GPC14H
2- to 5-ton
Packaged air conditioner
up to 14 SEER
cooling caPacity: 24,000 - 57,500 BtU/H
Product Features
• Energy-efficient compressor
with internal relief valve
• EEM blower motor
• Quiet horizontal discharge
• Copper tube/aluminum fin coil
• Totally enclosed, permanently lubricated
condenser fan motor
• Fully charged system
• 5 kW to 20 kW electric heat kit available
as a field-installed option
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with
attractive Architectural Gray powder-paint finish
• Fully insulated blower compartment
with convenient access panels
• Louvered condenser coil protection
• One footprint; three heights
Contents
Nomenclature......................................................................... 2
Product Specifications ............................................................ 3
Airflow Data ............................................................................ 5
Expanded Cooling Data .......................................................... 6
Heater Kit Specifications ...................................................... 26
Dimensions ........................................................................... 27
Wiring Diagrams ................................................................... 28
Accessories ............................................................................ 30
manmfg.com. To receive the 10-Year Parts Limited Warranty, online registration
must be completed within 60 days of installation. Online registration is not
required in California or Québec
.
SS-GPC14H
7/11
Supersedes 6/11
Product SPecificationS
SPecificationS
GPC14
24H41AC
GPC14
30H41AA
GPC14
30H41AC
GPC14
36H41AA
GPC14
36H41AC
Models
Cooling Capacity
Cooling Capacity (BTU/h)
Sensible BTU/h
SEER / EER
24,600
18,200
14.5 / 12.1
76
28,400
21,600
14.0 / 12.1
76
28,400
21,600
14.0 / 12.1
76
35,600
27,100
35,600
27,100
14.0 / 12.0
78
14.0 / 12.0
78
Decibels
AHRI Numbers
4635463
4635475
4635464
4635476
4635465
Evaporator Motor
Type
EEM
10 x 8
850
EEM
10 x 8
1,050
950
EEM
10 x 8
1,050
950
EEM
10 x 8
1,200
1,100
1.86
EEM
10 x 8
1,200
1,100
1.86
Wheel (D x W)
Cooling CFM
Fan-Only CFM
800
RLA
1.5
1.86
1.86
No. of Speeds
5
5
5
5
5
Horsepower - RPM
Evaporator Coil
Face Area (ſt²)
½ - 1050
½ - 1050
½ - 1050
½ - 1050
½ - 1050
5.25
3/ 16
0.057
20 x 20 x 1
¾"
5.25
3/ 16
0.062
20 x 25 x 1
¾"
5.25
3/ 16
0.062
20 x 25 x 1
¾"
5.2
3/ 14
0.068
25 x 25 x 1
¾"
5.2
3/ 14
0.068
25 x 25 x 1
¾"
Rows Deep/ Fins per Inch
Indoor Orifice Size
Filter Size (”)
Drain Size (NPT)
Refrigerant Charge (oz.)
