SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09CK3W3N
HSU-09CK6G2N
HSU-09CK6B2N
HSU-12CK3W3N
HSU-12CKCS3N
HSU-12CK6G2N
HSU-12CK6B2N
HSU-12CKAG3N
HSU-12CKAB3N
HSU-18CK3W3N
HSU-18CK6B2N
HSU-18CK6G2N
HSU-18CKBS3N
HSU-15CKBS5N
HSU-18CKBS5N
HSU-18CKAB3N
HSU-18CKAG3N
HSU-15CKAG5N
HSU-18CKCS3N
HSU-24CK6B2N
HSU-13CXAS5N
HSU-13CXAS3N
HSU-13CXAR3N
HSU-13CXBW3N
HSU-19CXBW5N
HSU-24CXAS3N
HSU-19CXAS5N
HSU-19CXAS3N
HSU-09LEK03-Y3
HSU-12LEK03-Y3
HSU-18LEK03-Y3
HSU-24LEK03-Y2
HSU-09LEK03/R2(DB)
HSU-24LEK03/R2(DB)
HSU-10LIN13
HSU-09LTS14
HSU-12LTS14
HSU-18LTS14
HSU-24LTS14
HSU-07LEK03
HSU-10LQA13
HSU-15LQA13
AS12GS1ERA
AS18GS1ERA
HSU-10LQAB13
HSU-15LQAB13
AS12GB2LAA
HSU-10VEK03
HSU-13VEK03
HSU-18VEK03
HSU-24VEK03
AS05GA1LAA
AS09GA1LAA
AS12GB1LAA
AS18GD1LAA
HSU-19CXAR3N
HSU-19CXBW3N
Contents
HSU-09LQA03/R2(DB)
HSU-12LQA03/R2(DB)
HSU-09LQA13/R2(DB)-WT
HSU-09LQA13/R2(DB)-BK
HSU-12LQA13/R2(DB)-WT
HSU-12LQA13/R2(DB)-BK
HSU-12LEK03/R2(DB)
HSU-18LEK03/R2(DB)
HSM24HEK03/R2(DB)
2
3
6
7
8
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
CAUTIONS
TROUBLE SHOOTING
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
0010564364
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Base Operation
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
TURBO
/QUIET
Remote controller
1
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
2
3
SWING
4
the following modes:
Pi
2
3
SLEEP
HEALTH
Room
Timer
Designated
Fan Operation
mode
TIME
ON
TIME
OFF
temperature temperature mode speed
Above 23oC 26oC
AUTO COOL
No
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
temperature is below 16oC, do not use it in the
2. Select operation mode
COOL button:Cooling mode
FAN button: Faning mode
DRY button: Dehumidify mode
Pi Pi
normal operation.
Continue to press the test operation
switch for more than 5 seconds. After
3.Select temp.setting
you hear the "Pi" sound twice,
release
button
Press
/
your finger from the switch: the cooling
Every time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will
decrease rapidly
Air Flow Direction Adjustment
Select a desired temperature.
1.Status display of air flow
4.Fan speed selection
Vertical flap
Press FAN button. For each press, fan speed
changes as follows:
Remote controller:
Display
Pos.1
(Auto swing)
Initial state
circulated
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
MED
HI
LOW
AUTO
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
2.Left and right air flow adjustment
For each press of
button, remote controller
displays as follows :
remote controller:
Remote
Controller
Operation
Mode
Pos.3
Pos.1
Pos.5
Pos.4
Pos.2
Pos.6
Note
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according
to room temperature.
AUTO
Cautions:
according to room temperature.
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or at air outlet if all vertical louvers are right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
COOL
DRY
In DRY mode, when room temperature becomes lower
than temp.setting+2o C, unit will run intermittently at LOW
speed regardless of FAN setting.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
mode ,
FAN
Note:
When restart after remote turning off, the remote controller
controller will automatically memorize the previous set swing position.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Operation
Sleep Operation
Note
When TIMER function is set, the sleeping function can’t be
set up .After the sleeping function is set up, if user resets
TIMER function, the sleeping function will be cancelled; the
machine will be in the state of timing-on.
Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep.
