		 BARCODE IMAGER   
					Programming Manual   
					International Edition, Rev. C5   
				Revision History   
					Rev. No.   
					Released Date   
					Description   
					Rev.B Beta   
					Apr. 16, 2009   
					First Release   
					ꢀ Page 22   
					Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4”   
					and ISBT Concatenation On option code to “5”.   
					Rev.B   
					May 05, 2009   
					June 22, 2009   
					ꢀ Page 25   
					ꢀ Page 46   
					GS1 Databar Setting – All GS1 databar default values are changed to Enable.   
					Add “Symbology ID Table”.   
					ꢀ Page 34   
					ꢀ Page 37   
					Add “Presentation Scanning Mode”.   
					Add “Time Delay to Low Power Mode”.   
					Rev.B1   
					ꢀ Page 9, 11 Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code”.   
					ꢀ Page 26   
					Add “Composite Code Setting”, “PDF/Micro PDF417 Setting”,   
					“Codablock F Setting”, Korea Post Code Setting”.   
					Add “SmartStand Power Off Timeout”.   
					ꢀ Page 39   
					ꢀ Page 46   
					Rev.B2   
					Rev.B3   
					Aug. 21, 2009   
					Add “PDF417/Micro PDF417”, “Codablock F”, “Korea Post Code” into   
					Condensed DataWizard Table.   
					ꢀ Page 48   
					Add “PDF417/Micro PDF417”, “Codablock F”, “Composite Code”,   
					“Korea Post Code” IDs into Symbology ID Table.   
					ꢀ Page 8   
					Add “IBM PS/2, 25-30 series keyboard wedge interface”.   
					Oct. 16, 2009   
					ꢀ Page 39 Add “Presentation Scanning Auto-sense”.   
					ꢀ Page 48 Add “Code 128” ID into Symbology ID Table.   
					ꢀ Page 15 Modify UPC-E/EAN-8 expansion and UPC-A standardization   
					ꢀ Page 33 Rename “Time Out Control” to “Serial Response Time-out”.   
					ꢀ Page 35 Rename “Presentation Scanning Mode” to “Presentation Control”.   
					ꢀ Page 38 Rename “Auto Power Off Duration” to “Light Source On Time”.   
					Add “Extremely short” option to Good Read Duration.   
					Rev.B4   
					Rev. B5   
					Mar. 05, 2010   
					Apr.12, 2010   
					ꢀ Page 39 Rename “Presentation Scanning Auto-sense” to “Presentation Auto-sense”.   
					Add “Presentation Sensitivity”   
					ꢀ Page 54 System Commands – Add “Master Default” quick set command.   
					ꢀ Page 38 Hands Free Time-out – Add “Disable”.   
					ꢀ Page 39 Add “Trigger Control” (only available for FuzzyScan F460/F468).   
				Revision History   
					Rev. No.   
					Released Date   
					Description   
					Rev. B6   
					May 27, 2010 ꢀ Page 33   
					Baud Rate – Add 57.6K BPS and 115.2K BPS.   
					ꢀ Page 17   
					Add “UPC/EAN Security Level”.   
					Rev. B7   
					Rev. B8   
					Jun 25 , 2010 ꢀ Page 38   
					Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode"   
					and change the default value from 5 seconds to immediate.   
					ꢀ Page 15,16   
					ꢀ Page 17   
					Add “ Supplement Scan Voting”.   
					Add “EAN Supplement Control”.   
					ꢀ Page 28   
					Keyboard Layout – Add “Czech (QWERTY)”, remove “Universal”, and rename   
					Spain (QWERTY) to Spain (Spanish QWERTY), Latin America (QWERTY) to   
					Spain (Latin America, QWERTY).   
					Sep 29 , 2010   
					ꢀ Page 37   
					ꢀ Page 38   
					Add “Good Read Indicator”.   
					“Scan Rate Control”.   
					Rev. B9   
					Rev. C1   
					Nov 10 , 2010 ꢀ Page 34   
					Mar 04, 2011 ꢀ Page 34   
					Baud Rate – Cancel Baud Rate 300/600 BPS.   
					Baud Rate – Revise 57.6K BPS and 115.2K BPS option code from 6.7. to 8.9.   
					ꢀ Page 13   
					Add ”Code 39 Security Level”.   
					Add “NAK Retry Count”.   
					Rev. C2   
					Rev. C3   
					Mar 22, 2011 ꢀ Page 35   
					Add “ACK/NAK Transmission Indication”.   
					ꢀ Page 9, 19, 24, 51 UCC/EAN-128 was renamed GS1-128   
					ꢀ Page 35   
					ꢀ Page 36   
					ꢀ Page 44   
					Add new parameters to “ACK Indication”   
					Modify “Serial Response Time-out” parameters.   
					Add “Laser Aiming Control” function.   
					Jul 22, 2011   
					Rev. C4   
					Rev. C5   
					Nov 04, 2011 ꢀ Page 14   
					Add “Codabar Check Digit Settings”   
					ꢀ Page 38   
					Jan 02, 2012   
					Wand/Laser Emulation Control – Cancel “Output Polarity”, “Initial Signal   
					State”, “Margin Time”, “Module Time” ,and “Narrow/Wide Ratio”   
					ꢀ Page 38   
					Code 39/Code 128 Emulation – Change the default setting to option code 1.   
				© Copyright Cino Group   
					© Copyright PC Worth Int’l Co., Ltd   
					Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of   
					merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental   
					consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains   
					proprietary information that is protected by copyright. All rights are reserved. No part of this publication may be photocopied,   
					reproduced or translated into any language, in any forms, in an electronic retrieval system or otherwise, without prior written   
					permission of Cino. All product information and specifications shown in this document may be changed without prior notice.   
					Warranty   
					Cino warrants its products against defects in workmanship and materials from the date of shipment, provided that the   
					product is operated under normal and proper conditions. The warranty provisions and durations are furnished by different   
					warranty programs. The above warranty does not apply to any product which has been (i) misused; (ii) damaged by accident   
					or negligence; (iii) modified or altered by the purchaser or other party; (iv) repaired or tampered by unauthorized   
					representatives; (v) operated or stored beyond the specified operational and environmental parameters; (vi) applied   
					software, accessories or parts are not supplied by Cino; (vii) damaged by circumstances out of Cino’s control, such as, but   
					not limited to, lightning or fluctuation in electrical power. Any defective product must follow the warranty program and RMA   
					procedures to return Cino for inspection.   
					Regulatory   
					FCC part 15B   
					EN55022, EN55024, EN61000-3-2, EN61000-3-3, EN60950-1, EN61000-6-3, EN61000-6-2   
					CNS13438   
					AS/NZS CISPR 22:2009 Class B   
					KN22, KN24 (KN61000-2,-3,-4,-5,-6,-8,-11)   
				LED Eye Safety   
					Laser Eye Safety   
					IEC62471 Exempt group   
					IEC60825-1 Class 1   
				Table of Contents   
					Getting Started   
					Getting Familiar with Your FuzzyScan   
					Connecting to Your Host   
					Using Accessories   
					1 
					1 
					2 
					Configure Your FuzzyScan   
					Bar Code Programming Manual   
					Programming Procedures   
					Host Interface Selection   
					Symbology Reading Control   
					Keyboard Interface Control   
					Serial Interface Control   
					3 
					4 
					8 
					9 
					23   
					32   
					35   
					36   
					41   
					Wand/Laser Emulation Control   
					Operation Control   
					Condensed DataWizard   
					Appendix   
					Symbology ID Table   
					48   
					49   
					50   
					51   
					52   
					53   
					54   
					Keyboard Function Code Table   
					ASCII Input Shortcut   
					Host Interface Quick Set   
					Operation Mode Quick Set   
					Option Codes   
					System Commands   
				Getting Started   
					Getting Familiar with Your FuzzyScan   
					Connecting to Your Host   
					Thank you for choosing Cino FuzzyScan Imager. All   
					FuzzyScan imagers deliver world-class performance for a   
					broad range of applications to unleash your productivity. This   
					document provides an easy reference for installation and   
					operation purposes. A complete documentation is provided   
					by the FuzzyScan Programming Manual available at   
					
					FuzzyScan imagers support PS/2(DOS/V) Keyboard   
					Wedge, RS-232 Serial, and USB interfaces. Please   
					choose your desired interface cable, then plug it into the   
					cable interface port of the imager and connect it to the   
					host. If you would like to remove the cable, please   
					straighten one end of a paper clip, then insert it into the   
					cable release hole to pull out the cable.   
					F700 & L700 Series   
					USB   
					F600 & L600 Series   
					Power Indicator   
					Status Indicator   
					Trigger   
					RS232 Serial   
					Scan Window   
					Beeper   
					Cable Release Hole   
					F400 Series   
					PS/2(DOS/V) Keyboard Wedge   
					1 
				Getting Started   
					Using Accessories   
					You can enhance productivity of your workforce by using   
					various accessories to fulfill a wide variety of application   
					demand.   
					Universal Holder   
					A stylish Universal Holder is designed for   
					storing your imager when not in use. It   
					serves to protect the imager from   
					lens-scratched or falling. Moreover, its   
					artistic-design enhances the entire value   
					of the imager.   
					Hand-free SmartStand   
					A SmartStand is specifically designed   
					for hand-free applications to maximize   
					user’s comfort and productivity. You   
					can adjust the scanner holder to   
					desired   
					position   
					for   
					optimized   
					scanning.   
					Thanks to the auto-sense design, the   
					imager is capable of switching   
					between presentation scanning and   
					hand-held scanning automatically   
					while working with SmartStand.   
					Please note that the SmartStand is   
					not applicable for F400 Series imager.   
					2 
				Configure Your FuzzyScan   
					Bar Code Programming Menu   
					The FuzzyScan bar code commands are specially designed   
					Proprietary bar code labels which allow you to set the   
					FuzzyScan internal programming parameters. There are   
					System Command, Family Code and Option Code for   
					programming purpose.   
