Heatcraft Refrigeration Products Fan ELC EFC User Manual

CH-LOPTB  
May, 2008  
Replaces CH-B-15B, March 2004y  
2007  
LOW PROFILE  
UNIT COOLER  
Technical Guide  
Models RLC | Air Defrost  
ELC/EFC | Electric Defrost  
GLC | Hot Gas Defrost  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features & Benefits  
Cabinet  
• Minimal height of the low profile series makes it ideal for low ceiling coolers  
• Cabinet design features front access panels on each side for easy access to electrical and refrigeration components  
• All electrical components factory wired to terminal board and identified, making it easy to field wire the unit  
• Sweat connections to reduce potential for leaks  
• Internal panels are isolated for quiet operation  
• Liquid line solenoid wire harness is factory-installed for quick installation  
• Pre-drilled holes on the back of the unit for room thermostat  
Coil  
• Internally enhanced tubing and fin design for higher efficiency  
• Coil heater slots have been enlarged for easier installation and replacement  
• Reduced heater wattages  
• Hot gas loop on bottom of coil for easier access is standard for hot gas defrost models  
• Fixed defrost termination for electric, adjustable defrost termination for hot gas  
Drain Pan  
• Large diameter drain hole (3/4" ID) is located on the back of the unit  
• Extended drain pan heaters for more uniform defrost throughout the drain pan and additional heat in  
end compartments  
• On 4-6 fan models, drain pan has a lanyard for easy and safe access  
Motors  
• Motors plug into wiring harness for easier servicing  
• EC motors available factory-installed or as a drop-in replacement through InterLink™ Commercial Refrigeration Parts in  
115/1/60, 208-230/1/60 and 208-230/3/60 unit voltages  
• PSC and PSC (Totally Enclosed) motors for 115/1/60, 208-230/1/60 and 460/1/60 unit voltages  
• PSC motors or EC motors required for 50 Hz operation  
Options  
• Unit Configurations: mounted components, pre-assembled, pre-charged and Beacon II™  
- Units available with mounted TXV and mounted TXV / solenoid valve  
- Pre-assembled units come with mounted TXV, liquid line solenoid valve and room thermostat. Available in a master  
liquid line configuration  
- Pre-charged units come with mounted TXV, liquid line solenoid valve, room thermostat and quick connect fittings  
- Various room thermostat variations including rear mount and front access versions  
- Beacon II units come with electronic expansion valves, pressure transducer, temperature sensors and Beacon  
control board  
• Units available with stainless steel housing and drain pan  
Units available with copper fins. Air defrost units also available with polyester coated fins or various coil coatings options  
• Units available with insulated drain pan  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Model RLC Air Defrost | 60 Hz  
Capacity  
Fan Data  
10°F TD  
25°F SST  
6°C TD  
Model  
No.  
CFM  
m3H  
-4°C SST  
Watts  
1,170  
1,520  
1,900  
2,050  
2,640  
3,050  
3,500  
3,810  
4,100  
4,570  
5,270  
6,100  
7,620  
9,140  
10,840  
BTUH  
4,000  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
730  
1,240  
1,189  
1,104  
2,481  
2,379  
2,379  
2,209  
2,209  
3,568  
3,568  
3,313  
4,758  
5,522  
6,627  
6,627  
5,200  
700  
6,500  
650  
7,000  
1,460  
1,400  
1,400  
1,300  
1,300  
2,100  
2,100  
1,950  
2,800  
3,250  
3,900  
3,900  
9,000  
10,400  
12,000  
13,000  
14,000  
15,600  
18,000  
20,800  
26,000  
31,200  
37,000  
Model RLC Air Defrost | 50 Hz †  
Capacity  
Fan Data  
10°F TD  
25°F SST  
6°C TD  
-4°C SST  
Model  
No.  
CFM  
m3H  
BTUH  
3,800  
Watts  
1,112  
1,445  
1,807  
1,946  
2,502  
2,891  
3,335  
3,613  
3,891  
4,336  
5,003  
5,781  
7,226  
8,672  
10,284  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
670  
1,117  
1,070  
995  
4,940  
630  
6,175  
586  
6,650  
1,315  
1,260  
1,260  
1,170  
1,170  
1,891  
1,891  
1,756  
2,521  
2,927  
3,512  
3,512  
2,234  
2,142  
2,142  
1,989  
1,989  
3,213  
3,213  
2,984  
4,284  
4,973  
5,967  
5,967  
8,550  
9,880  
11,400  
12,350  
13,300  
14,820  
17,100  
19,760  
24,700  
29,640  
35,150  
For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will  
not see a reduction in performance due to the electronic control of the motor)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Model RLC Air Defrost | 60 Hz  
Shaded Pole Motor  
PSC, PSC-TE Motor  
208-230/1/60  
EC Motor  
Model  
HP  
115/1/60  
208-230/1/60  
115/1/60  
460/1/60  
115/1/60  
208-230/1/60  
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1.8  
1.8  
1.8  
3.6  
3.6  
3.6  
3.6  
3.6  
5.4  
5.4  
5.4  
7.2  
9.0  
116  
116  
116  
232  
232  
232  
232  
232  
348  
348  
348  
464  
580  
1.0  
1.0  
1.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.0  
