CH-LOPTB
May, 2008
Replaces CH-B-15B, March 2004y
2007
LOW PROFILE
UNIT COOLER
Technical Guide
Models RLC | Air Defrost
ELC/EFC | Electric Defrost
GLC | Hot Gas Defrost
Download from Www.Somanuals.com. All Manuals Search And Download.
Features & Benefits
Cabinet
• Minimal height of the low profile series makes it ideal for low ceiling coolers
• Cabinet design features front access panels on each side for easy access to electrical and refrigeration components
• All electrical components factory wired to terminal board and identified, making it easy to field wire the unit
• Sweat connections to reduce potential for leaks
• Internal panels are isolated for quiet operation
• Liquid line solenoid wire harness is factory-installed for quick installation
• Pre-drilled holes on the back of the unit for room thermostat
Coil
• Internally enhanced tubing and fin design for higher efficiency
• Coil heater slots have been enlarged for easier installation and replacement
• Reduced heater wattages
• Hot gas loop on bottom of coil for easier access is standard for hot gas defrost models
• Fixed defrost termination for electric, adjustable defrost termination for hot gas
Drain Pan
• Large diameter drain hole (3/4" ID) is located on the back of the unit
• Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in
end compartments
• On 4-6 fan models, drain pan has a lanyard for easy and safe access
Motors
• Motors plug into wiring harness for easier servicing
• EC motors available factory-installed or as a drop-in replacement through InterLink™ Commercial Refrigeration Parts in
115/1/60, 208-230/1/60 and 208-230/3/60 unit voltages
• PSC and PSC (Totally Enclosed) motors for 115/1/60, 208-230/1/60 and 460/1/60 unit voltages
• PSC motors or EC motors required for 50 Hz operation
Options
• Unit Configurations: mounted components, pre-assembled, pre-charged and Beacon II™
- Units available with mounted TXV and mounted TXV / solenoid valve
- Pre-assembled units come with mounted TXV, liquid line solenoid valve and room thermostat. Available in a master
liquid line configuration
- Pre-charged units come with mounted TXV, liquid line solenoid valve, room thermostat and quick connect fittings
- Various room thermostat variations including rear mount and front access versions
- Beacon II units come with electronic expansion valves, pressure transducer, temperature sensors and Beacon
control board
• Units available with stainless steel housing and drain pan
•
Units available with copper fins. Air defrost units also available with polyester coated fins or various coil coatings options
• Units available with insulated drain pan
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance Data
Model RLC Air Defrost | 60 Hz
Capacity
Fan Data
10°F TD
25°F SST
6°C TD
Model
No.
CFM
m3H
-4°C SST
Watts
1,170
1,520
1,900
2,050
2,640
3,050
3,500
3,810
4,100
4,570
5,270
6,100
7,620
9,140
10,840
BTUH
4,000
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
730
1,240
1,189
1,104
2,481
2,379
2,379
2,209
2,209
3,568
3,568
3,313
4,758
5,522
6,627
6,627
5,200
700
6,500
650
7,000
1,460
1,400
1,400
1,300
1,300
2,100
2,100
1,950
2,800
3,250
3,900
3,900
9,000
10,400
12,000
13,000
14,000
15,600
18,000
20,800
26,000
31,200
37,000
Model RLC Air Defrost | 50 Hz †
Capacity
Fan Data
10°F TD
25°F SST
6°C TD
-4°C SST
Model
No.
CFM
m3H
BTUH
3,800
Watts
1,112
1,445
1,807
1,946
2,502
2,891
3,335
3,613
3,891
4,336
5,003
5,781
7,226
8,672
10,284
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
670
1,117
1,070
995
4,940
630
6,175
586
6,650
1,315
1,260
1,260
1,170
1,170
1,891
1,891
1,756
2,521
2,927
3,512
3,512
2,234
2,142
2,142
1,989
1,989
3,213
3,213
2,984
4,284
4,973
5,967
5,967
8,550
9,880
11,400
12,350
13,300
14,820
17,100
19,760
24,700
29,640
35,150
† For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will
not see a reduction in performance due to the electronic control of the motor)
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Model RLC Air Defrost | 60 Hz
Shaded Pole Motor
PSC, PSC-TE Motor
208-230/1/60
EC Motor
Model
HP
115/1/60
208-230/1/60
115/1/60
460/1/60
115/1/60
208-230/1/60
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1.8
1.8
1.8
3.6
3.6
3.6
3.6
3.6
5.4
5.4
5.4
7.2
9.0
116
116
116
232
232
232
232
232
348
348
348
464
580
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
4.0
5.0
6.0
6.0
122
122
122
244
244
244
244
244
366
366
366
488
610
732
732
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
4.0
5.0
6.0
6.0
82
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
2.0
2.5
3.0
3.0
91
0.4
0.4
0.4
0.8
0.8
0.8
0.8
0.8
1.2
1.2
1.2
1.6
2.0
2.4
2.4
117
117
117
234
234
234
234
234
351
351
351
468
585
702
702
0.9
0.9
0.9
1.8
1.8
1.8
1.8
1.8
2.7
2.7
2.7
3.6
4.5
5.4
5.4
57
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
2.0
2.5
3.0
3.0
59
82
91
57
59
82
91
57
59
164
164
164
164
164
246
246
246
328
410
492
492
182
182
182
182
182
273
273
273
364
455
546
546
114
114
114
114
114
171
171
171
228
285
342
342
118
118
118
118
118
177
177
177
236
295
354
354
1/15 10.8 696
1/15 10.8 696
Model RLC Air Defrost | 50 Hz
PSC Motor
220/1/50
EC Motor
Model
HP
110/1/50
380/1/50
110/1/50
220/1/50
Amps
Watts
68
Amps
Watts
Amps
0.4
0.4
0.4
0.8
0.8
0.8
0.8
0.8
1.2
1.2
1.2
1.6
2.0
2.4
2.4
Watts
82
Amps
Watts
Amps
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
2.0
2.5
3.0
3.0
Watts
59
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1.0
1.0
1.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
4.0
5.0
6.0
6.0
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
2.0
2.5
3.0
3.0
65
0.9
0.9
0.9
1.8
1.8
1.8
1.8
1.8
2.7
2.7
2.7
3.6
4.5
5.4
5.4
57
68
65
82
57
59
68
65
82
57
59
136
136
136
136
136
204
204
204
272
340
408
408
130
130
130
130
130
195
195
195
260
325
390
390
164
164
164
164
164
246
246
246
328
410
492
492
114
114
114
114
114
171
171
171
228
285
342
342
118
118
118
118
118
177
177
177
236
295
354
354
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance Data
Model ELC/EFC Electric Defrost | 60 Hz
Capacity
Fan Data
10°F TD
-20°F SST
BTUH
6°C TD
-29°C SST
Watts
Model
No.
