IMC Networks Switch MOR F 632 120 EB82 User Manual

IE-iMcV-E1-Mux/4  
Operation Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
FCC Radio Frequency Interference Statement------------------------------------------------- ii  
Warranty ----------------------------------------------------------------------------------------------- ii  
About the IE-iMcV-E1-Mux/4---------------------------------------------------------------------- 1  
Managed Modules----------------------------------------------------------------------------- 2  
Port Interfaces ---------------------------------------------------------------------------------- 2  
LED Operation ---------------------------------------------------------------------------------------- 5  
10/100BaseT Connector --------------------------------------------------------------------- 5  
E1 RJ-48 Connectors-------------------------------------------------------------------------- 6  
SFP Ports----------------------------------------------------------------------------------------- 6  
Connector Pinout and DIP Switch Assignments ----------------------------------------------- 7  
DIP Switch Assignments---------------------------------------------------------------------- 7  
10/100BaseT Ethernet Mating Connector Pinout--------------------------------------- 8  
E1 Port Mating Connector Pinout---------------------------------------------------------- 8  
RS-232 Port Mating Connector Pinout---------------------------------------------------- 9  
RS-232 Serial Console Port------------------------------------------------------------------ 9  
Installation Instructions-----------------------------------------------------------------------------10  
Configuration Options------------------------------------------------------------------------------11  
Ethernet Line Setup ------------------------------------------------------------------------- 11  
Packet Size------------------------------------------------------------------------------------ 11  
Auto Negotiation----------------------------------------------------------------------------- 11  
Forcing the Speed, Duplex Mode, and Flow Control-------------------------------- 11  
FX LinkLoss and LFPT ----------------------------------------------------------------------- 11  
FX LinkLoss (FXLL)--------------------------------------------------------------------------- 12  
Link Fault Pass-Through (LFPT)------------------------------------------------------------ 12  
E1 Ports Setup-------------------------------------------------------------------------------- 12  
Alarm Level ----------------------------------------------------------------------------------- 12  
Loopback-------------------------------------------------------------------------------------- 13  
Console Screens -------------------------------------------------------------------------------------14  
Login Screen ------------------------------------------------------------------------------------- 14  
Main Menu--------------------------------------------------------------------------------------- 14  
Menu Options-------------------------------------------------------------------------------- 15  
Unit Configuration Screen -------------------------------------------------------------------- 16  
Port Alarm Status Screen ---------------------------------------------------------------------- 16  
SFP Line Status Screen ------------------------------------------------------------------------- 17  
Ethernet Port Configuration Screen --------------------------------------------------------- 18  
Ethernet Port Status Screen ------------------------------------------------------------------- 18  
E1 Port Configuration Screen----------------------------------------------------------------- 19  
E1 Port Status Screen--------------------------------------------------------------------------- 20  
Troubleshooting -------------------------------------------------------------------------------------21  
Fiber Optic Port Verification------------------------------------------------------------------ 22  
E1 Port Verification ----------------------------------------------------------------------------- 23  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Normal Operation ------------------------------------------------------------------------------ 24  
Fiber Optic Cleaning Guidelines------------------------------------------------------------- 25  
Electrostatic Discharge Precautions--------------------------------------------------------------26  
Specifications-----------------------------------------------------------------------------------------27  
Standards/Compliance -----------------------------------------------------------------------------27  
IMC Networks Technical Support----------------------------------------------------------------28  
Definition of Terms/Acronyms--------------------------------------------------------------------29  
Certifications -----------------------------------------------------------------------------------------31  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About the IE-iMcV-E1-Mux/4  
Overview  
The IE-iMcV-E1-Mux/4 is a media converter that transports four independent E1 lines  
over an existing single (or dual, “1+1”) standard 155Mbps-capable fiber optic line  
operating at an effective rate of 150Mbps. One serial link (RS-232) and one Ethernet  
(10/100BaseT) connection are also multiplexed onto the fiber link(s). Each of these  
communication channels is transported end-to-end at full wire speed with very low  
latencies.  