					System Command   
					The System Command is the highest level bar code   
					command which directs FuzzyScan to perform immediate   
					operations, such as entering programming mode   
					(PROGRAM), exiting programming mode (EXIT), listing   
					system information (SYSLIST), recovering to factory   
					preset configurations (M_DEFAULT) and so on. Please   
					note that all system commands will take a few seconds to   
					complete the operations. User must wait for the   
					completion beeps before scanning another bar code.   
					Each programmable family and bar code command label is   
					listed on the same page with major system commands. The   
					detailed explanations and special programming flowchart are   
					printed on facing or following pages. You can read the   
					explanation and set the FuzzyScan concurrently.   
					A supplemental bar code command menu incorporates the   
					bar code command labels of System Command and Option   
					Code. As you set the FuzzyScan, open the bar code   
					command menu to find the option code page. You may scan   
					the desired family code and option code to set FuzzyScan. If   
					you want to change the programming family for multiple   
					settings, you need only turn over the programming page to   
					find next desired programming family.   
					Family Code   
					The Family Code is scanned to select the user desired   
					programming family. FuzzyScan has already provided   
					more than one hundred programming families to meet any   
					specific requirements.   
					Option Code   
					The Option Codes is a set of bar code commands   
					represented by “0–9”, “A–F” and finishing selection (FIN).   
					For most setting, you must select at least one option code   
					following the family code selection to set the desired   
					parameter for the selected programming family.   
					3 
				Configure Your FuzzyScan   
					Programming Procedures   
					As you scan the bar code command to select the desired   
					parameters, information about the final selected parameters   
					represented by the bar code commands are stored in the   
					FuzzyScan’s internal Flash Memory ASIC or non-volatile   
					memory. If you turn off the unit, the Flash Memory ASIC or   
					non-volatile memory retains all programming options. You   
					need not re-program the FuzzyScan if you want to keep the   
					existing configurations in the next power on.   
					If the programming family must take multiple scans   
					selection, cycling scan selection, or dual level selection   
					procedures, the family of the programming menu will be   
					marked with the matched representing symbol of   
					Programming Category (P.C.) in bold font listed in the   
					following table. You can easily find the bold mark in the   
					programming menu, and refer to their flowcharts for details.   
					Before setting the FuzzyScan, please also refer to the   
					“Beeping Indications” listed in Appendix to understand the   
					details of programming beeping indications. It will be very   
					helpful for you to know the existing status while you are   
					programming the FuzzyScan.   
					The programming procedures of FuzzyScan are designed   
					as simple as possible for ease of setting. Most   
					programming families take the Single Scan Selection   
					programming procedure. But several programming families   
					have more complex and flexible programmable options,   
					and you must take Multiple Scans Selection, Cycling   
					Scan Selection or Dual Level Selection to complete their   
					programming procedures. Each kind of programming   
					procedure is listed in the following pages for your reference.   
					Please give careful attention to become familiar with each   
					programming procedure.   
					Conventions of Programming Menu   
					Conventions   
					Descriptions   
					Factory Default Value   
					Programming Category   
					ꢁ 
					P.C.   
					SS : Single scan selection   
					MS : Multiple scans selection   
					CS : Cycling scan selection   
					DS : Dual level scan selection   
					( 
					[ 
					) 
					] 
					Necessary Option Code   
					Selectable Option Code   
					4 
				Configure Your FuzzyScan   
					Program & End   
					System List, Group & Master Default   
					Scan   
					Scan   
					“ 
					” 
					“PROGRAM”   
					SYSLIST   
					FuzzyScan will list the product information and   
					revision number to host via selected host interface,   
					then issue the completion beeping.   
					FuzzyScan will enter programming mode,   
					and inhibit all non-programming functions.   
					Scan   
					Scan   
					“M_DEFAULT”   
					“END”   
					FuzzyScan will exit programming mode, and store all   
					parameters in Flash Memory ASIC or non-volatile memory,   
					then issue the completion beeping.   
					FuzzyScan will recover all programmable   
					parameters into factory preset configurations,   
					then issue the completion beeping.   
					Please note that the FuzzyScan will take 3-4 seconds to   
					store parameters in internal Flash Memory ASIC or   
					non-volatile memory after you scan the “END”. Please   
					don’t turn off the power before the completion beeping. It   
					may destroy all configured parameters.   
					5 
				Configure Your FuzzyScan   
					Single scan selection   
					Multiple scans selection   
					Scan   
					Scan   
					Enter programming mode.   
					“PROGRAM”   
					Enter programming mode.   
					“ 
					” 
					PROGRAM   
					Select one of desired   
					programming families.   
					Select one of desired   
					programming families.   
					Scan   
					Scan   
					One of Family Codes   
					One of   
					Codes   
					Family   
					1. Select one or several   
					option codes to select   
					desired parameters.   
					Select one option code of   
					desired parameter.   
					Scan One or   
					Scan   
					Several   
					Codes   
					Option   
					One of Option Codes   
					2. If it’s necessary, scan   
					“FIN” to terminate   
					Yes   
					Want to select another   
					programming family?   
					option code selection.   
					Yes   
					Repeat   
					Repeat   
					Selection   
					Selection   
					Want to select another   
					programming family?   
					No   
					No   
					Scan   
					Scan   
					Exit programming mode.   
					Exit programming mode.   
					“END”   
					“ 
					” 
					END   
					6 
				Configure Your FuzzyScan   
					Cycling scan selection   
					Dual level selection   
					Scan   
					Scan   
					Enter programming mode.   
					“PROGRAM”   
					Enter programming mode.   
					“PROGRAM”   
					Select one of desired   
					programming families.   
					Select one of desired   
					programming families.   
					Scan   
					Scan   
					One of Family Codes   
					One of Family Codes   
					Cycling select one or   
					several option codes of   
					desired parameters as   
					“Single” or “Multiple”   
					scans selection.   
					Select several option codes   
					of desired parameters.   
					(1st) Scan   
					Scan   
					Several Option Codes   
					One of Option Codes   
					1. Select one or several   
					option codes of desired   
					parameters.   
					(2nd) Scan One or   
					Scan “FIN”   
					Several   
					Codes   
					Option   
					2. If it’s necessary, scan   
					“FIN” to terminate   
					Finish cycling selection.   
					(If necessary)   
					option code selection.   
					Yes   
					Yes   
					Repeat   
					Repeat   
					Selection   
					Selection   
					Want to select another   
					programming family?   
					Want to select another   
					programming family?   
					No   
					No   
					Scan   
					Scan   
					Exit programming mode.   
					Exit programming mode.   
					“ 
					” 
					END   
					“ 
					” 
					END   
					7 
				Configure Your FuzzyScan   
					Host Interface Selection   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Host Interface Selection   
					P.C   
					Parameter Selection   
					Option Code   
					MS   
					MS   
					MS   
					MS   
					MS   
					MS   
					MS   
					MS   
					MS   
					MS   
					IBM PS/2, 25-30 series keyboard wedge interface   
					Standard/TTL RS-232 peer-to-peer serial   
					Wand emulation   
					02   
					06   
					08   
					09   
					10   
					13   
					14   
					17   
					18   
					19   
					USB Com Port Emulation   
					PS/2 (DOS/V) direct link (keyboard replacement)   
					PS/2 (DOS/V) keyboard wedge turbo mode   
					PS/2 (DOS/V) keyboard wedge standard mode   
					Laser emulation   
					ꢁ 
					USB HID standard mode   
					USB HID turbo mode   
					8 
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ User Defined Symbol ID ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Symbol ID : 1 character   
					P.C   
					Parameter Selection   
					Option Code   
					2nd Option Code   
					DS   
					Code 128 (default=B)   
					GS1-128 (default=C)   
					UPC-A (default=A)   
					EAN-13 (default=F)   
					Codabar/NW-7 (default=D)   
					Code 39/Code 32 (default=G)   
					Code 93 (default=H)   
					Standard/Industrial 2 of 5 (default=I)   
					Interleaved 2 of 5 (default=J)   
					Matrix 2 of 5 (default=K)   
					China Postal Code (default=L)   
					German Postal Code (default=M)   
					IATA (default=O)   
					00   
					01   
					02   
					03   
					04   
					05   
					06   
					07   
					08   
					09   
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					26   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					(1 character)   
					Code 11 (default=P)   
					MSI/Plessey (default=R)   
					UK/Plessey (default=S)   
					Telepen (default=T)   
					GS1 DataBar (default=X)   
					UPC-E (default=E)   
					EAN-8 (default=N)   
					Trioptic Code 39 (Default=W)   
					UCC Coupon Extended Code (Default=Z)   
					PDF417/Micro PDF417 (default=V)   
					Codablock F (default=Y)   
					Korea Post Code (default =a)   
					9 
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Symbology ID Transmission ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Symbology ID Transmission   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable symbology ID transmission   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					Enable prefix CINO symbology ID transmission   
					Enable suffix CINO symbology ID transmission   
					Enable both prefix and suffix CINO symbology ID transmission   
					Enable prefix AIM symbology ID transmission   
					Enable suffix AIM symbology ID transmission   
					Enable both prefix and suffix AIM symbology ID transmission   
					10   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Readable Bar Code Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Readable Symbology Setting   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					CS   
					Auto   
					00   
					01   
					02   
					03   
					04   
					05   
					06   
					07   
					47   
					08   
					38   
					48   
					58   
					68   
					09   
					10   
					11   
					12   
					13   
					14   
					15   
					17   
					18   
					21   
					Code 128 *   
					UPC-A *   
					UPC-E *   
					EAN-13 *   
					EAN-8 *   
					Codabar/NW-7 *   
					Code 39 *   
					Trioptic Code 39   
					Standard/Industrial 2 of 5   
					Matrix 2 of 5   
					Interleaved 2 of 5 *   
					China Postal Code   
					German Postal Code   
					Code 93 *   
					Code 11   
					MSI/Plessey   
					UK/Plessey   
					Telepen   
					GS1 DataBar (RSS-14) *   
					IATA   
					PDF417/Micro PDF417   
					Codablock F   
					Korea Post Code   
					Remember to scan “FIN” to terminate   
					this selection. But if you select the   
					“ Auto ”, FuzzyScan will terminate this   
					selection automatically.   
