TABLE OF CONTENTS  
Safety Precautions ..........................................................................................................................................  
3
Operating Instructions ..................................................................................................................................7  
Controls.................................................................................................................................................... 7  
Remote control......................................................................................................................................... 8  
Disassembly instructions ............................................................................................................................. 9  
Mechanical Parts...................................................................................................................................... 9  
Air Handling Parts ...................................................................................................................................10  
Electrical Parts ........................................................................................................................................11  
Refrigeration Cycle..................................................................................................................................13  
Schematic Diagram........................................................................................................................................16  
Wiring Diagram........................................................................................................................................16  
Troubleshooting Guide ................................................................................................................................17  
Piping System .........................................................................................................................................17  
Troubleshooting Guide ............................................................................................................................18  
Room Air Conditioner Voltage Limits.......................................................................................................21  
Product specifications....................................................................................................................................23~25  
Exploded Vi ew .............................................................................................................................................26  
Replacement Parts List ...............................................................................................................................27~29  
2 Room Air Conditioner  
Safety Precautions  
Safety Precautions  
To prevent injury to the user or other people and property damage, the following instructions must  
be followed.  
I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is  
classified by the following indications.  
This symbol indicates the possibility of death or serious injury.  
WARNING  
CAUTION This symbol indicates the possibility of injury or damage to property only.  
I Meanings of symbols used in this manual are as shown below.  
Be sure not to do.  
Be sure to follow the instruction.  
WARNING  
I Installation  
Don’t use a power cord, a plug  
or a loose socket which is dam-  
aged.  
Always plug into a grounded  
outlet.  
Do not modify or extend the  
power cord length.  
• Otherwise, it may cause a fire or  
electrical shock.  
• Otherwise, it may cause a fire or  
electrical shock.  
• It will cause electric shock or fire  
due to heat generation.  
Coo  
Ene  
l
Sa  
r
gy  
er  
an  
F
He  
at  
F
2
H
O
IG  
H
W
Tim  
T
MO  
er  
Co  
DE  
'
F
E
n
o
l
TEM  
S
e
r
g
y
IMER  
P
er  
n
SPFAN  
EE  
He  
D
at  
F1  
P
O
F
2
H
O
W
W
R  
Tim  
IGH  
MO  
er  
DE  
TE  
'
F
TIM  
M
ER  
P
D
SPF  
A
N
EE  
PO  
W
ER  
Do not disassemble or modify  
products.  
Be caution when unpacking and  
installing.  
Do not use the power cord near flam-  
mable gas or combustibles such as  
gasoline, benzene, thinner, etc.  
• It may cause failure and electric  
shock.  
• Sharp edges may cause injury.  
• It may cause explosion or fire.  
Coo  
Ene  
l
Sa  
r
gy  
er  
an  
F
Hea  
t
F1 LO  
W
Timer  
TIM  
2
HIG  
H
MO  
DE  
TEMP  
'
F
ER  
S
P
A
N
EE  
D
PO  
WE  
R
Co  
E
n
e
o
l
Sa  
r
gy  
er  
an  
He  
at  
L
O
IG  
H
F2  
H
W
Tim  
er  
MO  
DE  
'
F
TIM  
TEMP  
F
Coo  
ER  
Ene  
l
Sa  
r
gy  
S
P
A
N
er  
an  
EE  
F
D
Hea  
PO  
W
R  
t
F
2
L
O
Timer  
TIM  
HIG  
W
H
MO  
DE  
TEMP  
'
F
ER  
S
P
A
N
EE  
D
PO  
WE  
R
Gasolin  
Service Manual 3  
Safety Precautions  
I Operation  
Do not place heavy object on the  
power cord and take care so that  
the cord should not be pressed.  
Do not share the outlet with  
other appliances.  
Take the power plug out if neces-  
sary, holding the head of the plug  
and do not touch it with wet hands.  
• There is danger of fire or electric  
shock.  
• It will cause electric shock or fire  
due to heat generation.  
• Otherwise, it may cause a fire or  
electrical shock.  
Coo  
Ene  
l
Sa  
r
gy  
er  
an  
F
Hea  
t
F
2
L
O
Timer  
TIM  
HIG  
H
W
MO  
DE  
'
F
TEMP  
ER  
Coo  
Ene  
l
SPF  
A
N
ED  
Sa  
r
gy  
er  
an  
F
PO  
E  
He  
at  
F
2
H
O
 I
Tim  
GH  
MO  
er  
DE  
'
F
TIM  
ER  
TEMP  
SPF  
A
NE  
E
D
PO  
WE  
R
Do not place the power cord  
near a heater.  
Do not allow water to run into  
electric parts.  
Use a soft cloth to clean. Do not  
use wax, thinner, or a strong  
detergent.  
• The appearance of the air condi-  
tioner may deteriorate, change  
color, or develop surface flaws.  
• It may cause fire and electric  
shock.  
• It will cause failure of machine or  
electric shock.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F1  
F
2
H
O
 I
Tim  
GH  
MO  
er  
DE  
TIM  
ER  
TEM  
'
F
P
SPF  
A
NE  
E
D
PO  
WE  
Coo  
Ene  
l
Sa  
r
gy  
er  
F
a
n
Hea  
t
F1 LO  
W
2
HIG  
H
MODE  
Timer  
TIM  
TEMP  
'
F
ER  
S
P
A
N
EE  
D
PO  
W
R
Co  
E
n
e
o
l
Sa  
r
gy  
er  
an  
Hea  
F
t
F
1
L
O
2
HIG  
H
W
Tim  
er  
MO  
DE  
'
F
TIM  
ER  
TEMP  
SPF  
A
NE  
E
D
O  
WE  
R
x
Thinner  
Wa  
Unplug the unit if strange  
sounds, odors, or smoke come  
from it.  
Do not open the suction inlet  
grill of the product during opera-  
tion.  
If water enters the product, turn off the the  
power switch of the main body of appliance.  
Contact service center after taking the  
power-plug out from the socket.  
• Otherwise, it may electrical  
shock and failure.  
• Otherwise it may cause fire and  
electric shock accident.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
an  
He  
at  
F1  
F
2
H
O
 I
Tim  
er  
GH  
MO  
DE  
TIM  
ER  
TEM  
'
F
P
SPF  
A
NE  
E
D
PO  
WE  
R
Co  
E
n
e
o
l
Sa  
r
gy  
er  
an  
Hea  
F
t
F
1
L
O
2
HIG  
H
W
Tim  
er  
MO  
DE  
'
F
TIM  
TEMP  
ER  
SPF  
A
NE  
E
D
PO  
WE  
R
Coo  
Ene  
l
Sa  
r
gy  
er  
F
an  
Heat  
F
1
L
O
Timer  
TIM  
HIG  
H
W
MO  
DE  
TEMP  
'
ER  
S
P
A
N
EE  
D
PO  
WE  
R
Ventilate the room well when  
using this appliance together  
with a stove, etc.  
