IBM Network Card DS4000 FC User Manual

IBM System Storage DS4000 FC 4Gbps PCI-X  
Single/Dual Port HBA  
ꢀꢁꢂ  
Installation and User’s Guide  
GC26-7814-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IBM System Storage DS4000 FC 4Gbps PCI-X  
Single/Dual Port HBA  
ꢀꢁꢂ  
Installation and User’s Guide  
GC26-7814-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: Before using this information and the product it supports, be sure to read the general information under Appendix B,  
First Edition (March 2006)  
© Copyright International Business Machines Corporation 2006. All rights reserved.  
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract  
with IBM Corp.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
© Copyright IBM Corp. 2006  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iv IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
vi IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
viii IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tables  
© Copyright IBM Corp. 2006  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
x
IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety  
Before installing this product, read the Safety Information.  
Antes de instalar este produto, leia as Informações de Segurança.  
Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí.  
Læs sikkerhedsforskrifterne, før du installerer dette produkt.  
Lees voordat u dit product installeert eerst de veiligheidsvoorschriften.  
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.  
Avant d’installer ce produit, lisez les consignes de sécurité.  
Vor der Installation dieses Produkts die Sicherheitshinweise lesen.  
Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza.  
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet.  
Antes de instalar este produto, leia as Informações sobre Segurança.  
© Copyright IBM Corp. 2006  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Antes de instalar este producto, lea la información de seguridad.  
Läs säkerhetsinformationen innan du installerar den här produkten.  
Statement 1:  
DANGER  
Electrical current from power, telephone, and communication cables is  
hazardous.  
To avoid a shock hazard:  
v Do not connect or disconnect any cables or perform installation,  
maintenance, or reconfiguration of this product during an electrical  
storm.  
v Connect all power cords to a properly wired and grounded electrical  
outlet.  
v Connect to properly wired outlets any equipment that will be attached to  
this product.  
v When possible, use one hand only to connect or disconnect signal  
cables.  
v Never turn on any equipment when there is evidence of fire, water, or  
structural damage.  
v Disconnect the attached power cords, telecommunications systems,  
networks, and modems before you open the device covers, unless  
instructed otherwise in the installation and configuration procedures.  
v Connect and disconnect cables as described in the following table when  
installing, moving, or opening covers on this product or attached  
devices.  
To Connect:  
To Disconnect:  
1. Turn everything OFF.  
1. Turn everything OFF.  
2. First, attach all cables to devices.  
3. Attach signal cables to connectors.  
4. Attach power cords to outlet.  
5. Turn device ON.  
2. First, remove power cords from outlet.  
3. Remove signal cables from connectors.  
4. Remove all cables from devices.  
Statement 2:  
xii IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION:  
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or  
transmitters) are installed, note the following:  
v Do not remove the covers. Removing the covers of the laser product could  
result in exposure to hazardous laser radiation. There are no serviceable  
parts inside the device.  
v Use of controls or adjustments or performance of procedures other than  
those specified herein might result in hazardous radiation exposure.  
DANGER  
Some laser products contain an embedded Class 3A or Class 3B laser  
diode. Note the following.  
Laser radiation when open. Do not stare into the beam, do not view directly  
with optical instruments, and avoid direct exposure to the beam.  
Class 1 Laser Statement  
Class 1 Laser Product  
Laser Klasse 1  
Laser Klass 1  
Luokan 1 Laserlaite  
`
Appareil A Laser de Classe 1  
IEC 825-11993 CENELEC EN 60 825  
Statement 3:  
CAUTION:  
Handling the cord on this product, or cords associated with accessories sold  
with this product, will expose you to lead, a chemical known to the State of  
California to cause cancer and birth defects or other reproductive harm. Wash  
hands after handling.  
Safety xiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xiv IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About this document  
This book provides instructions for installing and customizing the configuration of  
your IBM System StorageDS4000 FC 4Gbps PCI-X Single/Dual Port HBA and  
connected devices. It also provides information on troubleshooting your IBM System  
Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA.  
Who should read this document  
This document is intended for system operators and service technicians who have  
extensive knowledge of fibre channel and network technology.  
FAStT product renaming  
IBM® has renamed some FAStT family products. Table 1 identifies each DS4000  
product name with its corresponding previous FAStT product name. Note that this  
change of product name only indicates no change in functionality or warranty. All  
products listed below with new names are functionally-equivalent and  
fully-interoperable. Each DS4000 product retains full IBM service as outlined in  
service contracts issued for analogous FAStT products.  
Table 1. Mapping of FAStT names to DS4000 Series names  
Previous FAStT Product Name  
IBM TotalStorage® FAStT Storage Server  
FAStT  
Current DS4000 Product Name  
IBM TotalStorage DS4000  
DS4000  
FAStT Family  
DS4000 Mid-range Disk System  
FAStT Storage Manager vX.Y (for example  
v9.10)  
DS4000 Storage Manager vX.Y (for example  
v9.10)  
FAStT100  
DS4100  
FAStT600  
DS4300  
FAStT600 with Turbo Feature  
FAStT700  
DS4300 Turbo  
DS4400  
FAStT900  
DS4500  
EXP700  
DS4000 EXP700  
DS4000 EXP710  
DS4000 EXP100  
FlashCopy for DS4000  
VolumeCopy for DS4000  
Enhanced Remote Mirroring for DS4000  
Metro Mirroring for DS4000  
EXP710  
EXP100  
FAStT FlashCopy®  
FAStT VolumeCopy  
FAStT Remote Mirror (RM)  
FAStT Synchronous Mirroring  
Global Copy for DS4000  
(New Feature = Asynchronous Mirroring  
without Consistency Group)  
Global Mirroring for DS4000  
(New Feature = Asynchronous Mirroring with  
Consistency Group)  
© Copyright IBM Corp. 2006  
xv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4000 Storage Subsystem installation tasks - General overview  
Table 2 provides a sequential list of many installation and configuration tasks that  
are common to most DS4000 configurations. When you install and configure your  
DS4000 storage subsystem, refer to this table to find the documentation that  
explains how to complete each task.  
See also: The DS4000 Storage Server and Storage Expansion Enclosure Quick  
Start Guide provides an excellent overview of the installation process.  
Table 2. Where to find DS4000 installation and configuration procedures  
Installation task  
Where to find information or procedures  
1
Plan the installation  
v DS4000 Storage Manager Concepts Guide  
v DS4000 Storage Manager Installation and Support Guide for  
AIX, HP-UX, Solaris and Linux on POWER  
v DS4000 Storage Manager Installation and Support Guide for  
Windows 2000/Server 2003, NetWare, ESX Server, and  
Linux  
v DS4100 Storage Server Installation, User’s, and Maintenance  
Guide  
v DS4300 Fibre Channel Storage Server Installation and User’s  
Guide  
v DS4400 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4500 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4800 Storage Subsystem Installation, User’s, and  
Maintenance Guide  
2
3
Mount the DS4000  
storage subsystem in  
the rack  
v DS4800 Installation, User’s, and Maintenance Guide  
v DS4400 and DS4500 Rack Mounting Instructions  
v DS4300 Rack Mounting Instructions  
v DS4100 Installation, User’s and Maintenance Guide  
Mount the DS4000  
EXP storage  
expansion unit in the  
rack  
v DS4000 EXP100 Storage Expansion Unit Installation, User’s  
and Maintenance Guide  
v DS4000 EXP700 and EXP710 Storage Expansion Enclosures  
Installation, User’s, and Maintenance Guide  
v DS4000 EXP810 Storage Expansion Enclosures Installation,  
User’s, and Maintenance Guide  
v FAStT EXP500 Installation and User’s Guide  
4
5
Route the storage  
expansion unit Fibre  
Channel cables  
v DS4100 Fibre Channel Cabling Instructions  
v DS4300 Fibre Channel Cabling Instructions  
v DS4400 Fibre Channel Cabling Instructions  
v DS4500 Fibre Channel Cabling Instructions  
v DS4800 Installation, User’s, and Maintenance Guide  
Route the host  
server Fibre Channel  
cables  
v DS4100 Fibre Channel Cabling Instructions  
v DS4300 Fibre Channel Cabling Instructions  
v DS4400 Fibre Channel Cabling Instructions  
v DS4500 Fibre Channel Cabling Instructions  
v DS4800 Installation, User’s, and Maintenance Guide  
xvi IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 2. Where to find DS4000 installation and configuration procedures (continued)  
Installation task  
Where to find information or procedures  
6
Power up the  
subsystem  
v DS4100 Storage Server Installation, User’s, and Maintenance  
Guide  
v DS4300 Fibre Channel Storage Server Installation and User’s  
Guide  
v DS4400 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4500 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4800 Storage Subsystem Installation, User’s, and  
Maintenance Guide  
7
Configure DS4000  
network settings  
v DS4100 Storage Server Installation, User’s, and Maintenance  
Guide  
v DS4300 Fibre Channel Storage Server Installation and User’s  
Guide  
v DS4400 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4500 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4800 Storage Subsystem Installation, User’s, and  
Maintenance Guide  
8
Zone the fabric  
switch  
(SAN-attached only)  
v DS4000 Storage Manager Installation and Support Guide for  
AIX, HP-UX, Solaris and Linux on POWER  
v DS4000 Storage Manager Installation and Support Guide for  
Windows 2000/Server 2003, NetWare, ESX Server, and  
Linux  
v DS4000 Storage Manager Copy Services Guide (describes  
switch zoning for the Remote Mirror Option)  
v See also the documentation provided by the switch  
manufacturer  
9
Install DS4000  
v DS4000 Storage Manager Installation and Support Guide for  
Storage Manager  
software on the  
management station  
AIX, HP-UX, Solaris and Linux on POWER  
v DS4000 Storage Manager Installation and Support Guide for  
Windows 2000/Server 2003, NetWare, ESX Server, and  
Linux  
10 Install host software  
(failover drivers) on  
host server  
v DS4000 Storage Manager online help (for post-installation  
tasks)  
11 Start DS4000  
Storage Manager  
12 Set the DS4000  
Storage Manager  
clock  
13 Set the DS4000  
Storage Manager  
host default type  
About this document xvii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table 2. Where to find DS4000 installation and configuration procedures (continued)  
Installation task  
Where to find information or procedures  
14 Verify DS4000  
v DS4100 Storage Server Installation, User’s, and Maintenance  
subsystem health  
Guide  
v DS4300 Fibre Channel Storage Server Installation and User’s  
Guide  
v DS4400 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4500 Fibre Channel Storage Server Installation and  
Support Guide  
v DS4800 Storage Subsystem Installation, User’s, and  
Maintenance Guide  
15 Enable DS4000  
Storage Manager  
premium feature  
keys  
Copy Services premium features  
DS4000 Storage Manager Copy Services Guide  
FC/SATA Intermix premium feature  
DS4000 Fibre Channel and Serial ATA Intermix  
Premium Feature Installation Overview  
Storage Partitioning (and general premium features  
information)  
v DS4000 Storage Manager Concepts Guide  
v DS4000 Storage Manager Installation and Support  
Guide for AIX, HP-UX, Solaris and Linux on POWER  
v DS4000 Storage Manager Installation and Support  
Guide for Windows 2000/Server 2003, NetWare,  
ESX Server, and Linux  
16 Configure arrays and  
v DS4000 Storage Manager Installation and Support Guide for  
logical drives  
AIX, HP-UX, Solaris and Linux on POWER  
17 Configure host  
v DS4000 Storage Manager Installation and Support Guide for  
Windows 2000/Server 2003, NetWare, ESX Server, and  
Linux  
partitions  
18 Verify host access to  
v DS4000 Storage Manager online help  
DS4000 storage  
Getting information, help, and service  
If you need help, service, or technical assistance or just want more information  
about IBM products, you will find a wide variety of sources available from IBM to  
assist you. This section contains information about where to go for additional  
information about IBM and IBM products, what to do if you experience a problem  
with your IBM Eserver xSeries® or IntelliStation® system, and whom to call for  
service, if it is necessary.  
Before you call  
Before you call, make sure that you have taken these steps to try to solve the  
problem yourself:  
v Check all cables to make sure that they are connected.  
v Check the power switches to make sure that the system is turned on.  
v Use the troubleshooting information in your system documentation and use the  
diagnostic tools that come with your system.  
xviii IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
v Check for technical information, hints, tips, and new device drivers at the  
following Web site:  
v Use an IBM discussion forum on the IBM Web site to ask questions.  
You can solve many problems without outside assistance by following the  
troubleshooting procedures that IBM provides in the online help or in the documents  
that are provided with your system and software. The information that comes with  
your system also describes the diagnostic tests that you can perform. Most xSeries  
and IntelliStation systems, operating systems, and programs come with information  
that contains troubleshooting procedures and explanations of error messages and  
error codes. If you suspect a software problem, see the information for the  
operating system or program.  
Using the documentation  
Information about the xSeries or IntelliStation system and preinstalled software, if  
any, is available in the documents that come with your system. This includes printed  
documents, online documents, readme files, and help files. See the troubleshooting  
information in your system documentation for instructions on how to use the  
diagnostic programs. The troubleshooting information or the diagnostic programs  
might tell you that you need additional or updated device drivers or other software.  
