Honeywell Home Security System 800 06894 User Manual

LYNX Touch  
Security System  
User Guide  
Ready To Arm  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Message  
Phone  
More  
10:18 AM June 8, 2010  
ARMED  
READY  
800-06894 1/11 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SYSTEM OVERVIEW..................................................................................................................................5  
Features...................................................................................................................................................5  
General Operation...................................................................................................................................6  
Quick View of System Functions............................................................................................................9  
About the Touchscreen Control ............................................................................................................10  
Touchscreen Control Definitions ..........................................................................................................11  
About the Display and Indicators.........................................................................................................13  
Navigating Menus.................................................................................................................................15  
SECURING THE PREMISES..................................................................................................................17  
System Status........................................................................................................................................17  
Arming the System................................................................................................................................18  
Entry/Exit Delays..................................................................................................................................23  
Disarming the System...........................................................................................................................25  
Bypassing Protection Zones..................................................................................................................27  
Panic Keys .............................................................................................................................................29  
Chime Mode...........................................................................................................................................31  
Voice Mode.............................................................................................................................................32  
USER FUNCTIONS...................................................................................................................................33  
User Access............................................................................................................................................33  
View Events...........................................................................................................................................37  
Message Recording and Playback.........................................................................................................39  
System Adjustment...............................................................................................................................41  
Clock/Calendar ......................................................................................................................................43  
Programming Devices ...........................................................................................................................45  
Scheduling User Interface ....................................................................................................................49  
Reminders..............................................................................................................................................52  
Speaker Phone Feature.........................................................................................................................55  
Remote Phone Control Feature ............................................................................................................57  
Remote Services ....................................................................................................................................59  
FIRE/CO ALARM SYSTEM......................................................................................................................60  
General Information..............................................................................................................................60  
National Fire Protection Association’s Smoke Detector Recommendations.......................................61  
Emergency Evacuation .........................................................................................................................62  
SYSTEM FUNCTIONS..............................................................................................................................63  
Testing the System................................................................................................................................63  
Maintaining Your System.....................................................................................................................65  
Congratulations on your ownership of a Honeywell Security System. You have made a wise  
decision in choosing it, for it represents the latest in security protection technology today.  
Honeywell is the world's largest manufacturer of security system and millions of premises are  
protected by Honeywell products.  
3 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS...................................................................67  
System Displays ....................................................................................................................................68  
Zone Status Icons ..................................................................................................................................68  
Regulatory Agency Statements....................................................................................................................69  
FCC STATEMENTS ..................................................................................................................................70  
OWNER’S INSURANCE PREMIUM CREDIT REQUEST..................................................................73  
LIMITATIONS OF THIS ALARM SYSTEM..........................................................................................76  
INDEX..........................................................................................................................................................77  
TWO YEAR WARRANTY..........................................................................................................................79  
4 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
Features  
General Information  
This system offers you three forms of protection: burglary, fire, and emergency, depending on  
the configuration of your system. The system consists of a touchscreen control for system  
operation, various wireless sensors that provide perimeter and interior burglary protection,  
and optional smoke or combustion detectors to provide early fire warning. In addition,  
optional wireless keypads may have been installed to allow you to control the system away  
from the touchscreen control. The system may also be used as a speaker phone.  
The system monitors protection zones and system status, displays appropriate information  
on the touchscreen display, and initiates appropriate alarms. Your system may also have  
been programmed to automatically send alarm or status messages over the phone lines or via  
the cellular/GSM network or the internet to a central alarm monitoring station, and may also  
be capable of two-way voice communication with the central station.  
The user features of this security system are listed below. Ask your installer which  
features have been programmed for your system.  
STAY and AWAY arming modes: By using these modes you can protect either the  
perimeter only, or the entire premises.  
Panic key functions: A designated key allow you to manually activate fire, medical  
emergency, or silent police alarms. Refer to the PANIC KEYS section for detailed  
information.  
Follow me reminder announcements: Allows the panel to dial a number that you have  
specified, at a programmed time and day and deliver a message programmed by your  
installer.  
Real-time clock: Touchscreen displays current date and time. Refer to the  
CLOCK/CALENDAR section for procedures for setting the time.  
Message center: The system allows recording and play back of brief messages. Refer to  
the RECORDING/PLAYBACK MESSAGES section for procedures.  
Two-way voice: Allows the central station to listen, talk to or conduct two-way  
conversations with individuals on the premises Refer to the TWO-WAY VOICE section for  
detailed information.  
Phone Control: Provides a remote interactive phone capability that permits access to the  
security system from any off-site touch-tone telephone. Refer to the Remote Phone Control  
Feature section for detailed information.  
Speaker Phone Operation: The system is capable of operating as a speaker phone  
allowing hands free telephone conversation.  
Security Codes: The system is capable of supporting an Installer code, Master user code  
and 14 additional User codes including Babysitter and Duress codes. Refer to the  
SECURITY CODES section for detailed information.  
5 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
General Operation  
Device activation: Allows you to send Follow-Meor e-mail messages, as a result of a  
system event such as an alarm or trouble condition. Refer to the DEVICES section for  
detailed information.  
Scheduling feature: Allows you to schedule the automatic activation or deactivation of  
program events (e.g. alarm clock, reminder, and latch key). Refer to the SCHEDULES  
section for detailed information.  
Zones  
Your system's sensing devices have been assigned to various "zones." For example, the  
sensing device on your entry/exit door may have been assigned to zone 01, sensing devices on  
windows in the master bedroom to zone 02, and so on. These numbers appear on the display  
when an alarm or trouble condition occurs.  
Fire Protection  
The fire protection portion of your security system (if used) is always active and will sound  
an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for  
important information concerning fire protection, smoke detectors and planning emergency  
exit routes from the premises.  
Carbon Monoxide  
The carbon monoxide (CO) portion of your security system (if used) is always active and will  
sound an alarm if a CO condition is detected. Refer to the FIRE ALARM SYSTEM section for  
more information.  
Burglary Protection  
Your system provides two modes of burglary protection: STAY and AWAY. STAY mode  
protects the perimeter only, allowing you to freely move inside the premises. AWAY mode  
protects the entire system. Both modes provide an entry delay time that allows you to  
reenter the premises without setting off an alarm. For additional security, you can turn the  
entry delay off when arming the system. Refer to the ARMING THE SYSTEM section. The  
system also allows you to bypass selected zones before arming the system, if desired. Refer to  
the BYPASSING PROTECTION ZONES section. The system also provides a CHIME mode,  
for alerting users to the opening of protected doors and windows while the system is  
disarmed.  
You must arm the burglary protection portion of your system before it will sense burglary  
alarms. Refer to the ARMING THE SYSTEM section for detailed procedures and  
information.  
6 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
General Operation  
LYNX Touch SIA False Alarm Prevention Features  
Many false alarms are caused by simple accidents, like forgetting to close a door when you leave. The  
LYNX Touch SIA includes several features that help prevent false alarms and some of these are  
optional or programmable. Although turning off some of these features may provide additional security,  
it may also increase the chance of false alarms. Your installer can help you decide whether to use the  
features or not. The following provides a brief explanation of the features included with your security  
system that help prevent false alarms from occurring, and what you should do if such alarms occur.  
Exit/Entry Delays: Your security system has been programmed with delay times that allow you to  
exit the premises after arming, and to disarm the system upon entry, before an alarm occurs. If you  
leave the premises too late when exiting, or disarm too late when arriving home, it will cause a false  
alarm. If an alarm occurs, you should disarm the system immediately, and wait for your monitoring  
company to call you.  
Exit Alarms: Leaving the premises and forgetting to close the door is a common cause of false  
alarms. The security system will sound an alarm, and display Exit Error. The security system  
provides extra time for you to disarm the system before dialing your monitoring company. Disarming  
the system immediately may prevent a call to your monitoring company.  
Exit Time Restart-Exit Delay Restart/Reset: If you leave the premises and enter again before the  
exit delay has expired, the system will restart the exit time giving you more time to leave. If there  
are less than 10 seconds left to exit, the system will sound fast beeps, indicating an alarm will occur  
soon if you fail to exit or disarm immediately. If this occurs, disarm the system and arm it again  
when you are ready to leave. The Exit Delay can also be restarted by pressing the RESTART Icon.  
Auto Stay Feature: If you arm the system in the AWAYmode from the controls keypad or an RF  
keypad but no one exits, the alarm system will automatically change to the STAYmode. This will  
prevent you from tripping alarms by remaining on premises. Disarm the system and arm away again  
when you are ready to leave.  
Burglary Abort Window: Your security system has a delay between the time a burglary alarm  
sounds, and the time the monitoring company is called. This delay gives you time to disarm the  
security system before the alarm is reported to the monitoring company. This delay is factory preset  
at 30 seconds, but may be increased or decreased by your installer.  
False Alarms: If a burglary or fire alarm condition occurs and the system has been disarmed, the  
keypad will display Alarm Cancelled. If this was a false alarm, wait for the monitoring company to  
call you. They will verify your security code or password and prevent them from calling emergency  
personnel to respond to a false alarm.  
7 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
General Operation  
Security Codes  
At the time of installation, you were asked to provide a personal 4-digit security or Master  
Usercode. You must enter the user code when arming and disarming the system, and when  
performing other system functions. As an additional security feature, other users who do not  
need to know your code can be assigned up to 14 different security codes. Refer to the  
SECURITY CODES section for procedures on adding security codes to the system.  
Alarms  
When an alarm occurs, the LYNX Touch internal sounder will sound for about 15-seconds,  
and the touchscreen displays the zone(s) causing the alarm. After 15-seconds, the internal  
sounder stops temporarily and voice announcements of the zones in alarm begins. When  
these zones have been announced, the internal sounder sounds again and the cycle repeats  
itself, until the system is disarmed or until alarm bell timeout occurs. If your system is  
connected to a central monitoring station, an alarm message will be sent. To stop the alarm  
sounding, simply disarm the system. The zone(s) causing the alarm remain displayed  
indicating memory of alarm. Refer to the DISARMING THE SYSTEM section for  
information about clearing the memory of alarm display  
Two-Way Voice Feature  
The control supports voice dialog between an operator at the central station and an  
individual at the premises. This feature allows the central station to listen, talk to or conduct  
a two-way conversation with an individual(s) at the premises and allows the operator to  
gather information about the nature and location of the alarm that may be helpful in  
responding to police or rescue departments. If the Two-way Voice Feature has been  
programmed and an alarm condition is detected, the system sends an alarm message to the  
central station. After acknowledgement is received, a listen in to followmessage is sent to  
the central station. In response to this message, the central station operator can enter  
commands that allow him to initiate a 5-minute voice session.  
If a subsequent zone is violated during a voice session, the system will terminate the session  
and process the alarm. During the voice session, the ARMED (red) and READY (green) LEDs  
will alternately blink in the Talk and VOX Modes but not during Listen Mode.  
8 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK VIEW OF SYSTEM FUNCTIONS  
SECURITY FUNCTIONS  
Checking system status: .............................................Select “System” icon.  
To arm in STAY mode: ..............................................Select “Stay” icon then enter Code.  
To restart exit delay: ...................................................Select “Restart Exit Delay” icon.  
To arm in AWAY mode: .............................................Select “Away” icon or depress “Away” key then enter  
Code.  
To arm INSTANT: ......................................................Set “Delay” to ”Instant” . Select “Stay” or “Away” icon  
or “Away” key then enter code.  
To arm if Quick Arm* is active: ....................................Select “Stay” or “Away” icon or “Away” key followed  
by Quick Arm tab on the touchscreen.  
*
User code is not required if Quick Arm is active.  
To disarm system and silence alarms:......................... Depress “Off’” key or “Disarm” icon and enter Code  
Note: During Entry Delay or when an Alarm Condition exists, the LYNX Touch can be disarmed by entering the User  
Code. Entering the OFF key is not required  
To bypass a zone(s): ..................................................Select “Zones” icon  
To turn Chime mode on or off: ....................................Select “Settings” icon  
MESSAGE CENTER  
To record a message: .................................................Select “Message” icon  
VOLUME ADJUSTMENT  
To adjust volume: ........................................................Select “Settings” icon  
To restore/unmute user announcements: ....................Select “Settings” icon  
SPEAKER PHONE OPERATION  
To enter speaker phone mode:....................................Select “Phone” Icon  
To enable/disable (toggle) ringer: ................................Select “Settings” icon  
OTHER FUNCTIONS (accessible to the Master User only)  
To set the time and date: .............................................Select “Date Time” icon (on Master User Menu)  
To set scheduling:........................................................Select “Schedules” icon (on Master User Menu)  
To activate/deactivate devices:....................................Select “Devices” icon (on Master User Menu)  
To add/delete a user code* (except Master Code):......Select “Users” icon (on Master User Menu)  
* Only the master code can be used to add or delete another user code.  