TURBO/QUIET Operation
TURBO/QUIET
TURBO/QUIET
Operation Mode
When you need fast cool or fast dehumidification,you can
choose the Turob function; when you sleep, read, you can
choose Quiet function
1. In COOL,DRY mode
1 hours after SLEEP mode starts,temp.will become OC
1
higher than temp.setting.After another 1 hours,temp.rises
by 1OC futher.The unit will run for further 6 hours then stops
T
emp. is higher than temp.setting so that room temperature
Press the
bu on, you can switch the “Turbo” and “Quiet”
TURBO/QUIET
won’t be too low for your sleep.
will swith as below
SLEEP operation starts
SLEEP operation stops
Approx.6hrs
(TURBO)
(QUIET)
cancel
Rises 1OC
1 hr
Rises 1OC
1 hr
When running in Turbo,the fan speed is the highest,
Temp.setting
Unit stop
when running in Quiet, the fan speed is super slow
In COOL, DRY mode
HEALTH Operation
In AUTO mode
2.
The unit operaters in corresponding sleep mode
Nano-Aqua generator adopt two high voltage
pole to ionize the water molecule into
nanometer water ion,and release these ions
to the air to kill the bacterium and refresh
the air. as well as the nanometer water inon
can be easily absorbed by skin,keeping moisture
anytime.
adapted to the automatically selected operation mode.
3. In FAN mode
It has no SLEEP function.
4.Set the wind speed change when sleeping
If the wind speed is high or middle before setting for the
sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Operation
Timer On/Off On-Off Operation
Health airflow Operation
1.Press
to starting
1.After unit starts, select your desired operation mode.
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press button to select “ Healthy airflow”, the remote
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
controller will switch as below
BLANK
Healthy
airflow
Healthy
airflow
downwarder
0.5h
0.5h
0.5h
TIMER ON-OFF
0.5h
TIMER OFF-ON
fixed
location
TIMER ON TIMER OFF
upwarder
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly,
stop for a minute and then start, adjusting by remote
controller.
3.Press
/
button to set time.
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Note:
1.After setting the healthy airflow function, the position
Press the button for each time, settiing time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
grill is fixed.
2.In cooling, it is better to select the
mode.
It can be adjusted within 24 hours.
3.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
4.Confirm timer setting
After adjust the time,press
button and confirm the
occur at the grille .
time ON or OFF button will not flash any more.
5.Cancel timer setting
Press the timer button by times until the time display
eliminated.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Maintenance
For Smart Use of The Air Conditioner
Remote Controller
Indoor Body
Setting of proper room
temperature
Do not block the air inlet
or outlet
Proper
temperature
wipe the air conditioner by using a
soft and dry cloth.For serious stains,
use a neutral detergent diluted with
water.Wring the water out of the
cloth before wiping,then wipe off the
detergent completely.
Do not usewater,wipe the controller
with a dry cloth.Do not use glass
cleaner or chemical cloth.
Do not use the following for cleaning
Close doors and windows
during operation
Use the timer effectively
O
O
Gasoline,benzine, thinner or cleanser Hot water over 40 C(104 F) may
may damage the coating of the unit.
cause discoloring or deformation.
During cooling operation
prevent the penetration
of direct sunlight with
curtain or blind
Air Filter cleaning
Open the inlet grille by pulling it upward.
Remove the filter.
Push up the filter's center tab slightly until it is
released from the stopper, and remove the filter downward.
Clean the filter.
If the unit is not to be used
for a long time, turn off the
power supply main switch.
Use the louvers effectively
Use a vacuum cleaner to remove dust, or wash the filter with
water.After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication
is facing to the front.Make sure that the filter is
completely
fixed behind the stopper.If theright
Once every
two weeks
and left filters are not attached correctly, that
may cause defects.
OFF
Close the inlet grille.
Replacement of Air Purifying Filter
1.Open the lnlet Grille
4.Attach the standard air filter
(Necessary installation)
Prop up the inlet grille by using a
small device named grille-support
which located in the right side of
the indoor unit.
ATTENTION:
The white side of the photocatalyst air purifying filter
face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face
outside,and the white side face the unit.
2.Detach the standard air filter
Slide the knob slightly upward to
release the filter, then withdraw it.
5.Close the Inlet Grille
Close the Grille surely
NOTE:
Detach old Air Purifying Filter
The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.
The bacteria-killing medium air purifying filter will be used
for a long time,no need for replacement. But in the period
of using them ,you should remove the dust frequently by
using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
3.Attach Air Purifying Filter
Put air purifying filter appliances into the
right and left filter frames.