Web sites  
IBM maintains pages on the World Wide Web where you can get the latest  
technical information and download device drivers and updates.  
v For DS4000 information, go to the following Web site:  
The support page has many sources of information and ways for you to solve  
problems, including:  
– Diagnosing problems using the IBM Online Assistant  
– Downloading the latest device drivers and updates for your products  
– Viewing frequently asked questions (FAQ)  
– Viewing hints and tips to help you solve problems  
– Participating in IBM discussion forums  
– Setting up e-mail notification of technical updates about your products  
v You can order publications through the IBM Publications Ordering System at the  
following Web site:  
v For the latest information about IBM xSeries products, services, and support, go  
to the following Web site:  
v For the latest information about IBM pSeries® products, services, and support, go  
to the following Web site:  
v For the latest information about the IBM IntelliStation information, go to the  
following Web site:  
About this document xix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
v For the latest information about operating system and HBA support, clustering  
support, SAN fabric support, and Storage Manager feature support, see the  
TotalStorage DS4000 Interoperability Matrix at the following Web site:  
Software service and support  
Through IBM Support Line, for a fee you can get telephone assistance with usage,  
configuration, and software problems with xSeries servers, IntelliStation  
workstations, and appliances. For information about which products are supported  
by Support Line in your country or region, go to the following Web site:  
For more information about the IBM Support Line and other IBM services, go to the  
following Web sites:  
Hardware service and support  
You can receive hardware service through IBM Integrated Technology Services or  
through your IBM reseller, if your reseller is authorized by IBM to provide warranty  
service. Go to the following Web site for support telephone numbers:  
In the U.S. and Canada, hardware service and support is available 24 hours a day,  
7 days a week. In the U.K., these services are available Monday through Friday,  
from 9 a.m. to 6 p.m.  
Fire suppression systems  
A fire suppression system is the responsibility of the customer. The customer’s own  
insurance underwriter, local fire marshal, or a local building inspector, or both,  
should be consulted in selecting a fire suppression system that provides the correct  
level of coverage and protection. IBM designs and manufactures equipment to  
internal and external standards that require certain environments for reliable  
operation. Because IBM does not test any equipment for compatibility with fire  
suppression systems, IBM does not make compatibility claims of any kind nor does  
IBM provide recommendations on fire suppression systems.  
How to send your comments  
Your feedback is important in helping us to provide the most accurate and  
high-quality information. If you have comments or suggestions for improving this  
publication, you can send us comments electronically by using these addresses:  
v Internet: [email protected]  
v IBMLinkfrom U.S.A.: STARPUBS at SJEVM5  
v IBMLink from Canada: STARPUBS at TORIBM  
v IBM Mail Exchange: USIB3WD at IBMMAIL  
Be sure to include the name and order number of the document and, if applicable,  
the specific location of the text you are commenting on, such as a page number or  
table number.  
xx IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
You can also mail your comments by using the Reader Comment Form in the back  
of this manual or direct your mail to:  
International Business Machines Corporation  
Information Development  
Dept. GZW  
9000 South Rita Road  
Tucson, AZ 85744–0001  
U.S.A.  
When you send information to IBM, you grant IBM a nonexclusive right to use or  
distribute the information in any way it believes appropriate without incurring any  
obligation to you.  
How this book is organized  
PCI-X Single/Dual Port HBA,” on page 1 describes the IBM System Storage  
DS4000 FC 4Gbps PCI-X Single/Dual Port HBA. This chapter includes an overview  
of the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA  
features and contains the information and instructions needed to prepare and install  
the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA.  
BIOS code,” on page 9 provides information for updating the IBM System Storage  
DS4000 FC 4Gbps PCI-X Single/Dual Port HBA BIOS code.  
provides detailed configuration information for users who want to customize the  
configuration of the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port  
HBA and connected Fibre Channel devices.  
page 29 contains the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual  
Port HBA operating environment and specification information.  
Chapter 5, “Troubleshooting,” on page 31 covers the types of installation problems  
that can cause the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port  
HBA to function incorrectly.  
Appendix A, “Accessibility,” on page 33 provides information about alternate  
keyboard navigation, which is a DS4000 Storage Manager accessibility feature.  
Accessibility features help a user who has a physical disability, such as restricted  
mobility or limited vision, to use software products successfully.  
Appendix B, “Notices,” on page 35 provides product notices.  
39 provides information about European standards for recycling and disposal.  
proper disposal and/or recycling of batteries.  
Appendix E, “Cable Warning,” on page 43 discloses the possible hazards  
associated with handling cables for this product or cords associated with  
accessories sold with this product.  
About this document xxi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
other DS4000 publications.  
xxii IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notices used in this document  
The caution and danger statements used in this book also appear in the multilingual  
Safety Information book provided with your IBM System Storage DS4000 FC 4Gbps  
PCI-X Single/Dual Port HBA. Each caution and danger statement is numbered for  
easy reference to the corresponding statements in the safety book.  
The following types of notices and statements are used in this book:  
v Note: These notices provide important tips, guidance, or advice.  
v Important: These notices provide information or advice that might help you avoid  
inconvenient or problem situations.  
v Attention: These notices indicate possible damage to programs, devices, or  
data. An attention notice is placed just before the instruction or situation in which  
damage could occur.  
v Caution: These statements indicate situations that can be potentially hazardous  
to you. A caution statement is placed just before the description of a potentially  
hazardous procedure step or situation.  
v Danger: These statements indicate situations that can be potentially lethal or  
extremely hazardous to you. A danger statement is placed just before the  
description of a potentially lethal or extremely hazardous procedure step or  
situation.  
About this document xxiii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
xxiv IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1. Preparing and installing the IBM System Storage  
DS4000 FC 4Gbps PCI-X Single/Dual Port HBA  
This chapter contains instructions for preparing and installing the IBM System  
Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA and describes the adapter  
components. The IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port  
HBA is referred to throughout this book as the FC 4Gbps PCI-X Adapter.  
Overview  
The IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA is a  
4Gbps high-performance, direct memory access (DMA), bus master, Fibre Channel  
host adapter designed for high-end systems. The function and performance are  
derived from the ISP2422 chip (see Figure 2 on page 4) making this FC 4Gbps  
PCI-X Adapter a leading-edge host adapter.  
The ISP2422 chip combines a powerful, reduced instruction set computer (RISC)  
processor, a Fibre Channel protocol manager (FPM) with one 4 GB Fibre Channel  
transceiver, and a peripheral component interconnect (PCI) or peripheral component  
interconnect-extended (PCI-X) local bus interface in a single-chip solution. The FC  
4Gbps PCI-X Adapter supports all Fibre Channel (FC) peripheral devices that  
support private-loop direct attach (PLDA) and fabric-loop attach (FLA).  
The FC 4Gbps PCI-X Adapter connects the following:  
v Mainframe computers  
v Super computers  
v Workstations  
v Storage devices  
v Servers  
Fibre Channel defined  
Fibre Channel technology is outlined in the SCSI-3 Fibre Channel Protocol  
(SCSI-FCP) standard. Fibre Channel is a high-speed data transport technology  
used for mass storage and networking.  
Using a Fibre Channel Arbitrated loop (FC-AL), 126 Fibre Channel devices can be  
supported, compared to 15 small computer system interface (SCSI) devices with  
Ultra SCSI.  
The FC 4Gbps PCI-X Adapter uses a multimode shortwave optical interface for  
distances up to 500 meters when operating at 1Gbps, 300 meters when operating  
at 2Gbps, and 150 meters when operating at 4Gbps.  
The FC 4Gbps PCI-X Adapter is a 4Gbps Fibre Channel device that supports data  
transfer rates up to 400MB per second half-duplex and 800MB per second  
full-duplex on optical interfaces.  
© Copyright IBM Corp. 2006  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FC 4Gbps PCI-X Adapter features  
The FC 4Gbps PCI-X Adapter has the following features:  
v 64-Bit, PCI-X 2.0 266 MHz, compatible with 66/33 MHz PCI and 133/100/66 MHz  
PCI-X.  
v Conforms to PCI Local Bus Specification, revision 2.3 and 3.0, PCI-X Protocol  
Addendum to the PCI Local Bus Specification, revision 2.0a, PCI-X Electrical and  
Mechanical Addendum (revision 2.0a) to the PCI Local Bus Specification, PCI  
Bus Power Management Interface Specification revision 1.1, PCI Hot Plug  
Specification, revision 1.0.  
v Compliance with SCSI-3 Fibre Channel Protocol (SCSI-FCP), Fibre Channel  
Physical and Signaling Interface (FC-PH), Fibre Channel 2nd Generation  
(FC-PH-2), Third Generation Fibre Channel Physical and Signaling Interface  
(FC-PH-3), Fibre Channel-Arbitrated Loop (FC-AL-2), Fibre Channel Fabric Loop  
Attachment Technical Report (FC-FLA), Fibre Channel-Private Loop Direct Attach  
Technical Report (FC-PLDA), Fibre Channel Tape (FC-TAPE) profile, SCSI Fibre  
Channel Protocol-2 (FCP-2), Second Generation FC Generic Services  
(FC-GS-3), Third Generation FC Generic Services (FC-GS-3), Fibre Channel  
Framing and Signaling (FC-FS) Physical Specification.  
v Compliance with U.S. and international safety and emissions standards.  
v Support for 4/2/1Gbps auto-negotiation (4.2480/2.1240/1.0625 Gbps) data rates.  
v Support for 100,000 IOPS and higher.  
v Support for 400 MBps maximum at half-duplex, 800 MBps maximum at  
full-duplex.  
v Fast!UTIL basic input/output system (BIOS) utility program to customize the  
configuration parameters on the FC 4Gbps PCI-X Adapter and attached drives.  
v Support for Point-to-point (N_Port), arbitrated loop (NL_Port), and switched fabric  
(N_Port), Support for F_Port and FL_Port login. 2,048 concurrent logins and  
2,048 active exchanges.  
v Support for Fibre Channel service (Classes 2 and 3).  
v Support for Fibre Channel protocols FCP (SCSI-FCP), IP (FC-IP), FICON®  
(FC-SB-2), FC-TAPE (FCP-2).  
v Storage Networking industry association (SNIA) HBA application programming  
interface (API), and storage management interface specification (SMI-S)  
compliant.  
v Managed by the SANsurfer® FC HBA Manager.  
Preinstallation procedures  
Before you begin the FC 4Gbps PCI-X Adapter installation, do the following:  
v Write down the serial number of the FC 4Gbps PCI-X Adapter. Each adapter has  
a unique serial number. If the nonvolatile random access memory (NVRAM) (also  
referred to as NOVRAM) is damaged, the system prompts you for the FC 4Gbps  
PCI-X Adapter serial number. Figure 1 on page 3 shows the serial number label  
location.  
2
IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
2
3
4
Figure 1. FC 4Gbps PCI-X Adapter serial number label  
Components shown in Figure 2:  
1. Yellow, Green, and Amber LEDs for port 1  
2. Port 1 (top), port 2 (bottom)  
Note: Port 2 and LEDs for port 2 are for the dual port FC 4Gbps PCI-X Adapter  
only.  
3. Yellow, Green, and Amber LEDs for port 2  
4. Serial number label  
Handling static-sensitive devices  
Attention: Static electricity can damage electronic devices and your system. To  
avoid damage, keep static-sensitive devices in their static-protective package until  
you are ready to install them.  
To reduce the possibility of electrostatic discharge, observe the following  
precautions:  
v Limit your movement. Movement can cause static electricity to build up around  
you.  
v Handle the device carefully, holding it by its edges or its frame.  
v Do not touch solder joints, pins, or exposed printed circuitry.  
v Do not leave the device where others can handle and possibly damage the  
device.  
v While the device is still in its static-protective package, touch it to an unpainted  
metal part of the system unit for at least 2 seconds. (This drains static electricity  
from the package and from your body.)  
v Remove the device from its package and install it directly into your system unit  
without setting it down. If it is necessary to set the device down, place it in its  
static-protective package. Do not place the device on your system unit cover or  
on a metal table.  
Chapter 1. Preparing and installing the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
v Take additional care when handling devices during cold weather because heating  
reduces indoor humidity and increases static electricity.  
What you need for the installation  
To install the FC 4Gbps PCI-X Adapter in your server, you will need a small Phillips  
screwdriver. Depending on your configuration, you might need the following two  
items:  
v An LC-LC Fibre Channel Cable1 (enables you to connect Fibre Channel nodes to  
a loop)  
v LC-SC Fibre Channel Cable1 (enables you to connect an LC-LC Fibre Channel  
cable to a device that requires an SC connector)  
FC 4Gbps PCI-X Adapter components  
Figure 2 identifies the FC 4Gbps PCI-X Adapter components that are referred to in  
this book.  
4
1
2
3
Figure 2. FC 4Gbps PCI-X Adapter components  
Components shown in Figure 3:  
1. Yellow, Green, and Amber LEDs for port 1  
2. Port 1 (top), port 2 (bottom)  
Note: Port 2 and the LEDs for port 2 are for the dual port adapter, only.  
3. Yellow, Green, and Amber LEDs for port 2  
4. ISP2422  
1. This option does not come with the FC 4Gbps PCI-X Host Bus Adapter. It must be ordered separately.  
4
IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 3 describes the yellow, green, and amber light emitting diodes (LEDs) and the  
activity of the FC 4Gbps PCI-X Adapter. For more information about the FC 4Gbps  
PCI-X Adapter LED activity, see the IBM System Storage DS4000 Problem  
Determination Guide.  
Table 3. FC 4Gbps PCI-X Adapter activity  
Yellow LED  
Green LED  
Amber LED  
Activity  
Description  
Off  
Off  
Off  
Power off  
The server adapter is not receiving  
power. The server is powered off.  