To turn Test mode On or Off:.......................................Select “Test” icon (on Master User Menu)  
To view system events:................................................Select “Events” icon (on Master User Menu)  
To program or delete “Follow Me” Reminders: ............Select “Reminders” icon (on Master User Menu)  
9 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
About the Touchscreen Control  
General  
**IMPORTANT**  
If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred  
during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY  
and CONTACT THE POLICE from a nearby safe location.  
The touchscreen icons and keys allow you to control all system functions. Additionally, the  
touchscreen display shows the zone and description of all system occurrences. When the  
speaker phone mode is active, a full-function telephone keypad is displayed on the  
touchscreen.  
The system also features a built-in sounder, which will sound during alarms and troubles  
and a built-in speaker announces system status. Additionally, the system "beeps" during  
certain system functions, such as during entry/exit delay times, in Chime mode, and when  
depressing any of the keys (to acknowledge the key press).  
The voice announcement volume is adjustable, however the beepsthat sound in response to  
alarms always sound at the maximum volume level. All other beeps(trouble, chime,  
exit/entry, etc) can be set to either low or high volume.  
ARMED  
READY  
5000-100-002-V0  
10 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
Touchscreen Control Definitions  
1
2
9
8
3
ARMED  
READY  
4
7
6
5
5000-100-051-V0  
Note: The system functions described below are for reference only and require additional key entries to  
activate.  
1. DISPLAY WINDOW: Color Liquid Crystal Display (LCD). Displays system status icons, time,  
system status information, user menus and the virtual keypad.  
2. READY Indicator (LED): (GREEN) When lit, indicates system is ready to be armed; blinking  
indicates system is not ready (a zone is open). Blinks once per second when AVM (VOX or Talk) or  
speaker phone mode is active.  
3. HOME Key: Used to exit from a screen or return to the home screen.  
4. Speaker: Source of audible internal warning and confirmation sounds, status announce-  
ments, as well as alarms (see "Summary of Audible Notifications").  
11 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
Touchscreen Controls Definitions  
5. OFF (Disarm) KEY: Initiates the disarm process and causes a keypad to be displayed on  
the touchscreen. Disarms the burglary portion of the system, silences alarms and audible  
trouble indicators, and clears alarm trouble display after the problem has been corrected.  
6. AWAY KEY: Completely arms both perimeter and interior burglary protection for backup  
protection by sensing an intruder's movements through protected interior areas as well as  
guarding protected doors, windows, etc. Entrance can be made through an entry delay  
zone without causing an alarm if the system is disarmed before the entry delay time  
expires.  
7. PANIC Key: When depressed for 4 seconds, the virtual panic icons are displayed on the  
touchscreen.  
MICROPHONE: Used to record personal messages via the Message Center, and for two-  
8.  
way voice and speaker phone operation.  
9. ARMED Indicator (LED): (RED) Lit when the system has been armed (STAY, AWAY).  
Blinks when armed and fault exists, or once per second when AVM (VOX or Talk) or  
speaker phone mode is active.  
LED Meanings  
ARMED LED:  
ON = System armed  
(Red)  
OFF = System disarmed  
Blinking = System armed, and an alarm is in progress or was previously.  
Blinking alternately with READY LED = speaker phone mode is active  
ON = System disarmed, ready to arm  
READY LED:  
(Green)  
OFF = System armed  
Blinking = System disarmed, not ready to arm (a fault exists)  
Blinking alternately with ARMED LED = speaker phone mode is active.  
12 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
About the Display and Indicators  
Display Definitions  
DEFINITION  
ICON  
TEXT  
Ready to  
Arm  
Displayed along with the the text READY TO ARMwhen  
system is Disarmed and ready to arm.  
Armed Awayis displayed along the top of the screen. An  
armed away icon along with Armed Awayis displayed after  
the exit delay expires.  
Armed  
Away  
Armed Stay  
Armed Stayis displayed along the top of the screen. An  
armed stay icon along with Armed Stayis displayed after the  
exit delay expires.  
Exit Now  
Armed Stay Exit Nowor Armed Away Exit Nowis  
displayed in a red band along the top of the screen. An exit  
icon along with Exit Nowand the time remaining (i.e.; 28  
Seconds) is displayed during the exit delay.  
28 Seconds  
when the system is armed in the Stay mode. The text Armed:  
Stay Exit NowOnce the exit delay expires Armed: Stayis  
displayed along with the Home Screen.  
Note: Display alternates with ARMED STAY icon and text  
Alarm  
Alarmis displayed in a red band along the top of the screen.  
An alarm (bell) icon along with Alarmis displayed alternately  
with the Zone that has caused the alarm.  
Not Ready To Arm Faultis displayed in a yellow band  
along the top of the screen. An open windowor door icon  
along with the zone descriptor and Windowor Dooris  
displayed when a window or entry/exit fault has been  
detected.  
Fault (Zone  
No.&  
Description)  
OR  
OR  
Displayed alternately with the alarm (bell) icon and Alarm.  
Alarmis also displayed in a red band along the top of the  
screen.  
13 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
About the Display and Indicators  
DEFINITION  
ICON  
TEXT  
Fire OR  
Fire Alarm  
95 Fire  
The fire icon is displayed with alternating text Fireand Fire  
Alarm 95 Fire. Fire Alarmis also displayed in a red band  
along the top of the screen.  
The Medical icon isplayed when a medical alarm is activated.  
Alarmis also displayed in a red band along the top of the  
Alarm 96  
Medical  
screen.  
(If programmed for display by your installer)  
The alarm (bell) icon when a burglary alarm is activated.  
Alarmis also displayed in a red band along the top of the  
screen.  
Alarm 99  
Police  
(If programmed for display by your installer)  
Displayed alternately with the alarm (bell) icon when a CO  
alarm is activated.  
CO Alarm  
Alarmis also displayed in a red band along the top of the  
screen.  
A check system icon along with Cover Tamperis displayed  
when a cover tamper has been detected. Ready To Arm –  
System Troubleis displayed in a yellow band along the top of  
the screen.  
Cover  
Tamper  
The system has identified a problem with the telephone dialer.  
Reporter  
Failure  
Not Ready To Arm System Troubleis displayed in a yellow  
band along the top of the screen. A low battery icon along with  
Low Batteryis displayed when the systems backup battery  
power is low.  
Low  
Battery  
Appears when the system has detected an RF jamming  
condition or excessive interference.  
90 RF Jam  
Appears when the system has detected a loss of telephone  
service.  
94 Phone  
Line Cut  
Displayed when the system has lost AC power. Ready To  
Arm System Troubleis displayed in a yellow band along the  
top of the screen.  
AC Loss  
14 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
Navigating Menus  
LCD Display  
LYNX Touchs Liquid Crystal Display (LCD) touch-screen displays variable icons and text on  
screens. The screen displays status icons and associated text, the current time, system  
status information and menu choices. The system status is displayed in a colored band along  
the top of the screen. The band color is variable and will change between red, yellow and  
green as the system status changes.  
The Menu area includes a list of commands, or choices that apply to the current selection.  
The status area provides information about various system events. A Home Screenis  
displayed whenever power is applied to the system. In addition the green READYLED will  
be lit.  
SYSTEM  
STATUS  
Ready To Arm  
SYSTEM/ZONE  
STATUS  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-054-V0  
LYNX Touch Home Screen (page 1)  
Navigation Keys  
Navigating through the screens is accomplished by lightly touching the menu item on the  
touch-screen. Once activated, the control will take you to the next screen. Selecting the  
Home(cancel) key or the 2Key will return you to the home screen at any time unless  
System Programming mode is active.  
Note: You may find it convenient to adjust the volume setting before entering the Program (Tools) Mode.  
This will allow you to clearly hear the feedback announcements or system beeps in the Programming  
Mode, of the systems built-in speaker. To adjust the volume, select Moreon the home Screenand  
then select Settings. Adjust the volume using the slide shown on the Settings screen and then  
select Saveto accept.  
15 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM OVERVIEW  
Navigating Menus  
Menu Screens  
System Status is displayed at the top of each screen. The time and date are displayed at the  
bottom of the Home Screen.  
Menus  
Unrestricted Menu  
The first page of the Home Screen provides access to an Unrestricted Menu displays the  
system status and eight selection icons or buttons.  
1. Zones Provides access to Zone information and options.  
2. System Provides information about system status.  
3. Arm Away Used to Arm the system in Away mode.  
4. Arm Stay Used to Arm the system in Stay mode.  
5. Message Provides access to Message Center.  
6. Phone Provides access to Speaker Phone mode (if programmed).  
7. Delay/Instant Used to toggle between exit delay and instant arming options.  
8. More Advances system to second page of the Home Screen.  
The second page of the Home Screen displays the system status in and seven options.  
1. Tools Provides access User Programming Menus (Master User Code required for  
access).  
2. Arm Away Used to Arm the system in Away mode.  
3. Arm Stay Used to Arm the system in Stay mode.  
4. Settings Provides access to various touchscreen functions including Brightness,  
Contrast, Volume, Voice, Chime and Ringer.  
5. Delay/Instant Used to toggle between exit delay and instant arming options.  
6. Back Returns system to first page of the Home Screen.  
Master Menu  
The User Menu provides access to User configurable features and displays eight options.  
Entering the Master User Code is required to access the Master menu.  
1. Users Allows Master User to add or remove User Codes  
2. Devices Allows Master User to program output triggers.  
3. Schedules Allows Master User to program schedules  
4. Test Allows Master User to Test the system  
5. Date Time Used to program date and time.  
6. Events Allows Master User to view system events  
7. Reminders Allows Master User to add or remove local and Follow Mereminders.  
8. Slide Show Allows Master User to select a slide show for use as a screensaver.  
9. Back Returns system to first page of the Home Screen.  
16 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
System Status  
General Information  
Before arming your system, all protected doors, windows, and other protection zones must be  
closed or bypassed (see the BYPASSING PROTECTION section).  
READY LED: The green READY indicator on the control will be lit if the system is ready to  
be armed. If blinking, the system is not ready.  
NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the  
current state of the system.  
Depending on the current state of the system the following phrases may be heard:  
fire alarm [zone voice descriptors]  
carbon monoxide alarm [zone voice descriptors]  
alarm [zone voice descriptors]  
fire fault [zone voice descriptors]  
carbon monoxide fault [zone voice descriptors]  
fault [zone voice descriptors]  
low battery [zone voice descriptor]  
system low battery  
check system  
AC loss  
zones bypassed  
chime  
VOLUME LEVEL: The volume level of system announcements can be increased or decreased. Refer to  
the MESSAGE RECORDING/PLAYBACK section for the procedure.  
System Can Be Armed  
The READY LED will be lit steadily once all protection zones have been closed or bypassed.  
You may now arm the system.  
17 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Arming the System  
Arming in Stay Mode  
Use this mode when you are staying home, but expect someone to use the entrance door  
later. Close all protected perimeter windows and doors before arming. The green READY  
indicator on the control should be lit if the system is ready to be armed. When armed in  
STAY mode, the system will sound an alarm if a protected door or window is opened, but you  
may otherwise move freely throughout the premises. Late arrivals can enter through the  
designated entrance door without causing an alarm, but they must disarm the system within  
If Quick Arm was programmed by the installer,  
the entry delay period or an alarm will occur.  
you do not need to enter the security code to arm the system. The security code must always  
be used to disarm the system, however.  
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm  
the system. In addition, if the system is armed by pressing via Quick-Arming, neither the  
Babysitter Code nor Installer Code can disarm the system.  
Ready To Arm  
1. Select the Arm Stay icon, the system will  
beep once and display a keypad.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2. Enter a valid User Code.  
OR  
Arm the system in Stay mode  
1
2
5
8
0
3
6
9
If Quick Arm has been enabled, select the  
Quick Armicon.  
Enter Code:  
4
7
The system will beep three times and  
announce Armed Stay Exit Now. The exit  
delay screen will be displayed. If  
programmed the display will count down  
the time remaining in the exit delay.  
Cancel  
Clear  
5000-100-137-V0  
Note: If a valid user code is not entered or the  
Confirm icon has not been selected within  
10 seconds, the system will return to the  
homescreen and it will not be armed.  