3.0  
3.0  
4.0  
5.0  
6.0  
6.0  
122  
122  
122  
244  
244  
244  
244  
244  
366  
366  
366  
488  
610  
732  
732  
1.0  
1.0  
1.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.0  
3.0  
3.0  
4.0  
5.0  
6.0  
6.0  
82  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.0  
1.0  
1.5  
1.5  
1.5  
2.0  
2.5  
3.0  
3.0  
91  
0.4  
0.4  
0.4  
0.8  
0.8  
0.8  
0.8  
0.8  
1.2  
1.2  
1.2  
1.6  
2.0  
2.4  
2.4  
117  
117  
117  
234  
234  
234  
234  
234  
351  
351  
351  
468  
585  
702  
702  
0.9  
0.9  
0.9  
1.8  
1.8  
1.8  
1.8  
1.8  
2.7  
2.7  
2.7  
3.6  
4.5  
5.4  
5.4  
57  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.0  
1.0  
1.5  
1.5  
1.5  
2.0  
2.5  
3.0  
3.0  
59  
82  
91  
57  
59  
82  
91  
57  
59  
164  
164  
164  
164  
164  
246  
246  
246  
328  
410  
492  
492  
182  
182  
182  
182  
182  
273  
273  
273  
364  
455  
546  
546  
114  
114  
114  
114  
114  
171  
171  
171  
228  
285  
342  
342  
118  
118  
118  
118  
118  
177  
177  
177  
236  
295  
354  
354  
1/15 10.8 696  
1/15 10.8 696  
Model RLC Air Defrost | 50 Hz  
PSC Motor  
220/1/50  
EC Motor  
Model  
HP  
110/1/50  
380/1/50  
110/1/50  
220/1/50  
Amps  
Watts  
68  
Amps  
Watts  
Amps  
0.4  
0.4  
0.4  
0.8  
0.8  
0.8  
0.8  
0.8  
1.2  
1.2  
1.2  
1.6  
2.0  
2.4  
2.4  
Watts  
82  
Amps  
Watts  
Amps  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.0  
1.0  
1.5  
1.5  
1.5  
2.0  
2.5  
3.0  
3.0  
Watts  
59  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1.0  
1.0  
1.0  
2.0  
2.0  
2.0  
2.0  
2.0  
3.0  
3.0  
3.0  
4.0  
5.0  
6.0  
6.0  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.0  
1.0  
1.5  
1.5  
1.5  
2.0  
2.5  
3.0  
3.0  
65  
0.9  
0.9  
0.9  
1.8  
1.8  
1.8  
1.8  
1.8  
2.7  
2.7  
2.7  
3.6  
4.5  
5.4  
5.4  
57  
68  
65  
82  
57  
59  
68  
65  
82  
57  
59  
136  
136  
136  
136  
136  
204  
204  
204  
272  
340  
408  
408  
130  
130  
130  
130  
130  
195  
195  
195  
260  
325  
390  
390  
164  
164  
164  
164  
164  
246  
246  
246  
328  
410  
492  
492  
114  
114  
114  
114  
114  
171  
171  
171  
228  
285  
342  
342  
118  
118  
118  
118  
118  
177  
177  
177  
236  
295  
354  
354  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Model ELC/EFC Electric Defrost | 60 Hz  
Capacity  
Fan Data  
10°F TD  
-20°F SST  
BTUH  
6°C TD  
-29°C SST  
Watts  
Model  
No.  
CFM  
m3H  
ELC035  
3,500  
4,000  
4,700  
6,500  
7,500  
1,025  
1,170  
1,380  
1,900  
2,200  
2,640  
3,520  
4,100  
4,690  
5,280  
5,860  
7,030  
8,200  
1,200  
2,000  
2,340  
2,990  
3,990  
4,980  
5,980  
6,880  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
700  
700  
650  
1,189  
1,189  
1,104  
2,379  
2,209  
2,209  
3,568  
3,313  
4,418  
4,418  
5,522  
6,627  
6,627  
1,172  
2,345  
2,345  
3,687  
4,690  
5,862  
7,035  
7,035  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
1,400  
1,300  
1,300  
2,100  
1,950  
2,600  
2,600  
3,250  
3,900  
3,900  
690  
1,380  
1,380  
2,170  
2,760  
3,450  
4,140  
4,140  
Capacity Correction Factors For  
Electric and Hot Gas Defrost Units  
Saturated Suction  
+20 -10 -20 -30  
Temperature °F  
9,000  
12,000  
14,000  
16,000  
18,000  
20,000  
24,000  
28,000  
4,100  
Saturated Suction  
Temperature °C  
-7  
-23 -29 -34  
Multiply Capacity  
By  
1.15 1.04 1.00 0.90  
6,800  
8,000  
10,200  
13,600  
17,000  
20,400  
23,500  
Model ELC/EFC Electric Defrost | 50 Hz †  
Capacity  
Fan Data  
10°F TD  
-20°F SST  
BTUH  
6°C TD  
-29°C SST  
Watts  
Model  
No.  
CFM  
m3H  
ELC035  
3,325  
3,800  
4,465  
6,175  
7,125  
974  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
630  
630  
586  
1,070  
1,070  
995  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
1,113  
1,308  
1,809  
2,087  
2,504  
3,339  
3,896  
4,452  
5,009  
5,565  
6,678  
7,791  
1,141  
1,892  
2,226  
2,838  
3,784  
4,731  
5,677  
6,539  
1,260  
1,170  
1,170  
1,891  
1,756  
2,341  
2,341  
2,927  
3,512  
3,512  
621  
1,243  
1,243  
1,954  
2,485  
3,107  
3,728  
3,728  
2,142  
1,989  
1,989  
3,213  
2,984  
3,978  
3,978  
4,973  
5,967  
5,967  
1,056  
2,111  
2,111  
3,320  
4,223  
5,279  
6,334  
6,334  
8,550  
11,400  
13,300  
15,200  
17,100  
19,000  
22,800  
26,600  
3,895  
6,460  
7,600  
9,690  
12,920  
16,150  
19,380  
22,325  
For EC motors, use 60 Hz capacity and airflow values (Units with EC motors  
operating at 50 Hz will not see a reduction in performance due to the electronic  
control of the motor)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Model ELC/EFC Electric Defrost | 60 Hz  
Shaded Pole Motor  
208-230/1/60  
PSC, PSC-TE Motor  
EC Motor  
208-230/1/60  
Defrost Heaters  
208-230/1/60  
460/1/60  
230/1/60  
230/3/60  
Total Amps  
2.3  
460/1/60  
