Residential & Light Commercial HVAC
Ultra Quiet Series
Electric Air Handler
11⁄
thru 5 Tons
2
208/230 Volt, 1-Phase, 60 Hz
The Fedders multi-position air handlers, when
matched with our air conditioners or heat pumps,
offer a complete line of quiet, efficient split
systems for today’s heating and cooling equipment.
Easy To Install And Service
Breaker accessible from front of unit when heater applied
Performance
External Access to heater circuit breakers pull /disconnects
Dual rated 208/230 volt operation
Provisions for field installed electrical connections from
either side of air handler cabinet
11⁄
to 5 tons
2
External sweat refrigerant connections
Built in filter rack
TXV – factory installed standard, which precisely controls
refrigerant distribution for improved comfort and cost savings
Pressure taps on suction and liquid line
Corrosion resistant condensate drain pan. Primary and
secondary drain
Standard Features
Multiposition installation, upflow or horizontal left standard,
horizontal right and downflow with minor modifications
Optional Features
Field installed heater packages from 5 kW – 20 kW
3-speed, permanently-lubricated PSC direct drive blower
motor is resilient mounted for ultra quiet, vibration-free
operation and flexible installation
Warranty
5-year limited parts warranty
Foil faced insulation reduces noise and bacterial growth and
features an easy to clean surface area
All indoor coils have copper tubing and aluminum fins
Time Delay relay comes standard and allows for retro-fit installations
3/4" primary and secondary drains on all models
Rated in Accordance with ARI Standard 210/240.
Certification Applies Only When Used with
Proper Components as Listed with ARI.
Additional rating information
AIR FLOW
RANGE
(CFM)
RECOMMENDED
FILTER SIZE
H x W x D (in)
SHIP/
OPERATIONS
WEIGHT (lbs)
DIMENSIONS
H x W x D (in)
MODEL
TONS
REFRIGERANT
AFPB24A1
AFPB24B1
AFPB36A1
AFPC48A1
AFPC48B1
AFPC60A1
AZFPC60B1
1.5 - 2
1.5 - 2
2.5 - 3
3.5 - 4
4
R-22
R-22
625 – 900
615 – 880
43 3/8 x 18 x 22
43 3/8 x 18 x 22
43 3/8 x 18 x 22
48 3/8 x 22 x 26
48 3/8 x 22 x 26
48 3/8 x 22 x 26
48 3/8 x 22 x 26
16 x 20 x 1
16 x 20 x 1
16 x 20 x 1
20 x 25 x 1
20 x 25 x 1
20 x 25 x 1
20 x 25 x 1
115 / 109
120 / 113
120 / 113
161 / 152
167 / 160
167 / 160
167 / 160
R-22
950 – 1,260
1,190 – 1,590
1,195 – 1,590
1,340 – 1,895
1,340 – 1,895
R-22
R-22
5
R-22
5
R-410A
Product Specifications
AIRFLOW PERFORMANCE
MEASURED STATIC PRESSURE INLET TO OUTLET
(INCHES WATER COLUMN)
MODEL
NUMBER
BLOWER
SPEED
0.20
925
0.30
900
0.40
850
0.50
795
0.60
690
HIGH
MEDIUM
800
760
745
670
N/A
AFPB24A1
AFPB24B1
AFPB36A1
LOW
HIGH
655
905
785
625
880
735
600
830
730
N/A
780
655
N/A
680
N/A
MEDIUM
LOW
HIGH
645
1440
1300
615
1350
1220
590
1260
1050
N/A
1180
940
N/A
1040
860
MEDIUM
LOW
HIGH
1160
1680
1440
1240
2230
1950
1360
1070
1640
1410
1220
2105
1930
1360
950
880
780
1590
1380
1190
1990
1840
1350
1520
1340
1150
1895
1770
1340
1430
1250
1100
1725
1590
1080
AFPC48A1
AFPC48B1
MEDIUM
LOW
HIGH
AFPC60A1
AZFPC60B1
MEDIUM
LOW
Specifications applicable to upflow and horizontal applications.
Air flow shown at the following conditions:
- No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits.
- 60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations.
- Dry coil airflow shown.
3
Specifications subject to change without notice.