Condenser Fan / Coil
Horsepower - RPM
RLA/LRA
59
78
53
80
65
1/6 - 815
1.1 / 1.7
22 / 2
¼ - 830
1.5 / 3.0
22 / 3
1/6 - 815
1.1 / 1.7
22 / 2
¼ - 830
1.5 / 3.0
22 / 3
¼ - 830
1.5 / 3.0
22 / 3
Fan Diameter/ # Fan Blades
Face Area (ſt²)
12.3
13.4
12.3
13.4
12.3
Rows Deep/ Fins per Inch
Compressor
1 / 26
1 / 24
1 / 26
1 / 24
1 / 26
Quanꢀty
1
1
1
1
1
Type
Scroll
Recip
Single
9.8 / 55
Scroll
Scroll
Scroll
Stage
Single
Single
12.8 / 64
Single
16.7 / 79
Single
16.7 / 79
Compressor RLA/LRA
Electrical Data
Voltage-Phase
13.5 / 58.3
208/230-1
1.5
208/230-1
1.86
1.5
208/230-1
1.86
1.5
208/230-1
1.86
1.5
208/230-1
1.86
1.5
Indoor Blower FLA
Outdoor Fan RLA
Total Unit Amps
Min. Circuit Ampacity¹
Max. Overcurrent Protecꢀon (amps)²
Ship Weight (lbs)
Operating Weight (lbs)
1.1
16.1
19.5
30
13.16
15.6
25
15.76
19
20.06
24.2
40
20.06
24.2
40
30
290
310
290
370
370
280
300
280
360
360
¹ Wire size should be determined in accordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
SS-GPC14H
3
PRoDUcT SPeciFicATionS
SPeciFicATionS
GPC14
42H41AA
GPC14
42H41AC
GPC14
48H41AA
GPC14
48H41AC
GPC14
60H41A*
Models
Cooling Capacity
Cooling Capacity (BTU/h)
Sensible BTU/h
SEER / EER
40,000
30,400
40,000
30,400
46,500
35,300
46,500
35,300
57,500
40,800
14.2 / 12.0
78
14.2 / 12.0
78
14.5 / 12.0
80
14.5 / 12.0
80
14.2 / 12.0
80
Decibels
AHRI Numbers
4635477
4635466
4635478
4635467
4385084
Evaporator Motor
Type
EEM
10 x 8
1,300
1,200
2.9
EEM
10 x 8
1,300
1,200
2.9
EEM
10 x 8
1,600
1,400
2.9
EEM
10 x 8
1,600
1,400
2.9
EEM
11 x 8
1,600
1,600
2.9
Wheel (D x W)
Cooling CFM
Fan-Only CFM
RLA
No. of Speeds
5
5
5
5
5
Horsepower - RPM
Evaporator Coil
Face Area (ſt²)
½ - 1050
½ - 1050
¾ - 1050
¾ - 1050
¾ - 1050
6.2
4/ 14
6.2
4/ 14
6.2
4/ 14
6.2
4/ 14
7.0
4/ 14
Rows Deep/ Fins per Inch
Indoor Orifice Size
Filter Size (”)
0.072
0.072
0.078
0.078
0.088
(2) 20 x 20 x 1
¾"
(2) 20 x 20 x 1
¾"
(2) 20 x 20 x 1
¾"
(2) 20 x 20 x 1
¾"
(2) 20 x 25 x 1
¾"
Drain Size (NPT)
Refrigerant Charge (oz.)
Condenser Fan / Coil
Horsepower - RPM
RLA/LRA
120
94
125
90
190
¼ - 1075
1.4 / 2.9
22 / 4
17
¼ - 1075
1.4 / 2.9
22 / 4
16
¼ - 1075
1.4 / 2.9
22 / 4
¼ - 1075
1.4 / 2.9
22 / 4
¼ - 1075
1.4 / 2.9
22 / 4
Fan Diameter/ # Fan Blades
Face Area (ſt²)
19.1
19.5
19.1
Rows Deep/ Fins per Inch
Compressor
1 / 24
1 / 28
1 / 21
1 / 28
2 / 16
Quanꢀty
1
1
1
1
1
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Stage
Single
Single
Single
Single
Single
Compressor RLA/LRA
Electrical Data
Voltage-Phase
17.9 / 112
17.9 / 112
19.9 / 109
19.9 / 109
26.4 / 134
208/230-1
2.9
208/230-1
2.9
208/230-1
2.9
208/230-1
2.9
208/230-1
2.9
Indoor Blower FLA
Outdoor Fan RLA
Total Unit Amps
Min. Circuit Ampacity¹
Max. Overcurrent Protecꢀon (amps)²
Ship Weight (lbs)
Operating Weight (lbs)
1.4
1.4
1.4
1.4
1.4
22.2
26.6
40
22.2
26.6
40
24.2
29.1
45
24.2
29.1
45
30.7
37.3
60
370
370
400
400
400
360
360
390
390
390
¹ Wire size should be determined in accordance with Naꢀonal Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Note: Always check the S&R plate for electrical data on the unit being installed.