Model  
HP  
Watts  
Amps  
1.0  
1.0  
1.0  
2.0  
2.0  
2.0  
3.0  
3.0  
4.0  
4.0  
5.0  
6.0  
6.0  
1.0  
2.0  
2.0  
3.0  
4.0  
5.0  
6.0  
6.0  
Watts  
122  
122  
122  
244  
244  
244  
366  
366  
488  
488  
610  
732  
732  
122  
244  
244  
366  
488  
610  
732  
732  
Amps Watts Amps Watts Amps Watts  
ELC035  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.5  
1.5  
2.0  
2.0  
2.5  
3.0  
3.0  
0.5  
1.0  
1.0  
1.5  
2.0  
2.5  
3.0  
3.0  
91  
91  
91  
0.4  
0.4  
0.4  
0.8  
0.8  
0.8  
1.2  
1.2  
1.6  
1.6  
2.0  
2.4  
2.4  
0.4  
0.8  
0.8  
1.2  
1.6  
2.0  
2.4  
2.4  
117  
117  
117  
234  
234  
234  
351  
351  
468  
468  
585  
702  
702  
117  
234  
234  
351  
468  
585  
702  
702  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.5  
1.5  
2.0  
2.0  
2.5  
3.0  
3.0  
0.5  
1.0  
1.0  
1.5  
2.0  
2.5  
3.0  
3.0  
59  
59  
59  
900  
900  
900  
3.9  
3.9  
2.0  
2.0  
2.0  
3.9  
3.9  
3.9  
5.9  
5.9  
7.8  
7.8  
9.8  
11.7  
11.7  
2.0  
3.9  
3.9  
5.9  
7.8  
9.8  
11.7  
11.7  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
2.3  
3.9  
2.3  
182  
182  
182  
273  
273  
364  
364  
455  
546  
546  
91  
182  
182  
273  
364  
455  
546  
546  
118  
118  
118  
177  
177  
236  
236  
295  
354  
354  
59  
118  
118  
177  
236  
295  
354  
354  
1,800  
1,800  
1,800  
2,700  
2,700  
3,600  
3,600  
4,500  
5,400  
5,400  
900  
1,800  
1,800  
2,700  
3,600  
4,500  
5,400  
5,400  
7.8  
4.5  
7.8  
4.5  
7.8  
4.5  
11.7  
11.7  
15.7  
15.7  
19.6  
23.5  
23.5  
3.9  
6.8  
6.8  
9.0  
9.0  
11.3  
13.6  
13.6  
2.3  
7.8  
4.5  
7.8  
4.5  
11.7  
15.7  
19.6  
23.5  
23.5  
6.8  
9.0  
11.3  
13.6  
13.6  
Model ELC/EFC Electric Defrost | 50 Hz  
PSC Motor  
EC Motor  
220/1/50  
Defrost Heaters  
220/1/50 220/3/50 380/1/50  
220/1/50  
380/1/50  
Model  
HP  
Watts  
Amps  
Watts  
Amps  
0.4  
0.4  
0.4  
0.8  
0.8  
0.8  
1.2  
1.2  
1.6  
1.6  
2.0  
2.4  
2.4  
0.4  
0.8  
0.8  
1.2  
1.6  
2.0  
2.4  
2.4  
Watts  
Amps  
Watts  
Total Amps  
ELC035  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
1/15  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.5  
1.5  
2.0  
2.0  
2.5  
3.0  
3.0  
0.5  
1.0  
1.0  
1.5  
2.0  
2.5  
3.0  
3.0  
65  
65  
65  
82  
82  
82  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.5  
1.5  
2.0  
2.0  
2.5  
3.0  
3.0  
0.5  
1.0  
1.0  
1.5  
2.0  
2.5  
3.0  
3.0  
59  
59  
59  
823  
823  
823  
3.7  
3.7  
3.7  
7.5  
7.5  
2.2  
2.2  
2.2  
4.3  
4.3  
4.3  
6.5  
6.5  
8.6  
1.6  
1.6  
1.6  
3.2  
3.2  
3.2  
4.9  
4.9  
6.5  
6.5  
8.1  
9.7  
9.7  
1.6  
3.2  
3.2  
4.9  
6.5  
8.1  
9.7  
9.7  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
130  
130  
130  
195  
195  
260  
260  
325  
390  
390  
65  
130  
130  
195  
260  
325  
390  
390  
164  
164  
164  
246  
246  
328  
328  
410  
492  
492  
82  
164  
164  
246  
328  
410  
492  
492  
118  
118  
118  
177  
177  
236  
236  
295  
354  
354  
59  
118  
118  
177  
236  
295  
354  
354  
1,647  
1,647  
1,647  
2,470  
2,470  
3,294  
3,294  
4,117  
4,941  
4,941  
823  
1,647  
1,647  
2,470  
3,294  
4,117  
4,941  
4,941  
7.5  
11.2  
11.2  
15.0  
15.0  
18.7  
22.5  
22.5  
3.7  
8.6  
10.8  
13.0  
13.0  
2.2  
4.3  
4.3  
6.5  
8.6  
10.8  
13.0  
13.0  
7.5  
7.5  
11.2  
15.0  
18.7  
22.5  
22.5  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Model GLC Hot Gas Defrost | 60 Hz  
Capacity  
Fan Data  
CFM  
10°F TD  
-20°F SST  
6°C TD  
-29°C SST  
Model  
No.  
m3H  
BTUH  
3,500  
4,000  
4,700  
6,500  
Watts  
1,025  
1,170  
1,380  
1,900  
2,200  
2,640  
3,520  
4,100  
4,690  
5,280  
5,860  
7,030  
8,200  
1,200  
2,000  
2,340  
2,990  
3,990  
4,980  
5,980  
6,880  
GLC035  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
700  
700  
650  
1,189  
1,189  
1,104  
2,379  
2,209  
2,209  
3,568  
3,313  
4,418  
4,418  
5,522  
6,627  
6,627  
1,172  
2,345  
2,345  
3,687  
4,690  
5,862  
7,035  
7,035  
GLC040  
GLC047  
GLC065  
GLC075  
GLC090  
GLC120  
GLC140  
GLC160  
GLC180  
GLC200  
GLC240  
GLC280  
GLC041  
GLC068  
GLC080  
GLC102  
GLC136  
GLC170  
GLC204  
GLC235  
1,400  
1,300  
1,300  
2,100  
1,950  
2,600  
2,600  
3,250  
3,900  
3,900  
690  
1,380  
1,380  
2,170  
2,760  
3,450  
4,140  
4,140  
Capacity Correction Factors For  
Electric and Hot Gas Defrost Units  
Saturated Suction  
+20 -10 -20 -30  
Temperature °F  
7,500  
9,000  
12,000  
14,000  
16,000  
18,000  
20,000  
24,000  
28,000  
4,100  
Saturated Suction  
Temperature °C  
-7  
-23 -29 -34  
Multiply Capacity  
By  
1.15 1.04 1.00 0.90  
6,800  
8,000  
10,200  
13,600  
17,000  
20,400  
23,500  
NOTE: When using the hot gas units with a hot gas  
loop drain pan on 0°F applications and below, an  
insulated drain pan is required.  
