HP GbE2c Ethernet Blade Switch for
c-Class BladeSystem
User Guide
May 2006 (First Edition)
Part Number 418116-001
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Introduction.................................................................................................................................. 6
Overview................................................................................................................................................. 6
Features................................................................................................................................................... 6
Configuration and management........................................................................................................ 8
Redundant crosslinks........................................................................................................................ 9
Redundant paths to server bays....................................................................................................... 10
NTP............................................................................................................................................. 12
RADIUS........................................................................................................................................ 12
Redundant images in firmware........................................................................................................ 14
Connectors................................................................................................................................... 15
Installing the switch..................................................................................................................... 16
Configuring multiple switches.......................................................................................................... 18
Accessing the switch................................................................................................................................ 19
Logging on and configuring the switch....................................................................................................... 20
Contents
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing an existing switch..................................................................................................................... 22
Cables................................................................................................................................................... 24
BSMI notice............................................................................................................................................ 25
SNMP MIBs support.................................................................................................................... 42
Electrostatic discharge................................................................................................................. 45
Preventing electrostatic discharge.............................................................................................................. 45
Grounding methods to prevent electrostatic discharge.................................................................................. 45
Troubleshooting.......................................................................................................................... 47
Forgotten administrator user name and password that was configured on the switch........................................ 47
Health LED on the switch stays amber for more than 30 seconds and switch does not boot............................... 48
Cannot access the switch serial console interface using null modem connection from a PC Terminal Emulation
The port activity LEDs continuously indicate activity after connecting more than one port to another switch or
Contents
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Cannot connect to the switch remotely using the Web interface..................................................................... 50
The switch does not let the user enable two adjacent ports into two different VLANs while assigning the ports to
While using TFTP to download firmware, the switch fails to connect to the TFTP server, or after connection the
download fails........................................................................................................................................ 51
The switch fails to connect to the TFTP server while using TFTP to download or upload a configuration file, or after
connection the download or upload fails.................................................................................................... 51
The console screen displays a message to change the baud rate for the terminal emulation session for XModem
Contents
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
In this section
Overview ................................................................................................................................................ 6
Additional references................................................................................................................................ 6
Features .................................................................................................................................................. 6
Switch architecture ................................................................................................................................... 9
Supported technologies........................................................................................................................... 10
External components............................................................................................................................... 14
Overview
This user guide provides installation and reference information for the HP GbE2c Ethernet Blade Switch
for c-Class BladeSystem.
Additional references
Configure the switch after installation. Detailed information about how to configure the switch is available
in the reference guides listed below. To obtain these guides, see the HP website
•
•
•
•
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based Interface Reference Guide
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Quick Setup Instructions
The HP GbE2c Ethernet Blade Switch for c-Class BladeSystem interconnect kit contains one switch.
The switch uses Gigabit Layer 2 switching technology to provide between 16-to-1 to 16-to-5 reduction in
the number of networking cables per BL c-Class server blade enclosure.
Each switch reduces sixteen server networking ports to one to five uplink Gigabit ports.
Features
The switch is designed for easy installation and high performance in an environment where traffic on the
network and the number of users increases continually.
Enterprise class performance
The switch features include:
•
Up to a 16-to-1 reduction in networking cables and connections, concentration of sixteen Gigabit
Ethernet server ports down to as little as one Gigabit Ethernet port, or up to five Gigabit Ethernet
uplink ports for additional bandwidth and redundant connections to the network backbone
Introduction
6
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Fully supported on the HP c-Class BladeSystem server blade enclosure and infrastructure compatible
with any combination of HP c-Class BladeSystem server blades
Ability to replace an existing switch without having to power down the server blades or the server
blade enclosure
•
•
Pre-configured for immediate use with the HP c-Class BladeSystem server blade enclosure
System security including SSH, SCP, 255 port-based IEEE 802.1Q tagged VLANs per switch,
RADIUS user authentication and authorization, or TACACS+ AAA
•
•
•
•
An extensive list of industry standard protocol support, compatible with widely-used networking
components
9K jumbo frames that improve performance by increasing application throughput and decreasing
server processor utilization
Robust configuration and management from any switch port using the included browser-based and
scriptable command line user interfaces
Support for Telnet, SNMP, SCP, FTP, and TFTP file transfer, human read/write configuration file,
XModem, and an extensive list of MIB objects further enhance the management capabilities
•
•
•
Fully redundant end-to-end architecture maximizing server availability from the network
Support for IGMP snooping for multicasting
Support for UFD for network path resiliency. It works in conjunction with NIC teaming functionality
that is supported on the blade servers. This feature tracks the link state on uplink ports. When an
uplink port goes down or is in STP blocking state, this feature will enable the switch to auto disable
the downlinks which are connected to the blade server NICs. This enables NIC teaming software to
detect link failure on the primary NIC port and fail over to the secondary NIC in the team. As a
result, the secondary path is enabled for continued blade server access.
