Operation  
Base Operation  
Emergency operation and test operation  
Emergency Operation:  
Use this operation only when the remote controller is defective  
or lost, and with function of emergency running, air conditoner  
can run automatically for a while.  
Remote controller  
When the emergency operation switch is pressed, the " Pi "  
sound is heard once, which means the start of this operation.  
When power switch is turning on for the first time and  
emergency operation starts, the unit will run automatically in  
the following modes:  
emergency  
Room  
Timer  
Designated  
Fan Operation  
mode  
operation switch  
temperature temperature mode speed  
Above 23oC  
Below 23oC  
26oC  
23oC  
AUTO COOL  
AUTO HEAT  
No  
No  
It is impossible to change the settings of temp. and fan speed,It  
is also not possible to operate in timer or dry mode.  
1. Unit start  
Press ON/OFF on the remote controller, unit starts.  
Test operation:  
2. Select operation mode  
COOL button:Cooling mode  
HEAT button: Heating mode  
DRY button: Dehumidify mode  
Test operation switch is the same as emergency switch.  
Use this switch in the test operation when the room  
temperature is below 16oC, do not use it in the  
normal operation.  
Continue to press the test operation  
switch for more than 5 seconds. After  
test operation  
switch  
3.Select temp.setting  
button  
you hear the "Pi" sound twice,  
release  
Press  
your finger from the switch: the cooling  
Every time the button is pressed, temp.setting  
increase 1oC,if kept depressed, it will increase  
rapidly  
operation starts with the air flow speed "Hi".  
Under this operation mode,the fan motor of indoor  
unit will run in high speed.  
Every time the button is pressed, temp.setting  
decrease 1oC,if kept depressed, it will  
decrease rapidly  
Air Flow Direction Adjustment  
1.Status display of air flow  
Select a desired temperature.  
4.Fan speed selection  
Press FAN button. For each press, fan speed  
changes as follows:  
Pos.1  
Pos.2  
Pos.3  
Pos.4  
Pos.5  
Pos.6  
(Auto swing)  
Remote controller:  
Display  
circulated  
cooling mode:from pos.1 to pos.4 and pos.6  
heating mode:from pos.5 to pos.1 and pos.6  
MED  
HI  
LOW  
AUTO  
2.Left and right air flow adjustment(manual)  
Move the vertical blade by a knob on air conditioner  
to adjust left and right direction referring to Fig.  
Air conditioner is running under displayed fan speed.  
When FAN is set to AUTO, the air conditioner  
automatically adjusts the fan speed according to room  
temperature.  
Remote  
Controller  
Operation  
Mode  
Note  
ꢁ'  
Under the mode of auto operation, air conditioner will  
automatically select Cool or Heat operation according to  
room temperature. When FAN is set to AUTO the air  
conditioner automatically adjusts the fan speed according  
to room temperature.  
Cautions:  
AUTO  
When adjusting the flap by hand,turn off the unit.  
When humidity is high,condensate water might occur  
at air outlet if all vertical louvers are adjusted to left or  
right.  
COOL  
DRY  
In DRY mode, when room temperature becomes lower  
than temp.setting+2o C, unit will run intermittently at LOW  
speed regardless of FAN setting.  
It is advisable not to keep horizontal flap at downward  
In HEAT mode, warm air will blow out after a short  
period of the time due to cold-draft prevention function.  
When FAN is set to AUTO, the air conditioner automatically  
adjusts the fan speed according to room temperature.  
mode ,  
position for a long time in COOLor DRY  
HEAT  
FAN  
otherwise, condensate water might occur.  
Note:  
In FAN operation mode , the unit will not operate in COOL or  
HEAT mode but only in FAN mode, AUTO is not available in  
FAN mode. And temp. setting is disabled. In FAN mode,  
sleep operation is not available.  
When restart after remote turning off, the remote  
controller will automatically memorize the previous  
set swing position.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Sleep Operation  
4. In FAN mode  
It has no SLEEP function.  
Press  
cycle display to  
button to enter additional options, when  
will flash. And then press  
5.Set the wind speed change when sleeping  
If the wind speed is high or middle before setting for the  
sleep, set for lowing the wind speed after sleeping.  