Turn off the power and breaker  
firstly when cleansing the unit.  
Turn off the main power switch  
when not using it for a long  
time.  
• An oxygen shortage may occur.  
• Since the fan rotates at high speed • Prevent accidental startup and the  
during operation, it may cause  
injury.  
possibility of injury.  
Coo  
Ene  
l
S
a
r
g
 e
y
F
r
an  
Hea  
t
F
1
 L
O
W
Timer  
TIM  
HIGH  
MO  
DE  
TM
'
F
ER  
SPF  
A
E
N
ED  
O  
W
ER  
Coo  
Ene  
l
Sa  
r
gy  
er  
an  
F
Hea  
t
F
1
L
O
Timer  
TIM  
HIG  
H
W
MO  
DE  
TEMP  
'
ER  
S
P
A
N
EE  
D
PO  
WE  
R
Cool  
Ene  
Sa  
r
gy  
er  
an  
v
F
Hea  
t
F
1
L
O
Timer  
TIM  
HIG  
H
W
MO  
DE  
TEMP  
'
F
ER  
SPF  
A
N
ED  
PO  
WE  
R
4 Room Air Conditioner  
Safety Precautions  
Do not operate or stop the unit  
by inserting or pulling out the  
power plug.  
Do not damage or use an  
unspecified power cord.  
Do not operate with wet hands  
or in damp environment.  
• It will cause electric shock or fire  
due to heat generation.  
• It will cause electric shock or fire.  
• It will cause electric shock.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F1  
L
O
GH  
F2  
 I
W
Tim  
er  
MO  
DE  
'
F
TIM  
ER  
TEM  
P
SPFAN  
EE  
D
PO  
WE  
R
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F1  
L
F2  
O
W
Tim  
er  
MO  
DE  
TEM  
'
F
TIM  
ER  
P
SPF  
A
NE  
E
D
PO  
WE  
R
Hold the plug by the head when  
taking it out.  
When gas leaks, open the win-  
dow for ventilation before oper-  
ating the unit.  
Never touch the metal parts of  
the unit when removing the fil-  
ter.  
• It may cause electric shock and  
damage.  
• Otherwise, it may cause explo-  
sion, and a fire.  
• They are sharp and may cause  
injury.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
an  
Hea  
F
t
F
1
L
O
2
HIG  
H
W
Tim  
MO  
er  
DE  
'
F
TIM  
TEMP  
ER  
SPF  
A
NE  
E
D
PO  
WE  
R
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F
2
L
O
W
Tim  
er  
MO  
DE  
TEM  
'
TIM  
ER  
P
SPF  
A
NE  
E
D
PO  
WE  
R
CAUTION  
I Installation  
Install the product so that the noise or hot wind  
from the outdoor unit may not cause any damage  
to the neighbors.  
Keep level parallel in installing the product.  
• Otherwise, it may cause dispute with the neighbors.  
• Otherwise, it may cause vibration or water leakage.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
F1  
at  
F
2
L
O
IGH  
W
Tim  
er  
MO  
'
F
DE  
TE  
TIM  
MP  
ER  
F
A
SP  
N
D
EE  
PO  
WE  
R
Service Manual 5  
Safety Precautions  
I Operation  
Do not put a pet or house plant  
where it will be exposed to  
direct air flow.  
Do not block the inlet or outlet  
of air flow.  
Use a soft cloth to clean. Do not  
use wax, thinner, or a strong  
detergent.  
• It may cause injury.  
• It may cause product failure.  
• The appearance of the air condi-  
tioner may deteriorate, change  
color, or develop surface flaws.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
a
F1  
F
2
H
O
 I
Tim  
er  
GH  
O  
E  
TEM  
T
ER  
P
PF  
D
P
E  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F
2
H
O
 I
W
Tim  
er  
GH  
MO  
DE  
TEM  
P
'
F
TIM  
ER  
Co  
S
PE  
FA  
N
ED  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
PO  
W
ER  
He  
at  
F1  
L
H
O
W
Tim  
er  
MO  
DE  
TEM  
P
'
F
TIM  
ER  
SPF  
A
N
ED  
PO  
WE  
R
Do not step on the indoor/out-  
door unit and do not put any-  
thing on it.  
Always insert the filter securely.  
Clean it every two weeks.  
Do not drink water drained from  
air conditioner.  
• It contains containments and will  
make you sick.  
• It may cause an injury through  
dropping of the unit or falling  
down.  
• Operation without filters will cause  
failure.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F1  
L
F2  
O
W
Tim  
er  
MO  
DE  
TEM  
'
F
TIM  
ER  
P
SPF  
A
NE  
E
D
PO  
WE  
R
Be cautious not to touch the  
sharp edges when installing.  
Avoid excessive cooling and  
perform ventilation sometimes.  
Do not insert the hands or bars  
through the air inlet or outlet  
during operation.  
• It may cause injury.  
• Otherwise, it may do harm to  
your health.  
• Otherwise, it may cause person-  
al injury.  
Co  
E
n
e
o
l
Sa  
r
gy  
er  
Fan  
He  
at  
F
2
L
O
W
Tim  
er  
MO  
DE  
Co  
o
l
TEM  
'
F
E
n
e
rgy  
TIM  
ER  
S
P
F
SPF  
A
NE  
H
E
eat  
F
D
HIG  
H
W
PO  
WE  
M
Time  
TIM  
OD  
r
R
E
'
F
TEM  
ER  
P
SPF  
A
NE  
E
D
PO  
WE  
R
Co  
E
n
o
l
S
e
r
g
y
v
e
r
n
He  
at  
F1  
F
2
H
O
W
Tim  
er  
IGH  
MO  
DE  
'
F
TE  
TIM  
M
ER  
P
F
A
SP  
N
EE  
D
PO  
W
E
6 Room Air Conditioner  
Operating Instructions  
Controls  
FAN SPEED  
Every time you push this button,it advances the setting as follows:{High[F2] Low[F1]} High[F2]  
REMOTE CONTROL SIGNAL  
RECEIVER  
TEMPERATURE SETTING  
Use this button to automatically control the  
temperature of the room  
The tmeperature can be set within a range of  
60 F to 86 F by increments of 1 F.  
The setting appears in the display.  
POWER  
To turn the air conditioner ON,push this button.  
To turn the air conditioner OFF,push the button  
again.  
TIMER  
SHUT-OFF TIME  
This button takes priority over any other button.  
You will usually use shut-off time while you sleep.  
