Goodman Mfg GPC14H User Manual

GPC14H  
2- to 5-ton  
Packaged air conditioner  
up to 14 SEER  
cooling caPacity: 24,000 - 57,500 BtU/H  
Product Features  
• Energy-efficient compressor  
with internal relief valve  
• EEM blower motor  
• Quiet horizontal discharge  
• Copper tube/aluminum fin coil  
• Totally enclosed, permanently lubricated  
condenser fan motor  
• Fully charged system  
• 5 kW to 20 kW electric heat kit available  
as a field-installed option  
• AHRI Certified; ETL Listed  
Cabinet Features  
• Heavy-gauge galvanized-steel cabinet with  
attractive Architectural Gray powder-paint finish  
• Fully insulated blower compartment  
with convenient access panels  
• Louvered condenser coil protection  
• One footprint; three heights  
Contents  
Nomenclature......................................................................... 2  
Product Specifications ............................................................ 3  
Airflow Data ............................................................................ 5  
Expanded Cooling Data .......................................................... 6  
Heater Kit Specifications ...................................................... 26  
Dimensions ........................................................................... 27  
Wiring Diagrams ................................................................... 28  
Accessories ............................................................................ 30  
manmfg.com. To receive the 10-Year Parts Limited Warranty, online registration  
must be completed within 60 days of installation. Online registration is not  
required in California or Québec  
.
SS-GPC14H  
7/11  
Supersedes 6/11  
Product SPecificationS  
SPecificationS  
GPC14  
24H41AC  
GPC14  
30H41AA  
GPC14  
30H41AC  
GPC14  
36H41AA  
GPC14  
36H41AC  
Models  
Cooling Capacity  
Cooling Capacity (BTU/h)  
Sensible BTU/h  
SEER / EER  
24,600  
18,200  
14.5 / 12.1  
76  
28,400  
21,600  
14.0 / 12.1  
76  
28,400  
21,600  
14.0 / 12.1  
76  
35,600  
27,100  
35,600  
27,100  
14.0 / 12.0  
78  
14.0 / 12.0  
78  
Decibels  
AHRI Numbers  
4635463  
4635475  
4635464  
4635476  
4635465  
Evaporator Motor  
Type  
EEM  
10 x 8  
850  
EEM  
10 x 8  
1,050  
950  
EEM  
10 x 8  
1,050  
950  
EEM  
10 x 8  
1,200  
1,100  
1.86  
EEM  
10 x 8  
1,200  
1,100  
1.86  
Wheel (D x W)  
Cooling CFM  
Fan-Only CFM  
800  
RLA  
1.5  
1.86  
1.86  
No. of Speeds  
5
5
5
5
5
Horsepower - RPM  
Evaporator Coil  
Face Area (ſt²)  
½ - 1050  
½ - 1050  
½ - 1050  
½ - 1050  
½ - 1050  
5.25  
3/ 16  
0.057  
20 x 20 x 1  
¾"  
5.25  
3/ 16  
0.062  
20 x 25 x 1  
¾"  
5.25  
3/ 16  
0.062  
20 x 25 x 1  
¾"  
5.2  
3/ 14  
0.068  
25 x 25 x 1  
¾"  
5.2  
3/ 14  
0.068  
25 x 25 x 1  
¾"  
Rows Deep/ Fins per Inch  
Indoor Orifice Size  
Filter Size (”)  
Drain Size (NPT)  
Refrigerant Charge (oz.)  
Condenser Fan / Coil  
Horsepower - RPM  
RLA/LRA  
59  
78  
53  
80  
65  
1/6 - 815  
1.1 / 1.7  
22 / 2  
¼ - 830  
1.5 / 3.0  
22 / 3  
1/6 - 815  
1.1 / 1.7  
22 / 2  
¼ - 830  
1.5 / 3.0  
22 / 3  
¼ - 830  
1.5 / 3.0  
22 / 3  
Fan Diameter/ # Fan Blades  
Face Area (ſt²)  
12.3  
13.4  
12.3  
13.4  
12.3  
Rows Deep/ Fins per Inch  
Compressor  
1 / 26  
1 / 24  
1 / 26  
1 / 24  
1 / 26  
Quanꢀty  
1
1
1
1
1
Type  
Scroll  
Recip  
Single  
9.8 / 55  
Scroll  
Scroll  
Scroll  
Stage  
Single  
Single  
12.8 / 64  
Single  
16.7 / 79  
Single  
16.7 / 79  
Compressor RLA/LRA  
Electrical Data  
Voltage-Phase  
13.5 / 58.3  
208/230-1  
1.5  
208/230-1  
1.86  
1.5  
208/230-1  
1.86  
1.5  
208/230-1  
1.86  
1.5  
208/230-1  
1.86  
1.5  
Indoor Blower FLA  
Outdoor Fan RLA  
Total Unit Amps  
Min. Circuit Ampacity¹  
Max. Overcurrent Protecꢀon (amps)²  
Ship Weight (lbs)  
Operating Weight (lbs)  
1.1  
16.1  
19.5  
30  
13.16  
15.6  
25  
15.76  
19  
20.06  
24.2  
40  
20.06  
24.2  
40  
30  
290  
310  
290  
370  
370  
280  
300  
280  
360  
360  
¹ Wire size should be determined in accordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.  