Model GLC Hot Gas Defrost | 50 Hz †  
Capacity  
Fan Data  
CFM  
10°F TD  
-20°F SST  
6°C TD  
-29°C SST  
Model  
No.  
m3H  
BTUH  
3,325  
3,800  
4,465  
6,175  
7,125  
8,550  
11,400  
1,950  
2,600  
2,600  
3,250  
3,900  
3,900  
690  
1,380  
1,380  
2,170  
2,760  
3,450  
4,140  
4,140  
Watts  
974  
GLC035  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
630  
630  
586  
1,070  
1,070  
995  
GLC040  
GLC047  
GLC065  
GLC075  
GLC090  
GLC120  
GLC140  
GLC160  
GLC180  
GLC200  
GLC240  
GLC280  
GLC041  
GLC068  
GLC080  
GLC102  
GLC136  
GLC170  
GLC204  
GLC235  
1,113  
1,308  
1,809  
2,087  
2,504  
3,339  
3,313  
4,418  
4,418  
5,522  
6,627  
6,627  
1,172  
2,345  
2,345  
3,687  
4,690  
5,862  
7,035  
7,035  
1,260  
1,170  
1,170  
1,891  
1,756  
2,341  
2,341  
2,927  
3,512  
3,512  
621  
1,243  
1,243  
1,954  
2,485  
3,107  
3,728  
3,728  
2,142  
1,989  
1,989  
3,213  
2,984  
3,978  
3,978  
4,973  
5,967  
5,967  
1,056  
2,111  
2,111  
3,320  
4,223  
5,279  
6,334  
6,334  
For EC motors, use 60 Hz capacity and airflow values (Units with EC motors  
operating at 50 Hz will not see a reduction in performance due to the electronic  
control of the motor)  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Model GLC Hot Gas Defrost | 60 Hz  
Shaded Pole Motor  
PSC, PSC-TE Motor  
EC Motor  
Drain Pan Heaters*  
115/1/60 230/1/60 460/1/60  
Total Amps  
208-  
115/1/60  
208-  
208-  
230/1/60  
Model  
HP  
115/1/60  
460/1/60 115/1/60  
230/1/60  
230/1/60  
Watts  
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts  
GLC035 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59  
GLC040 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59  
GLC047 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59  
300  
300  
300  
2.6  
2.6  
2.6  
5.2  
5.2  
5.2  
7.8  
7.8  
10.4  
10.4  
13.0  
15.7  
15.7  
2.6  
5.2  
5.2  
7.8  
1.3  
1.3  
1.3  
2.6  
2.6  
2.6  
3.9  
3.9  
5.2  
5.2  
6.5  
7.8  
7.8  
1.3  
2.6  
2.6  
3.9  
5.2  
6.5  
7.8  
7.8  
0.7  
0.7  
0.7  
1.3  
1.3  
1.3  
2.0  
2.0  
2.6  
2.6  
3.3  
3.9  
3.9  
0.7  
1.3  
1.3  
2.0  
2.6  
3.3  
3.9  
3.9  
GLC065 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600  
GLC075 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600  
GLC090 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600  
GLC120 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900  
GLC140 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900  
GLC160 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200  
GLC180 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200  
GLC200 1/15 9.0 580 5.0 610 5.0 410 2.5 455 2.0 585 4.7 285 2.6 295 1,500  
GLC240 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800  
GLC280 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800  
GLC041 1/15 1.8 116 1.0 122 1.0 82 0.5 91 0.4 117 1.1 57 0.6 59  
300  
GLC068 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600  
GLC080 1/15 3.6 232 2.0 244 2.0 164 1.0 182 0.8 234 2.0 114 1.1 118 600  
GLC102 1/15 5.4 348 3.0 366 3.0 246 1.5 273 1.2 351 2.9 171 1.6 177 900  
GLC136 1/15 7.2 464 4.0 488 4.0 328 2.0 364 1.6 468 3.8 228 2.1 236 1,200  
GLC170 1/15 9.0 580 5.0 610 5.0 410 2.5 455 2.0 585 4.7 285 2.6 295 1,500  
GLC204 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800  
GLC235 1/15 10.8 696 6.0 732 6.0 492 3.0 546 2.4 702 5.6 342 3.1 354 1,800  
10.4  
13.0  
15.7  
15.7  
Model GLC Hot Gas Defrost | 50 Hz  
PSC Motor  
220/1/50  
EC Motor  
Drain Pan Heaters*  
Model  
HP  
110/1/50  
380/1/50  
110/1/50  
220/1/50  
110/1/50 220/3/50 380/1/50  
Total Amps  
Watts  
Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts  
GLC035 1/15 1.0  
GLC040 1/15 1.0  
GLC047 1/15 1.0  
GLC065 1/15 2.0  
GLC075 1/15 2.0  
GLC090 1/15 2.0  
GLC120 1/15 3.0  
GLC140 1/15 3.0  
GLC160 1/15 4.0  
GLC180 1/15 4.0  
GLC200 1/15 5.0  
GLC240 1/15 6.0  
GLC280 1/15 6.0  
GLC041 1/15 1.0  
GLC068 1/15 2.0  
GLC080 1/15 2.0  
GLC102 1/15 3.0  
GLC136 1/15 4.0  
GLC170 1/15 5.0  
GLC204 1/15 6.0  
GLC235 1/15 6.0  
68  
68  
68  
0.5  
0.5  
0.5  
1.0  
1.0  
1.0  
1.5  
1.5  
2.0  
2.0  
2.5  
3.0  
3.0  
0.5  
1.0  
1.0  
1.5  
2.0  
2.5  
3.0  
3.0  
65  
65  
65  
0.4  
0.4  
0.4  
0.8  
0.8  
0.8  
1.2  
1.2  
1.6  
1.6  
2.0  
2.4  
2.4  
0.4  
0.8  
0.8  
1.2  
1.6  
2.0  
2.4  
2.4  
82  
82  
82  
1.1  
1.1  
1.1  
2.0  
2.0  
2.0  
2.9  
2.9  
3.8  
3.8  
4.7  
5.6  
5.6  
1.1  
2.0  
2.0  
2.9  
3.8  
4.7  
5.6  
5.6  
57  
57  
57  
0.6  
0.6  
0.6  
1.1  
1.1  
1.1  
1.6  
1.6  
2.1  
2.1  
2.6  
3.1  
3.1  
0.6  
1.1  
1.1  
1.6  
2.1  
2.6  
3.1  
3.1  
59  
59  
59  
275  
275  
275  
549  
549  
549  
823  
823  
2.5  
2.5  
2.5  
5.0  
5.0  
5.0  
7.5  
7.5  
10.0  
10.0  
12.5  
15.0  
15.0  
2.5  
5.0  
5.0  
7.5  
1.3  
1.3  
1.3  
2.5  
2.5  
2.5  
3.7  
3.7  
5.0  
5.0  
6.2  
7.5  
7.5  
1.3  
2.5  
2.5  
3.7  
5.0  
6.2  
7.5  
7.5  
0.6  
0.6  
0.6  
1.1  
1.1  
1.1  
1.6  
1.6  
2.2  
2.2  
2.7  
3.2  
3.2  
0.6  
1.1  
1.1  
1.6  
2.2  
2.7  
3.2  
3.2  
136  
136  
136  
204  
204  
272  
272  
340  
408  
408  
68  
136  
136  
204  
272  
340  
408  
408  
130  
130  
130  
195  
195  
260  
260  
325  
390  
390  
65  
130  
130  
195  
260  
325  
390  
390  
164  
164  
164  
246  
246  
328  
328  
410  
492  
492  
82  
164  
164  
246  
328  
410  
492  
492  
114  
114  
114  
171  
171  
228  
228  
285  
342  
342  
57  
114  
114  
171  
228  
285  
342  
342  
118  
118  
118  
177  
177  
236 1,098  
236 1,098  
295 1,372  
354 1,649  
354 1,649  
59  
275  
549  
549  
823  
118  
118  
177  
236 1,098  
295 1,372  
354 1,649  
354 1,649  
10.0  
12.5  
15.0  
15.0  
* Optional with electric drain pan  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Physical Data  
Model RLC Air Defrost  
Approx. Net  
Wt.  