					ꢂ 
					If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error. Furthermore, to add   
					the “Symbology ID” into the transmitted data is also helpful to identify the specific symbology.   
					ꢂ 
					ꢂ 
					Above symbologies marketed with * are enable as default. When you select “Auto”, the imager only read those symbologies marked with *.   
					When you set the minimum and maximum length of each symbology, please note the data length of scanned bar code doesn’t include star/stop characters.   
					11   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Code 39/Code 32 Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Code 39 Family Setting   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Code 39   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					E 
					ꢁ 
					Enable Code 39   
					Select Standard Code 39 as primary format   
					ꢁ 
					Select Full ASCII Code 39 as primary format   
					Select Code 32 (PARAF, Italian Pharmaceutical) as primary format   
					ꢁ 
					Disable start/stop symbol transmission   
					Enable start/stop symbol transmission   
					ꢁ 
					Disable Code 32 leading A transmission   
					Enable Code 32 leading A transmission   
					Disable MOD 43 check digit verification   
					Enable MOD 43 check digit verification   
					ꢁ 
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					Disable Code 39 buffering   
					Enable Code 39 buffering   
					ꢁ 
					SS   
					SS   
					Disable Trioptic Code 39   
					Enable Trioptic Code 39   
					0 
					1 
					Trioptic Code 39 Setting   
					Code 39 Min. Length   
					Code 39 Max. Length   
					ꢁ 
					SS   
					MS   
					Default (01)   
					FIN   
					(2 digits)   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢂ 
					Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.   
					12   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Code 39 Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Code 39 Security Level   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					Level 0   
					Level 1   
					Level 2   
					Level 3   
					0 
					1 
					2 
					3 
					ꢁ 
					ꢂ 
					Code 39 Security Level   
					The scanner offers four levels of decode security for Code39 bar codes:   
					Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.   
					Level 1: If you are experiencing misread of poorly-printed or out-of-spec. bar codes in level 2, please select level 1.   
					Level 2: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” Code39 bar codes.   
					Level 3: If you failed to read poorly-printed or out-of-spec. bar codes in level 2, please select level 3. This is the most aggressive setting and may increase the misread.   
					13   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Codabar/NW-7 Setting ♦   
					PROGRAM   
					Family Code Selection   
					Codabar Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Codabar   
					Enable Codabar   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					E 
					ꢁ 
					ꢁ 
					Select Codabar standard format   
					Select Codabar ABC format   
					Select Codabar CLSI format   
					Select Codabar CX format   
					ꢁ 
					Disable start/stop symbol transmission   
					Enable ABCD/ABCD start/stop symbol transmission   
					Enable abcd/abcd start/stop symbol transmission   
					Enable ABCD/TN*E start/stop symbol transmission   
					Enable abcd/tn*e start/stop symbol transmission   
					ꢁ 
					Disable check digit verification   
					Enable check digit verification   
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Modulus 16   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					Codabar Check Digit Settings   
					Modulus 10/weight 3   
					Modulus 11   
					Modulus 10/weight 2   
					7 check DR   
					Weight Modulus 11   
					Runes (Modulus 10/weight 2)   
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					Codabar Min. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					14   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Codabar/NW-7 Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Codabar Max. Length   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					15   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ UPC-A & UPC-E Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					UPC Family Setting   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable UPC-A   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					E 
					F 
					ꢁ 
					ꢁ 
					Enable UPC-A   
					Disable UPC-E   
					Enable UPC-E   
					Disable UPC-E expansion   
					Enable UPC-E expansion   
					ꢁ 
					ꢁ 
					ꢁ 
					Disable UPC standardization   
					Enable UPC standardization   
					Disable UPC numeric system   
					Enable UPC numeric system   
					Disable UPC-A check digit transmission   
					Enable UPC-A check digit transmission   
					Disable UPC-E check digit transmission   
					Enable UPC-E check digit transmission   
					ꢁ 
					ꢁ 
					ꢁ 
					Disable UPC “leading 1” portion   
					Enable UPC “leading 1” portion   
					ꢂ 
					When enable UPC-E expansion, the UPC-E decoded data will be converted to UPC-A format and affected by related setting, such as UPC standardization, UPC numeric   
					system, UPC-A check digit transmission.   
					ꢂ 
					ꢂ 
					ꢂ 
					UPC-E & EAN-8 Expansion   
					UPC-A Standardization   
					UPC Lead 1 Numeric System   
					: Expand the 8-digit UPC-E and 8-digit ENA-8 to 12-digit UPC-A and 13-digit EAN-13.   
					: Expand the 12-digit UPC-A to 13-digit EAN-13 with 1 zero insertion.   
					: Enable to read UPC leading with the 1 numeric system, you must enable this option.   
					WPC Selection   
					(UPC/EAN/CAN)   
					Disable   
					Check Digit   
					Disable   
					Numeric System   
					With 2-digit   
					Addendum   
					With 5-digit   
					Addendum   
					Enable   
					Standardization   
					Enable   
					Expansion   
					Basic Length   
					UPC-A   
					UPC-E   
					EAN-13   
					EAN-8   
					12   
					8 
					13   
					8 
					- 1   
					- 1   
					- 1   
					- 1   
					- 1   
					- 1   
					NC   
					NC   
					+ 2   
					+ 2   
					+ 2   
					+ 2   
					+ 5   
					+ 5   
					+ 5   
					+ 5   
					+ 1   
					+ 1   
					NC   
					NC   
					0 
					+ 4   
					0 
					+ 5   
					16   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ UPC-A & UPC-E Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					UPC Supplement Setting   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Select UPC without supplement digits   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					Select UPC with only 2 supplement digits   
					Select UPC with only 5 supplement digits   
					Select UPC with 2/5 supplement digits   
					ꢁ 
					Disable force supplement digits output   
					Enable force supplement digits output   
					ꢁ 
					UPC Family Addenda Separator Off   
					UPC Family Addenda Separator On   
					SS   
					SS   
					Level 0   
					Level 1   
					Level 2   
					0 
					1 
					UPC/EAN Security Level   
					Supplement Scan Voting   
					ꢁ 
					SS   
					2 
					Only available for UPC-A & EAN-13   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					Level 1   
					Level 2   
					Level 3   
					Level 4   
					Level 5   
					Level 6   
					Level 7   
					Level 8   
					Level 9   
					Level 10   
					Level 11   
					Level 12   
					Level 13   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					ꢁ 
					ꢂ 
					UPC/EAN Security Level   
					The scanner offers three levels of decode security for UPC/EAN bar codes:   
					Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this   
					security level may significantly impair the decoding ability of the scanner.   
					Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.   
					Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may   
					increase the misread.   
					ꢂ 
					The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding   
					a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5   
					supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,   
					low contrast or damage barcode labels.   
					17   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ EAN Setting, EAN Supplement Setting ♦   
					PROGRAM   
					Family Code Selection   
					EAN Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable EAN-13   
					Enable EAN-13   
					Disable EAN-8   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					ꢁ 
					ꢁ 
					Enable EAN-8   
					ꢁ 
					Disable EAN-8 expansion   
					Enable EAN-8 expansion   
					Disable EAN-13 check digit transmission   
					Enable EAN-13 check digit transmission   
					Disable EAN-8 check digit transmission   
					ꢁ 
					ꢁ 
					Enable EAN-8 check digit transmission   
					ꢁ 
					Disable ISBN/ISSN Conversion reading check   
					Enable ISBN/ISSN Conversion reading check   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Select EAN without supplement digits   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					EAN Supplement Setting   
					Select EAN with only 2 supplement digits   
					Select EAN with only 5 supplement digits   
					Select EAN with 2/5 supplement digits   
					ꢁ 
					Disable force supplement digits output   
					Enable force supplement digits output   
					ꢁ 
					EAN Addenda Separator Off   
					EAN Addenda Separator On   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					Level 1   
					Level 2   
					Level 3   
					Level 4   
					Level 5   
					Level 6   
					Level 7   
					Level 8   
					Level 9   
					Level 10   
					Level 11   
					Level 12   
					Level 13   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					Supplement Scan Voting   
					ꢁ 
					ꢂ 
					The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding   
					a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5   
					supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3. When you select higher level, it may impact the reading speed on poorly-printed,   
					low contrast or damage barcode labels.   
					18   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ EAN Security Level Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					UPC/EAN Security Level   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					Level 0   
					Level 1   
					Level 2   
					0 
					1 
					ꢁ 
					SS   
					2 
					Only available for UPC-A & EAN-13   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable all specific prefix supplement digital output   
					Enable all specific prefix supplement digital output   
					Enable 491 Supplement Digit Output   
					Enable 978/979 Supplement Digit Output   
					Enable 977 Supplement Digit Output   
					Enable 378/379 Supplement Digit Output   
					Enable 414/419 Supplement Digit Output   
					Enable 434/439 Supplement Digit Output   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					EAN Supplement Control   
					ꢂ 
					UPC/EAN Security Level   
					The scanner offers three levels of decode security for UPC/EAN bar codes:   
					Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this   
					security level may significantly impair the decoding ability of the scanner.   
					Level 1: This is the default setting which allows the scanner to operate fastest, while providing sufficient security in decoding “in-spec” UPC/EAN bar codes.   
					Level 2: If you are experiencing misread of poorly-printed, soiled or damage bar codes in level 1, please select level 2. This is the most aggressive setting and may   
					increase the misread.   
					ꢂ 
					EAN Supplement Control   
					If you select EAN with only 2, or 5 or 2/5 supplement digits and enable 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5 or 2/5 supplement   
					digits bar codes starting with 491 prefix. The EAN without supplement digit will not be transmitted.   
					If you select EAN with only 2, or 5 or 2/5 supplement digits and enable the other except 491 prefix supplement digit output, the scanner will transmit EAN with 2, or 5, or 2/5   
					supplement digits bar codes starting with specific prefix. The EAN without supplement digit will be transmitted.   
					19   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ UCC Coupon Extended Code Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					UCC Coupon Extended Code   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					Disable UCC Coupon Extended Code   
					Enable UCC Coupon Extended Code   
					0 
					1 
					ꢂ 
					UCC Coupon Extended Code   
					When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128   
					Coupon Codes. UPC-A, EAN-13 and EAN-128 must be enabled to scan all types of Coupon Codes.   