If unit is running,use Timer to set number of hours until shut-off.  
For your sleeping comfortonce Timer is setthe Temperature  
setting will raise 2 F after 30 minand once again after another  
30 min.  
Push Timer button to advance setting from 1Hour→  
→12Hours maximum.  
2Hour →...  
START TIME  
If unit is off,use Timer to set number of hours before nuit starts.  
Push Timer button to advance setting from 1Hour→  
→12Hours maximum.  
2Hour →...  
MODE  
Push this button to shift mode of operation from COOL → MONEY SAVER→ FAN ONLY→HEAT  
COOL:  
Fan runs continually for normal cooling operation.  
MONEY SAVER:  
The fan stops when the compressor stops cooling.Approximately every 3 minutes the fan will turn on and the nuit will  
check the room air temperature to determine if cooling is needed.  
FAN ONLY:  
Fan-only operation.  
HEAT:  
Fan runs continually for normal heating operation.  
AUTO RESTART  
When power is restored after an electrical power failure,the unit will begin to run at its last setting.  
7 Room Air Conditioner  
REMOTE CONTROL  
POWER  
To turn the air conditioner ON,push this button.  
To turn the air conditioner OFF,push the button again.  
This button takes priority over any other button.  
TEMPERATURE SETTING  
Use this button to automatically control the temperature of the room.  
The tmeperature can be set within a range of  
increments of 1 F.  
60 F to 86 F by  
The setting appears in the display.  
FAN SPEED  
Every time you push this button,it advances the setting as follows:  
Low[F1]} High[F2]  
{High[F2]  
TIMER  
SHUT-OFF TIME  
You will usually use shut-off time while you sleep.  
If unit is running,use Timer to set number of hours until shut-off.  
setting will  
For your sleeping comfortonce Timer is setthe Temperature  
raise 2 F after 30 minand once again after another  
30 min.  
Push Timer button to advance setting from 1Hour→  
→12Hours maximum.  
2Hour →...  
START TIME  
If unit is off,use Timer to set number of hours before nuit starts.  
Push Timer button to advance setting from 1Hour→  
→12Hours maximum.  
2Hour →...  
MODE  
Push this button to shift mode of operation from COOL → MONEY SAVER→ FAN ONLY→HEAT  
COOL:  
Fan runs continually for normal cooling operation.  
MONEY SAVER:  
The fan stops when the compressor stops cooling.Approximately every 3 minutes the fan will turn on and the nuit will  
check the room air temperature to determine if cooling is needed.  
FAN ONLY:  
Fan-only operation.  
HEAT:  
Fan runs continually for normal heating operation.  
CAUTION  
A slight heat odor may come from the nuit  
When the air conditioner has been performed its  
when first switching to HEAT after the  
cooling or feating operation and is turned off or  
cooling season is over.This odor,caused  
set to the fan positionwait at 3 minutes  
by fine duct particles on the heater,will  
before resetting to the cooling operation again.  
disappear quickly.This is harmless.  
Service Manual 8  
Disassembly Instructions  
Disassembly Instructions  
Before the following disassembly, POWER SWITCH is set to OFF and disconnected the power cord.  
Mechanical Parts  
1. FRONT GRILLE  
1. Open the inlet grille upward or downward.  
'
F
LO  
G
H
W
F1 HI  
F2  
ol  
P
EM  
Co  
r
T
ER  
gy  
W
E
ne er  
S
av  
PO  
e
r
an  
Tim  
N
A
D
F
F
EE  
SP  
t
H
ea  
TIMER  
DE  
MO  
2. Remove the screw which fastens the front grille.  
3. Pull the front grille from the right side.  
4. Remove the front grille. (See Fig. 1)  
5. Re-install the component by referring to the  
removal procedure.  
Cool  
F
1
L
O
W
'
F
F
2
H
I
G
H
Energy  
Saver  
Fan  
TEMP  
Heat  
Timer  
F
AN  
MODE  
TIMER  
POWER  
SPEED  
FIG. 1  
2. CABINET  
1. After disassembling the FRONT GRILLE, remove the 9  
screws which fasten the cabinet at the both sides and the  
top. (See Fig. 2)  
C
o
o
l
E
S
ne  
rg  
y
av  
er  
Keep these for later use.  
F
an  
F1  
F2  
LO  
W
ME  
F3  
D
HI  
GH  
T
'
im  
F
er  
M
O
T
D
E
E
M
P
T
IM  
E
R
F
A
S
N
PEED  
P
O
W
E
R
3. CONTROL BOX  
FIG. 2  
1. Remove the front grille. (Refer to section 1)  
2. Remove the screw which fasten the control  
box. (See Fig. 3)  
3. Pull the control box from the barrier.(See Fig.3)  
4. Discharge the capacitor by placing a 20,000 ohm resistor  
across the capacitor terminals.  
Cool  
Ener  
gy  
Sa  
ver  
Fa  
n
F1  
F2  
LO  
W
M
F3  
E
D
H
IG  
H
Timer  
IM  
'
F
M
O
T
D
E
E
M
P
T
E
R
F
A
N
S
P
E
E
D
P
O
W
E
R
5. Disconnect two wire housings in the control box.  
6. Pull the control box forward completely.  
7. Re-install the components by referring to the removal  
procedure. (See Fig. 3)  
(Refer to the circuit diagram found on pages 24 in this  
manual and on the control box.)  
FIG. 3  
Service Manual 9  
Disassembly Instructions  
Air Handling Parts  
4. ORIFICE, HEATER ASSY AND TURBO FAN  
1. Remove the front grille. (Refer to section 1)  
2. Remove the cabinet. (Refer to section 2)  
3. Remove the 2 screws which fasten the evaporator  
at the left side and the right side.  
(See Fig. 4)  
C
e
o
o
l
E
S
n
a
rg  
e
y
r
v
F
a
n
F1  
F2  
LO  
W
M
F
3
E
D
HI  
GH  
T
'
im  
F
e
r
MODE  
T
E
M
P
TI  
MER  
F
A
S
N
P
E
E
D
P
O
W
E
R
4. Move the evaporator sideward carefully.  
5. Remove the 2 terminals carefully  
(See Fig. 28, at Electric Heater Model only)  
FIG. 4  
6. Remove the 4 screws which fasten the orifice. (See  
Fig. 5)  
7. Remove the orifice. (See Fig. 5)  
FIG. 5  
8. Remove the clamp which secures the turbo fan with  
plier. (See Fig. 6)  
FIG. 6  
9. Remove the turbo fan with plier or your hand with-  
out touching blades. (See Fig. 7)  
10. Re-install the components by referring to the  
removal procedure, above.  