² May use fuses or HACR-type circuit breakers of the same size as noted.  
Note: Always check the S&R plate for electrical data on the unit being installed.  
SS-GPC14H  
3
PRoDUcT SPeciFicATionS  
SPeciFicATionS  
GPC14  
42H41AA  
GPC14  
42H41AC  
GPC14  
48H41AA  
GPC14  
48H41AC  
GPC14  
60H41A*  
Models  
Cooling Capacity  
Cooling Capacity (BTU/h)  
Sensible BTU/h  
SEER / EER  
40,000  
30,400  
40,000  
30,400  
46,500  
35,300  
46,500  
35,300  
57,500  
40,800  
14.2 / 12.0  
78  
14.2 / 12.0  
78  
14.5 / 12.0  
80  
14.5 / 12.0  
80  
14.2 / 12.0  
80  
Decibels  
AHRI Numbers  
4635477  
4635466  
4635478  
4635467  
4385084  
Evaporator Motor  
Type  
EEM  
10 x 8  
1,300  
1,200  
2.9  
EEM  
10 x 8  
1,300  
1,200  
2.9  
EEM  
10 x 8  
1,600  
1,400  
2.9  
EEM  
10 x 8  
1,600  
1,400  
2.9  
EEM  
11 x 8  
1,600  
1,600  
2.9  
Wheel (D x W)  
Cooling CFM  
Fan-Only CFM  
RLA  
No. of Speeds  
5
5
5
5
5
Horsepower - RPM  
Evaporator Coil  
Face Area (ſt²)  
½ - 1050  
½ - 1050  
¾ - 1050  
¾ - 1050  
¾ - 1050  
6.2  
4/ 14  
6.2  
4/ 14  
6.2  
4/ 14  
6.2  
4/ 14  
7.0  
4/ 14  
Rows Deep/ Fins per Inch  
Indoor Orifice Size  
Filter Size (”)  
0.072  
0.072  
0.078  
0.078  
0.088  
(2) 20 x 20 x 1  
¾"  
(2) 20 x 20 x 1  
¾"  
(2) 20 x 20 x 1  
¾"  
(2) 20 x 20 x 1  
¾"  
(2) 20 x 25 x 1  
¾"  
Drain Size (NPT)  
Refrigerant Charge (oz.)  
Condenser Fan / Coil  
Horsepower - RPM  
RLA/LRA  
120  
94  
125  
90  
190  
¼ - 1075  
1.4 / 2.9  
22 / 4  
17  
¼ - 1075  
1.4 / 2.9  
22 / 4  
16  
¼ - 1075  
1.4 / 2.9  
22 / 4  
¼ - 1075  
1.4 / 2.9  
22 / 4  
¼ - 1075  
1.4 / 2.9  
22 / 4  
Fan Diameter/ # Fan Blades  
Face Area (ſt²)  
19.1  
19.5  
19.1  
Rows Deep/ Fins per Inch  
Compressor  
1 / 24  
1 / 28  
1 / 21  
1 / 28  
2 / 16  
Quanꢀty  
1
1
1
1
1
Type  
Scroll  
Scroll  
Scroll  
Scroll  
Scroll  
Stage  
Single  
Single  
Single  
Single  
Single  
Compressor RLA/LRA  
Electrical Data  
Voltage-Phase  
17.9 / 112  
17.9 / 112  
19.9 / 109  
19.9 / 109  
26.4 / 134  
208/230-1  
2.9  
208/230-1  
2.9  
208/230-1  
2.9  
208/230-1  
2.9  
208/230-1  
2.9  
Indoor Blower FLA  
Outdoor Fan RLA  
Total Unit Amps  
Min. Circuit Ampacity¹  
Max. Overcurrent Protecꢀon (amps)²  
Ship Weight (lbs)  
Operating Weight (lbs)  
1.4  
1.4  
1.4  
1.4  
1.4  
22.2  
26.6  
40  
22.2  
26.6  
40  
24.2  
29.1  
45  
24.2  
29.1  
45  
30.7  
37.3  
60  
370  
370  
400  
400  
400  
360  
360  
390  
390  
390  
¹ Wire size should be determined in accordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.  
