Fedders AFPB24B1 User Manual

Residential & Light Commercial HVAC  
Ultra Quiet Series  
Electric Air Handler  
11⁄  
thru 5 Tons  
2
208/230 Volt, 1-Phase, 60 Hz  
The Fedders multi-position air handlers, when  
matched with our air conditioners or heat pumps,  
offer a complete line of quiet, efficient split  
systems for today’s heating and cooling equipment.  
Easy To Install And Service  
Breaker accessible from front of unit when heater applied  
Performance  
External Access to heater circuit breakers pull /disconnects  
Dual rated 208/230 volt operation  
Provisions for field installed electrical connections from  
either side of air handler cabinet  
11⁄  
to 5 tons  
2
External sweat refrigerant connections  
Built in filter rack  
TXV – factory installed standard, which precisely controls  
refrigerant distribution for improved comfort and cost savings  
Pressure taps on suction and liquid line  
Corrosion resistant condensate drain pan. Primary and  
secondary drain  
Standard Features  
Multiposition installation, upflow or horizontal left standard,  
horizontal right and downflow with minor modifications  
Optional Features  
Field installed heater packages from 5 kW – 20 kW  
3-speed, permanently-lubricated PSC direct drive blower  
motor is resilient mounted for ultra quiet, vibration-free  
operation and flexible installation  
Warranty  
5-year limited parts warranty  
Foil faced insulation reduces noise and bacterial growth and  
features an easy to clean surface area  
All indoor coils have copper tubing and aluminum fins  
Time Delay relay comes standard and allows for retro-fit installations  
3/4" primary and secondary drains on all models  
Rated in Accordance with ARI Standard 210/240.  
Certification Applies Only When Used with  
Proper Components as Listed with ARI.  
Additional rating information  
AIR FLOW  
RANGE  
(CFM)  
RECOMMENDED  
FILTER SIZE  
H x W x D (in)  
SHIP/  
OPERATIONS  
WEIGHT (lbs)  
DIMENSIONS  
H x W x D (in)  
MODEL  
TONS  
REFRIGERANT  
AFPB24A1  
AFPB24B1  
AFPB36A1  
AFPC48A1  
AFPC48B1  
AFPC60A1  
AZFPC60B1  
1.5 - 2  
1.5 - 2  
2.5 - 3  
3.5 - 4  
4
R-22  
R-22  
625 – 900  
615 – 880  
43 3/8 x 18 x 22  
43 3/8 x 18 x 22  
43 3/8 x 18 x 22  
48 3/8 x 22 x 26  
48 3/8 x 22 x 26  
48 3/8 x 22 x 26  
48 3/8 x 22 x 26  
16 x 20 x 1  
16 x 20 x 1  
16 x 20 x 1  
20 x 25 x 1  
20 x 25 x 1  
20 x 25 x 1  
20 x 25 x 1  
115 / 109  
120 / 113  
120 / 113  
161 / 152  
167 / 160  
167 / 160  
167 / 160  
R-22  
950 – 1,260  
1,190 – 1,590  
1,195 – 1,590  
1,340 – 1,895  
1,340 – 1,895  
R-22  
R-22  
5
R-22  
5
R-410A  
Product Specifications  
AIRFLOW PERFORMANCE  
MEASURED STATIC PRESSURE INLET TO OUTLET  
(INCHES WATER COLUMN)  
MODEL  
NUMBER  
BLOWER  
SPEED  
0.20  
925  
0.30  
900  
0.40  
850  
0.50  
795  
0.60  
690  
HIGH  
MEDIUM  
800  
760  
745  
670  
N/A  
AFPB24A1  
AFPB24B1  
AFPB36A1  
LOW  
HIGH  
655  
905  
785  
625  
880  
735  
600  
830  
730  
N/A  
780  
655  
N/A  
680  
N/A  
MEDIUM  
LOW  
HIGH  
645  
1440  
1300  
615  
1350  
1220  
590  
1260  
1050  
N/A  
1180  
940  
N/A  
1040  
860  
MEDIUM  
LOW  
HIGH  
1160  
1680  
1440  
1240  
2230  
1950  
1360  
1070  
1640  
1410  
1220  
2105  
1930  
1360  
950  
880  
780  
1590  
1380  
1190  
1990  
1840  
1350  
1520  
1340  
1150  
1895  
1770  
1340  
1430  
1250  
1100  
1725  
1590  
1080  
AFPC48A1  
AFPC48B1  
MEDIUM  
LOW  
HIGH  
AFPC60A1  
AZFPC60B1  
MEDIUM  
LOW  
Specifications applicable to upflow and horizontal applications.  
