Hearth and Home Technologies Switch WSK MLT User Manual

WSK-MLT MULTIFUNCTION WALL SWITCH  
- INSTALLATION AND OPERATING INSTRUCTIONS -  
Introduction  
CONTROL  
WIRE  
The WSK-MLT multifunctional wall switch is designed to  
control ame height, blower speed, and auxiliary functions  
on your gas fireplace. For models equipped with the  
Intellire system (IPI), the cold climate function can control  
the pilot ame as well. The wall switch is equipped with  
thermostat functions which can automatically control the  
temperature in the room in which it is installed. The wall  
switch interfaces with both intermittent and standing pilot  
systems. An auxiliary function provides 110-120 VAC  
source for added features the replace may have installed.  
Electrical ratings for the control box are 110 VAC, 60 Hz,  
and is required for operation of this device.  
WALL SWITCH  
FLAME  
SOLENOID  
COVER  
PLATE  
Installation precautions  
This remote is tested and safe when installed in accordance  
with this installation manual. It is your responsibility to  
read all instructions before starting installation and to  
follow these instructions carefully during installation. Do  
not install any components that may be damaged. Do not  
modify, disassemble, or substitute any of the components  
included with this kit. Installation of this unit must be done  
by a qualied service technician.  
CONTROL  
BOX  
Figure 1.  
1.0 Installation instructions  
1.1 Determine location  
Placement of this wall switch may affect performance  
or accuracy of the automatic (thermostat) control. An  
assessment of the space should be done prior to installation  
for optimal performance. See the installation instructions  
section I for recommendations.  
Determine the location for the wall switch. The chosen  
location should provide an accessible location in the  
same space as the gas replace. Never place this unit in  
a separate room. The control wire supplied with this switch  
is 33 ft (10M) in length. The distance from the replace to  
the switch may be lengthened provided that the wire used  
never exceeds 50 ft, and that the distance from the replace  
to the switch never exceeds 30 ft.  
NOTE: The electrical junction box provided with the replace  
must be wired with 110 VAC before installing this kit. See  
owners manual for details.  
The switch should be mounted into a listed electrical junc-  
tion box. The junction box should be dedicated to this wall  
switch. Never install this wall switch into a junction box  
that is shared with other electrical service or devices. If  
possible, install this unit on an interior wall of the residence  
at a recommended height of 5 ft from the ooring. Should  
the switch be installed on an exterior wall, be certain wall  
insulation is kept intact and not damaged or dislodged dur-  
ing the installation of the electrical junction box.  
All wiring should be done by a qualied electrician and  
shall be in compliance with local codes and with the  
National Electric Code ANSI/NFGA No. 70- current (in the  
United States), or with the current CSA C22.1 CANADIAN  
ELECTRIC CODE (in Canada).  
WARNING  
Shock Hazard  
For exterior wall installations, it is recommended that the  
junction box be sealed with caulking material. This will  
minimize heat loss through this location and improve the  
accuracy of the automatic (thermostat) operation.  
Do not provide any power to this unit until all  
wiring is completed. Failure to do so may destroy  
parts of this device and render it unusable, and  
may lead to possible electrical shock.  
Fire Hazard  
Modification of any parts or installation of  
damaged components will void the warranty,  
and you may possibly cause a re hazard.  
Copyright 2007  
Hearth & Home Technologies Inc.  
20802 Kensington Blvd., Lakeville, MN 55044  
130-911G 12/07  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3 Installing the control box  
For units WITHOUT factory installed rocker switch.  
CAUTION  
Standing Pilot Ignition:  
Find these parts packed with WSK-MLT:  
• Rocker switch  
• Do NOT install the control box when replace is hot.  
• Do NOT plug control box in until all connections are  
complete.  
• Rocker switch bracket  
• Strips of Velcro  
1. Place control box into the base pan area of the replace.  
Place unit as close to the louvers or decorative front as  
possible and to either the left or right side.  
• Black and white wire pigtails - (2)  
• Female ends (only used on Standing Pilot  
applications) - (2)  
2. Connect the red, yellow or white, and green wires to the  
appropriate labeled terminals on the control box.  
Cut male ends off black wires on each pigtail. Strip each  
end of wire approximately 1/4 inch. Slide each stripped  
wire into a female end and crimp. Slide rocker switch into  
bracket until it snaps into place. Attach end of each pigtail  
to each side of rocker switch. Find the top (brown) and  
bottom (red) wires from the control box and attach to white  
wires from rocker switch.Attach one black wire to the TH/TP  
side of gas valve and the other to the TH side of the gas  
valve. Attach the Velcro to the bottom of the rocker switch  
bracket and mount in a convenient location next to gas  
valve. (Refer to Figure 4).  
