops, then proceed  
steps.  
No gas leakage?  
Detach the charge hose from the service port, open  
2-way valve and 3-way. Turn the valve rod anticlockwise  
until hitting lightly.  
Liquid Side  
Gas Side  
9.52mm(3/8")  
12.7mm(1/2")  
3-way valve  
2-way valve  
6.35mm(1/4")  
3-way valve  
2-way valve  
To prevent the gas leakage, turn the service port's  
cap, the valve rod's cap for 2-way valve and 3-way's  
a little more than the point where the torque increases  
suddenly.  
HFU-09H03/R2(DB)  
HFU-12H03/R2(DB)  
HFU-18H03/R2(DB)  
3-way valve  
2-way valve  
Valve rod cap  
Valve rod cap  
Service port cap  
After attaching the each caps, check the gas leakage  
around the caps.  
CAUTION:  
1.If the refrigerant of the air conditioner leaks, it is necessary to  
discharge all the refrigerant. Vacuumize first, then charge the liquid  
refrigerant into air conditioner according to the amount marked on  
the name plate.  
2.Please do not let other cooling medium, except specified one (R410A),  
or air enter into the cooling circulation system. Otherwise, there will be  
abnormal high pressure in the system to make it crack and lead to  
personal injuries.  
27  
Installation Manual of Room Air Conditioner  
3. Piping connection of the outdoor unit  
Connecting the connecting pipe and inlet and  
outlet liquid pipe according to the piping method  
Gas Side  
12.7mm(1/2")  
3-way valve  
Purging Method:(For R407C)  
2-way valve  
Liquid Side  
6.35mm(1/4")  
Detach the service port's cap of 3-way valve, the  
valve rod's cap for 2-way valve and 3-way's, connect  
Gaugemanifold  
the service port into the projection of charge hose  
(low) for gaugemanifold. Then connect the projection  
of charge hose (center) for gaugemanifold into  
vacuum pump.  
Vacuum pump  
Open the handle at low in gaugemanifold, operate  
vacuum pump. If the scale-moves of gause (low)  
Open  
reach vacuum condition in a moment, check  
again.  
Vacuumize for over 15min. And check the level gauge  
which should read -0.1 MPa (-76 cm Hg) at low  
pressure side. After the completion of vacuumizing,  
close the handle 'Lo' in gaugemanifold and stop the  
operation of the vacuum pump.  
Close  
Check the condition of the scale and hold it for 1-2min.  
If the scale-moves back in spite of tightening, make  
flaring work again, the return to the beginning of  
.
3-way valve  
2-way valve  
Service port  
90ofor 6 sec.  
Open the valve rod for the 2-way valve to an angle of  
anticlockwise 90 degrees.  
Open  
90o  
After 6 seconds, close the 2-way valve and make  
the inspection of gas leakage.  
If it does not stop gas leakage, discharge  
whole refrigerants from the service port.  
After flaring work again and vacuumize,  
fill up prescribed refrigerant from the gas  
cylinder  
In case of gas leakage, tighten  
parts of pipe connection. If  
leakage stops, then proceed  
steps.  
No gas leakage?  
3-way valve  
2-way valve  
Detach the charge hose from the service port, open  
2-way valve and 3-way. Turn the valve rod anticlockwise  
until hitting lightly.  
To prevent the gas leakage, turn the service port's  
cap, the valve rod's cap for 2-way valve and 3-way's  
a little more than the point where the torque increases  
suddenly.  
3-way valve  
2-way valve  
Service port cap  
Valve rod cap  
Valve rod cap  
After attaching the each caps, check the gas leakage  
around the caps.  
3-way valve  
12.7mm(1/2")  
2-way valve  
6.35mm(1/4")  
CAUTION:  
2-way valve  
6.35mm(1/4")  
3-way valve  
9.52mm(3/8")  
1.If the refrigerant of the air conditioner leaks, it is necessary to  
discharge all the refrigerant. Vacuumize first, then charge the liquid  
refrigerant into air conditioner according to the amount marked on  
the name plate.  