CFM
m3H
ELC035
3,500
4,000
4,700
6,500
7,500
1,025
1,170
1,380
1,900
2,200
2,640
3,520
4,100
4,690
5,280
5,860
7,030
8,200
1,200
2,000
2,340
2,990
3,990
4,980
5,980
6,880
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
700
700
650
1,189
1,189
1,104
2,379
2,209
2,209
3,568
3,313
4,418
4,418
5,522
6,627
6,627
1,172
2,345
2,345
3,687
4,690
5,862
7,035
7,035
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
1,400
1,300
1,300
2,100
1,950
2,600
2,600
3,250
3,900
3,900
690
1,380
1,380
2,170
2,760
3,450
4,140
4,140
Capacity Correction Factors For
Electric and Hot Gas Defrost Units
Saturated Suction
+20 -10 -20 -30
Temperature °F
9,000
12,000
14,000
16,000
18,000
20,000
24,000
28,000
4,100
Saturated Suction
Temperature °C
-7
-23 -29 -34
Multiply Capacity
By
1.15 1.04 1.00 0.90
6,800
8,000
10,200
13,600
17,000
20,400
23,500
Model ELC/EFC Electric Defrost | 50 Hz †
Capacity
Fan Data
10°F TD
-20°F SST
BTUH
6°C TD
-29°C SST
Watts
Model
No.
CFM
m3H
ELC035
3,325
3,800
4,465
6,175
7,125
974
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
630
630
586
1,070
1,070
995
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
1,113
1,308
1,809
2,087
2,504
3,339
3,896
4,452
5,009
5,565
6,678
7,791
1,141
1,892
2,226
2,838
3,784
4,731
5,677
6,539
1,260
1,170
1,170
1,891
1,756
2,341
2,341
2,927
3,512
3,512
621
1,243
1,243
1,954
2,485
3,107
3,728
3,728
2,142
1,989
1,989
3,213
2,984
3,978
3,978
4,973
5,967
5,967
1,056
2,111
2,111
3,320
4,223
5,279
6,334
6,334
8,550
11,400
13,300
15,200
17,100
19,000
22,800
26,600
3,895
6,460
7,600
9,690
12,920
16,150
19,380
22,325
† For EC motors, use 60 Hz capacity and airflow values (Units with EC motors
operating at 50 Hz will not see a reduction in performance due to the electronic
control of the motor)
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Model ELC/EFC Electric Defrost | 60 Hz
Shaded Pole Motor
208-230/1/60
PSC, PSC-TE Motor
EC Motor
208-230/1/60
Defrost Heaters
208-230/1/60
460/1/60
230/1/60
230/3/60
Total Amps
2.3
460/1/60
Model
HP
Watts
Amps
1.0
1.0
1.0
2.0
2.0
2.0
3.0
3.0
4.0
4.0
5.0
6.0
6.0
1.0
2.0
2.0
3.0
4.0
5.0
6.0
6.0
Watts
122
122
122
244
244
244
366
366
488
488
610
732
732
122
244
244
366
488
610
732
732
Amps Watts Amps Watts Amps Watts
ELC035
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
0.5
0.5
0.5
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.5
3.0
3.0
0.5
1.0
1.0
1.5
2.0
2.5
3.0
3.0
91
91
91
0.4
0.4
0.4
0.8
0.8
0.8
1.2
1.2
1.6
1.6
2.0
2.4
2.4
0.4
0.8
0.8
1.2
1.6
2.0
2.4
2.4
117
117
117
234
234
234
351
351
468
468
585
702
702
117
234
234
351
468
585
702
702
0.5
0.5
0.5
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.5
3.0
3.0
0.5
1.0
1.0
1.5
2.0
2.5
3.0
3.0
59
59
59
900
900
900
3.9
3.9
2.0
2.0
2.0
3.9
3.9
3.9
5.9
5.9
7.8
7.8
9.8
11.7
11.7
2.0
3.9
3.9
5.9
7.8
9.8
11.7
11.7
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
2.3
3.9
2.3
182
182
182
273
273
364
364
455
546
546
91
182
182
273