Please keep the bacteria-killing medium air purifying filter in
the cool and dry conditions avoid long time directly sunshine
when you stop using it,or its ability of sterilization will be
reduced.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
Check proper
installation of the
drainage securely
Use an exclusive
power source
with a circuit
breaker
STRICT
OFF
STRICT
ENFORCEMENT
ENFORCEMENT
1.Do not use power supply cord extended
or connected in halfway
Connect power supply cord
to the outlet completely
Use the proper voltage
2.Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
to vapor or oil steam.
STRICT
ENFORCEMENT
STRICT
ENFORCEMENT
PROHIBITION
Take care not to damage
the power supply cord.
Do not use power supply
cord in a bundle.
Do not insert objects into the air
inlet or outlet.
PROHIBITION
PROHIBITION
PROHIBITION
Do not channel the air flow directly
at people, especially at infants or
the aged.
Do not start or stop the
operation by disconnecting
the power supply cord
and so on.
Do not try to repair or
reconstruct by yourself.
Connect the earth
cable.
earthing
PROHIBITION
PROHIBITION
CAUTION
Take fresh air occasionally especially
when gas appliance is running at the
same time.
Do not operate the switch with
wet hand.
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
STRICT
ENFORCEMENT
PROHIBITION
PROHIBITION
Do not pour water onto the unit
for cleaning
Do not install the unit near a fireplace
or other heating apparatus.
Check good condition of the
installation stand
PROHIBITION
PROHIBITION
PROHIBITION
Do not place flower vase or water
containers on the top of the unit.
Do not place any objects on or
climb on the unit.
Do not place animals or plants in
the direct path of the air flow
PROHIBITION
PROHIBITION
PROHIBITION
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Trouble shooting
Cautions
Before asking for service, check the following
first.
grille of the air
Do not obstruct or cover the ventilation
conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air conditioner.In no
case should children be allowed to sit on the outdoor unit.
Phenomenon
Cause or check points
When unit is stopped, it won't restart
immediately until 3 minutes have
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
will work for 3 minutes to protect the
air conditioner.
The system
does not restart
immediately.
Specifications
The refrigerating circuit is leak-proof.
The machine is adaptive in following situation
1.Applicable ambient temperature range:
During unit operation or at stop,
a swishing or gurgling noise may
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
generated by the casing expanding
or shrinking because of
32oC/23oC
Noise is heard
Maximum:D.B/W.B
Indoor
21oC/15oC
Minimum:D.B/W.B
Maximum:D.B/W.B 46oC/26oC
Cooling
Outdoor
Minimum:
18oC
D.B
Normal
Performance
inspection
temperature changes.
Should there be a big noise from
air flow in unit operation, air
filter may be too dirty.
2. If the power supply cord is damaged, it must be replaced by the
or its service agent or a similar
person.
manufacturer
qualified
This is because the system
circulates smells from the interior
air such as the smell of furniture,
paint, cigarettes.
Smells are
generated.
3.If the fuse of indoor unit on PC board is broken,please change
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
broken,change it with the type of T.25A/250V
Mist or steam are
blown out.
During COOL or DRY operation,
indoor unit may blow out mist.
This is due to the sudden cooling
of indoor air.
4. The wiring method should be in line with the local wiring standard.
5. After installation, the power plug should be easily reached.
6. The waste battery should be disposedproperly.
In DRY mode, when room temperature
becomes lower than temp.
setting+2 oC,unit will run
intermittently at LOW speed
regardless of FAN setting.
fan
In dry mode,
7. The appliance is not intended for use
speed can’t be
changed.
by young children or infirm
without supervision.
persons
8.Young children should be supervised to ensure that they do not play
with the appliance.
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
9. Please employ the proper power plug,which fit into the power supply
cord.
Is the air filter dirty?
Normally it should be cleaned
Poor cooling
every 15 days.
Multiple
check
must have acquired the local
The power plug and connecting cable
attestation.
10.
Are there any obstacles before
inlet and outlet?
Is temperature set correctly?
11.In order to protect the units,please turn off the A/C first,and at least
30 seconds later, cutting off the power.
Are there some doors or
windows left open?
Is there any direct sunlight
through the window during the
cooling operation?(Use curtain)
Are there too much heat sources
or too many people in the room
during cooling operation?
Haier
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
8
Download from Www.Somanuals.com. All Manuals Search And Download.
|