IBM Switch B24X User Manual

ꢀꢁꢂ  
®
IBM Ethernet Switch B24X  
IBM System x at-a-glance guide  
The IBM Ethernet Switch B24X is a compact, high-performance, high-availability, and high-density 10  
GbE solution that meets mission-critical data center and High Performance Computer (HPC)  
requirements. It can support 1 GbE servers until they are upgraded to 10 GbE-capable Network Interface  
Cards (NICs), simplifying migration to 10 GbE server farms.  
In addition, the B24X is a fully featured switch with IPv4 Layer 3 capabilities that can provide cost-efficient  
10 GbE network aggregation for 1 GbE access switches. The switch runs a feature-rich and mature  
IronWare Operating System with an industry-standard command-line interface (CLI), minimizing  
re-training and operational costs. Supporting a full range of Request for Comments (RFC) and Institute of  
Electrical and Electronics Engineers (IEEE) standards for interoperability, along with compatibility for  
vendor-specific protocols such as Cisco Discovery Protocol (CDP) and Per-VLAN Rapid Spanning Tree  
Plus (PVRST+), the B24X integrates seamlessly into existing network infrastructures.  
Figure 1. IBM Ethernet Switch B24X (front view)  
Figure 2. IBM Ethernet Switch B24X (back view)  
Did you know  
The IBM Ethernet Switch B24X is the most power-efficient 10 Gbps switch in its class at 176 watts per  
twenty-four 10 GbE ports. This saves customers up to 56% in power and cooling costs over competing  
switches. In addition, the high-performance, cut-through, full-mesh non-oversubscribed (1:1) architecture  
of the B24X offers up to twice the performance with lower latencies and uses up to 2 - 3 times less rack  
space.  
The no-compromise B24X also features data center class network resiliency and hardware availability  
features to support non-stop networking, making the switch ideal as an all-purpose Top of Rack switch  
IBM Ethernet Switch B24X  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Power cords are not included and must be specified at the time of order. The B24X has a C14 inlet to  
receive a C13 power plug. Table 2 lists the available power cable options.  
Table 2. Power cord options  
Part  
number  
Description  
Line cord – 2.8 m, 10A/230V, C13 to CEE7-VII (Europe)  
Line cord – 2.8 m, 10A/250V, C13 to DK2-5a (Denmark)  
Line cord – 2.8 m, 10A/250V, C13 to SEV 1011-S24507 (Swiss)  
Line cord – 2.8 m, 10A/250V, C13 to SI 32 (Israel)  
39Y7917  
39Y7918  
39Y7919  
39Y7920  
39Y7922  
39Y7923  
39Y7924  
39Y7925  
39Y7927  
39Y7928  
39Y7929  
39Y7930  
39Y7931  
39Y7932  
39Y7937  
Line cord – 2.8 m, 10A/250V, C13 to SABS 164 (S. Africa)  
Line cord – 2.8 m, 10A/250V, C13 to BS 1363/A (UK)  
Line cord – 2.8 m, 10A/250V, C13 to AS/NZ 3112 (Australia/NZ)  
Line cord – 2.8 m, 220-240V, C13 to KETI (S. Korea)  
Line cord – 2.8 m, 10A/250V, C13 to (2P+Gnd) (India)  
Line cord – 2.8 m, 220-240V, C13 to GB 2099.1 (China)  
Line cord – 2.8m, 125V, C13 to NBR 6147 (Brazil)  
Line cord – 2.8 m, 10A/250V, C13 to IRAM 2073 (Australia)  
Line cord – 4.3 m, 10A/125V, C13 to NEMA 5-15P (US)  
Line cord – 4.3 m, 10A/100-250V, C13 to IEC 320-C14  
Line cord – 1.5 m, 10A/100-250V, C13 to IEC 320-C14  
Each SFP+ optical transceiver, such as the 10GBASE-SR SFP+, requires fiber optic cabling with duplex  
LC connectors to connect to another optical transceiver. See the “Network cabling requirements” section  
for additional details.  
Each 10/100/1000 MbE RJ-45 port or the 1 GbE copper SFP transceiver (1000BASE-T) requires copper  
CAT 5e or higher cabling for connectivity. Table 3 lists the available copper cable options.  
Table 3. Ethernet copper cable (RJ-45) options  
Description  
IBM part number  
40K5679  
0.6 m Ethernet cable (blue)  
1.5 m Ethernet cable (blue)  
3 m Ethernet cable (blue)  
10 m Ethernet cable (blue)  
25 m Ethernet cable (blue)  
40K8785  
40K5581  
40K8927  
40K8930  
IBM Ethernet Switch B24X  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Additional options are available through IBM System Networking HVEC channels. Table 4 lists the  
orderable part numbers for these additional options.  