5. FAN  
FIG. 7  
1. Remove the cabinet. (Refer to section 2)  
2. Remove the brace and shroud cover.  
(Refer to section 4)  
3. Remove the 6 screws which fasten the condenser.  
4. Move the condenser sideways carefully.  
5. Remove the clamp which secures the fan.  
6. Remove the fan. (See Fig. 8)  
7. Re-install the components by referring to the removal  
procedure, above.  
FIG. 8  
10 Room Air Conditioner  
Disassembly Instructions  
6. SHROUD  
1. Remove the fan. (Refer to section 5)  
2. Remove the screw which fasten the shroud.  
3. Remove the shroud. (See Fig. 9)  
4. Re-install the component by referring to the  
removal procedure, above.  
FIG. 9  
Electrical Parts  
7. MOTOR  
1. Remove the cabinet. (Refer to section 2)  
2. Remove the clamp cord and disconnect a wire  
housing in control box. (Refer to section 3)  
3. Remove the turbo fan. (Refer to section 5)  
4. Remove the fan. (Refer to section 5)  
5. Remove the 4 or 2 screws which fasten the motor.  
(See Fig. 10)  
6. Remove the motor.  
7. Re-install the components by referring to the  
removal procedure, above.  
FIG. 10  
8. COMPRESSOR  
1. Remove the cabinet. (Refer to section 2)  
2. Discharge the refrigerant system using FreonTM  
Recovery System.  
If there is no valve to attach the recovery system,  
install one (such as a WATCO A-1) before venting  
the FreonTM . Leave the valve in place after  
servicing the system.  
3. Disconnect the 3 leads from the compressor.  
4. After purging the unit completely, unbraze the suc-  
tion and discharge tubes at the compressor con-  
nections.  
FIG. 11  
5. Remove the 3 nuts and the 3 washers which fas-  
ten the compressor. (See Fig. 11)  
6. Remove the compressor.  
7. Re-instill the components by referring to the  
removal procedure, above.  
9. CAPACITOR  
Cool  
Ener  
gy  
Sa  
ver  
Fa  
n
F1 LO  
F2  
M
W
H
F
ED  
3
HIG  
Timer  
'
F
1. Remove the control box. (Refer to section 3)  
2. Remove a screw which fasten the display panel.  
3. Remove 2 screws and unfold the control box.  
(See Fig. 12)  
MODE  
TEM  
P
TIMER  
FA  
N
SPEED  
PO  
WER  
4. Remove the screw and the clamp which fastens  
the capacitor. (See Fig. 12)  
5. Disconnect all the leads of capacitor terminals.  
6. Re-install the components by referring to the  
removal procedure, above.  
FIG. 12  
Service Manual 11  
Disassembly Instructions  
10. POWER CORD  
1. Remove the control box. (Refer to section 3)  
2. Unfold the control box. (Refer to section 9)  
3. Disconnect the grounding screw from the control  
box.  
4. Disconnect 2 receptacles.  
5. Remove a screw which fastens the clip cord.  
6. Pull the power cord. (See Fig. 13)  
Cool  
Ener  
gy  
Sa  
ver  
Fa  
n
F
1
L
O
ED  
F
W
2
M
F
3
H
IG  
H
Timer  
'
F
MODE  
TEMP  
7. Re-install the component by referring to the  
removal procedure, above.  
TIMER  
FA  
N
SPEED  
PO  
WER  
(Use only one ground-marked hole  
connection.)  
for ground  
8. If the supply cord of this appliance is damaged, it  
must be replaced by the special cord.  
(The special cord means the cord which has the  
same specification marked on the supply cord fit-  
ted to the unit.)  
FIG. 13  
11. THERMOSTAT  
1. Remove the control box. (Refer to section 3)  
2. Unfold the control box. (Refer to section 9)  
Cool  
Ener  
Sa  
gy  
ver  
Fa  
n
F
1
L
O
W
E
D
H
F
2
M
F
3
3. Disconnect the theristor terminals from main  
P.W.B assembly.  
H
IG  
Timer  
'
F
MODE  
TEMP  
FA  
N
SPEED  
PO  
WER  
4. Remove the thermostat. (See Fig. 14)  
5. Re-install the components by referring to the  
removal procedure, above.  
FIG. 14  
12 Room Air Conditioner  
Disassembly Instructions  
Refrigerating Cycle  
CAUTION  
TM  
Discharge the refrigerant system using Freon  
Recovery System.  
If there is no valve to attach the recovery system,  
install one (such as a WATCO A-1) before vent-  
TM  
ing the Freon . Leave the valve in place after  
servicing the system.  
12. CONDENSER  
1. Remove the cabinet. (Refer to section 2)  
2. Remove the brace and the shroud cover.  
(Refer to section 4)  
3. Remove the 5 screws which fasten the condenser.  
4. After discharging the refrigerant completely,  
unbraze the interconnecting tube at the condenser  
connections.  
FIG. 15  
5. Remove the condenser.  
6. Re-install the components by referring to notes.  
(See Fig. 15)  
13. EVAPORATOR  
1. Remove the cabinet. (Refer to section 2)  
2. Discharge the refrigerant completely.  
3. Remove the 2 screws which fasten the evaporator  
at the left side and the right side.  
Cool  
Ener  
gy  
Sa  
ver  
Fa  
n
F1  
L
F
2
M
O
W
F3 ED  
HIG  
H
Timer  
IM  
'
F
M
O
T
D
E
E
M
P
T
E
R
F
A
S
N
P
E
E
D
P
O
W
E
R
4. Move the evaporator sideward carefully and then  
unbraze the interconnecting tube at the evaporator  
connectors.  
5. Remove the evaporator.  
6. Re-install the components by referring to notes.  
(See Fig. 16)  
FIG. 16  
14. CAPILLARY TUBE  
1. Remove the cabinet. (Refer to section 2)  
2. After discharging the refrigerant completely,  
unbraze the interconnecting tube at the capillary  
tube.  
3. Remove the capillary tube.  
4. Re-install the components by referring to notes.  
Service Manual 13  
Disassembly Instructions  
NOTICE  
Replacement of the refrigeration cycle.  
6. Recharge as follows :  
1. When replacing the refrigeration cycle, be sure to  
discharge the refrigerant system using a FreonTM  
recovery System.  
1) Refrigeration cycle systems are charged from the  
High-side. If the total charge cannot be put  
in the High-side, the balance will be put in the  
suction line through the access valve which you  
installed as the system was opened.  
2) Connect the charging cylinder as shown in Fig. 17B.  
With valve C open, discharge the hose at the man-  
ifold connection.  
3) Open valve A and allow the proper charge to  
enter the system. Valve B is still closed.  
4) If more charge is required, the high-side will not  
take it. Close valve A.  