364
455
546
546
118
118
118
177
177
236
236
295
354
354
59
118
118
177
236
295
354
354
1,800
1,800
1,800
2,700
2,700
3,600
3,600
4,500
5,400
5,400
900
1,800
1,800
2,700
3,600
4,500
5,400
5,400
7.8
4.5
7.8
4.5
7.8
4.5
11.7
11.7
15.7
15.7
19.6
23.5
23.5
3.9
6.8
6.8
9.0
9.0
11.3
13.6
13.6
2.3
7.8
4.5
7.8
4.5
11.7
15.7
19.6
23.5
23.5
6.8
9.0
11.3
13.6
13.6
Model ELC/EFC Electric Defrost | 50 Hz
PSC Motor
EC Motor
220/1/50
Defrost Heaters
220/1/50 220/3/50 380/1/50
220/1/50
380/1/50
Model
HP
Watts
Amps
Watts
Amps
0.4
0.4
0.4
0.8
0.8
0.8
1.2
1.2
1.6
1.6
2.0
2.4
2.4
0.4
0.8
0.8
1.2
1.6
2.0
2.4
2.4
Watts
Amps
Watts
Total Amps
ELC035
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
1/15
0.5
0.5
0.5
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.5
3.0
3.0
0.5
1.0
1.0
1.5
2.0
2.5
3.0
3.0
65
65
65
82
82
82
0.5
0.5
0.5
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.5
3.0
3.0
0.5
1.0
1.0
1.5
2.0
2.5
3.0
3.0
59
59
59
823
823
823
3.7
3.7
3.7
7.5
7.5
2.2
2.2
2.2
4.3
4.3
4.3
6.5
6.5
8.6
1.6
1.6
1.6
3.2
3.2
3.2
4.9
4.9
6.5
6.5
8.1
9.7
9.7
1.6
3.2
3.2
4.9
6.5
8.1
9.7
9.7
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
130
130
130
195
195
260
260
325
390
390
65
130
130
195
260
325
390
390
164
164
164
246
246
328
328
410
492
492
82
164
164
246
328
410
492
492
118
118
118
177
177
236
236
295
354
354
59
118
118
177
236
295
354
354
1,647
1,647
1,647
2,470
2,470
3,294
3,294
4,117
4,941
4,941
823
1,647
1,647
2,470
3,294
4,117
4,941
4,941
7.5
11.2
11.2
15.0
15.0
18.7
22.5
22.5
3.7
8.6
10.8
13.0
13.0
2.2
4.3
4.3
6.5
8.6
10.8
13.0
13.0
7.5
7.5
11.2
15.0
18.7
22.5
22.5
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance Data
Model GLC Hot Gas Defrost | 60 Hz
Capacity
Fan Data
CFM
10°F TD
-20°F SST
6°C TD
-29°C SST
Model
No.
m3H
BTUH
3,500
4,000
4,700
6,500
Watts
1,025
1,170
1,380
1,900
2,200
2,640
3,520
4,100
4,690
5,280
5,860
7,030
8,200
1,200
2,000
2,340
2,990
3,990
4,980
5,980
6,880
GLC035
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
700
700
650
1,189
1,189
1,104
2,379
2,209
2,209
3,568
3,313
4,418
4,418
5,522
6,627
6,627
1,172
2,345
2,345
3,687
4,690
5,862
7,035
7,035
GLC040
GLC047
GLC065
GLC075
GLC090
GLC120
GLC140
GLC160
GLC180
GLC200
GLC240
GLC280
GLC041
GLC068
GLC080
GLC102
GLC136
GLC170
GLC204
GLC235
1,400
1,300
1,300
2,100
1,950
2,600
2,600
3,250
3,900
3,900
690
1,380
1,380
2,170
2,760
3,450
4,140
4,140
Capacity Correction Factors For
Electric and Hot Gas Defrost Units
Saturated Suction
+20 -10 -20 -30
Temperature °F
7,500
9,000
12,000
14,000
16,000
18,000
20,000
24,000
28,000
4,100
Saturated Suction
Temperature °C
-7
-23 -29 -34
Multiply Capacity
By
1.15 1.04 1.00 0.90
6,800
8,000
10,200
13,600
17,000
20,400
23,500
NOTE: When using the hot gas units with a hot gas
loop drain pan on 0°F applications and below, an
insulated drain pan is required.
Model GLC Hot Gas Defrost | 50 Hz †
Capacity
Fan Data
CFM
10°F TD
-20°F SST
6°C TD
-29°C SST
Model
No.