Air flow shown at the following conditions:  
- No heat elements in Air Handler. Decrease CFM 2% for 5 kW, 7.5 kW or 10 kW heat kits. Decrease CFM 1% for 15 kW or 20 kW heat kits.  
- 60 Hertz – 230 volts. Decrease CFM 6% for 208 volt operations.  
- Dry coil airflow shown.  
3
Specifications subject to change without notice.  
Accessories  
ELECTRIC HEATER KITS  
DESCRIPTION  
PART NUMBER  
EEC05N1  
EEC05B1  
USE WITH MODEL SIZE  
5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER  
5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER  
7.5 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER  
7.5 KW, SINGLE PHASE, WITH CIRCUIT BREAKER  
10 KW, SINGLE PHASE, WITHOUT CIRCUIT BREAKER  
10 KW, SINGLE PHASE, WITH CIRCUIT BREAKER  
15 KW, SINGLE PHASE, WITH CIRCUIT BREAKER  
20 KW, SINGLE PHASE, WITH CIRCUIT BREAKER  
ALL  
ALL  
ALL  
ALL  
ALL  
ALL  
EEC07N1  
EEC07B1  
EEC10N1  
EEC10B1  
AFPB36A1, AFPC48A1, AFPC48B1,  
AFPB60A1, AZFPB60B1  
EEC15B1  
AFPB36A1, AFPC48A1, AFPC48B1,  
AFPB60A1, AZFPB60B1  
EEC20B1  
ELECTRIC HEAT - ELECTRICAL DATA  
SINGLE CIRCUIT SUPPLY  
DUAL CIRCUIT SUPPLY  
kW  
No. of  
Heat  
Load  
Amps  
Wire Size Ž  
Ground Size  Min. Wire Ampacity Œ Max. Fuse Size   
Wire Size Ž  
Ground Size Ž  
Ckt 1 Ckt 2  
MBTUH  
208/240  
Min.  
Max.  
240 Phase Supply  
VAC  
Wire Œ Fuse   
Ckt 1 Ckt 2  
AWG / MM2 AWG / MM2 AWG / MM2 AWG / MM2  
Circuits  
AWG  
MM2  
AWG  
MM2  
Ckt 1  
Ckt 2  
Ckt 1  
Ckt 2  
Ampacity Size  
0
1
1
1
1
1
1
1
1
1
1
-
-
5.0  
30  
15  
30  
14  
10  
8
2.1  
5.3  
14  
10  
10  
10  
8
2.1  
5.3  
5.3  
5.3  
8.4  
13.3  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5*  
14.8 / 17.1 20.9  
22.1 / 25.6 31.3  
29.5 / 34.1 41.7  
7.5*  
10*  
15*  
20*  
43  
50  
8.4  
-
-
-
-
57  
60  
6
13.3  
21.2  
33.6  
-
-
-
-
1 or 2 44.3 / 51.2 62.5  
1 or 2 59.0 / 68.2 83.4  
83  
90  
4
57  
57  
26  
53  
60  
60  
30  
60  
6 / 13.3 10 / 5.3 10 / 5.3 10 / 5.3  
6 / 13.3 10 / 13.3 10 / 5.3 10 / 5.3  
109  
110  
2
6
NOTES:  
*kW does not include motor watts.  