When used in conjunction with UFD, NIC teams on the blade server must be configured for switch
redundancy. That is, the team will span ports on both Switch 1 and Switch 2. See the HP network
adapter teaming: load balancing in ProLiant servers running Microsoft Windows operating systems
white paper for additional information. To locate this white paper:
b. Enter "nic" in the product search box.
c. A product list displays. Select one of the NIC products.
d. Select the "Manuals" link to display the documentation list. This white paper will be under the
"White papers" category.
•
RMON feature, which allows network devices to exchange network monitoring data. RMON
performs these major functions:
•
•
•
Gathers cumulative statistics for Ethernet interfaces
Tracks a history of statistics for Ethernet interfaces
Creates and triggers alarms for user-defined events
•
•
•
•
•
An administrator can define end user accounts that permit limited access to the switch. The switch
requires username/password authentication for end users.
Fast Uplink Convergence that enables the switch to quickly recover from the failure of the primary
link or trunk group in a Layer 2 network using Spanning Tree Protocol.
Support for SSH version 2. SSH is a protocol that enables remote administrators to log securely into
the switch over a network to execute management commands.
Switch software provides SNMP support for access through any network management software, such
as HP OpenView.
Support for HTTP software upgrade using the BBI. FTP or TFTP server is not required to perform a
software upgrade.
Introduction
7
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
Port Fast Forwarding that allows a port that participates in Spanning Tree to bypass the Listening and
Learning states and enter directly into the Forwarding state.
Allows secure browser access (HTTPS) to management functions
Switch redundancy
In a dual switch configuration, the switches offer several redundancy and failover features. With these
features, the network configuration is designed to allow for continued network access to each server
blade in case of a component or link failure. The switch redundancy and failover features include:
•
•
Up to eight separate switches per one HP c-Class BladeSystem server blade enclosure
Five Gigabit Ethernet uplink ports, per switch, for designing fully meshed uplink paths to the network
backbone
•
Server networking connections routed to each of the separate switches for redundant paths to
tolerate a switch or port malfunction
•
•
Redundant data path Gigabit Ethernet cross connections between switches
STP support that eliminates potential problems caused by redundant networking paths and provides
for failover with a secondary path in case of primary path failure; supports IEEE 802.1D Spanning
Tree Protocol and is compatible with Cisco® PVST+ and Cisco PVST, when the other device is
configured as untagged or configured to use 802.1q tagging. The switch also supports IEEE 802.1s
MSTP and IEEE 802.1w RSTP.
•
•
•
Redundant power supplies and redundant cooling fans within the server blade enclosure
Redundant firmware images and configuration settings on switch flash memory
Redundant, configurable DNS clients, syslog servers, gateways, and community strings and SNMP
trap manager hosts
Configuration and management
The switch provides these configuration and management interfaces and tools:
•
•
A scriptable CLI allows local, Telnet, or SSH access.
A BBI allows remote access using a Web browser such as Microsoft® Internet Explorer or Netscape
Navigator.
•
•
SNMP manageability and monitoring are supported.
The switch functionality allows uploading and downloading of switch configurations through TFTP
and SCP, thus allowing the rapid deployment of multiple server blade systems, and providing robust
backup and restore capabilities.
•
•
NTP is supported, allowing the switch to display and record the accurate date and time as provided
by an NTP server.
Two firmware images, either of which can be selected to be the current runtime image, can be held
in memory.
•
•
RADIUS provides support for user authentication and authorization.
TACACS+ provides support for Cisco TACACS+ server compatible authentication, authorization,
and accounting.
•
•
•
The user interfaces provide multi-level password protected user accounts.
IP settings are set manually or obtained automatically from a BOOTP server.
A text-based, human read/write configuration file provides viewing, printing, and editing
capabilities.
•
•
A DNS client supports primary and secondary DNS servers.
Any port can be enabled or disabled as desired.
Introduction
8
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Any switch port can be used to perform switch management and PXE.
Diagnostic tools
The hardware, software, and firmware diagnostic tools that are available include:
•
•
•
•
•
•
•
HP Systems Insight Manager automatic discovery and identification
POST built into the switch boot process
Switch port mirroring
Switch LED panel displaying per port status and speed
System, management, and option compatibility status LEDs
Rear panel reset power switch and DB-9 management serial port
Statistic monitoring including port utilization, data packets received/transmitted, port error packets,
trunk utilization, and so on
•
•
•
•
•
•
Ping and trace route capability
Remote syslog with support for primary and secondary syslog server
The ability to return the switch to known good condition in case of firmware corruption
State information dump for tuning and debugging switch performance
Panic command for immediate state dump to flash memory and automatic switch boot
Ability to set NVRAM diagnostic flags
Switch architecture
The HP c-Class BladeSystem provides Ethernet switching technology for network cable reduction.
The switch does not affect or determine NIC enumeration and the associated mapping of NIC interfaces
to switch ports. The numbering of the NICs on the server (for example, NIC 1, NIC 2, NIC 3) is
determined by the server type, the server operating system, and what NICs are enabled on the server.
