Hasselblad Scanner Flextight 848 User Manual

User's Guide  
Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
3
Table of Contents  
Hardware Reference - Flextight 848  
Warnings and Restrictions  
System Requirements  
5
6
7
Front Panel  
9
Back Panel & Connectors  
Cut-Away View  
10  
11  
Setting up the Scanner  
12  
12  
12  
13  
Environmental Requirements  
Electrical Requirements  
Installation Procedure, FireWire Interface  
Operating Instructions  
15  
Resolutions  
19  
19  
True Resolutions  
Calibrating the Scanner  
Focus Calibration  
White Calibration for Reflectives  
20  
21  
22  
The Light Tubes  
General  
Replacing the Light Tubes  
25  
25  
25  
Cleaning the External Surface of the Scanner  
Disposal  
27  
27  
28  
29  
30  
Technical Specifications  
FCC Notice  
CE - Declaration of conformity  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
5
Hardware Reference - Flextight  
848  
This manual provides important information about using your Flextight  
848 scanner.  
Topics include:  
Important warnings and restrictions  
System requirements  
Diagrams of the front panel, rear panel, and internal structure of the  
Flextight 848 scanner  
Installation instructions  
Environmental requirements  
Electrical requirements  
Operating instructions  
Special considerations for scanning 35mm originals  
Calibration instructions  
Maintenance advice  
Disposal instructions  
Technical specifications  
Declarations of FCC and CE regulation conformity  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
6
Warnings and Restrictions  
Warnings and Restrictions  
Read all of the included documentation before attempting to install  
and use the scanner.  
Do not touch the originals and/or the original holder while scanning.  
Do not start scanning or previewing until an original holder with an  
original has been mounted.  
The original holder is only to be mounted or removed when the drum  
is in the load position.  
When you turn on the scanner, the drum will roll to the load position,  
if it is not there already. Do not touch the scanner while the drum is  
rotating.  
Do not place your fingers or any other object into the scanner while it  
is connected to power.  
Before servicing or opening the scanner, the power supply must be  
disconnected from the mains (unplugged). It is not sufficient simply to  
press the on/off button.  
Install the scanner in a location where children can not get to it. It  
contains small openings and moving parts that can cause injury.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
7
System Requirements  
System Requirements  
Below are the basic hardware requirements for the PC or Macintosh  
system to which the scanner is to be connected.  
For information about the processor, operating system, RAM and  
harddisk requirements please refer to the “Software Reference” manual,  
that comes with the FlexColor software.  
Screen resolution of 800 x 600 pixels with true colors (24-bits).  
Mouse or other pointing device.  
FireWire interface.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
8
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
9
Front Panel  
Front Panel  
A
D
E
F
B
C
G
H
Figure 1: Front panel features of Flextight 848  
A
Feed Table: must be in lower position for normal scanning. When  
scanner is not in use you can turn it to upright position flushing with  
the scanner front to protect it from dust etc. Adjust to horizontal  
position when using the 35 mm slide mount holder (see page 15).  
Light Table: for viewing originals. The grid helps you to align your  
transparent originals.  
B
C
D
Transparency Holder Guide: all transparency holders fit between  
two rails to keep them straight.  
Original Holder Clasp: all original holders slide into a slot here and  
are held in place by a magnetic clasp.  
E
F
Power Switch: press here to turn the unit on/off.  
Power Indicator (Green): Remains lit when ready to scan. Flashes  
when first installed to indicate that firmware must be loaded (it will  
be loaded automatically when you run FlexColor).  
Motor Drive Indicator (Yellow): lights when the scanner is  
repositioning the optics to scan in a new format or when drum is  
repositioning.  
Scan Indicator (Red): lights when scanning. Do not touch the  
scanner while this indicator is lit. If the light is flashing when not  
scanning, then an error has occurred - please contact your Flextight  
dealer for assistance.  
G
H
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
10  
Back Panel & Connectors  
Back Panel & Connectors  
A
B
Figure 2: Back panel features of Flextight 848  
A
B
Power Cable Socket: plug the power cable into this socket.  
FireWire Interface Sockets: plug a FireWire cable (max. 6 m) here  
and connect it to your computer. You can use the second plug to  
connect another device (hard disk, printer etc.) to the FireWire chain.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
11  
Cut-Away View  
Cut-Away View  
A
B
C
FLEXTIGHT  
O
RIGINAL  
HOLDER  
D
P
A
TENT  
PENDING  
E
F
G
Figure 3: Cut-away view of Flextight 848  
A
B
CCD Housing: this movable platform contains the light sensor and  
holds the optics.  