For units WITH factory installed rocker switch.  
3. Find the red and brown pigtail wire (labeled “ FOR USE  
WITH REMOTE OR WALL SWITCH ONLY”) which are  
attached to the replace ON/OFF rocker switch.  
Standing Pilot Ignition: Connect these wires with the  
red and brown wires extending from control box (Fig 2).  
Intellire (IPI): Connect these wires with the brown  
wires extending from the control box (see Figure 3).  
For units WITHOUT factory installed Rocker Switch  
YELLOW  
BLACK  
VALVE  
WHITE  
RED  
REAR VIEW  
GREEN  
To  
RED  
NOT  
Thermopile  
USED  
BLACK  
G W* R  
BROWN  
BROWN  
RED  
NOT  
USED  
BLACK  
WHITE  
WHITE  
RED  
RED  
FRONT VIEW  
FLAME  
BLACK  
SOLENOID  
ORANGE  
ORANGE  
SWITCH AND WIRE  
ASSEMBLY SUPPLIED  
WITH WSK-MLT  
FLAME HIGH/LOW  
FACTORY  
CONNECTED  
TOGETHER  
BLACK  
YELLOW  
YELLOW  
AC PLUG  
FAN THERMOSTAT  
BLACK  
AUX  
CONNECTION  
* May be labeled as “W” or “Y”.  
FAN  
CONNECTION  
GROUND PIGTAIL  
GREEN  
BLACK  
Figure 4. Standing Pilot Wiring Diagram  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
For units WITHOUT factory installed Rocker Switch  
BLACK  
BATTERIES  
SWITCH AND WIRE  
ASSEMBLY  
SUPPLIED  
WITH WSK-MLT  
WHITE  
BROWN  
YELLOW  
or  
BLACK RED  
GREEN  
ORANGE  
WHITE  
RED  
REAR VIEW  
GROUND  
BLACK  
GREEN  
IPI  
VALVE  
1
2
G
W*  
R
IPI  
MODULE  
3
4
5
6
7
8
BROWN  
BROWN  
RED  
3V DC  
FLAME  
BLACK  
SOLENOID  
FRONT VIEW  
RED  
RED  
FLAME ON  
ORANGE  
ORANGE  
FLAME HIGH/LOW  
YELLOW  
YELLOW  
FACTORY  
CONNECTED  
TOGETHER  
AC  
PLUG  
ADAPTER WIRES  
BLACK  
FAN THERMOSTAT  
BLACK  
AUX  
CONNECTION  
GROUND  
FAN  
CONNECTION  
PIGTAIL  
GREEN  
* May be labeled as “W” or “Y”.  
BLACK  
Figure 5. Intellire (IPI) Wiring Diagram  
Intellire (IPI):  
4. If equipped with a fan, plug the fan cord into the power  
cord labeled “FAN”. Disconnect the two wires from the  
fan thermostat switch on the replace. Disconnect the  
two yellow wires from each other and connect them to  
the fan thermostat switch. Use one of the existing wires  
on the thermostat to connect to the proper end on the  
male terminated yellow wire.  
Find these parts packed with WSK-MLT:  
• Rocker switch  
• Rocker switch bracket  
• Strips of Velcro  
• Black and white wire pigtails - (2)  
• Female ends (not used on IPI applications) - (2)  
Slide rocker switch into bracket until it snaps into place.  
Attach one pigtail to one side of rocker switch and the other  
pigtail to the other side of the rocker switch. Find the two  
brown wires from IPI module and attach them to the two  
black wires from the rocker switch. Find the two brown  
wires from the control box and attach them to the white  
wires from the rocker switch. Attach the Velcro to rocker  
switch bracket and place rocker switch next to control box.  
(Refer to Figure 5).  
Note: The fan rheostat has now been removed from the  
circuit and is inoperable. Use the wall switch to change fan  
speeds. The fan temperature sensor is still operable and  
will turn the fan on and off when the replace heats up and  
cools down.  
5. Remove the screw and knob from the variable regulator  
and discard.  
6. Unscrew the nut from the regulator and discard.  
Proceed to Step 4.  
7. Remove the bag containing a washer and blue and red  
plungers from the side of the ame control solenoid.  