m3H
BTUH
3,325
3,800
4,465
6,175
7,125
8,550
11,400
1,950
2,600
2,600
3,250
3,900
3,900
690
1,380
1,380
2,170
2,760
3,450
4,140
4,140
Watts
974
GLC035
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
630
630
586
1,070
1,070
995
GLC040
GLC047
GLC065
GLC075
GLC090
GLC120
GLC140
GLC160
GLC180
GLC200
GLC240
GLC280
GLC041
GLC068
GLC080
GLC102
GLC136
GLC170
GLC204
GLC235
1,113
1,308
1,809
2,087
2,504
3,339
3,313
4,418
4,418
5,522
6,627
6,627
1,172
2,345
2,345
3,687
4,690
5,862
7,035
7,035
1,260
1,170
1,170
1,891
1,756
2,341
2,341
2,927
3,512
3,512
621
1,243
1,243
1,954
2,485
3,107
3,728
3,728
2,142
1,989
1,989
3,213
2,984
3,978
3,978
4,973
5,967
5,967
1,056
2,111
2,111
3,320
4,223
5,279
6,334
6,334
† For EC motors, use 60 Hz capacity and airflow values (Units with EC motors
operating at 50 Hz will not see a reduction in performance due to the electronic
control of the motor)
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Model GLC Hot Gas Defrost | 60 Hz
Shaded Pole Motor
PSC, PSC-TE Motor
EC Motor
Drain Pan Heaters*
115/1/60 230/1/60 460/1/60
Total Amps
208-
115/1/60
208-
208-
230/1/60
Model
HP
115/1/60
460/1/60 115/1/60
230/1/60
230/1/60
Watts
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
GLC035 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59
GLC040 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59
GLC047 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59
300
300
300
2.6
2.6
2.6
5.2
5.2
5.2
7.8
7.8
10.4
10.4
13.0
15.7
15.7
2.6
5.2
5.2
7.8
1.3
1.3
1.3
2.6
2.6
2.6
3.9
3.9
5.2
5.2
6.5
7.8
7.8
1.3
2.6
2.6
3.9
5.2
6.5
7.8
7.8
0.7
0.7
0.7
1.3
1.3
1.3
2.0
2.0
2.6
2.6
3.3
3.9
3.9
0.7
1.3
1.3
2.0
2.6
3.3
3.9
3.9
GLC065 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600
GLC075 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600
GLC090 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600
GLC120 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900
GLC140 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900
GLC160 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200
GLC180 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200
GLC200 1/15 9.0 580 5.0 610 5.0 410 2.5 455 2.0 585 4.7 285 2.6 295 1,500
GLC240 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800
GLC280 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800
GLC041 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59
300
GLC068 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600
GLC080 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600
GLC102 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900
GLC136 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200
GLC170 1/15 9.0 580 5.0 610 5.0 410 2.5 455 2.0 585 4.7 285 2.6 295 1,500
GLC204 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800
GLC235 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800
10.4
13.0
15.7
15.7
Model GLC Hot Gas Defrost | 50 Hz
PSC Motor
220/1/50
EC Motor
Drain Pan Heaters*
Model
HP
110/1/50
380/1/50
110/1/50
220/1/50
110/1/50 220/3/50 380/1/50
Total Amps
Watts
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts
GLC035 1/15 1.0
GLC040 1/15 1.0
GLC047 1/15 1.0
GLC065 1/15 2.0
GLC075 1/15 2.0
GLC090 1/15 2.0
GLC120 1/15 3.0
GLC140 1/15 3.0
GLC160 1/15 4.0
GLC180 1/15 4.0
GLC200 1/15 5.0
GLC240 1/15 6.0
GLC280 1/15 6.0
GLC041 1/15 1.0
GLC068 1/15 2.0
GLC080 1/15 2.0
GLC102 1/15 3.0
GLC136 1/15 4.0
GLC170 1/15 5.0
GLC204 1/15 6.0
GLC235 1/15 6.0
68
68
68
0.5
0.5
0.5
1.0
1.0
1.0
1.5
1.5
2.0
2.0
2.5
3.0
3.0
0.5
1.0
1.0
1.5
2.0
2.5
3.0
3.0
65
65
65
0.4
0.4
0.4
0.8
0.8
0.8
1.2
1.2
1.6
1.6
2.0
2.4
2.4
0.4
0.8
0.8
1.2
1.6
2.0
2.4
2.4
82
82
82
1.1
1.1
1.1
2.0
2.0
2.0
2.9
2.9
3.8
3.8
4.7
5.6
5.6
1.1
2.0
2.0
2.9
3.8
4.7
5.6
5.6
57
57
57
0.6
0.6
0.6
1.1
1.1
1.1
1.6
1.6
2.1
2.1
2.6
3.1
3.1
0.6
1.1
1.1
1.6
2.1
2.6
3.1
3.1
59
59
59
275
275
275
549
549
549
823
823
2.5
2.5
2.5
5.0
5.0
5.0
7.5
7.5
10.0
10.0
12.5
15.0
15.0
2.5
5.0
5.0
7.5
1.3
1.3
1.3
2.5
2.5
2.5
3.7
3.7
5.0
5.0
6.2
7.5
7.5
1.3
2.5
2.5
3.7
5.0
6.2
7.5
7.5
0.6
0.6
0.6
1.1
1.1
1.1
1.6
1.6
2.2
2.2
2.7
3.2
3.2
0.6
1.1
1.1
1.6
2.2
2.7
3.2
3.2
136
136
136
204
204
272
272
340
408
408
68
136
136
204
272
340
408
408
130
130
130
195
195
260
260
325
390
390
65
130
130
195
260
325
390
390
164
164
164
246
246
328
328
410
492
492
82
164
164
246
328
410
492
492
114
114
114
171
171
228
228
285
342
342
57
114
114
171
228
285
342
342
118
118
118
177
177
236 1,098
236 1,098
295 1,372
354 1,649
354 1,649
59
275
549
549
823
118
118
177
236 1,098
295 1,372
354 1,649
354 1,649
10.0
12.5
15.0
15.0
* Optional with electric drain pan
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical Data
Model RLC Air Defrost
Approx. Net
Wt.
Connections (in.)
No. of
Model
Fans
Coil Inlet
OD
External
Suction ID
Drain MPT
lbs.
kg
Equalizer OD
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
5/8
5/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
1-1/8
1-1/8
1-1/8
1-3/8
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
28
31
34
45
48
49
51
53
63
67
69
82
103
124
127
13
15
16
21
22
23
24
25
29
31
32
38
47
57
58
Model ELC/EFC Electric Defrost
Approx. Net
Wt.