The serial link can be used for extending an independent RS-232 interface to the  
remote POP location for use in managing or controlling other devices at the POP and  
supports any data rate up to 250K baud. In addition, each unit also supports an RS-  
232 console port for local configuration by technical support personnel. Both of  
these serial links are used for end-to-end system management, fault  
detection/isolation and system diagnostics.  
The IE-iMcV-E1-Mux/4 provides fault indications on the E1 and fiber links resulting  
from real-time active faults. The equipment detects both E1 and fiber LOS events as  
well as degraded E1 or fiber lines. The unit will automatically forward AIS signaling to  
the remote unit after detecting an LOS (Loss Of Signal) condition on any incoming E1  
line. Severe receive optical link failures will result in the automatic generation of AIS  
signaling onto the E1 lines connected to the unit receiving the corrupted optical  
signal.  
In addition, CV (Code Violation) errors are detected on all incoming E1 lines and BER  
calculations for the optical line are constantly being performed by circuitry within the  
unit's optical receiver. Error conditions are displayed on the unit’s front panel LED  
indicators and reported to system management software (if equipped) where more  
detailed error information can be displayed on the user’s GUI  
.
Systems equipped with 1+1 fiber redundancy can benefit from the enhanced  
reliability of a protected fiber link and the system’s ability to automatically switch to  
the “best” fiber line should one line become impaired or fail. This automatic  
switchover capability is designed to occur rapidly (<50 milliseconds), minimizing data  
loss and system down time. In addition, automatic switchover can be overridden;  
this allows the end-user to force the unit to receive on a specific optical line if desired  
The IE-iMcV-E1-Mux/4 offers the following features:  
• Four E1 ports on RJ-48 connectors with surge protection  
• One full bandwidth Ethernet 10/100BaseT port  
1+1 protection switching via two SFP-based optical ports  
DDMI supported on SFP ports  
• One end-to-end serial RS-232 port on an RJ-48 connector  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Local CLI management console port on a Mini Jack connector  
• Remote management capability through iMediaChassis series  
AIS generation on signal loss on all E1 interfaces  
SNMP Alarm TRAP reporting in managed chassis  
MDI/MDIX automatic Ethernet port switching  
The IE-iMcV-E1-Mux/4 module is a dual-wide iMcV module.  
Compatible chassis include the following:  
iMediaChassis series  
MediaChassis series  
IE-MediaChassis series  
Product Application  
The IE-iMcV-E1-Mux/4 delivers 4 E1 lines to a customer's site over a protected,  
dedicated fiber line. In addition, one serial RS-232 line and one 10/100BaseT  
Ethernet line can be carried at the same time. All circuits run at full line rates with no  
interaction.  
10/100BaseT  
10/100BaseT  
(1 Port)  
(1 Port)  
ISP Internet  
Customer  
LAN  
E1-Mux  
(Subscriber)  
E1  
(4 Port)  
E1-Mux  
(Network)  
Dedicated  
Fiber  
E1  
(4 port)  
Customer  
PABX  
TDM Network  
PSTN  
Console RS232  
Host  
Remote  
Serial Port  
Console  
Serial Port  
Console  
Dedicated  
Fiber  
Protection  
(1+1)  
Local Far End  
Remote Far End  
Managed Modules  
The IE-iMcV-E1-Mux/4 modules are installed as a Host/Remote pair. Host or Remote  
configuration is selected by an onboard DIP Switch setting. The Host/Remote pair  
can be remotely managed when the HOST is installed in an iMediaChassis with an  
SNMP Management Module.  
Port Interfaces  
A fully-configured IE-iMcV-E1-Mux/4 includes the following ports:  
Four E1 ports on RJ-48 connectors short haul  
One 10/100BaseT twisted pair Ethernet port  
One fiber SFP port (requires SFP/155-ED module for each port)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional SFP port for optical 1+1 protection.  
One Mini Jack serial RS-232 serial console port  
One user serial RS-232 data port (RJ-45)  
The IE-iMcV-E1-Mux/4 is easily configured by using the serial console port  
connection or through an SNMP management application such as iView².  