Positioning Lead Screws: for positioning of the CCD housing and  
optics housing for the appropriate resolution and original size.  
Optics Housing: focuses the image of the original on the CCD.  
Upper Light Source: illuminates reflective originals.  
Lower Light Source: illuminates transparent originals.  
Drum: rotates the original into the scanner and steps it past the CCD  
line of focus.  
C
D
E
F
G
Original Holder: a transparency holder is shown mounted and with  
the top layer held open.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
12  
Setting up the Scanner  
Setting up the Scanner  
Environmental Requirements  
Set up the scanner in a location that fulfils the following requirements:  
Keep the scanner away from sources of heat, such as direct sunlight or  
a radiator. Warm temperatures will degrade the quality of your scans -  
for best results, work in a cool environment.  
The scanner must be operated away from sources of strong  
electromagnetic interference. Although the scanner complies with all  
regulations governing electromagnetic immunity and Hasselblad has  
taken every reasonable step to make the unit immune to  
electromagnetic interference, it is still a precision electronic device so  
strong radio waves can interfere with your scans.  
The surface on which the scanner is placed must be stable and free  
from vibrations. If the scanner is shaken or moved while scanning,  
your results may be affected.  
If the scanner has been in a colder environment (e.g. outside or in  
storage) just before you set it up in a warmer room, then wait about  
two hours before using it - otherwise, condensation may form, which  
will prevent the scanner from operating correctly.  
Avoid using the scanner in areas where there is a high level of dust.  
Electrical Requirements  
The Flextight 848 power supply requires a mains voltage of between 100  
and 240 V AC at a frequency of 50 to 60 Hz. This is within the normal  
wall-socket power standards of most countries. Do not attempt to use  
Flextight 848 with any power source outside the specified range.  
The scanner and all devices attached to the scanner (computer, monitor,  
FireWire devices, etc.) must be grounded (i.e. use a three-point electrical  
connection).  
Note that the power supply may emit a low hissing sound when  
plugged in but not connected to the scanner. This is normal and will not  
damage the power supply or scanner.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
13  
Setting up the Scanner  
Installation Procedure, FireWire Interface  
1. Place the scanner on a table near your computer with the front  
facing away from you. Make sure that the location you choose meets  
all environmental - and electrical requirements as described on page  
11.  
2. When using a FireWire interface connection, it is not necessary to  
switch of your computer and other connected units. Connect a  
FireWire cable from one of the FireWire connectors on your scanner  
(see Back Panel & Connectors on page 10) to either the computer's  
FireWire connector or to a free FireWire connector on any other  
FireWire device already connected to your computer.  
3. Connect the round connector from your power supply to the round  
power supply socket on the back of the scanner.  
4. IMPORTANT: Make sure that the wall socket you are planning to  
use meets the electrical requirements outlined earlier.  
Plug the Flextight 848 power supply into a wall socket. Note that the  
power supply may emit a low buzzing sound when plugged in. This  
is normal and will not damage the power supply or scanner.  
5. Turn the scanner around so that the front is facing you.  
6. Your system is assembled. Turn on your computer and install the  
FlexColor image scanning software.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
14  
Operating Instructions  
CLOSED  
HORIZONTAL  
NORMAL  
D
E
A
F
G
H
J
FLEXTIGHT  
O
RIGINAL  
HOLDER  
à
PENDING  
P
A
TENT  
à
L
K
B
C
Figure 4: Operating the Flextight 848 scanner  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
15  
Operating Instructions  
Operating Instructions  
(See Figure 4 opposite).  
1. It is assumed that the scanner and FlexColor software have been  
properly installed.  
2. If not already done, turn the feed table (A) to normal position.  
3. Press the red power button (F) on the front of the scanner to switch it  
on. The green light (G) starts flashing. This means that no firmware  
has been downloaded yet. It will be downloaded automatically later  
when you first run the FlexColor program.  
4. Turn on your computer and start the FlexColor program. The green  
light (G) will stop flashing indicating that firmware has been  
downloaded to the scanner.  
5. Select the original holder (K) that matches your original:  
• For transparencies, choose one of the holders that has a square  
hole in it. The original must completely fill the hole with no edges  
showing. Also, no edges of the original must extend past the outer  
edges of the holder.  
The feed table (A) must be in normal position.  