² May use fuses or HACR-type circuit breakers of the same size as noted.  
Note: Always check the S&R plate for electrical data on the unit being installed.  
4
SS-GPC14H  
PRoDUcT SPeciFicATionS  
AiRFlow DATA  
E.S.P. (In. of H₂O)  
Model  
Speed  
Volts  
0.1  
934  
0.2  
759  
0.3  
755  
0.4  
638  
0.5  
581  
83  
0.6  
489  
90  
0.7  
-
0.8  
-
CFM  
T1  
T2,T3  
T4, T5  
T1  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
230  
Waꢁs  
CFM  
95  
77  
76  
73  
-
-
990  
837  
801  
744  
696  
119  
876  
169  
797  
144  
937  
185  
1124  
257  
933  
179  
1099  
213  
1181  
247  
1055  
211  
1147  
245  
1336  
303  
1275  
299  
1510  
455  
1590  
550  
1510  
455  
1725  
645  
652  
133  
-
601  
142  
-
-
GPC14  
24H41**  
Waꢁs  
CFM  
107  
94  
105  
110  
-
1061  
126  
989  
947  
925  
-
Waꢁs  
CFM  
134  
146  
158  
-
-
-
1022  
116  
929  
894  
829  
748  
156  
-
695  
168  
-
643  
173  
-
Waꢁs  
CFM  
114  
126  
134  
1103  
142  
1063  
154  
1012  
165  
962  
GPC14  
30H41**  
T2,T3  
T4, T5  
T1  
Waꢁs  
CFM  
173  
-
-
-
1285  
205  
1240  
218  
1202  
231  
1163  
244  
1076  
268  
922  
183  
1053  
221  
1144  
258  
998  
220  
1099  
255  
1293  
317  
1228  
308  
1450  
465  
1580  
560  
1450  
465  
1650  
655  
1046  
280  
-
1003  
288  
-
Waꢁs  
CFM  
1234  
144  
1111  
140  
1071  
152  
1024  
164  
Waꢁs  
CFM  
-
-
1287  
162  
1232  
175  
1186  
187  
1133  
201  
-
-
GPC14  
36H41**  
T2,T3  
T4, T5  
T1  
Waꢁs  
CFM  
-
-
1381  
195  
1325  
203  
1277  
217  
1233  
233  
-
-
Waꢁs  
CFM  
-
-
1272  
160  
1197  
168  
1145  
183  
1106  
191  
947  
230  
1049  
267  
1253  
329  
1178  
320  
1430  
470  
1530  
570  
1430  
470  
1620  
660  
906  
243  
1008  
284  
1208  
341  
1141  
338  
1400  
475  
1500  
575  
1400  
475  
1580  
670  
Waꢁs  
CFM  
1357  
188  
1297  
202  
1244  
213  
1194  
228  
GPC14  
42H41**  
T2,T3  
T4, T5  
T1  
Waꢁs  
CFM  
1537  
244  
1478  
258  
1431  
274  
1386  
288  
Waꢁs  
CFM  
1418  
242  
1383  
258  
1349  
273  
1312  
282  
Waꢁs  
CFM  
1175  
395  
1635  
420  
1645  
435  
1515  
445  
GPC14  
48H41**  
T2,T3  
T4, T5  
T1,T2,T3  
T4, T5  
Waꢁs  
CFM  
1845  
490  
1790  
505  
1715  
520  
1685  
535  
Waꢁs  
CFM  
1775  
395  
1635  
420  
1645  
435  
1515  
445  
Waꢁs  
CFM  
GPC14  
60H41**  
2025  
575  
1900  
595  
1840  
620  
1780  
630  
Waꢁs  
Note: Speed is set at T2 at factory.  