5) With the unit running, open valve B and add the  
balance of the charge.  
If there is no valve to attach the recovery system,  
install one (such as a WATCO A-1) before venting  
the FreonTM. Leave the valve in place after  
servicing the system.  
2. After discharging the unit completely, remove the  
desired component, and unbrace the pinch-off  
tubes.  
3. Solder service valves into the pinch-off tube ports,  
leaving the valves open.  
4. Solder the pinch-off tubes with Service valves.  
5. Evacuate as follows.  
1) Connect the vacuum pump, as illustrated Fig.  
17A.  
2) Start the vacuum pump, slowly open manifold  
valves A and B with two full turns counterclock-  
wise and leave the valves closed.  
a. Do not add the liquid refrigerant to the Low-  
side.  
b. Watch the Low-side gauge; allow pressure to  
rise to 39 lbs.  
c. Turn off valve B and allow pressure to drop.  
d. Repeat steps B and C until the balance of the  
charge is in the system.  
The vacuum pump is now pulling through valves  
A and B up to valve C by means of the manifold  
and entire system.  
6) When satisfied the unit is operating correctly,  
use the pinch-off tool with the unit still running  
and clamp on to the pinch-off tube. Using a tube  
cutter, cut the pinch-off tube about 2 inches from  
the pinch-off tool. Use sil-fos solder and solder  
pinch-off tube closed. Turn off the unit, allow it to  
set for a while, and then test the leakage of the  
pinch-off connection.  
CAUTION  
If high vacuum equipment is used, just crack  
valves A and B for a few minutes, then open  
slowly with the two full turns counterclockwise.  
This will keep oil from foaming and being  
drawn into the vacuum pump.  
3) Operate the vacuum pump for 20 to 30 minutes,  
until 600 microns of vacuum is obtained. Close  
valves A and B, and observe vacuum gauge for  
a few minutes. A rise in pressure would  
indicate a possible leak or moisture remaining in  
the system. With valves A and B closed, stop  
the vacuum pump.  
4) Remove the hose from the vacuum pump and  
place it on the charging cylinder. See Fig. 17B.  
Open valve C.  
Discharge the line at the manifold connection.  
5) The system is now ready for final charging.  
14 Room Air Conditioner  
Disassembly Instructions  
Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool capa-  
ble of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.  
COMPOUND GAUGE  
CONDENSER  
(HIGH PRESSURE SIDE)  
MANIFOLD  
GAUGE  
A
B
CAPILLARY TUBE  
SEE INSETS  
BELOW  
EVAPORATOR  
(LOW PRESSURE SIDE)  
COMPRESSOR  
HI  
LOW  
A
B
A
B
EXTERNAL  
VACUUM PUMP  
CHARGING  
CYLINDER  
C
FIG. 17A-Pulling Vacuum  
FIG 17B-Charging  
Service Manual 15  
Schematic Diagram  
Schematic Diagram  
Wiring Diagram  
I ELECTRIC HEATING MODEL  
16 Room Air Conditioner  
Troubleshooting Guide  
Troubleshooting Guide  
Piping System  
CONDENSER COILS  
FAN  
CAPILLARY TUBE  
COMPRESSOR  
MOTOR  
TURBO FAN  
EVAPORATOR COILS  
: REFRIGERANT FLOW  
Following is a brief description of the important components and their functions in the refrigeration system.  
Refer to Fig. 18 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle.  
ROOM AIR CONDITIONER  
CYCLE OF REFRIGERATION  
EVAPORATOR COILS  
CONDENSER COILS  
VAPOR INLET  
SUCTION LIME  
COOL LOW PRESSURE VAPOR  
HOT  
DISCHARGED  
AIR  
COMPLETE LIQUID  
BOIL OFF POINT  
COOLED  
AIR  
ROOM AIR HEAT LOAD  
OUTSIDE COOLING  
AIR FOR REFRIGERANT  
PASS THROUGH  
MOTOR  
COMPRESSOR  
OIL  
LIQUID  
PRESSURE  
DROP  
LIQUID OUTLET  
HIGH PRESSURE VAPOR  
(LIQUID REFRIGERANT)  
LIQUID PEFRIGERANT  
CAPILLARY TUBE  
LOW PRESSURE VAPOR  
FIG. 18  
Service Manual 17  
Troubleshooting Guide  
Troubleshooting Guide  
In general, possible trouble is classified in two causes.  
The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air  
Conditioning caused by a defect in the refrigeration circuit and improper application.  
Unit is running but cooling is ineffective  
Ineffective Cooling  
Check of cold air circulation  
for smooth flow.  
Check of outdoor coil  
(heat exchanger) & the fan  
operation.  
Check heat load increase.  
Unexpected residue  
Overloaded Circuit  
Dirty indoor coil  
(Heat exchanger)  
Check gas leakage.  
Repair gas leak.  
Malfunction of fan  
Check of inside gas  
pressure.  
Clogged of air filter  
Obstruction at air outlet  
Replacement of unit if the  
unit is beyond repair.  
Adjusting of refrigerant  
charge  
Stop of auto air-swing  
Correct above trouble  
Malfunction of compressor  
Replacement of  
compressor  
Check clogging in  
refrigeration circuit.  
Satisfactory operation with  
temperature difference of  
inlet & outlet air ; 44.6~50˚F  
Repair clogging in  
refrigeration circuit.  
18 Room Air Conditioner  
Troubleshooting Guide  
Fails to Start  
Check of power source.  
Check of circuit breaker  
and fuse.  
Check of control switch  
setting.  
Gas leakage of feeler bulb  
of thermostat  
Check of control switch.  
Only compressor fails to  
start.  
Only fan fails to start.  
Improper wiring.  
Drop of power voltage.  
Improper thermostat setting  
Defect of fan motor  
capacitor.  
Defect of compressor  
capacitor.  
Loose terminal connection.  
Improper wiring  
Irregular motor resistance  
(
).  
Irregular motor insulation  
).  
Check capacitor.  
Replacement.  
(
Replacement of fan motor  
Regular but fails to start  
Irregular motor resistance ( )  
Irregular motor insulation ( )  
Replacement of compressor  
(locking of rotor, metal)  
Replacement of compressor  
(Motor damaged)  
Service Manual 19  
Troubleshooting Guide  
COMPLAINT  
CAUSE  
REMEDY  
Fan motor will not run.  
No power  
Check voltage at outlet. Correct if none.  
Wire disconnected or  
connection loose  
Connect wire. Refer to wiring diagram for terminal  
identification. Repair or replace loose terminal.  
Capacitor (Discharge  
Test capacitor.  
capacitor before testing.)  
Replace if not within ±10% of manufacturer's  
rating. Replace if shorted, open, or damaged.  