Table 4. IBM part numbers and feature codes for ordering (System Networking HVEC)  
Description  
IBM part  
number  
IBM feature  
code  
10 GbE Direct Attach SFP+, 1 m, Active TwinAx copper cable  
10 GbE Direct Attach SFP+, 3 m, Active TwinAx copper cable  
10 GbE Direct Attach SFP+, 5 m, Active TwinAx copper cable  
45W2398  
45W2408  
45W3039  
2711  
2731  
2751  
1 GbE 100 m SFP, 1000BASE-T (RJ-45, connects to CAT5 or  
higher cabling)  
45W2813  
2202  
1 GbE 550 m SFP, 1000BASE-SX (duplex LC, MMF, 850 nm, OM)  
1 GbE 10 km SFP, 1000BASE-LX (duplex LC, SMF, 1310 nm, OM)  
45W2815  
45W2816  
2211  
2212  
2213  
2131  
1 GbE 70 km SFP, 1000BASE-LHA (duplex LC, SMF, 1550 nm, OM) 45W2817  
10 GbE 10 km, SFP+, 10GBASE-LR (duplex LC, SMF, 1310 nm, 45W4264  
OM)  
Note: OM = Optical Monitoring supported. SMF = single-mode fiber. MMF = multi-mode fiber. MMF  
distance supported depends on cabling type. Use OM3 50 ìm (2000 MHz*km) MMF to support the farthest  
distances.  
The B24X has twenty-four dual-speed 10/1 GbE SFP+ ports enabling customers to seamlessly transition  
their 1 GbE devices to 10 GbE speeds by upgrading the transceiver. Qualified SFP+ or SFP transceivers  
are required for each SFP+ port and are not included. Up to twenty-four 10 GbE SFP+ or 1 GbE SFP  
transceivers are supported on each IBM Ethernet Switch B24X.  
10 GbE SFP+ optical –SR (10GBASE-SR) transceivers support distances up to 300 m, which is ideal for  
connectivity within a data center. 10 GbE SFP+ optical –LR (10GBASE-LR) transceivers support extended  
distances up to 10 km.  
Figure 3. SFP+/SFP optical transceiver - Receives duplex LC connectors  
IBM Ethernet Switch B24X  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
For cost-effective server connectivity within a rack, 10 GbE copper direct attach SFP+ active TwinAx  
cables are available. These cables have two 10 GbE SFP+ transceivers attached on either end of the  
cable and have been tested for compatibility with the Brocade 10Gb CNA, QLogic 10Gb CNA, and  
Emulex 10Gb Virtual Fabric Adapter for IBM System x. Compatibility with other 10 GbE server adapters  
and network devices is up to the user to determine.  
Figure 4. 10 GbE Direct Attach SFP+ TwinAx cable  
Features and benefits  
The features and benefits are:  
z
Comprehensive standards support: Supporting a wide range of open IEEE and RFC standards, the  
B24X is fully interoperable with existing network environments. In addition, the B24X supports  
vendor-specific protocols such as Cisco Discovery Protocol (CDP), native support for Per-VLAN  
Rapid Spanning Tree Plus (PVRST+), and static trunks to EtherChannel for further supportability.  
z
z
Built for the data center: The B24X features front-to-back airflow, allowing installation into racks with a  
hot-cold aisle design without the need for complicated air baffles. All ports are found on the front side  
of the switch for easy serviceability.  
Flexible deployment: Dynamic Layer 3 routing allows the B24X to support multiple deployment  
options, including a Top of Rack access switch supporting inter-VLAN routing within a rack or a  
cost-effective aggregation switch.  
z
z
High availability: Hot-swappable and redundant power supplies and fan trays reduce downtime and  
allow you to meet your service level agreements by increasing switch availability.  
Best-in-class power efficiency: At only 176 W per twenty-four 10 GbE ports, the low power  
consumption reduces operational costs tied to power and cooling and allows data centers running out  
of power to deploy more assets.  
z
High performance: Supporting full-line rate traffic on all ports with no over-subscription and 488 Gbps  
of internal forwarding performance, the B24X also uses an advanced cut-through forwarding  
architecture featuring low latencies to support time-sensitive applications such as real-time video and  
market trading/exchange applications.  
z
z
Industry-standard CLI: Minimize re-training and personnel costs while increasing operational  
efficiencies by utilizing a management interface with which the network team is already familiar.  
Mature operating system: The feature-rich and time-tested IronWare Operating System running on  
the B24X and all IBM b-type system networking devices provides a consistent experience across the  
network.  
z
Upgrade without rip-and-replace: With dual-speed 10/1 GbE SFP+ ports plus four additional 1 GbE  
RJ-45 ports, the B24X supports a mix of 10 GbE and 1 GbE servers on the same switch without  
needing to force upgrades of existing systems.  