Port Mapping
For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the HP
BladeSystem enclosure setup and installation guide on the HP website
Dual switches
In a dual switch configuration, two switches in the server blade enclosure provide switch redundancy and
redundant paths to the network ports on the server blades. Each switch has five external Gigabit Ethernet
ports and sixteen internal Gigabit Ethernet ports providing connectivity to the blade servers within the
enclosure.
Each pair of switches consolidates up to thirty-two Gigabit Ethernet signals into one-to-ten Gigabit ports
(on the back of the enclosure).
Redundant crosslinks
In a dual switch configuration, the two switches are connected through redundant Gigabit crosslinks.
These two crosslinks provide an aggregate throughput of 2 Gb/s for traffic between the switches.
These crosslinks are disabled by default. The crosslinks must be enabled for use.
Introduction
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Redundant paths to server bays
In a dual switch configuration, redundant Ethernet signals from each blade server are routed through the
enclosure backplane to separate switches within the enclosure. This configuration provides redundant
paths to each server bay.
Redundant Ethernet signals from each blade server are routed through the enclosure backplane to
separate switches within the enclosure. However, specific switch port to server mapping varies depending
on which type of server blade is installed.
On a heavily used system, using a single uplink port for 32 Ethernet signals causes a traffic bottleneck.
For optimum performance, HP recommends using at least one uplink port per switch.
Supported technologies
Layer 2 switching
The switch uses Gigabit Layer 2 switching technology. Layer 2 refers to the Data Link layer of the OSI
model, which is concerned with moving data packets across a network by enforcing CSMA/CD. This
layer performs:
•
•
•
•
•
Ethernet packet framing
MAC addressing
Physical medium transmission error detection
Medium allocation (collision avoidance)
Contention resolution (collision handling)
Layer 2 switching technology allows the switch to look into data packets and redirect them based on the
destination MAC address. This reduces traffic congestion on the network because packets, instead of
being transmitted to all ports, are transmitted to the destination port only.
IEEE 802.1 Q-based VLAN
The switch provides support for a total of 255 IEEE 802.1Q VLANs for server grouping and isolation. A
VLAN is a network segment configured according to a logical scheme rather than a physical layout.
VLANs are used to combine any collection of LAN segments into an autonomous user group that appears
as a single LAN.
VLANs also logically segment the physical network into different broadcast domains so that packets are
forwarded only between ports within the VLAN. This technology enhances performance by conserving
bandwidth and improves security by limiting traffic to specific domains. For example, isolate the server
blade iLO ports from the rest of the NICs. The iLO ports on Switch 2 are assigned to their own VLAN and
go to a dedicated uplink or share an uplink using VLAN tagging.
IMPORTANT: The greater the number of VLANs, the greater the switch CPU utilization. For maximum
switch performance, HP recommends being judicious when configuring the number of VLANs.
NOTE: VLAN 4095 is reserved for future functionality.
Spanning Tree Protocol
The switch supports IEEE 802.1D STP, which allows the blocking of links that form loops between switches
in a network. When multiple links between switches are detected, a primary link is established.
Duplicated links are blocked from use and become standby links. If the primary link fails, the standby link
is activated.
Introduction 10
Download from Www.Somanuals.com. All Manuals Search And Download.
In addition, the switch provides a spanning tree domain per VLAN. The switch is compatible with Cisco®
PVST+ and Cisco PVST, when the other device is configured as untagged or configured to use 802.1q
tagging. Sixteen spanning tree domains are supported per switch.
NOTE: STP 16 is reserved for future functionality.
The switch also provides IEEE 802.1s-based MSTP and IEEE 802.1w-based RSTP.
SNMP
The switch is configured and monitored remotely from an SNMP-based network management station. The
switch supports industry-standard SNMP MIBs and proprietary HP enterprise switch MIBs for fault
detection and monitoring of switch functionality. In addition, the switch supports various environmental
traps such as temperature and fan failure traps.
To secure the management interface, the switch administrator configures community strings with two levels
of access: Read and Read/Write. Access to the switch is also restricted to only management stations that
are members of a specific IP network. This is achieved by configuring the address/mask of that specific
network as a restricted management network address/mask.
Port mirroring
The switch allows mirroring of one or multiple ports (source ports) to another port (destination port) for
network monitoring and troubleshooting purposes. This technology offers a way for network packet
analyzers to view the traffic moving through the switch by providing a copy of the traffic that is currently
being passed through any other port. The packets are sent to a network packet analyzer or other
monitoring device attached to the mirror port.
Port trunking and load balancing
The switch supports EtherChannel compatible IEEE 802.3ad (without LACP) port trunking allowing several
ports to be grouped together and act as a single logical link called a trunk. This feature provides a
bandwidth that is a multiple of the bandwidth of a single link. It also improves reliability since load
balancing is automatically applied to the ports in the trunked group. A link failure within the group causes
the network traffic to be directed to the remaining links in the group.