If it is low wind, no change.  
,
enter to sleep function.  
Note  
When TIMER function is set, the sleeping function can’t be  
set up .After the sleeping function is set up, if user resets  
TIMER function, the sleeping function will be cancelled; the  
machine will be in the state of timing-on.  
POWER/QUIET Operation  
(1)  
POWER Operation  
Operation Mode  
When you need rapid heating or cooling, you can use this function.  
1. In COOL,DRY mode  
1 hour after SLEEP mode starts,temp.will become OC  
1
Press  
button to enter additional options, when cycle  
will flashand then press ,enter to  
higher than temp.setting.After another 1 hours,temp.rises  
display to  
,
O
by 1 C futher.The unit will run for further 6 hours then stops  
power function. When cancel the function, please enter  
additional options again and to cancel power function.  
Temp. is higher than temp.setting so that room temperature  
won’t be too low for your sleep.  
(2)  
SLEEP operation starts  
SLEEP operation stops  
Approx.6hrs  
QUIET Operation  
You can use this function when silence is needed for rest or reading.  
Press QUIET button, the remote controller will show  
and then achieve to the quiet function. Press again this  
QUIET button , the quiet function will be cancelled.  
,
Rises 1OC  
1 hr  
Rises 1OC  
1 hr  
Temp.setting  
Unit stop  
Note ˖  
In COOL, DRY mode  
During POWER operation, in rapid HEAT or COOL mode ,  
the room will show inhomogeneous temperature distribution.  
Long period QUIET operation will cause effect of not too  
cool or not too warm.  
In HEAT mode  
2.  
O
1 hours after SLEEP mode starts,temp will become 2 C  
lower than temp.setting.After another 1 hours,temp  
decrease by 2OC futher.After more another 3 hours,temp.  
OC  
rises by 1 futher.The unit will run for further 3 hours then  
stops.Temp.is lower than temp. setting so that room  
temperature won’t be too high for your sleep.  
Temp.setting  
Unit stop  
O
1 hr  
Decreases 2 C  
1 hr  
O
Decreases 2 C  
3 hrs  
O
Rises 1 C  
3 hrs  
SLEEP  
SLEEP  
operation stops  
operation starts In HEAT mode  
In AUTO mode  
3.  
The unit operaters in corresponding sleep mode  
adapted to the automatically selected operation mode.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
EUROPEAN REGULATIONS  
Operation  
CONFORMITY FOR THE MODELS  
CE  
Timer On/Off On-Off Operation  
All the products are in conformity with the following  
European provision:  
1.After unit starts, select your desired operation mode.  
2.Press TIMER button to change TIMER mode. Every  
time the button is pressed, display changes as follows:  
Remote controller:  
- Low Voltage Directive 73/23/EEC  
- Low Voltage Directive 2006/95/EC  
-Electomagnetic CompatibilitY 89/336/EEC  
-Electomagnetic CompatibilitY 2004/108/EC  
ROHS  
BLANK  
0.5h  
0.5h  
0.5h  
0.5h  
TIMER OFF-ON  
TIMER ON TIMER OFF  
TIMER ON-OFF  
The products are fulfilled with the requirements in the  
directive 2002/95/EEC of the European parliament and of  
council on the Restriction of the use of Certain Hazardous  
Substances in Electrical and Electronic Equipment (EU  
RoHS Directive)  
Then select your desired TIMER mode (TIMER ON or  
TIMER OFF or TIMER ON-OFF). " "or " "will flash.  
3.Press button to set time.  
/
Press the button for each time, setting time in the first  
12 hours increased by 0.5 hour every time, after 12  
hours,increased by 1 hour every time.  
WEEE  
In accordance with the directive 2002/96/CE of the European  
parliament, herewith we inform the consumer about the dis-  
posal requirements of the electrical and electronic products.  
Press the button for each time, settiing time in the first  
12 hours decreased by 0.5 hour every time, after 12  
DISPOSAL REQUIREMENTS:  
hours,decreased by 1 hour every time.  
It can be adjusted within 24 hours.  