IBM Ethernet Switch B24X  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
z
Granular network visibility: Hardware-based sFlow v5 provides packet sampling for analysis, trending,  
and application of automated policies based on thresholds using industry applications such as  
Brocade Ironview Network Manager.  
Cost competitive: The B24X includes all software capabilities and a 3-year warranty of the base  
product, simplifying ordering while being priced extremely competitively compared with other vendors.  
Specifications  
The IBM Ethernet Switch B24X supports the following specifications when running IronWare R04.2.x and  
higher. Be aware that Layer 3 capabilities are supported on IronWare R04.2.x and higher, and further  
details can be found by navigating the IBM Support website:  
z
Form-factor  
z
z
1 RU; 43.5 cm (17.1 in.) width x 4.28 cm (1.7 in.) height x 39.4 cm (15.5 in.) depth  
Rack-mount into 19” EIA-310D compliant rack, Telco rack, or table-top  
z
z
z
Ports (data)  
z
z
Twenty-four dual-speed 10/1 GbE SFP+ ports  
Four 10/100/1000 MbE RJ-45 ports  
Ports (management, out-of-band)  
z
z
One10/100/1000 MbE RJ-45 port  
One DB9 male serial console port  
Power supplies, fans, and airflow  
z
Two 300 W AC hot-swappable power supplies supported for 1+1 redundancy (base switch  
comes with one)  
z
z
One hot-swappable fan tray with three 2+1 redundant fans  
Front-to-back airflow supporting data center hot-cold aisle deployments  
z
Performance  
z
z
z
488 Gbps line speed full-duplex throughput  
363 Mpps forwarding capacity  
1.5 micro-second latency  
z
z
z
Jumbo frames  
z
Supported: up to 9216-byte Ethernet frame sizes  
Media (transceivers)  
z
10 GbE SFP+ -SR transceivers and direct attach copper TwinAx cables available  
VLANs  
z
z
z
z
z
z
z
Up to 4096 maximum VLANs  
802.1Q tagging  
802.1Q-in-Q tagging  
Dual-mode VLANs (tagged and untagged traffic across same port)  
Port-based VLANs  
VLAN groups  
Private VLANs  
IBM Ethernet Switch B24X  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
z
Link aggregation  
z
z
z
Up to eight links per group, 28 link groups per switch  
Static trunks compatible with Cisco EtherChannel  
802.3ad Link Aggregation Control Protocol (LACP) for dynamic trunk groups  
Quality of service (QoS) and rate shaping  
z
Eight queues per port with strict priority (SP), weighted round robin (WRR), and combined  
SP/WRR schedulers  
z
z
z
z
z
802.1p Class of Service (CoS)  
IP DSCP/DiffServ (Type of Service) to priority mapping  
ACL, port, and static MAC address to priority mapping  
Layer 2 CoS and Layer 3 DSCP re-marking  
Outbound rate shaping  
z
Layer 2  
z
z
Up to 32,000 MAC addresses.  
Per-VLAN Rapid Spanning Tree Protocol Plus (PVST/PVST+/PVRST+) compatibility in  
default configuration supports smooth implementation into Cisco Layer 2 environments.  
z
z
z
802.1d Spanning tree Protocol (STP).  
802.1w Rapid Spanning Tree Protocol (RSTP).  
802.1s Multiple Spanning Tree Protocol (MSTP) enables multiple STP instances and  
forwarding paths for more efficient traffic distribution.  
z
z
Virtual Switch Redundancy Protocol (VSRP) alternative to STP and includes sub-second  
convergence and Layer 2 redundancy based on the VRRPE protocol.  
Metro Ring Protocol (MRP) v1/v2 enables fast, sub-second convergence in ring topologies.  
IGMPv1/v2/v3 Snooping and PIM-SM Snooping reduce multicast flooding in a Layer 2  
network.  
z
z
z
Root Guard prevents rogue devices from hijacking STP root.  
BPDU Guard prevents rogue devices from participating in STP.  