TFTP support
TFTP support allows the switch firmware to be upgraded by downloading a new firmware file from a TFTP
server to the switch. Firmware images of the switch are also uploaded to a TFTP server, a configuration
file is downloaded into a switch from a TFTP server, and configuration settings are saved to the TFTP
server.
Store and forward switching scheme
The switch provides a store and forward switching scheme that allows each packet to be buffered (stored)
before it is forwarded to its destination. While this method creates latency, it improves reliability in a
heavily used switch. Packets that cannot be forwarded are saved immediately, rather than dropped, so
that packets behind them are less likely to be dropped in periods of heavy usage.
BOOTP
By default, the switch is configured to obtain an IP address from a BOOTP server during the boot process.
The IP settings are also manually configured by means of the serial interface. The IP settings are
Introduction 11
Download from Www.Somanuals.com. All Manuals Search And Download.
configurable from the browser-based interface, but because the connection is based on an IP address for
these interfaces, users will have to reconnect with the newly assigned IP address.
NTP
The switch maintains the current date and time. This information displays on the management interfaces
and is used to record the date and time of switch events. Current date and time information are manually
set on the switch or are obtained through NTP. NTP allows the switch to send a request to a primary NTP
server in each polling period asking for GMT.
RADIUS
The switch supports the RADIUS method to authenticate and authorize remote administrators for managing
the switch. This method is based on a client/server model. The RAS, the switch, is a client to the back-end
database server. A remote user (the remote administrator) interacts only with the RAS, not the back-end
server and database.
RADIUS authentication consists of:
•
•
•
A protocol with a frame format that utilizes UDP over IP, based on RFC 2138 and 2866
A centralized server that stores all the user authorization information
A client, in this case, the switch
The switch, acting as the RADIUS client, communicates to the RADIUS server to authenticate and authorize
a remote administrator using the protocol definitions specified in RFC 2138 and 2866. Transactions
between the client and the RADIUS server are authenticated using a shared key that is not sent over the
network. In addition, the remote administrator passwords are sent encrypted between the RADIUS client
(the switch) and the back-end RADIUS server.
The benefits of using RADIUS are:
•
•
•
•
Authentication of remote administrators
Identification of the administrator using name/password
Authorization of remote administrators
Determination of the permitted actions and customizing service for individual administrators
TACACS+
The switch supports the TACACS+ method to authenticate, authorize, and account for remote
administrators managing the switch. This method is based on a client/server model. The switch is a client
to the back-end TACACS+ AAA server. A remote user (the remote administrator) interacts only with the
client, and not with the back end AAA server.
The TACACS+ AAA method consists of:
•
•
A protocol with a frame format that utilizes TCP over IP
A centralized AAA server that stores all the user authentication, authorization, and accounting (of
usage) information
•
A NAS or client (in this case, the switch)
The switch, acting as the TACACS+ client or NAS, communicates to the TACACS+ server to authenticate,
authorize, and account for user access. Transactions between the client and the TACACS+ server are
authenticated using a shared key that is not sent over the network. In addition, the remote administrator
passwords are sent encrypted between the TACACS+ client (the switch) and the back-end TACACS+
server.
The switch supports:
Introduction 12
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
Only standard ASCII inbound login authentication. PAP, CHAP, or ARAP login methods are not
supported. One-time password authentication is also not supported.
Authorization privilege levels of only 0, 3, and 6. These map to management levels of user, oper,
and admin, respectively.
The accounting attributes of protocol, start_time, stop_time, and elapsed_time. For BBI users,
accounting stop records are only sent if the user presses the QUIT button.
SSH and SCP
SSH and SCP use secure tunnels to encrypt and secure messages between a remote administrator and the
switch. Telnet does not provide this level of security. The Telnet method of managing a switch does not
provide a secure connection.
SSH is a protocol that enables remote administrators to log securely into the switch over a network to
execute management commands.
SCP is used to copy files securely from one machine to another. SCP uses SSH for encryption of data on
the network. On a switch, SCP is used to download and upload the switch configuration via secure
channels.
XModem
The switch supports XModem for transferring files during direct dial-up communications. XModem sends
blocks of data in 128-byte blocks, and includes an error-detection system called a checksum. When the
data is received, the error detection system ensures that the entire message reached its destination. If not,
the receiving computer sends a request for retransmission of the data.
IGMP Snooping
The switch supports IGMP Snooping for multicasting. Both Version 1- and Version 2-based IGMP
Snooping are supported. In addition, auto detection of the multicast router port and manual configuration
of the multicast router port is supported. For efficient multicast traffic management, the IGMP Filtering
option is supported.
Jumbo frames
By default, the switch supports jumbo frames up to 9216 bytes, which help reduce server CPU utilization
and increase application throughput. No configuration is required. The switch does not fragment frames
as they exit, or assemble packets into jumbo frames as they enter the switch.