Fan blade hitting shroud or blower wheel hitting  
scroll. Realign assembly.  
Will not rotate  
Units using slinger ring condenser fans must  
have 1/4 to 5/16 inch clearance to the base. If it is  
hitting the base, shim up the bottom of the fan  
motor with mounting screw(s).  
Check fan motor bearings; if motor shaft will not  
rotate, replace the motor.  
Fan motor runs  
intermittently  
Revolves on overload.  
Check voltage. See limits on this page. If not within  
limits, call an electrician.  
Test capacitor.  
Check bearings. Does the fan blade rotate freely?  
If not, replace fan motor.  
Pay attention to any change from high speed to  
low speed. If the speed does not change, replace  
the motor.  
Fan motor noise.  
Grommets  
Fan  
Check grommets; if worn or missing, replace them.  
If cracked, out of balance, or partially missing,  
replace it.  
Turbo fan  
If cracked, out of balance, or partially missing,  
replace it.  
Loose set screw  
Worn bearings  
Tighten it.  
If knocking sounds continue when running or  
loose, replace the motor. If the motor hums or  
noise appears to be internal while running,  
replace motor.  
20 Room Air Conditioner  
Troubleshooting Guide  
REMEDY  
COMPLAINT  
CAUSE  
Compressor will not run,  
but fan motor runs.  
Voltage  
Wiring  
Check voltage. See the limits on the preceding.  
page. If not within limits, call an electrician.  
Check the wire connections, if loose, repair or  
replace the terminal. If wires are off, refer to wiring  
diagram for identification, and replace. Check wire  
locations. If not per wiring diagram, correct.  
Check the capacitor.  
Replace if not within ±10% of manufacturers  
rating. Replace if shorted, open, or damaged.  
Capacitor (Discharge  
capacitor before  
servicing.)  
Check the compressor for open circuit or  
ground. If open or grounded, replace the compres-  
sor.  
Compressor  
Overload  
Check the compressor overload, if externally  
mounted. Replace if open. (If the compressor  
temperature is high, remove the overload, cool it,  
and retest.)  
ROOM AIR CONDITIONER VOLTAGE LIMITS  
NAME PLATE RATING  
MINIMUM  
MAXIMUM  
126.5V  
253V  
115V  
103.5V  
187V  
208/230V  
Service Manual 21  
Troubleshooting Guide  
REMEDY  
COMPLAINT  
CAUSE  
Compressor cycles  
on overload.  
Voltage  
Check the voltage. See the limits on the preced-  
ing page. If not within limits, call an electrician.  
Overload  
Check overload, if externally mounted.  
Replace if open. (If the compressor temperature  
is high, remove the overload, cool, and retest.)  
Fan motor  
If not running, determine the cause. Replace if  
required.  
Condenser air flow  
restriction  
Remove the cabinet. inspect the interior surface  
of the condenser; if restricted, clean carefully  
with a vacuum cleaner (do not damage fins) or  
brush. Clean the interior base before  
reassembling.  
Condenser fins  
(damaged)  
If condenser fins are closed over a large area  
on the coil surface, head pressures will increase,  
causing the compressor to cycle. Straighten the  
fins or replace the coil.  
Capacitor  
Test capacitor.  
Wiring  
Refrigerating system  
Insufficient cooling or heat- Air filter  
Check the terminals. If loose, repair or replace.  
Check the system for a restriction.  
If restricted, clean of replace.  
ing  
Exhaust damper door  
Close if open.  
Unit undersized  
Blower or fan  
Determine if the unit is properly sized for the area to  
be cooled.  
Excessive noise.  
Check the set screw or clamp. If loose or missing,  
correct. If the blower or fan is hitting air guide,  
rearrange the air handling parts.  
Remove the cabinet and carefully rearrange tubing  
not to contact cabinet, compressor, shroud, and bar-  
rier.  
Copper tubing  
22 Room Air Conditioner  
Product Specifications  
MODELS  
UE08C13  
REMARK  
ITEMS  
1Ø,115V,60HZ  
POWER SUPPLY  
CAPACITY(Btu/h)  
INPUT(W)  
8,000  
830  
7.5  
COOLING  
RUNNING CURRENT(A)  
E.E.R(Btu/W.h)  
9.6  
CAPACITY(Btu/h)  
INPUT(W)  
3,850  
1,230  
10.7  
HEATING  
RUNNING CURRENT(A)  
80  
95  
70  
47  
67  
(DB)  
(WB)  
(WB)  
INDOOR(°F)  
COOLING  
HEATING  
OUTDOOR(°F)  
(DB) 75  
OPERATING  
TEMPERATURE  
)
INDOOR(°F)  
(
(
60  
(DB)  
(DB)  
WB  
OUTDOOR(°F)  
)
44  
WB  
REFRIGERANT(R410A)  
EVAPORATOR  
CHARGE(g  
320  
(11.3OZ)  
2 ROW 12 STACKS  
Ø5.0 3 ROW 18 STACKS,L-BENDED TYPE  
TURBO FAN  
LOUVER-  
FIN TYPE  
CONDENSER  
FAN,INDOOR  
PROPELLER TYPE FAN WITH SLINGER-RING  
2/2/2  
FAN,OUTDOOR  
(FAN/COOLING/HEATING)  
FAN,SPEEDS  
FAN,MOTOR  
6 POLES  
TOUCH PANEL  