Connections (in.)
No. of
Model
Fans
Coil Inlet
OD
External
Suction ID
Drain MPT
lbs.
kg
Equalizer OD
ELC035
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
5/8
5/8
5/8
5/8
5/8
7/8
7/8
7/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
5/8
7/8
7/8
7/8
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
24
26
29
43
45
48
60
62
81
11
12
14
20
21
22
28
29
37
39
46
55
57
13
21
22
27
37
46
55
56
84
101
121
124
28
44
47
59
80
100
120
123
1-1/8
1-1/8
1-1/8
1-1/8
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Physical Data
Model GLC Hot Gas Defrost
Approx.
Net Wt.
Connections (in.)
No. of
Fans
Model
Coil
Inlet
ODF
External
Drain
Side
Port
OD
Hot Gas
Suction
ID
Equalizer
MPT
Pan Conns. lbs. kg
OD
OD
GLC035
GLC040
GLC047
GLC065
GLC075
GLC090
GLC120
GLC140
GLC160
GLC180
GLC200
GLC240
GLC280
GLC041
GLC068
GLC080
GLC102
GLC136
GLC170
GLC204
GLC235
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
5/8
5/8
5/8
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
5/8
26
28
31
45
47
50
62
64
83
86
103 47
123 56
126 57
30
46
49
61
82
12
13
15
21
22
23
29
30
38
40
5/8
5/8
5/8
5/8
5/8
5/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
7/8
1-1/8
1-1/8
1-1/8
1-1/8
1-1/8
5/8
1-1/8
1-1/8
1-1/8
1-1/8
5/8
14
21
23
28
38
5/8
7/8
5/8
7/8
7/8
7/8
7/8
1-1/8
1-1/8
1-1/8
1-1/8
7/8
102 47
122 56
125 57
7/8
1-1/8
The standard design for the Chandler Low Profile Evaporator incorporates a hot gas loop in the drain pan. Utilizing
a hot gas loop is ideal for hot gas defrost applications where high temperature gas can be maintained to defrost
both the evaporator drain pan and coil.
For applications where cooler (lower) temperature hot gas is used for defrosting, Chandler offers optional electric
heater elements in the drain pan to ensure quick and efficient defrost of the drain pan allowing condensate to
drain quickly, saving the hot gas for efficient evaporator coil defrost.
If the optional electric heating element drain pan is preferred, please specify when ordering, there is no additional
charge.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional Data
Dimensional Data For All Models
Air
Defrost
Model
Electric and
Hot Gas
Defrost Model
Dimensions
No.
of
Fans
A
B
C
D
6 FPI
040
052
065
070
090
104
120
130
140
156
180
208
-
6 FPI
035
040
047
-
4 FPI
-
in.
mm
in.
mm
438.1
438.1
438.1
845
in.
-
-
-
-
mm
in.
-
-
-
-
-
-
-
-
-
-
-
-
mm
-
1
1
1
2
2
2
2
2
3
3
3
4
4
5
6
6
29.50
29.50
29.50
749.3
749.3
749.3
17.25
17.25
17.25
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
041
-
-
45.50 1,155.7 33.25
45.50 1,155.7 33.25
45.50 1,155.7 33.25
45.50 1,155.7 33.25
45.50 1,155.7 33.25
61.50 1,562.1 49.25
61.50 1,562.1 49.25
61.50 1,562.1 49.25
77.50 1,968.5 65.25
77.50 1,968.5 65.25
93.50 2,374.9 81.25
109.50 2,781.3 97.25
109.50 2,781.3 97.25
-
065
-
-
845
-
-
-
845
-
-
075
090
120
-
068
080
102
-
845
-
-
845
-
-
1,251
1,251
1,251
1,657
1,657
2,064
2,470
2,470
-
-
-
-
-
-
140
160
180
200
240
280
-
-
-
-
-
136
170
204
235
-
-
260
312
370
48.63 1,235.1 32.63
48.63 1,235.1 48.63 1,235.1
48.63 1,235.1 48.63 1,235.1
828.7
NOTE: Hanger brackets will accept 3/8” / 9.5 mm hanger rods.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Hot Gas Reverse Cycle Kits
Shipped-loose
Factory-installed
TXV Bypass Assembly Kits
TXV Bypass Assembly Kits
GLC 6 FPI
035-075
090-160
180-280
SQE/SBF
50169210
50169211
50169212
EG
50169213
50169214
50169215
HFESC
50169216
50169217
50169218
SQE/SBF
52733701
52733702
52733703
EG
52733704
52733705
52733706
HFESC
52733707
52733708
52733709
GLC 4 FPI
041-080
102-204
235
50169210
50169211
50169212
50169213
50169214
50169215
50169216
50169217
50169218
52733701
52733702
52733703
52733704
52733705
52733706
52733707
52733708
52733709
Shipped-loose
Factory-installed
Drain Pan Loop
Check Valve Kit
Suction Line
Check Valve Kit
Drain Pan Loop
Check Valve Kit
Suction Line
Check Valve Kit
GLC 6 FPI
035-065
075-140
160-280
50169304
50169305
50169306
50169604
50169605
50169606
52733601
52733602
52733603
52733801
52733802
52733803
GLC 4 FPI
041
068-102
136-235
50169304
50169305
50169306
50169604
50169605
50169606
52733601
52733602
52733603
52733801
52733802
52733803
Recommendation is that both check valve kits are ordered: (For hot gas models with the hot gas loop drain
pan ONLY)
NOTE: The drain pan check valve kit can be ordered as an independent item. But the suction line check valve kit
must be ordered with the drain pan check valve kit in order to complete the piping.