					20   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ IATA & Interleaved 2 of 5 Setting ♦   
					PROGRAM   
					Family Code Selection   
					IATA Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable IATA   
					Enable IATA   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					ꢁ 
					Select 15-digit fixed length IATA checking   
					Select variable length IATA   
					ꢁ 
					Disable check digit verification   
					Enable check digit automatic verification   
					Enable S/N checking digit verification only   
					Enable CPN checking digit verification only   
					Enable CPN, Airline and S/N check digit verification   
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					Disable start/stop symbol transmission   
					Enable start/stop symbol transmission   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Interleaved 2 of 5   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					Interleaved 2 of 5 Setting   
					ꢁ 
					Enable Interleaved 2 of 5   
					Select Interleaved 2 of 5 as primary format   
					Select German Postal Code as primary format   
					ꢁ 
					ꢁ 
					No check character   
					Validate USS check digit   
					Validate OPCC check digit   
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					21   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Code 25 Family Setting ♦   
					PROGRAM   
					Family Code Selection   
					Code 25 Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Standard/Industrial 2 of 5   
					Enable Standard/Industrial 2 of 5   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					ꢁ 
					Disable Matrix 2 of 5   
					Enable Matrix 2 of 5   
					ꢁ 
					Disable China Postal Code   
					Enable China Postal Code   
					ꢁ 
					Disable check digit verification   
					Enable check digit verification   
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					Code 25 Family Min. Length   
					Code 25 Family Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢂ 
					For Code25 setting, we recommend you to select only one type of Code 25 or set the maximum/minimum bar code length. To decode all types of Code 25 or to variable   
					length of Code 25 will increase the possibility of reading error.   
					22   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Code 11 & Code 93 Setting ♦   
					PROGRAM   
					Family Code Selection   
					Code 11 Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Code 11   
					Enable Code 11   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					ꢁ 
					Disable check digit verification   
					Select 1-check digit verification   
					Select 2-check digit verification   
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					Code 11 Min. Length   
					Code 11 Max. Length   
					Code 93 Setting   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					SS   
					SS   
					SS   
					SS   
					Disable Code 93   
					Enable Code 93   
					Disable check digit transmission   
					Enable check digit transmission   
					0 
					1 
					2 
					3 
					ꢁ 
					ꢁ 
					ꢁ 
					SS   
					MS   
					Default (01)   
					FIN   
					(2 digits)   
					Code 93 Min. Length   
					Code 93 Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					23   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ MSI/Plessey Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					MSI/Plessey Setting   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable MSI/Plessy   
					Enable MSI/Plessy   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					ꢁ 
					Select MOD 10 check digit   
					Select MOD 10-10 check digit   
					Select MOD 11-10 check digit   
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					MSI/Plessey Min. Length   
					MSI/Plessey Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					24   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Code 128 & UCC/EAN 128 Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Code 128/EAN-128 Setting   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Code 128 and GS1-128   
					0 
					1 
					2 
					3 
					4 
					5 
					ꢁ 
					Enable Code 128 and GS1-128   
					ꢁ 
					Disable function code conversion   
					Enable function code conversion   
					ꢁ 
					ISBT Concatenation Off   
					ISBT Concatenation On   
					ꢁ 
					SS   
					MS   
					Default (01)   
					FIN   
					(2 digits)   
					Code 128/EAN-128 Min. Length   
					Code 128/EAN-128 Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					25   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ UK/Plessey Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					UK/Plessey Setting   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable UK/Plessey   
					Enable UK/Plessey   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					ꢁ 
					Select UK/Plessey Standard Format   
					Select UK/Plessey CLSI Format   
					ꢁ 
					Disable Convert X to A-F   
					Enable Convert X to A-F   
					ꢁ 
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					UK/Plessey Min. Length   
					UK/Plessey Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					26   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Telepen Setting ♦   
					PROGRAM   
					Family Code Selection   
					Telepen Setting   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable Telepen   
					Enable Telepen   
					0 
					1 
					2 
					3 
					4 
					5 
					ꢁ 
					Select Telepen Numeric mode   
					Select Telepen Full ASCII mode   
					Disable check digit transmission   
					Enable check digit transmission   
					ꢁ 
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					Telepen Min. Length   
					Telepen Max. Length   
					01-Maximum   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (98)   
					98-Minimum   
					FIN   
					(2 digits)   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					27   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ GS1 DataBar Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					GS1 DataBar Setting   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable GS1 DataBar (RSS-14)   
					0 
					1 
					2 
					3 
					4 
					5 
					ꢁ 
					Enable GS1 DataBar (RSS-14)   
					Disable GS1 DataBar Limited   
					ꢁ 
					Enable GS1 DataBar Limited   
					Disable GS1 DataBar Expanded   
					Enable GS1 DataBar Expanded   
					ꢁ 
					ꢁ 
					SS   
					MS   
					Default (04)   
					FIN   
					(2 digits)   
					GS1 DataBar Min. Length   
					GS1 DataBar Max. Length   
					01-Maximum   
					Only available for Expanded GS1 Databar.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					Default (74)   
					74-Minimum   
					FIN   
					(2 digits)   
					Only available for Expanded GS1 Databar.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					28   
				Configure Your FuzzyScan   
					Symbology Reading Control   
					♦ Linear-stacked & Korea Post Code Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Composite Codes Setting   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					Disable composite codes   
					Enable composite codes   
					0 
					1 
					2 
					3 
					ꢁ 
					UPC Composite Mode: UPC never linked   
					UPC Composite Mode: UPC always linked   
					SS   
					SS   
					SS   
					SS   
					Disable PDF417   
					Enable PDF417   
					Disable MicroPDF417   
					Enable MicroPDF417   
					0 
					1 
					2 
					3 
					PDF417/Micro PDF417 Setting   
					Codablock F Setting   
					ꢁ 
					ꢁ 
					ꢁ 
					SS   
					SS   
					Disable   
					Enable   
					0 
					1 
					ꢁ 
					SS   
					SS   
					Disable   
					Enable   
					0 
					1 
					Korea Post Code Setting   
					Length fixed in 6 characters.   
					ꢂ 
					Composite Codes Setting   
					If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted regardless of whether a MicroPDF417 symbol is detected.   
					If UPC Composite Mode: UPC always linked is selected, UPC barcodes are only transmitted when the MicroPDF417 is detected.   
					29   
				Configure Your FuzzyScan   
					Keyboard Interface Control   
					♦ Keyboard Layout (Language) Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Keyboard Layout   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					USA (QWERTY)   
					00   
					01   
					02   
					03   
					04   
					05   
					06   
					07   
					08   
					09   
					10   
					11   
					12   
					13   
					14   
					15   
					16   
					17   
					France (AZERTY)   
					Germany (QWERTZ)   
					United Kingdom - UK (QWERTY)   
					Canadian French (QWERTY)   
					Spain (Spanish, QWERTY)   
					Sweden/Finland (QWERTY)   
					Portugal (QWERTY)   
					Norway (QWERTY)   
					Spain (Latin America, QWERTY)   
					Italy (QWERTY)   
					Netherlands (QWERTY)   
					Denmark (QWERTY)   
					Belgium (AZERTY)   
					Switzerland-Germany (QWERTY)   
					Iceland (QWERTY)   
					Japan (DOS/V)   
					Czech (QWERTY)   
					ꢂ 
					ꢂ 
					ꢂ 
					Please refer to the ASCII/HEX Table listed in the Appendix to determine HEX codes for characters, symbols, and functions to be used as preamble or postamble.   
					To set preamble or postamble as function key output, you must enable the “Function Key Emulation” feature as listed in page 3-25 first.   
					Keyboard Interface Message String :   
					Preamble   
					Data Length   
					2-3 digits   
					Prefix Symbol ID   
					1 or 2 characters   
					Scanned Data   
					Suffix Symbol ID   
					1 or 2 characters   
					Postamble   
					Record Suffix   
					1 character   
					1-15 characters   
					Variable length   
					1-15 characters   
					30   
				Configure Your FuzzyScan   
					Keyboard Interface Control   
					♦ Record Suffix, Preamble, Postamble & Caps Lock ♦   
					PROGRAM   
					Family Code Selection   
					Record Suffix   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					RETURN   
					TAB   
					0 
					1 
					2 
					3 
					4 
					ꢁ 
					SPACE   
					ENTER (Numeric Key Pad)   
					User defined character (1 character)   
					5, (00-7F)   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					Preamble   
					Postamble   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢁ 
					SS   
					SS   
					SS   
					“Caps Lock Off” State   
					“Caps Lock On” State   
					0 
					1 
					2 
					Caps Lock Control   
					Caps Lock Release Control   
					Auto Detect (PC/AT, PS/2, Keyboard Replacement and DOS/V Machines only)   
					ꢁ 
					SS   
					SS   
					“Caps Lock On, Caps Off”   
					“Caps Lock On, Shift Off”   
					0 
					1 
					ꢂ 
					ꢂ 
					The function of “Caps Lock Control” and “Key Pad Emulation” are only available for IBM PC/AT, PS/VP, PS/2 series personal computers and compatible machines.   
					While selecting the other host interfaces, these selections don’t perform the above functions for you.   
					Please check the actual Caps Lock state in use while software application is running. If the Caps Lock state is off, select “Caps Lock Off” state, then FuzzyScan will   
					perform normal data transmission. If the Caps Lock state is on, select “Caps Lock On” state. Select “Auto Detect”, FuzzyScan will perform special transmission   
					handshaking without changing the status of Caps Lock switch.   
					31   
				Configure Your FuzzyScan   
					Keyboard Interface Control   
					♦ Delay Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Intermessage Delay   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					Intercharacter Delay   
					Interfunction Delay   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢂ 
					ꢂ 
					Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.   
					Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data   
					transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)   
					various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two   
					parameters.   
					ꢂ 
					Interfunction Delay is a time delay between the transmission of each segment of the message string.   
					32   
				Configure Your FuzzyScan   
					Keyboard Interface Control   
					♦ Emulation Setting & Upper/Lower Case Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Function Key Emulation   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					Enable ASCII 00-31 code as keyboard function code output   
					Ctrl-Output   
					0 
					1 
					Refer to Appendix – Keyboard Function Code Table for details.   