4
SS-GPC14H
PRoDUcT SPeciFicATionS
AiRFlow DATA
E.S.P. (In. of H₂O)
Model
Speed
Volts
0.1
934
0.2
759
0.3
755
0.4
638
0.5
581
83
0.6
489
90
0.7
-
0.8
-
CFM
T1
T2,T3
T4, T5
T1
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
Waꢁs
CFM
95
77
76
73
-
-
990
837
801
744
696
119
876
169
797
144
937
185
1124
257
933
179
1099
213
1181
247
1055
211
1147
245
1336
303
1275
299
1510
455
1590
550
1510
455
1725
645
652
133
-
601
142
-
-
GPC14
24H41**
Waꢁs
CFM
107
94
105
110
-
1061
126
989
947
925
-
Waꢁs
CFM
134
146
158
-
-
-
1022
116
929
894
829
748
156
-
695
168
-
643
173
-
Waꢁs
CFM
114
126
134
1103
142
1063
154
1012
165
962
GPC14
30H41**
T2,T3
T4, T5
T1
Waꢁs
CFM
173
-
-
-
1285
205
1240
218
1202
231
1163
244
1076
268
922
183
1053
221
1144
258
998
220
1099
255
1293
317
1228
308
1450
465
1580
560
1450
465
1650
655
1046
280
-
1003
288
-
Waꢁs
CFM
1234
144
1111
140
1071
152
1024
164
Waꢁs
CFM
-
-
1287
162
1232
175
1186
187
1133
201
-
-
GPC14
36H41**
T2,T3
T4, T5
T1
Waꢁs
CFM
-
-
1381
195
1325
203
1277
217
1233
233
-
-
Waꢁs
CFM
-
-
1272
160
1197
168
1145
183
1106
191
947
230
1049
267
1253
329
1178
320
1430
470
1530
570
1430
470
1620
660
906
243
1008
284
1208
341
1141
338
1400
475
1500
575
1400
475
1580
670
Waꢁs
CFM
1357
188
1297
202
1244
213
1194
228
GPC14
42H41**
T2,T3
T4, T5
T1
Waꢁs
CFM
1537
244
1478
258
1431
274
1386
288
Waꢁs
CFM
1418
242
1383
258
1349
273
1312
282
Waꢁs
CFM
1175
395
1635
420
1645
435
1515
445
GPC14
48H41**
T2,T3
T4, T5
T1,T2,T3
T4, T5
Waꢁs
CFM
1845
490
1790
505
1715
520
1685
535
Waꢁs
CFM
1775
395
1635
420
1645
435
1515
445
Waꢁs
CFM
GPC14
60H41**
2025
575
1900
595
1840
620
1780
630
Waꢁs
Note: Speed is set at T2 at factory.