NOTE: When using the hot gas units with a hot gas loop drain pan on 0°F applications and below, an insulated
drain pan is required.
The hot gas unit coolers can be used in reverse cycle hot gas defrost systems using multiple evaporators
connected to one condensing unit. Generally, not more than one-third of the system defrosts at one time.
During the reverse cycle defrost, the reversing
valve; located in the compressor discharge
line, diverts hot gas through the suction line
to the evaporator. See piping view in Figure
1. The suction line check valve directs the hot
gas through the drain pan loop which prevents
condensate in the pan from freezing. The hot
gas exits the loop at the pan loop outlet header
and enters the evaporator through the check
valve assembly. As the hot gas defrosts the coil,
heat is removed from the hot gas and eventually
it condenses into a liquid and exits the coil at
the distributor sideport. The liquid then flows
through the check valve of the thermostatic
expansion valve bypass assembly, around the
thermostatic expansion valve, and into the
system liquid line. The liquid refrigerant then
feeds other evaporators on the cooling cycle,
evaporates, and returns to the compressor
through their suction lines.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Hot Gas Reverse Cycle Kits (cont.)
In the refrigeration cycle, the thermostatic expansion
valve bypass assembly check valve only allows refrigerant
flow through the thermostatic expansion valve and into
the evaporator coil. As the refrigerant vapor exits the coil
at the suction line, the check valve of the drain pan loop
check valve assembly prevents the refrigerant vapor flow
through the drain pan loop.
Factory engineered assemblies (kits) are available for both
shipped-loose and factory-installed at an additional cost
to complete the reverse cycle piping and components.
The suction line check valve assembly includes the
suction line check valve and the piping for both the
suction line and the connection to the drain pan loop
inlet header. In order for the suction line check valve
assembly to be mounted, the drain pan loop check
valve assembly must be used. The drain pan loop check
valve assembly includes the check valve, suction line
tee and a bent pipe. The thermostatic expansion valve
bypass assembly option includes the check valve, tee
and necessary piping. In order for the thermostatic
expansion valve bypass assembly option to be complete,
a thermostatic expansion valve must be selected by the
sales engineer. The thermostatic expansion valve bypass
assembly option is dependent on the body style of the
thermostatic expansion valves which includes the Sporlan
SQE, SBF, EG and the Alco HFESC body styles. The factory-
installed thermostatic expansion valve bypass assembly
option must have the thermostatic expansion valve selection included on the order for the hot gas unit cooler.
To increase the efficiency, higher performance and greater system protection, a heat exchanger may be
beneficial to the system. In order to use a heat exchanger, the thermostatic expansion valve bypass assembly
option must be modified. See the piping view in Figure 2. The modification includes rerouting the pipe from the
thermostatic expansion valve bypass check valve to the inlet connection of the liquid line to the heat exchanger.
A pipe needs to be routed from the liquid line outlet connection of the heat exchanger to the inlet connection of
the thermostatic expansion valve.
The electrical control option includes an adjustable defrost termination and fan delay control (DTFD) which is
standard. For an additional cost, an optional (2) control electrical system is available with one adjustable control
for defrost termination (DT) and one fixed control for the fan delay (FD). For both the DTFD and DT adjustable
controls, the remote bulb position is with the bulb strapped to the piping of the thermostatic expansion valve
bypass assembly option between the distributor sideport and the check valve. When the thermostatic expansion
valve bypass assembly is shipped-loose, the installer will need to position the remote bulb. When the thermostatic
expansion valve bypass assembly is factory-installed, the remote bulb should already be properly installed.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
3-Pipe Hot Gas Defrost
The hot gas defrost unit coolers conforms to
the standard 3-pipe hot gas system using a check
valve assembly, an electrical control to terminate
the defrost, and a hot gas solenoid valve. The
check valve assembly transports the hot gas
between the drain pan loop and the sideport
distributor of the coil. The check valve assembly kit
is available for shipped-loose or factory-installed
for an additional cost.
The electrical control option includes an
adjustable defrost termination and fan delay
control (DTFD) which is standard. An optional
(2) control electrical system is available with one
adjustable control for defrost termination (DT)
and one fixed control for the fan delay (FD) for
an additional cost. For both the DTFD and DT
adjustable controls, the remote bulb position is
with the bulb strapped to the suction line to insure
a complete defrost. The remote bulb is positioned
by the installer. The hot gas solenoid valve must be
ordered separately and will be shipped-loose. The thermostatic expansion valve could be ordered separately and shipped-
loose or the thermostatic expansion valve could be factory-installed with a liquid line for an additional cost.
The liquid line is designed for the body styles of the Sporlan SQE, SBF, EG and the Alco HFESC thermostatic
expansion valves. The thermostatic expansion valve needs to be selected by the sales engineer. In a typical 3-
pipe, multiple evaporator system, the compressor discharge defrosts the evaporator. The liquid/vapor mixture of
refrigerant after defrost, however, returns to the common suction line of the system. In order to provide sufficient
re-evaporation of the liquid vapor mixture and sufficient heat for defrost, no more than one-third of the system
should be defrosted at one time. Some means of control in the 3-pipe hot gas system should be supplied to
regulate the large amount of liquid returning to the compressor, refrigerant slugging can otherwise damage
the compressor.