Console Serial Port Connection  
10/100BaseT  
Connector  
RS-232  
Connector  
E1 RJ-48  
Connectors  
SFP  
Ports  
Console  
The IE-iMcV-E1-Mux/4 includes a console serial port. To establish a link between a  
module's console port and a local PC, connect the Mini Jack to DB9 adapter that is  
included with the IMC module. This RS-232 serial connection provides access to the  
IE-iMcV-E1-Mux/4 module CLI configuration screens. Set the computer/terminal for  
VT-100 emulation 38.4K baud, 8 data bits, 1 stop bit, no parity and no flow  
,
control. Under the VT-100 emulation, set the backspace key to send delete.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
iView² Management Software  
iView² is the IMC Networks management software that features a GUI and gives  
network managers the ability to monitor and control manageable IMC Networks  
products.  
iView² is available in several versions, including WebServer version 3.0, and can also  
function as a snap-in module for HP OpenView Network Node Manager and other  
third party SNMP Management software. For assistance in selecting the right version  
of iView² for your operating system, please visit:  
iView2 supports the following platforms:  
Windows 2000  
Windows XP  
Windows Vista  
Windows 7  
Please see the SNMP Management Module for software configuration options.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED Operation  
10/100BaseT  
Connector  
RS-232  
Connector  
E1 RJ-48  
Connectors  
SFP  
Ports  
The IE-iMcV-E1-Mux/4 features diagnostic LEDs as explained below.  
10/100BaseT Connector  
LNK:  
OFF when port is not linked/connected  
Glows green when link is established  
Blinks green during data activity  
FDX:  
OFF when port is not connected or when running at half-  
duplex  
Glows yellow when port is running at full duplex  
Blinks yellow when collisions occur  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
E1 RJ-48 Connectors  
ALARM:  
OFF during normal operation  
STAT:  
Glows green  
during normal  
operation  
Blinks red+green simultaneously  
when CV errors detected on the E1  
line at far end of the optical line  
Glows red+green when loss of  
service (LOS) is detected, OR  
continuous bit errors are detected  
on the E1 line at far end of the  
optical line  
Blinks red when local CV errors  
detected on E1 line.  
Glows red when LOS detected on  
the local E1 line, OR  
Glows  
red+green when  
out-of-service or  
when the port is  
in a loopback or  
test state  
Glows red when  
the Host to  
Remote fiber  
link(s) is down or  
badly corrupted  
when continuous errors are  
detected on the local E1 line  
SFP Ports  
One model offers two SFP (A and B) ports for 1+1 protection; a  
second model offers one SFP without protection.  
ACT:  
Glows green when the SFP port is the active receive line.  
OFF when the SFP is not the receive line  
Glows red+green when the SFP port is manually forced to  
be the active receive line  
LNK:  
Glows green when there is a valid link  
Glows red when a loss of optical signal occur, LOF, or with  
continuous optical bit errors  
RAI  
:
Off when no remote defects are detected  
Glows red+green when remote LOS or BER detected  
MSA  
:
Off when SFP is not an IMC Networks SFP  
Glows green when no SFP alarms are detected  
Glows red+green when SFP alarms or defects are detected  
at remote end  
Glows red when SFP alarms or misconfigurations are  
detected locally, i.e., when the SFP is missing, or when SFP  
speed is not at 155Mbps  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connector Pinout and DIP Switch Assignments  
DIP Switch Assignments  
A single 10-position DIP Switch is located on the unit to set the configuration. The  
switch positions are defined as follows:  
Switch #  
Function  
Settings  
Factory Default  
1
Host/Remote  
OFF = Host,  
ON = Remote  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
2
3
4
5
6
7
8
9
10  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
Reserved  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
NOTE  
Switch #1 must be set to ON at the Remote location.  
Switches #2 through #10 are reserved for factory use only and must be OFF for  
proper operation.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
10/100BaseT Ethernet Mating Connector Pinout  
The following table lists the pin configuration for the standard RJ-45 Ethernet  
connector.  