OPERATION CONTROL  
ROOM TEMP.CONTROL  
THERMISTOR  
VERTICAL LOUVER (RIGHT&LEFT)  
AIR DIRECTTION CONTROL  
HORIZONTAL LOUVER (UP&DOWN)  
TOP - DOWN  
CONSTRUCTION  
3.5KW,230V  
ELECTRIC HEATER  
COMPRESSOR  
EXTERNAL OVERLOAD PROTECTOR  
INTERANL THERMAL PROTECTOR  
PROTECTOR  
FAN,MOTOR  
ELECTRIC HEATER  
FUSE LINK,BIMETAL THERMOSTAT  
1.92m3WIRE WITH GROUDING)  
POWER CORD  
DRAIN SYSTEM  
ATTACHMENT PLUG(CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
80/36  
NET WEIGHT(lbs/kg)  
24 21/32 x 14 13/32 x 19 21/32  
656 x 366 x 499  
DIMENSION  
(Wx Hx D)  
( inch)  
( mm)  
( inch)  
(mm)  
25 7/8 x 15 17/32 x 16 23/32  
SLEEVE DIMESION  
(Wx Hx D)  
OPTIONA PART  
656 x 394 x 425  
SLEEVE DEPTH  
( inch)  
(mm)  
20  
510  
WITH FRONT GRILLE  
Service Manual 23  
Product Specifications  
MODELS  
UE10C33  
REMARK  
ITEMS  
1Ø,230/208V,60HZ  
POWER SUPPLY  
CAPACITY(Btu/h)  
INPUT(W)  
10 000/9 800  
1,080/1 040  
4.7/5.2  
COOLING  
RUNNING CURRENT(A)  
E.E.R(Btu/W.h)  
9.4/9.4  
11 200/9 200  
3,500/2 900  
15.3/14.0  
CAPACITY(Btu/h)  
INPUT(W)  
HEATING  
RUNNING CURRENT(A)  
80  
95  
70  
47  
67  
(WB)  
(DB)  
INDOOR(°F)  
COOLING  
HEATING  
(DB) 75 (WB)  
OUTDOOR(°F)  
OPERATING  
TEMPERATURE  
(
(
)
60  
(DB)  
(DB)  
WB  
INDOOR(°F)  
OUTDOOR(°F)  
)
44  
WB  
REFRIGERANT(R410A)  
EVAPORATOR  
CHARGE(g  
440  
(15.5OZ)  
3 ROW 12 STACKS  
2 ROW 18 STACKS,L-BENDED TYPE 1 ROW  
TURBO FAN  
LOUVER-  
FIN TYPE  
CONDENSER  
FAN,INDOOR  
PROPELLER TYPE FAN WITH SLINGER-RING  
2/2/2  
FAN,OUTDOOR  
(FAN/COOLING/HEATING)  
FAN,SPEEDS  
FAN,MOTOR  
6 POLES  
TOUCH PANEL  
OPERATION CONTROL  
ROOM TEMP.CONTROL  
THERMISTOR  
VERTICAL LOUVER (RIGHT&LEFT)  
AIR DIRECTTION CONTROL  
HORIZONTAL LOUVER (UP&DOWN)  
TOP - DOWN  
CONSTRUCTION  
3.5KW,230V  
ELECTRIC HEATER  
COMPRESSOR  
EXTERNAL OVERLOAD PROTECTOR  
INTERANL THERMAL PROTECTOR  
PROTECTOR  
FAN,MOTOR  
ELECTRIC HEATER  
FUSE LINK,BIMETAL THERMOSTAT  
1.92m3WIRE WITH GROUDING)  
POWER CORD  
DRAIN SYSTEM  
ATTACHMENT PLUG(CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
80/36  
NET WEIGHT(lbs/kg)  
24 21/32 x 14 13/32 x 19 21/32  
656 x 366 x 499  
DIMENSION  
(Wx Hx D)  
( inch)  
( mm)  
( inch)  
(mm)  
25 7/8 x 15 17/32 x 16 23/32  
SLEEVE DIMESION  
(Wx Hx D)  
OPTIONA PART  
656 x 394 x 425  
SLEEVE DEPTH  
( inch)  
(mm)  
20  
510  
WITH FRONT GRILLE  
24 Room Air Conditioner  
Product Specifications  
MODELS  
UE12C13  
REMARK  
ITEMS  
1Ø,230/208V,60HZ  
POWER SUPPLY  
CAPACITY(Btu/h)  
INPUT(W)  
11 500/11,200  
1,220/1 190  
5.6/6.0  
COOLING  
RUNNING CURRENT(A)  
E.E.R(Btu/W.h)  
9.4/9.4  
11 200/9 200  
3,500/2 900  
15.3/14.0  
CAPACITY(Btu/h)  
INPUT(W)  
HEATING  
RUNNING CURRENT(A)  
80  
95  
70  
47  
67  
(WB)  
(DB)  
INDOOR(°F)  
COOLING  
HEATING  
(DB) 75 (WB)  
OUTDOOR(°F)  
OPERATING  
TEMPERATURE  
(
(
)
60  
(DB)  
(DB)  
WB  
INDOOR(°F)  
)
OUTDOOR(°F)  
44  
WB  
REFRIGERANT(R410A)  
EVAPORATOR  
CHARGE(g  
540  
(19.0OZ)  
3 ROW 12 STACKS  
2 ROW 18 STACKS,L-BENDED TYPE 1 ROW  
TURBO FAN  
LOUVER-  
FIN TYPE  
CONDENSER  
FAN,INDOOR  
PROPELLER TYPE FAN WITH SLINGER-RING  
2/2/2  
FAN,OUTDOOR  
(FAN/COOLING/HEATING)  
FAN,SPEEDS  
FAN,MOTOR  
6 POLES  
TOUCH PANEL  
OPERATION CONTROL  
ROOM TEMP.CONTROL  
THERMISTOR  
VERTICAL LOUVER (RIGHT&LEFT)  
AIR DIRECTTION CONTROL  
HORIZONTAL LOUVER (UP&DOWN)  
TOP - DOWN  
CONSTRUCTION  
3.5KW,230V  
ELECTRIC HEATER  
COMPRESSOR  
EXTERNAL OVERLOAD PROTECTOR  
INTERANL THERMAL PROTECTOR  
PROTECTOR  
FAN,MOTOR  
ELECTRIC HEATER  
FUSE LINK,BIMETAL THERMOSTAT  
1.92m3WIRE WITH GROUDING)  
POWER CORD  
DRAIN SYSTEM  
ATTACHMENT PLUG(CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
80/36  
NET WEIGHT(lbs/kg)  
24 21/32 x 14 13/32 x 19 21/32  
656 x 366 x 499  
DIMENSION  
(Wx Hx D)  
( inch)  
( mm)  
( inch)  
(mm)  
25 7/8 x 15 17/32 x 16 23/32  
SLEEVE DIMESION  
(Wx Hx D)  
OPTIONA PART  
656 x 394 x 425  
SLEEVE DEPTH  
( inch)  
(mm)  
20  
510  
WITH FRONT GRILLE  
Service Manual 25  
Exploded View  
Exploded View  
130900  
135312  
C
147582-1  
145200  
147581  
147582-2  
435301  
435300  
152302  
135313  
132100  
731273  
352380  
D
559011  
349001  
349480  
148000  
W48602  
E
753000  
149980  
346811  
130410  
359012  
349600  
267110  
W48602  
552206  
A
567480  
268711-2  
249950  
249940  
238310  
268711-1  
B
C
oo  
l
E
S
ne  
r
g
y
r
a
v
e
F
an  
F
2
3
1
L
F
O
W
D
H
M
H
F
E
IG  
T
ime  
'
F
r
M
O
D
T
E
E
M
P
T
567502  
IM  
ER  
F
E
A
E
N
S
P
D
P
O
W
ER  
237200  
264110  
550140  
W0CZZ  
26 Room Air Conditioner  
LocNo  
Description  