SS-GPC14H  
5
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1424H41Ac  
6
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1424H41Ac (conT.)  
SS-GPC14H  
7
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1430H41AA  
8
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1430H41AA (conT.)  
SS-GPC14H  
9
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1430H41Ac  
10  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1430H41Ac (conT.)  
SS-GPC14H  
11  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1436H41AA  
12  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1436H41AA (conT.)  
SS-GPC14H  
13  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1436H41Ac  
14  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1436H41Ac (conT.)  
SS-GPC14H  
15  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1442H41AA  
16  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1442H41AA (conT.)  
SS-GPC14H  
17  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1442H41Ac  
18  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1442H41Ac (conT.)  
SS-GPC14H  
19  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1448H41AA  
20  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1448H41AA (conT.)  
SS-GPC14H  
21  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1448H41Ac  
22  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1448H41Ac (conT.)  
SS-GPC14H  
23  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1460H41A*  
24  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
exPAnDeD cooling DATA gPc1460H41A* (conT.)  
SS-GPC14H  
25  
PRoDUcT SPeciFicATionS  
HeAT kiT elecTRicAl DATA (BloweR only, HeAT moDe)  
Circuit #1  
Circuit #2  
Actual kW /  
BTU@ 240V  
Model and Heat Kit Usage  
MCA¹  
MOD²  
--  
MCA¹  
MOD²  
GPC1424H41*  
1.5 / 1.5  
24 / 27  
33 / 38  
45 / 51  
2.4 / 2.4  
24 / 27  
34 / 39  
45 / 52  
45 / 52  
2.4 / 2.4  
24 / 27  
34 / 39  
45 / 52  
45 / 52  
3.9 / 3.9  
25 / 27  
34 / 39  
46 / 52  
46 / 52  
46 / 52  
3.9 / 3.9  
25 / 28  
34 / 40  
46 / 53  
46 / 52  
46 / 52  
6.0 / 6.0  
26 / 30  
36 / 40  
48 / 54  
48 / 54  
48 / 54  
--  
--  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
GPC1430H41*  
30 / 30  
40 / 40  
60 / 60  
--  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
--  
--  
--  
--  
--  
--  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
HKR-15*, HKR-15C*  
GPC1436H41*  
30 / 30  
40 / 40  
60 / 60  
60 / 60  
--  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
14.25 / 48,600  
--  
--  
--  
--  
--  
22 / 25  
30 / 30  
--  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
HKR-15*, HKR-15C*  
GPC1442H41*  
30 / 30  
40 / 40  
60 / 60  
60 / 60  
--  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
14.25 / 48,600  
--  
--  
--  
--  
--  
22 / 25  
30 / 30  
--  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
HKR-15*, HKR-15C*  
HKR-20*,HKR-20C*  
GPC1448H41*  
30 / 30  
40 / 40  
60 / 60  
60 / 60  
60 / 60  
--  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
14.25 / 48,600  
19.5 / 66,500  
--  
--  
--  
--  
--  
22 / 25  
30 / 30  
43 / 49  
60 / 60  
--  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
HKR-15*, HKR-15C*  
HKR-20*,HKR-20C*  
GPC1460H41*  
30 / 30  
40 / 40  
60 / 60  
60 / 60  
60 / 60  
--  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
14.25 / 48,600  
19.5 / 66,500  
--  
--  
--  
--  
22 / 25  
43 / 49  
--  
--  
30 / 30  
60 / 60  
--  
HKR-05*, HKR-05C*  
HKR-08*, HKR-08C*  
HKR-10*, HKR-10C*  
HKR-15*, HKR-15C*  
HKR-20*,HKR-20C*  
30 / 30  
40 / 40  
60 / 60  
60 / 60  
60 / 60  
--  
--  
4.75 / 16,200  
7 / 23,800  