Pin  
1
2
3
4
Signal  
Transmit +  
Transmit -  
Receive +  
None  
5
None  
6
7
Receive -  
None  
Pin 1  
8
None  
NOTE  
MDI/MDIX AutoCross function will automatically transpose the Transmit and  
Receive lines if required.  
E1 Port Mating Connector Pinout  
The following table lists the pin configuration for the standard RJ-48 E1 port mating  
connectors.  
Pin  
1
2
Signal  
Receive 1 (Tip in to unit)  
Receive 2 (Ring in to unit)  
None  
3
4
5
6
Transmit 1 (Tip from unit)  
Transmit 2 (Ring from unit)  
None  
7
8
None  
None  
Pin 1  
NOTE  
The pin configuration is consistent with a DTE interface.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
RS-232 Port Mating Connector Pinout  
The following table lists the pin configuration for the RS-232 port mating connector.  
Pin  
1
Signal  
None  
2
None  
3
None  
4
5
6
7
Signal Ground  
Receive Data (in to unit)  
Transmit Data (out of unit)  
None  
Pin 1  
8
None  
This port provides an end-to-end RS-232 line that can support up to 250K Baud and  
is transparent to all RS-232 protocols.  
RS-232 Serial Console Port  
The following table lists the pin configuration for the RS-232 3-pin Mini Jack mating  
connector for the console serial port.  
Pin  
Tip  
Ring  
DB9-F Pin#  
Signal Name  
Transmit  
Receive  
Direction  
Out of Unit  
In to Unit  
Return  
2
3
5
Sleeve  
Return  
Sleeve  
Ring  
Tip  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Instructions  
Each IE-iMcV-E1-Mux/4 module requires two adjacent slots in an iMediaChassis or  
MediaChassis. To install the module in a chassis, remove the blank faceplates  
covering the slots where the module is to be installed. Then slide the module into  
the chassis card guides until the module is seated securely in the slots. Secure the  
module to the chassis by tightening the captive screw.  
All IE-iMcV-E1-Mux/4 units are shipped from the factory configured as Host units.  
The IE-iMcV-E1-Mux/4 modules must be installed in pairs. For two IE-iMcV-E1-  
Mux/4 units to properly operate together one unit needs to be configured as a  
Remote. Configuration as a Host or Remote is controlled via a DIP switch setting (S1-  
1).  
Small Form-Factor Pluggable Ports (SFP  
)
The fiber link on the IE-iMcV-E1-Mux/4 module is supported through one or two SFP  
s
(depending on the model) running at 155Mbps. Many SFPs, including those from  
IMC Networks, feature enhanced diagnostics capabilities DDMI (Data and Diagnostic  
Management Information). DDMI statistics provide real-time access to transceiver  
operating parameters such as voltage, temperature, laser bias current, and both  
transmitted and received optical power. DDMI information can be accessed in  
iView2.  
AutoCross Feature  
The 10/100BaseT Ethernet port on the IE-iMcV-E1-Mux/4 includes an AutoCross  
feature that automatically selects between a crossover workstation and a straight-  
through connection depending on the connected device.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Options  
The following sections describe the configurable features.  
Use the "default" command to restore the unit's default settings. This restores the  
card's default configuration and resets the default username and password.  
User: admin / Password: admin  
Ethernet Line Setup  
If the Ethernet port is not used, it can be set to disabled via a console session or via  
iView², to effectively block all traffic on this port.  
Packet Size  
The Ethernet transport can accommodate packets up to 1916 bytes.  
Auto Negotiation  
The IE-iMcV-E1-Mux/4 ships from the factory with Auto Negotiation enabled on the  
Ethernet port. In this mode, the port negotiates for speed, duplex and flow control.  
Forcing the Speed, Duplex Mode, and Flow Control  
The Ethernet port on the IE-iMcV-E1-Mux/4 can be selectively advertised or manually  
forced for 10 Mbps or 100 Mbps operation at Half- or Full-Duplex (i.e., 10 Mbps  
Full-Duplex, 10 Mbps Half-Duplex, 100 Mbps Full-Duplex, etc.). Flow control can  
also be enabled on the Ethernet port when the connecting equipment supports this.  