Connections (in.)  
No. of  
Model  
Fans  
Coil Inlet  
OD  
External  
Suction ID  
Drain MPT  
lbs.  
kg  
Equalizer OD  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
5/8  
5/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
1-1/8  
1-1/8  
1-1/8  
1-3/8  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
28  
31  
34  
45  
48  
49  
51  
53  
63  
67  
69  
82  
103  
124  
127  
13  
15  
16  
21  
22  
23  
24  
25  
29  
31  
32  
38  
47  
57  
58  
Model ELC/EFC Electric Defrost  
Approx. Net  
Wt.  
Connections (in.)  
No. of  
Model  
Fans  
Coil Inlet  
OD  
External  
Suction ID  
Drain MPT  
lbs.  
kg  
Equalizer OD  
ELC035  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
1/2  
5/8  
5/8  
5/8  
5/8  
5/8  
7/8  
7/8  
7/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
5/8  
7/8  
7/8  
7/8  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
24  
26  
29  
43  
45  
48  
60  
62  
81  
11  
12  
14  
20  
21  
22  
28  
29  
37  
39  
46  
55  
57  
13  
21  
22  
27  
37  
46  
55  
56  
84  
101  
121  
124  
28  
44  
47  
59  
80  
100  
120  
123  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Physical Data  
Model GLC Hot Gas Defrost  
Approx.  
Net Wt.  
Connections (in.)  
No. of  
Fans  
Model  
Coil  
Inlet  
ODF  
External  
Drain  
Side  
Port  
OD  
Hot Gas  
Suction  
ID  
Equalizer  
MPT  
Pan Conns. lbs. kg  
OD  
OD  
GLC035  
GLC040  
GLC047  
GLC065  
GLC075  
GLC090  
GLC120  
GLC140  
GLC160  
GLC180  
GLC200  
GLC240  
GLC280  
GLC041  
GLC068  
GLC080  
GLC102  
GLC136  
GLC170  
GLC204  
GLC235  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
5/8  
5/8  
5/8  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
26  
28  
31  
45  
47  
50  
62  
64  
83  
86  
103 47  
123 56  
126 57  
30  
46  
49  
61  
82  
12  
13  
15  
21  
22  
23  
29  
30  
38  
40  
5/8  
5/8  
5/8  
5/8  
5/8  
5/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
7/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
5/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
5/8  
14  
21  
23  
28  
38  
5/8  
7/8  
5/8  
7/8  
7/8  
7/8  
7/8  
1-1/8  
1-1/8  
1-1/8  
1-1/8  
7/8  
102 47  
122 56  
125 57  
7/8  
1-1/8  
The standard design for the Chandler Low Profile Evaporator incorporates a hot gas loop in the drain pan. Utilizing  
a hot gas loop is ideal for hot gas defrost applications where high temperature gas can be maintained to defrost  
both the evaporator drain pan and coil.  
For applications where cooler (lower) temperature hot gas is used for defrosting, Chandler offers optional electric  
heater elements in the drain pan to ensure quick and efficient defrost of the drain pan allowing condensate to  
drain quickly, saving the hot gas for efficient evaporator coil defrost.  
If the optional electric heating element drain pan is preferred, please specify when ordering, there is no additional  
charge.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional Data  
Dimensional Data For All Models  
Air  
Defrost  
Model  
Electric and  
Hot Gas  
Defrost Model  
Dimensions  
No.  
of  
Fans  
A
B
C
D
6 FPI  
040  
052  
065  
070  
090  
104  
120  
130  
140  
156  
180  
208  
-
6 FPI  
035  
040  
047  
-
4 FPI  
-
in.  
mm  
in.  
mm  
438.1  
438.1  
438.1  
845  
in.  
-
-
-
-
mm  
in.  
-
-
-
-
-
-
-
-
-
-
-
-
mm  
-
1
1
1
2
2
2
2
2
3
3
3
4
4
5
6
6
29.50  
29.50  
29.50  
749.3  
749.3  
749.3  
17.25  
17.25  
17.25  
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
041  
-
-
45.50 1,155.7 33.25  
45.50 1,155.7 33.25  
45.50 1,155.7 33.25  
45.50 1,155.7 33.25  
45.50 1,155.7 33.25  
61.50 1,562.1 49.25  
61.50 1,562.1 49.25  
61.50 1,562.1 49.25  
77.50 1,968.5 65.25  
77.50 1,968.5 65.25  
93.50 2,374.9 81.25  
109.50 2,781.3 97.25  
109.50 2,781.3 97.25  
-
065  
-
-
845  
-
-
-
845  
-
-
075  
090  
120  
-
068  
080  
102  
-
845  
-
-
845  
-
-
1,251  
1,251  
1,251  
1,657  
1,657  
2,064  
2,470  
2,470  
-
-
-
-
-
-
140  
160  
180  
200  
240  
280  
-
-
-
-
-
136  
170  
204  
235  
-
-
260  
312  
370  
48.63 1,235.1 32.63  
48.63 1,235.1 48.63 1,235.1  
48.63 1,235.1 48.63 1,235.1  
828.7  
NOTE: Hanger brackets will accept 3/8” / 9.5 mm hanger rods.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot Gas Reverse Cycle Kits  
Shipped-loose  
Factory-installed  
TXV Bypass Assembly Kits  
TXV Bypass Assembly Kits  
GLC 6 FPI  
035-075  
090-160  
180-280  
SQE/SBF  
50169210  
50169211  
50169212  
EG  
50169213  
50169214  
50169215  
HFESC  
50169216  
50169217  
50169218  
SQE/SBF  
52733701  
52733702  
52733703  
EG  
52733704  
52733705  
52733706  
HFESC  
52733707  
52733708  
52733709  
GLC 4 FPI  
041-080  
102-204  
235  
50169210  
50169211  
50169212  
50169213  
50169214  
50169215  
50169216  
50169217  
50169218  
52733701  
52733702  
52733703  
52733704  
52733705  
52733706  
52733707  
52733708  
52733709  
Shipped-loose  
Factory-installed  
Drain Pan Loop  
Check Valve Kit  
Suction Line  
Check Valve Kit  
Drain Pan Loop  
Check Valve Kit  
Suction Line  
Check Valve Kit  
GLC 6 FPI  
035-065  
075-140  
160-280  
50169304  
50169305  
50169306  
50169604  
50169605  
50169606  
52733601  
52733602  
52733603  
52733801  
52733802  
52733803  
GLC 4 FPI  
041  
068-102  
136-235  
50169304  
50169305  
50169306  
50169604  
50169605  
50169606  
52733601  
52733602  
52733603  
52733801  
52733802  
52733803  
Recommendation is that both check valve kits are ordered: (For hot gas models with the hot gas loop drain  
pan ONLY)  
NOTE: The drain pan check valve kit can be ordered as an independent item. But the suction line check valve kit  
must be ordered with the drain pan check valve kit in order to complete the piping.  
