| ML4125, ML4135, ML8125, ML8135   Fast-Acting, Two-Position Actuators   FOR HEATING, VENTILATION AND   AIR-CONDITIONING APPLICATIONS   PRODUCT DATA   FEATURES   • • • • Integral spring return.   -40 to 130°F (-40 to 54°C) operating temperature range.   No audible noise during holding.   Electronic circuitry provides efficient operation while   eliminating the need for limit switches.   • • • • Ninety-five degree angle of rotation.   Die-cast aluminum housing.   Housing design allows flush mounting to damper.   Integral junction box with three conduit openings   eliminates need for separate wiring box.   • Direct mounting to 3/8 or 1/2 in. round or square shaft.   ML4125, ML8125   • • • 100 lb-in. (11.3 N•m) minimum driving torque.   25 to 40 second drive timing (load dependant).   Models available for 24, 120, and 230 Vac.   ML4135, ML8135   • • • 40 lb-in. (4.5 N•m) minimum driving torque.   20 to 25 second drive timing (load dependant).   Models available for 24 and 120 Vac.   APPLICATION   The ML4125, ML4135, ML8125 and ML8135 Fast-Acting,   Two-Position Actuators are spring return direct coupled   actuators (DCA) with an integral junction box for on/off   damper control. The actuator accepts an on/off signal from   a single-pole, single-throw (spst) controller. Models are   available with clockwise (cw) or counterclockwise (ccw)   spring return and are designed for heating, ventilation, and   air-conditioning (HVAC) applications.   APPLICABLE LITERATURE   — Motor/Actuator Selection Guide   for Damper Applications   — Engineering Manual of Automatic Control   (also called The Gray Manual)   — Direct Coupled Actuator   63-8419   77-1100   IMPORTANT   This actuator is not to be used in fire/smoke   applications requiring UL555/555S approval.   Quick Selection Guide   63-8553   63-8437   — Damper Torque Calculator   Contents   ® U.S. Registered Trademark   Copyright © 2000 Honeywell • All Rights Reserved   N314   63- 2567- 3   Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   Mounting:   Table 3. Approvals.   3/8 in. (10 mm) to 1/2 in. (13 mm) square or round damper   shafts. Actuator can be mounted with shaft in any position.   Secure hub to shaft with:   ML4125   A,B C,D ML4135 ML8125 ML8135   ML8125, ML4125A,B: Four 1/4-28 UNF set screws. Use   1/8 in. Allen wrench to tighten set screws.   ML8135, ML4135: Two 1/4-28 UNF set screws. Use 1/8 in.   Allen wrench to tighten set screws.   UL/cUL   X X X X X X X X X X UL873   Plenum Rating,   File No. E4436   ML4125C,D: Four 3 mm set screws. Use 3 mm Allen wrench   to tighten set screws.   CE   X X X X X C-TICK   IMPORTANT   Honeywell does not recommend using linkages with   these actuators because side-loading of the output   hub reduces actuator life.   2 (51)   1 (25)   Minimum Damper Shaft Length:   1-3/4 in. (45 mm).   5/8   (17)   1 Timing:   Drive Open:   6 3/8   (161)   ML4125, ML8125: 25 to 40 seconds (load dependant).   ML4135, ML8135: 20 to 25 seconds (load dependant).   Spring Close:   ML4125, ML8125: 20 to 25 seconds.   ML4135, ML8135: 15 seconds.   7 1/2   (192)   Design Life (at Rated Voltage):   ML4125, ML8125: 80,000 full-stroke cycles.   ML4135, ML8135: 60,000 full-stroke cycles.   Environmental Protection Ratings:   Table 2. Environmental Ratings.   All Devices ML4125C,D, ML8125, ML8135   IP54   2 (51)   3 5/16 (84)   4 (102)   1/16 (2)   NEMA1   7/8 (22)   Approvals:   1 ML4135/ML8135 HAVE SHORTER   HUB WITH TWO SET SCREWS.   ML4125/ML8125 HAVE LONGER   HUB WITH FOUR SET SCREWS.   Accessories:   201391 Shaft Adapter for 3/8 in. (10 mm) shafts.   205649 Mounting Bracket (included with the actuator).   32003532-001 Adjustable Switch Package, two 10A   externally-mounted fully-adjustable switches.   5 1/8 (129)   M17538   Fig. 1. ML4125/4135, ML8125/8135   dimensiona drawing in in. (mm).   3 63-2567—3   Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   INSTALLATION   When Installing this Product...   1.   Read these instructions carefully. Failure to follow them   could damage the product or cause a hazardous   condition.   2.   Check the ratings given in the instructions and on the   product to make sure the product is suitable for your   application.   3.   4.   Installer must be a trained, experienced service   technician.   