Your air conditioning product is marked with this  
symbol.This means that electrical and electronic  
products shall not be mixed with unsorted  
4.Confirm timer setting  
After adjust the time,press  
button and confirm the  
household waste. Do not try to dismantle the  
time ON or OFF button will not flash any more.  
system yourself : the dismantling of the air  
5.Cancel timer setting  
conditioning system,treatment of the refrigerant, of oil and of  
other part must be done by a qualified installer in accordance  
with relevant local and national legislation. Air conditioners  
must be treated at a specialized treatment facility for reuse,  
recycling and recovery. By ensuring this product is disposed  
of correctly, you will help to prevent potential negative cons-  
equences for the environment and humen health. Please  
contact the installer or local authority for more information.  
Battery must be removed from the remote controller and dis-  
posed of separately in accordance with relevant local and  
nationl legislation.  
Press the timer button by times until the time display  
eliminated.  
Hints:  
After replacing batteries or a power failure happens, time  
setting should be reset.  
According to the Time setting sequence of TIMER ON or  
TIMER OFF, either Start-Stop or Stop-Start can be achieved.  
Healthy airflow Operation  
1.Press  
to starting  
Setting the comfort work conditions.  
2.The setting of healthy airflow function  
IMPORTANT INFORMATION REGA-  
RDING THE REFRIGERANT USED  
Press  
button to enter additional options,Press this  
button continuously, the louvers location will cycle between  
in the following three locations, to choose the swing location  
Contains fluorinated greenhouse gases  
covered by the Kyoto Protocol  
A
what you needed,and then press  
button to confirm.  
1=  
kg  
kg  
R410A  
B
C
Healthy  
airflow  
upwarder  
Healthy  
Present  
position  
2
2=  
airflow  
downwarder  
1
1+2=  
kg  
3.The cancel of the healthy airflow function  
D
F
E
Press  
button to enter additional options,Press this  
This product contains fluorinated greenhouse gases covered by  
the Kyoto Protocol. Do not vent into the atmosphere.  
Refrigerant type:R410A  
button continuously, the louvers location will cycle between  
in the following three locations again,and then press  
button to cancel.  
Notice: Do not direct the flap by hand. Otherwise, the  
grille will run incorrectly. If the grille is not run correctly, stop  
for a minute and then start, adjusting by remote  
controller.  
GWP* value:1975  
GWP=global warming potential  
Please fill in with indelible ink,  
• 1  
• 2  
the factory refrigerant charge of the product  
the additional refrigerant amount charged in the field and  
• 1+2 the total refrigerant charge  
on the refrigerant charge label supplied with the product.  
The filled out label must be adhered in the proximity of the product  
charging port (e.g. onto the inside of the stop value cover).  
A contains fluorinated greenhouse gases covered by the Kyoto  
Protocol  
Note:  
1.After setting the healthy airflow function, the position  
grill is fixed.  
2.In heating, it is better to select the  
3.In cooling, it is better to select the  
mode.  
mode.  
B factory refrigerant charge of the product: see unit name plate  
C additional refrigerant amount charged in the field  
D total refrigerant charge  
4.In cooling and dry, using the air conditioner for a long  
time under the high air humidity, condensate water may  
occur at the grille .  
E outdoor unit  
F refrigerant cylinder and manifold for charging  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
For Smart Use of The Air Conditioner  
Remote Controller  
Indoor Body  
Setting of proper room  
temperature  
Do not block the air inlet  
or outlet  
Proper  
temperature  
wipe the air conditioner by using a  
soft and dry cloth.For serious stains,  
use a neutral detergent diluted with  
water.Wring the water out of the  
cloth before wiping,then wipe off the  
detergent completely.  
Do not usewater,wipe the controller  
with a dry cloth.Do not use glass  
cleaner or chemical cloth.  
Do not use the following for cleaning  
Close doors and windows  
during operation  
Use the timer effectively  
O
O
Gasoline,benzine, thinner or cleanser Hot water over 40 C(104 F) may  
may damage the coating of the unit.  
cause discoloring or deformation.  
During cooling operation  
prevent the penetration  
of direct sunlight with  
curtain or blind  
Air Filter cleaning  
Open the inlet grille by pulling it upward.  
Remove the filter.  
Push up the filter's center tab slightly until it is  
released from the stopper, and remove the filter downward.  