– 18 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Arming the System  
Armed: Stay  
3.  
At the end of the exit delay the system  
will announce Armed Stayand  
display the Armed Stayscreen.  
Zones  
System  
Disarm  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-056-V0  
If an invalid User Code is entered, the system will return to the home screen.  
Auto Stay Feature  
If this feature is enabled by installer, the LYNX Touch SIA, when armed AWAY from the controls  
keypad or a Wireless Keypad, switches to the STAY mode if the Exit Time expires and no exit has been  
made.  
NOTE: If the exit route entry/exit sensor is in a check condition or has been bypassed it will result in a loss of interior  
protection because the alarm system will arm STAY in this case. Consult with your installer for servicing of the  
entry exit zones or to turn off this feature if a check condition on entry exit zones occurs.  
19 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Arming the System  
Arming In Away Mode  
Use this mode when no one will be staying on the premises. Close all protected perimeter  
windows and doors before arming. The green READY indicator on the control should be lit if  
the system is ready to be armed. When armed in AWAY mode, the system will sound an  
alarm if a protected door or window is opened, or if any movement is detected inside the  
premises, when infrared detection devices are used. You may leave through a designated  
entrance door during the exit delay period without causing an alarm. You may also re-enter  
through the entrance door, but you must disarm the system within the entry delay period or  
If Quick Arm was programmed by the installer, you do not need to enter  
an alarm will occur.  
the security code to arm the system. The security code must always be used to disarm the  
system, however.  
The Babysitter Code and Installer Code cannot disarm the system unless it was used to arm  
the system. In addition, if the system is armed by pressing via Quick-Arming, neither the  
Babysitter Code nor Installer Code can disarm the system.  
Ready To Arm  
1. Select the Arm Away icon, the system will  
beep once and display a keypad.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2.  
Enter a valid User Code.  
OR  
Arm the system in Away mode  
1
2
5
8
0
3
6
9
If Quick Arm has been enabled, select the  
Quick Armicon.  
The system will beep two times and announce  
Armed Away Exit Now. The exit delay screen  
will be displayed. If programmed the display  
will count down the time remaining in the exit  
delay in seconds.  
Enter Code:  
4
7
Cancel  
Clear  
5000-100-053-V0  
Note: If a valid user code is not entered or the Confirm  
icon has not been selected within 10 seconds,  
the system will return to the homescreen and it  
will not be armed.  
20 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Arming the System  
Armed: Away  
3.  
If Exit Warninghas been enabled, the  
system will continue to beep throughout  
the exit delay. Rapid beeps will sound for  
the final 10 seconds of the delay period. At  
the end of the exit delay the system will  
announce Armed Awayand displays the  
Armed Awayscreen.  
Zones  
System  
Disarm  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-057-V0  
If an invalid User Code is entered, the system will return to the home screen.  
21 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Arming the System  
Arming the System with no delay (Instant)  
Use Instantwith Stay mode when you are staying home and do not expect anyone to use  
the entrance door.  
Use Instantwith Away mode when the premises will be vacant for extended periods of time  
such as vacations, etc.  
When armed with Instant, the control beeps twice, or beeps continuously if exit warning  
has been programmed for your system, and displays the Armed Stay Instantor Armed  
Away Instantmessage. The red ARMED indicator lights and the system announces Armed  
Stay Instant –exit nowor Armed Away Instant –exit now.  
When armed with Instant, the system will sound an alarm if a protected door or window is  
opened, including the entrance door. You may leave through the entrance door during the  
exit delay period without causing an alarm, but an alarm will sound as soon as someone  
reenters.  
To arm the system with no delay (Instant)  
Ready To Arm  
1. Select the Delaytab on the home screen.  
The icon will toggleand Instantwill be  
displayed.  
2. Arm the system in the Stayor Awaymode  
Zones  
System  
normally.  
Note: The entry delay time is eliminated when  
Instantis selected.  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Quick Exit  
If active, you can restart the exit delay at any time after arming has been armed in Stay or  
Away mode by selecting the Quick Exiticon. This avoids having the user disarm then re-  
arm the system after allowing someone to enter or exit. The system will re-arm once the exit  
delay expires.  
Armed: Stay  
1. Select the Quick Exiticon to restart the exit  
delay.  
Note: Quick Exit is active in Away mode when : Auto  
Stay mode is enabled and no entry/exit zone  
Zones  
System  
has been faulted during the exit delay period.  
Disarm  
Quick Exit  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-060-V0  
22 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Entry/Exit Delays  
Exit Delay  
Exit delay begins immediately after arming the system, and gives you time to leave through  
the designated exit door without setting off an alarm. The system display will count down  
the time remaining in the exit delay, if programmed by your installer. If the system has been  
Armed Away, a slow beeping will sound throughout the exit delay period, if programmed by  
your installer. The exit door must be closed before the end of the exit delay. During the last  
10 seconds of the exit delay fast beeps will sound as a warning that the delay time is nearing  
its end. The exit beeps cannot be silenced.  
Restarting Exit Delay While System Armed  
Ask your installer if this feature is active for your system. If active, you can restart the exit  
delay one time after arming in Stay or Away mode during the exit delay by selecting the  
Restartkey. This will allowing extra time for someone to enter or exit or re-enter the  
property before the system is armed.  
Armed: Stay - Exit Now  
Exit now  
28 seconds  
Zones  
System  
Disarm  
Restart  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-061-V0  
Exit Alarms  
To minimize false alarms sent to the alarm monitoring company, your system may have been  
programmed for this feature. Ask your installer if Exit Alarm is active for your system.  
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is  
faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and  
starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm  
sound stops and the message Alarm Cancelled is displayed, in the system bar. Additionally,  
Alarm and the faulted zone are displayed with their associated icons in the system/zone  
status area. No message is sent to the alarm monitoring company. To clear the exit alarm  
condition, the open zone must be secured. To clear the display, select the Disarmicon OR  
depress the Offkey and then enter your security code.  
If you do not disarm the system before the entry delay ends, and an entry/exit door or  
interior zone is still open, the alarm sound continues and an "exit alarm" message is sent to  
the alarm monitoring company. The message Alarm Exit Error" is displayed, in the system  
bar. Additionally, Alarm and the faulted zone are displayed with their associated icons in the  
23 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Entry/Exit Delays  
system/zone status area. The alarm will continue to sound until the system is disarmed or  
timeout ocurs. To stop the alarm, the system must be disarmed by selecting the Disarm”  
icon OR depressing the Offkey and then entering your security code. The message Alarm  
Cancelled" is displayed, in the system bar, indicating that the alarm has been cancelled (if  
this feature is enabled by the installer). Alarmand the faulted zone continue to be  
displayed with their associated icons in the system/zone status area. To clear the display,  
select the Disarmicon OR depress the Offkey and then enter your security code a second  
time. An exit alarm also results if an entry/exit door or interior zone is faulted within two  
minutes after the end of the exit delay.  
Entry Delay  
Entry Delays give you time to disarm the system when you re-enter through the designated  
entrance door. You must disarm the system before the entry delay period ends, or an alarm  
will occur. The control beeps during the entry delay period, reminding you to disarm the  
system. There are two entry delays (if programmed). The first is for your primary entrance  
and the second can be used for a secondary entrance, where a longer delay is required to  
walk to the control to disarm the system. You can also arm the system with no entry delay at  
all by selecting the Delayicon prior to arming the system. This will toggle the system to  
Instant, which can provide greater security while on the premises or while away for  
extended periods of time. See ARMING THE SYSTEM section for procedure. See your  
installer for delay times programmed for your system.  
Exit Delay:  
None, 30, 45, 60, 90 seconds, 2 minutes  
None, 30, 45, 60, 90 seconds, 2 minutes  
None, 30, 45, 60, 90 seconds, 2 minutes  
Entry Delay 1:  
Entry Delay 2:  
LYNX Touch SIA Exit/Entry Delay Times  
Exit Delay:  
45, 60, 90 seconds, 2 minutes  
Entry Delay 1:  
Entry Delay 2:  
30, 45, 60, 90 seconds, 2, 3, 4 minutes  
30, 45, 60, 90 seconds, 2, 3, 4 minutes  
24 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Disarming the System  
Select the Disarmicon or the Offkey to disarm the system and to silence alarm and  
trouble sounds. See the SUMMARY OF AUDIBLE NOTIFICATION section for information,  
which will help you to distinguish between fire and burglary alarm sounds. During Entry  
Delay or when an Alarm Condition exists, the system will be disarmed as soon as the correct  
user code is entered on the touchscreen. Selecting the OFF key is not required. The entry  
beeps or alarm sound can be silenced by pressing any key however, it will restart in 10  
seconds if the correct User Code is not entered. The READY indicator will light (if no alarms  
have occurred while armed) and the control will beep once to confirm that the system is  
disarmed.  
**IMPORTANT**  
If the LYNX Touch is beeping rapidly upon entering the premises, an alarm has occurred  
during your absence and an intruder may still be on the premises. LEAVE IMMEDIATELY  
and CONTACT THE POLICE from a nearby safe location.  
Disarming the system and silencing alarms  
Armed: Stay  
1. Select the Disarmicon or depress the  
Offkey. The system will beep once and  
display a keypad.  
Zones  
System  
Disarm  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-056-V0  
Armed Stay  
1
2.  
Enter a valid Code. The system will beep  
once and announce Disarmed Ready to  
Arm.  
2
5
8
0
3
6
9
Note: If a valid user code is not entered or the  
Confirm icon has not been selected  
within 30 seconds, the system will return  
to the homescreen and it will not be  
disarmed.  
4
Enter Code:  
Cancel  
7
Clear  
5000-100-065-V0  
If an invalid User Code is entered, system will return to the home screen.  
25 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Disarming the System  
When an Alarm Occurs  
When an alarm has occurred, the touchscreen displays the zone number(s) that caused the  
alarm and the type of alarm (e.g., Fire Alarm). These messages remain displayed until  
cleared by a user. To clear the display, note the zone number displayed and enter an Off  
sequence. If the fault cannot be corrected, notify your alarm company.  
26 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Bypassing Protection Zones  
Bypassing Individual Zones  
The Bypass feature can be used when you want to intentionally arm your system with one or  
more zones unprotected. Bypassed zones are unprotected and will not cause an alarm when  
violated while your system is armed. All bypasses are removed when an Off sequence  
is performed. Bypasses are also removed if the arming procedure that follows the bypass  
command is not successful. The system will not allow panic, fire or CO zones to be  
bypassed.  
Bypassing zones  
Ready To Arm  
1. With the system in the disarmed state,  
select the Zonesicon. The system displays  
the Zones/Bypass screen.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Not Ready To Arm - Fault  
2. Select the zone(s) that you wish to bypass  
and then select BypassOR if programmed,  
the Bypass All Faultedbutton allows you to  
bypass all faulted zones (excluding Panic,  
Fire or CO zones). The system displays a  
keypad.  
2. Front  
Door  
FAULT  
Bypass All  
Faulted  
Clear  
Bypasses  
Select  
Bypass  
Fault  
5000-100-141-V0  
Not Ready to Arm - Fault  
3. Enter a valid Code. The system returns to  
the Bypass screen and the zone(s) that are  
bypassed will be displayed.  
Bypass Selected Zones  
1
4
7
2
5
8
0
3
6
9
Enter Code:  
4. Select the 2 icon to return to the home  
screen.  
5. Arm the system normally. See ARMING  
THE SYSTEM section for procedure  
Cancel  
Clear  
5000-100-067-V0  
27 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Bypassing Protection Zones  
Displaying Bypassed Zones  
Ready To Arm  
1. With the system in the disarmed state,  
select the Zonesicon. The system displays  
the Zone screen and the status for each  
zone will be indicated.  
Zones  
System  
2. Use the S” “Tbuttons to scroll to  
additional pages and view the zone status.  
3. If you select the Select Allbutton it  
functions scrolls through the following:  
Select All, Select Alarm, Select Trouble”  
and Select Fault. The system will display  
the associated zones.  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2. Front  
Door  
3. Garage  
Door  
BYPASSED  
READY  
READY  
96. Medical  
95. Fire  
READY  
99. Police  
READY  
Bypass All  
Faulted  
Clear  
Bypasses  
Select  
Bypass  
All  
5000-100-066-V0  
28 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Panic Keys  
Panic Keys  
Your system may have been programmed to use special keys to manually activate panic  
functions. The functions that might be programmed are listed below. See your installer for  
the function(s) that may have been programmed for your system.  
Note: Your installer should advise which functions are active in your system.  