DHCP Assist helps DHCP servers respond correctly to devices in a different subnet than the  
DHCP server.  
z
Layer 3  
z
z
z
z
z
z
z
Up to 12,000 IPv4 routes  
Routing Information Protocol (RIP) v1/v2  
Open Shortest Path First (OSPF) v2  
Internet Group Management Protocol (IGMP) v1/v2/v3  
Protocol Independent Multicast Dense Mode (PIM-DM) v1/v2 and Sparse Mode (PIM-SM) v2  
Equal Cost Multi Path (ECMP) for load balancing across up to eight paths  
Virtual Router Redundancy Protocol (VRRP) and VRRP-E (Enhanced)  
IBM Ethernet Switch B24X  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
z
Security  
z
802.1x authentication, accounting, port security, and dynamic assignment for ACLs, MAC  
filtering, and VLANs  
z
z
z
z
Up to 1,534 inbound, rule-based (hardware-based) access control list (ACL) entries  
Standard ACLs based on source IP address  
Extended ACLs based on source and destination IP addresses or IP protocol information  
Authorization, Authentication, and Accounting (AAA) support on RADIUS, TACACS, and  
TACACS+  
z
Multi-device authentication, which validates and applies security policies based on MAC  
address information from a RADIUS server  
z
z
AES encryption for SSHv2  
Denial of Service protection against Smurf (ICMP) and TCP SYN attacks in hardware  
z
Management  
z
z
z
Industry-standard CLI via Telnet and SSHv2  
Fault management integration with IBM Systems Director v6.2  
Network-wide management of all IBM b-type system networking switches using Brocade  
Ironview Network Manager (INM)  
z
z
Simple Network Management Protocol (SNMP) v1/v2/v3  
sFlow v5 for hardware-based packet sampling  
z
Ties into industry tools such as Brocade INM and InMon products for trend analysis  
and automated policy application  
z
z
Remote Monitoring (RMON) protocol  
Link Layer Discovery Protocol (LLDP), Cisco Discovery Protocol (CDP), and Foundry  
Discovery Protocol (FDP)  
z
z
Simple Network Time Protocol (SNTP)  
Firmware image update via TFTP and SCP  
z
Monitoring  
z
z
z
Syslog support of up to six Syslog servers for centralized log collection and analysis.  
Port mirroring of inbound and outbound traffic.  
Digital optical monitoring monitors power levels and temperatures of optical transceivers and  
sends an alert if operating out of specification.  
z
z
Temperature monitoring sends alerts if the temperature exceeds a certain threshold and  
shuts down the device after an extended period of time.  
Port flap dampening increases network resiliency by limiting the number of port state  
transitions on an interface.  
z
z
Link Fault Signaling (LFS) detects and reports fault conditions on 10 GbE ports.  
Uni-Directional Link Detection (UDLD) monitors the link between two devices and brings the  
port down if the link goes down on either end.  
IBM Ethernet Switch B24X  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connectivity options  
The B24X supports a wide variety of industry IEEE and RFC standards and should interoperate with any  
network device that supports industry standard Ethernet connectivity. This includes servers, other  
Ethernet switches, iSCSI Storage Area Network (SAN) arrays, Network-Attached Storage (NAS) arrays,  
and other network devices. Figure 5 shows the IBM Ethernet Switch B24X (front view with port labeling).  
Figure 5. IBM Ethernet Switch B24X (front view with port labeling)  
IBM Ethernet Switch B24X  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 5 lists the methods that the B24X can use to connect to another device.  
Table 5. Connectivity options  
On the B24X  
On the device to be connected  
SFP+ port using 10 GbE SFP+ optical The optic on the device being connected can be  
transceiver: 69Y0389: 10GBASE-SR  
another form-factor (that is, XFP transceiver, X2  
module, or integrated into NIC), but must have a  
matching optical transmission type.  
This optical transceiver receives a  
duplex LC connector.  
For example, a 10GBASE-SR XFP optical  
transceiver on the device being connected must  
match a 10GBASE-SR SFP+ optical transceiver on  
the B24X within the proper wavelength and power  
specifications.  
Multi-mode or single-mode fiber as specified  
required for connectivity. See the "Network cabling  
requirements" section.  
SFP+ port using 10 GbE Direct Attach It is up to the user to decide whether the interface  
SFP+ Active TwinAx cable:  
on the device being connected supports the IBM  
DAC used with the B24X.  
z 45W2398 or 45W2401: 1 meter  
z 45W2408 or 45W2409: 3 meter  
z 45W3039 or 45W3042: 5 meter  
Below is a list of IBM server adapters that have  
been tested for compatibility with the part numbers  
in the left-hand column. If a product is not listed,  
that does not necessarily mean that it is  
Direct Attach Cables (DACs) are  
copper cables with two SFP+  
transceivers attached to either end of  
the cable.  
incompatible--it simply has not been tested.  
IBM server adapters:  
z 42C1820: Brocade 10Gb Converged Network  
Adapter for IBM System x  
z 49Y4250: Emulex 10Gb Virtual Fabric Adapter  
for IBM System x  
z 42C1800: QLogic 10 Gb CNA for IBM System x  
10/100/1000 MbE RJ-45 port:  
Auto-sensing, auto-negotiating,  
auto-MDI/MDIX.  