Auto-MDI/MDIX
The switch Ethernet ports are MDI/MDI crossover capable. MDI/MDIX is a type of Ethernet port
connection using twisted pair cabling. The MDI is the component of the MAU that provides the physical
and electrical connection to the cabling medium. An MDIX is a version of MDI that enables connection
between like devices. MDI ports connect to MDIX ports via straight-through twisted pair cabling whereas
both MDI-to-MDI and MDIX-to-MDIX connections use crossover twisted pair cabling. The switch has the
capability to automatically detect the cable selection/type, making the distinction between a straight-
through cable and a crossover cable unimportant.
Auto-negotiation of duplex mode and speed
Auto-negotiation of duplex mode and speed are configured on the switch. Network adapters that support
multiple data speeds, such as Fast Ethernet and Gigabit Ethernet, choose the speed at which they run
Introduction 13
Download from Www.Somanuals.com. All Manuals Search And Download.
through a procedure called auto-negotiation. Auto-negotiation involves probing the capability of the
network using low-level signaling techniques to select compatible Ethernet speeds. Auto-negotiation was
originally developed to make the migration from traditional Ethernet to Fast Ethernet products easier.
Redundant images in firmware
The switch stores up to two different software images, called image1 and image2, as well as boot
software, called boot. When downloading new software, the ability to specify where it is to be placed
(into image1, image2, or boot) is activated.
For example, if the active image is currently loaded into image1, load the new image software into
image2. This allows a test of the new software and the option to revert back to the original image stored
in image1, if needed.
CAUTION: Unlike the firmware that has two images, there is only one image of boot supported.
Upgrading the boot image replaces the original boot image.
External components
This section describes the rear panel of the switch.
Rear panel
Item
Description
Description
1
Reset button
Forces the switch to power up or
reboot
2
Health LED
•
•
Off—Not powered up
Green—Powered up and all
ports match
•
Amber—Indicates a problem
such as a port mismatch. For
more information, see the HP
BladeSystem enclosure setup and
installation guide.
3
UID LED
Introduction 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Description
4
DB-9 management serial
port
5
RJ-45 ports 20 - 24
CAUTION: Pressing the Reset button while the Health LED is green resets the switch.
Connectors
Item
Description
1
2
3
4
5
Port 20 RJ-45 connector for Gigabit Ethernet uplink
Port 21 RJ-45 connector for Gigabit Ethernet uplink
Port 22 RJ-45 connector for Gigabit Ethernet uplink
Port 23 RJ-45 connector for Gigabit Ethernet uplink
Port 24 RJ-45 connector for Gigabit Ethernet uplink
Introduction 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the switch
In this section
Planning the switch configuration............................................................................................................. 16
Installing the switch ................................................................................................................................ 18
Accessing the switch............................................................................................................................... 19
Logging on and configuring the switch...................................................................................................... 20
Cabling the switch.................................................................................................................................. 21
Supporting software and special considerations......................................................................................... 21
Planning the switch configuration
Before configuring the switch, HP recommends planning the configuration. Consider the default settings,
security issues and privileges, and whether to configure each switch manually or configure multiple
switches at the same time.
Default settings
The switch ships with a default configuration in which all downlink and uplink ports are enabled and
assigned a default VLAN with a VID equal to 1. This default configuration simplifies the initial setup by
allowing use of a single uplink cable (from any external Ethernet connector) to connect the server blade
enclosure to the network. By default, the X-connect ports (17 and 18) are disabled. Assess the particular
server environment to determine any requirements for other considerations.
The switch does not affect or determine NIC numeration and the associated mapping of NIC interfaces to
switch ports. The numbering of the NICs on the server (for example, NIC 1, NIC 2, NIC 3) is determined
by the server type, the server operating system, and what NICs are enabled on the server.
The Onboard Administrator module controls all port enabling. Enabling is based on matching ports
between the server and the interconnect bay. Before power up, the Onboard Administrator module
verifies that the server NIC option matches the switch bay that is selected and enables all ports for the
NICs installed.
NOTE: Port 19 is reserved for connection to the Onboard Administrator module for switch management.
This allows a user to enable the functionality of future firmware upgrade releases.
For detailed port mapping information, see the HP BladeSystem enclosure installation poster or the HP
BladeSystem enclosure setup and installation guide on the HP website
When planning the configuration, consider the default settings for these parameters:
•
•
•
•
•
•
Switch IP settings
VLAN settings
STP settings
Port names and types
Port trunking settings
Interswitch X-Connect port settings
Installing the switch 16
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
•
SNMP settings
User name and password settings
Default access to various management interfaces
NTP settings
IMPORTANT: See "Runtime switching software default settings (on page 28)" for a complete list of default
configuration settings.