Key  
Function  
When activated, alerts the alarm monitoring company that a fire condition exists.  
When activated, alerts the alarm monitoring company that a police emergency  
exists.  
When activated, alerts the alarm monitoring company that a health emergency  
exists.  
Types of Panic Alarms  
A silent emergency/silent alarm sends an alarm signal to the alarm monitoring  
company, if your system is connected to an alarm monitoring company, but there will be  
no audible alarms or visual displays.  
An audible emergency/audible alarm sends an emergency message to the alarm  
monitoring company, if your system is connected to an alarm monitoring company, and  
sounds a loud, steady alarm at your control. (ALARMwill be announced and the Alarm  
icon is displayed along with Alarmand Alarm 99 Policealternately.  
A personal emergency/aux alarm sends an emergency message to the alarm  
monitoring company, if your system is connected to an alarm monitoring company, and  
sounds at controls, but not at external sounders. . (ALARMwill be announced and the  
Alarm icon is displayed along with Alarmand with Alarm 96 Medical.  
A fire alarm sends a fire alarm message to the alarm monitoring company, if your  
system is connected to an alarm monitoring company, and uniquely activates the  
sounder. The Fire Alarm icon is displayed along with Fire Alarm 95 Fire.  
29 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Panic Keys  
Activating a panic alarm  
Ready To Arm  
1. With the system in the disarmed or armed  
state, depress and hold the Panickey until  
the system displays the Panic screen  
(approximately 3-4 seconds).  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2. Touch the desired panic icon on the screen.  
3. If applicable, the alarm will sound and the  
associated icon will be displayed.  
Police  
Fire  
Medical  
5000-100-068-V0  
Fire Alarm  
1
Note: Dependant upon how your system has  
been programmed a keypad may be  
displayed. This will allow you to cancel  
the alarm by entering valid User Code  
on the keypad.  
2
5
8
0
3
6
9
Fire Alarm  
Fire  
4
7
Enter Code:  
Cancel  
Clear  
5000-100-149-V0  
30 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Chime Mode  
Chime Mode  
Your system can be set to provide you with an audible alert of the opening of a door, while it  
is disarmed, by using Chime mode. When activated, three beeps will sound at the control  
whenever a protected perimeter door is opened and the zone voice descriptor will be  
announced. Additionally, the faulted zone information will be displayed on the home screen.  
Selecting the Zonesicon displays the open protection points. The Chime mode can be  
turned on only when the system is disarmed.  
Turning Chime mode On or Off  
Ready To Arm  
1. With the system in the disarmed or armed  
state, select the Settingsicon from the  
second page of the Home Screen. The  
system displays the Setting screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Select the Chimeicon. The system will  
toggle between Offand On. When Onis  
selected, the Chime mode will be active.  
Brightness  
3. Select the Savebutton to save your new  
Contrast  
Volume  
settings.  
Save  
Off  
Off  
Off  
Ringer  
Voice  
Chime  
5000-100-008-V0  
31 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECURING THE PREMISES  
Voice Mode  
Voice Mode  
Your system can be set to provide you with a voice alert of system functions by activating the  
Voice mode. When activated, the system will announce the system status when  
armed/disarmed. The Voice mode can be turned on only when the system is disarmed.  
Turning Voice mode On or Off  
Ready To Arm  
1. With the system in the disarmed or armed  
state, select the Settingsicon from the  
second page of the Home Screen. The  
system displays the Keypad screen.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2. Select the Voiceicon. The system will  
toggle between Offand On. When Onis  
selected, the Voice mode will be active.  
Brightness  
3. Select the Savebutton to save your new  
Contrast  
Volume  
settings.  
Save  
Off  
Off  
Off  
Ringer  
Voice  
Chime  
5000-100-008-V0  
32 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
User Access  
General Information  
For additional security you (the Master User Code) can assign secondary user codes to  
individual users enabling them to perform specific system functions. These secondary users  
are identified by "User Numbers" when their codes are assigned. You can assign up to 14  
user codes. Note that the Master User is the only one who can assign codes to secondary  
users.  
All codes can be used interchangeably when performing system functions (a system armed  
with one user's code can be disarmed by another user's code), with the exception of the  
Babysitter Code described below.  
Babysitter Code: This code can be used to arm the system, but cannot disarm the  
system unless the system was armed with this code. This code is typically assigned to  
someone (such as a babysitter) who needs to arm/disarm the system only at certain  
times.  
Duress Code: This feature is intended for use when you are forced to disarm or arm the  
system under threat. When used, the system will act normally, but can silently notify the  
alarm monitoring company of your situation, if that service has been provided. The  
Duress Code is useful only when the system is connected to an alarm  
monitoring company.  
IMPORTANT: Temporary users of the system (e.g., babysitters, cleaning staff) should not  
be shown how to use any system function they do not need to know, such as bypassing  
protection zones for example.  
False Alarm Prevention Feature  
The system prevents User Codes (including the Duress Code) from being duplicated. If you have  
attempted to assign a duplicate 4-digit code, the entry will be rejected. Any previous existing code will  
remain unchanged. Choose a different new 4-digit code and repeat the procedure.  
Adding a User  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
33 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
User Access  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
system displays the Master User  
programming screen.  
Program the system  
1
2
5
8
0
3
6
9
Enter Code:  
4
7
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Usersicon. The system displays  
the Master User screen.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
Ready To Arm  
4. Select the Add Newkey. The system  
displays a keyboard.  
Master ****  
Babysitter ****  
Note: **** appears to the right of User name after a  
valid 4-digit User Code has been assigned to a  
specific User.  
Duress ****  
Edit  
Add New  
Delete  
5000-100-069-V0  
Ready To Arm  
5. If desired you can enter a User Name.  
Select the Clearkey and then enter up to  
10 characters of text.  
Note: Select the ABC…” key to switch the keyboard  
between upper/lower case or the 123!@#key  
to switch to numbers.  
6. Once you are finished, select Done. The  
Clear  
abc...  
system displays the Keypad screen.  
Done  
5000-100-081-V0  
34 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
User Access  
Ready To Arm  
7. Enter the 4-digit code for the new User  
followed by Done. The system returns to  
the Users screen and the new User is  
displayed.  
Enter Code  
1
4
7
2
5
8
0
3
6
9
Clear  
Done  
5000-100-185-V0  
Ready To Arm  
Babysitter ****  
Master ****  
Duress ****  
Thomas ****  
Edit  
Add New  
Delete  
5000-100-142-V0  
Editing/Deleting a User  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
Program the system  
system  
displays  
the  
Master  
User  
1
4
7
2
3
6
9
programming screen.  
Enter Code:  
5
8
0
Cancel  
Clear  
5000-100-009-V0  
35 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
User Access  
Ready To Arm  
3. Select the Usersicon. The system displays  
the Users screen.  
Users  
Devices  
Events  
Schedules  
Reminders  
Test  
Date Time  
Slide Show  
Back  
5000-100-070-V0  
Ready To Arm  
4. Select a User Name and then select Edit”  
or Delete. If you are editing user  
information proceed to step 5. If you are  
deleting a user, proceed to step 8.  
Master ****  
Babysitter ****  
Thomas ****  
Duress ****  
Edit  
Add New  
Delete  
5000-100-142-V0  
Ready To Arm  
5. If desired you can revise a User Name.  
Select the Clearkey and then enter the  
desired text.  
6. Once you are finished, select Done. The  
system displays the Keypad screen. If your  
wish to change the assigned User Code,  
proceed to Step 7 otherwise proceed to Step  
9.  
Clear  
abc...  
Done  
5000-100-081-V0  
Ready To Arm  
7. If desired, enter a new 4-digit code for the  
selected User followed by Done. The  
system returns to the Users screen.  
Enter Code  
1
4
7
2
5
8
0
3
6
9
8. Select Yesor Nowhen the confirmation  
screen is displayed then proceed to step 9.  
9. Select the 2 icon to return to the Master  
User screen.  
Clear  
Done  
5000-100-185-V0  
36 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
View Events  
This feature can be used to view a number of System Events including Arming/Disarming,  
Zone Activity, Troubles and Alarms.  
Viewing System Events  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
system displays the Master User  
programming screen.  
Program the system  
1
4
7
2
5
8
0
3
6
9
Enter Code:  
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Eventsicon. The Events screen  
will appear and displays all events.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
37 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
View Events  
Ready To Arm  
4. If you wish to view specific system history,  
select All. The system displays a new  
menu.  
Sun Jun 13, 2010 15:08  
Disarmed  
User 2 E 441  
Sat Jun 12, 2010 11:15  
Armed Stay  
User 1 R 441  
Sat Jun 12, 2010 11:08  
Burglary Bypass  
Zone 3 E 570  
Sat Jun 12, 2010 10:15  
Disarmed  
User 1 E 401  
Fri Jun 11, 2010 18:08  
Armed Away  
User 2 R 401  
Fri Jun 11, 2010 12:10  
Disarmed  
User 3 E 441  
Fri Jun 11, 2010 11:08  
Armed Stay  
User 2 R 441  
Fri Jun 11, 2010 10:15  
Burglary Bypass  
Zone 3 E 570  
All  
5000-100-072-V0  
Ready To Arm  
5. Select from the menu to display the specific  
event types that you wish to view.  
All  
Alarm  
Note: Only the event types that were  
programmed by your installer are  
available for viewing.  
Trouble  
Bypass  
Open  
or Close  
Non  
Security  
5000-100-071-V0  
38 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Message Recording and Playback  
The LYNX Touch Message Center allows you to record, play and delete messages. The  
maximum message duration is 180 seconds.  
NOTES: (1) If the system loses electrical power, all messages will be erased.  
(2) Message Play/Record will not be available if a report must be sent.  
Entering message mode  
Ready To Arm  
1.  
With the system in the disarmed state,  
select the Messageicon from the Home  
Screen. The system displays the Message  
screen.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Recording a message  
Ready To Arm  
1. Select Add New. The system displays the  
Record Message screen.  
Add New  
Play  
Delete All  
Save  
5000-100-045-V0  
Ready To Arm  
2. Select Record, the system will sound a  
single tone. Speak into the microphone and  
record your message.  
Message 2  
Stopped  
3. When you are finished recording your  
message, select. Stop”  
4. To listen to the message, select Play.  
5. If you wish to delete the message, select  
Record  
Play  
Delete  
Delete.  
5000-100-047-V0  
39 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Message Recording and Playback  
Ready To Arm  
6. When you have finished recording, select  
2. The system displays the recorded  
messages.  
7. To record additional messages (if recording  
time is available) repeat steps 1 through 3.  
Message 1 2:48 PM September 1, 2010  
Message 2 5:09 PM September 5, 2010  
Add New  
Play  
Delete All  
5000-100-046-V0  
NOTE: If you are trying to record a new message and the message center is already full, Add Newwill not  
be displayed. If the message center is full all old messages must be deleted before new messages  
can be recorded. See Deleting Messages section.  
Playing a message(s)  
Ready To Arm  
1.  
2.  
3.  
At the Message screen, select the  
message you wish to play.  
Message 1 2:48 PM September 1, 2010  
Message 2 5:09 PM September 5, 2010  
Select Play, the system plays your  
message.  
When you are finished listening to the  
message, you may select. Stop. If Stop”  
is not selected the system continues to  
play the remaining messages.  
Add New  
Play  
Delete All  
5000-100-046-V0  
4.  
When you have finished listening to the  
messages, select 2. The system returns  
to the Home Screen.  
Deleting messages  
Ready To Arm  
1.  
2.  
At the Message screen, select Delete All.  
The system deletes all messages.  
Message 1 2:48 PM September 1, 2010  
Message 2 5:09 PM September 5, 2010  
When you have finished deleting the  
messages, select 2. The system returns  
to the Home Screen.  
Add New  
Play  
Delete All  
5000-100-046-V0  
40 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
System Adjustments  
The volume level of message playback, system announcements, and status beeps can be  
changed if desired. Additionally, you can adjust the displays brightness and contrast and  
turn on or off the Chime or turn off the telephone Ringer.  
Ready To Arm  
1. With the system in the disarmed or armed  
state, select the “Settings” icon from the  
second page of the Home Screen. The  
system displays the Settings screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Increase or decrease the Display Brightness  
or Contrast or the System Volume by using  
the sliding adjustment from left (decrease) to  
right (increase).  
Brightness  
Contrast  
Volume  
3. Turn On or Off the Voice, Chime or  
telephone  
Ringer  
by  
selecting  
the  
appropriate icon. The system toggles  
between Onand Off.  