On  
On  
On  
Power on (before  
The FC 4Gbps PCI-X Adapter is  
firmware initialization) receiving power from the PCI or  
PCI-X slot but is not initialized by  
the adapter firmware.  
Flashing  
Flashing  
Flashing  
Power on (after  
The FC 4Gbps PCI-X Adapter is  
firmware initialization) successfully initialized by the  
adapter firmware and is in a ready  
state. The adapter firmware is  
initialized when the adapter BIOS  
code is loaded, Ctrl-Q is pressed, or  
the operating system driver is  
loaded.  
Flashing  
alternately  
Flashing  
alternately  
Flashing  
alternately  
Firmware error  
The FC 4Gbps PCI-X Adapter  
firmware has detected an  
unrecoverable error condition.  
Off  
Off  
On/Flashing  
Off  
Online  
Online  
Online  
Beacon  
1Gbps link / I/O activity  
2Gbps link / I/O activity  
4Gbps link / I/O activity  
Off  
On/Flashing  
On/Flashing  
Flashing  
Off  
Off  
Off  
Flashing  
The adapter is responding to a  
Beacon command from an HBA  
management program.  
Chapter 1. Preparing and installing the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the FC 4Gbps PCI-X Adapter  
Attention: To avoid damage to your fiber-optic cables, follow these guidelines:  
v Do not route the cable along a folding cable-management arm.  
v
For devices on slide rails, leave enough slack in the cables so that they do not  
bend to a diameter of less than 76 mm (3 in.) or to a radius less than 38 mm  
(1.5 in.) when extended or become pinched when retracted.  
v Route the cable away from places where it can be damaged by other devices in  
the rack cabinet.  
v Do not use plastic cable ties in place of the provided cable straps.  
v Do not overtighten the cable straps or bend the cables to a diameter of less than  
76 mm (3 in.) or a radius less than 38 mm (1.5 in.).  
v Do not put excess weight on the cable at the connection point. Be sure that the  
cable is well supported.  
v The following are the recommended maximum cable lengths.  
– 1Gbps: 500 meters 50/125 µm fiber, 300 meters 62.5/125 µm fiber  
– 2Gbps: 300 meters 50/125 µm fiber, 150 meters 62.5/125 µm fiber  
– 4Gbps: 150 meters 50/125 µm fiber, 70 meters 62.5/125 µm fiber  
CAUTION:  
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or  
transmitters) are installed, note the following:  
v Do not remove the covers. Removing the covers of the laser product could  
result in exposure to hazardous laser radiation. There are no serviceable  
parts inside the device.  
v Use of controls or adjustments or performance of procedures other than  
those specified herein might result in hazardous radiation exposure.  
DANGER  
Some laser products contain an embedded Class 3A or Class 3B laser  
diode. Note the following.  
Laser radiation when open. Do not stare into the beam, do not view directly  
with optical instruments, and avoid direct exposure to the beam.  
The FC 4Gbps PCI-X Adapter comes with an attached standard 3U adapter bracket  
as shown in Figure 2 on page 4. An additional Low Profile 2U bracket also comes  
with the adapter. Before you install the FC 4Gbps PCI-X Adapter, verify whether you  
need the Fibre Channel Low Profile 2U adapter bracket. If you need to install the  
Low Profile 2U bracket, continue with step 1. Otherwise, go to step 2.  
1. Complete the following steps to install the Fibre Channel Low Profile 2U  
adapter bracket:  
6
IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
a. Remove your FC 4Gbps PCI-X Adapter from the static-protective package.  
Set the adapter down on a nonconductive, static-protected surface (place it  
component side up). Do not place the adapter on your system unit cover or  
on a metal table.  
b. Use your small Phillips (#1) screwdriver to carefully remove the two bracket  
screws from your 3U adapter, (you will reuse the two adapter screws).  
Take off the 3U bracket and set it aside.  
c. Align the two screw holes in the 2U adapter bracket with the two screws  
holes on the adapter. Using the two screws you removed in step 1a,  
secure the bracket to the adapter.  
d. Return the adapter to the static-protective package until you are ready for  
installation.  
2. Check the system board and make any configuration changes needed to  
accommodate the FC 4Gbps PCI-X Adapter.  
Note: The FC 4Gbps PCI-X Adapter is self-configuring; however, some  
system boards require manual configuration. For example, some  
systems have a PCI Device Configuration menu in the system board  
setup BIOS code where you must enable host adapters, bus-master  
slots, and interrupt request (IRQ) levels. If the system board supports  
triggering, use level triggering for the FC 4Gbps PCI-X Adapter. For  
system specific configuration, refer to the documentation that comes  
with your server, or contact your IBM technical support representative to  
determine if your system board requires configuration.  
3. Turn off the peripheral devices. Then, turn off the server.  
4. Disconnect the power cords.  
5. Remove the server cover.  
6. Choose a PCI bus-master slot that supports bus mastering. Most system  
boards automatically assign an IRQ level and interrupt line. If your system  
board does not automatically assign an IRQ level and interrupt line, you must  
assign an IRQ level and use interrupt line A for this PCI bus-master slot.  
Before installing your adapter into a PCI bus-master slot, note the following:  
v Some system boards have two kinds of PCI bus slots: master and  
subordinate. The FC 4Gbps PCI-X Adapter must be in a PCI bus-master  
slot. (Some system boards have PCI bus-master slots that are shared with  
on-board devices. The FC 4Gbps PCI-X Adapter does not work in shared  
PCI bus-master slots.)  
v PCI connectors vary among system board manufacturers. The FC 4Gbps  
PCI-X Adapter is a 64-Bit PCI device that can function in a 32-Bit PCI  
bus-master slot.  
v The FC 4Gbps PCI-X Adapter is designed and tested to operate at PCI bus  
speeds up to 66 MHz and PCI-X bus speeds up to 266 MHz.  
v PCI and PCI-X slots look the same. If the server contains both PCI and  
PCI-X bus-master slots, refer to the documentation that comes with the  
server to determine the slot type.  
7. Remove the expansion slot cover. Before you remove the cover, refer to the  
documentation that comes with the server for specific removal instructions.  
Attention: If you try to install the FC 4Gbps PCI-X Adapter into a PCI  
bus-master slot that does not conform to the PCI specification, you might  
damage the FC 4Gbps PCI-X Adapter.  
8. Align the adapter with the expansion slot. Carefully press the adapter into the  
PCI bus-master slot until it is fully seated and secure.  
Chapter 1. Preparing and installing the IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
9. Connect one end of an LC-LC Fibre Channel cable to the optical interface  
connector on the FC 4Gbps PCI-X Adapter. Connect the other end to a Fibre  
Channel device.  
10. Carefully install and secure the server cover.  
11. Connect the power cables.  
12. Turn on all external Fibre Channel devices; then, turn on the server. The  
following information is displayed if the server has an Intel® 32-Bit processor  
(IA-32), Intel Extended Memory 64-Bit Technology (EM64T) processor, or an  
Advanced Micro Devices 64-Bit (AMD-64) architecture:  
Note: This BIOS banner does not display when the adapter is in a server with  
an Intel 64-Bit processor (IA-64) or a Sun SPARC processor  
architecture.  
Single port adapter:  
QLogic Corporation  
QLA2460 PCI Fibre Channel ROM BIOS Version X.XX  
Copyright (C) QLogic Corporation 1993-2005 All Rights Reserved.  
Press <Ctrl+Q> for Fast!UTIL  
BIOS for Adapter 0 is disabled  
ROM BIOS not installed  
Dual port adapter:  
QLogic Corporation  
QLA2462 PCI Fibre Channel ROM BIOS Version X.XX  
Copyright (C) QLogic Corporation 1993-2005 All Rights Reserved.  
Press <Ctrl+Q> for Fast!UTIL  
BIOS for Adapter 0 is disabled  
BIOS for Adapter 1 is disabled  
To display the Fibre Channel devices, press Ctrl+Q, and then use the Fast!UTIL  
on page 23 for detailed utility program information.  
If the information displayed is not correct and you have checked the adapter  
configuration, go to Chapter 5, “Troubleshooting,” on page 31 for problem solving  
information.  
If the information displayed is correct, go to Chapter 2, “Installing the FC 4Gbps  
instructions on how to update the FC 4Gbps PCI-X Adapter BIOS code.  
8
IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device  
drivers and updating the BIOS code  
Note: For the latest information about supported operating systems, versions of  
device drivers, utilities, and documentation, go to http://www-1.ibm.com/  
After installing your FC 4Gbps PCI-X Adapter, you must perform one of the  
following two steps.  
1. Install the adapter device driver followed by the QLogic® SANsurfer Pro Utility  
program and update the adapter BIOS code and nonvolatile random access  
memory (NVRAM) using the SANsurfer program.  
or  
2. Update the adapter BIOS code and nonvolatile random access memory  
(NVRAM) via a bootable CD-ROM or diskette, using the flasutil utility program,  
then install the adapter device drivers.  
Note: Step 1 is the recommended method for updating the adapter BIOS and  
NVRAM.  
Installing the FC 4Gbps PCI-X Adapter device drivers  
The device drivers and installation instructions for the following supported operating  
systems are provided on the IBM System Storage DS4000 FC 4Gbps PCI-X Host  
Bus Adapter Support CD:  
v Microsoft® Windows® 2000 and Server 2003  
v Novell® NetWare®  
v Linux®  
For additional instructions, see the README files for the appropriate operating  
systems, which are located in the corresponding operating system directories.  
Note: For the latest information about supported operating systems, versions of  
device drivers, utilities, and documentation, go to http://www-1.ibm.com/  
To update the adapter BIOS code when the adapter is installed in the server with  
an Intel 32-Bit processor (IA-32), an Intel Extended Memory 64-Bit Technology  
(EM64T) processor, or Advanced Micro Devices 64-Bit (AMD-64) architecture only,  
you can use the BIOS Update Utility on the Support CD that comes with the  
adapter; or you can create and use a BIOS Update Utility diskette. When the  
adapter is installed in a server with an Intel 64-Bit processor (IA-64), see the  
README in the PCI-X HBA EFI driver package, for instructions about how to load  
the EFI driver (instead of BIOS code) and update the NVRAM settings of the  
adapter.  
Notes:  
1. The recommended method of updating the BIOS and the adapter NVRAM  
settings is to use the QLogic SANsurfer Pro Utility software.  
2. For the dual port version of the FC 4Gbps PCI-X Adapter, there is only one  
flash BIOS image for both ports; however, each port will have its own NVRAM  
setting.  
© Copyright IBM Corp. 2006  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the QLogic SANsurfer Pro Utility  
The installation files for the QLogic SANsurfer Pro Utility, for Microsoft Windows  
2000 and Server 2003, Novell NetWare, or Linux platforms, can be found in either  
the SANSurfer_FAStT-MSJ folder on the DS4000 Storage Manager host software  
CD or in the downloadable Web package at the DS4000 Technical Support Web  
SANSurfer Pro Utility installation and system requirements  
The SANSurfer Pro Utility installation and system requirements are found in the  
README files that come with the utility program.  
Installing on Windows and Novell NetWare platforms  
Note: If SANSurfer is already installed, uninstall it prior to installing a new copy.  
To perform the SANSurfer Pro Utility installation Windows and Novell NetWare  
platforms, you must execute four steps.  
1. Double-click on the executable installation file, which will have a name similar to  
sansurfer2.0.30b62_windows_install-i.exe, for example; then follow the  
on-screen instructions.  
2. At the Choose Product Featuresscreen, select either option a. or b. of the two  
preconfigured installation sets listed below; or, select Customto define an  
installation set.  
a. ALL GUIs and ALL Agents to install the SANsurfer FC HBA Manager, the  
SANsurfer FC HBA Manager, and SANsurfer Switch Manager GUIs,  
including the FC and iSCSI (Windows, Linux, or Solaris) agents,  
or  
b. SANsurfer FC HBA Manager to install only the SANsurfer FC HBA Manager  
GUI.  
Notes:  
1) To install the Novell NetWare agent, you must select Customand then  
select the SANsurfer FC Windows NT® 4/2000/2003 Agentbox, when  
you are presented with the Choose Product Componentwindow.  
2) Do not select the following installation sets unless they are applicable to  
your configuration. These functions are not supported by the DS4000  
storage subsystem product support.  
v SANsurfer Switch Manager GUI, to install only the SANsurfer Switch  
Manager GUI. This option is for managing QLogic switches only.  
v iSCSI GUI and Agent, to install the SANsurfer iSCSI HBA Manager GUI,  
including the iSCSI (Windows, Linux, or Solaris) agent.  
v SANsurfer iSCSI HBA Manager, to install only the SANsurfer iSCSI HBA  
Manager (GUI, not the iSCSI (Windows, Linux, or Solaris) agent).  
Click Next.″  
3. Choose the Destination Location.(The default is: <Windows system  
drive>:\Program Files\QLogic Corporation\SANsurfer.)  
4. If you are installing the SANSurfer NetWare Agent, the installation will display a  
Choose Destination Locationscreen. Use the Browsebutton to point to the  
\SYSTEM directory on the NetWare SYS volume. The installer will automatically  
save the agent in the appropriate NetWare volume.  
10 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Note: Remember, the drive letter must be mapped to the root of the NetWare  
SYS volume.  
5. When you are prompted to enable the QLogic failover configuration, do not  
enable it. (IBM recommends the use of the RDAC multipath driver as the  
DS4000 LUN failover/failback driver, in a Microsoft Windows environment or the  
Novell NetWare native multipath device driver in a NetWare environment.)  