Connect to any RJ-45 port or TX adapter  
supporting 10, 100, or 1000 Mbps Ethernet over  
CAT5 or higher cabling up to 100 meters.  
Connectivity to IBM System servers  
The B24X can be deployed as a Top of Rack access switch to provide connectivity to servers within a  
rack. This includes servers from IBM System x, System p, and System i.  
IBM System x servers typically come with on-board 1 Gbps Ethernet RJ-45 ports. Additional 1 GbE NICs  
can be installed to increase connectivity. These NICs might have RJ-45 ports, SFP ports requiring a  
transceiver, or integrated optical transceivers. Follow the guidelines in Table 5 for connectivity.  
IBM Ethernet Switch B24X  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10 Gbps Ethernet connectivity is not standard in most System x servers, and a 10 GbE NIC or 10 GbE  
CNA must be installed. Only the IBM System x3850/3950 X5 series (except for the ARx model) come  
standard with a customized Emulex Virtual Fabric Adapter. Table 6 lists the 10 GbE adapters that are  
available for IBM System x servers.  
Table 6. 10 Gbps adapters for IBM System x servers  
System x  
rack and  
tower  
server  
adapter  
models  
Brocade  
10Gb  
CNA  
(42C1820  
)
N0.  
22  
6
N
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
QLogic  
10Gb  
CNA  
(42C1800  
)
Y
Y
Emulex  
Virtual  
Fabric  
Adapter  
(49Y4250  
)
NetXtrem  
e II 10  
N
N
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
GigE  
Express  
Fiber SR  
Adapter  
(42C1790  
)
The Brocade 10Gb CNA [42C1820], QLogic 10Gb CNA [42C1800], and Emulex Virtual Fabric Adapter  
[49Y4250] each have two SFP+ ports and can be connected to the B24X using:  
z
The adapter’s supported 10GBASE-SR SFP+ transceiver connected to the B24X 10GBASE-SR  
SFP+ transceiver [69Y0389] over multi-mode fiber cable.  
z
The Direct Attach SFP+ Active TwinAx copper cables listed in Table 4.  
The NetXtreme II 10 GigE Express Fiber SR Adapter (42C1790) has a single integrated 10GBASE-SR  
optic. This port can be connected to the B24X 10GBASE-SR SFP+ transceiver [69Y0389] over a  
multi-mode fiber cable.  
Connectivity to IBM BladeCenter  
The B24X can be deployed as an aggregation switch to provide connectivity between down-stream  
IBM Ethernet Switch B24X  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
switches. This includes IBM System Networking switches, BladeCenter Ethernet embedded switches, and  
Ethernet switches from other vendors  
IBM BladeCenter Ethernet Switch Modules are available with 1 Gbps and 10 Gbps Ethernet uplinks.  
Table 7 lists the various IBM BladeCenter Ethernet Switch Modules that can be used to connect to the  
B24X.  
Table 7. IBM BladeCenter Ethernet Switch Modules (ESM)  
BladeCenter Ethernet  
Switch Module models  
Ext. 1  
GbE  
ports  
Ext. 10  
GbE  
ports  
Part #  
BC H  
Y
BC HT  
BC E  
N
BC T  
N
BC S  
N
BNT Virtual Fabric 10Gb  
ESM  
46C71  
91  
10 dual-speed  
SFP+  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Cisco Nexus 4001I ESM  
46M6  
071  
6 dual-speed  
SFP+  
Y
N
N
N
1 X21  
0
Cisco Catalyst 3110X ESM 41Y85  
22  
Y
Y
Y
N
10Gb Ethernet Pass-Thru  
Module  
46M6  
181  
0
14  
SFP+  
Y
N
N
N
BNT 1/10Gb Uplink ESM  
44W4  
404  
6
3 SFP+  
Y
Y
Y
Y
RJ-45  
BNT Layer 2/3 Copper  
ESM  
32R18  
60  
6
0
0
0
0
0
0
0
Y
Y
Y
Y
RJ-45  
BNT Layer 2/3 Fiber ESM  
32R18 6 SFP  
61  
Y
Y
Y
Y
BNT Layer 2-7 Gigabit  
ESM  
32R18  
59  
4
Y
Y
Y
Y
RJ-45  
Cisco Catalyst 3012 ESM  
43W4  
395  
4
Y
Y
Y
Y
RJ-45  
Cisco Catalyst 3110G  
ESM  
41Y85  
23  
4
Y
Y
Y
N
RJ-45  
Server Connectivity  
Module  
39Y93  
24  
6
Y
Y
Y
Y
RJ-45  
Intelligent Copper  
Pass-Thru Module  
44W4  
483  
14  
RJ-45  
Y
Y
Y
Y
Note 1: X2 modules have duplex SC connectors. An SC-to-LC fiber cable is required to connect to a SFP+  
transceiver with duplex LC connectors.  