Clean the filter.  
If the unit is not to be used  
for a long time, turn off the  
power supply main switch.  
Use the louvers effectively  
Use a vacuum cleaner to remove dust, or wash the filter with  
water.After washing, dry the filter completely in the shade.  
Attach the filter.  
Attach the filter correctly so that the "FRONT" indication  
is facing to the front.Make sure that the filter is  
completely  
fixed behind the stopper.If theright  
Once every  
two weeks  
and left filters are not attached correctly, that  
may cause defects.  
OFF  
Close the inlet grille.  
Replacement of Air Purifying Filter  
1.Open the lnlet Grille  
Hold the front panel by the tabs on  
the both sides and lift it until it stops  
with a click.  
4.Attach the standard air filter  
(Necessary installation)  
ATTENTION:  
The white side of the photocatalyst air purifying filter  
face outside,and the black side face the unit The green  
side of the bacteria-killing medium air purifying filter face  
outside,and the white side face the unit.  
2.Detach the standard air filter  
Slide the knob slightly upward to  
release the filter, then withdraw it.  
5.Close the Inlet Grille  
Close the Grille surely  
NOTE:  
Detach old Air Purifying Filter  
The photocatalyst air purifying filter will be solarized in fixed  
time. In normal family, it will be solarized every 6 months.  
But it is not fit for washing by water and other scour.  
The bacteria-killing medium air purifying filter will be used  
for a long time,no need for replacement. But in the period  
of using them ,you should remove the dust frequently by  
using vacuum cleaner or flaping them lightly,otherwise ,  
its performance will be affected.  
Please keep the bacteria-killing medium air purifying filter in  
the cool and dry conditions avoid long time directly sunshine  
when you stop using it,or its ability of sterilization will be  
reduced.  
3.Attach Air Purifying Filter  
Put air purifying filter appliances into the  
right and left filter frames.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cautions  
WARNING  
Please call Sales/Service Shop for the Installation.  
Do not attempt to install the air conditioner by yourself because improper works  
may cause electric shock, fire, water leakage.  
WARNING  
When abnormality such as burnt-small found,  
immediately stop the operation button and  
contact sales shop.  
Check proper  
installation of the  
drainage securely  
Use an exclusive  
power source  
with a circuit  
breaker  
STRICT  
OFF  
STRICT  
ENFORCEMENT  
ENFORCEMENT  
1.Do not use power supply cord extended  
or connected in halfway  
Connect power supply cord  
to the outlet completely  
Use the proper voltage  
2.Do not install in the place where there is any  
possibility of inflammable gas leakage around the unit.  
3.Do not get the unit exposed  
to vapor or oil steam.  
STRICT  
STRICT  
ENFORCEMENT  
ENFORCEMENT  
PROHIBITION  
Take care not to damage  
Do not use power supply  
Do not insert objects into the air  
inlet or outlet.  
the power supply cord.  
cord in a bundle.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not channel the air flow directly  
at people, especially at infants or  
the aged.  
Do not start or stop the  
operation by disconnecting  
the power supply cord  
and so on.  
Do not try to repair or  
reconstruct by yourself.  
Connect the earth  
cable.  
earthing  
PROHIBITION  
PROHIBITION  
CAUTION  
Take fresh air occasionally especially  
when gas appliance is running at the  
same time.  
Do not operate the switch with  
wet hand.  
Do not use for the purpose of storage of  
food, art work, precise equipment,  
breeding, or cultivation.  
STRICT  
ENFORCEMENT  
PROHIBITION  
PROHIBITION  
Do not pour water onto the unit  
Do not install the unit near a fireplace  
Check good condition of the  
installation stand  
for cleaning  
or other heating apparatus.  
PROHIBITION  
PROHIBITION  
PROHIBITION  
Do not place flower vase or water  
containers on the top of the unit.  
Do not place any objects on or  
climb on the unit.  
Do not place animals or plants in  
the direct path of the air flow  
PROHIBITION  
PROHIBITION  
PROHIBITION  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble shooting  
Cautions  
conditoner.Do not put fingers or any other things into the  
inlet/outlet and swing louver.  