The following are known limitations.  
v The DS4000 storage products do not support the use of SANSurfer to  
configure failover and failback paths or IO load balancing for the DS4000  
storage subsystem logical drives (LUNs) using the QLogic failover version  
(QLDirect) of the FC HBA device driver in Microsoft Windows environments.  
IBM only supports the use of DS4000 RDAC multipath device driver in  
conjunction with the non-failover version of the QLogic FC HBA device driver.  
v The DS4000 storage products do not support the use of LUN masking or  
HBA configuration wizard/functions; neither do the DS4000 storage products  
support non-Fibre Channel HBA functions, such as QLogic SANSwitch or  
iSCSI HBA functions.  
v The QLogic SANSurfer Pro Utility program (formerly known as IBM FAStT  
MSJ program) must not be left installed on X64 servers with Microsoft  
Windows Server 2003 64-Bit edition, while the servers are running IOs to  
DS4000 storage subsystems. Install the QLogic SANSurfer® Pro Utility  
program if you need to perform FC HBA updates or diagnostics; then,  
uninstall it immediately after you have completed these tasks.  
v There is no 64-Bit version of the QLogic SANSurfer Pro Utility program  
(formerly known as FAStT MSJ) for Windows Server 2003 IA64 or x64  
editions. You must use the 32-Bit version of the QLogic SANSurfer Pro Utility  
program for the Windows Server 2003 64-Bit edition. Uninstall the QLogic  
SANSurfer Pro Utility program when the diagnostics are complete; otherwise,  
the program could cause the server to crash in heavy IO loads.  
Note: For information about other possible program limitations, please see the  
README file.  
If you have questions about installing the QLogic SANsurfer Pro Utility, please see  
the README file, which may have a name, for example, like  
readme_SANsurfer_FAStMSJ_win32_NW.txt.  
Installing on the Linux platform  
Note: If SANSurfer is already installed, uninstall it prior to installing a new copy.  
GUI installation  
To perform the SANSurfer Pro Utility installation on a Linux platform, you must  
execute four steps.  
1. Open a shell (command prompt), and change to the directory that contains the  
installation file, which might for example, be named  
sansurfer2.0.30b62_linux_install-i.bin.  
2. At the prompt, type the command to start the program installation wizard.  
sh ./program_name  
where, program_name is  
sansurfer2.0.30b62_linux_install-i.bin  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. At the Choose Product Featuresscreen, select either option a. or b. of the two  
preconfigured installation sets listed below; or, select Customto define an  
installation set.  
a. ALL GUIs and ALL Agents to install the SANsurfer FC HBA Manager, the  
SANsurfer FC HBA Manager, and SANsurfer Switch Manager GUIs,  
including the FC and iSCSI (Windows, Linux, or Solaris) agents,  
or  
b. SANsurfer FC HBA Manager to install only the SANsurfer FC HBA Manager  
GUI.  
v SANsurfer Switch Manager GUI, to install only the SANsurfer Switch  
Manager GUI. This option is for managing QLogic switches only.  
v iSCSI GUI and Agent, to install the SANsurfer iSCSI HBA Manager GUI,  
including the iSCSI (Windows, Linux, or Solaris) agent.  
v SANsurfer iSCSI HBA Manager, to install only the SANsurfer iSCSI HBA  
Manager (GUI, not the iSCSI (Windows, Linux, or Solaris) agent).  
Note: Do not select the following installation sets unless they are  
applicable to your configuration. These functions are not supported  
by the DS4000 storage subsystem product support.  
– SANsurfer Switch Manager GUI, to install only the SANsurfer  
Switch Manager GUI. This option is for managing QLogic  
switches only.  
– iSCSI GUI and Agent, to install the SANsurfer iSCSI HBA  
Manager GUI, including the iSCSI (Windows, Linux, or Solaris)  
agent.  
– SANsurfer iSCSI HBA Manager, to install only the SANsurfer  
iSCSI HBA Manager (GUI, not the iSCSI (Windows, Linux, or  
Solaris) agent).  
Click Next.″  
4. QLogic SANsurfer installs in the /opt/QLogic_Corporation/SANsurfer directory.  
The launch script is located in the /usr directory. The qlremote is installed in the  
/usr/local/bin directory.  
5. When you are prompted to enable the QLogic failover configuration, do not  
enable it. (IBM recommends the use of the RDAC multipath driver, as the  
DS4000 LUN failover/failback driver, in a Linux environment.)  
The following are known limitations.  
v The DS4000 storage products do not support the use of SANSurfer to  
configure failover and failback paths or IO load balancing for the DS4000  
storage subsystem logical drives (LUNs) using the QLogic failover version  
(QLDirect) of the FC HBA device driver in a Linux environment. IBM only  
supports the use of DS4000 RDAC multipath device driver in conjunction with  
the non-failover version of the QLogic FC HBA device driver.  
v The DS4000 storage products do not support the use of LUN masking or  
HBA configuration wizard/functions: neither do the DS4000 storage products  
support non-Fibre Channel HBA functions, like QLogic SANSwitch or iSCSI  
HBA functions.  
Note: For information about other possible program limitations, please see the  
README file.  
If you want to perform a command-line installation of the QLogic SANsurfer Pro  
Utility, or a command-line installation of only the qlremote agent, or if you have  
12 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
questions about the installation, please see the instructions in the  
readme_SANsurfer_FAStMSJ_Linux_IA32.txt file.  
Using the QLogic SANsurfer Pro Utility  
This section provides an overview of the QLogic SANsurfer Pro Utility program.  
Experienced users can use this program to customize the configuration of the FC  
4Gbps PCI-X Adapter when it is installed in a server.  
QLogic SANsurfer Pro Utility overview  
The SANsurfer Pro Utility program is used to manage the IBM FC 4Gbps and  
2Gbps PCI-X Adapters (FC HBAs) in a storage area network (SAN). It is a  
network-capable application that can connect to and configure FC 4Gbps PCI-X  
Adapters in remote servers, enabling centralized management and configuration of  
an entire SAN containing components and storage devices.  
You can use the SANsurfer Pro Utility program to manage and control one or more  
adapters that are installed on local or remote systems. The SANsurfer Pro Utility  
program is used, along with problem determination procedures (PDPs), on new or  
existing installations to help diagnose Fibre Channel (FC) subsystem problems in  
adapters, controllers, and devices that are attached to the Fibre Channel fabric or  
loop.  
You can also perform the following operations:  
Disable (unconfigure) a device on a host bus adapter  
When a device is set as unconfigured, it is not recognized by the adapter  
and is not accessible to the adapter on that server.  
Enable a device  
This operation adds a device and makes it accessible to the adapter on that  
system.  
Note: The diagnostic functions of the SANsurfer Pro Utility program are available  
for all supported operating systems.  
SANsurfer Pro Utility features  
Use the SANsurfer Pro Utility program to perform the following tasks:  
v Set the SANsurfer Pro Utility program options  
v Connect to hosts for managing FC 4Gbps PCI-X Adapters installed in the hosts  
v Disconnect from a host  
v View detailed event and alarm-log information  
v Use host-to-host SAN configuration policies  
v Configure port devices  
v Use logical unit number (LUN) level configuration  
v Monitor in real time to determine when failovers occur, using the Failover  
Watcher  
v Control host-side agent operations, including setting of the host agent polling  
interval  
v Review host adapter information, including:  
– General information  
– Statistics  
– Information about attached devices  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
– Link status for attached device  
v Perform adapter functions, including:  
– Configuring the adapter NVRAM settings  
– Executing fibre diagnostics (read/write buffer loopback tests)  
– Performing flash updates on an adapter  
– Performing NVRAM updates on an adapter  
v Manage configurations:  
– Save configurations for offline policy checks and SAN integrity  
– Load configurations from a file if the host is offline for policy checks and SAN  
integrity  
v Confirm security  
SANsurfer Pro utilities  
Within the SANsurfer Pro Utility program, there are other utilities that you can use  
to update I/O expansion card firmware and perform adapter-level configurations on  
a host-connected adapter. Please refer to the online help for more information.  
Notes:  
1. Not all features of the SANsurfer program are supported for all supported  
operating systems. Please refer to the operating system-specific README file  
for information about possible program limitations.  
2. If you are prompted for a password, the default password is config.  
the BIOS” section are generally the correct steps needed to update the NVRAM  
BIOS; however, these steps might not be exact, taking into account all of the  
possible program windows that could be displayed in an exact sequence. Also, if  
you are using a newer version of the SANsurfer program, the steps might have a  
different sequence.  
Using SANsurfer Pro Update Option ROM Utility to update the  
BIOS  
Use the Update Option ROM Utility in the SANsurfer Pro Utility program to update  
the adapter BIOS code. The latest version of 4Gbps Fibre Channel Adapter BIOS  
BIOS code file is a binary (.bin) file; for example, q24mfxxx.bin.  
To update the flash BIOS firmware, complete the following steps:  
1. Make sure that the device drivers for the FC 4Gbps PCI-X Single/Dual Port  
HBA (PCI-X) Adapters are installed on the host containing the adapters; if the  
correct device drivers are not installed on the host where the adapters reside,  
the SANsurfer program will not list the FC 4Gbps PCI-X adapters. If the server  
where the SANsurfer program is installed is not the host server containing the  
FC 4Gbps PCI-X Adapters, make sure that the SANsurfer agent is installed on  
the host server and that the host server’s Ethernet port is in the same IP subnet  
as the server where the SANsurfer program is installed.  
2. Double-click the SANsurfer Pro Utility program icon to start the SANsurfer Pro  
Utility application.  
3. When the Connect to Host window is displayed, click Connect,to connect to  
the preferred host.  
4. Next, a configuration wizard window displays, asking you to start the wizard.  
Click No,and the configuration wizard window closes.  
14 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
5. In the SANsurfer FC HBA window, in the FC HBAtab on the left pane, select  
the port under the newly installed FC 4Gbps PCI-X Adapters; the Information″  
tab in the right pane displays all the information about the new adapters.  
6. In the row of tabs at the top of the right pane in the SANsurfer program window,  
click on the Utilitiestab. Then, in the center of the Utilities information pane  
you will find seven buttons: click on the Update Option ROMbutton. This will  
start the BIOS update. Select the appropriate BIOS file and click OK,when  
you are prompted to enter the file name of the new BIOS firmware.  
7. When the BIOS has been updated, the Option ROM Save window displays.  
Click OKto save the changes.  
8. Repeat Steps 5 through 7 to update the BIOS for other FC HBAs in the host  
server. Reboot the server if you have completed the updates; or, proceed to the  
if you want to update the adapter NVRAM.  
Important: Because there is only one BIOS image per adapter, the Update Option  
ROM button will not be enabled when you select the second port of a dual port FC  
4Gbps PCI-X Adapter.  
Using the SANsurfer Pro Update NVRAM Utility to update the  
NVRAM  
Use the Update NVRAM Utility in the SANsurfer Pro Utility program to update the  
adapter NVRAM firmware. The latest version of 4Gbps Fibre Channel Adapter  
NVRAM firmware is available from http://www-1.ibm.com/servers/storage/support/  
disk/. The NVRAM firmware file is a data (.dat) file; for example, nvram200.dat.  
To update the NVRAM firmware, complete the following steps:  
1. Make sure that the device drivers for the FC 4Gbps PCI-X Single/Dual Port  
HBA (PCI-X) Adapters are installed on the host containing the adapters; if the  
correct device drivers are not installed on the host where the adapters reside,  
the SANsurfer program will not list the new adapters. If the server where the  
SANsurfer program is installed is not the host server containing the new  
adapters, make sure that the SANsurfer agent is installed on the host server  
and that the host server’s Ethernet port is in the same IP subnet as the server  
where the SANsurfer program is installed.  
2. Double-click the SANsurfer Pro Utility program icon to start the SANsurfer Pro  
Utility application.  
3. When the Connect to Host window is displayed, click Connect,to connect to  
the preferred host.  
4. A configuration wizard window displays, asking you to start the wizard. Click  
No,and the configuration wizard window closes.  
5. In the SANsurfer FC HBA window, in the FC HBAtab on the left pane, select  
the port under the newly installed FC 4Gbps PCI-X Adapters; the Information″  
tab in the right pane displays all the information about the new adapters.  
6. In the center of the Utilities information pane you will find three buttons: click on  
the Update NVRAMbutton.  
7. You are then prompted to enter the file name for the new NVRAM firmware  
update.  
8. Enter the file name of the NVRAM firmware update. Click OKto complete the  
update, or click Cancelto cancel the update.  
When you click OK,the SANsurfer Pro Utility program verifies the content of the  
new file and updates the firmware. If the firmware update fails, an error message  
displays.  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Important:  
1. Because there are two NVRAM setting areas per dual port FC 4Gbps PCI-X  
Adapter (one NVRAM setting area for each port), you must select each of the  
ports separately and perform the NVRAM update for each port, provided you  
want to update the NVRAM settings on both ports.  
2. Updating the NVRAM firmware resets all of the NVRAM settings to the default.  
After updating the NVRAM firmware, you must reenter all custom configuration  
settings required for your specific operating system.  