					ꢁ 
					SS   
					SS   
					Disable key pad emulation   
					0 
					1 
					Key Pad Emulation   
					Upper/Lower Case   
					Enable numeric output as key pad (Num Lock On) output   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					Normal case (neglect the upper/lower case control)   
					0 
					1 
					2 
					3 
					Inverse case (change all characters output to inverse case)   
					Upper case (force all characters output as upper case)   
					Lower case (force all characters output as lower case)   
					33   
				Configure Your FuzzyScan   
					Serial Interface Control   
					♦ Record Suffix, Preamble ,Postamble Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					STX/ETX Control   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					Disable STX/ETX transmission   
					Enable STX/ETX transmission   
					0 
					1 
					STX/ETX are two characters used to indicate the starting and ending of the total   
					data frame transmitted via serial interface.   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					MS   
					None   
					CR (0DH)   
					LF (0AH)   
					CRLF (0D0AH)   
					TAB (09H)   
					0 
					1 
					2 
					3 
					4 
					5 
					Record Suffix   
					ꢁ 
					SPACE (20H)   
					User defined character (1 character)   
					6, (00-7F)   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					Preamble   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					Postamble   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢂ 
					Serial Interface Message String (RS232, USB COM) :   
					STX   
					Preamble   
					Data Length   
					2-3 digits   
					Prefix Symbol ID Scanned Data   
					Suffix Symbol ID   
					Postamble   
					ETX   
					Record Suffix   
					1 character   
					1 character   
					1-15 characters   
					1 or 2 characters Variable length 1 or 2 characters 1-15 characters   
					1 character   
					34   
				Configure Your FuzzyScan   
					Serial Interface Control   
					♦ Delay Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Intermessage Delay   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					Intercharacter Delay   
					Interfunction Delay   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					(2 digits)   
					1-99 (x5) msec.   
					Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate   
					this selection automatically.   
					ꢂ 
					ꢂ 
					Intermessage Delay is a time delay between messages output by FuzzyScan. Increasing this delay will help host applications process the incoming data on time.   
					Intercharacter Delay is a time delay between data characters output by FuzzyScan. These two parameters are used to synchronize data communication when : 1) the data   
					transmission speed is too fast, characters may be skipped; 2) multitasking operation system or host computers in a network may slow down the keyboard handling; 3)   
					various notebook or desktop PC systems require different timing parameter settings. Please always add one extra unit as safety margin when adjusting these two   
					parameters.   
					ꢂ 
					Interfunction Delay is a time delay between the transmission of each segment of the message string.   
					35   
				Configure Your FuzzyScan   
					Serial Interface Control   
					♦ Protocol, ACK/NAK Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Handshaking Protocol   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					None (free running mode)   
					0 
					1 
					2 
					3 
					RTS/CTS (hardware handshaking)   
					ACK/NAK (software handshaking)   
					Xon/Xoff (software handshaking)   
					ꢁ 
					SS   
					SS   
					3 times   
					FIN   
					(3 digits)   
					NAK Retry Count   
					ACK Indication   
					0~255 times   
					SS   
					SS   
					SS   
					SS   
					Disable ACK Time-out Indication   
					Enable ACK Time-out Indication   
					Disable ACK Indication   
					Enable ACK Indication   
					0 
					1 
					2 
					3 
					ꢁ 
					ꢁ 
					ꢂ 
					ꢂ 
					USB COM doesn’t support RTS/CTS handshaking protocol.   
					When the ACK/NAK Software Handshaking option is selected, the FuzzyScan waits for an ACK (acknowledge) or NAK (not acknowledge) from the host computer after   
					each data transmission. If the NAK is received, FuzzyScan will re-send the data until receiving ACK.’   
					ꢂ 
					NAK Retry Count   
					After transmitting data, the scanner expects a NAK response from the host up to the preset “Serial Response Time-out”. If the scanner doesn’t get a response, the scanner   
					will issue an error indication and discard the data. When a NAK is received, the scanner transmits the same data again and waits for either an ACK or NAK. The scanner   
					issues an error indication and discards the data under following two conditions:   
					1) After preset NAK retry counts is received within the preset serial response time-out.   
					2) If the preset time-out is up but the preset NAK retry counts haven’t come to the end.   
					The default retry counts are three times. If you program “0 time”, the scanner won’t resend the data to the host when the scanner receives a NAK. The scanner will discard   
					the data. If you program “255 times”, the scanner can receive unlimited NAKs from the host within the pre-set serial response time-out.   
					This function is not available for batch mode. When you enable this function in on-line mode, the out-of-range function will be disable automatically.   
					ꢂ 
					ACK Indication:   
					Disable: There’s neither LED nor beeping indication for this setting.   
					Enable: There’s a specific LED and beeping indication for this setting.   
					36   
				Configure Your FuzzyScan   
					Serial Interface Control   
					♦Time Out Setting, Baud Rate, Data Frame ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Serial Response Time-out   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					3 seconds   
					4 seconds   
					5 seconds   
					8 seconds   
					10 seconds   
					15 seconds   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					200 mseconds   
					500 mseconds   
					800 mseconds   
					1 second   
					ꢁ 
					2 seconds   
					SS   
					SS   
					SS   
					SS   
					38.4K BPS   
					19.2K BPS   
					2400 BPS   
					1200 BPS   
					57.6K BPS   
					115.2K BPS   
					0 
					1 
					2 
					3 
					4 
					5 
					8 
					9 
					Baud Rate (BPS)   
					Data Frame   
					ꢁ 
					9600 BPS   
					4800 BPS   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					8, None, 1   
					8, Odd, 1   
					8, Even, 1   
					8, Space, 1   
					8, Mark, 1   
					8, None, 2   
					7, Odd, 1   
					7, Space, 1   
					7, Mark, 1   
					7, None, 2   
					7, Odd, 2   
					7, Even, 2   
					7, Space, 2   
					7, Mark, 2   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					A 
					B 
					C 
					D 
					E 
					7, Even, 1   
					ꢂ 
					ꢂ 
					When the RTS/CTS Hardware Handshaking option is selected, the RTS (request to send) and CTS (clear to send) signals will be issued before normal data   
					communication. This option is very helpful to ensure the reliability of data communication.   
					The Serial Response Time-out is a pre-defined delay time for FuzzyScan to wait for handshaking, acknowledgment or non-acknowledgment from the host computer.   
					37   
				Configure Your FuzzyScan   
					Wand/Laser Emulation Control   
					♦ Code 39/Code 128 Emulation ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Code 39/Code 128 Emulation   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable standard Code 39 emulation   
					0 
					1 
					2 
					3 
					4 
					ꢁ 
					Enable standard Code 39 skip emulation   
					Enable standard Code 39 replace emulation   
					Enable Full ASCII Code 39 emulation   
					Enable Code 128 emulation   
					ꢂ 
					ꢂ 
					[ Code 39 Skip] : When this option is selected, all scanned data will be translated as Standard Code 39 wand/laser emulation output. If any lower case characters are read,   
					they will be translated to upper case characters. Any other characters that are not available in Code 39 symbology set will be skipped.   
					[ Code 39 Replace] : Any character not normally available in the standard Code 39 symbology set, will be translated as Space.   
					38   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Operation Mode Setting ♦   
					PROGRAM   
					Family Code Selection   
					Operation Mode   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					Low Power mode   
					Force mode   
					Toggle mode   
					Diagnostic mode   
					Level mode   
					L680/L780 laser imagers don’t support:   
					Flash/ Force/ Toggle/ Diagnostic mode.   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					ꢁ 
					Trigger mode   
					Presentation mode   
					Alternative mode   
					Flash mode   
					ꢁ 
					SS   
					SS   
					SS   
					Presentation mode   
					Flash mode   
					Force mode   
					0 
					1 
					2 
					Presentation Control   
					L680/L780 laser imagers don’t support this function.   
					ꢂ 
					ꢂ 
					ꢂ 
					Low Power Mode (Low Power Triggering) The scanner goes into idle state after scanning the bar code. You must press the trigger to wake up the scanner for operation.   
					It is very helpful for mobile data collection and application, which are concerned with power saving.   
					Trigger Mode (External Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner   
					before scanning the bar code.   
					Presentation Mode (Auto Detection) Presentation mode uses ambient light to detect the bar codes. The light source is off until the scanner detects an image which is   
					similar to a barcode. Then the light source turns on automatically to read the bar code. If the light level in the room is not high enough, Presentation Mode may not work   
					properly. You can choose different level of “Presentation Sensitivity” to meet your application (Please refer to the setting of “Presentation Sensitivity”).   
					Alternative Mode (Periodic Power Off) The scanner keeps the light source of the scanner turned on till the pre-defined light source on time is up. After the scanner turns   
					off the light source, you must press the trigger to turn on the light source again. After each good read, the timer counter of “Light Source on Time” is reset. You do not have   
					to press the trigger frequently, it is very convenient for multiple scanning.   
					ꢂ 
					ꢂ 
					ꢂ 
					ꢂ 
					ꢂ 
					ꢂ 
					Flash Mode (Pulse Driven Reading) The scanner flashes the light source of the scanner without using the trigger. If the scanner detects an image which is similar to a bar   
					code, the scanner forces on the light source automatically and scans the bar code. Flash Duty Cycle adjustment can change the frequency of the blinking.   
					Force Mode (Continued Power On) The light source of the scanner is forced on for continued operation without pressing the trigger switch. This mode is convenient for   
					high speed bar code reading.   
					Toggle Mode (Repeat Reading) The toggle mode is very similar to the Alternative Mode but without the pre-defined light source on time concern. You must press the   
					trigger to turn on the light source of the scanner to scan. The scanner keeps the light source turned on until you press the trigger again.   
					Diagnostic Mode (Test Reading) This operation mode is specifically designed for diagnostic purposes. When this operation mode is selected, the light source of the   
					scanner is force on without regard for other programmable parameters, such as reread delay, redundancy, and so forth.   