Switch security
When planning the switch configuration, secure access to the management interface by:
•
•
•
Creating users with various access levels
Enabling or disabling access to various management interfaces to fit the security policy
Changing default SNMP community strings for read-only and read-write access
User, operator, and administrator access rights
To enable better switch management and user accountability, three levels or classes of user access have
been implemented on the switch. Levels of access to CLI, Web management functions, and screens
increase as needed to perform various switch management tasks. Conceptually, access classes are
defined as:
•
User interaction with the switch is completely passive. Nothing can be changed on the switch. Users
can display information that has no security or privacy implications, such as switch statistics and
current operational state information.
•
Operators can only effect temporary changes on the switch. These changes will be lost when the
switch is rebooted/reset. Operators have access to the switch management features used for daily
switch operations. Because any changes an operator makes are undone by a reset of the switch,
operators cannot severely impact switch operation.
•
Administrators are the only ones that can make permanent changes to the switch configuration,
changes that are persistent across a reboot/reset of the switch. Administrators can access switch
functions to configure and troubleshoot problems on the switch. Because administrators can also
make temporary (operator-level) changes as well, they must be aware of the interactions between
temporary and permanent changes.
Access to switch functions is controlled through the use of unique surnames and passwords. Once
connected to the switch via the local console, Telnet, or SSH, a password prompt appears.
NOTE: It is recommended to change the default switch passwords after initial configuration and as
regularly as required under the network security policies. For more information, see the HP GbE2c Ethernet
Blade Switch for c-Class BladeSystem Command Reference Guide.
The default user name and password for each access level are:
User account
Description and tasks performed
Password
User
The user has no direct responsibility for switch management. He or she user
can view all switch status information and statistics, but cannot make
any configuration changes to the switch.
Installing the switch 17
Download from Www.Somanuals.com. All Manuals Search And Download.
User account
Description and tasks performed
Password
Operator
The operator manages all functions of the switch. The operator can
reset ports or the entire switch.
By default, the operator account is disabled and has no password.
Administrator
The super user administrator has complete access to all menus,
information, and configuration commands on the switch, including the
ability to change both the user and administrator passwords.
admin
Manually configuring a switch
The switch is configured manually using a command line interface, a browser-based interface, or an
SNMP interface. See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference
Guide for more information on using these management interfaces to configure the switch.
After a switch is configured, back up the configuration as a text file to a TFTP server. The backup
configuration file is then downloaded from the TFTP server to restore the switch back to the original
configuration. This restoration is necessary if one of these conditions apply:
•
•
The switch configuration becomes corrupted during operation.
The switch must be replaced because of a hardware failure.
Configuring multiple switches
Configure multiple switches by using scripted CLI commands through Telnet or by downloading a
configuration file using a TFTP server.
Using scripted CLI commands through Telnet
The CLI, provided with the switch, executes customized configuration scripts on multiple switches. A
configuration script is tailored to one of the multiple switches, and then that configuration can be
deployed to other switches from a central deployment server.
Using a configuration file
If planning for the base configuration of multiple switches in a network to be the same, manually
configure one switch, upload the configuration to a TFTP server, and use that configuration as a base
configuration template file.
Switch IP addresses are acquired by default using BOOTP, therefore, each switch has a unique IP
address. Each switch is remotely accessed from a central deployment server and an individual switch
configuration is downloaded to meet specific network requirements. See the HP GbE2c Ethernet Blade
Switch for c-Class BladeSystem Command Reference Guide for additional information on using a TFTP
server to upload and download configuration files.
Installing the switch
Preparing for installation
IMPORTANT: Before installing the switch, make a record of the MAC address (printed on the MAC
address label attached to the switch). This address is needed when configuring the switch.
Installing the switch 18
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the switch
CAUTION: Do not cable the switch until after configuration.
IMPORTANT: Make sure that the server NIC configuration matches the switch bay selected.
NOTE: When installing two switches, there are two switch interconnect ports between adjacent I/O bays.
These ports (17 and 18) are disabled by default. The ports must be manually enabled to use.
To install the switch:
1. Remove the blank.
2. Install the switch.
Accessing the switch
The switch is accessed remotely using the Ethernet ports or locally using the DB-9 management serial port.
Installing the switch 19
Download from Www.Somanuals.com. All Manuals Search And Download.
To access the switch remotely:
1. Assign an IP address. By default, the switch is set up to obtain its IP address from a BOOTP server
existing on the attached network.
2. From the BOOTP server, use the switch MAC address to obtain the switch IP address.
3. From a computer connected to the same network, use the IP address to access the switch using a
Web browser or telnet application, which enables access to the switch BBI or CLI. The switch logon
prompt appears.
NOTE: If the switch does not obtain the IP address by means of the BOOTP service, access the switch
locally and configure the IP address manually. After assigning the IP address to the switch, then access the
switch remotely.
To access the switch locally:
1. Connect the switch DB-9 serial connector, using the null-modem serial cable to a local client device
(such as a laptop computer) with VT100 terminal emulation software.
2. Open a VT100 terminal emulation session with these settings: 9600 baud rate, eight data bits, no
parity, one stop bit, and no flow control.