UE08C13  
W0CZZ  
130410  
130900  
132100  
135303  
135312  
238310  
W48602  
346811  
147581  
147582-1  
147582-2  
349600  
149980  
550140  
152302  
352380  
359012  
559011  
567480  
264110  
267110  
567502  
268711-2  
268711-1  
435300  
237200  
731273  
249950  
435301  
349480  
753000  
CAPACITOR,FILM,BOX  
BASE ASSEMBLY,SINGLE  
CABINET  
67301909  
67302923  
67303718  
67303504  
67306113  
67306020  
67304802  
67302500  
67303019  
67306203  
67306252  
67306253  
67303607  
67303111  
67305000  
67304304  
67302735  
67302608  
67303202  
67307808  
67300031  
67302239  
67301907  
67307644  
67307646  
67307208  
67305527  
67306307  
67305528  
67304801  
67303406  
67310101  
FRAME  
GRILLE,INLET  
GRILLE ASSEMBLY,FRONT(SINGLE)  
ESCUTCHEON  
CLAMP,SPRING  
MOTOR ASSEMBLY,SINGLE  
LOUVER,HORIZONTAL  
LOUVER,VERTICAL  
LOUVER,VERTICAL  
BRACKET,MOTOR  
SHROUD  
DAMPER,COMPRESSOR  
FILTER,AIR  
AIR GUIDE  
FAN,TURBO  
FAN ASSEMBLY,AXIAL  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
REMOTE CONTROLLER ASSEMBLY  
OverloadProtect  
PWB(PCB) ASSEMBLY,MAIN  
PWB(PCB) ASSEMBLY,DISPLAY  
PLASTIC REAR AIR DEFLECTOR  
PANEL,CONTROL  
INSTALL PART ASSEMBLY,SINGLE  
CASE ASSEMBLY,CONTROL  
GRILLE,REAR  
ORIFICE  
Heater,Electric  
Service Manual 27  
LocNo  
Description  
UE10C33  
W0CZZ  
130410  
130900  
132100  
135303  
135312  
238310  
W48602  
346811  
147581  
147582-1  
147582-2  
349600  
149980  
550140  
152302  
352380  
359012  
559011  
567480  
264110  
267110  
567502  
268711-2  
268711-1  
435300  
237200  
731273  
249950  
435301  
349480  
753000  
CAPACITOR,FILM,BOX  
BASE ASSEMBLY,SINGLE  
CABINET  
67301910  
67302923  
67303718  
67303504  
67306104  
67306005  
67304802  
67302500  
67303008  
67306203  
67306252  
67306253  
67303607  
67303111  
67305000  
67304304  
67302735  
67302608  
67303202  
67307808  
67300029  
67302239  
67301908  
67307645  
67307646  
67307208  
67305527  
67306307  
67305529  
67304801  
67303406  
67310100  
FRAME  
GRILLE,INLET  
GRILLE ASSEMBLY,FRONT(SINGLE)  
ESCUTCHEON  
CLAMP,SPRING  
MOTOR ASSEMBLY,SINGLE  
LOUVER,HORIZONTAL  
LOUVER,VERTICAL  
LOUVER,VERTICAL  
BRACKET,MOTOR  
SHROUD  
DAMPER,COMPRESSOR  
FILTER,AIR  
AIR GUIDE  
FAN,TURBO  
FAN ASSEMBLY,AXIAL  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
REMOTE CONTROLLER ASSEMBLY  
OverloadProtect  
PWB(PCB) ASSEMBLY,MAIN  
PWB(PCB) ASSEMBLY,DISPLAY  
PLASTIC REAR AIR DEFLECTOR  
PANEL,CONTROL  
INSTALL PART ASSEMBLY,SINGLE  
CASE ASSEMBLY,CONTROL  
GRILLE,REAR  
ORIFICE  
Heater,Electric  
28 Room Air Conditioner  
LocNo  
Description  
UE12C33  
W0CZZ  
130410  
130900  
132100  
135303  
135312  
238310  
W48602  
346811  
147581  
147582-1  
147582-2  
349600  
149980  
550140  
152302  
352380  
359012  
559011  
567480  
264110  
267110  
567502  
268711-2  
268711-1  
435300  
237200  
731273  
249950  
435301  
349480  
753000  
CAPACITOR,FILM,BOX  
BASE ASSEMBLY,SINGLE  
CABINET  
67301911  
67302930  
67303718  
67303504  
67306104  
67306005  
67304802  
67302500  
67303020  
67306203  
67306252  
67306253  
67303606  
67303111  
67305000  
67304304  
67302735  
67302608  
67303202  
67307808  
67300029  
67302239  
67301906  
67307645  
67307646  
67307208  
67305527  
67306307  
67305530  
67304801  
67303406  
67310100  
FRAME  
GRILLE,INLET  
GRILLE ASSEMBLY,FRONT(SINGLE)  
ESCUTCHEON  
CLAMP,SPRING  
MOTOR ASSEMBLY,SINGLE  
LOUVER,HORIZONTAL  
LOUVER,VERTICAL  
LOUVER,VERTICAL  
BRACKET,MOTOR  
SHROUD  
DAMPER,COMPRESSOR  
FILTER,AIR  
AIR GUIDE  
FAN,TURBO  
FAN ASSEMBLY,AXIAL  
THERMISTOR ASSEMBLY  
POWER CORD ASSEMBLY  
REMOTE CONTROLLER ASSEMBLY  
OverloadProtect  
PWB(PCB) ASSEMBLY,MAIN  
PWB(PCB) ASSEMBLY,DISPLAY  
PLASTIC REAR AIR DEFLECTOR  
PANEL,CONTROL  
INSTALL PART ASSEMBLY,SINGLE  
CASE ASSEMBLY,CONTROL  
GRILLE,REAR  
ORIFICE  
Heater,Electric  
Service Manual 29  
FRIEDRICH AIR CONDITIONING CO.  
Post Office Box 1540 4200 N. Pan Am Expressway San Antonio, Texas 78295-1540  
(210) 357-4400 FAX (210) 357-4480  
Printed in the U.S.A  
Unifit Heat Cool Svc Parts 2010 (05/10)  

Actron Compression Tester CP7821 User Manual
Admiral AAW 12CM1FHUE User Manual
Briggs Stratton Automobile Parts 350000 User Manual
Brodit Molex Active Holder User Manual
Brother MFC 5440CN User Manual
Daewoo DWA 151C User Manual
Danby DPAC10010 User Manual
Goodman Mfg Co LP Air Conditioner energy efficient air conditition User Manual
Goodman Mfg Co LP Air Conditioner Split System Air Conditioner User Manual
Haier Air Conditioner AC60FS1ERA User Manual