8. Place washer on ame control solenoid (see Figure 6).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
GAS CONTROL  
VALVE  
KNOB  
SCREW  
NUT  
VARIABLE REGULATOR  
WASHER  
WASHER  
VARIABLE  
REGULATOR  
SOLENOID  
VARIABLE  
REGULATOR  
JAM NUT  
FLAME CONTROL  
SOLENOID  
PLUNGER  
Figure 6.  
9. Insert the correct plunger (blue - natural gas, red - pro-  
Intellire (ipi) models only  
pane) into the ame control solenoid (see Figure 6).  
For units with factory installed rocker switch see Fig. 3.  
10. Thread the ame control solenoid with correct plunger  
into the thread hole in the variable regulator. Turn into  
valve approximately two full turns. Do not tighten or  
damage may occur.  
For units without factory installed rocker switch see  
Fig. 5.  
14. Disconnect main valve wire (green) from the front of  
the valve. Connect red control wire to red adapter wire  
containing one large male end and one small female  
end and connect to valve terminal (see Figure 3).  
Connect the other red control wire to red adapter wire  
containing one large female end and one small male  
end and connect the green module wire (previously  
disconnected from valve front).  
11. Set the valve manifold pressure to the proper setpoint.  
The setpoint is adjusted by rotating the solenoid to  
adjust its depth into the valve. Using a manometer  
to monitor pressure, rotate the solenoid so that the  
output is set to proper range.  
12. Tighten the jam nut on the threaded shaft of the  
solenoid against the valve regulator. Use an open-  
ended ½” wrench to tighten the nut, while holding  
the solenoid in the proper position. This step will en-  
sure that the solenoid remains locked into the proper  
position.  
15. Carefully unplug battery pack wires from IPI module.  
Plug battery pack into red and black battery wires  
(labeled “Battery”).  
16. Plug red and black wires from control box (labeled  
“3V DC”) to the red and black wires extending from IPI  
module (labeled “3V DC”). Red connects to red, black  
connects to black.  
13. Connect orange wires from control box to the ame  
control solenoid.  
14. Ground the control box by attaching the green ground  
wire (has round ring-terminal on end) to the replace  
base pan or appropriate ground.  
NOTE: Transformer supplied with the IPI system is NOT  
used. Disconnect the transformer from the electrical junction  
box. Transformer may be removed from the replace, but we  
recommend leaving it connected to the IPI module.  
CAUTION  
Lay the control box and wires at on the base pan to avoid  
potential overheating problems.  
13. Connect auxiliary functions. This unit is equipped with  
a 110 VAC supply cord (labeled “AUX”) for controlling  
auxiliary functions such as an electric ember bed.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
• Once pressure is achieved spin jam-nut on solenoid stem  
tight against regulator face to prevent rotation. Do not  
overtighten.  
2.0 Operating Instructions  
For units WITH factory installed rocker switch.  
The ON/OFF rocker switch on the replace (located near  
the gas valve) must be in the “OFF” position for use with  
the WSK-MLT system. The ON/OFF rocker switch will NOT  
function with this device on Intellire (IPI) models except  
during a power outage.  
• Press ame button twice to turn replace off.  
• Remove manometer tube and tighten or close pressure  
tap. Use a soap solution to carefully check the pressure  
tap for leaks.  
For units WITHOUT factory installed rocker switch.  
The ON/OFF rocker switch now installed on the replace  
must be in the OFF position for use with the IPI or stand-  
ing pilot system. The ON/OFF rocker switch will only be  
used to control the replace in a no-power condition. For  
standing pilot systems use the rocker switch to turn the  
replace on and off. When power is restored switch the  
rocker switch to OFF. For IPI system refer to “Operation  
Under Battery Power” for instructions.  
2.2 Wall Switch Button Operation  
(Refer to Figure 7)  
Flame Button  
• Button Press: Unit On / Flames High, Turns on auxiliary  
power  
• Button Press: Flames Low  
• Button Press: Unit Off / Flames Off, Turns off auxiliary  
power  
After all connections are made and the control box is  
grounded, plug power cord into the replace junction box.  
The wall switch will be functional at this time.  
Fan / Blower Button  
• Button Press: Fan High (“3”)  
• Button Press: Fan Medium (“2”)  
• Button Press: Fan Low (“1”)  
• Button Press: Fan Off  
NOTE: The temperature displayed by the wall switch may  
take up to 30 minutes to stabilize on initial power-up.  