SS-GPC14H
5
PRoDUcT SPeciFicATionS
HeAT kiT elecTRicAl DATA (BloweR only, HeAT moDe)
Circuit #1
Circuit #2
Actual kW /
BTU@ 240V
Model and Heat Kit Usage
MCA¹
MOD²
--
MCA¹
MOD²
GPC1424H41*
1.5 / 1.5
24 / 27
33 / 38
45 / 51
2.4 / 2.4
24 / 27
34 / 39
45 / 52
45 / 52
2.4 / 2.4
24 / 27
34 / 39
45 / 52
45 / 52
3.9 / 3.9
25 / 27
34 / 39
46 / 52
46 / 52
46 / 52
3.9 / 3.9
25 / 28
34 / 40
46 / 53
46 / 52
46 / 52
6.0 / 6.0
26 / 30
36 / 40
48 / 54
48 / 54
48 / 54
--
--
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
GPC1430H41*
30 / 30
40 / 40
60 / 60
--
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
--
--
--
--
--
--
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15*, HKR-15C*
GPC1436H41*
30 / 30
40 / 40
60 / 60
60 / 60
--
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
14.25 / 48,600
--
--
--
--
--
22 / 25
30 / 30
--
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15*, HKR-15C*
GPC1442H41*
30 / 30
40 / 40
60 / 60
60 / 60
--
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
14.25 / 48,600
--
--
--
--
--
22 / 25
30 / 30
--
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15*, HKR-15C*
HKR-20*,HKR-20C*
GPC1448H41*
30 / 30
40 / 40
60 / 60
60 / 60
60 / 60
--
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
14.25 / 48,600
19.5 / 66,500
--
--
--
--
--
22 / 25
30 / 30
43 / 49
60 / 60
--
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15*, HKR-15C*
HKR-20*,HKR-20C*
GPC1460H41*
30 / 30
40 / 40
60 / 60
60 / 60
60 / 60
--
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
14.25 / 48,600
19.5 / 66,500
--
--
--
--
22 / 25
43 / 49
--
--
30 / 30
60 / 60
--
HKR-05*, HKR-05C*
HKR-08*, HKR-08C*
HKR-10*, HKR-10C*
HKR-15*, HKR-15C*
HKR-20*,HKR-20C*
30 / 30
40 / 40
60 / 60
60 / 60
60 / 60
--
--
4.75 / 16,200
7 / 23,800
9.5 / 32,400
14.25 / 48,600
19.5 / 66,500
--
--
--
--
22 / 25
43 / 49
30 / 30
60 / 60
¹
²
*
Minimum Circuit Ampacity @ 208 / 240V
Maximum Overcurrent Protecꢀon (amps) @ 208 / 240V
Indicates revision leꢁer that may or may not be designated
26
SS-GPC14H
PRoDUcT SPeciFicATionS
DimenSionS
66.25”
A
34.075”
A Dimensions
Model
Chassis Size
Height
GPC1424
GPC1430
minimAl cleARAnceS
Small
30”
GPC1436
GPC1442
Medium
Large
35”
GPC1448
GPC1460
38¾”
SS-GPC14H
27
PRoDUcT SPeciFicATionS
wiRing DiAgRAm — gPc1424-60H41AA
PU
NOTE #3
BK
2
BK
PU
PU
1
C
3
240
BL
208
BK
2
0
8
-
2
4
0
/
TR
BL
T2
T1
L2
RD
24V
RD
C
BL
SEE NOTE 5
L1
BK
BK
RD
1
/
YL
GND
GR
BK
60
RD
RD
YL
PU
LVJB
YL
H
T
H
E
R
M
O
S
T
WH
RD
C
BR
F
WH
PLF
YL
RD
GR
WH
Y
R
G
GR
BL
3
2
1
6
5
4
9
8
7
W1
YL
RCCF
BL
GR
BR
BR
BL
W2
C
A
T
++
PU
BR
RD
BK
BK
SA
(IF USED) SEE NOTE 4
CONTROL
BOX
RD
C
BK
YL
PU BR
CM
YL
GR
WH
S
R
C
L
2
G
3
N
4
1
5
HPS
COMP
WH
EM
SEE NOTE 2
L1
L2
COMPONENT LEGEND
CONTACTOR
FACTORY WIRING
SUPPLY VOLTAGE
208-240/1/60
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
C
CM
CONDENSER MOTOR
COMP
COMPRESSOR
EM
EVAPORATOR MOTOR
EQUIPMENT GROUND
T2
C
GND
LVJB
PLF
RCCF
R
COMP
C
T1
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
C
C
RCCF
S
H
F
S.A.
CM
SA
TR
NOTE #4
TRANSFORMER
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
HPS
HIGH PRESSURE SWITCH
IF USED
NOTE #2
EM
L
N
3
G
1
2
WH WHITE
YL YELLOW
208-240
2
NOTE #4
3
1
TR
24V
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTORY EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY.