• For reflectives, select the large A4/letter-size holder with the clear  
plastic layer.  
The feed table (A) must be in normal position.  
• For 35 mm slide frames use the optional 35 mm slide mount  
holder.  
The feed table (A) must be adjusted to horizontal position. This is  
obtained by lifting the table slightly upwards while pushing it  
gently into the scanner.  
Please note that when scanning 35 mm slide frames in the 35 mm  
slide mount holder it is recommended to use autofocus. See the  
FlexColor Software Reference for details.  
continues...  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
16  
Operating Instructions  
CLOSED  
HORIZONTAL  
NORMAL  
D
E
A
F
G
H
J
FLEXTIGHT  
O
RIGINAL  
HOLDER  
à
PENDING  
P
A
TENT  
à
L
K
B
C
Figure 4: Operating the Flextight 848 scanner  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
17  
Operating Instructions  
...continued  
NOTE! Each original holder has it's own unique identification code  
(a combination of small rectangular holes at the holder's leading  
edge). These codes, combined with the scanner's ability to detect the  
feed table position, ensure that the scanner will not operate unless  
the feed table position matches the selected original holder.  
6. Place the original holder (K) with the slotted tab facing into the  
scanner. For transparencies, the flexible magnetic layer must face  
upwards. For reflectives, the clear plastic sheet must face upwards.  
Make sure that the original holder fits between the appropriate  
guides (C) or (D) on both sides of the light table.  
7. Slide the holder gently into the slot (E) at the top of the feed table. It  
will slip about ½ cm (1/4 inch) into it. Do not press too hard. It slips  
in very easily and is held in place by a magnetic clasp. To remove  
the holder, simply pull it gently backwards.  
8. Lift the top layer of the original holder and place your original (L) as  
follows:  
• For transparencies, place your original with the emulsion side  
down. The original must completely fill the hole with no edges  
showing and with a minimum overlap of 2mm along each edge.  
Also, no edges of the original must extend past the outer edges of  
the holder. Use the grid on the light table (B) to help line up the  
image.  
• For reflectives, make sure that no part of the original extends past  
the edge of the holder. Use the dotted lines printed on the holder  
to line up the image. Handle the clear plastic layer only by the  
edges to avoid fingerprints. Curl the plastic layer back and slip  
the front edge into Flextight's foil holder.  
continues...  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
18  
Operating Instructions  
...continued  
9. Lay the top layer of the holder down flat over the original.  
• For transparency holders, the top layer is magnetic, which will  
hold the original fast.  
• For the reflective holder, note the four metal pegs (the top two are  
shown as A and C in Figure 5 below); make sure that the clear  
plastic sheet is pressed all the way down over all four pegs. Note  
also the two curved tabs at the top of the holder (B in the figure  
below); the clear sheet must slip under each of these tabs, as  
shown.  
A
B
C
Figure 5: Reflective holder, top  
10. Go to your computer and follow the directions given in the  
FlexColor software manual to take a preview, make settings, and  
take the final scan.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
19  
Resolutions  
Resolutions  
True Resolutions  
The table below shows the max. resolutions (in ppi) available with each  
of the original holders when scanning in True Resolutions mode.  
Max. resolution (ppi)  
Original  
at full scanning width.  
35 mm Portrait  
35 mm Landscape  
45 x 60 mm Portrait  
60 x 60 - 60 x 70 mm  
4" x 5" Portrait  
8000  
5000  
4000  
3200  
2040  
1600  
960  
13 x 18 Portrait  
A4 Portrait  
Table 1: True Resolutions  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
20  
Calibrating the Scanner  
Calibrating the Scanner  
The scanner requires two types of calibration:  
Focus calibration adjusts the positioning of the scanners optics for  
each zoom level. If your scans are coming out unfocused or at slightly  
the wrong size, then you may need to make a new focus calibration to  
adjust the zoom mechanism. The focus calibration is stored in the  
scanners flash PROM, so it is preserved when you move the scanner to  
a new computer. See "Focus Calibration" on page 21 for more  
information.  
White calibration is only required for reflective scans (it is done  
automatically for transparencies). During calibration, the scanner  
scans a white target to establish the white point along the full length  
of the scanners CCD. The results of the white calibration scan are  
saved on your computers hard disk, so you must make a new white  
calibration if you move the scanner to a new computer. See "White  
Calibration for Reflectives" on page 22 for more information.  