Updating the FC 4Gbps PCI-X Adapter BIOS code using the Support  
CD or a BIOS Update Utility diskette  
You can also update the FC 4Gbps PCI-X Adapter BIOS code using the Support  
CD that is shipped with the adapter, or you can create a BIOS Update Utility  
diskette from the Support CD (see the “Creating the FC 4Gbps PCI-X Adapter BIOS  
Whether you want to use the Support CD or the BIOS Update Utility diskette, just  
follow the instructions in the common sections, “Using the flasutil command prompt”  
the common sections will be designated for using either the CD or the diskette and  
will be appropriately labeled CD or Diskette.  
To update the DS4000 FC 4Gbps PCI-X Adapter BIOS code and NVRAM using the  
BIOS Update Utility on the Support CD, choose one of the following methods:  
v flasutil command prompt. Use this method to type in command-line options.  
v flasutil BIOS Update Utility menu. Use this method to select a command-line  
option from the menu.  
Using the flasutil command prompt  
Complete the following steps to update your DS4000 FC 4Gbps PCI-X Adapter  
BIOS code and NVRAM, using the flasutil command prompt.  
1. CD: Insert the IBM System Storage DS4000 FC 4Gbps PCI-X Host Bus  
Adapter Support CD into the CD-ROM drive. Restart the server. Your server  
starts to a DOS prompt.  
Diskette: Insert the BIOS Update Utility diskette that you created into the  
diskette drive and restart the server. Your server starts to a DOS prompt.  
2. To update the BIOS code in the flash utility, do the following:  
From the DOS prompt, type:  
flasutil /i /FB xxxx /o BiosFirmwarefile.bin  
where  
BiosFirmwarefile.bin  
is the name of the BIOS firmware file (if the BIOS firmware file name is  
omitted, flasutil will look for a firmware file named, ql24rom.bin), and xxxx is  
the adapter address. If xxxx is omitted, then the program will attempt to flash  
all of the adapters in the host with this firmware file.  
Press Enter.″  
Caution: If the /FB option is not specified when attempting to flash the FC  
4Gbps PCI-X Adapter BIOS, the BIOS image will not be correctly flashed into  
the adapter’s BIOS area.  
16 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. The flasutil program will display the existing version of the BIOS, the newer  
BIOS version, and a message telling you if the update was successful or  
unsuccessful.  
The following output example resembles the output you might see upon  
execution of the flasutil /i /FB xxxx /o BiosFirmwarefile.bin command,  
where, for this example, 2300 is substituted for xxxx.  
QLogic NOVRAM and FLASH Programming Utility Version 1.55  
Copyright (C) QLogic Corporation 1998-2005. All rights reserved.  
Current version of QLA2462 flash BIOS at I/O Address 2300 is 1.04  
New version of QLA2462 flash BIOS at I/O Address 2300 is 1.09  
Programming QLA2462 flash at I/O Address 2300  
Verifying QLA2462 flash at I/O Address 2300  
Flash at I/O Address 2300 Verified Successfully  
Programming rest of 1 meg flash at I/O Address 2300  
...  
Flash at I/O Address 2300 Programmed Successfully  
C:\  
Note: For the flasutil /i /FB 2400 /o Biosfirmwarefile.bin command,  
where 2400 is the I/O address of the second port of a dual port FC  
4Gbps PCI-X Adapter, there is no update status due to there being only  
one BIOS area per adapter. This BIOS area is referred to via the I/O  
address of the first port of a dual port FC 4Gbps PCI-X Adapter.  
The following output example resembles the output you might see upon  
execution of the flasutil /i /FB 2400 /o Biosfirmwarefile.bin command.  
QLogic NOVRAM and FLASH Programming Utility Version 1.55  
Copyright (C) QLogic Corporation 1998-2005. All rights reserved.  
C:\  
4. To update the NVRAM, do the following:  
From the DOS prompt, type:  
flasutil /i /l xxxx /n NVRAMfile.DAT  
where NVRAMfile.DAT is the name of the NVRAM setting file (there must also  
be a companion file with the same NVRAM file name, having the .def file  
extension, instead of the .dat file extension. If the NVRAM setting file name is  
omitted, flasutil will look for NVRAM files with the following names;  
nvram24.dat and nvram24.def), and xxxx is the adapter address. If xxxx is  
omitted, then the program will attempt to flash all of the adapters in the host  
with this NVRAM file.  
Press Enter.″  
Note: If this is a dual port adapter and the adapter address is specified, you  
need to run this command twice (using both port addresses) to update  
the NVRAM on both ports.  
5. Press Enter.″  
6. The flasutil program will display the existing version of the NVRAM, the newer  
NVRAM version, and a message telling you if the update was successful or  
unsuccessful.  
7. To update the standard NVRAM defaults in the adapter to the new defaults  
from the NVRAM files, do the following:  
At the DOS prompt, type:  
flasutil /i /u xxxx  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
where xxxx is the adapter address. If xxxx is omitted, then the program will  
attempt to change (on all of the adapters in the host) the standard NVRAM  
defaults in the adapter, to the new defaults from the NVRAM files.  
8. Press Enter.″  
9. The flasutil program will display the existing version of the NVRAM, the newer  
NVRAM version, and a message telling you if the update was successful or  
unsuccessful.  
The following output example resembles the output you might see upon  
execution of the flasutil /i /u xxxx /n NVRAMfile.DAT command, where, for  
this example, 2300 is substituted for xxxx.  
QLogic NOVRAM and FLASH Programming Utility Version 1.55  
Copyright (C) QLogic Corporation 1998-2005. All rights reserved.  
Programming QLA2422 NOVRAM at Address 2300  
NOVRAM at Address 2300 Loaded Successfully  
Updating flash at I/O Address 2300  
Verifying flash at I/O Address 2300  
Flash at I/O Address 2300 Verified Successfully  
C:\  
10. To update the FC 4Gbps PCI-X Adapter BIOS version number, type  
vpd /a /u  
and press Enter.″  
Note: IBM does not support any vpd program options, other than /a and /u.  
The following output example resembles the output you might see upon  
execution of the vpd /a /u command.  
Processing all adapters...  
2422 at address 2300 [1077.2422.1077.0134.0]  
Reading vpd from nvram...  
Reading versions from flash...  
Updating vpd in nvram...  
Verifying...  
Verify passed  
2422 at address 2400 [1077.2422.1077.0134.1]  
Reading vpd from nvram...  
Reading versions from flash...  
Updating vpd in nvram...  
Verifying...  
Verify passed  
C:\  
Note: This example shows what would be displayed when there is one  
QLA2462 adapter installed in the server, with port I/O addresses 2300  
and 2400.  
11. To review additional command-line options that you can use, go to  
“Command-line options”; then, continue with Step 12.  
12. CD: Remove the CD from the CD-ROM drive and restart the server.  
Diskette: Remove the diskette from the diskette drive and restart the server.  
Command-line options  
This section describes additional command-line options that you can use. Complete  
the following steps to review these command-line options:  
18 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1. At the DOS prompt, type:  
flasutil /?  
2. Press Enter.″  
The following command-line options display:  
/L xxxx = Write NOVRAM to adapter address xxxx  
If no address specified then write NOVRAM to all adapters  
/F xxxx = Write Flash to adapter, adapter address = xxxx  
/FR xxxx = Write ISP2322/6322 Risc Code to Flash , adapter address = xxxx  
/FB xxxx = Write MultiFlash image to adapter, adapter address = xxxx  
If no address specified then write Flash to all adapters  
/D xxxx = Copy NOVRAM to file: QLxxNVR.SAV, adapter address = xxxx  
/W xxxx = Copy Flash to file: QLxxROM.SAV, adapter address = xxxx  
/U xxxx = Update Bios NOVRAM defaults, adapter address = xxxx  
If no address specified then Update all adapters  
/N <filename.ext> = Use <filename.ext> instead of NVRMxx.DAT  
/O <filename.ext> = Use <filename.ext> instead of QLxxROM.BIN  
/I  
/M  
/Q  
= Ignore Subsystem ID  
= Program all adapters  
= Quiet Mode, no messages will be displayed  
/S xxxx = Display serial number of adapter at address xxxx  
If no address specified then display serial number of all adapters  
/V xxxx = Display current version number of BIOS on adapters at address xxxx  
If no address specified then display BIOS version of all adapters  
/C xxxx = Verify Flash of adapter at address xxxx  
If no address specified then verify Flash of all adapters  
/X xxxx = Verify NOVRAM of adapter at address xxxx  
If no address specified then verify NOVRAM of all adapters  
/Y xxxx = Display Port Name of adapter at address xxxx  
If no address specified then display Port Name of all adapters  
Notes:  
1. All of the options listed are supported and you can run them from the  
command-line. Options /L, /D, /U, /N, /T, and /X might not display.  
2. Caution: Do not use the /F or /FR options to update the FC 4Gbps PCI-X  
Adapter BIOS (Flash). The /F option is used for updating the BIOS of the IBM  
FC2 or FC2-133 2 Gb Host Bus Adapters, only.  
The following list describes examples of additional command-line options that you  
can use.  
v To write NVRAM to all FC 4Gbps PCI-X Adapters in a system, without being  
prompted for an I/O address, type:  
flasutil /L  
Press Enter.″  
v To save the existing flash code of the adapter at I/O address F600 to file  
ql24rom.sav, type:  
flasutil /W F600  
Press Enter.″  
v To write NVRAM to the adapter at I/O address f400, type:  
flasutil /L f400  
Press Enter.″  
v To write NVRAM and flash an adapter at I/O address f800, type:  
flasutil /L f800 /FB f800  
Press Enter.″  
v To write NVRAM and flash all adapters, type:  
flasutil /L /FB  
Press Enter.″  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
v To update BIOS NVRAM defaults, type:  
flasutil /U  
Press Enter.″  
v To verify NVRAM in all adapters, type:  
flasutil /X  
Press Enter.″  
Using the flasutil BIOS Update Utility menu  
Complete the following steps to update the DS4000 FC 4Gbps PCI-X Adapter BIOS  
code, using the flasutil BIOS Update Utility menu:  
1. CD: Insert the IBM System Storage DS4000 FC 4Gbps PCI-X Host Bus  
Adapter Support CD into the CD-ROM drive. Restart the server. Your server  
starts to a DOS prompt.  
Diskette: Insert the BIOS Update Utility diskette into the diskette drive and  
restart the server. Your server starts to a DOS prompt.  
2. From the DOS prompt, type:  
flasutil  
3. Press Enter.″  
4. If you have only one adapter installed, go to Step 5. If you have more than one  
adapter installed, a list of adapters and I/O addresses displays. At the  
command prompt, type the appropriate I/O address and press Enter.″  
5. The following option menu displays.  
F = Write Flash  
FB = Write MultiFlash image  
W = Copy Flash to file: QLxxROM.SAV  
S = Display serial number  
V = Display current BIOS version  
C = Verify Flash  
Y = Display port name  
L = Write NVRAM  
A = Write NVRAM and defaults  
D = Copy NVRAM to file: QLxxNVRM.SAV  
U = Update BIOS NVRAM defaults  
X = Verify NVRAM  
Notes:  
a. All of the listed options are supported and can be run from the  
command-line. Options L, A, D, U, and X might not display.  
b. Caution: Do not use the F or FR options to update the FC 4Gbps PCI-X  
Adapter BIOS (Flash). The /F option is used for updating the BIOS of the  
IBM FC2 or FC2-133 2 Gb Host Bus Adapters, only.  
c. Each adapter can be configured with more than one option.  
d. Because there is only one BIOS (Flash) area in a dual port FC 4Gbps  
PCI-X Adapter, entering option FB for the second port I/O address of a  
dual port adapter, will result in command completion with no BIOS status  
message displayed.  
6. Type the letter for the option you want and press Enter.″  
7. If you have additional adapters installed, or if you want to configure your  
adapter with more than one option, continue with Step 8; otherwise, go to Step  
20 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
8. Repeat Steps 2 through 6 for each additional adapter or if you want to  
configure your adapter with more than one option.  
9. CD: Remove the CD from the CD-ROM drive and restart the server.  
Diskette: Remove the diskette from the disk drive, and restart the server.  
Creating the FC 4Gbps PCI-X Adapter BIOS Update Utility diskette  
If you cannot use the Support CD to update the adapter BIOS code, you can create  
a diskette using the Support CD. Instructions for creating and using the diskette are  
described in the following sections.  
Note: For a Novell NetWare environment, you will need to unpack the BIOS  
Update Utility diskette using a server that is running a Microsoft® Windows®  
2000 or Linux® operating system.  
Creating the diskette  
Create the BIOS Update Utility diskette by copying the image you need from the  
IBM System Storage DS4000 PCI-X Host Bus Adapter Support CD or by  
Web site.  
For Microsoft Windows 2000 or Server 2003  
Complete the following steps to create a BIOS Update Utility diskette for Microsoft®  
Windows® 2000 or Server 2003 from the IBM System Storage DS4000 FC 4Gbps  
PCI-X Host Bus Adapter Support CD:  
1. Insert the IBM System Storage DS4000 PCI-X Host Bus Adapter Support CD  
into the CD-ROM drive.  
2. Insert a diskette into the diskette drive.  
3. At the command prompt, type:  
d:\tools\dsk4w32 d:\images\biosnvrm\24xx\246x_xxx.img a:  
Where d is the CD-ROM drive and a is the diskette drive.  
4. Press Enter.″  
5. Remove the IBM System Storage DS4000 PCI-X Host Bus Adapter Support CD  
from the CD-ROM drive.  