Save  
Off  
Off  
Off  
Ringer  
Voice  
Chime  
4. Select Savewhen you are finished. The  
system returns to the second page of the  
Home Screen.  
5000-100-008-V0  
41 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Clock/Calendar  
Note: If your system is equipped with a GSMVLP5 or ILP5 Communication Module, the time and date will  
be programmed and updated automatically via Central Station. You may still program the correct  
Time Zone as shown below. Check with your installer to see if your system is equipped with a  
Communications Module.  
Setting the date and time  
Ready To Arm  
Note: The system must be disarmed in order  
to set the date and time.  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
Settings  
Back  
10:18 AM June 8, 2010  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
Program the system  
system  
displays  
the  
Master  
User  
1
4
7
2
5
8
0
3
6
9
programming screen.  
Enter Code:  
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Date Timeicon. The Calendar  
screen will appear.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
42 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Clock/Calendar  
System Programming...  
4. Select the correct month by using the W”  
and X.  
June  
2010  
SUN  
MON  
TUE  
WED  
THU  
FRI  
SAT  
5. Select the correct year by using the Wand  
X.  
1
2
3
4
5
6
8
9
10  
17  
24  
11  
18  
25  
12  
19  
26  
7
6. Select the correct day on the calendar.  
13  
14  
15  
16  
7. When you have finished select the Ticon.  
20  
27  
21  
28  
22  
29  
23  
30  
The system advances to the time screen.  
Save  
5000-100-016-V0  
System Programming  
8. If the displayed time is not correct, select  
Clearthen enter the correct time (4 digits)  
on the keypad and select AM or PM.  
1
2
5
8
0
3
6
9
Enter Time  
4
7
9. When you have finished select the Ticon.  
The system advances to the next screen OR  
proceed to step 17.  
10:21 AM  
AM / PM  
Clear  
Save  
5000-100-010-V0  
Ready To Arm  
10. Select Time Zone. The system scrolls  
Time Zone  
between through the following options:  
Eastern (EST)  
Eastern (EST)  
Central (CST)  
Mountain (MST)  
Pacific (PST)  
Hawaii (HAST)  
Alaska (AKST)  
Day Light Savings Time  
Yes  
Start Month  
Start Week  
March  
Second  
End Month  
End Week  
Save  
November  
First  
Select the correct time zone.  
5000-100-022-V0  
11. Select Day Light Savings Time. The  
system toggles between Yesand No.  
Note: The start month/week and end month week are  
default programmed to March/Secondand  
November/Firstrespectively. Steps 13 to 16  
should only be performed if you wish to change  
those entries. If you are not changing the  
defaults, advance to step 17.  
43 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Clock/Calendar  
Ready To Arm  
12. Select Start Month. The system displays a  
calendar. Select the correct month.  
January  
March  
May  
February  
April  
13. Select Start Week. The system will toggle  
between:  
Second  
Third  
June  
Fourth  
First  
July  
August  
5000-100-075-V0  
14. Select End Month. The system displays a  
calendar. Select the correct month.  
15. Select End Week. The system will toggle  
between:  
First  
Second  
Third  
Fourth  
16. When you are finished select the Save”  
key. The system returns to the Master User  
program screen.  
44 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Programming Devices  
General Information  
The Device programming option can be used to trigger device, send Follow-Me or E-mail  
messages of system events. Up to 16 devices can be programmed. Devices 1 through 8 are  
used for Triggers and Follow-Me Messages and Devices 9 through 16 are used for E-mail  
events. Check with your Installer to see which options are available to you.  
The following options are programmed in this section:  
Programming Field  
Device 1 -16:  
Name:  
Action  
Select Device 1 -16  
Name the device  
Action:  
Select the action required for the device  
Select Zone Type to trigger event  
Select Zone Type to stop event  
Select System Operation to trigger event  
Select System Operation to stop event  
Select Zone Number to trigger event upon fault, trouble or alarm  
as selected.  
Start Zone Type:  
Stop Zone Type:  
Start System Operation:  
Stop System Operation:  
Zone Number Operation:  
Programming Devices  
Ready To Arm  
1. With the system in the disarmed state, select  
the Toolsicon from the second page of the  
Home Screen. The system displays the Keypad  
screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
Program the system  
system displays the Master User programming  
screen.  
1
4
7
2
5
8
0
3
Enter Code:  
6
9
Cancel  
Clear  
5000-100-009-V0  
45 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Programming Devices  
Ready To Arm  
3. Select the Devicesicon. The system displays  
the Devices screen.  
Users  
Devices  
Events  
Schedules  
Reminders  
Test  
Date Time  
Slide Show  
Back  
5000-100-070-V0  
Ready To Arm  
4. Select a Devicekey followed by the Edit  
Device 1  
Device 2  
button. The system displays a keyboard.  
New  
New  
Device 3  
Device 4  
New  
New  
Device 5  
New  
Device 6  
New  
Edit  
Delete  
5000-100-187-V0  
Ready To Arm  
5. If desired you can enter a Device Name. Select  
the Clearkey and then enter up to 13  
characters of text.  
Note: Select the ABC…” key to switch the keyboard  
between upper/lower case or the 123!@#key to  
switch to numbers.  
Clear  
6. Once you are finished, select Done. The  
system returns to the Device screen.  
ABC...  
Done  
5000-100-190-V0  
Ready To Arm  
01  
7. Select the Typebutton. Dependant upon what  
features are programmed in your control the  
system toggles between the following options:  
Disabled  
Name  
Type  
Disabled  
Trigger Output  
Message to Phone 1  
Message to Phone 2  
Message to ph. 1&2  
Email 1  
Save  
5000-100-188-V0  
When an option is selected, the system displays  
several new programming fields.  
46 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Programming Devices  
Ready To Arm  
01  
8. Select Action. Dependant upon the Type  
selected previously, the system scrolls between  
Name  
Type  
several options:  
None  
Action  
Permanent On  
On for 2 sec  
Pulsing  
Trigger Output  
Start Zone Type  
None  
Stop Zone Type  
Not Used  
Not Used  
Send  
Start System Operation Stop System Operation  
Save  
9. Select Start Zone Type. The system displays  
Not Used  
Not Used  
the following options:  
Not Used  
Entry Exit 2  
5000-100-189-V0  
Entry Exit 1  
Perimeter  
Interior Follower  
24 Hour Silent  
Day/Night  
24 Hour Audible  
Use the S” “Tbuttons to scroll to second  
page of zone type options.  
Silent Burglary  
24 Hour Auxiliary  
Fire No Verification  
Trouble  
Interior With Delay  
Carbon Monoxide  
No Response  
Arm Stay  
Use the S” “Tbuttons to scroll to third page  
of zone type options.  
Arm Away  
Disarm  
Monitor  
Resident Response  
General Response  
Resident Monitor  
General Monitor  
10. Select Stop Zone Type. The system displays  
the same options as step 9.  
11. Select Start System Operation. The system  
displays the following options:  
Not Used  
Arm Away  
Arm Stay  
Disarm  
Any Burglary Alarm  
Bell Timeout  
Any Fire Alarm  
End of Exit Delay  
Use the S” “Tbuttons to scroll to second  
page of zone type options.  
Start of Entry Delay  
Kissoff  
System Low Battery  
Duress Alarm  
Chime  
Bypass  
Reporter Failure  
12. Select Stop System Operation. The system  
displays the same options as step 11.  
Use the S” “Tbuttons to scroll to second  
page of options.  
47 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Programming Devices  
Ready To Arm  
13. Select Zone Number Operation. The system  
Zone Number Operation  
Not Used  
toggles between the following options:  
None  
Trouble  
Fault  
Alarm  
If Trouble, Fault or Alarm is selected, the system  
displays several new options:  
Save  
5000-100-191-V0  
Ready To Arm  
14. Select a Start Zone or Stop Zone Number from  
the list displayed by the system.  
Zone Number Operation  
Fault  
15. Select Savewhen programming is complete.  
First Start Zone  
First Stop Zone  
Disabled  
Disabled  
Second Start Zone  
Second Stop Zone  
Disabled  
Disabled  
Third Start Zone  
Third Stop Zone  
Disabled  
Save  
Disabled  
5000-100-192-V0  
Editing or Deleting Devices  
Ready To Arm  
1. At the Device Programming Screen, select the  
Device that you wish to edit or delete.  
Device 1  
System Armed  
Follow Me  
Device 2  
New  
2. To delete the device, select the delete button.  
To edit the device select the Edit button and  
proceed to step 3.  
Device 3  
New  
Device 4  
New  
Device 5  
New  
Device 6  
New  
Edit  
Delete  
5000-100-194-V0  
Ready To Arm  
3. Select the field that you wish to edit and follow  
the steps as outlined in the Programming  
Devices procedure.  
Name  
System Armed  
Type  
01  
Action  
Message to phone 1  
Start Zone Type  
Send  
Stop Zone Type  
Not Used  
Not Used  
Start System Operation Stop System Operation  
Save  
Armed Stay  
Disarm  
5000-100-195-V0  
48 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Scheduling User Interface  
The Scheduling Feature can be used to program the system to automatically perform certain  
functions (i.e.; automatically arming the system in Stay mode and activating output devices).  
Programming a Scheduled Function  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
system displays the Master User  
programming screen.  
Program the system  
1
4
7
2
5
8
0
3
6
9
Enter Code:  
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Schedulesicon. The system  
displays the Scheduling screen.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
49 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Scheduling User Interface  
Ready To Arm  
4. Select Add New. The system displays the  
scheduling options screen.  
Edit  
Add New  
Delete  
5000-100-146-V0  
Ready To Arm  
5. Select Name. The system displays a  
Name  
Frequency  
keypad.  
None  
Type  
None  
Save  
5000-100-144-V0  
Ready To Arm  
6. Enter a name (up to 13 digits long) for the  
scheduled function on the displayed keypad  
then select Done.  
7. Select Frequencythen select one of the  
following displayed options:  
None  
Daily  
Weekly  
Once  
Weekday  
Monthly  
Clear  
abc...  
Done  
5000-100-081-V0  
8. Program the following options based upon  
the Frequency selected in step 7:  
Once  
Date  
Daily  
Weekday Start Time  
Weekly  
Monthly  
Day of the Week  
Day of the Month  
9. Select Typethen scroll through and select  
one of the following options:  
None  
Auto Stay  
Output  
Disarm Notification  
50 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Scheduling User Interface  
Ready To Arm  
10. If Auto Stay is selected, select Clearthen  
enter a 4-digit time on the displayed keypad  
then select Save. If Outputis selected  
proceed to Step 11. If Disarm Notification”  
is selected proceed to Step 12.  
1
4
7
2
5
8
0
3
6
9
Enter Time  
10:21 AM  
11. Select a Device (Device 1 through Device  
16).  
AM / PM  
Clear  
Done  
12. Enter a Start Time and End Time on the  
displayed keypad then select Save.  
5000-100-147-V0  
Editing a Scheduled Function  
Ready To Arm  
1. At the Schedules screen, select the  
Schedule you wish to edit.  
Auto Arm  
-Auto Stay  
-Daily  
2. Select the Editbutton. The Schedule  
programming screen will appear. Follow the  
steps as noted above in the programming a  
Scheduled Function section to edit and  
save your changes.  
Edit  
Add New  
Delete  
5000-100-179-V0  
Deleting a Scheduled Function  
Ready To Arm  
1. At the Schedules screen, select the  
Schedule you wish to delete.  
Auto Arm  
-Auto Stay  
-Daily  
2. Select the Deletebutton. A confirmation  
screen will be displayed. Select Yesto  
confirm the deletion.  
3. Select the 2button. The system returns  
to the Master User programming screen.  
Edit  
Add New  
Delete  
5000-100-179-V0  
51 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Reminders  
The Reminder Feature can be used to program/record reminders that can be displayed on the  
touchscreen, announced by the control and/or sent to one ort two pre-programmed phone  
number(s). Check with your installer to see if the latter feature has been programmed on  
your control.  
Programming a Reminder  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
system displays the Master User  
programming screen.  
Program the system  
1
4
7
2
5
8
0
3
6
9
Enter Code:  
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Remindersicon. The system  
displays the Reminders screen.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
52 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Reminders  
Ready To Arm  
4. Select Add New. The system displays the  
Reminder programming screen.  
No items to display!  
Edit  
Add New  
Delete  
5000-100-178-V0  
Ready To Arm  
5. Select Name. Enter a name for the  
scheduled function on the displayed keypad  
then select Done.  