Both of the calibration procedures are simple and are initiated from the  
FlexColor program.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
21  
Calibrating the Scanner  
Focus Calibration  
The Flextight 848 scanner uses an adjustable zoom and focus mechanism  
to optimize its scanning resolution for each of the original formats it can  
handle. If you suspect your scans are not as sharp as they should be, then  
you may need to calibrate your scanner. Note that you must not calibrate  
the scanner every day. It is intended that the scanner is calibrated not  
more than once every three months. In most cases, this procedure will  
never be necessary.  
Use procedure below to make Focus Calibration:  
1. Locate the "Focus sheet" that came with your scanner. It is a 8 x 9 cm  
(3" x 3.5") square of transparent film with a black image on it.  
Focus sheet  
PN:40900026, rev. 1.10  
2. Load the sheet into the 6 x 6 original holder with the lines pointing  
towards the scanner (vertically). Place the sheet as straight as  
possible. Use the scanners light table grid and the corners marked on  
the sheet to help align it.  
3. Select Focus Calibration from the Maintenance menu.  
4. Click on the Calibrate button, and the focus calibration starts.  
5. When the focus calibration is finalized, the focus calibration window  
closes again.  
Your scanner is now calibrated for all resolutions and for both  
transparent and reflective originals.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
22  
Calibrating the Scanner  
White Calibration for Reflectives  
The Flextight scanner uses a white reference to make sure that all  
elements in the scanner's CCD react consistently to light brightnesses.  
The scanner has been calibrated from the factory, and the calibration  
data is stored in the scanner’s flash PROM.  
As the scanner ages, the properties of the light tubes may change  
slightly. Therefore, you must redo the white calibration every six months  
or so and immediately after changing the light tubes.  
Use procedure below to make White Calibration:  
1. Find the white calibration sheet that came with your scanner. It is a  
square white piece of paper (219 x 219 mm (8.6" x 8.6")).  
If you have lost the white calibration sheet, then you can use a flat  
(non-textured), perfectly white piece of paper of the same  
dimensions.  
2. Your scanner came with several clear plastic layers for the reflective  
original holder. If you have used the reflective holder before, make  
sure that there are no finger prints or other marks on the plastic  
layer. Replace the layer with a new one if necessary.  
3. Align the top edge of the sheet with the dotted line near the top of  
the original holder (see Figure 6 opposite). Align each side of the  
target with the edges of the original holder.  
4. Select White Calibration from the Maintenance window. The  
External White Calibration window appears.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
23  
Calibrating the Scanner  
Align the top edge of  
the calibration sheet  
with the dotted line  
near the top of the  
original holder  
Align the side edges of  
the calibration sheet  
with the side edges of  
the original holder  
Figure 6: Positioning the white calibration sheet on the reflective holder  
5. Click on Calibrate. The scanner will take several scans of the white  
target. The process will take about eight minutes.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
24  
The Light Tubes  
C
B
A
1
D
2
G
F
E
PULL OUT  
PRESS  
à
PRESS  
PULL OUT  
Figure 7: Replacing the Light Tubes  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
25  
The Light Tubes  
The Light Tubes  
General  
The Flextight 848 contains two light tubes: one for illuminating reflective  
originals from above, the other for shining light through transparencies  
from below.  
Replacing the Light Tubes  
If your scans are suddenly coming out black (or all white if you are  
scanning negatives), then one of your light tubes may be defective.  
Make a preview using both types of scans (transparent and reflective) to  
find out which tube is affected.  
If transparencies are not working, then the bottom tube may be  
burned out.  
If reflectives are not working, then the top tube may be burned out.  
Follow procedure below to replace a tube:  
(See Figure 7 opposite).  
1. Get the appropriate replacement lamp (ask your Flextight dealer).  
2. Turn off and unplug the scanner from the primary power supply.  
3. IMPORTANT: Let the light tubes cool down for app. 10 minutes  
before proceeding.  
3. Remove the front panel (A) by pulling it outwards at the bottom and  
lift it off.  
4. Remove the two black allen screws (B) (one in each side) using a 3  
mm allen key. Do not remove any other screws.  
5. Remove the two side panels (C) and (D) by lifting them slightly  
upwards and then outwards.  
NOTE! It may require a firm push upwards to release the panels.  