After installation is complete, check out product   operation as provided in these instructions.   1 IMPORTANT   All wiring must agree with applicable codes,   ordinances and regulations.   WARNING   Electrical Power Hazard.   Line voltage can cause death or serious injury   and short equipment circuitry.   Disconnect power supply before installation.   1 ENSURE THAT MOUNTING ASSEMBLY PREVENTS ACTUATOR   ROTATION AND ALLOWS ACTUATOR TO FLOAT ALONG INDICATED   AXIS. WHEN TOO TIGHT, THE RESULTING BINDING CAN DAMAGE   CAUTION   Electrical Shock or Equipment Damage Hazard.   Low voltage can shock individuals or short   equipment circuitry.   THE ACTUATOR OR REDUCE TORQUE OUTPUT.   M17519   Fig. 2. Mounting actuator to damper housing.   Disconnect power supply before installation.   NOTE: The actuator mounts flush with the damper box.   Location and Mounting   Preparation   Before mounting the actuator onto the damper shaft, determine   the damper shaft size (3/8 in. to 1/2 in. [10 mm to 13 mm]).   CAUTION   Equipment Damage Hazard.   Tightly securing actuator to damper housing can   damage actuator.   Mount actuator to allow it to float along its vertical axis.   If damper shaft is 3/8 in. (10 mm) round or square, use part   number 201391 Shaft Adapter. Place adapter opposite   set screws (see Fig. 3).   The actuators are designed to open a damper by driving the   NOTE: The damper shaft adapter centers a 3/8 in. (10 mm)   damper shaft in the hub. Failure to use adapter can   cause mounting screws to loosen. A 1/2 in. (13 mm)   damper shaft does not require an adapter.   damper shaft in either clockwise   or counterclockwise   direction. The actuator housing has two slots on the   bottom that, with a 205649 Mounting Bracket, secure it flush   to a damper box (see Fig. 2). When mounted correctly, these   float   slots allow the actuator to   damper shaft.   without rotating relative to the   SHAFT ADAPTER   NOTE: ML4125, ML4135, ML8125 and ML8135 Actuators   are shipped in the fully closed position.   M2064   Fig. 3. Using damper shaft adapter for   3/8 in. (10 mm) damper shafts.   63-2567—3   4 Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   IMPORTANT   Installation   1. All wiring must comply with local electrical codes,   ordinances and regulations.   2. Voltage and frequency of transformer used with   ML8125 or ML8135 must correspond with the   characteristics of power supply and actuator.   3. Use wires rated for at least 75°C (167°F).   CAUTION   Improper set screw tightening causes device   Device Malfunction Hazard.   malfunction.   Tighten set screws with proper torque to prevent   damper shaft slippage.   CAUTION   Using actuator as shaft bearing causes device   ( ( ) ) L1   L2   Actuator Damage Hazard.   RED   R W 24 VAC   BLACK   damage.   Use actuator only to supply rotational torque. Avoid   any side loads to actuator output coupling bearings.   M17585   To install actuator, proceed as follows:   1.   Place actuator over damper shaft; and hold mounting   bracket in place. See Fig. 2.   Fig. 4. Typical 24 Vac wiring.   2.   3.   4.   Mark screw holes on damper housing.   Remove actuator and mounting bracket.   Drill or center-punch holes for mounting screws (or use   no.10 self-tapping sheet metal screws).   ( ( ) ) L1   5.   6.   Turn damper blades to desired normal (closed) position.   Place actuator and mounting bracket back into position   and secure bracket to damper box with sheet metal   screws.   BLACK   R W 120   VAC   WHITE   L2   7.   Tighten set screws securely into damper shaft using   minimum 30 lb-in., maximum 60 lb-in. torque. Use   1/8 in. or 3 mm Allen wrench (see Specifications for   details) to tighten set screws.   M17589   Fig. 5. Typical 120 Vac wiring.   Wiring   WARNING   Line voltage can cause death or serious injury   ( ( ) ) L1   BROWN   Electrical Power Hazard.   R W 230   VAC   BLUE   and short equipment circuitry.   L2   Disconnect power supply before installation.   M17588   CAUTION   Fig. 6. Typical 230 Vac wiring.   Table 4. Color Translations.   Electrical Shock or Equipment Damage Hazard.   Low voltage can shock individuals or short   equipment circuitry.   Disconnect power supply before installation.   