6. Remove the diskette from the diskette drive and label the diskette appropriately.  
For Linux  
Complete the following steps to create a BIOS Update Utility diskette for Linux from  
the IBM System Storage DS4000 PCI-X Host Bus Adapter Support CD:  
1. Insert the IBM System Storage DS4000 PCI-X Host Bus Adapter Support CD  
into the CD-ROM drive and restart the server.  
2. Insert a diskette into the diskette drive.  
3. At the command prompt, type:  
mount -t iso9660/dev/cdromdevicefile /mnt  
Where cdromdevicefile is the specific device file for the CD-ROM block device.  
4. Press Enter.″  
5. Type:  
dd if=/mnt/images/biosnvrm/24xx/246x_xxx.img of=/dev/diskettedevicefile bs=32  
6. Press Enter.″  
7. Unmount the CD-ROM by typing:  
Chapter 2. Installing the FC 4Gbps PCI-X Adapter device drivers and updating the BIOS code 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
unmount /mnt  
8. Remove the IBM System Storage DS4000 PCI-X Host Bus Adapter Support  
CD from the CD-ROM drive.  
9. Remove the diskette from the diskette drive and label the diskette  
appropriately.  
10. To update the DS4000 FC 4Gbps PCI-X Adapter BIOS code and NVRAM  
using the BIOS Update Utility from the diskette, choose one of the following  
methods:  
v flasutil command prompt. Use this method to type in command-line options.  
v flasutil BIOS Update Utility menu. Use this method to select a command-line  
option from the menu.  
22 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3. Configuring the FC 4Gbps PCI-X Adapter with  
Fast!UTIL  
This chapter provides detailed configuration information for advanced users who  
want to customize the configuration of the FC 4Gbps PCI-X Adapter and the  
connected fibre-channel devices. You can configure the adapter using the Fast!UTIL  
utility.  
Starting Fast!UTIL  
Important: If the configuration settings are incorrect, the FC 4Gbps PCI-X Adapter  
will not function properly. Do not modify the default configuration settings unless you  
are instructed to do so by an IBM technical support representative or by the  
installation instructions. The default NVRAM settings, which were loaded in the  
adapter at the factory, are for a typical Microsoft Windows installation. See the FC  
4Gbps PCI-X Adapter device driver README file for the appropriate operating  
system to determine the required NVRAM setting modifications for that operating  
system.  
Note: The recommended way to update the BIOS and the adapter NVRAM  
settings is to use the QLogic SANsurfer Pro Management Suite Java™  
software, which can be downloaded from the following Web site:  
When the adapter is installed in the server with an Intel 32-Bit processor (IA-32), an  
Intel Extended Memory 64-Bit Technology (EM64T) processor, or an Advanced  
Micro Devices 64-Bit (AMD-64) architecture only, you can access Fast!UTIL by  
pressing Ctrl+Q during the BIOS initialization; it might take a few seconds for the  
Fast!UTIL menu to display. Fast!UTIL prompts you to select the adapter that you  
want to configure. After you change the settings that are described in “Host bus  
adapter settings” on page 24, Fast!UTIL restarts the system to enable the new  
parameters. When the adapter is installed in a server with an Intel 64-Bit processor  
(IA-64), see the README in the DS4000 FC 4Gbps PCI-X HBA EFI driver package,  
for instructions about how to modify the NVRAM adapter settings, or use the  
QLogic SANsurfer Pro Management Suite Java software to modify the NVRAM  
settings.  
Accessing HBA settings through Fast!UTIL  
The Fast!UTIL feature provides access to host bus adapter settings. To access this  
feature, simultaneously press and hold the ALT + Q keys or the Ctrl + Q keys  
during BIOS initialization. It may take a few seconds for the Fast!UTIL menu to  
appear. If more than one board is installed, Fast!UTIL prompts you to select a board  
to configure. After you change adapter settings, Fast!UTIL reboots your system to  
load the new parameters. Upon entering Fast!UTIL, the following selections are  
available on the Fast!UTIL Options menu:  
v Configuration Settings  
v Scan Fibre Devices  
v Fibre Disk Utility  
v Loopback Test  
v Select Host FC 4Gbps PCI-X Adapter  
© Copyright IBM Corp. 2006  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
v Exit FASt!UTIL  
You can access the host bus adapter settings through the Configuration Settings  
PCI-X Adapter Settings” on page 25 for detailed information on the settings.  
Host bus adapter settings  
You can modify most of the host bus adapter settings. The current default settings  
for the host bus adapter are listed in “Advanced FC 4Gbps PCI-X Adapter Settings”  
on page 25. These settings are described following the table. You can modify the  
following default host bus adapter settings.  
BIOS address  
The BIOS address is the I/O address where the BIOS code is stored when  
you press Ctrl+Q or when you have the BIOS code enabled for starting  
from the root directory. This is the address of the BIOS code in ROM  
shadow memory. Multiple adapters can be installed in the server, but only  
one BIOS instance is loaded for all of the adapters.  
Note: The BIOS code is loaded from the first port of the first adapter that  
the server recognizes. This code is used for all remaining DS4000  
FC 4Gbps PCI-X Single Port and DS4000 FC 4Gbps PCI-X Dual  
Port adapters in the same bus or server. The level of BIOS code that  
is loaded does not affect other adapters with earlier BIOS code  
levels.  
Revision  
The BIOS revision is the revision number of the BIOS code that is loaded  
from the first FC 4Gbps PCI-X Adapter that the server recognizes. Each FC  
4Gbps PCI-X Adapter in the server has the same BIOS code revision  
number because only one BIOS code instance is loaded.  
FC 4Gbps PCI-X Adapter serial number  
The adapter serial number is located on the noncomponent side of the  
adapter. See Figure 1 on page 3 for the location of the serial number label.  
Interrupt level  
The interrupt level is the interrupt that is used by the FC 4Gbps PCI-X  
Adapter. The interrupt level can change when the operating system is  
installed.  
FC 4Gbps PCI-X Adapter port name  
This is the worldwide port name.  
Host adapter BIOS  
When this setting is Disabled, the ROM BIOS on the FC 4Gbps PCI-X HBA  
is Disabled, freeing space in upper memory. This setting must be Enabled if  
you are booting from fibre channel disk drive attached to the PCI-X board.  
The default is Disabled.  
Frame size  
This setting specifies the maximum frame length supported by the FC  
4Gbps PCI-X HBA. The default size is 2048, which provides maximum  
performance for F-Port (point-to-point) connections.  
Loop reset delay  
After resetting the loop, the firmware refrains from initiating any loop activity  
for the number of seconds specified in this setting. The default is 5  
seconds.  
24 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
FC 4Gbps PCI-X Adapter hard loop ID  
This setting forces the adapter to attempt to use the ID specified in the  
Hard Loop ID setting. The default is Disabled.  
Hard loop ID  
If the FC 4Gbps PCI-X Adapter Hard Loop ID setting is Enabled, the  
adapter attempts to use the ID specified in this setting. The default ID is 0.  
You should set this ID to a unique value from 0-125 if there is more than  
one adapter connected to a FC-AL loop, and the FC 4Gbps PCI-X Adapter  
Hard Loop ID setting is Enabled.  
Spin up delay  
When this bit is set, the BIOS will wait up to 5 minutes to find the first drive.  
The default setting is Disabled.  
Connection Options  
This setting defines the type of connection (loop or point to point) or  
connection preference. The default is 2.  
Fibre Channel Tape Support  
This setting enables FCP-2 recovery. The default is Disabled. You should  
change this setting to Disabled if the HBA is connected to a DS4000  
storage server. The DS4000 storage server does not support a tape device  
through the same Fibre-Channel HBA from the host server.  
Data Rate  
This setting determines the data rate. When this setting is 0, the FC 4Gbps  
PCI-X HBA runs at 1Gbps. When this setting is 1, the FC 4Gbps PCI-X  
HBA runs at 2Gbps. When this setting is 2, Fast!UTIL determines what rate  
your system can accommodate and sets the rate accordingly. The default is  
2 (auto-configure). When the setting is 3, the FC 4Gbps PCI-X HBA runs at  
4Gbps.  
Table 4. FC 4Gbps PCI-X HBA data rates  
Bits 15–13 (h)  
Data rate  
0
1 gigabit/second  
2 gigabits/second  
Auto-negotiated  
4 gigabits/second  
Reserved  
1
2
3
4–7  
Advanced FC 4Gbps PCI-X Adapter Settings  
Access the following advanced host bus adapter settings through the Configuration  
Settings menu in Fast!UTIL and select Advanced FC 4Gbps PCI-X Adapter  
Settings. The default settings for the FC 4Gbps PCI-X HBA are as follows:  
Execution Throttle  
This setting specifies the maximum number of commands executing on any  
one port. When the execution throttle of a port is reached, no new  
commands are executed until the current command finishes executing. The  
valid options for this setting are 1-256. The default is 256.  
LUNs per Target  
This setting specifies the number of LUNs per target. Multiple LUN support  
is typically for redundant array of independent disks (RAID) servers that use  
LUNs to map drives. The default is 256.  
Chapter 3. Configuring the FC 4Gbps PCI-X Adapter with Fast!UTIL 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Enable LIP Reset  
This setting determines the type of loop initialization process (LIP) reset that  
is used when the operating system initiates a bus reset routine. When this  
setting is Yes, the driver initiates a global LIP reset to clear the target  
device reservations. When this setting is No, the driver initiates a global LIP  
reset with full login. The default is No.  
Enable LIP Full Login  
This setting instructs the ISP chip to log in again to all ports after any LIP.  
The default is Yes.  
Enable Target Reset  
This setting enables the drivers to issue a Target Reset command to all  
devices on the loop when a SCSI Bus Reset command is issued. The  
default is Yes.  
Login Retry Count  
This setting specifies the number of times the software tries to log in to a  
device. The default is 30 retries for Microsoft Windows Operating System  
environment. Please review the device driver README for the correct  
setting in other operating system environments.  
Port Down Retry Count  
This setting specifies the number of seconds that the software waits before  
it retries a command to a port returning port down status. The default is 30  
seconds. In a DS4000 storage server configuration with the maximum  
number of drive expansion enclosures or in MCSC configurations, you  
should increase this setting to 70.  
Link Down Timeout  
This setting specifies the number of seconds the software that the software  
waits for a link down to come up. The default is 30 seconds.  
Extended Error Logging  
This setting provides additional error and debug information to the operating  
system. When enabled, events are logged into the Windows Event Viewer.  
The default is Disabled.  
Operation Mode  
This setting specifies the reduced interrupt operation (RIO) modes, if  
supported by the software driver. RIO modes allow posting multiple  
command completions in a single interrupt. The default is 0.  
Interrupt Delay Timer  
This setting contains the value (in 100-microsecond increments) that is  
used by a timer to set the wait time between accessing (DMA) a set of  
handles and generating an interrupt. The default is 0.  
Selectable boot settings  
When you set the Selectable Boot Settings option to Enabled, you can select the  
worldwide port name of the fibre-channel hard disk from which you want to start up  
(boot). When this option is set to Enabled, the node starts from the selected  
fibre-channel hard disk, ignoring any IDE or SCSI hard disks that are attached to  
your server. When this option is set to Disabled, the Boot ID and Boot LUN  
parameters have no effect.  
The BIOS code in some new systems supports selectable start up, which  
supersedes the Fast!UTIL selectable start up setting. To start from a fibre-channel  
26 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
hard disk that is attached to the DS4000 FC 4Gbps PCI-X, select the attached  
fibre-channel hard disk from the system BIOS menu.  
Note: The Selectable Boot Settings option for the DS4000 FC 4Gbps PCI-X  
applies to only fibre-channel hard disk drives.  
Restore default settings  
You can use the Restore Default Settings option to restore the DS4000 FC 4Gbps  
PCI-X default settings and NVRAM.  
The default NVRAM settings are the adapter settings that were saved the last time  
an NVRAM update operation was run from the BIOS Update Utility program (option  
U or command line /U switch). If the BIOS Update Utility program has not been  
used to update the default NVRAM settings since the adapter was installed, the  
factory settings are loaded.  
Note: After selecting Restore default settings, check the NVRAM settings (for  
example the host bus adapter and advanced adapter settings) against the  
values that are recommended in this document and in the device driver  
READMEs for the appropriate operating system.  
Raw NVRAM data  
You can use the Raw NVRAM Data option to display the adapter NVRAM contents  
in hexadecimal format. This is a troubleshooting tool. You cannot modify the data.  
Scan fibre-channel devices  
You can use the Scan Fibre Channel Devices option to scan the fibre-channel loop  
and list all the connected devices by loop ID. Information about each device is  
listed, for example, vendor name, product name, and revision. This information is  
useful when you are configuring your DS4000 FC 4Gbps PCI-X and attached  
devices.  
Fibre-channel disk utility  
Attention: When you perform a low-level format, it removes all data on the disk.  
You can use the Fibre Channel Disk Utility option to scan the fiber-channel loop bus  
and list all the connected devices by loop ID. You can select a disk device and  
perform a low-level format or verify the disk media or data.  
Loopback data test  
You can use the Loopback Data Test option to verify the basic transmit and receive  
functions of the adapter. A fiber-channel loopback connector option must be  
installed into the optical interface connector on the DS4000 FC 4Gbps PCI-X before  
starting the test.  
Select host adapter  
You can use the Select Host PCI-X Adapter option to select, configure, or view a  
specific adapter if you have multiple adapters in your system.  
Chapter 3. Configuring the FC 4Gbps PCI-X Adapter with Fast!UTIL 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ExitFast!UTIL  
After you complete the configuration, use the ExitFast!UTIL option to exit the menu  
and restart the system.  