9.5 / 32,400  
14.25 / 48,600  
19.5 / 66,500  
--  
--  
--  
--  
22 / 25  
43 / 49  
30 / 30  
60 / 60  
¹
²
*
Minimum Circuit Ampacity @ 208 / 240V  
Maximum Overcurrent Protecꢀon (amps) @ 208 / 240V  
Indicates revision leꢁer that may or may not be designated  
26  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
DimenSionS  
66.25”  
A
34.075”  
A Dimensions  
Model  
Chassis Size  
Height  
GPC1424  
GPC1430  
minimAl cleARAnceS  
Small  
30”  
GPC1436  
GPC1442  
Medium  
Large  
35”  
GPC1448  
GPC1460  
38¾”  
SS-GPC14H  
27  
PRoDUcT SPeciFicATionS  
wiRing DiAgRAm — gPc1424-60H41AA  
PU  
NOTE #3  
BK  
2
BK  
PU  
PU  
1
C
3
240  
BL  
208  
BK  
2
0
8
-
2
4
0
/
TR  
BL  
T2  
T1  
L2  
RD  
24V  
RD  
C
BL  
SEE NOTE 5  
L1  
BK  
BK  
RD  
1
/
YL  
GND  
GR  
BK  
60  
RD  
RD  
YL  
PU  
LVJB  
YL  
H
T
H
E
R
M
O
S
T
WH  
RD  
C
BR  
F
WH  
PLF  
YL  
RD  
GR  
WH  
Y
R
G
GR  
BL  
3
2
1
6
5
4
9
8
7
W1  
YL  
RCCF  
BL  
GR  
BR  
BR  
BL  
W2  
C
A
T
++  
PU  
BR  
RD  
BK  
BK  
SA  
(IF USED) SEE NOTE 4  
CONTROL  
BOX  
RD  
C
BK  
YL  
PU BR  
CM  
YL  
GR  
WH  
S
R
C
L
2
G
3
N
4
1
5
HPS  
COMP  
WH  
EM  
SEE NOTE 2  
L1  
L2  
COMPONENT LEGEND  
CONTACTOR  
FACTORY WIRING  
SUPPLY VOLTAGE  
208-240/1/60  
LINE VOLTAGE  
LOW VOLTAGE  
OPTINAL HIGH  
VOLTAGE  
C
CM  
CONDENSER MOTOR  
COMP  
COMPRESSOR  
EM  
EVAPORATOR MOTOR  
EQUIPMENT GROUND  
T2  
C
GND  
LVJB  
PLF  
RCCF  
R
COMP  
C
T1  
FIELD WIRING  
HIGH VOLTAGE  
LOW VOLTAGE  
LOW VOLTAGE JUNCTION BOX  
FEMALE PLUG / CONNECTOR  
RUN CAPACITOR FOR  
COMPRESSOR AND FAN  
START ASSIST  
C
C
RCCF  
S
H
F
S.A.  
CM  
SA  
TR  
NOTE #4  
TRANSFORMER  
WIRE CODE  
BK BLACK  
BL BLUE  
BR BROWN  
GR GREEN  
OR ORANGE  
PU PURPLE  
RD RED  
HPS  
HIGH PRESSURE SWITCH  
IF USED  
NOTE #2  
EM  
L
N
3
G
1
2
WH WHITE  
YL YELLOW  
208-240  
2
NOTE #4  
3
1
TR  
24V  
NOTES:  
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS  
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.  
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW  
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE  
ENERGIZED, THE HIGHER SPEED SETTING IS USED.  
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES  
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.  
4. START ASSIST FACTORY EQUIPED WHEN REQUIRED  
5. USE COPPER CONDUCTORS ONLY.  
C
1
2
EM  
SEE NOTE #2  
3
++ USE N.E.C. CLASS 2 WIRE  
4
5
6
PLF  
SEE UNIT RATING PLATE FOR TYPE AND SIZE  
OF OVER CURRENT PROTECTION  
C
HPS  
R
W2  
W1  
Y
G
C
THERMOSTAT  
208-240/1/60 0140G00871 REV. B  
28  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
wiRing DiAgRAm — gPc1424-48H41Ac  
PU  
NOTE #3  
BK  
BK  
PU  
PU  
1
C
2
208  
3
240  
BL  
BK  
2
0
8
-
2
4
0
/
TR  
BL  
T2  
T1  
L2  
RD  
24V  
RD  
C
BL  
SEE NOTE 5  
L1  
BK  
BK  
RD  
1
/
YL  
GND  
GR  
BK  
60  
RD  
RD  
YL  
PU  
LVJB  
YL  
T
H
E
R
M
O
S
T
WH  
RD  
C
BR  
WH  
PLF  
YL  
RD  
GR  
WH  
Y
R
G
GR  
BL  
3
2
1
6
5
4
9
8
7
W1  
YL  
H
F
RCCF  
BL  
GR  
BR  
BR  
BL  
W2  
C
A
T
  
PU  
BR  
RD  
SA  
(IF USED) SEE NOTE 4  
BK  
BK  
RD  
C
BK  
CONTROL  
BOX  
YL  
PU BR  
YL  
GR  
WH  
S
R
C
L
2
G
3
N
4
1
5
CM  
COMP  
WH  
EM  
SEE NOTE 2  
L1  
L2  
COMPONENT LEGEND  
CONTACTOR  
FACTORY WIRING  
LINE VOLTAGE  
LOW VOLTAGE  
OPTINAL HIGH  
VOLTAGE  
SUPPLY VOLTAGE  
208-240/1/60  
C
CM  
CONDENSER MOTOR  
COMPRESSOR  
EVAPORATOR MOTOR  
EQUIPMENT GROUND  
LOW VOLTAGE JUNCTION BOX  
FEMALE PLUG / CONNECTOR  
RUN CAPACITOR FOR  
COMPRESSOR AND FAN  
START ASSIST  
COMP  
EM  
GND  
LVJB  
PLF  
T2  
C
R
COMP  
C
T1  
FIELD WIRING  
HIGH VOLTAGE  
LOW VOLTAGE  
C
C
RCCF  
S
H
RCCF  
F
S.A.  