NOTE: When using the hot gas units with a hot gas loop drain pan on 0°F applications and below, an insulated  
drain pan is required.  
The hot gas unit coolers can be used in reverse cycle hot gas defrost systems using multiple evaporators  
connected to one condensing unit. Generally, not more than one-third of the system defrosts at one time.  
During the reverse cycle defrost, the reversing  
valve; located in the compressor discharge  
line, diverts hot gas through the suction line  
to the evaporator. See piping view in Figure  
1. The suction line check valve directs the hot  
gas through the drain pan loop which prevents  
condensate in the pan from freezing. The hot  
gas exits the loop at the pan loop outlet header  
and enters the evaporator through the check  
valve assembly. As the hot gas defrosts the coil,  
heat is removed from the hot gas and eventually  
it condenses into a liquid and exits the coil at  
the distributor sideport. The liquid then flows  
through the check valve of the thermostatic  
expansion valve bypass assembly, around the  
thermostatic expansion valve, and into the  
system liquid line. The liquid refrigerant then  
feeds other evaporators on the cooling cycle,  
evaporates, and returns to the compressor  
through their suction lines.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hot Gas Reverse Cycle Kits (cont.)  
In the refrigeration cycle, the thermostatic expansion  
valve bypass assembly check valve only allows refrigerant  
flow through the thermostatic expansion valve and into  
the evaporator coil. As the refrigerant vapor exits the coil  
at the suction line, the check valve of the drain pan loop  
check valve assembly prevents the refrigerant vapor flow  
through the drain pan loop.  
Factory engineered assemblies (kits) are available for both  
shipped-loose and factory-installed at an additional cost  
to complete the reverse cycle piping and components.  
The suction line check valve assembly includes the  
suction line check valve and the piping for both the  
suction line and the connection to the drain pan loop  
inlet header. In order for the suction line check valve  
assembly to be mounted, the drain pan loop check  
valve assembly must be used. The drain pan loop check  
valve assembly includes the check valve, suction line  
tee and a bent pipe. The thermostatic expansion valve  
bypass assembly option includes the check valve, tee  
and necessary piping. In order for the thermostatic  
expansion valve bypass assembly option to be complete,  
a thermostatic expansion valve must be selected by the  
sales engineer. The thermostatic expansion valve bypass  
assembly option is dependent on the body style of the  
thermostatic expansion valves which includes the Sporlan  
SQE, SBF, EG and the Alco HFESC body styles. The factory-  
installed thermostatic expansion valve bypass assembly  
option must have the thermostatic expansion valve selection included on the order for the hot gas unit cooler.  
To increase the efficiency, higher performance and greater system protection, a heat exchanger may be  
beneficial to the system. In order to use a heat exchanger, the thermostatic expansion valve bypass assembly  
option must be modified. See the piping view in Figure 2. The modification includes rerouting the pipe from the  
thermostatic expansion valve bypass check valve to the inlet connection of the liquid line to the heat exchanger.  
A pipe needs to be routed from the liquid line outlet connection of the heat exchanger to the inlet connection of  
the thermostatic expansion valve.  
The electrical control option includes an adjustable defrost termination and fan delay control (DTFD) which is  
standard. For an additional cost, an optional (2) control electrical system is available with one adjustable control  
for defrost termination (DT) and one fixed control for the fan delay (FD). For both the DTFD and DT adjustable  
controls, the remote bulb position is with the bulb strapped to the piping of the thermostatic expansion valve  
bypass assembly option between the distributor sideport and the check valve. When the thermostatic expansion  
valve bypass assembly is shipped-loose, the installer will need to position the remote bulb. When the thermostatic  
expansion valve bypass assembly is factory-installed, the remote bulb should already be properly installed.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-Pipe Hot Gas Defrost  
The hot gas defrost unit coolers conforms to  
the standard 3-pipe hot gas system using a check  
valve assembly, an electrical control to terminate  
the defrost, and a hot gas solenoid valve. The  
check valve assembly transports the hot gas  
between the drain pan loop and the sideport  
distributor of the coil. The check valve assembly kit  
is available for shipped-loose or factory-installed  
for an additional cost.  
The electrical control option includes an  
adjustable defrost termination and fan delay  
control (DTFD) which is standard. An optional  
(2) control electrical system is available with one  
adjustable control for defrost termination (DT)  
and one fixed control for the fan delay (FD) for  
an additional cost. For both the DTFD and DT  
adjustable controls, the remote bulb position is  
with the bulb strapped to the suction line to insure  
a complete defrost. The remote bulb is positioned  
by the installer. The hot gas solenoid valve must be  
ordered separately and will be shipped-loose. The thermostatic expansion valve could be ordered separately and shipped-  
loose or the thermostatic expansion valve could be factory-installed with a liquid line for an additional cost.  
The liquid line is designed for the body styles of the Sporlan SQE, SBF, EG and the Alco HFESC thermostatic  
expansion valves. The thermostatic expansion valve needs to be selected by the sales engineer. In a typical 3-  
pipe, multiple evaporator system, the compressor discharge defrosts the evaporator. The liquid/vapor mixture of  
refrigerant after defrost, however, returns to the common suction line of the system. In order to provide sufficient  
re-evaporation of the liquid vapor mixture and sufficient heat for defrost, no more than one-third of the system  
should be defrosted at one time. Some means of control in the 3-pipe hot gas system should be supplied to  
regulate the large amount of liquid returning to the compressor, refrigerant slugging can otherwise damage  
the compressor.  