Accessories
ELECTRIC HEATER KITS
DESCRIPTION
PART NUMBER
EEC05N1
EEC05B1
USE WITH MODEL SIZE
5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER
5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
7.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER
7.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
10 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER
10 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
15 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
20 KW, SINGLE PHASE, WITH CIRCUIT BREAKER
ALL
ALL
ALL
ALL
ALL
ALL
EEC07N1
EEC07B1
EEC10N1
EEC10B1
AFPB36A1, AFPC48A1, AFPC48B1,
AFPB60A1, AZFPB60B1
EEC15B1
AFPB36A1, AFPC48A1, AFPC48B1,
AFPB60A1, AZFPB60B1
EEC20B1
ELECTRIC HEAT - ELECTRICAL DATA
SINGLE CIRCUIT SUPPLY
DUAL CIRCUIT SUPPLY
kW
No. of
Heat
Load
Amps
Wire Size
Ground Size Min. Wire Ampacity Max. Fuse Size
Wire Size
Ground Size
Ckt 1 Ckt 2
MBTUH
208/240
Min.
Max.
240 Phase Supply
VAC
Wire Fuse
Ckt 1 Ckt 2
AWG / MM2 AWG / MM2 AWG / MM2 AWG / MM2
Circuits
AWG
MM2
AWG
MM2
Ckt 1
Ckt 2
Ckt 1
Ckt 2
Ampacity Size
0
1
1
1
1
1
1
1
1
1
1
-
-
5.0
30
15
30
14
10
8
2.1
5.3
14
10
10
10
8
2.1
5.3
5.3
5.3
8.4
13.3
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5*
14.8 / 17.1 20.9
22.1 / 25.6 31.3
29.5 / 34.1 41.7
7.5*
10*
15*
20*
43
50
8.4
-
-
-
-
57
60
6
13.3
21.2
33.6
-
-
-
-
1 or 2 44.3 / 51.2 62.5
1 or 2 59.0 / 68.2 83.4
83
90
4
57
57
26
53
60
60
30
60
6 / 13.3 10 / 5.3 10 / 5.3 10 / 5.3
6 / 13.3 10 / 13.3 10 / 5.3 10 / 5.3
109
110
2
6
NOTES:
*kW does not include motor watts.
Ampacities and over current protection based on largest air handler motor load. Refer to specific name plate for exact ampacity
and overcurrent protection size.
Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310,
for sizing conductors. NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated.
Maximum size fuse or HACR-type circuit breaker for field wiring protection.
Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit.
All wiring must conform to the National Electrical Code and all local codes.
4
Specifications subject to change without notice.
Product Specifications
5
Specifications subject to change without notice.
Electric Air Handler
Residential & Light Commercial Air Handler
Model Number Identification
R-22 Models
A F P B 24 A 1 * A
Product Type
A = Air Handler
Brand
Motor
P = PSC
Electrical Designation
1 = 208 / 230 Volts, 1 Phase, 60 Hz
2 = 220 Volts, 1 Phase, 50 Hz
3 = 208 / 230 Volts, 3 Phase, 60 Hz
4 = 460 Volts, 3 Phase, 60 Hz
5 = 230 Volts, 3 Phase, 50 Hz
6 = 380 Volts, 3 Phase, 50 Hz
Chassis Size
B = 43 3/8"H x 18"W x 22"D
C = 48 3/8"H x 22"W x 26"D
Nominal BTUH
24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW)
36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW)
42 = 42,000 BTU/H (12.31 kW)
Design Series
A = A Series
48 = 48,000 BTU/H (14.07 kW)
60 = 60,000 BTU/H (17.58 kW)
R-410A Models
A Z F P C 60 B 1 * A
Product Type
A = Air Handler
Electrical Designation
1 = 208 / 230 Volts, 1 Phase, 60 Hz
2 = 220 Volts, 1 Phase, 50 Hz
3 = 208 / 230 Volts, 3 Phase, 60 Hz
4 = 460 Volts, 3 Phase, 60 Hz
5 = 230 Volts, 3 Phase, 50 Hz
6 = 380 Volts, 3 Phase, 50 Hz
410A Refrigerant
Brand
Motor
P = PSC
Design Series
A = A Series
Nominal BTUH
Chassis Size
B = 43 3/8"H x 18"W x 22"D
C = 48 3/8"H x 22"W x 26"D
24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW)
36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW)
42 = 42,000 BTU/H (12.31 kW)
48 = 48,000 BTU/H (14.07 kW)
60 = 60,000 BTU/H (17.58 kW)
All product specifications reflect available information at the printing of this brochure.
Fedders Corporation
Fedders reserves the right to revise or modify products and/or specifications without notice.
Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.
505 Martinsville Rd.
Liberty Corner, NJ 07938 USA
(908) 604-8686
Form No. F-13AH
FD-015-0407-k
6
Specifications subject to change without notice.
|