These features can be enabled through iView².  
FX LinkLoss and LFPT  
During normal operation, link integrity pulses are transmitted by all point-to-point  
Ethernet devices. When an IE-iMcV-E1-Mux/4 receives valid link pulses, it knows  
that the device to which it is connected is up, and that the cable coming from that  
device is intact. The appropriate “LNK” (link) LED is lit to indicate this. However,  
these signals are not normally transmitted across a normal store and forward Ethernet  
bridge function. A failed Ethernet line on one end of the fiber link is not forwarded  
to the Ethernet port at the other end of the optical transport. A failed optical line is  
also not normally forwarded to the Ethernet port. The FX LinkLoss and LFPT  
functions are used to enable these features.  
For troubleshooting information utilizing the FX LinkLoss and LFPT features of the IE-  
iMcV-E1-Mux/4 modules, refer to Troubleshooting at the end of this manual.  
Both the LinkLoss and LFPT features are set to "Disabled" by default.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FX LinkLoss (FXLL)  
FX LinkLoss is a link integrity monitoring feature that forwards fiber link faults to the  
RJ-45 DATA port to indicate that a fiber link fault has occurred. FX LinkLoss can be  
enabled in iView².  
Link Fault Pass-Through (LFPT  
)
Link Fault Pass-Through (LFPT) is a troubleshooting feature that passes a link fault from  
the Ethernet port on one module through to the Ethernet port on the other module.  
LFPT can be enabled via iView² or through the console port.  
The link fault is passed through the media conversion and is observed at each end. It  
acts just as it would if the end devices were directly connected without a fiber link.  
E1 Ports Setup  
Alarm Level  
E1 lines are defined as LOST when no signal is received as defined by ITU G.775  
specifications LOS, and are considered in error with a BER of 10^-6. If either of  
these conditions lasts for more than 2.5 seconds, an ALARM state is declared. This  
error condition must be absent for 10 seconds for the alarm state to clear.  
The starting and ending event of all alarm conditions will generate an SNMP TRAP  
when the unit is installed in a managed chassis and set to the IS state. During initial  
installation or normal maintenance, the end-user can place the unit in the OOS (Out-  
Of-Service) state to inhibit unwanted SNMP TRAP alarms.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loopback  
Each E1 port can be tested in loopback mode by enabling either a Host loopback or  
Remote loopback test path. This capability allows the end-user to help troubleshoot  
and isolate system problems such as improper/broken line terminations, cables or  
malfunctioning equipment.  
With Host loopback, the E1 copper port, connected to the Host unit, is looped back  
to that port within the local unit. E1 data coming from the remote unit to that port  
over the optical link is also looped back to the remote unit at the same point within  
the local unit.  
With remote loopback, an E1 line connected to the Host unit is transported onto the  
optical link and looped back within the remote unit back onto the optical link  
without passing onto the copper E1 line of the remote unit. The remote’s incoming  
E1 copper line is also looped-back to the copper line within the remote unit.  
The default value for loopback is "none."  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Console Screens  
Configuration Using the Console Port  
The following section describes configuration using the console screens. The Remote  
module is only configured through the Host.  
Login Screen  
After running through an initial self test, the log-in screen is displayed (the diagnostic  
information displayed below is for illustration purposes only and may differ from the  
actual screen display):  
The username is case sensitive with a maximum length of 16 characters. After a  
username is entered, the system prompts the end-user for a password.  
Password is case sensitive with a maximum length of 16 characters. After the system  
validates the username and password, the Main Menu is displayed.  
Main Menu  
From the main menu, the end-user can view essential unit configuration data—  
including active alarms in order of importance—and a clock indicating when the  
displayed information was last refreshed.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menu Options  
1
2
3
4
5
6
7
= Refer to the Unit Configuration Screen  
= Refer to the Port Alarm Status screen  
= Refer to the SFP Line Status screen; SFP DDMI alarms are also displayed  
= Refer to the Ethernet Port Configuration screen  
= Refer to the Ethernet Port Status screen  
= Refer to the E1 Port Configuration screen  
= Refer to the E1 Port Status screen  
NOTE  
On all configuration screens, the title is the same as the "option" selected from the  
previous screen.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Unit Configuration Screen  
The unit configuration screen displays the names of the Host and Remote units as  
well as the service state, whether fiber protection is enabled and the SFP BER alarm  
level. In addition, the unit time can be set from this screen and the username and  
password can be set/reset.  