HFU-12HA03(B)/R1  
HFU-09HA03(B)/R1  
28  
Installation Manual of Room Air Conditioner  
Note: When additional refrigerant is necessary, first purge air out of connecting pipe by external gas,  
then drive out the excessive refrigerant by purging method..  
Brand new unit is charged 80g more refrigerant than spec. This is only for first installation to purge air  
in the indoor unit and connecting pipe.  
When piping is longer than 5m, change additional refrigerant specified in this list.  
Pipe length  
5m  
10m  
90  
15m  
180  
Refrigerant charge(g)  
Electric wiring  
Note:  
Electric wiring must be done by qualified person.  
Use copper wire only.  
The parameter of the connecting cable is H05RN-F or H07RN-F  
-mod 09-12: 3G1.5mm2+1x0.75mm2  
-mod 18 : 3G2.5mm2+1x0.75mm2  
Wiring of indoor unit  
Insert the cable from outside the wall hole where piping already exist.  
Pull it out from front.  
Loose terminal screw and insert cable end fully into terminal block, then tighten it  
Pull the cable gently to make sure it is tight.  
Replace cover after wiring.  
Indoor unit  
1(N) 2(L) 3(C)  
N
L
Terminal block  
Wire clip  
White  
Black  
power  
Wire loop  
Yellow/Green  
Red  
Outdoor unit  
Wiring of outdoor unit  
Insert the cable from inside the wall hole where piping already exist.  
Pull it out from front.  
Loose terminal screw and insert cable end fully into terminal block, then tighten it  
Pull the cable gently to make sure it is tight.  
Replace cover after wiring.  
Note:  
When connecting indoor and outdoor wire, check the number on indoor and outdoor terminal  
blocks. Terminals of same number and same color shall be connected by the same wire.  
Incorrect wiring may damage air conditioner's control or cause operation failure.  
29  
Installation Manual of Room Air Conditioner  
Others  
1. Power supply  
Air conditioner must use an exclusive line(over 20A) .  
The type of power supply wire is HF05VV-3G2.5mm2.  
When installation air conditioner in a wet place, try to use a circuit breaker against current  
leakage.  
For installation in other places, use circuit breaker as for as possible.  
2. Piping cutting and flaring  
Be sure to carry out deburring after cutting with a pipe cutter.  
Insert flaring tool to make a flare  
A
For cooling medium R410A  
Flare tool for R410A  
Clutch-type  
Conventional flare tool  
clutch-type(Rigid-type)  
Wing-nut type (Imperial-type)  
0~0.5mm  
1.0~1.5mm  
1.5~2.0mm  
Flare tooling die  
2.Remove burs  
For cooling medium R407C  
1.Cut pipe  
Pipe diameter  
Size A (mm)  
0.8~1.5  
6.35mm(1/4")  
9.52mm(3/8")  
12.7mm(1/2")  
Liquid side  
Gas side  
Gas side  
1.0~1.8  
1.2~2.0  
3.Insert the flare nut  
4.Flare pipe  
Correct  
Incorrect  
Lean Damage of flare Crack  
Partial  
Too outside  
Installation inspection and test run:  
Please operate unit according to this Manual  
Items to be checked during test run. Please made a "  
Are there any gas leakage?  
" in "  
"
How is insulation at piping connection carried out?  
Are electric wires of indoor and outdoor unit firmly inserted into terminal block?  
Is electric wiring of indoor and outdoor securely fixed?  
Is drainage securely carried out?  
Is earth line(grounding) securely connected?  
Is power supply voltage abided by the code?  
Is there any noise?  
Is control display normal?  
Is cooling operation normal?  
Is room temp. regulator normal?  
30  

Brother MFC 990cw User Manual
Carrier 38APS025 065 User Manual
Friedrich Air Conditioner E S12 User Manual
GE General Electric Air Conditioner 6100 User Manual
GE General Electric Air Conditioner agv08 User Manual
Goldstar M5203L User Manual
Goodman Mfg Co LP Air Conditioner SS SSX16 User Manual
Haier Air Conditioner HPU 48CK03 User Manual
HP Hewlett Packard Deskjet 693C User Manual
HP Hewlett Packard M1212NF User Manual