Name  
Frequency  
None  
6. Select Frequencythen select one of the  
following displayed options:  
None  
Once  
Daily  
Weekly  
Weekday  
Monthly  
Voice  
No  
Acknowledge  
Save  
No  
5000-100-176-V0  
7. Program the following options based upon  
the Frequency selected in step 6:  
Ready To Arm  
Once  
Daily  
Date/Start Time  
Start Time  
Weekday Start Time  
Weekly  
Monthly  
Days of the Week/Start Time  
Day of the Month/Start Time  
Clear  
abc...  
Done  
5000-100-180-V0  
Ready To Arm  
8. If a voice reminder is desired, select  
Voice. The system toggles between No”  
and Yes. If yes is selected, the record  
reminders screen appears.  
Reminders 1  
Stopped  
9. Select the Recordbutton and record your  
reminder. When you are finished select the  
Stopbutton followed by the 2button.  
The system returns to the Reminder  
programming screen.  
Record  
Play  
Delete  
5000-100-182-V0  
53 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Reminders  
Ready To Arm  
10. If a Follow Mephone number(s) was  
programmed by your installer you can send  
a reminder to the phone number(s). Select  
Follow Meoption. The system toggles  
between Disabled, To Ph. 1, To Ph. 2”  
and To Ph. 1 & 2, as applicable.  
Name  
Walk Dog  
Frequency  
Once  
Date  
January 1, 2011  
Start Time  
3:00 PM  
Note: For important reminders you should  
program the Acknowledgeoption.  
When this option is selected, the  
reminder will continue to play until it is  
acknowledged.  
Voice  
No  
Follow Me  
Disabled  
Acknowledge  
Save  
No  
5000-100-183-V0  
11. Select the Acknowledgeoption. The  
system toggles between No and Yes.  
12. Select Savewhen all applicable options  
have been programmed.  
Editing a Reminder  
Ready To Arm  
1. At the Reminders screen, select the  
reminder you wish to edit.  
Walk Dog  
- Daily  
2. Select the Editbutton. The Reminder  
programming screen will appear. Follow the  
steps as noted above in the programming a  
Reminder section to edit and save your  
changes.  
Edit  
New  
Delete  
5000-100-184-V0  
Deleting a Reminder  
Ready To Arm  
1. At the Reminders screen, select the  
reminder you wish to delete.  
Walk Dog  
- Daily  
2. Select the Deletebutton. A confirmation  
screen will be displayed. Select Yesto  
confirm the deletion.  
3. Select the 2button. The system returns  
to the Master User programming screen.  
Edit  
New  
Delete  
5000-100-184-V0  
54 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Speaker Phone Feature  
If this feature has been programmed the LYNX Touch is capable of operating as a speaker  
phone. During speaker phone operation the system will provide the following functions:  
All function/event processing will continue to operate, but there will be no  
announcements.  
NOTE: The system will enter the Speaker Phone mode even if an alarm or trouble is stored in the system  
memory.  
Do not use the speaker phone as the only telephone in your home since in some special  
cases the speaker phone is not functional.  
The system will not enter speaker phone mode and LYNX Touch will not ring if:  
The feature has not been programmed.  
A report is being sent.  
An audible alarm is present.  
An announcement is being made or a recorded message is being played back.  
A message is being recorded.  
If the system is in test or sniffer mode.  
AC power is not present  
The speaker phone will be aborted if:  
A report must be sent.  
An audible alarm or trouble has ocurred.  
AC power is lost.  
Using the Speaker Phone Feature  
When the LYNX Touch is operating in the Speaker Phone mode, if a zone is violated and has  
triggered an entry/exit delay, the system will automatically change the touchscreen from  
telephone to security mode. This allows the user to disarm the system or take other  
appropriate actions in the security mode without interrupting the telephone session. To  
regain telephone keypad control you will need to reactivate the telephone keypad.  
55 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Speaker Phone Feature  
Placing a Call  
Ready To Arm  
1. With the system in the disarmed or armed  
state, select the Phoneicon from the  
Home Screen. The system displays the  
Keypad screen.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
Phone  
More  
Message  
10:18 AM June 8, 2010  
5000-100-006-V0  
Ready To Arm  
2. Select the Talkicon and then enter the  
number you wish to dial. The Endicon  
replaces the Talkicon. Selecting the  
Redialicon will allow you to redial the last  
number that was dialed.  
1
4
7
2
5
8
0
3
6
9
Talk  
3. Select the Flashicon to switch between  
Flash  
two calls.  
Redial  
Volume  
4. Select the Endicon to hang up and end  
the call.  
5000-100-148-V0  
Answering a Call  
Ready To Arm  
1. With the system in the disarmed or armed  
state, select the Phoneicon from the  
Home Screen. The system displays the  
Keypad screen.  
Zones  
System  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Phone  
Message  
More  
5000-100-006-V0  
Ready To Arm  
2. Select the Talkicon. The Endicon  
replaces the Talkicon.  
1
4
7
2
5
8
0
3
6
9
3. Select the Endicon to hang up and end  
the call.  
Talk  
Flash  
Redial  
Volume  
5000-100-148-V0  
56 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Remote Phone Control Feature  
The LYNX Touch Series is equipped with a remote interactive phone capability that permits  
access to the security system from any off-site touch-tone telephone using all user codes. The  
system will provide the appropriate voice messages and any system beeping sounds  
indicating the status of the security system over the phone line. (Refer to Summary of  
Audible Notification for further information.) The following functions can be performed from  
any remote touch-tone telephone:  
Disarm the system.  
Arm the system in STAY or AWAY mode.  
Bypass zones.  
Check system status.  
The remote access session will be aborted if:  
A report must be sent.  
Any local or wireless key entry is made.  
User Code is not entered within eight (8) seconds of call pickup (during the  
system..system announcement).  
No keys are depressed for a period of 15 seconds and while no announcement has been  
made by the system. Any remote key entry will, however extend this timeout back to 15  
seconds.  
It will not be possible to begin a remote access session if:  
A report must be sent  
The system is in any Test mode.  
Panel is in shutdown mode (programmed by your installer).  
Using Remote Phone Control Feature  
Dial the controlss phone number. If no answering machine is present, the control will pick  
up between 1 and 14 rings, depending on the number programmed by your installer and will  
periodically announce SYSTEM ENTER CODE. If an answering machine is on the  
premises, you need to dial the premises and hang up on the first ring. Wait at least five (5)  
seconds (but no more than 22 seconds) and dial the premises phone number again. The  
control will pick up and periodically announce SYSTEM.  
57 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Remote Phone Control Feature  
Remote Phone Control Commands  
Enter User Code (within eight seconds). Upon entering remote phone control mode the Lynx will  
announce System, enter code.  
To remotely disarm system:...........................................................User Code + [1]  
To remotely arm in AWAY mode: ..................................................User Code + [2]  
To remotely arm in STAY mode: ...................................................User Code + [3]  
To remotely arm in AWAY or STAY mode with no delay:..............User Code + [2] or [3] + [0]  
To remotely Bypass zones: ...........................................................User Code + [6] + zone no.  
To remotely activate Forced Bypass: ............................................User Code + [6] + [#]  
To remotely check system status:..................................................[]  
To end remote phone session: Hang Up or .................................User Code + [9]  
Notes: (1) Check with your installer to see if the Forced Bypass mode has been enabled.  
(2) When bypassing zones, make sure a confirmation beep sounds for each zone that has been  
bypassed.  
58 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USER FUNCTIONS  
Remote Services  
Your security system may be capable of providing a series of web-based services that allow  
you to communicate with your security system remotely in a number of ways. These services  
provide the ability to:  
Access to your security system from a computer via website (Remote Access Feature)  
Receive e-mail and text message notification of system events (Multi-Mode Feature)  
Perform system functions and receive confirmations using text messages (SMS  
Feature)  
Ask you installer if your system employs a remote services capable device.  
59 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIRE/CO ALARM SYSTEM (If Installed)  
General Information  
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour  
backup battery (P/N LYNXRCHKIT-SHA) is installed.  
UL  
General  
Your fire alarm system (if installed) is active 24 hours a day, providing continuous  
protection. In the event of an emergency, the installed smoke, heat and/or carbon monoxide  
detectors will automatically activate your security system, triggering a loud, intermittent  
sound from the touchscreen. The sound will be interlaced with the voice descriptor, sounding  
every 15 seconds. A FIREor COmessage will appear at your touchscreen and remain on  
until you silence and clear the alarm display.  
In Case of Fire  
1. Should you become aware of a fire emergency before your detectors sense the problem, go  
to the LYNX Touch and press and hold the panic key and then select the Fire icon. The alarm  
will sound and an alarm will be transmitted to the central station.  
2. Evacuate all occupants from the premises.  
3. If flames and/or smoke are present, leave the premises and notify your local Fire Department  
immediately.  
4. If no flames or smoke are apparent, investigate the cause of the alarm. The zone number of  
the zone(s) in an alarm condition will appear at the touchscreen.  
In Case of Carbon Monoxide Alarm  
1. If a high level of carbon monoxide is detected you should evacuate all occupants from the  
premises and immediately move to a spot where fresh air is available, preferably outdoors.  
2. From a safe area, contact your security service provider for further instructions.  
Silencing a Fire/Carbon Monoxide Alarm  
1. Silence the alarm by entering an OFF sequence.  
2. To clear the alarm, enter a second OFF sequence.  
3
If the touchscreen indicates a trouble condition after the second OFF sequence, check that  
smoke detectors are not responding to smoke- or heat-producing objects in their vicinity.  
Should this be the case, eliminate the source of heat or smoke.  
4. If this does not remedy the problem, there may still be smoke in the detector. Clear it by  
fanning the detector for about 30 seconds.  
5. When the problem has been corrected, clear the display by entering another OFF sequence.  
60 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIRE/CO ALARM SYSTEM  
National Fire Protection Association’s  
Smoke Detector Recommendations  
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour  
backup battery (P/N LYNXRCHKIT-SHA) is installed.  
UL  
With regard to the number and placement of smoke and heat detectors, we subscribe to the  
recommendations contained in the National Fire Protection Association's (NFPA) Standard  
#72 noted below.  
Early warning fire detection is best achieved by the installation of fire detection equipment  
in all rooms and areas of the household. The equipment should be installed as follows: A  
smoke detector installed outside of each separate sleeping area, in the immediate vicinity of  
the bedrooms and on each additional story of the family living unit, including basements and  
excluding crawl spaces and unfinished attics.  
In addition, the NFPA recommends that you install heat or smoke detectors in the living  
room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage  
rooms, basements and attached garages.  
KITCHEN  
KITCHEN  
LIVING ROOM  
BDRM  
DINING  
BEDROOM  
BEDROOM  
TV ROOM  
DINING  
BDRM  
BEDROOM  
BEDROOM  
LIVING ROOM  
Smoke Detectors for Minimum Protection  
Smoke Detectors for Additional Protection  
Heat-Activated Detectors  
BEDROOM  
TO  
BR  
BEDROOM  
BEDROOM  
KTCHN  
GARAGE  
CLOSED  
DOOR  
LVNG RM  
.
BASEMENT  
floor_plan-001-V1  
61 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIRE/CO ALARM SYSTEM  
Emergency Evacuation  
LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour  
backup battery (P/N LYNXRCHKIT-SHA) is installed.  
UL  
Establish and regularly practice a plan of escape in the event of fire. The following steps are  
recommended by the National Fire Protection Association:  
1. Position your detector or your interior and/or exterior  
sounders so that they can be heard by all occupants.  
2. Determine two means of escape from each room. One  
path of escape should lead to the door that permits  
normal exit from the building. The other should be an  
alternative escape, such as a window, should your path  
to that door be unpassable. Station an escape ladder at  
such windows if there is a long drop to the ground.  
3. Sketch a floor plan of the building. Show windows, doors,  
ND  
2
FLOOR  
stairs and rooftops that can be used to escape. Indicate  
escape routes for each room. Keep these routes free from  
obstruction and post copies of the escape routes in every  
room.  
BACK DOOR  
4. Assure that all bedroom doors are shut while you are  
asleep. This will prevent deadly smoke from entering  
while you escape.  
1ST FLOOR  
5. Try the door. If the door is hot, check your alternate  
escape route. If the door is cool, open it cautiously. Be  
prepared to slam the door if smoke or heat rushes in.  
6. When smoke is present, crawl on the ground. Do not  
walk upright, since smoke rises and may overcome you.  
Clearer air is near the floor.  