NOTE: Check control box and assure switch is in the “OFF”  
position. This switch is only used on Intellire (IPI) control  
systems under battery operation.  
Temperature Button  
• Button Press will toggle between Automatic and Manual  
Operation  
• Press and Hold the button for 3 seconds to toggle between  
Fahrenheit and Centigrade Temperature Display.  
Automatic Operation: Controller will monitor temperature  
and control unit according to the set point.  
Manual Operation: Controller will not automatically change  
settings.  
SET Set Temperature Button  
• Button Press: Displays Set Point  
• Use Up and Down Arrows to Adjust Set Point  
• Press Set Button to Store New Set Point  
Temperature Set Point can be adjusted between the ranges of:  
45-900 Fahrenheit or 7-320 Centigrade  
Figure 7.  
NOTE: The controller will turn off the replace at 20 F over  
set point and turn it back on at 20 F below set point.  
2.1 Setting Flame Height/manifold pressure  
(To be done by a qualied service technician). Upon initial  
power-up of this device, valve pressure must be set for  
ame adjustment.  
Up and Down Arrows  
• Push to adjust set point temperature under automatic  
control.  
• Loosen output pressure tap on valve and connect with  
pressure manometer.  
AUX Auxiliary Button  
• Press ame button once (Fig. 7); replace will light with  
ames on high.  
• Button Press: Turns on auxiliary power  
• Button Press: Turns off auxiliary power  
Can be operated independently of all functions.  
• Turn solenoid clockwise to increase pressure, counter-  
clockwise to decrease pressure until manifold pressure  
on high is 3.5” water column for natural gas (NG), 10.0”  
water column for propane (LP).  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Child Proof Mode  
To Enter Child Proof Mode:  
• Press the UpArrow Button twice and DownArrow Button  
once. The unit will send out 3 beeps and an indicator in  
the LCD panel will show that the child proof is on.  
BATTERY  
OPERATION  
SWITCH  
To Leave Child Proof Mode:  
CONTROL  
BOX  
• Press the UpArrow Button twice and DownArrow Button  
once. The unit will send out 3 beeps and the indicator in  
the LCD panel that shows that the child proof is on will  
disappear.  
“OFF”  
POSITION  
“BATTERY ON”  
POSITION  
NOTE: When in Child Proof Mode, only the arrow buttons  
will have functionality. Unit can enter Child Proof when the  
replace is on or off.  
Figure 8  
SERVICE PARTS LIST  
INTELLIFIRE (IPI) MODELS ONLY  
Cold Climate Button  
DESCRIPTION  
SOLENOID  
SERVICE PART NO.  
HTI-17-006  
• Button Press: Turns on Climate Control  
• Button Press: Turns off Climate Control  
WALL SWITCH/KEY PAD  
CONTROL WIRE  
COVER PLATE  
HTI-12-007  
HTII-23-007  
HTI-21-007  
This allows the pilot ame to stay lit when activated, a ben-  
et of this is reduced condensation on the glass at start-up  
in colder climate conditions.  
CONTROL BOX  
ACTUATOR PINS  
SWITCH KIT  
HTI-13-007  
HTI-17-116  
HTI-25-007  
Operation Under Battery Power  
A switch on the control box allows for battery power under  
no-power conditions (see Figure 8). By controlling the  
power supply with this switch, the batteries are supplying  
power only when needed, thus extending battery life. The  
switch also provides a convenient means for switching to  
battery power should there be a loss of 110 VAC power to  
the control box.  
• In the event of a power failure, switch the battery  
operation switch to the “Battery ON” position.  
• The replace can now be turned on and off with the ON/  
OFF rocker switch located near the gas valve.  
• The wall switch functions will not operate under battery  
power.  
• Under battery control the only available function is ame  
“On” and “Off” in the high position.  
To maximize battery life, and to restore full function  
capability of the wall switch, ip switch to “OFF” position  
after 120 VAC power is restored.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Inc Pressure Washer 1204E User Manual
Grizzly Kitchen Utensil T25225 User Manual
Hans Grohe Indoor Furnishings 34115XX1 User Manual
Havis Shields Telescope C PED Series User Manual
Heat Glo LifeStyle Indoor Fireplace 6100PLUS User Manual
Heath Zenith Home Safety Product SH 5318 User Manual
Honeywell Home Security System 800 06894 User Manual
HP Hewlett Packard Camcorder PW550 User Manual
Huey Chiao Bluetooth Headset HCB29 User Manual
Husqvarna Trimmer 333RJ User Manual