The screen displays the current status for items 1 through 8. For security reasons, the  
current username and password are not displayed.  
For items 1 through 8, enter the number of the menu item to be changed, and then  
enter the new value when prompted. The unit and port names can be assigned by  
the end-user and are used in SNMP associated TRAP alarm messages.  
Port Alarm Status Screen  
The Port Alarm Status screen displays the status of the Host and Remote alarms on  
each of the unit's ports. This screen can be refreshed as needed to display current  
data.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SFP Line Status Screen  
The SFP Line Status screen displays the status of the Host and Remote SFP links.  
The detailed SFP information may be viewed by entering "1" for SFP A or "2" for SFP B.  
Displayed data includes the manufacturer name, code, part number and revision  
number. These values may not be modified.  
For SFP modules that support DDMI values for temperature, voltage, diode current  
and optical receive/transmit, levels can be obtained through SNMP Management  
Module.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ethernet Port Configuration Screen  
The screen displays the current values for items 1 through 9 for both the Host and  
Remote site.  
Enter the number of the menu item to change its configuration, and then enter the  
new value(s) when prompted.  
Ethernet Port Status Screen  
This screen displays the current Ethernet port status for both the Host and Remote  
site.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E1 Port Configuration Screen  
Use this screen to access the loopback and name details for each of the four E1 ports.  
Enter the number of the menu item to edit, and enter the new value(s) when  
prompted.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E1 Port Status Screen  
Use this screen to display the current status for each of the four E1 ports for the Host  
and Remote units.  
Enter the number of the menu item to edit, and enter the new value(s) when  
prompted.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
All IE-iMcV-E1-Mux/4 units are shipped configured as Host units via DIP  
Switch #1 = OFF. The Remote unit should be set to DIP Switch #1 = ON.  
Be sure to confirm that the IE-iMcV-E1-Mux/4 card is set correctly when  
used.  
The fiber transport is independent of all other ports and should be  
established first. If this is not possible, a physical fiber loopback can be used  
for fiber port verification. A fiber loopback will cause all connected ports to  
loop back their respected data.  
If the fiber is not connected, all E1 ports will send the all-ones, AIS signal.  
This can be physically looped back to verify E1 port operation.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fiber Optic Port Verification  
As a troubleshooting aid, the fiber optic ports can be verified by placing a physical  
loopback optical line on the ports and verify the LED behavior as shown:  
The ACT LED will arbitrarily be configured to either the A or B fiber line. The RAI LED  
is RED/GREEN indicating that there is something wrong at the far end of the fiber line  
(in this case, the remote unit is missing). The ALARM LED is RED because the E1 port  
is not connected. The STAT LED is RED when there is no fiber link but turns GREEN  
when the fiber link is valid.  
NOTE  
The E1 ports are all sending AIS. However, with the fiber looped, it is because of  
the LOS on the E1 port. Without the fiber looped, it is because of the LOS of the  
fiber port.  
WARNING  
An optical loopback will also loop back the Ethernet port. If the network cannot  
tolerate this, remove the Ethernet port connection before connecting the fiber  
loopback.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E1 Port Verification  
By placing a physical loopback connection on the E1 port, a valid signal can be  
detected by each individual E1 port to verify its operation. Without the fiber looped,  
the ALARM LED for the looped E1 port will show RED/GREEN indicating there is a  
problem at the far end of the fiber transport (In this case the far end unit is missing)  
and the STAT LED is RED because the fiber is in LOS. With the fiber looped, the E1  
port will only show a normal GREEN STAT LED.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Normal Operation  
Under normal operation the following LED display is given:  
GREEN LNK  
E1  
E1  
10/100BaseT  
RS-232  
10/100BaseT  
RS-232  
E1  
E1  
E1  
E1  
E1  
E1  
GREEN STAT  
GREEN  
ACT, LNK, MSA  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fiber Optic Cleaning Guidelines  
Fiber Optic transmitters and receivers are extremely susceptible to contamination by  
particles of dirt or dust, which can obstruct the optic path and cause performance  
degradation. Good system performance requires clean optics and connector ferrules.  