					Level Mode (Auto Power Off) When this operation mode is selected, the scanner continues to turn on the light source of the scanner before a good read or pre-defined   
					“Light Source on Time”. If the scanner decodes a bar code successfully, it turns off the light source immediately. After the scanner turns off the light source, you must press   
					the trigger to turn on the light source again. If there is no scanning operation performed during the pre-defined light source on time, the scanner enters the idle state after   
					the pre-defined light source on time is up.   
					ꢂ 
					ꢂ 
					Presentation Control When the scanner is placed on SmartStand, the scanner will be switched from hand-held scanning to hands free scanning automatically. Three   
					hands scanning modes are available. You are recommended to use flash mode or force mode while under insufficient ambient light.   
					Only Low power mode, Trigger mode, Presentation mode and Level mode are available for FuzzyScan Laser model.   
					39   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Buzzer, Indicator, Vibrator, Inverse Reading ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Buzzer Tone Adjust   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Buzzer tone – mute   
					Buzzer tone – low   
					Buzzer tone – medium   
					Buzzer tone – high   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					ꢁ 
					Buzzer tone - extremely high   
					ꢁ 
					Power-on beep   
					No power-on beep   
					SS   
					SS   
					SS   
					Disable (LED off)   
					0 
					1 
					2 
					Power On Indicator   
					Good Read Indicator   
					Vibrator Control   
					ꢁ 
					LED steady on   
					LED flash   
					SS   
					SS   
					Disable   
					0 
					1 
					ꢁ 
					ꢁ 
					Enable   
					SS   
					SS   
					Disable   
					Enable   
					0 
					1 
					Optional function, only available for vibrator model.   
					ꢁ 
					SS   
					SS   
					Disable   
					Enable   
					0 
					1 
					Inverse Reading   
					40   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Dollar Sign, Redundancy, Scan Rate Control♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Dollar Sign Control   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					Dollar sign output as “ $ “   
					0 
					1 
					2 
					3 
					4 
					Dollar sign output as “   
					“ 
					Dollar sign output as “ € “   
					Dollar sign output as “ £ “   
					Dollar sign output as “ ¢ “   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					0 
					1 
					2 
					3 
					4 
					5 
					Redundancy   
					ꢁ 
					Level 1   
					Level 2   
					Level 3   
					Level 4   
					Level 5   
					To prevent potential miss reading.   
					ꢁ 
					SS   
					SS   
					Dynamic   
					Fixed   
					0 
					1 
					Scan Rate Control   
					ꢂ 
					ꢂ 
					The Redundancy is the number of times the same bar code label has to be decoded before it is transmitted.   
					Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on   
					the move. But this may impact to the reading distance.   
					41   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Flash Duty Cycle, Delay Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Flash Duty Cycle   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					1/2 duty cycle   
					2/3 duty cycle   
					3/4 duty cycle   
					4/5 duty cycle   
					0 
					1 
					2 
					3 
					L680/L780 laser imagers don’t support this function.   
					Reread Delay   
					(DoubleScan Verification)   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable   
					Immediate time out   
					Short time out   
					Medium time out   
					Long time out   
					Force verification   
					0 
					1 
					2 
					3 
					4 
					5 
					ꢁ 
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					None   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					Good Read Delay   
					200 msec.   
					500 msec.   
					1 sec.   
					1.5 sec.   
					2 sec.   
					3 sec.   
					ꢂ 
					ꢂ 
					The Flash Duty Cycle is designed to control the flashing frequency of the light source.   
					The Reread Delay (Double Scan Verification) is designed to inhibit FuzzyScan from reading the same bar code label twice in pre-defined short duration. Force Verification   
					will not allow reading of the same bar code twice.   
					ꢂ 
					This Good Read Delay is the minimum amount of time before the imager can read another bar code.   
					42   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Time-out Setting, Good Read Duration ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Light Source On Time   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					Medium   
					SS   
					SS   
					SS   
					SS   
					Short   
					0 
					1 
					2 
					3 
					Long   
					Extremely long   
					ꢁ 
					Medium   
					SS   
					SS   
					SS   
					SS   
					SS   
					Short   
					0 
					1 
					2 
					3 
					4 
					Hands Free Time-out   
					Good Read Duration   
					Long   
					Extremely long   
					Disable   
					SS   
					SS   
					SS   
					SS   
					SS   
					Short   
					0 
					1 
					2 
					3 
					4 
					ꢁ 
					Medium   
					Long   
					Extremely long   
					Extremely short   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					1 sec   
					0 
					1 
					2 
					3 
					4 
					5 
					Time Delay to Low Power Mode   
					3 secs   
					5 secs   
					7 secs   
					9 secs   
					ꢁ 
					Immediate   
					ꢂ 
					ꢂ 
					The Light Source On Time is a pre-defined light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on   
					till the pre-defined light source on time is up. You can adjust this parameter to meet your own application requirement.   
					The Presentation Mode, Force Mode and Flash Mode are referred to as “hands free” mode. The hands free mode will be automatically changed to manual trigger mode   
					when you press the trigger. You can remain the scanner in manual trigger mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any   
					trigger operation), the imager will revert to the original hands free mode.   
					ꢂ 
					The Time Delay to Low Power Mode sets the time for scanner to enter low power mode after any scanning activity. This setting is only available for the scanner is in low   
					power mode.   
					43   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Presentation Scanning Setting , Trigger Control♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					SmartStand Power Off Timeout   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					SS   
					SS   
					3 mins   
					5 mins   
					0 
					1 
					2 
					10 mins   
					Only available for FuuzzyScan Laser model   
					Disable   
					SS   
					SS   
					0 
					1 
					Presentation Auto-sense   
					Presentation Sensitivity   
					Trigger Control   
					ꢁ 
					Enable   
					SS   
					SS   
					SS   
					SS   
					SS   
					Level 1   
					Level 2   
					Level 3   
					Level 4   
					Level 5   
					Level 6   
					Level 7   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					ꢁ 
					SS   
					SS   
					SS   
					Enable left trigger, disable right trigger   
					Enable right trigger, disable left trigger   
					0 
					1 
					2 
					ꢁ 
					Enable left and right triggers   
					Only available for FuzzyScan F460/F468   
					ꢂ 
					The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on   
					SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be   
					off when the pre-defined duration is up.   
					ꢂ 
					ꢂ 
					When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the   
					SmartStand.   
					The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting   
					the barcode.   
					44   
				Configure Your FuzzyScan   
					Operation Control   
					♦ Laser Aiming Control♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Laser Aiming Control   
					P.C   
					Parameter Selection   
					Option Code   
					SS   
					SS   
					Disable   
					Enable   
					0 
					1 
					Only available for L series laser imaging scanner.   
					You can disable or enable laser aiming line when you scan PDF barcode.   
					ꢂ 
					45   
				Configure Your FuzzyScan   
					Condensed DataWizard   
					♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦   
					PROGRAM   
					Family Code Selection   
					Preamble   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢁ 
					SS   
					MS   
					None   
					FIN   
					[00-7F], [FIN]   
					Postamble   
					1-15 characters   
					Maximum 15-character input; scan “FIN” to terminate this selection.   
					ꢁ 
					SS   
					SS   
					Disable   
					0 
					1 
					Data Length Transmission   
					Symbology ID Transmission   
					Enable 2 digits data length transmission   
					If data length exceeds 99, 3-digit data length will be transmitted.   
					ꢁ 
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					SS   
					Disable symbology ID transmission   
					Enable prefix symbology ID transmission   
					Enable suffix symbology ID transmission   
					Enable both prefix and suffix symbology ID transmission   
					Enable prefix AIM symbology ID transmission   
					Enable suffix AIM symbology ID transmission   
					Enable both prefix and suffix AIM symbology ID transmission   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					ꢂ 
					DataWizard is the most powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code readers. Through DataWizard,   
					you can process the scanned data prior the transmissions in many ways as: Insert, Delete, Match, Verify, Replace, Reorganize, and Repeat Transmission. It will help   
					you to arrange the transmission of scanned data to any specific format without software modification.   
					ꢂ 
					ꢂ 
					Due to the resources used by this system, Full-feature DataWizard is only supported by PowerTool. Through the PowerTool, all settings and configurations can be done   
					on-screen, under Windows 95/98/NT/2000/XP environment.   
					A Condensed Version DataWizard is provided by each FuzzyScan series. Through this menu, the condensed DataWizard can be utilized via bar code menu readings with   
					ease.   
					ꢂ 
					ꢂ 
					Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.   
					If you have any problem to use DataWizard, please refer to following pages for details and consult your local FuzzyScan vendor or our web site for any assistance.   
					46   
				Configure Your FuzzyScan   
					Condensed DataWizard   
					♦ Data Formatter Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Formatter Control   
					P.C   
					Parameter Selection   
					Option Code   
					2nd Option Code   
					ꢁ 
					SS   
					MS   
					MS   
					Disable   
					FIN   
					(2 digits)   
					00   
					Select one bar code symbology   
					Select all bar code symbologies   
					automatic termination   
					automatic termination   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					1st Insertion   
					2nd Insertion   
					3rd Insertion   
					4th Insertion   
					[1-3 characters], [FIN]   
					[1-3 characters], [FIN]   
					[1-3 characters], [FIN]   
					2-digits identified position; max. 3 insertion characters   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits identified position; max. 3 insertion characters   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits identified position; max. 3 insertion characters   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					[1-3 characters], [FIN]   
					2-digits identified position; max. 3 insertion characters   
					position   
					ꢂ 
					ꢂ 
					The Data Formatter is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code   
					symbologies for formatter control, and provides Multiple Position Insertion and Multiple Character Insertion (max three characters) in the identified position.   
					While the Data Formatter is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.   
					All of the above programmable parameters perform the same function depending on your setting.   
					ꢂ 
					ꢂ 
					Regarding the “Bar Code Selection” and “Position Calculation” of data formatter, please refer to page 45 for details.   
					Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.   
