Hypercom Scanner ICE 5500Plus User Manual

Figure 3  
ICE 5500Plus Terminal  
Installing an Optional Line Splitter  
The Hypercom® epic (ePOS-infocommerce™) ICE™ 5500Plus combines the flexibility of a full  
featured, smart-card ready (HyperSmart™) integrated POS terminal with the infrastructure to quickly  
and cost-effectively integrate new applications. This combination makes ICE (Interactive Consumer  
Enviroment) the simplest and most innovative POS solution available today. The ICE 5500Plus  
incorporates the new integrated modem technology, Hypercom FastPOS™. Operating at 9600 bps,  
FastPOS allows for lower transaction costs, new data-rich applications such as signature capture, and  
faster transactions.  
If connection to an extension telephone is needed, use the following  
procedure to install a Hypercom Line Splitter:  
Note: The terminal disconnects the PHONE port when a transaction is  
Phone Port  
being processed.  
Line Port  
1. Insert the Line Splitter into the terminal port labeled LINE. See Figure 2.  
Figure 4  
2. Insert the line from the extension phone into the port labeled PHONE  
on the Line Splitter. See Figure 3.  
Installation Procedures  
Note: The following equipment warnings are for your safety and that of your equipment.  
3 Insert the line from the wall receptacle into the port lableled LINE.  
See Figure 3.  
WARNING:  
Do not use an ungrounded adapter, power adapter, power extender cable, or AC outlet.  
Do not disassemble the AC adapter. Only qualified technicians may service the adapter.  
The AC adapter is intended for indoor use only; do not expose to rain or snow.  
Do not immerse in fluid.  
Loading Paper  
Use the following procedure to load paper into the ICE 5500Plus terminal:  
Paper Cover Tabs  
The reliability of this equipment is significantly reduced when it is powered from  
an ungrounded AC power outlet.  
Note: Use only thermal roll paper.  
1. Squeeze the paper cover tabs and lift open the paper cover. See Figure 4.  
Ensure that the telephone line is disconnected when the unit is unplugged from the AC  
power outlet.  
Figure 5  
2. Place the paper roll into the holder so the paper feeds from under the roll.  
Pull the end of the paper roll over the printer. See Figure 5.  
Do not use a pen on the screen display. Pens and other sharp objects will scratch or  
damage the screen display.  
3. While holding the end of the paper roll, close the paper cover. See Figure 5.  
You will hear the paper cover click when properly latched. See Figure 4.  
Powering Up the Terminal  
Figure 1  
Use the following procedure to power up the ICE 5500Plus:  
4. Tear off the excess paper.  
1. Connect the +24-VDC power cable from the AC adapter to the  
three-pin terminal power socket on the back panel of the ICE 5500Plus.  
See Figure 1.  
Attaching the Stylus  
Paper Roll  
Use the following procedure to attach the Stylus to the ICE 5500Plus:  
2. Plug the adapter into a grounded AC power outlet. Be sure the  
connector is firmly seated. When the power is properly connected the  
terminal beeps twice then performs a self-test routine.  
1. Peel the paper backing from the Stylus holder. See Figure 6.  
Figure 6  
Power  
RS-232  
2. Press the Stylus holder on the desired position. Hypercom recommends  
placing the Stylus on the side of the paper holder, or on the body of the  
terminal. See Figure 7.  
Connecting the Telephone Line  
Figure 2  
Note: Only use the provided Stylus on the screen display.  
Use the following procedure to connect a telephone line to the ICE 5500Plus:  
1. Insert the telephone cable shipped with the ICE 5500Plus terminal into a  
dedicated analog telephone outlet.  
Cleaning the ICE 5500Plus  
Paper Backing  
Figure 7  
Stylus Holder  
Use the following procedure to clean the casing and the printer mechanism  
of the ICE 5500Plus:  
WARNING: DO NOT insert the telephone line into the PIN pad port.  
WARNING: DO NOT use undiluted ammonia, or abrasive cleaners.  
2. Insert the other end of the telephone cable into the port labeled LINE on  
the back panel of the ICE 5500Plus terminal and make sure it is fully seated.  
See Figure 2. The use of a different cable may result in improper operation.  
PIN  
Line  
-Apply denatured alcohol or a Windex®-type product to a clean, soft  
non-abrasive, low-lint cloth. Carefully wipe the entire terminal,  
including the touch screen and keypad.  
Note: Ensure that the telephone line cable latches are firmly locked into the  
jacks on both the ICE 5500Plus terminal and wall receptacle.  
-As needed, use anti-static compressed air to clean in and  
around the printer mechanism  
Paper Holder  
Stylus Holder  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grundig CRT Television MFS 55 4601 8 User Manual
Harbor Freight Tools Air Compressor 47407 User Manual
Harbor Freight Tools Air Compressor 90385 User Manual
Harbor Freight Tools Lawn Mower 96154 11HP User Manual
Hasbro Robotics 85894 User Manual
Hotpoint Microwave Oven RVM1625 User Manual
HP Hewlett Packard Switch 372284 001 User Manual
Huawei Cell Phone M865 User Manual
Hubbell Switch LXi 1800 User Manual
Imperial Range Fryer IFS 75 User Manual