Shipped-loose  
TXV Liquid Line  
EG  
Factory-installed  
TXV Liquid Line  
EG  
GLC 6 FPI  
SQE/SBF  
HFESC  
SQE/SBF  
HFESC  
035-075  
090-160  
180-280  
50169410  
50169411  
50169412  
50169413  
50169414  
50169415  
50169416  
50169417  
50169418  
52733901  
52733902  
52733903  
52733904  
52733905  
52733906  
52733907  
52733908  
52733909  
GLC 4 FPI  
041-080  
102-204  
235  
50169410  
50169411  
50169412  
50169413  
50169414  
50169415  
50169416  
50169417  
50169418  
52733901  
52733902  
52733903  
52733904  
52733905  
52733906  
52733907  
52733908  
52733909  
For hot gas models with the  
hot gas loop drain pan only  
Shipped-loose  
Factory-installed  
Drain Pan Loop Check Valve Kit Drain Pan Loop Check Valve Kit  
When using the hot  
GLC 6 FPI  
gas units with a hot  
gas loop drain pan on  
0°F applications and  
below, an insulated  
drain pan is required.  
035-075  
090-160  
180-280  
50169504  
50169505  
50169506  
52739601  
52739602  
52739603  
GLC 4 FPI  
041-080  
102-204  
235  
50169504  
50169505  
50169506  
52739601  
52739602  
52739603  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacement Parts  
Commercial Refrigeration Parts  
Right source. Right parts. Right now.  
Hot Gas Defrost - Electric Drain Pan  
Option Drain Pan Heater (1 per unit)  
InterLink™ is your link to a complete line of dependable and certified  
commercial refrigeration parts, accessories and innovative electronic  
controls for all Chandler equipment. At InterLink, we provide our  
wholesalers with a comprehensive selection of product solutions and  
innovative technologies for the installed customer base. And every  
product is built to ensure the same high performance standards with  
which all Heatcraft Refrigeration Products (HRP) brands are built  
— backed by a dedicated team to serve every customer need, delivering  
at the best lead times in the industry.  
Part #  
Description  
Voltage  
No. Fans  
24752101 300 W  
24752102 600 W  
24752103 900 W  
24752104 1200 W  
24752105 1500 W  
24752106 1800 W  
24752201 300 W  
24752202 600 W  
24752203 900 W  
24752204 1200 W  
24752205 1500 W  
24752206 1800 W  
24752301 300 W  
24752302 600 W  
24752303 900 W  
24752304 1200 W  
24752305 1500 W  
24752306 1800 W  
115/1/60  
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
115/1/60  
115/1/60  
115/1/60  
115/1/60  
115/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
460/1/60  
460/1/60  
460/1/60  
460/1/60  
460/1/60  
Dependable. Versatile. Courteous.  
Finally, one simple source for all your replacement needs from a name  
you can trust.  
For parts, please contact (800) 686-7278 or visit www.interlinkparts.com.  
Air Defrost  
6 FPI  
040-065  
070-130  
140-180  
208  
Electric & Hot Gas Defrost  
No. Fans  
6 FPI  
035-047  
065-090  
120-140  
160-180  
200  
4 FPI  
1
2
3
4
5
6
041  
068-080  
102  
136  
460/1/60  
260  
312-370  
170  
240-280  
204-235  
Electric Defrost  
Motor/Fan Blade/Fan Guards  
Part #  
Description  
Voltage  
No. Fans  
Part #  
Description  
No. Fans  
Coil Heater  
25300101 Motor 115/1/60 Shaded Pole  
25300201 Motor 208-230/1/60 Shaded Pole  
25309501 Motor 115/1/60/50 Totally Enclosed PSC/PSC  
25309601 Motor 208-230/1/60/50 Totally Enclosed PSC  
25309701 Motor 460/1/60/50 Totally Enclosed PSC  
25309801 Motor 208-230/1/60/50 PSC  
25308701 Motor 460/1/60/50 PSC  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
24752001 300 W  
24752002 600 W  
24752003 900 W  
24752004 1200 W  
24752005 1500 W  
24752006 1800 W  
Bottom Coil Heater  
24752401 150 W  
24752402 300 W  
24752403 450 W  
24752404 600 W  
24752405 750 W  
24752406 900 W  
Drain Pan Heater  
24752501 150 W  
24752502 300 W  
24752503 450 W  
24752504 600 W  
24752505 750 W  
24752506 900 W  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
1
2
3
4
5
6
25317701 Motor 208-230/1/60 EC  
25317801 Motor 115/1/60 EC  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
1
2
3
4
5
6
5140C  
Fan Blade  
37000701 Fan Guard - Molded  
37000601 Fan Guard - Wire  
23104901 Motor Mount used with 115 & 230V motors  
23103301 Motor Mount used with 460V motors  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
208-230/1/60  
1
2
3
4
5
6
Cabinet Components  
Part #  
Description  
No. Fans  
40480101 Drain Pan Air & Hot Gas Defrost  
40480201 Drain Pan Air & Hot Gas Defrost  
40480301 Drain Pan Air & Hot Gas Defrost  
40480401 Drain Pan Air & Hot Gas Defrost  
40480501 Drain Pan Air & Hot Gas Defrost  
40480601 Drain Pan Air & Hot Gas Defrost  
40480103 Drain Pan Electric Defrost  
40480205 Drain Pan Electric Defrost  
40480305 Drain Pan Electric Defrost  
40480403 Drain Pan Electric Defrost  
40480503 Drain Pan Electric Defrost  
40480603 Drain Pan Electric Defrost  
40880801 Access Panel - Elect.  
1
2
3
4
5
6
1
2
3
4
5
6
1 - 6  
1 - 6  
1 - 6  
1 - 6  
1 - 6  
Electrical Components  
Part #  
22512601 Terminal Strip  
Description  
No. Fans  
1 - 6  
Defrost Termination/Fan Delay  
— Klixon type  
5709L  
1 - 6  
1 - 6  
Defrost Termination/Fan Delay  
— Adjustable type  
4267W  
2891040  
5708L  
Room Thermostat  
Heater Safety — Klixon type  
1 - 6  
1 - 6  
40880701 Access Panel - Refrig.  
40880901 Back Panel - Refrig.  
40881001 Back Panel - Elect.  
40881201 End Panel - Hot Gas Refrig.  
Drain Fittings  
Part #  
26925101 Drain Fitting Kit  
Description  
No. Fans  
1 - 6  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Standard Nozzle Selection  
Model RLC Air Defrost  
No. of  
No. of  
Circuits  
Distributor Tube (in.)  