CM  
SA  
TR  
NOTE #4  
TRANSFORMER  
WIRE CODE  
BK BLACK  
BL BLUE  
IF USED  
NOTE #2  
EM  
BR BROWN  
GR GREEN  
OR ORANGE  
PU PURPLE  
RD RED  
L
N
3
G
1
2
WH WHITE  
YL YELLOW  
208-240  
2
NOTE #4  
3
1
TR  
24V  
NOTES:  
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS  
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.  
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW  
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE  
ENERGIZED, THE HIGHER SPEED SETTING IS USED.  
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES  
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.  
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED  
5. USE COPPER CONDUCTORS ONLY.  
C
1
2
EM  
SEE NOTE #2  
3
++ USE N.E.C. CLASS 2 WIRE  
4
5
6
PLF  
SEE UNIT RATING PLATE FOR TYPE AND SIZE  
OF OVER CURRENT PROTECTION  
C
R
W2  
W1  
Y
G
C
THERMOSTAT  
208-240/1/60 0140G00407  
SS-GPC14H  
29  
PRoDUcT SPeciFicATionS  
AcceSSoRieS  
Item  
OT/EHR18-60  
OT18-60A  
Description  
Emergency Heat Relay kit  
Outdoor Thermostat Kit with Lockout Stat  
Roof Curb for for Medium/Large Chassis  
PCCP102/103  
PCE102/103  
Downflow Economizer for for Medium/Large Chassis  
Elbow & Flashing w/ R-8 Liner for Medium/Large Chassis  
External Horizontal Filter Rack for Medium/Large Chassis  
Manual Damper for Medium/Large Chassis  
PCEF102/103  
PCFR102/103  
PCMD102/103  
PCMDH102/103  
PCMDM102/103  
PCP102/103  
Manual Damper for Medium/Large Chassis — Horizontal Applicaꢀons  
Motorized Damper for Medium/Large Chassis  
Downflow Plenum Kit for Medium/Large Chassis  
PCP102/103R8  
SQRPC101  
Downflow Plenum Kit for Medium/Large Chassis  
Square-to-Round Adapter for Small Chassis — 16” Rounds  
Square-to-Round Adapter for Medium/Large Chassis — 18” Rounds  
Square-to-Round Adapters Small Chassis for Small Chassis — 16” x 14”  
Square-to-Round Adapters for Medium/Large Chassis — 18” x 14”  
SQRPC102-103  
SQRPCH101  
SQRPCH102-103  
30  
SS-GPC14H  
PRoDUcT SPeciFicATionS  
noTeS  
SS-GPC14H  
31  
PRoDUcT SPeciFicATionS  
noTeS  
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without  
notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. Houston, Texas • Printed in the USA.  
32  
SS-GPC14H  

Canon PIXMA MX410 User Manual
Danby DAC10010E User Manual
Epson WorkForce 600 User Manual
Friedrich MR12C1H User Manual
GE ASV12AK User Manual
Goodman Mfg AVPTC426014AA User Manual
Haier AD362AMERA User Manual
Heat Controller Inc Air Conditioner BG 101G User Manual
Heat Controller Inc Air Conditioner RADS 51B User Manual
Heat Controller PD 91B User Manual