28 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4. FC 4Gbps PCI-X Adapter operating environment  
and specifications  
This chapter contains the DS4000 FC 4Gbps PCI-X Adapter operating environment  
and specification information.  
Table 5. FC 4Gbps PCI-X Adapter operating environment  
Environment  
Minimum  
10° C (50° F)  
-20° C (-4° F)  
8%  
Maximum  
35° C (95° F)  
70° C (158° F)  
80%  
Operating temperature  
Storage temperature  
Relative humidity (noncondensing)  
Storage humidity (noncondensing)  
5%  
95%  
Table 6. FC 4Gbps PCI-X Adapter specifications  
Type  
Specification  
Host bus  
Conforms to PCI Local Bus Specification, revision 2.3 and  
3.0, PCI-X Protocol Addendum to the PCI Local Bus  
Specification, revision 2.0a, PCI-X Electrical and Mechanical  
Addendum (revision 2.0a) to the PCI Local Bus  
Specification, PCI Bus Power Management Interface  
Specification revision 1.1, PCI Hot Plug Specification,  
revision 1.0  
PCI/PCI-X signaling  
environment  
3.3V (mode 1) and 1.5V (mode 2) buses supported  
PCI/PCI-X transfer rate  
v Support for 32-Bit and 64-Bit PCI bus at 33 MHz and 64  
MHz  
v Support for 64-Bit PCI-X bus at 50 MHz, 100 MHz, and  
133 MHz  
v Support for 64-Bit PCI-X 2.0 bus at 266 MHz  
v Support for dual address bus cycles  
Fibre Channel specifications  
v Fiber-optic media (shortwave multimode 50 micron cable)  
v Bus transfer rate: 400MB per second maximum at  
half-duplex and 800MB per second maximum at  
full-duplex  
v Interface chip: ISP2422 (PCI-X QLA24xx boards)  
v Support for both FCP-SCSI and IP protocols  
v Support for point-to-point fabric connection: F-Port Fabric  
Login  
v Support for FCAL public loop profile: FL-Port Login  
v Support for Fibre Channel services class 2 and 3  
v Support for FCP SCSI initiator and target operation  
v Support for full-duplex operation  
Processor  
Single-chip design that includes a RISC processor, Fibre  
Channel protocol manager, PCI or PCI-X DMA controller,  
and integrated serializer/deserializer (SERDES) and  
electrical transceivers that can auto-negotiate a data rate of  
4 GB per second  
Host data transfer  
64-Bit, bus-master DMA data transfers to 2112 MB per  
second  
© Copyright IBM Corp. 2006  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 6. FC 4Gbps PCI-X Adapter specifications (continued)  
Type  
Specification  
RAM  
RAM 1 M of SRAM supporting parity protection  
BIOS ROM 1 M of flash ROM, field programmable  
NVRAM 2 KB, field programmable  
BIOS ROM  
NVRAM  
Connectors (external)  
v LC-style connector that supports non-OFC, multimode  
fiber-optic cabling using a small form factor (SFF)  
fiber-optic transceiver module  
v Total cable length cannot exceed 500 meters when  
operating at 1Gbps and 300 meters when operating at  
2Gbps  
Form factor  
6.94 cm x 16.75 cm (2.731 in. x 6.60 in.)  
Less than 15 watts  
Operating power  
30 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5. Troubleshooting  
The following four types of installation problems might cause your DS4000 FC  
4Gbps PCI-X Adapter to function incorrectly:  
v Hardware problems  
v Software problems  
v System configuration problems  
v Fibre Channel problems  
If you are having problems, use the following information to help you determine the  
cause of the problem and the action to take.  
Note: Additional troubleshooting and debugging procedures are available in the  
IBM System Storage DS4000 Hardware Maintenance Manual and IBM  
System Storage DS4000 Problem Determination Guide at  
Hardware problems  
To determine if your installation problem is caused by the hardware, perform the  
following tasks:  
v Verify that all cables are attached securely to the correct connectors. Be sure  
that one end of the LC-LC Fibre Channel cable is attached to the optical  
interface connector (located at J1 on the adapter) and that the other end is  
connected to the Fibre Channel device.  
v Verify that the FC 4Gbps PCI-X Adapter is installed correctly and is fully seated  
in the expansion slot. Check for interference due to nonstandard PCI connectors.  
v Verify that the Fast!UTIL data-rate setting is correct. The Fast!UTIL data-rate  
setting must match the speed of the device to which you are connected. See  
v Verify that all peripheral devices are turned on. See “Fibre Channel problems” on  
page 32 for information about displaying attached Fibre Channel devices.  
v Verify that the adapter is ServerProvenfor the server model in which the  
adapter is installed. Verify that the latest BIOS is installed in the server.  
Software problems  
To determine if your installation problem is caused by the software, perform the  
following tasks:  
v Verify that the correct device driver is installed.  
v Verify that your adapter is at the correct BIOS version.  
v Verify that you have the correct adapter NVRAM settings for your Storage Area  
Network (SAN) and operating system.  
System configuration problems  
To determine if your installation problem is caused by the system configuration,  
check your server to ensure that it is configured properly. For more information, see  
© Copyright IBM Corp. 2006  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Note: All PCI-compliant and PCI-X-compliant systems automatically detect 32-Bit  
or 64-Bit adapters and set the appropriate bus speed (for example, 66 MHz  
or 133 MHz).  
If you still have a system configuration problem, refer to the documentation that  
comes with your server, or contact your IBM technical-support representative to  
determine if your system board requires special configuration.  
Fibre Channel problems  
To determine if your installation problem is caused by an attached Fibre Channel  
device, perform the following tasks:  
v Verify that all of the Fibre Channel devices were turned on before you turned on  
the server.  
v Ensure that all cables are connected properly.  
v Verify that you configured your RAID storage subsystems using the utilities  
provided by the manufacturer.  
v If your Fibre Channel switch supports zoning, make sure that your peripheral  
device is configured to the same switch zone as the FC 4Gbps PCI-X Adapter.  
For more information, refer to your Fibre Channel switch documentation.  
In certain cases where the target device may not be able to auto-negotiate the  
Fibre-channel data rate properly, make sure that data rate setting on the FC 4Gbps  
PCI-X HBA matches the target device. For example, if the target device is operating  
at 2Gbps, set the FC 4Gbps PCI-X HBA data rate to 2Gbps.  
32 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A. Accessibility  
This section provides information about alternate keyboard navigation, which is a  
DS4000 Storage Manager accessibility feature. Accessibility features help a user  
who has a physical disability, such as restricted mobility or limited vision, to use  
software products successfully.  
By using the alternate keyboard operations that are described in this section, you  
can use keys or key combinations to perform Storage Manager tasks and initiate  
many menu actions that can also be done with a mouse.  
Note: In addition to the keyboard operations that are described in this section, the  
DS4000 Storage Manager 9.14 software installation package for Windows includes  
a screen reader software interface. To enable the screen reader, select Custom  
Installation when using the installation wizard to install Storage Manager 9.14 on a  
Windows host/management station. Then, in the Select Product Features window,  
select Java Access Bridge in addition to the other required host software  
components.  
Table 7 defines the keyboard operations that enable you to navigate, select, or  
activate user interface components. The following terms are used in the table:  
v Navigate means to move the input focus from one user interface component to  
another.  
v Select means to choose one or more components, typically for a subsequent  
action.  
v Activate means to carry out the action of a particular component.  
Note: In general, navigation between components requires the following keys:  
v Tab - Moves keyboard focus to the next component or to the first member  
of the next group of components  
v Shift-Tab - Moves keyboard focus to the previous component or to the  
first component in the previous group of components  
v Arrow keys - Move keyboard focus within the individual components of a  
group of components  
Table 7. DS4000 Storage Manager alternate keyboard operations  
Short cut  
F1  
Action  
Open the Help.  
F10  
Move keyboard focus to main menu bar and post first  
menu; use the arrow keys to navigate through the  
available options.  
Alt+F4  
Alt+F6  
Close the management window.  
Move keyboard focus between dialogs (non-modal) and  
between management windows.  
© Copyright IBM Corp. 2006  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 7. DS4000 Storage Manager alternate keyboard operations (continued)  
Short cut  
Action  
Alt+ underlined letter  
Access menu items, buttons, and other interface  
components by using the keys associated with the  
underlined letters.  
For the menu options, select the Alt + underlined letter  
combination to access a main menu, and then select the  
underlined letter to access the individual menu item.  
For other interface components, use the Alt + underlined  
letter combination.  
Ctrl+F1  
Display or conceal a tool tip when keyboard focus is on  
the toolbar.  
Spacebar  
Select an item or activate a hyperlink.  
Ctrl+Spacebar  
Select multiple drives in the Physical View.  
(Contiguous/Non-contiguous)  
AMW Logical/Physical View  
To select multiple drives, select one drive by pressing  
Spacebar, and then press Tab to switch focus to the next  
drive you want to select; press Ctrl+Spacebar to select  
the drive.  
If you press Spacebar alone when multiple drives are  
selected then all selections are removed.  
Use the Ctrl+Spacebar combination to deselect a drive  
when multiple drives are selected.  
This behavior is the same for contiguous and  
non-contiguous selection of drives.  
End, Page Down  
Esc  
Move keyboard focus to the last item in the list.  
Close the current dialog (does not require keyboard  
focus).  
Home, Page Up  
Shift+Tab  
Move keyboard focus to the first item in the list.  
Move keyboard focus through components in the reverse  
direction.  
Ctrl+Tab  
Tab  
Move keyboard focus from a table to the next user  
interface component.  
Navigate keyboard focus between components or select  
a hyperlink.  
Down arrow  
Left arrow  
Right arrow  
Up arrow  
Move keyboard focus down one item in the list.  
Move keyboard focus to the left.  
Move keyboard focus to the right.  
Move keyboard focus up one item in the list.  
34 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B. Notices  
This publication was developed for products and services offered in the U.S.A.  
IBM may not offer the products, services, or features discussed in this document in  
other countries. Consult your local IBM representative for information on the  
products and services currently available in your area. Any reference to an IBM  
product, program, or service is not intended to state or imply that only that IBM  
product, program, or service may be used. Any functionally equivalent product,  
program, or service that does not infringe any IBM intellectual property right may be  
used instead. However, it is the user’s responsibility to evaluate and verify the  
operation of any non-IBM product, program, or service.  
IBM may have patents or pending patent applications covering subject matter  
described in this document. The furnishing of this document does not give you any  
license to these patents. You can send license inquiries, in writing, to:  
IBM Director of Licensing  
IBM Corporation  
North Castle Drive  
Armonk, NY 10504-1785  
U.S.A.  
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS  
PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS  
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES  
OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A  
PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or  
implied warranties in certain transactions, therefore, this statement may not apply to  
you.  
This information could include technical inaccuracies or typographical errors.  
Changes are periodically made to the information herein; these changes will be  
incorporated in new editions of the publication. IBM may make improvements and/or  
changes in the product(s) and/or the program(s) described in this publication at any  
time without notice.  
Any references in this publication to non-IBM Web sites are provided for  
convenience only and do not in any manner serve as an endorsement of those  
Web sites. The materials at those Web sites are not part of the materials for this  
IBM product, and use of those Web sites is at your own risk.  
IBM may use or distribute any of the information you supply in any way it believes  
appropriate without incurring any obligation to you.  
Edition notice  
© COPYRIGHT INTERNATIONAL BUSINESS MACHINES CORPORATION, 2006.  
All rights reserved.  
Note to U.S. Government Users — Documentation related to restricted rights —  
Use, duplication or disclosure is subject to restrictions set forth in GSA ADP  
Schedule Contract with IBM Corp.  
© Copyright IBM Corp. 2006  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Trademarks  
The following terms are trademarks of International Business Machines Corporation  
in the United States, other countries, or both:  
IBM  
xSeries  
e-business logo  
IntelliStation  
Netfinity®  
QLogic®  
ServerProven®  
System Storage  
Update Connector™  
SANsurfer®  
Novell®  
NetWare®  
Intel, Celeron, MMX, LANDesk, Pentium®, Pentium II Xeon, Pentium III Xeon, and  
Xeon are trademarks of Intel Corporation in the United States, other countries, or  
both.  
Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation in  
the United States, other countries, or both.  
Java and all Java-based trademarks and logos are trademarks or registered  
trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.  
Linux is a registered trademark of Linus Torvalds.  
QLogic and SANsurfer are registered trademarks of QLogic Corporation.  
Novell and NetWare are registered trademarks of Novell Inc.  
Other company, product, or service names may be the trademarks or service marks  
of others.  
Important notes  
Processor speeds indicate the internal clock speed of the microprocessor; other  
factors also affect application performance.  
CD-ROM drive speeds list the variable read rate. Actual speeds vary and are often  
less than the maximum possible.  
When referring to processor storage, real and virtual storage, or channel volume,  
KB stands for approximately 1024 bytes, MB stands for approximately 1 000 000  
bytes, and GB stands for approximately 1 000 000 000 bytes.  
When referring to hard disk drive capacity or communications volume, MB stands  
for 1 000 000 bytes, and GB stands for 1 000 000 000 bytes. Total user-accessible  
capacity may vary depending on operating environments.  
Maximum internal hard disk drive capacities assume the replacement of any  
standard hard disk drives and population of all hard disk drive bays with the largest  
currently supported drives available from IBM.  
Maximum memory may require replacement of the standard memory with an  
optional memory module.  