Shipped-loose
TXV Liquid Line
EG
Factory-installed
TXV Liquid Line
EG
GLC 6 FPI
SQE/SBF
HFESC
SQE/SBF
HFESC
035-075
090-160
180-280
50169410
50169411
50169412
50169413
50169414
50169415
50169416
50169417
50169418
52733901
52733902
52733903
52733904
52733905
52733906
52733907
52733908
52733909
GLC 4 FPI
041-080
102-204
235
50169410
50169411
50169412
50169413
50169414
50169415
50169416
50169417
50169418
52733901
52733902
52733903
52733904
52733905
52733906
52733907
52733908
52733909
For hot gas models with the
hot gas loop drain pan only
Shipped-loose
Factory-installed
Drain Pan Loop Check Valve Kit Drain Pan Loop Check Valve Kit
When using the hot
GLC 6 FPI
gas units with a hot
gas loop drain pan on
0°F applications and
below, an insulated
drain pan is required.
035-075
090-160
180-280
50169504
50169505
50169506
52739601
52739602
52739603
GLC 4 FPI
041-080
102-204
235
50169504
50169505
50169506
52739601
52739602
52739603
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacement Parts
Commercial Refrigeration Parts
Right source. Right parts. Right now.
Hot Gas Defrost - Electric Drain Pan
Option Drain Pan Heater (1 per unit)
InterLink™ is your link to a complete line of dependable and certified
commercial refrigeration parts, accessories and innovative electronic
controls for all Chandler equipment. At InterLink, we provide our
wholesalers with a comprehensive selection of product solutions and
innovative technologies for the installed customer base. And every
product is built to ensure the same high performance standards with
which all Heatcraft Refrigeration Products (HRP) brands are built
— backed by a dedicated team to serve every customer need, delivering
at the best lead times in the industry.
Part #
Description
Voltage
No. Fans
24752101 300 W
24752102 600 W
24752103 900 W
24752104 1200 W
24752105 1500 W
24752106 1800 W
24752201 300 W
24752202 600 W
24752203 900 W
24752204 1200 W
24752205 1500 W
24752206 1800 W
24752301 300 W
24752302 600 W
24752303 900 W
24752304 1200 W
24752305 1500 W
24752306 1800 W
115/1/60
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
115/1/60
115/1/60
115/1/60
115/1/60
115/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
460/1/60
460/1/60
460/1/60
460/1/60
460/1/60
Dependable. Versatile. Courteous.
Finally, one simple source for all your replacement needs from a name
you can trust.
Air Defrost
6 FPI
040-065
070-130
140-180
208
Electric & Hot Gas Defrost
No. Fans
6 FPI
035-047
065-090
120-140
160-180
200
4 FPI
1
2
3
4
5
6
041
068-080
102
136
460/1/60
260
312-370
170
240-280
204-235
Electric Defrost
Motor/Fan Blade/Fan Guards
Part #
Description
Voltage
No. Fans
Part #
Description
No. Fans
Coil Heater
25300101 Motor 115/1/60 Shaded Pole
25300201 Motor 208-230/1/60 Shaded Pole
25309501 Motor 115/1/60/50 Totally Enclosed PSC/PSC
25309601 Motor 208-230/1/60/50 Totally Enclosed PSC
25309701 Motor 460/1/60/50 Totally Enclosed PSC
25309801 Motor 208-230/1/60/50 PSC
25308701 Motor 460/1/60/50 PSC
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
24752001 300 W
24752002 600 W
24752003 900 W
24752004 1200 W
24752005 1500 W
24752006 1800 W
Bottom Coil Heater
24752401 150 W
24752402 300 W
24752403 450 W
24752404 600 W
24752405 750 W
24752406 900 W
Drain Pan Heater
24752501 150 W
24752502 300 W
24752503 450 W
24752504 600 W
24752505 750 W
24752506 900 W
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
1
2
3
4
5
6
25317701 Motor 208-230/1/60 EC
25317801 Motor 115/1/60 EC
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
1
2
3
4
5
6
5140C
Fan Blade
37000701 Fan Guard - Molded
37000601 Fan Guard - Wire
23104901 Motor Mount used with 115 & 230V motors
23103301 Motor Mount used with 460V motors
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
1
2
3
4
5
6
Cabinet Components
Part #
Description
No. Fans
40480101 Drain Pan Air & Hot Gas Defrost
40480201 Drain Pan Air & Hot Gas Defrost
40480301 Drain Pan Air & Hot Gas Defrost
40480401 Drain Pan Air & Hot Gas Defrost
40480501 Drain Pan Air & Hot Gas Defrost
40480601 Drain Pan Air & Hot Gas Defrost
40480103 Drain Pan Electric Defrost
40480205 Drain Pan Electric Defrost
40480305 Drain Pan Electric Defrost
40480403 Drain Pan Electric Defrost
40480503 Drain Pan Electric Defrost
40480603 Drain Pan Electric Defrost
40880801 Access Panel - Elect.
1
2
3
4
5
6
1
2
3
4
5
6
1 - 6
1 - 6
1 - 6
1 - 6
1 - 6
Electrical Components
Part #
22512601 Terminal Strip
Description
No. Fans
1 - 6
Defrost Termination/Fan Delay
— Klixon type
5709L
1 - 6
1 - 6
Defrost Termination/Fan Delay
— Adjustable type
4267W
2891040
5708L
Room Thermostat
Heater Safety — Klixon type
1 - 6
1 - 6
40880701 Access Panel - Refrig.
40880901 Back Panel - Refrig.
40881001 Back Panel - Elect.
40881201 End Panel - Hot Gas Refrig.
Drain Fittings
Part #
26925101 Drain Fitting Kit
Description
No. Fans
1 - 6
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Nozzle Selection
Model RLC Air Defrost
No. of
No. of
Circuits
Distributor Tube (in.)