Logging on and configuring the switch
To log on to the switch:
1. Connect to the switch console. After connecting, the login prompt displays as shown below.
2. Enter admin as the default administrator password.
The Main Menu displays with administrator privileges:
See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide for
information on configuring the IP address, changing configuration settings, and monitoring switch
operation using one of these interfaces:
•
•
Local RS-232 serial console management interface
Remote Telnet console management interface
See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based Interface Reference
Guide for information on using the embedded HTML interface to manage the switch from anywhere on
the network using a standard browser, such as Netscape Navigator or Microsoft Internet Explorer.
Installing the switch 20
Download from Www.Somanuals.com. All Manuals Search And Download.
describes how to use the MIBs to configure and monitor the switch using a generic SNMP manager, such
as HP OpenView Network Node Manager or HP Systems Insight Manager.
Cabling the switch
CAUTION: Do not cable the switch until after configuration.
To connect the switch to the network:
1. Connect the network cables to the switch.
2. Gather the network cables for the right side of the rack.
3. Insert the end of the cable-retaining bracket (provided with the bus bar and power bus boxes) into
the cable bracket (1).
4. Tighten the thumbscrew to secure the cable retaining bracket over the cables (2).
Supporting software and special considerations
Supporting software is available to assist in configuring and managing the switch.
•
Server Blade and Power Management Module Firmware—Provides firmware and installation
instructions required for proper rack location operation.
•
•
Utilities package and documentation—Provides utilities and documentation for switch management.
Firmware Upgrade Smart Component (for Microsoft Windows only)—Provides quick and easy
installation of the switch firmware, firmware upgrade tool, and readmefile. A SoftPaq is available
for use with Linux operating systems.
The utilities package and documentation, and the SoftPaq listed above, are available on the HP website
Installing the switch 21
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing and upgrading the switch
In this section
Replacing an existing switch.................................................................................................................... 22
Replacing an existing switch
CAUTION: Removing the switch from a powered enclosure results in the loss of network communications
between the server blade network ports that are connected through this switch and the segment of network
infrastructure those ports need to communicate.
For continued blade server network communication and services availability before removing the switch, redirect
critical high-availability services or applications to use the redundant network ports available on those blade
servers that are connected through the redundant switch in the enclosure.
CAUTION: Do not cable the switch until after configuration.
To replace an existing switch:
1. Save the configuration file to a TFTP server for later retrieval. For more information on saving a
configuration file to a TFTP server, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem
Command Reference Guide.
2. Remove the switch.
3. Slide the new switch fully into the interconnect bay. For more installation information, see "Installing
4. Close the ejector lever and let the switch boot up completely, so that network connectivity is
established.
Replacing and upgrading the switch 22
Download from Www.Somanuals.com. All Manuals Search And Download.
5. If the configuration file was saved to a TFTP server, download the configuration. For more
information on downloading a configuration file, see the HP GbE2c Ethernet Blade Switch for c-
Class BladeSystem Command Reference Guide.
Replacing and upgrading the switch 23
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory compliance notices
In this section
Class A equipment ................................................................................................................................. 24
Modifications......................................................................................................................................... 24
Cables.................................................................................................................................................. 24
Canadian notice .................................................................................................................................... 24
European Union regulatory notice ............................................................................................................ 25
BSMI notice........................................................................................................................................... 25
Japanese class A notice .......................................................................................................................... 25
Korean class A notice............................................................................................................................. 26
Laser compliance ................................................................................................................................... 26
Class A equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case the user will be required to correct
the interference at personal expense.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are
not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the
equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in
order to maintain compliance with FCC Rules and Regulations.
Canadian notice
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Regulatory compliance notices 24
Download from Www.Somanuals.com. All Manuals Search And Download.
European Union regulatory notice
This product complies with the following EU Directives:
•
•
Low Voltage Directive 73/23/EEC
EMC Directive 89/336/EEC
Compliance with these directives implies conformity to applicable harmonized European standards
(European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this
product or product family.
This compliance is indicated by the following conformity marking placed on the product:
This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth).
This marking is valid for EU non-harmonized Telecom products.
*Notified body number (used only if applicable—refer to the product label)
BSMI notice
Japanese class A notice
Regulatory compliance notices 25
Download from Www.Somanuals.com. All Manuals Search And Download.
Korean class A notice
Laser compliance
This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic
transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in
accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser
radiation.
Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser
Notice No. 50, dated May 27, 2001; and with IEC 60825-1:1993/A2:2001.
WARNING: Use of controls or adjustments or performance of procedures other than
those specified herein or in the laser product's installation guide may result in hazardous
radiation exposure. To reduce the risk of exposure to hazardous radiation:
•
•
•
Do not try to open the module enclosure. There are no user-serviceable components
inside.
Do not operate controls, make adjustments, or perform procedures to the laser device
other than those specified herein.
Allow only HP Authorized Service technicians to repair the unit.