G F BRUN   BLEU   I E BROWN   BLUE   BRAUN   BLAU   BRUNO   CAFE   AZZURRO AZUL   BLACK   WHITE   RED   SCHWARZ NOIR   NERO   NEGRO   WEISS   ROT   BLANC   ROUGE   BIANCO   ROSSO   BLANCO   ROJO   5 63-2567—3   Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   OPERATION   CHECKOUT   The actuators are operated by an spst two-position controller.   When using an spst two-position controller, the actuator drives   to the damper fully open position when controller contact   makes and spring returns to the damper fully closed position   when controller contact breaks. The actuator drops to holding   power level on detection of stall, independent of hub position.   ML4125A,B, ML4135 (120 Vac model)   1.   2.   Check damper position.   Connect 120 Vac to the black and white leadwires to   drive the damper to the open position. The actuator   should drive the damper.   3.   4.   5.   6.   If the actuator does not run, remove power for at least   two seconds.   If power fails, the actuator spring returns to the 0° position.   If the actuator spring returns, allow it to close entirely,   then return to step 2.   If the actuator does not spring return, verify that the   actuator is properly installed. See Installation section.   I f the actuator is correctly installed but neither runs nor   spring returns, replace the actuator.   ML4125C,D (230 Vac model)   1.   2.   Check damper position.   Connect 230 Vac to the blue and brown leadwires to   drive the damper to the open position. The actuator   should drive the damper.   3.   4.   5.   6.   If the actuator does not run, remove power for at least   two seconds.   If the actuator spring returns, allow it to close entirely,   then return to step 2.   If the actuator does not spring return, verify that the   actuator is properly installed. See Installation section.   I f the actuator is correctly installed but neither runs nor   spring returns, replace the actuator.   ML8125, ML8135 (24 Vac model)   1.   2.   Check damper position.   Connect 24 Vac to the red and black leadwires to drive   the damper to the open position. The actuator should   drive the damper.   3.   4.   5.   6.   If the actuator does not run, remove power for at least   two seconds.   If the actuator spring returns, allow it to close entirely,   then return to step 2.   If the actuator does not spring return, verify that the   actuator is properly installed. See Installation section.   If the actuator is correctly installed but neither runs nor   spring returns, replace the actuator.   63-2567—3   6 Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   D F I Montageanweisung   Instructions d’Installation   Istruzioni per I’Installazione   NL Installatievoorschrift   DK Installasjonsinstruks   N Installationsinstrukioner   SF Asennusohje   S E Installations Instrukioner   Instrucciones de montaje   A2   A A1, A4   24 VAC   230 VAC   ! d ASSEMBLY   EINBAU   D F I MONTAGE   MONTAGGIO   a NL MONTAGE   DK MONTERE   N MONTERING   a FIN ASENTAMINEN   S E MONTERA   MONTAJE   b M11874   b c M11875   M11876   M11876   A3   A5   A6   MIN: 45 lb-in. (5.1 Nm)   MAX: 60lb-in. (6.8 Nm)   b HEX   4mm   c a a b b a M12030   M11881   M11882   7 63-2567—3   Download from Www.Somanuals.com. All Manuals Search And Download.   ML4125, ML4135, ML8125, ML8135 FAST-ACTING, TWO-POSITION ACTUATORS   B B1   B2   B4   24 VAC   230 VAC   ! a b M11887   DISASSEMBLY   AUSBAU   DÉMONTAGE   SMONTAGGIO   D F I M11886   NL DEMONTAGE   DK AFMONTERE   DEMONTERE   FIN PURKAMINEN   N B3   S E NEDMONTERA   DESMONTAJE   M11884   a HEX   4mm   b M11885   M11888   Home and Building Control Home and Building Control   Honeywell Asia Pacific Inc. Honeywell Europe S.A. Honeywell Latin American   Honeywell   Honeywell Limited-Honeywell Limitée   Room 3213-3225   Sun Hung Kai Centre   No. 30 Harbour Road   Wanchai   3 Avenue du Bourget   1140 Brussels   Belgium   Region   480 Sawgrass Corporate Parkway   Suite 200   Sunrise FL 33325   1985 Douglas Drive North   Golden Valley, MN 55422   35 Dynamic Drive   Scarborough, Ontario   M1V 4Z9   Hong Kong   Printed in U.S.A. on recycled   paper containing at least 10%   post-consumer paper fibers.   63-2567—3 B.B. Rev. 7-00   Download from Www.Somanuals.com. All Manuals Search And Download.   |