1. Use fiber patch cords (or connectors, as appropriate) only from a reputable  
supplier; low-quality components can cause many hard-to-diagnose problems in  
an installation.  
2. Dust caps are installed at IMC Networks to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting  
the fiber cable to the device. Should it be necessary to disconnect the fiber  
device, reinstall the protective dust caps.  
3. Store spare caps in a dust-free environment such as a sealed plastic bag or box  
so that when reinstalled they do not introduce any contamination to the optics.  
4. If it is suspected that the optics have been contaminated, alternate between  
blasting with clean, dry, compressed air and flushing with methanol to remove  
particles of dirt.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrostatic Discharge Precautions  
Electrostatic discharge (ESD) can cause damage to any product, add-in modules or  
stand alone units, containing electronic components. Always observe the following  
precautions when installing or handling these kinds of products  
1. Do not remove unit from its protective packaging until ready to install.  
2. Wear an ESD wrist grounding strap before handling any module or component.  
If the wrist strap is not available, maintain grounded contact with the system unit  
throughout any procedure requiring ESD protection.  
3. Hold the units by the edges; do not touch the electronic components or gold  
connectors.  
4. After removal, always place the boards on a grounded, static-free surface, ESD  
pad or in a proper ESD bag. Do not slide the modules or stand alone units over  
any surface.  
WARNING! Integrated circuits and fiber optic components are  
extremely susceptible to electrostatic discharge damage. Do not  
handle these components directly unless you are a qualified service  
technician and use tools and techniques that conform to accepted  
industry practices.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Power Consumption (Typical)  
0.96A @ +5 VDC  
Operating Temperature  
+32°C to +158°F (0°C to +70°C)  
Storage Temperature  
-40°F to +158°F (-40°C to +70°C)  
Humidity  
5 to 95% (non-condensing); 0 to 10,000 ft. altitude  
Dimensions  
Dual Slot iMcV module  
Standards/Compliance  
IEEE 802.3x Flow Control  
IEEE 802.3i 10Base-T twisted pair  
IEEE 802.3u 100Base-TX twisted pair  
IEEE 802.3u 100Base-FX or SX fiber  
ITU G.775  
GR-820-CORE  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMC Networks Technical Support  
Tel: (949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);  
+32-16-550880 (Europe)  
Fax: (949) 465-3020  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Definition of Terms/Acronyms  
The following are terms and phrases used within this manual (shown in italics), or  
which are found in documents associated with this equipment.  
1+1  
The Term “1+1” refers to line protection where identical  
information is transmitted on two redundant lines. The Receiver  
chooses the “best” line to use based on the BER of the line.  
AIS  
Alarm Indication Signal: Used in E1 signaling, the AIS is a  
predetermined bit stream (all ones) that is transmitted (forwarded)  
upon the loss of an incoming E1 signal or when the E1 signal is  
disrupted.  
AN  
BER  
CLI  
CV  
Auto Negotiation: A signaling protocol used by an Ethernet PHY to  
determine the characteristics (speed, duplex mode) of its “link  
partner” and configure itself automatically  
Bit Error Rate: The percentage of bits with errors divided by the  
total number of bits that have been transmitted, received or  
processed over a one second time period.  
Command Line Interface: An interface screen, often DOS-based,  
used for system management and diagnostics requiring the user to  
type commands rather than use a GUI  
.
Code Violation: An anomaly of a decoded physical-layer signal  
stream resulting in coding (signaling) error(s). Noise bursts or  
intermittent connections on a link are the usual causes of code  
violations; an HDB3 coding error.  