BACK  
7. Escape quickly; don't panic.  
8. Establish a place outdoors, away from your house, where  
everyone can meet and then take steps to contact the  
authorities and account for those missing. Choose  
someone to assure that nobody returns to the house —  
many die going back.  
FRONT  
emerevac  
62 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM FUNCTIONS  
Testing the System (to be conducted weekly)  
Test Mode  
The Test mode allows each protection point to be checked for proper operation. When the  
Walk Test mode is active, the control sounds a single beep every 30 seconds as a reminder  
that the system is in the Test mode.  
NOTE: An alarm message will not be sent to your alarm monitoring company during these tests.  
Entering Test Mode  
Disarm the system and close all protected windows, doors, etc. The READYindicator  
should be lit.  
Testing the System  
Ready To Arm  
1. With the system in the disarmed state,  
select the Toolsicon from the second page  
of the Home Screen. The system displays  
the Keypad screen.  
Tools  
Arm Away  
Delay  
Arm Stay  
10:18 AM June 8, 2010  
Settings  
Back  
5000-100-007-V0  
Ready To Arm  
2. Enter your 4-digit Master User Code. The  
system displays the Master User  
programming screen.  
Program the system  
1
4
7
2
5
8
0
3
6
9
Enter Code:  
Cancel  
Clear  
5000-100-009-V0  
Ready To Arm  
3. Select the Testicon. The system displays  
the Test screen.  
Users  
Devices  
Schedules  
Reminders  
Test  
Date Time  
Events  
Slide Show  
Back  
5000-100-070-V0  
63 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM FUNCTIONS  
Testing the System (to be conducted weekly)  
Ready To Arm  
4. Select the Walk Testor Dialer Testicon.  
If Walk Test is selected proceed to Step 5. If  
Dialer Test is selected proceed to Step 6  
Version Number: CA01.00EXX  
CRC Number: 0X877D  
RF Version Number: 0.44  
5. Walk Test…” is displayed on the system  
status bar. Fault each zone as described  
below.  
6. If the dialer test is unsuccessful the system  
will display a Reporter Failure message.  
Contact your security service provider.  
Walk Test  
Dialer Test  
Back  
5000-100-076-V0  
Walk Test  
FAULT ZONES. Open each protected door and window in turn and listen for three beeps  
from the control, followed by the zones Voice Descriptor, if it is programmed. Identification  
of each faulted protection point should appear on the display. The display will clear when the  
door or window is closed.  
Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice  
descriptors, if programmed. The identification of the detector should appear on the display  
when it is activated, and its voice descriptor will be announced (if programmed). The display  
will clear when no motion is detected. Note that if wireless motion detectors are used, in  
order to conserve battery life, there is a 3-minute delay between activations.  
To test all smoke detectors, follow the manufacturer's instructions. The identification of each  
detector should appear on the display when each is activated.  
If a problem is experienced with any protection point (no confirming sounds, no display),  
notify your service company.  
When all protection points have been checked and are intact (closed), there should be no zone  
identification numbers displayed on the touchscreen.  
Exiting Test Mode  
When testing is completed, exit the Walk Test or Dialer Test mode by entering an Off  
sequence.  
NOTE: If the Walk Test mode is inadvertently left active, it automatically turns off after 4 hours. The Dialer  
Test mode will remain active until exited via an Off sequence.  
LYNX Touch SIA Exit/Entry Delay Times  
The LYNX Touch SIA will send an event code to the Central Station after entering and after  
exiting from Test mode.  
64 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM FUNCTIONS  
Maintaining your system  
The components of your security system are designed to be as maintenance-free as possible.  
To make sure that your system is in working condition, do the following:  
1. Test your system weekly.  
2. Test your system after any alarm occurs (see the TESTING THE SYSTEM section).  
Routine Care  
Treat the components of your security system as you would any other electrical  
equipment. Do not slam sensor-protected doors or windows.  
Keep dust from accumulating on the touchscreen and all protective sensors, particularly  
on motion sensors and smoke detectors.  
The touchscreen and sensors should be cleaned carefully with a dry soft cloth. Do not  
spray water or any other fluid on the units.  
Low Battery Conditions in Wireless Sensors  
Each wireless sensor in your system has an internal battery. The system detects low battery  
conditions in wireless sensors, including smoke detectors, personal emergency transmitter,  
and the portable wireless keypad, and displays a Battery Lowmessage on the touchscreen,  
which also beeps. A low battery in a wireless keypad is detected as soon as one of its keys is  
pressed. In addition, a wireless smoke detector with a low battery also emits a "chirp" sound  
approximately once every 2030 seconds, identifying itself as the smoke detector with the  
weak battery.  
NOTE: A low battery message means that battery replacement in the indicated sensor(s) is due within 30  
days. In the meantime, a sensor with a low battery is still operational.  
To silence Low Battery Warning Tones, enter an Off sequence. The low battery message  
display will remain on as a reminder. When you replace the weak battery with a fresh one,  
the sensor will send a "good battery" signal to the control when the sensor is activated  
(opening/closing of door, window, etc.). To clear the Low Batterymessage, enter an Off  
sequence.  
When replacing batteries, use only those recommended by your installer.  
Alkaline batteries provide a minimum of 1 year of operation, and in most units and applications, provide 24  
years of service. 3-volt lithium batteries may provide from 4-7 years of operation. Actual battery life will  
depend on the environment in which the sensor is used, the number of signals that the transmitter in the  
sensor has had to send, and the specific type of sensor. Factors such as humidity, high or low temperatures,  
and large swings in temperature may all lead to the reduction of actual battery life in an installation.  
65 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM FUNCTIONS  
Maintaining your system  
Changing the LYNX Touch Series System Battery  
In the event of an AC power loss, the LYNX Touch Series is powered by a rechargeable,  
nickel-metal hydride battery pack. The battery pack should be replaced when a Battery  
Lowmessage with no zone number is displayed.  
NOTE: The battery pack (P/N LYNXRCHKIT-SC or LYNXRCHKIT-SHA) should be changed every four years  
and must be replaced by a qualified service technician.  
Following battery pack replacement, rechargeable batteries may take up to 48 hours to  
charge. The Battery Lowmessage may be displayed after one minute, however it should  
clear within 4 hours or by entering Test Mode.  
66 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS  
SOUND  
CAUSE  
ANNOUNCEMENT*  
INTERRUPTED  
FIRE ALARM (3 beeps)  
OR  
fire alarm + zone voice descriptor  
OR  
CARBON MONOXIDE ALARM (4 beeps)  
Carbon monoxide alarm + zone voice descriptor  
(Voice descriptor is interlaced with the sounder  
and sounds every 45 seconds)  
alarm + zone voice descriptor  
(Voice descriptor is interlaced with the sounder  
and sounds every 45 seconds)  
a. disarmed–ready to arm  
CONTINUOUS  
BURGLARY/AUDIBLE EMERGENCY  
ALARM  
ONE SHORT BEEP  
(not repeated)  
a. SYSTEM DISARM  
b. SYSTEM ARMING ATTEMPT WITH AN  
OPEN ZONE.  
b.disarmed–not ready to arm  
c. BYPASS VERIFY  
c. zones bypassed  
ONE SHORT BEEP  
(once every 45 secs) b. LOW BATTERY AT A TRANSMITTER  
c. SYSTEM LOW BATTERY  
a. SYSTEM IS IN TEST MODE  
a. no announcement  
b.low battery + zone voice descriptor  
c. system low battery  
d. FAIL TO COMMUNICATE  
d.check system  
TWO SHORT  
BEEPS  
ARM AWAY  
armed away [instant] – exit now  
THREE SHORT  
BEEPS  
a. ARM STAY OR INSTANT  
b. ZONE OPENED WHILE SYSTEM IS IN  
CHIME MODE.  
a. armed stay [instant] – exit now  
b.zone voice descriptor  
RAPID BEEPING  
SLOW BEEPING  
a. TROUBLE  
a. fault + zone voice descriptor  
b.fire alarm or alarm + zone voice descriptor  
a. disarm system now  
b. MEMORY OF ALARM  
a. ENTRY DELAY WARNING  
b. EXIT DELAY WARNING  
b.armed [away] [instant] – exit now  
Additional Announcements:  
The system will announce the following primary messages, depending on the systems status  
at the time:  
DisarmedReady to Arm [check system]  
Disarmed [not ready to arm]  
Armed [away] [stay] [instant] [check system] [exit now]  
The system will announce the following secondary messages, depending on the systems  
status at the time:  
Fire Alarm + zone voice descriptor  
Alarm + zone voice descriptor  
Carbon Monoxide Alarm + zone voice descriptor  
Carbon Monoxide Fault + zone voice descriptor  
Fire Fault + zone voice descriptor  
Fault + zone voice descriptor Alarm + zone voice descriptor  
Low Battery + zone voice descriptor Fire Fault + zone voice descriptor  
System Low Battery  
Check System  
AC Loss  
Zones Bypassed  
Chime  
Note: If there are no secondary messages, the primary status messages will be announced.  
67 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS  
System Displays  
The following icons will be displayed on the Home screen along with specific zone status  
information (if applicable) to indicate system status.  
DISPLAY  
DEFINITION  
DISPLAY  
DEFINITION  
AC Loss  
Door Open  
Alarm  
Window Open  
(intrusion)  
Armed Away  
Armed Stay  
Exit Active  
Fire  
Battery Low  
Flood  
Check Zones  
CO Alarm  
Glass Break  
Medical Alarm  
Disarmed Not  
Ready to Arm  
Motion  
Disarmed  
Ready to Arm  
Temperature  
90 RF Jam  
Reporter  
Failure  
Cover  
Tamper  
94 Phone  
Line Cut  
Trouble  
103 Comm.  
Trouble  
68 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SUMMARY OF AUDIBLE & VISUAL NOTIFICATIONS  
Zone Status Icons  
The following icons may be displayed on the Zone Status screen.  
DEFINITION  
Alarm  
DEFINITION  
ICON  
ICON  
Trouble (red)  
Fault (Yellow)  
Ready  
Bypass  
LED Meanings  
ARMED LED (Red):  
ON = System armed  
OFF = System disarmed  
Blinking = System armed, but a fault exists or alternating with READY LED  
when AVM (VOX or Talk) or speaker phone mode is active.  
READY LED (Green): ON = System disarmed, ready to arm  
Blinking = System disarmed, not ready to arm (a fault exists) or alternating  
with ARMED LED when AVM (VOX or Talk) or speakerphone mode is active.  
Note: When the system is armed, the READY LED turns off.  
69 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Agency Statements  
Federal Communications Commission (FCC) Part 15  
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's  
Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment.  
CLASS B DIGITAL DEVICE STATEMENT  
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the  
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not  
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be  
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the  
following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
This Class B digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  
Industry Canada (IC)  
This device complies with RSS210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may  
not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause  
undesired operation.  
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est  
soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute  
interference reçue y compris les interferences causant une reception indésirable.  
70 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Agency Statements  
TELEPHONE/MODEM INTERFACE  
Federal Communications Commission (FCC) Part 68  
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains the FCC  
registration number and Ringer Equivalence Number (REN). You must provide this information to the telephone company when  
requested.  
This equipment uses the following USOC jack: RJ31X  
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is subject to state tariffs.  
This equipment is hearing-aid compatible.  
Industry Canada  
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment meets  
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment  
Technical Requirements document(s). The Department does not guarantee the equipment will operate to the users satisfaction.  
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local  
telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer  
should be aware that compliance with the above conditions may not prevent degradation of service in some situations.  
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations  
made by the user to this equipment, or equipment malfunctions, may give the telecommunications company to request the user to  
disconnect the equipment.  
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal  
metallic water pipe system, if present, are connected together, This precaution may be particularly important in rural areas.  
Caution: Users should not attempt to make such connections themselves but should contact appropriate electric inspection  
authority, or electrician, as appropriate.  
AVIS: l’étiquette dIndustrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux  
normes de protection, dexploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents  
concernant les exigences techniques relatives au matériel terminal. Le Ministère nassure toutefois pas que le matériel  
fonctionnera à la satisfaction de lutilisateur.  
Avant dinstaller ce matériel, lutilisateur doit sassurer quil est permis de le raccorder aux installations de lenterprise locale de  
télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da raccordement. Labonné ne doit  
pas oublier quil est possible que la conformité aux conditions énoncées ci-dessus nempêche pas la dégradation du service dans  
certaines situations.  
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur. Lentreprise de  
télécommunications peut demander à lutilisateur da débrancher un appareil à la suite de réparations ou de modifications  
effectuées par lutilisateur ou à cause de mauvais fonctionnement.  