For Ethernet Switch Modules with SFP+ or X2 ports see the respective IBM Redbooks at-a-glance guide  
to locate transceivers supported. Review Table 5 for guidance on how to connect the Ethernet Switch  
Module to the B24X.  
Popular configurations  
This section illustrates how the IBM Ethernet Switch B24X can be used in various configurations.  
IBM Ethernet Switch B24X  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Top of Rack switch  
An access or edge switch is a switch that connects directly to the end devices requiring network  
connectivity, most commonly servers and storage arrays in the data center. A switch that is 1 or 2 RU in  
height that acts as the access switch for devices within a rack is commonly called a Top of Rack switch.  
The B24X is ideal for deployment as an all-purpose Top of Rack switch in demanding network  
environments due to its high-performance, resilient hardware characteristics and comprehensive network  
features support. The B24X can also be used to support NAS or iSCSI SAN storage in a shared or  
dedicated network environment (Figure 6).  
Figure 6. IBM Ethernet Switch B24X as Top of Rack switch with server and storage connections  
IBM Ethernet Switch B24X  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 8 outlines the components used in Figure 6.  
Table 8. Components used in reference to Figure 6  
Diagram  
reference  
Part number/  
machine type  
Description  
Quantity  
2
0563-012  
IBM Ethernet Switch B24X  
IBM System x server with 10 GbE NIC/CNAs  
z See Table 5 for additional details.  
z Other vendor servers can be used.  
Varies  
16  
NAS array  
Varies  
Varies  
Existing network infrastructure, which can  
include IBM Systems Networking devices and  
other standards-compliant Ethernet/IP switches  
and routers  
Varies  
-
0563-012  
Varies  
IBM Ethernet Switch B24X  
iSCSI SAN array  
2
Varies  
Solution details are:  
z
z
z
z
Forty-one rack units (with two RU servers)  
1:1 subscription ratio within rack  
2.43:1 over-subscription ratio to rest of network  
Connectivity to NAS or iSCSI SAN (or both) for mid-range scalable storage  
In the solution shown in Figure 6 we have two IBM Ethernet Switch B24Xs providing connectivity to all  
devices within a single rack. Within the rack we have a mix of servers with 10 GbE connections to each  
B24X for redundancy. The B24X can also be used to connect to NAS arrays for scale-out file sharing and  
also to a separate iSCSI SAN for dedicated storage access as bandwidth and security needs require.  
IBM Ethernet Switch B24X  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network device connections  
Figure 7 shows an example of the types of options that can be used to connect separate devices to the  
IBM Ethernet Switch B24X  
Figure 7. IBM Ethernet Switch B24X device connections  
IBM Ethernet Switch B24X  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 9 outlines the components used in Figure 7.  
Table 9. Components used in reference to Figure 7  
Diagram  
reference  
Part number/  
machine type  
Description  
Quantity  
2
IBM Ethernet Switch B24X  
0563-012  
IBM x3850/x3960 X5 (except ARx model)  
z Comes with 2-port 10 GbE (SFP+) Emulex  
Virtual Fabric Adapter.  
z Use a single Direct Attach cable (TwinAx)  
to connect to B24X, available in 1, 3, or 5  
meters. (See Table 4.)  
Varies  
-
NAS or iSCSI storage array  
Varies  
Varies  
Cisco Catalyst 3110X Ethernet Switch Module  
z On 3110X, use X2-10GB-SR=  
(10GBASE-SR X2 module).  
z On B24X, use 69Y0389 (10GBASE-SR  
41Y8522  
46C7191  
2
2
SFP+).  
z Connect over multi-mode fiber. (Note: The  
X2 module has a SC connector, whereas  
the SFP+ has a LC connector.)  
BNT Virtual Fabric 10Gb Ethernet Switch  
Module  
z On BNT ESM, use 44W4408  
(10GBASE-SR SFP+).  
z On B24X, use 69Y0389 (10GBASE-SR  
SFP+).  
z Connect over multi-mode fiber.  
IBM System x server  
z On System x server with Brocade 10Gb  
CNA [42C1820], QLogic 10Gb CNA  
[42C1800], or Emulex Virtual Fabric  
Adapter [49Y4250], connect using a single  
Direct Attach cable (TwinAx), available in 1,  
3, or 5 meters. (See Table 4.)  
Varies  
-
z On System x server with NetXtreme II 10  
GigE Express Fiber SR Adapter  
(42C1790), use 69Y0389 (10GBASE-SR  
SFP+) on B24X and connect over  
multi-mode fiber.  
z See Table 6 for server adapter details.  