					47   
				Configure Your FuzzyScan   
					Condensed DataWizard   
					♦ Data Verifier Setting ♦   
					PROGRAM   
					Family Code Selection   
					Verifier Control   
					F_DEFAULT   
					P.C   
					Parameter Selection   
					Option Code   
					2nd Option Code   
					ꢁ 
					SS   
					MS   
					MS   
					Disable   
					FIN   
					(2 digits)   
					00   
					Select one bar code symbology   
					Select all bar code symbologies   
					automatic termination   
					automatic termination   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					Identified Data Length   
					1st Identified Character   
					2nd Identified Character   
					3rd Identified Character   
					Determine the identified data length for verification.   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					[00-7F]   
					[00-7F]   
					[00-7F]   
					2-digits checking position; 1 identified character   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits checking position; 1 identified character   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits checking position; 1 identified character   
					position   
					ꢂ 
					ꢂ 
					The Data Verifier is used to provide advanced verification for error-free scanning and to work as an Embedded Data Transmitting Filter.   
					All data must conform to the Identified Bar Code Symbologies, Identified Data Length, and one to three Identified Characters in the checking position. Otherwise, the   
					FuzzyScan will not transmit the data to the host computers or terminals, but will instead issue 3 long beeps for verification error and skip the scanned data.   
					ꢂ 
					ꢂ 
					ꢂ 
					The Data Verifier checks only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.   
					Regarding the “Bar Code Selection” and “Position Calculation” of Data Verifier, please refer to page 45 for details.   
					Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.   
					48   
				Configure Your FuzzyScan   
					Condensed DataWizard   
					♦ Data Replacer Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Replacer Control   
					P.C   
					Parameter Selection   
					Option Code   
					2nd Option Code   
					ꢁ 
					SS   
					MS   
					MS   
					Disable   
					FIN   
					(2 digits)   
					00   
					Select one bar code symbology   
					Select all bar code symbologies   
					automatic termination   
					automatic termination   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					1st Replacement   
					2nd Replacement   
					3rd Replacement   
					[00-7F]   
					[00-7F]   
					[00-7F]   
					2-digits identified position; 1 replacement character   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits identified position; 1 replacement character   
					position   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					2-digits identified position; 1 replacement character   
					position   
					ꢂ 
					ꢂ 
					The Data Replacer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code   
					symbologies for replacer control, and provides Multiple Position Replacement in the identified position.   
					All data must conform to the Identified Bar Code Symbologies, and one to three Identified Characters in the identified position While the Data Replacer is enabled, it   
					arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record Suffix.   
					ꢂ 
					ꢂ 
					Regarding the “Bar Code Selection” and “Position Calculation” of Data Replacer, please refer to page 45 for details.   
					Please note that all “Character” input should be referred to the ASCII/HEX Table listed in Appendix to find matched HEX value.   
					49   
				Configure Your FuzzyScan   
					Condensed DataWizard   
					♦ Data Organizer Setting ♦   
					PROGRAM   
					F_DEFAULT   
					Family Code Selection   
					Organizer Control   
					P.C   
					Parameter Selection   
					Option Code   
					2nd Option Code   
					ꢁ 
					SS   
					MS   
					MS   
					Disable   
					FIN   
					(2 digits)   
					00   
					Select one bar code symbology   
					Select all bar code symbologies   
					automatic termination   
					automatic termination   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					1st Organization   
					2nd Organization   
					ꢁ 
					0 (Forward)   
					1 (Backward)   
					2-digits identified position;   
					Forward/backward data transmission setting   
					position   
					direction   
					ꢁ 
					SS   
					DS   
					Disable   
					Enable   
					FIN   
					(2 digits)   
					ꢁ 
					0 (Forward)   
					1 (Backward)   
					2-digits identified position;   
					Forward/backward data transmission setting   
					position   
					direction   
					ꢁ 
					SS   
					DS   
					Transmitted data excluded the data of identified position   
					Transmitted data included the data of identified position   
					0 
					1 
					Include/Exclude Control   
					ꢂ 
					ꢂ 
					The Data Organizer is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired bar code   
					symbologies for organizer control, and provides maximum two identified positions to send the data forward or backward. It also allows you to control the transmitted data   
					including or excluding the data of identification position. Please refer to the application example listed in page 45 for details.   
					While the Data Organizer is enabled, it arranges only scanned data without Preamble, Postamble, STX, ETX, Data Length, Prefix/Suffix Symbology ID or Record   
					Suffix.   
					ꢂ 
					ꢂ 
					Regarding the “Bar Code Selection” and “Position Calculation” of Data Organizer, please refer to page 45 for details.   
					Please note that all “Character” input should be referred to the ASCII/HEX Table.   
					50   
				Configure Your FuzzyScan   
					[Data Verifier, Data Replacer, Data Organizer]   
					Select a Bar Code Symbology   
					If there is a 11-character data string, please refer to the   
					following to calculate the actual position for identification.   
					You can select one or all types of bar code symbologies to   
					use Condensed DataWizard for advanced transmission   
					arrangement. If you scan “00” to select all types, the   
					FuzzyScan will arrange all incoming data to meet your   
					pre-defined format. If you want to select only one type bar   
					code, please select one of the option code listed below.   
					X 
					X 
					X 
					X 
					X 
					X 
					X 
					X 
					X 
					X 
					X 
					00   
					01   
					02   
					03   
					04   
					05   
					06   
					07   
					08   
					09   
					10   
					Application Example   
					Code 128 : 01   
					EAN-8 : 05   
					Code 93 : 09   
					If your bar code label is a 16-digit Interleaved 2 of 5 which   
					includes the information of 6-digit date code, 6-digit serial   
					number and 4-digit unit price, you want the FuzzyScan do   
					the following for you without software modification:   
					UCC/EAN 128 : 31   
					UPC-A : 02   
					EAN-8 with 2 supple : 35   
					EAN-8 with 5 supple.: 45   
					Codabar/NW-7 : 06   
					Code 39 : 07   
					Code 11 : 10   
					MSI/Plessey : 11   
					UK/Plessey : 12   
					Telepen : 13   
					UPC-A with 2 supple.: 32   
					UPC-A with 5 supple.: 42   
					UPC-E : 03   
					Code 32 : 37   
					GS1 Data Bar : 14   
					IATA : 15   
					ꢂ Apply only Interleaved 2 of 5 to the condensed   
					UPC-E with 2 supple.: 33   
					UPC-E with 5 supple.: 43   
					EAN-13 : 04   
					Trioptic Code 39: 47   
					Matrix 2 of 5 : 38   
					Interleaved 2 of 5 : 48   
					DataWizard.   
					Coupon Code : 16   
					PDF417/Micro PDF417: 22   
					Codablock: 23   
					ꢂ Check bar code is actually with 16-digit length.   
					EAN-13 with 2 supple. : 34 China Postal Code : 58   
					EAN-13 with 5 supple. : 44 German Postal Code : 68   
					ꢂ Allow bar code output whose date code is leading with   
					Korea Post Code: 26   
					“9”.   
					Position Calculation   
					[Data Formatter]   
					ꢂ Three outputs with “TAB” suffix.   
					ꢂ The date code output should skip “9” and replaced it by   
					“A”.   
					If there is a 5-character input data string, refer to the following   
					to calculate the actual position for insertion:   
					ꢂ The serial number output should be led with “SN”.   
					X 
					X 
					X 
					X 
					X 
					ꢂ The unit price output should be skipped the first 2   
					00   
					01   
					02   
					03   
					04   
					05   
					digits.   
					ꢂ Test Bar Code : 9 8 1 0 2 5 1 2 3 4 5 6 9 8 7 6   
					ꢂ Actual Output : A81025[TAB]SN123456[TAB]76[TAB]   
					51   
				Configure Your FuzzyScan   
					Programming Procedure   
					[Data Verifier]   
					[Data Replacer]   
					ꢂ Scan “Program” to enter the programming mode.   
					ꢂ Scan “Replacer Control” and set bar code symbology   
					to “48”.   
					ꢂ Scan “Verifier Control” and set bar code symbology to “48”   
					(Interleaved 2 of 5).   
					ꢂ 
					Scan “1st Replacement” and set the identified position   
					to “00”, then replaced character to “41” (Hex Code of   
					ꢂ Scan “Identified Data Length” and set the length to “16”.   
					A).   
					ꢂ Scan “1st Identified Character” and set the identified   
					position to “00”, then set the identified character to “39”   
					(Hex Code of 9).   
					[Data Organizer]   
					ꢂ Scan “Organizer Control” and set bar code symbology   
					to “48”.   
					[Data Formatter]   
					ꢂ Scan “Formatter Control” and set bar code symbology to ꢂ Scan “1st Organization” and set the identified position   
					“48”. to “16”, then set the data transmission to “0” (forward).   
					ꢂ Scan 1st Insertion” and set the identified position to “06”, ꢂ Scan “2nd Organization” and set the identified position   
					then inserted characters to “09” (Hex Code of TAB), “53”   
					(Hex Code of S), “4E” (Hex Code of N).   
					to “17”, then set the data transmission to “1”   
					(backward).   
					ꢂ Scan “2nd Insertion” and set the identified position to “12”,   
					then inserted character to “09”. In the final, you must scan   
					“FIN” (Finish) code to terminate this selection.   
					ꢂ 
					Scan “END” (Exit) to terminate the programming.   
					[Important Notice]   
					ꢂ 
					Scan “3rd Insertion” and set the identified position to “16”,   
					then inserted character to “09”. In the final, you must scan   
					“FIN” (Finish) code to terminate this selection.   
					Please note that Condensed DataWizard will follow the   
					preset working flow as below:   
					Verifier   
					ꢀ 
					Formatter   
					ꢀ 
					Replacer   
					ꢀ 
					Organizer   
					So when you set the identified position in Data Organizer,   
					you must consider the inserted data which you already set   
					via Data Formatter.   
					52   
				Appendix   
					Symbology ID Table   
					Each AIM Code Identifier contains the three-character string ]cm where:   
					] = Flag Character   
					c = Code Character   
					m = Modifier Character   
					Cino ID   
					AIM ID   
					Cino ID   
					AIM ID   
					Code Family   
					Primary Format   
					Code Family   
					Primary Format   
					Code   
					Code   
					Modified   
					Code   
					Code   
					Modified   
					Character   
					Character   
					Character   
					Character   
					Character   
					Character   
					UPC-A   
					m 
					1 
					EAN/JAN-8   
					4 
					1 
					A 
					E 
					N 
					F 
					E 
					UPC-A with 2 supple.   