Pour sa propre protection, lutilisateur doit sassurer que tous les fils de mise à la terre de la source denergie électrique, de lignes  
téléphoniques et des canalisations deau métalliques, sil y en a, sont raccordés ensemble. Cette précaution est particulièrement  
importante dans les régions rurales.  
Avertissement : Lutilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un service  
dinspection des installations électriques, ou à un électricien, selon le cas.  
Ringer Equivalence Number Notice:  
The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of  
terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of  
devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5.  
AVIS : Lindice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de  
terminaux qui peuvent être raccordés à une interface. La terminaison dune interface téléphonique peut consister en une  
combinaison de quelques dispositifs, à la seule condition que la somme dindices d’équivalence de la sonnerie de tous les  
dispositifs nexcède pas 5.  
RF Exposure  
WARNING: The LYNX Touch must be installed to provide a separation distance of at least 7.8 in (20 cm) from  
all persons and not co-located or operated in conjunction with any other transmitter.  
71 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS  
In the event of telephone operational problems, disconnect the control by removing the plug from the  
RJ31X (CA38A in Canada) telephone wall jack. We recommend that your certified installer  
demonstrate disconnecting the phones on installation of the system. Do not disconnect the phone  
connection inside the control/communicator. Doing so will result in the loss of your phone lines. If the  
regular phone works correctly after the control/communicator has been disconnected from the phone  
lines, the control/communicator has a problem and should be returned for repair. If upon disconnection  
of the control/communicator, there is still a problem on the line, notify the telephone company that they  
have a problem and request prompt repair service. The user may not under any circumstances (in or  
out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an  
authorized service agency for all repairs.  
72 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER'S INSURANCE PREMIUM CREDIT REQUEST  
This form should be completed and forwarded to your homeowner's insurance carrier for possible premium credit.  
A. GENERAL INFORMATION:  
Insured's Name and Address:  
Insurance Company:  
Policy No.:  
LYNX Touch Series _________________________________________________  
Other  
Both  
Type of Alarm:  
Installed by:  
Burglary  
Fire  
Serviced by:  
Name  
Address  
B. NOTIFIES (Insert B = Burglary, F = Fire)  
Name  
Address  
Local Sounding Device  
Police Dept.  
Fire Dept.  
Central Station  
Name: _______________________________________________________________________________  
Address:  
Phone:  
C. POWERED BY: A.C. With Rechargeable Power Supply  
D. TESTING: Quarterly Monthly  
Weekly  
Other  
(continued on other side)  
73 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OWNER'S INSURANCE PREMIUM CREDIT REQUEST (cont.)  
E. SMOKE DETECTOR LOCATIONS  
Furnace Room  
Kitchen  
Bedrooms  
Attic  
Hall  
Basement  
Living Room  
Dining Room  
F. BURGLARY DETECTING DEVICE LOCATIONS:  
Front Door  
Basement Door  
Rear Door  
All Exterior Doors  
1st Floor Windows  
All Windows  
Interior Locations  
All Accessible Openings, Including Skylights, Air Conditioners and Vents  
G. ADDITIONAL PERTINENT INFORMATION:  
Signature:  
Date:  
74 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SERVICING INFORMATION  
Your local Honeywell dealer is the person best qualified to service your alarm  
system. Arranging some kind of regular service program with him is  
advisable.  
Your local Honeywell dealer is:  
Name:  
Address:  
Phone:  
75 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARNING!  
THE LIMITATIONS OF THIS ALARM SYSTEM  
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other  
emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of  
reasons. For example:  
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or  
disconnect an alarm warning device.  
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without  
power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly.  
Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.  
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the  
signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.  
A user may not be able to reach a panic or emergency button quickly enough.  
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or  
provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal  
Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are  
as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start  
where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke  
detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not  
sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every  
kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like  
smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits,  
children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the  
detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to  
prevent injury or death.  
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation  
manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and  
intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes  
place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking,  
painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection  
ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area  
approaches the temperature range of 90° to 105°F, the detection performance can decrease.  
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other  
side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they  
are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the  
alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices,  
however loud, may not warn hearing-impaired people or waken deep sleepers.  
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or  
temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.  
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect  
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.  
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as  
long as 10 years, the electronic components could fail at any time.  
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This  
alarm system should be tested weekly to make sure all sensors and transmitters are working properly.  
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance.  
Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their  
lives and property.  
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to  
learn about these developments.  
76 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INDEX –  
A
E
Alarm Cancelled ........................... 7, 23, 24  
Alarm Exit Error .................................... 23  
Alarms........................................................ 8  
Armed Indicator................................. 17, 22  
Audible Emergency/Audible Alarm........ 29  
Auto Stay Feature ............................... 7, 19  
Away Mode...........................6, 9, 20, 22, 23  
E-Mail Events ..........................................45  
Entering Test Mode .................................63  
Entry Delay............6, 12, 18, 20, 22, 23, 24  
Exit Alarms ......................................... 7, 23  
Exit Delay.................................................23  
Exit Time Restart-Exit Delay  
Restart/Reset .........................................7  
Exit/Entry Delays ......................................7  
B
Babysitter Code ........................... 18, 20, 33  
Battery......14, 17, 60, 61, 62, 64, 65, 66, 67  
Battery Conditions .................................. 65  
Battery Low ............................................. 66  
Battery Pack ............................................ 66  
Burglary Abort Window ............................ 7  
Burglary Protection......................... 5, 6, 12  
Burglary Protection.................................. 6  
Bypass a Zone ............................................ 9  
Bypassing Protection Zones...... 6,27,28, 33  
F
False Alarm Prevention Features.......7, 33  
False Alarms ........................................7, 23  
Features......................................................5  
Fire Alarm..............................14, 26, 29, 67  
Fire Alarm System...................................60  
Fire Protection ...........................................6  
H
Home Screen ..11, 15, 19, 21, 22, 25, 27, 31  
Home(Cancel) Key.................................15  
L
C
Central Monitoring Station................ 8, 76  
Checking System Status .......................... 9  
Chime Mode ............................... 6, 9, 10, 31  
Clock/Calendar............................ 42, 43, 44  
LCD Display.............................................15  
Liquid Crystal Display ............................15  
M
Master Menu........................................... 16  
Master User..........................................8, 33  
Master User Code16, 33, 34, 35, 37, 42, 45,  
49, 52, 63  
Memory of Alarm .....................................67  
Menu.....................................................9, 15  
Menu Screens...........................................16  
Message Center....................5, 9, 12, 16, 39  
Microphone.........................................12, 39  
Multi-Mode Feature.................................59  
D
Device Activation....................................... 6  
Device Programming Option................... 45  
Devices..................2, 6, 9, 20, 45, 49, 71, 76  
Dialer Test ............................................... 64  
Disarm.... 7, 8, 9, 12, 18, 20, 22, 23, 24, 25,  
33, 55, 67  
Disarming The System and Silencing  
Burglary Alarms................................. 25  
Duress Code, 33  
N
Navigation Keys.......................................15  
No Delay...................................................22  
77 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
T
P
Test Mode .......................................9, 63, 64  
Time and Date................................9, 16, 42  
Touchscreen Control......................5, 10, 11  
Triggers ....................................................45  
Two-Way Voice.......................................5, 8  
Panic Key ....................................... 5, 29, 60  
Personal Emergency/Aux. Alarm ........... 29  
Phone Control ............................................ 5  
Q
Quick Arm...................................... 9, 18, 20  
Quick Exit ................................................ 22  
U
Unrestricted Menu...................................16  
User Access.......................33, 45, 46, 47, 48  
User Codes............................................5, 33  
R
Ready Indicator................11, 17, 18, 20, 25  
Ready LED............................................... 17  
Real-Time Clock......................................... 5  
Rechargeable, Nickel-Metal Hydride  
Battery Pack........................................ 66  
Record a Message ...................................... 9  
Reminder Feature.................................... 52  
Remote Access Feature ........................... 59  
Remote Interactive Phone Capability .... 57  
Remote Phone Control............... 3, 5, 57, 58  
Remote Services....................................... 59  
Restart Exit Delay..................................... 9  
Restarting Exit Delay.............................. 23  
V
Voice Dialog................................................8  
Volume Adjustment...................................9  
Volume Level................................10, 17, 41  
W
Walk Test ...........................................63, 64  
Wireless Keypads.......................................5  
Wireless Sensors......................................65  
Z
Zones ......................5, 6, 8, 17, 19, 27, 28, 64, 67  
S
Schedules..............................6, 9, 16, 49, 51  
Scheduling Feature ............................ 6, 49  
Security Codes ....................................... 5, 8  
Security Functions..................................... 9  
Servicing Information.............................. 75  
Silence Alarm....................................... 9, 25  
Silencing a Fire/Carbon Monoxide Alarm..  
.............................................................. 60  
Silencing Low Battery Warning Tones .. 65  
Silent Emergency/Silent Alarm.............. 29  
Smoke Detectors..........6, 60, 61, 64, 65, 76  
SMS Feature............................................ 59  
Speaker Phone .........5, 9, 10, 11, 12, 55, 69  
Status Area .............................................. 15  
Stay Mode................................... 6, 9, 18, 22  
System Adjustments................................ 41  
System Battery ........................................ 66  
System Status.......................................... 17  
78 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TWO YEAR LIMITED WARRANTY  
Honeywell International Inc., acting through its Security & Communications business (Seller), 2 Corporate Center  
Drive, Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under  
normal use and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided,  
however, that in the event the Buyer presents a proper invoice relating to the purchased product and such invoice  
bears a date later than the manufacture date, then Seller may at its discretion, reflect the warranty period as  
commencing at invoice date. Except as required by law, this Limited Warranty is only made to Buyer and may not  
be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at its sole  
option and as the exclusive remedy hereunder, free of charge, any defective products.  
Seller shall have no obligation under this Limited Warranty or otherwise if the product:  
(i)is improperly installed, applied or maintained;  
(ii)installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than  
the Seller/Sellers Authorized Service/Repair Center;  
(iii)damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or  
the like; or  
(iv)defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes  
unrelated to defective materials or workmanship, or failures related to batteries of any type used in  
connection with the products sold hereunder.  
Exceptions to Warranty With Respect to Honeywell Products listed below:  
Hardwire Contacts and PIRs Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of  
the above limited warranty for a period of five (5) years from the manufacture date code.  
EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY  
THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR  
FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION  
ON THE FACE HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE  
LIABLE TO ANYONE FOR ANY (i) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE  
DAMAGES ARISING OUT OF OR RELATING IN ANY WAY TO THE PRODUCT AND/OR FOR BREACH OF  
THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS  
OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLERS OWN  
NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH  
LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Sellers agents),  
specifications, samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in  
connection with the Buyers order are for the sole purpose of identifying the Sellers products and shall not be  
construed as an express warranty or condition. Any suggestions by Seller or Sellers agents regarding use,  
applications, or suitability of the products shall not be construed as an express warranty or condition unless  
confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be  
compromised or circumvented; that the products will prevent any personal injury or property loss by burglary,  
robbery, fire or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer  
understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery or fire  
without warning, but it is not insurance or a guarantee that such will not occur or will not cause or lead to personal  
injury or property loss. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL  
INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON ANY CLAIM AT ALL INCLUDING A CLAIM THE  
PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether directly or indirectly for any loss  
or damage with respect to the products it sells, regardless of cause or origin, its maximum liability shall not in any  
case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and  
shall be the complete and exclusive remedy against the Seller. Should your product become defective during the  
warranty, please contact your installer to facilitate repair or replacement with Seller pursuant to the terms hereof.  
Seller reserves the right to replace any defective product under warranty with new, refurbished, or remanufactured  
product.  
79 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2 Corporate Center Drive, Suite 100  
P.O. Box 9040, Melville, NY 11747  
Copyright © 2011 Honeywell International Inc.  
Ê800-06894}Š  
800-06894 1/11 Rev. A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Gym 9757 User Manual
Graco Baby Gym ISPP072AC User Manual
Graco Crib ISPP008AB User Manual
Grizzly Saw G0664 User Manual
Haier Clothes Dryer HDY60M User Manual
Harbor Freight Tools Air Cleaner 98904 User Manual
Harbor Freight Tools Laser Level 91179 User Manual
Harmar Mobility Personal Lift CPL1000 User Manual
Honeywell Home Security System 16103 User Manual
HP Hewlett Packard Projector TC33096003 User Manual