C
1
2
EM
SEE NOTE #2
3
++ USE N.E.C. CLASS 2 WIRE
4
5
6
PLF
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
C
HPS
R
W2
W1
Y
G
C
THERMOSTAT
208-240/1/60 0140G00871 REV. B
28
SS-GPC14H
PRoDUcT SPeciFicATionS
wiRing DiAgRAm — gPc1424-48H41Ac
PU
NOTE #3
BK
BK
PU
PU
1
C
2
208
3
240
BL
BK
2
0
8
-
2
4
0
/
TR
BL
T2
T1
L2
RD
24V
RD
C
BL
SEE NOTE 5
L1
BK
BK
RD
1
/
YL
GND
GR
BK
60
RD
RD
YL
PU
LVJB
YL
T
H
E
R
M
O
S
T
WH
RD
C
BR
WH
PLF
YL
RD
GR
WH
Y
R
G
GR
BL
3
2
1
6
5
4
9
8
7
W1
YL
H
F
RCCF
BL
GR
BR
BR
BL
W2
C
A
T
PU
BR
RD
SA
(IF USED) SEE NOTE 4
BK
BK
RD
C
BK
CONTROL
BOX
YL
PU BR
YL
GR
WH
S
R
C
L
2
G
3
N
4
1
5
CM
COMP
WH
EM
SEE NOTE 2
L1
L2
COMPONENT LEGEND
CONTACTOR
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTINAL HIGH
VOLTAGE
SUPPLY VOLTAGE
208-240/1/60
C
CM
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
COMP
EM
GND
LVJB
PLF
T2
C
R
COMP
C
T1
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
C
C
RCCF
S
H
RCCF
F
S.A.
CM
SA
TR
NOTE #4
TRANSFORMER
WIRE CODE
BK BLACK
BL BLUE
IF USED
NOTE #2
EM
BR BROWN
GR GREEN
OR ORANGE
PU PURPLE
RD RED
L
N
3
G
1
2
WH WHITE
YL YELLOW
208-240
2
NOTE #4
3
1
TR
24V
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
LEADS FROM EM "2" AND "3" TO "4" AND "5". IF BOTH LEADS ARE
ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3. FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4. START ASSIST FACTOR EQUIPED WHEN REQUIRED
5. USE COPPER CONDUCTORS ONLY.
C
1
2
EM
SEE NOTE #2
3
++ USE N.E.C. CLASS 2 WIRE
4
5
6
PLF
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
C
R
W2
W1
Y
G
C
THERMOSTAT
208-240/1/60 0140G00407
SS-GPC14H
29
PRoDUcT SPeciFicATionS
AcceSSoRieS
Item
OT/EHR18-60
OT18-60A
Description
Emergency Heat Relay kit
Outdoor Thermostat Kit with Lockout Stat
Roof Curb for for Medium/Large Chassis
PCCP102/103
PCE102/103
Downflow Economizer for for Medium/Large Chassis
Elbow & Flashing w/ R-8 Liner for Medium/Large Chassis
External Horizontal Filter Rack for Medium/Large Chassis
Manual Damper for Medium/Large Chassis
PCEF102/103
PCFR102/103
PCMD102/103
PCMDH102/103
PCMDM102/103
PCP102/103
Manual Damper for Medium/Large Chassis — Horizontal Applicaꢀons
Motorized Damper for Medium/Large Chassis
Downflow Plenum Kit for Medium/Large Chassis
PCP102/103R8
SQRPC101
Downflow Plenum Kit for Medium/Large Chassis
Square-to-Round Adapter for Small Chassis — 16” Rounds
Square-to-Round Adapter for Medium/Large Chassis — 18” Rounds
Square-to-Round Adapters Small Chassis for Small Chassis — 16” x 14”
Square-to-Round Adapters for Medium/Large Chassis — 18” x 14”
SQRPC102-103
SQRPCH101
SQRPCH102-103
30
SS-GPC14H
PRoDUcT SPeciFicATionS
noTeS
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. © 2011 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
32
SS-GPC14H
|