Other servers  
z If 10GBASE-SR, connect to B24X using  
69Y0389 (10GBASE-SR SFP+) over  
multi-mode fiber.  
Varies  
-
z If 1 GbE, most 1 GbE NICs are RJ-45.  
Connect to one of the B24X’s four RJ-45  
ports over CAT5 cable.  
IBM Ethernet Switch B24X  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interoperating in existing network environments  
The IBM Ethernet Switch B24X interoperates seamlessly in existing network environments utilizing  
standards-based protocols. IBM Ethernet Switch B24X leverages the proven IronWare Operating System  
with an industry-standard CLI so network administrators can utilize their existing skill sets.  
Figure 8 shows an example of the B24X used as an access and aggregation switch.  
Figure 8. IBM Ethernet Switch B24X connecting to the network infrastructure  
IBM Ethernet Switch B24X  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 10 outlines the components used in Figure 8.  
Table 10. The components used in Figure 8  
Diagram  
Reference  
Part number/  
machine type  
Description  
IBM Ethernet Switch B24X  
Quantity  
1
0563-012  
IBM Ethernet Switch B16M  
z On B16M, use FC1711 (4-port 10 GbE XFP  
module) and FC2110 (10GBASE-SR XFP).  
z On B24X, use 69Y0389 (10GBASE-SR SFP+).  
z Connect over multi-mode fiber.  
4003-M16  
1
1
Cisco Catalyst 6509-E  
z On 6509, use 8-port 10 GbE Fiber module with  
X2-10GB-SR (10GBASE-SR X2 module).  
z Connect over multi-mode fiber. (Note: The X2  
module has a SC connector, whereas the SFP+  
has a LC connector.)  
N/A  
IBM Ethernet Switch B48Y (Data Center model)  
z On B48Y, use 81Y1455 (4-port 10 GbE SFP+  
module).  
z Use a single Direct Attach cable (TwinAx) to  
connect to B24X, available in 1, 3, or 5 meters if  
length permits.  
z Otherwise, on B24X use 69Y0389  
(10GBASE-SR SFP+) and connect over  
multi-mode fiber.  
0563-HCF  
1
1
Cisco Catalyst Nexus 4948-10GE  
z On the Catalyst use the 10GBASE-SR X2  
module.  
N/A  
z On B24X, use 69Y0389 (10GBASE-SR SFP+).  
z Connect over multi-mode fiber  
Power supplies and fans  
The IBM Ethernet Switch B24X comes with one 300 W AC power supply and supports a second power  
supply for 1+1 redundancy. The power supplies are hot-swappable, auto-sensing, auto-switching, and  
load sharing, with a universal input (90 VAC to 264 VAC). The power supply has an IEC-C14 inlet that  
connects to a C13 power connector. Power cords are not included with the switch and must be provided  
separately.  
The IBM Ethernet Switch B24X also comes with a single fan tray consisting of three variable-speed fans.  
If one fan within the fan tray fails it does not affect the operation of the other fans in the unit. The fan tray  
is hot-swappable, increasing device availability and serviceability.  
Figure 9. IBM Ethernet Switch B24X rear view (fans and power supply)  
IBM Ethernet Switch B24X  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The airflow of the switch is primarily port/side (front) to non-port (back) side. Air is drawn into the system  
from vents on the front and front sides of the switch and expelled out the rear. The cooling characteristics  
of the system allow it to be deployed in server racks featuring hot-cold aisle containment without the need  
of special baffling.  
Figure 10. IBM Ethernet Switch B24X airflow  
Installation  
The IBM Ethernet Switch B24X comes with two rack-mount brackets affixed to each side for installation  
into an EIA-310D compliant rack. Screws for mounting the B24X to the rack are not included with the  
switch. Allow at least 3 inches of space at the front, back, and sides of the device for proper cabling and  
cooling  
Figure 11. IBM Ethernet Switch B24X rack mount kit  
Network cabling requirements  
The network cables required for the IBM Ethernet Switch B24X are:  
z
10GBASE-SR SFP+ transceiver [69Y0389]  
z
840 to 860 nm wavelength using multi-mode fiber cable, LC duplex connector. Operating  
distance supported depends on the multi-mode fiber cable used. See Table 11.  
z
z
1000BASE-T (built-in 10/100/1000 MbE RJ-45 ports) and 1000BASE-TX SFP transceiver: up to 100  
m over UTP Category 5e or higher cabling, RJ-45 connector.  
DB9 male serial console port: DB9 female-to-DB9 female straight-through serial console cable that  
comes with the switch.  