Model
R-404A
R-22
Fans
OD
Length
15
RLC040
RLC052
RLC065
RLC070
RLC090
RLC104
RLC120
RLC130
RLC140
RLC156
RLC180
RLC208
RLC260
RLC312
RLC370
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
1
1
2
2
3
3
3
4
4
5
5
5
9
9
10
-
-
-
-
15
15
15
15
15
15
15
15
15
15
15
15
15
15
L-1/2
L-1/2
L-3/4
L-3/4
L-1
L-1
L-1
L-1-1/2
L-1-1/2
L-1-1/2
L-2
L-2-1/2
L-3
L-1/3
L-1/3
L-1/2
L-1/2
L-3/4
L-3/4
L-3/4
L-1
L-1
L-1
L-1-1/2
L-2
L-2
Model ELC/EFC Electric Defrost
Low Temp.
-30°F to 0°F SST
-34°C to -18°C SST
Medium Temp.
10°F to 25°F SST
-12°C to -4°C SST
No. of
Fans
No. of
Distributor Tube (in.)
Model
Circuits
OD
Length
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
R-404A
L-1/2
L-1/2
L-1/2
L-3/4
L-1
R-22
L-1/4
L-1/4
L-1/3
L-1/2
L-3/4
L-3/4
L-1
R-404A
R-22
L-1/4
L-1/4
L-1/3
L-1/2
L-1/2
L-1/2
L-3/4
L-1
ELC035
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
3/16
2
2
2
4
4
5
5
6
8
10
9
9
10
2
4
4
5
8
8
L-1/3
L-1/3
L-1/3
L-1/2
L-3/4
L-3/4
L-1
L-1-1/2
L-1-1/2
L-1-1/2
L-2
ELC040
ELC047
ELC065
ELC075
ELC090
ELC120
ELC140
ELC160
ELC180
ELC200
ELC240
ELC280
EFC041
EFC068
EFC080
EFC102
EFC136
EFC170
EFC204
EFC235
L-1
L-1-1/2
L-1-1/2
L-2
L-1
L-1
L-1
L-1
L-2
L-1-1/2
L-1-1/2
L-2
L-2-1/2
L-2-1/2
L-3
L-1-1/2
L-1-1/2
L-2
L-1/4
L-1/3
L-1/2
L-3/4
L-3/4
L-1
L-2
L-2
L-2-1/2
L-1/3
L-1/2
L-3/4
L-3/4
L-1
L-1/2
L-3/4
L-1
L-1/3
L-1/2
L-3/4
L-3/4
L-1
L-1-1/2
L-1-1/2
L-2
L-1
L-1-1/2
L-2
L-2-1/2
L-2-1/2
L-1-1/2
L-2
8
10
L-1-1/2
L-1-1/2
L-2
Model GLC Hot Gas Defrost
Low Temp.
-30°F to 0°F SST
-34°C to -18°C SST
Medium Temp.
10°F to 25°F SST
-12°C to -4°C SST
No. of
Circuits
Distributor Tube (in.)
Model
No. of Fans
OD
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
1/4
Length
15
R-404A
J-1/2
J-1/2
J-3/4
J-1
R-22
J-1/4
J-1/3
J-1/3
J-1/2
J-3/4
G-3/4
G-1
R-404A
R-22
J-1/4
J-1/4
J-1/4
J-1/3
J-1/2
G-1/2
G-3/4
G-1
GLC035
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
2
2
2
4
4
5
5
6
8
10
9
9
10
2
4
4
5
8
8
J-1/3
J-1/3
J-1/2
J-3/4
J-3/4
G-3/4
G-1
GLC040
GLC047
GLC065
GLC075
GLC090
GLC120
GLC140
GLC160
GLC180
GLC200
GLC240
GLC280
GLC041
GLC068
GLC080
GLC102
GLC136
GLC170
GLC204
GLC235
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
J-1
G-1-1/2
G-1-1/2
G-2
G-1
G-1-1/2
G-1-1/2
E-1-1/2
E-2
G-2
G-1-1/2
E-1-1/2
E-2
G-1
E-1
E-2-1/2
E-2-1/2
E-3
E-1-1/2
E-1-1/2
E-2
J-1/4
J-1/2
J-1/2
G-3/4
G-1
E-2
E-2
E-4
E-2-1/2
J-1/3
J-1/2
J-3/4
G-3/4
G-1
E-2-1/2
J-1/3
J-3/4
J-3/4
G-1
G-1-1/2
G-1-1/2
G-2
J-1/2
J-1
J-1
G-1-1/2
G-2
15
15
15
15
G-2
G-1-1/2
G-2
G-1
G-1-1/2
E-1-1/2
8
10
G-2-1/2
E-3
E-2
E-2
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
19
Download from Www.Somanuals.com. All Manuals Search And Download.
For more information on Chandler refrigeration products, contact
A Brand of Heatcraft Refrigeration Products LLC
2175 West Park Place Blvd. • Stone Mountain, GA • 30087
800-321-1881 • FAX 770-465-5990
Since product improvement is a continuing effort, we reserve the right to make
changes in specifications without notice.
CH-LOPTB-0508 | Version 000
Download from Www.Somanuals.com. All Manuals Search And Download.
|