6. Turn the feed table (E) to upright position.  
7. Locate the tube to be replaced and dismount the plug (F).  
continues...  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
26  
The Light Tubes  
C
B
A
1
D
2
G
F
E
PULL OUT  
PRESS  
à
PRESS  
PULL OUT  
Figure 7: Replacing the Light Tubes  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
27  
Cleaning the External Surface of the Scanner  
...continued  
8. Remove the defective tube:  
• Press the flaps backwards to release the tube.  
• Pull the tube gently out of the holders and then sideways out of  
the scanner.  
9. Insert the replacement tube and mount it into the holders making  
sure that it is properly held in place by the flaps.  
10. Connect the plug (F).  
11. IMPORTANT: The "T" on the lamp board cover (G) indicates the  
socket for the transparencies tube.  
12. Lower the feed table (E).  
13. Mount the side panels (C) and (D), the screws (B) and the front  
panel (A) following the reverse of the procedure used when  
removing them.  
NOTE! When mounting the front panel (A) make sure to give it a  
firm push at the bottom to click it properly into position.  
14. Turn on the scanner and check function of the new tube.  
Cleaning the External Surface of the Scanner  
If the external surface of the scanner becomes dirty, then clean it with a  
damp cloth. Be careful not to get any moisture inside the scanner or on  
any of the connectors. Do not use alcohol or other solvents.  
Disposal  
If you need to dispose of the scanner, it must be delivered to an  
authorized waste plant for electronics equipment.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
28  
Technical Specifications  
Technical Specifications  
Power Connector:  
24 VDC  
60W  
Power Consumption  
Max. 60 W during operation  
Power Requirements  
100-240V AC, 1.3A, 50-60Hz  
Interface to Computer  
FireWire (IEEE 1394)  
Front Panel  
One multifunction switch (on/off switch)  
Status indicator LED’s  
Drum Force  
1kg (2.2lbs)  
Operating Environment  
Operating Temperature: 10 - 35°C (50 - 95°F)  
Recommended Working Temperature: 10 - 25°C (50 - 77°F)  
Humidity: 20 - 80% RH (no condensation)  
Storage Environment  
Temperature: 0 - 50°C (32 - 122°F)  
Relative humidity: 20 - 80% RH (no condensation)  
Originals  
Transparencies: from 35mm to 4x5 inches, <1mm thick  
Reflectives: up to 220 x 310mm (A4 oversize), <1mm thick  
Standard 35 mm dias in frames (optional)  
Lamp type  
Color optimized fluorescent lamp  
Dimensions  
Height: 645 mm (25.4")  
Width:  
Depth:  
385 mm (15.2")  
220 mm (8.7")  
(feed table closed)  
440 mm (17.3") (feed table open)  
Weight  
17 kg (38 lbs)  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
29  
FCC Notice  
FCC Notice  
This equipment has been tested and found to comply with the limits for  
a Class A digital device, pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 848  
30  
CE - Declaration of conformity  
CE - Declaration of conformity  
HASSELBLAD A/S  
HEJREVEJ 30  
DK - 2400 COPENHAGEN NV  
TELEPHONE +45 7026 0800  
TELEFAX +45 7026 0900  
REG./VAT NO. 18635445  
Declaration of conformity  
Application of Council Directives: ................. 89/336/EEC amended by 92/31/EEC,  
93/68/EEC. 91/157/EEC.  
C73/23/EEC amended by 93/68/EEC.  
Standards to which Conformity is declared: EN61000-6-1 2001, EN61000-6-3 2001  
and EN60950:2000.  
Manufacturer: ........................................... Hasselblad A/S  
Hejrevej 30  
DK-2400 Copenhagen NV/  
Denmark  
Type of Equipment: .................................... Desktop CCD scanner  
Model name: ............................................ Flextight 848  
The undersigned, hereby declare that the equipment specified above conforms to the  
above Directives and Standards.  
Place ....................................................... Copenhagen NV  
Date ........................................................ September 12th, 2004  
Full name ................................................. Christian Poulsen  
Position .................................................... CEO  
Signature  
User's Guide - Flextight 848  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Charcoal Grill H6256 User Manual
Harbor Freight Tools Air Compressor 93785 User Manual
Hasbro Games 13744 User Manual
Heath Zenith Work Light UT 5512 BZ User Manual
Hotpoint Washer Dryer WDD740 User Manual
HP Hewlett Packard Work Light B User Manual
Huawei Cell Phone HUAWEI Ascend Q User Manual
Husqvarna Lawn Mower Z4218 User Manual
IBM Bicycle Accessories S84H 4552 00 User Manual
Ice O Matic Ice Maker EF 450 Series User Manual