					UPC-A with 5 supple.   
					UPC-E   
					EAN/JAN-8 with 2 supple.   
					EAN/JAN-8 with 5 supple.   
					EAN/JAN-13   
					2 
					2 
					E 
					m 
					1 
					m 
					1 
					UPC   
					EAN/JAN   
					E 
					UPC-E with 2 supple.   
					UPC-E with 5 supple.   
					EAN/JAN-13 with 2 supple.   
					EAN/JAN-13 with 5 supple.   
					2 
					2 
					Example: A UPC-A bar code 012345678950 with 2 supplement 12 is   
					transmitted as ]E0012345678950]E112   
					Example: A EAN/JAN-8 bar code 49123562 with 5 supplement 12345 is   
					transmitted as ]E449123562]E212345   
					Code 128   
					B 
					C 
					D 
					I 
					m 
					1 
					Code 93   
					Code 93   
					H 
					P 
					R 
					S 
					T 
					G 
					H 
					M 
					P 
					m 
					m 
					m 
					0 
					Code 128   
					Codabar   
					C 
					GS1-128   
					Code 11   
					Code 11   
					Codabar/NW-7   
					Standard/Industrial 2 of 5   
					Matrix 2 of 5   
					F 
					S 
					X 
					I 
					m 
					0 
					MSI/Plessey   
					UK/Plessey   
					Telepen   
					MSI/Plessey   
					UK/Plessey   
					Telepen   
					K 
					J 
					0 
					B 
					m 
					Interleaved 2 of 5   
					m 
					GS1 DataBar GS1 Databar   
					Code 25   
					X 
					e 
					0 
					Composite   
					Composite Code   
					Code 39   
					China Postal Code   
					L 
					X 
					0 
					G 
					W 
					G 
					V 
					A 
					X 
					A 
					L 
					m 
					0 
					0 
					0 
					0 
					0 
					Code 39   
					German Postal Code   
					IATA   
					M 
					O 
					Z 
					I 
					3 
					Code 39 Trioptic   
					Code 32   
					IATA   
					R 
					m 
					UCC Coupon Code   
					PDF417   
					PDF417/Micro PDF417   
					Codablock F   
					Example : A UPC-A 512345678900 + GS1-128 81010123451297 bar   
					code is transmitted as]E0512345678900]C181010123451297   
					Example: A EAN-13 9923456789019 + GS1-128 81010123451297 bar   
					code is transmitted as ]E09923456789019]C181010123451297   
					Codablock   
					Korea Post   
					Y 
					O 
					X 
					UCC Coupon   
					Korea Post Code   
					a 
					Remark: Above examples are given for the transmission of AIM ID.   
					53   
				Appendix   
					Keyboard Function Code Table   
					No.   
					00   
					01   
					02   
					03   
					04   
					05   
					06   
					07   
					08   
					09   
					10   
					11   
					ANSI   
					NUL   
					SOH   
					STX   
					ETX   
					EOT   
					ENQ   
					ACK   
					BEL   
					BS   
					ASCII   
					00H   
					01H   
					02H   
					03H   
					04H   
					05H   
					06H   
					07H   
					08H   
					09H   
					0AH   
					0BH   
					0CH   
					0DH   
					0EH   
					0FH   
					Key Function   
					No.   
					16   
					17   
					18   
					19   
					20   
					21   
					22   
					23   
					24   
					25   
					26   
					27   
					28   
					29   
					30   
					31   
					ANSI   
					DLE   
					DC1   
					DC2   
					DC3   
					DC4   
					NAK   
					SYN   
					ETB   
					CAN   
					EM   
					ASCII   
					10H   
					11H   
					Key Function   
					RESERVED   
					CTRL (Left)   
					ALT (Left)   
					SHIFT   
					F7   
					F8   
					12H   
					13H   
					14H   
					15H   
					16H   
					17H   
					18H   
					19H   
					1AH   
					1BH   
					1CH   
					1DH   
					1EH   
					1FH   
					F9   
					F10   
					F11   
					F12   
					CAPS LOCK   
					NUM LOCK   
					ESC   
					INS (Insert) (Edit)   
					DEL (Delete) (Edit)   
					HOME (Edit)   
					F1   
					BACK SPACE   
					HT   
					TAB   
					END (Edit)   
					LF   
					F2   
					SUB   
					ESC   
					FS   
					PAGE UP (Edit)   
					PAGE DOWN (Edit)   
					UP (Edit)   
					VT   
					F3   
					12   
					13   
					14   
					15   
					FF   
					F4   
					CR   
					ENTER (CR)   
					GS   
					DOWN (Edit)   
					LEFT (Edit)   
					SO   
					F5   
					F6   
					RS   
					SI   
					US   
					RIGHT (Edit)   
					To emulate the keyboard function key input for user definable parameters, user must configure actual content using the   
					Reserved ASCII 0 – 31 characters, and also Enable the “Function Key Emulation”. Otherwise, the Ctrl output will be done   
					by the scanner. Please refer to the above Keyboard Function Code Table which is for IBM PC/XT/AT, PS/2, PS/VP,   
					COMPAQ PC, HP Vectra PC, Notebook PC, APPLE and PowerMac, and WYSE PC Enhanced or fully compatible machines.   
					54   
				Appendix   
					ASCII Input Shortcut   
					To configure the user definable parameters of FuzzyScan via   
					programming menu, FuzzyScan will ask you to scan your   
					desired ASCII value in HEX form. You have to refer to the   
					“HEX/ASCII Table” for details.   
					HEX/ASCII Reference Table   
					H 
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					L 
					0 
					1 
					NUL   
					SOH   
					STX   
					ETX   
					EOT   
					ENQ   
					ACK   
					BEL   
					BS   
					DLE SPACE   
					0 
					1 
					2 
					3 
					4 
					5 
					6 
					7 
					8 
					9 
					: 
					@ 
					A 
					B 
					C 
					D 
					E 
					F 
					P 
					Q 
					R 
					S 
					T 
					U 
					V 
					W 
					X 
					Y 
					Z 
					[ 
					` 
					a 
					b 
					c 
					d 
					e 
					f 
					p 
					DC1   
					DC2   
					DC3   
					DC4   
					NAK   
					SYN   
					ETB   
					CAN   
					EM   
					! 
					" 
					q 
					Example:   
					2 
					r 
					If you want the scanned data output leading with a Dollar   
					Sign, you have to set the “Preamble” to “$”. The configuration   
					procedure is listed below for reference.   
					3 
					# 
					$ 
					% 
					& 
					' 
					s 
					4 
					t 
					5 
					u 
					ꢂ Scan the system command – PROGRAM listed on page   
					6 
					v 
					3-24 to enter programming mode.   
					7 
					G 
					H 
					I 
					g 
					h 
					i 
					w 
					ꢂ Scan family code – PREAMBLE to select this family.   
					8 
					( 
					x 
					9 
					HT   
					) 
					y 
					ꢂ Refer to the Hex/ASCII Table, you will find the HEX value   
					of “$” is 24.   
					A 
					B 
					C 
					D 
					E 
					F 
					LF   
					SUB   
					ESC   
					FS   
					* 
					J 
					j 
					z 
					VT   
					+ 
					, 
					; 
					K 
					L 
					k 
					l 
					{ 
					ꢂ Scan the option code – 2 listed on the fold out back cover.   
					ꢂ Scan the option code – 4 listed on the fold out back cover.   
					FF   
					< 
					= 
					> 
					? 
					\ 
					| 
					} 
					CR   
					GS   
					- 
					M 
					N 
					O 
					] 
					m 
					n 
					o 
					ꢂ Scan the system command – FIN (Finish) to terminate   
					SO   
					RS   
					. 
					^ 
					~ 
					Preamble setting.   
					SI   
					US   
					/ 
					_ 
					DEL   
					ꢂ Scan the system command – End to exit the programming   
					Example : ASCII “A” → HEX “41”; ASCII “a” → “61”   
					: High Byte of HEX Value   
					mode for normal operation.   
					: Low Byte of HEX Value   
					55   
				Appendix   
					Host Interface Quick Set   
					RS232 Serial   
					PS/2 (DOS/V) KBW Standard Mode   
					ꢁUSB HID Standard Mode   
					Keyboard Replacement   
					PS/2 (DOS/V) KBW Turbo Mode   
					USB HID Turbo Mode   
					USB Com Port Emulation   
					56   
				Appendix   
					Operation Mode Quick Set   
					Low Power (Low power trigger)   
					Force (Continued power on)   
					Toggle (Repeat reading)   
					Diagnostic (Test reading)   
					Alternative (Periodic power off)   
					Flash (Pulse driven reading)   
					Level (Auto power off)   
					ꢁTrigger (External triggering)   
					Presentation (Auto sensing)   
					57   
				Appendix   
					Option Codes   
					0 
					1 
					2 
					3 
					8 
					9 
					4 
					5 
					6 
					7 
					C 
					D 
					E 
					F 
					A 
					B 
					FIN (Finish)   
					END (Exit)   
					58   
				Appendix   
					System Commands   
					PROGRAM   
					(Enter Programming Mode)   
					System Information List   
					(SYSLIST)   
					Save User Default   
					FIN (Finish)   
					PowerTool Host Link   
					User Default   
					END   
					(Exit Programming Mode)   
					Factory Default   
					Master Default   
					ꢂ 
					ꢂ 
					Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.   
					Master Default: After scanning “Master Default” command, the scanner will remain the pre-set parameters of Host Interface Selection, Keyboard Interface   
					Control (except Record Suffix; Preamble; Postamble), Serial Interface Control (except Record Suffix; Preamble; Postamble), and Wand/Laser Emulation   
					Control, the rest of parameters will be returned to default value.   
					ꢂ 
					User Default: After scanning” Save User Default” command, all current parameters will be stored to the flash memory. Once you change the parameter and   
					would like to return to previous setting, please scan “User Default”.   
					59   
				 |