Œ Ampacities and over current protection based on largest air handler motor load. Refer to specific name plate for exact ampacity  
and overcurrent protection size.  
Minimum wire ampacity values are used for sizing field power conductors. Refer to the National Electrical Code (latest version), Article 310,  
for sizing conductors. NOTE: when more than three current-carrying conductors are in the same conduit, the conductor's ampacity must be derated.  
 Maximum size fuse or HACR-type circuit breaker for field wiring protection.  
Ž Wire size based on 75°C copper wire with no more than three current-carrying conductors in the same conduit.  
All wiring must conform to the National Electrical Code and all local codes.  
4
Specifications subject to change without notice.  
Product Specifications  
5
Specifications subject to change without notice.  
Electric Air Handler  
Residential & Light Commercial Air Handler  
Model Number Identification  
R-22 Models  
A F P B 24 A 1 * A  
Product Type  
A = Air Handler  
Brand  
Motor  
P = PSC  
Electrical Designation  
1 = 208 / 230 Volts, 1 Phase, 60 Hz  
2 = 220 Volts, 1 Phase, 50 Hz  
3 = 208 / 230 Volts, 3 Phase, 60 Hz  
4 = 460 Volts, 3 Phase, 60 Hz  
5 = 230 Volts, 3 Phase, 50 Hz  
6 = 380 Volts, 3 Phase, 50 Hz  
Chassis Size  
B = 43 3/8"H x 18"W x 22"D  
C = 48 3/8"H x 22"W x 26"D  
Nominal BTUH  
24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW)  
36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW)  
42 = 42,000 BTU/H (12.31 kW)  
Design Series  
A = A Series  
48 = 48,000 BTU/H (14.07 kW)  
60 = 60,000 BTU/H (17.58 kW)  
R-410A Models  
A Z F P C 60 B 1 * A  
Product Type  
A = Air Handler  
Electrical Designation  
1 = 208 / 230 Volts, 1 Phase, 60 Hz  
2 = 220 Volts, 1 Phase, 50 Hz  
3 = 208 / 230 Volts, 3 Phase, 60 Hz  
4 = 460 Volts, 3 Phase, 60 Hz  
5 = 230 Volts, 3 Phase, 50 Hz  
6 = 380 Volts, 3 Phase, 50 Hz  
410A Refrigerant  
Brand  
Motor  
P = PSC  
Design Series  
A = A Series  
Nominal BTUH  
Chassis Size  
B = 43 3/8"H x 18"W x 22"D  
C = 48 3/8"H x 22"W x 26"D  
24 = 18,000/24,000 BTU/H (5.28 kW) / (7.03 kW)  
36 = 30,000/36,000 BTU/H (8.79 kW) / (10.55 kW)  
42 = 42,000 BTU/H (12.31 kW)  
48 = 48,000 BTU/H (14.07 kW)  
60 = 60,000 BTU/H (17.58 kW)  
All product specifications reflect available information at the printing of this brochure.  
Fedders Corporation  
Fedders reserves the right to revise or modify products and/or specifications without notice.  
Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc.  
505 Martinsville Rd.  
Liberty Corner, NJ 07938 USA  
(908) 604-8686  
Form No. F-13AH  
FD-015-0407-k  
6
Specifications subject to change without notice.  

Agilent Technologies 6843A User Manual
Briggs Stratton 44Q700 User Manual
Briggs Stratton 401400 User Manual
Brother MFC 7340 User Manual
Epson Stylus CX5400 User Manual
Friedrich 9 User Manual
Friedrich Air Conditioner Room Air Conditioner User Manual
Fusion EMPEROR L702B User Manual
Haier AU142AEAAA User Manual
Heat Controller Inc Air Conditioner RAD 283J User Manual