36 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IBM makes no representation or warranties regarding non-IBM products and  
services that are ServerProven®, including but not limited to the implied warranties  
of merchantability and fitness for a particular purpose. These products are offered  
and warranted solely by third parties.  
IBM makes no representations or warranties with respect to non-IBM products.  
Support (if any) for the non-IBM products is provided by the third party, not IBM.  
Some software may differ from its retail version (if available), and may not include  
user manuals or all program functionality.  
Electronic emission notices  
Class A statements  
This device has been tested to the FCC limits and found compliant to the Class A  
limits when installed in a host system found compliant to the Class A limits.  
Federal Communications Commission (FCC) statement  
Note: This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment generates,  
uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to cause  
harmful interference, in which case the user will be required to correct the  
interference at his own expense.  
Properly shielded and grounded cables and connectors must be used in order to  
meet FCC emission limits. Properly shielded and grounded cables and connectors  
must be used in order to meet FCC emission limits. IBM is not responsible for any  
radio or television interference caused by using other than recommended cables  
and connectors or by using other than recommended cables and connectors or by  
unauthorized changes or modifications to this equipment. Unauthorized changes or  
modifications could void the user’s authority to operate the equipment.  
This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions: (1) this device may not cause harmful interference, and (2)  
this device must accept any interference received, including interference that may  
cause undesired operation.  
Industry Canada Class A emission compliance statement  
This Class A digital apparatus complies with Canadian ICES-003.  
Avis de conformité à la réglementation d’Industrie Canada  
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du  
Canada.  
Australia and New Zealand Class A statement  
Attention: This is a Class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take adequate  
measures.  
United Kingdom telecommunications safety requirement  
Notice to Customers  
Appendix B. Notices 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
This apparatus is approved under approval number NS/G/1234/J/100003 for indirect  
connection to public telecommunication systems in the United Kingdom.  
European Union EMC Directive conformance statement  
This product is in conformity with the protection requirements of EU Council  
Directive 89/336/EEC on the approximation of the laws of the Member States  
relating to electromagnetic compatibility. IBM cannot accept responsibility for any  
failure to satisfy the protection requirements resulting from a nonrecommended  
modification of the product, including the fitting of non-IBM option cards.  
This product has been tested and found to comply with the limits for Class A  
Information Technology Equipment according to CISPR 22/European Standard EN  
55022. The limits for Class A equipment were derived for commercial and industrial  
environments to provide reasonable protection against interference with licensed  
communication equipment.  
Warning: This is a Class A product. In a domestic environment this product may  
cause radio interference in which case the user may be required to take adequate  
measures.  
Taiwanese Class A warning statement  
Japanese Voluntary Control Council for Interference (VCCI)  
statement  
Chinese Class A warning statement  
38 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix C. European Directive About Product Recycling and  
Disposal  
This unit must be recycled or discarded according to applicable local and national  
regulations. IBM encourages owners of information technology (IT) equipment to  
responsibly recycle their equipment when it is no longer needed. IBM offers a  
variety of product return programs and services in several countries to assist  
equipment owners in recycling their IT products. Information on IBM product  
recycling offerings can be found on IBM’s Internet site at http://www.ibm.com/ibm/  
Notice: This mark applies only to countries within the European Union (EU) and  
Norway.  
This appliance is labelled in accordance with European Directive 2002/96/EC  
concerning waste electrical and electronic equipment (WEEE). The Directive  
determines the framework for the return and recycling of used appliances as  
applicable throughout the European Union. This label is applied to various products  
to indicate that the product is not to be thrown away, but rather reclaimed upon end  
of life per this Directive.  
In accordance with the European WEEE Directive, electrical and electronic  
equipment (EEE) is to be collected separately and to be reused, recycled, or  
recovered at end of life. Users of EEE with the WEEE marking per Annex IV of the  
WEEE Directive, as shown above, must not dispose of end of life EEE as unsorted  
municipal waste, but use the collection framework available to customers for the  
return, recycling and recovery of WEEE. Customer participation is important to  
minimize any potential effects of EEE on the environment and human health due to  
the potential presence of hazardous substances in EEE. For proper collection and  
treatment, contact your local IBM representative.  
© Copyright IBM Corp. 2006  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
40 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix D. Battery Return Program  
This product may contain sealed lead acid, nickel cadmium, nickel metal hydride,  
lithium, or lithium ion battery. Consult your user manual or service manual for  
specific battery information. The battery must be recycled or disposed of properly.  
Recycling facilities may not be available in your area. For information on disposal of  
batteries outside the United States, go to http://www.ibm.com/ibm/environment/  
products/batteryrecycle.shtml or contact your local waste disposal facility.  
In the United States, IBM has established a return process for reuse, recycling, or  
proper disposal of used IBM sealed lead acid, nickel cadmium, nickel metal hydride,  
and other battery packs from IBM Equipment. For information on proper disposal of  
these batteries, contact IBM at 1-800-426-4333. Please have the IBM part number  
listed on the battery available prior to your call.  
In Taiwan, the following applies:  
Please recycle batteries.  
© Copyright IBM Corp. 2006  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
42 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix E. Cable Warning  
WARNING: Handling the cord on this product or cords associated with accessories  
sold with this product, will expose you to lead, a chemical known to the State of  
California to cause cancer, and birth defects or other reproductive harm. Wash  
hands after handling.  
© Copyright IBM Corp. 2006  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
44 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix F. Additional DS4000 documentation  
The following tables present an overview of the IBM System Storage DS4000  
Storage Manager, Storage Subsystem, and Storage Expansion Enclosure product  
libraries, as well as other related documents. Each table lists documents that are  
included in the libraries and what common tasks they address.  
You can access the documents listed in these tables at both of the following Web  
sites:  
DS4000 Storage Manager Version 9 library  
Table 8 associates each document in the DS4000 Storage Manager Version 9  
library with its related common user tasks.  
Table 8. DS4000 Storage Manager Version 9.1 titles by user tasks  
Title  
User tasks  
Planning  
Hardware  
installation  
Software  
installation  
Configuration  
Operation and  
administration  
Diagnosis and  
maintenance  
IBM System  
Storage DS4000  
Storage Manager  
Version 9  
Installation and  
Support Guide for  
Windows  
U
U
U
2000/Server 2003,  
NetWare, ESX  
Server, and Linux  
IBM System  
Storage DS4000  
Storage Manager  
Version 9  
Installation and  
Support Guide for  
AIX®, UNIX®,  
Solaris and Linux on  
POWER™  
U
U
U
IBM System  
Storage DS4000  
Storage Manager  
Version 9 Copy  
Services User’s  
Guide  
U
U
U
U
U
U
U
U
IBM System  
Storage DS4000  
Storage Manager  
Version 9 Concepts  
Guide  
U
U
© Copyright IBM Corp. 2006  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4800 Storage Subsystem library  
Table 9 associates each document in the DS4800 Storage Subsystem library with  
its related common user tasks.  
Table 9. DS4800 Storage Subsystem document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM System Storage  
DS4800 Installation,  
User’s and  
U
U
U
U
U
U
U
Maintenance Guide  
IBM System Storage  
DS4800 Installation  
and Cabling  
Overview  
IBM TotalStorage  
DS4800 Controller  
Cache Upgrade Kit  
Instructions  
U
U
46 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4700 Storage Subsystem library  
Table 10 associates each document in the DS4700 Storage Subsystem library with  
its related common user tasks.  
Table 10. DS4700 Storage Subsystem document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM System Storage  
DS4700 Installation,  
User’s and  
U
U
U
U
U
U
Maintenance Guide  
IBM System Storage  
DS4700 Storage  
Subsystem Fibre  
Channel Cabling  
Guide  
Appendix F. Additional DS4000 documentation 47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4500 Fibre Channel Storage Server library  
Table 11 associates each document in the DS4500 (previously FAStT900) Fibre  
Channel Storage Server library with its related common user tasks.  
Table 11. DS4500 Fibre Channel Storage Server document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM TotalStorage  
DS4500 Installation  
and Support Guide  
U
U
U
U
IBM TotalStorage  
DS4500 Fibre  
Channel Cabling  
Instructions  
U
IBM TotalStorage  
DS4500 Storage  
Server User’s Guide  
U
U
U
IBM TotalStorage  
DS4500 Rack  
Mounting  
U
U
Instructions  
48 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4400 Fibre Channel Storage Server library  
Table 12 associates each document in the DS4400 (previously FAStT700) Fibre  
Channel Storage Server library with its related common user tasks.  
Table 12. DS4400 Fibre Channel Storage Server document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM DS4400 Fibre  
Channel Storage  
Server User’s Guide  
U
U
U
U
U
U
U
U
U
IBM DS4400 Fibre  
Channel Storage  
Server Installation  
and Support Guide  
U
U
IBM DS4400 Fibre  
Channel Cabling  
Instructions  
Appendix F. Additional DS4000 documentation 49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4300 Fibre Channel Storage Server library  
Table 13 associates each document in the DS4300 (previously FAStT600) Fibre  
Channel Storage Server library with its related common user tasks.  
Table 13. DS4300 Fibre Channel Storage Server document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM TotalStorage  
DS4300 Fibre  
Channel Storage  
Server Installation  
and User’s Guide  
U
U
U
IBM TotalStorage  
DS4300 Rack  
Mounting  
U
U
U
U
Instructions  
IBM TotalStorage  
DS4300 Fibre  
Channel Cabling  
Instructions  
IBM TotalStorage  
DS4300 SCU Base  
Upgrade Kit  
U
U
U
U
IBM TotalStorage  
DS4300 SCU Turbo  
Upgrade Kit  
IBM TotalStorage  
DS4300 Turbo  
Models 6LU/6LX  
Upgrade Kit  
U
U
50 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4100 SATA Storage Server library  
Table 14 associates each document in the DS4100 (previously FAStT100) SATA  
Storage Server library with its related common user tasks.  
Table 14. DS4100 SATA Storage Server document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM TotalStorage  
DS4100 Installation,  
User’s and  
U
U
U
U
U
U
Maintenance Guide  
IBM TotalStorage  
DS4100 Cabling  
Guide  
Appendix F. Additional DS4000 documentation 51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
DS4000 Storage Expansion Enclosure documents  
Table 15 associates each of the following documents with its related common user  
tasks.  
Table 15. DS4000 Storage Expansion Enclosure document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM System Storage  
DS4000 EXP810  
Storage Expansion  
Enclosures  
U
U
U
U
U
Installation, User’s,  
and Maintenance  
Guide  
IBM TotalStorage  
DS4000 EXP700  
and EXP710  
Storage Expansion  
Enclosures  
Installation, User’s,  
and Maintenance  
Guide  
U
U
U
U
U
U
U
U
Fibre Channel  
Solutions - IBM  
DS4000 EXP500  
Installation and  
User’s Guide  
U
U
U
U
IBM System Storage  
DS4000 Hard Drive  
and Storage  
Expansion  
Enclosures  
Installation and  
Migration Guide  
52 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Other DS4000 and DS4000-related documents  
Table 16 associates each of the following documents with its related common user  
tasks.  
Table 16. DS4000 and DS4000–related document titles by user tasks  
Title  
User Tasks  
Planning  
Hardware  
Software  
Configuration  
Operation and  
Diagnosis and  
Installation  
Installation  
Administration Maintenance  
IBM Safety  
Information  
U
IBM TotalStorage  
DS4000 Quick Start  
Guide  
U
U
IBM TotalStorage  
DS4000 Hardware  
Maintenance Manual  
U
U
IBM System Storage  
DS4000 Problem  
Determination Guide  
IBM Fibre Channel  
Planning and  
Integration: User’s  
Guide and Service  
Information  
U
U
U
U
U
U
U
U
IBM TotalStorage  
DS4000 FC2-133  
Host Bus Adapter  
Installation and  
User’s Guide  
IBM TotalStorage  
DS4000 FC2-133  
Dual Port Host Bus  
Adapter Installation  
and User’s Guide  
IBM System Storage  
DS4000 Fibre  
Channel and Serial  
ATA Intermix  
Premium Feature  
Installation Overview  
U
U
U
U
U
IBM Netfinity Fibre  
Channel Cabling  
Instructions  
IBM Fibre Channel  
SAN Configuration  
Setup Guide  
U
U
U
U
Appendix F. Additional DS4000 documentation 53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
54 IBM System Storage DS4000 FC 4Gbps PCI-X Single/Dual Port HBA: Installation and User’s Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
adapter  
F
Fast!UTIL settings  
B
before you begin installing  
H
host adapter bracket  
C
cables  
host adapter settings  
I
D
installing  
documentation  
L
M
DS4000 FC 4Gbps PCI-X Host Bus Adapter  
N
notices  
DS4000 Storage Manager  
O
© Copyright IBM Corp. 2006  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢀꢁꢂꢃ  
Part Number: 39M5599  
Printed in USA  
GC26-7814-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grundig Computer Monitor GUVL1500 User Manual
Hamilton Beach Blender 544 EMMIE User Manual
Hamilton Beach Stereo System 840095500 User Manual
Hans Grohe Indoor Furnishings 10120XX1 User Manual
Harbor Freight Tools Home Safety Product 03358 User Manual
Hasbro Games Kacheek User Manual
Honeywell Air Cleaner F111 User Manual
HP Hewlett Packard Computer Drive 460i User Manual
Huffy Fitness Equipment P N 21147703 User Manual
IKEA Indoor Furnishings AA 173891 1 User Manual