IBM Ethernet Switch B24X  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 11. Multi-mode fiber cable distances supported  
Multi-mode fiber cable  
62.5 ìm (160 MHz*km)  
62.5 ìm (200 MHz*km)  
50 ìm (400 MHz*km)  
50 ìm (500 MHz*km)  
50 ìm (2000 MHz*km)  
Distance  
Loss  
26 m  
33 m  
66 m  
82 m  
300 m  
1.6 dBm  
1.6 dBm  
1.7 dBm  
1.8 dBm  
2.6 dBm  
Related links  
For more information, see the following resources:  
z
z
z
IBM System x network options support site for model-type 0563 – code download and documentation  
0563  
IBM Redbooks publication IBM b-type Data Center Networking: Design and Best Practices  
Introduction, SG24-7786  
IBM Redbooks publication IBM b-type Data Center Networking: Product Introduction and Initial Setup,  
SG24-7785  
·
IBM Ethernet Switch B48Y product page  
z
IBM Ethernet Switch B24X product page  
z
z
z
z
IBM Configuration and Options Guide  
IBM Smarter Networks  
IBM b-type Ethernet switches and routers  
IBM Ethernet Switch B24X  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notices  
This information was developed for products and services offered in the U.S.A.  
IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local  
IBM representative for information on the products and services currently available in your area. Any reference to an  
IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may  
be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property  
right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM  
product, program, or service. IBM may have patents or pending patent applications covering subject matter described  
in this document. The furnishing of this document does not give you any license to these patents. You can send  
license inquiries, in writing, to:  
IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A.  
The following paragraph does not apply to the United Kingdom or any other country where such provisions  
are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS  
PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT  
NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS  
FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain  
transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or  
typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in  
new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s)  
described in this publication at any time without notice.  
Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner  
serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this  
IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you  
supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM  
products was obtained from the suppliers of those products, their published announcements or other publicly  
available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility  
or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be  
addressed to the suppliers of those products. This information contains examples of data and reports used in daily  
business operations. To illustrate them as completely as possible, the examples include the names of individuals,  
companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses  
used by an actual business enterprise is entirely coincidental.  
Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained  
in other operating environments may vary significantly. Some measurements may have been made on  
development-level systems and there is no guarantee that these measurements will be the same on generally  
available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results  
may vary. Users of this document should verify the applicable data for their specific environment.  
COPYRIGHT LICENSE:  
This information contains sample application programs in source language, which illustrate programming techniques  
on various operating platforms. You may copy, modify, and distribute these sample programs in any form without  
payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to  
the application programming interface for the operating platform for which the sample programs are written. These  
examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability,  
serviceability, or function of these programs.  
© Copyright International Business Machines Corporation 2010. All rights reserved.  
Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by  
GSA ADP Schedule Contract with IBM Corp.  
IBM Ethernet Switch B24X  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
This document was created or updated on November 9, 2010.  
Send us your comments in one of the following ways:  
z
Use the online Contact us review form found at:  
ibm.com/redbooks  
z
z
Send your comments in an e-mail to:  
Mail your comments to:  
IBM Corporation, International Technical Support Organization  
Dept. HYTD Mail Station P099  
2455 South Road  
Poughkeepsie, NY 12601-5400 U.S.A.  
This document is available online at http://www.ibm.com/redbooks/abstracts/tips0785.html .  
Trademarks  
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business  
Machines Corporation in the United States, other countries, or both. These and other IBM trademarked  
terms are marked on their first occurrence in this information with the appropriate symbol (® or ™),  
indicating US registered or common law trademarks owned by IBM at the time this information was  
published. Such trademarks may also be registered or common law trademarks in other countries. A  
The following terms are trademarks of the International Business Machines Corporation in the United  
States, other countries, or both:  
BladeCenter®  
IBM®  
MVS™  
Redbooks®  
Redpaper™  
Redbooks (logo)®  
System i®  
System p®  
System Storage®  
System x®  
The following terms are trademarks of other companies:  
Microsoft, and the Windows logo are trademarks of Microsoft Corporation in the United States, other  
countries, or both.  
UNIX is a registered trademark of The Open Group in the United States and other countries.  
Linux is a trademark of Linus Torvalds in the United States, other countries, or both.  
Other company, product, or service names may be trademarks or service marks of others.  
IBM Ethernet Switch B24X  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Building Set T25101 User Manual
Haier Dishwasher DW9 AFM ME User Manual
Haier Washer HWM 100 AS BS User Manual
Hamilton Beach Blender 840119400 User Manual
Hasbro Stereo Amplifier OX4 User Manual
Havis Shields DVR PT VIDEO MDVR User Manual
Honeywell Thermostat TL5110 User Manual
Husqvarna Trimmer H348SL User Manual
Ice O Matic Ice Maker EMF 2306 User Manual
IKEA Indoor Furnishings AA 173891 1 User Manual