DDMI  
FFL  
Digital Diagnostic Monitor Interface: A defined serial interface and  
data format typically used to access SFP internal information  
Fiber Fault Loopback: When the fiber line fails, the Ethernet port  
that is being forwarded over the fiber line is forced out of LINK.  
Similar to the Fiber Alert function.  
GUI  
Graphical User Interface: Software that provides a visual interface  
to enable an end-user to manage and monitor network devices.  
HDB3  
High Density Bipolar 3 Coding: A physical-layer signal encoding  
scheme defined for E1 transmission which ensures sufficient  
signaling transitions for robust clock/data recovery.  
IS  
In-Service stat is the normal state of an active port with normal  
error reporting.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED  
Light Emitting Diode: A small stack of lights to indicate link,  
duplex or other options.  
LFPT  
Link Fault Pass-Through: LFPT can be enabled via iView² or  
through the console port.  
LOF  
Loss Of Frame: An error condition where the receiver/decoder  
misses detection of the framing signal.  
LOS  
Loss Of Signal: An error condition where the receiving line  
interface unit does not detect a signal.  
MDI/MDIX  
Media-Dependent Interface/ Media-Dependent Interface  
Crossover. The ability of an Ethernet port to automatically detect  
and configure its cabling connections to accommodate crossover  
or non-crossover wiring, depending on its link partner and cabling.  
MIB  
Management Information Base: A database of objects that can be  
monitored by a network management system. Both SNMP and  
RMON use standardized MIB formats that allow any SNMP and  
RMON tools to monitor any device defined by a MIB.  
MSA  
OOS  
Multi-Source Agreement (SFP): The standard an SFP must meet to  
be compatible in network devices.  
Out-Of-Service, OOS is used by the CRAFT personnel to turn OFF  
the alarm reporting so they can service the line without causing  
alarm TRAPS to be sent to the NOC Center. The LEDs display a  
line status but do not report any line related alarms back to the  
NOC. A card removal or insertion is still reported, but a PORT  
up/down or changes to its configuration are not.  
POP  
RAI  
Point(s) Of Presence: The demarcation point where carrier owned  
equipment is located at the customer site.  
Remote Alarm Indication: Status information received from the  
line indicating there is an alarm condition at the far end of the  
transport.  
SFP  
Small Form-Factor Pluggable: An industry standard optical  
pluggable module.  
SNMP  
Simple Network Management Protocol: A set of protocols for  
managing complex networks over a standards-based IP network.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Certifications  
CE: The products described herein comply with the Council Directive on  
Electromagnetic Compatibility (2004/108/EC).  
European Directive 2002/96/EC (WEEE) requires that any equipment that bears this  
symbol on product or packaging must not be disposed of with unsorted municipal  
waste. This symbol indicates that the equipment should be disposed of separately  
from regular household waste. It is the consumer’s responsibility to dispose of this  
and all equipment so marked through designated collection facilities appointed by  
government or local authorities. Following these steps through proper disposal and  
recycling will help prevent potential negative consequences to the environment and  
human health. For more detailed information about proper disposal, please contact  
local authorities, waste disposal services, or the point of purchase for this equipment.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19772 Pauling • Foothill Ranch, CA 92610-2611 USA  
TEL: (949) 465-3000 • FAX: (949) 465-3020  
© 2011 IMC Networks. All rights reserved.  
The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any  
errors that may appear in this document. IE-iMcV-E1-Mux/4 is a trademark of IMC Networks. Other brands or product  
names may be trademarks and are the property of their respective companies.  
Document Number 57-80400-02 A0  
November 2011  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Greenheck Fan Fan 240XP CUb User Manual
Grindmaster Beverage Dispenser PIC 6 User Manual
Haier Refrigerator hc125fvs User Manual
Harbor Freight Tools Grinder 45707 User Manual
Hearth and Home Technologies Indoor Fireplace WTBC36BB User Manual
Hotpoint Range RGB746DEP User Manual
Hotpoint Refrigerator HTS18ICP User Manual
HP Hewlett Packard Printer 2230 series User Manual
Humax Satellite TV System CI 5100X User Manual
Impex Home Gym MD 8861 User Manual