Model  
R-404A  
R-22  
Fans  
OD  
Length  
15  
RLC040  
RLC052  
RLC065  
RLC070  
RLC090  
RLC104  
RLC120  
RLC130  
RLC140  
RLC156  
RLC180  
RLC208  
RLC260  
RLC312  
RLC370  
1
1
1
2
2
2
2
2
3
3
3
4
5
6
6
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
1
1
2
2
3
3
3
4
4
5
5
5
9
9
10  
-
-
-
-
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
L-1/2  
L-1/2  
L-3/4  
L-3/4  
L-1  
L-1  
L-1  
L-1-1/2  
L-1-1/2  
L-1-1/2  
L-2  
L-2-1/2  
L-3  
L-1/3  
L-1/3  
L-1/2  
L-1/2  
L-3/4  
L-3/4  
L-3/4  
L-1  
L-1  
L-1  
L-1-1/2  
L-2  
L-2  
Model ELC/EFC Electric Defrost  
Low Temp.  
-30°F to 0°F SST  
-34°C to -18°C SST  
Medium Temp.  
10°F to 25°F SST  
-12°C to -4°C SST  
No. of  
Fans  
No. of  
Distributor Tube (in.)  
Model  
Circuits  
OD  
Length  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
R-404A  
L-1/2  
L-1/2  
L-1/2  
L-3/4  
L-1  
R-22  
L-1/4  
L-1/4  
L-1/3  
L-1/2  
L-3/4  
L-3/4  
L-1  
R-404A  
R-22  
L-1/4  
L-1/4  
L-1/3  
L-1/2  
L-1/2  
L-1/2  
L-3/4  
L-1  
ELC035  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
3/16  
2
2
2
4
4
5
5
6
8
10  
9
9
10  
2
4
4
5
8
8
L-1/3  
L-1/3  
L-1/3  
L-1/2  
L-3/4  
L-3/4  
L-1  
L-1-1/2  
L-1-1/2  
L-1-1/2  
L-2  
ELC040  
ELC047  
ELC065  
ELC075  
ELC090  
ELC120  
ELC140  
ELC160  
ELC180  
ELC200  
ELC240  
ELC280  
EFC041  
EFC068  
EFC080  
EFC102  
EFC136  
EFC170  
EFC204  
EFC235  
L-1  
L-1-1/2  
L-1-1/2  
L-2  
L-1  
L-1  
L-1  
L-1  
L-2  
L-1-1/2  
L-1-1/2  
L-2  
L-2-1/2  
L-2-1/2  
L-3  
L-1-1/2  
L-1-1/2  
L-2  
L-1/4  
L-1/3  
L-1/2  
L-3/4  
L-3/4  
L-1  
L-2  
L-2  
L-2-1/2  
L-1/3  
L-1/2  
L-3/4  
L-3/4  
L-1  
L-1/2  
L-3/4  
L-1  
L-1/3  
L-1/2  
L-3/4  
L-3/4  
L-1  
L-1-1/2  
L-1-1/2  
L-2  
L-1  
L-1-1/2  
L-2  
L-2-1/2  
L-2-1/2  
L-1-1/2  
L-2  
8
10  
L-1-1/2  
L-1-1/2  
L-2  
Model GLC Hot Gas Defrost  
Low Temp.  
-30°F to 0°F SST  
-34°C to -18°C SST  
Medium Temp.  
10°F to 25°F SST  
-12°C to -4°C SST  
No. of  
Circuits  
Distributor Tube (in.)  
Model  
No. of Fans  
OD  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
1/4  
Length  
15  
R-404A  
J-1/2  
J-1/2  
J-3/4  
J-1  
R-22  
J-1/4  
J-1/3  
J-1/3  
J-1/2  
J-3/4  
G-3/4  
G-1  
R-404A  
R-22  
J-1/4  
J-1/4  
J-1/4  
J-1/3  
J-1/2  
G-1/2  
G-3/4  
G-1  
GLC035  
1
1
1
2
2
2
3
3
4
4
5
6
6
1
2
2
3
4
5
6
6
2
2
2
4
4
5
5
6
8
10  
9
9
10  
2
4
4
5
8
8
J-1/3  
J-1/3  
J-1/2  
J-3/4  
J-3/4  
G-3/4  
G-1  
GLC040  
GLC047  
GLC065  
GLC075  
GLC090  
GLC120  
GLC140  
GLC160  
GLC180  
GLC200  
GLC240  
GLC280  
GLC041  
GLC068  
GLC080  
GLC102  
GLC136  
GLC170  
GLC204  
GLC235  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
15  
J-1  
G-1-1/2  
G-1-1/2  
G-2  
G-1  
G-1-1/2  
G-1-1/2  
E-1-1/2  
E-2  
G-2  
G-1-1/2  
E-1-1/2  
E-2  
G-1  
E-1  
E-2-1/2  
E-2-1/2  
E-3  
E-1-1/2  
E-1-1/2  
E-2  
J-1/4  
J-1/2  
J-1/2  
G-3/4  
G-1  
E-2  
E-2  
E-4  
E-2-1/2  
J-1/3  
J-1/2  
J-3/4  
G-3/4  
G-1  
E-2-1/2  
J-1/3  
J-3/4  
J-3/4  
G-1  
G-1-1/2  
G-1-1/2  
G-2  
J-1/2  
J-1  
J-1  
G-1-1/2  
G-2  
15  
15  
15  
15  
G-2  
G-1-1/2  
G-2  
G-1  
G-1-1/2  
E-1-1/2  
8
10  
G-2-1/2  
E-3  
E-2  
E-2  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For more information on Chandler refrigeration products, contact  
A Brand of Heatcraft Refrigeration Products LLC  
2175 West Park Place Blvd. • Stone Mountain, GA • 30087  
800-321-1881 • FAX 770-465-5990  
Since product improvement is a continuing effort, we reserve the right to make  
changes in specifications without notice.  
CH-LOPTB-0508 | Version 000  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Air Conditioner 24R200 User Manual
Graco Crib 1762879 User Manual
Graco Inc Pressure Washer 308 518 User Manual
Hamilton Beach Coffeemaker 40514 User Manual
Hamilton Beach Juicer 66333 User Manual
Hamilton Beach Slow Cooker 840133300 User Manual
Hasbro Games 007 Golden Eye User Manual
Hawking Technology Network Card HWU54DM User Manual
HP Hewlett Packard Scanner 815MFP User Manual
Husky Pressure Washer 1750 PSL User Manual