Before asking for service, check the following  
first.  
grille of the air  
Do not obstruct or cover the ventilation  
Phenomenon  
Cause or check points  
Do not allow children to play with the air conditioner.In no  
case should children be allowed to sit on the outdoor unit.  
When unit is stopped, it won't restart  
immediately until 3 minutes have  
elapsed to protect the system.  
When the electric plug is pulled out  
and reinserted, the protection circuit  
will work for 3 minutes to protect the  
air conditioner.  
During unit operation or at stop,  
a swishing or gurgling noise may  
be heard.At first 2-3 minutes after  
unit start, this noise is more noticeable.  
(This noise is generated by  
The system  
does not restart  
immediately.  
Specifications  
The refrigerating circuit is leak-proof.  
The machine is adaptive in following situation  
1.Applicable ambient temperature range:  
Noise is heard  
32oC/23oC  
Maximum:D.B/W.B  
Minimum:D.B/W.B  
Maximum:D.B/W.B 4oC/26oC  
Indoor  
21oC/15oC  
refrigerant flowing in the system.)  
During unit operation, a cracking  
noise may be heard.This noise is  
generated by the casing expanding  
or shrinking because of  
Cooling  
Heating  
Outdoor  
Indoor  
Minimum:  
18oC  
D.B  
27oC  
Maximum:D.B  
Minimum: D.B  
Normal  
Performance  
inspection  
15oC  
temperature changes.  
Maximum:D.B/W.B 24oC/18oC  
Should there be a big noise from  
air flow in unit operation, air  
filter may be too dirty.  
Outdoor  
Minimum:D.B/W.B 7oC/-8oC  
-
Maximum:D.B/W.B 24oC/18oC  
Outdoor  
This is because the system  
circulates smells from the interior  
air such as the smell of furniture,  
paint, cigarettes.  
(INVERTER)  
Minimum:D.B  
-15oC  
Smells are  
generated.  
2. If the power supply cord is damaged, it must be replaced by the  
or its service agent or a similar  
person.  
Mist or steam are  
blown out.  
manufacturer  
qualified  
During COOL or DRY operation,  
indoor unit may blow out mist.  
This is due to the sudden cooling  
of indoor air.  
3.If the fuse of indoor unit on PC board is broken,please change  
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is  
broken,change it with the type of T.25A/250V.  
The fuse is must be replaced by the manufacturer or its service  
agent or a similar qualified person.  
In DRY mode, when room temperature  
becomes lower than temp.  
setting+2 oC,unit will run  
intermittently at LOW speed  
regardless of FAN setting.  
fan  
In dry mode,  
speed can’t be  
changed.  
4. The wiring method should be in line with the local wiring standard.  
5. The waste battery should be disposedproperly.  
The circuit breaker switch is "ON",but  
not "off"?  
Is there a power failure?  
Is fuse blownout?  
6.This appliance is not intended for use by persons (including  
children) with reduced physical, sensory or mental capabilities, or  
lack of experience and knowledge, unless they have been given  
supervision or instruction concerning use of appliance by a person  
responsible for their safety.  
Is the air filter dirty?  
Normally it should be cleaned  
every 15 days.  
Poor cooling  
Multiple  
check  
Are there any obstacles before  
inlet and outlet?  
Is temperature set correctly?  
7. Children should be supervised to ensure that they do not play with  
the appliance.  
Are there some doors or  
windows left open?  
Is there any direct sunlight  
through the window during the  
cooling operation?(Use curtain)  
Are there too much heat sources  
or too many people in the room  
during cooling operation?  
8.In order to protect the units,please turn off the A/C first,and at least  
30 seconds later, cutting off the power.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Harbor Freight Tools Wheelchair 45735 User Manual
Harman Kardon DVD Player DVD 506 User Manual
Hatco Food Warmer FR2 Series User Manual
Honeywell Air Conditioner W8835 User Manual
Hotpoint Dishwasher FDD 914 User Manual
HP Hewlett Packard Photo Printer D7200 User Manual
HP Hewlett Packard Sprinkler 54500 User Manual
Humminbird Fish Finder 200DX User Manual
Husqvarna Trimmer 326C User Manual
Ice O Matic Ice Maker ICE0500 User Manual