The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration
implemented regulations for laser products on August 2, 1976. These regulations apply to laser products
manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.
Regulatory compliance notices 26
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical specifications
In this section
General specifications ............................................................................................................................ 27
Runtime switching software default settings................................................................................................ 28
Physical and environmental specifications ................................................................................................. 35
Performance specifications ...................................................................................................................... 35
General specifications
Category
Specification
Standards:
IEEE 802.3 10Base-T Ethernet
IEEE 802.3u 100Base-TX Fast Ethernet
IEEE 802.3ab 1000Base-T Ethernet
IEEE 802.3z 1000Base-SX Ethernet
IEEE 802.1D Spanning Tree Protocol
IEEE 802.1s Multiple Spanning Tree Protocol
IEEE 802.1w Rapid Spanning Tree Protocol
IEEE 802.1Q VLAN
IEEE 802.3ac Frame Extensions for VLAN
IEEE 802.3ad Link Aggregation Protocol (No LACP support)
IEEE 802.3x Full-Duplex Flow Control
ANSI/IEEE 802.3 Nway Auto-Negotiation
CSMA/CD
Protocols:
Data transfer rates:
Ethernet
Half-Duplex: 10 Mb/s
Full-Duplex: 20 Mb/s
Half-Duplex: 100 Mb/s
Full-Duplex: 200 Mb/s
Half-Duplex: 2000 Mb/s
Full-Duplex: 2000 Mb/s
Fast Ethernet
Gigabit Ethernet
Connectors:
HP GbE2c switch
10Base-T
5 RJ-45, 1 DB-9
Two Pair UTP Category 3, 4, 5 (100 m)
EIA/TIA-568 100-ohm STP (100 m)
Two Pair or Four Pair UTP Category 5 (100 m)
EIA/TIA-568 100-ohm STP (100 m)
Four Pair UTP Category 5e (100 m)
EIA/TIA-568 100-ohm STP (100 m)
100Base-TX
1000Base-T
Technical specifications 27
Download from Www.Somanuals.com. All Manuals Search And Download.
Category
Specification
Number of ports per
switch:
16 x 1000-Mb/s ports dedicated to server blade for switch communications
2 x 1000-Mb/s ports dedicated to communications between switches that are
inserted in 1 and 2, 3 and 4, 5 and 6, or 7 and 8
5 x 10Base-T/100Base-TX/1000Base-T RJ-45 ports
1 x serial RS-232 DB-9 rear panel management serial port
Runtime switching software default settings
General default settings
Setting
Value
Notice
Banner
None
None
User names and
passwords
User names and passwords:
•
•
•
user—Enabled, password is user
oper—Disabled, no password
admin—Enabled (cannot be disabled), password is admin
BOOTP service
Enabled
0.0.0.0
IP address (if manual IP
option is selected)
Subnet mask (if manual IP 0.0.0.0
option is selected)
Primary default gateway
0.0.0.0
0.0.0.0
Secondary default
gateway
Primary DNS server
address
0.0.0.0
0.0.0.0
Secondary DNS server
address
Default domain name
None
Management
network/mask
0.0.0.0 / 0.0.0.0
Switch software image on Image 1
next boot
Switch Config file on next Active
boot
Display Hostname
(sysName) in CLI prompt
Disabled
Idle timeout
Telnet status
Telnet port
Web status
Web port
5 minutes
Enabled
23
Enabled
80
Technical specifications 28
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
Backpressure
Port state
Disabled
Enabled
Port speed/duplex
Flow control
STP
Auto
Receive & transmit
STG 1—Enabled with default VLAN (VID=1)
Port 1-16 (server ports) STP—Disabled at port level
STG 2-16—Disabled
20 seconds
2 seconds
Bridge Max Age
Bridge Hello Time
Bridge Forward Delay
Bridge Priority
15 seconds
32768
MAC Address Aging Time 300 seconds
Port Priority
Path Cost
128
4
Static VLAN Entry
Port VID
Default VLAN (VID = 1)
1 for all ports
Port Trunking
Trunk group 1, enabled with port 17 and 18
Port Trunking Load Sharing The algorithm selects the following as forwarding ports for forwarding traffic:
Algorithm
1
2
3
For forwarding IP Packets—modulus of XOR of last 3 bits of source and last 3
bits of Destination IP address
For forwarding non-IP packets—modulus of XOR of last 3 bits of source and
last 3 bits of Destination MAC address
For forwarding broadcast, multicast packets, and unknown unicast packets—
the lowest active port number in the trunk group
Port Mirroring-Mirror Status Disabled
Port Mirroring-Mirror Port
None selected
None selected
Port Mirroring-Mirror Port
Traffic Direction
Port Mirroring-Monitoring None selected
Port
SNMP
Read/write
None
SNMP System Name
SNMP System Location
SNMP System Contact
None
None
SNMP Community
String/Access Right
Public—read-only
Private—read/write
0.0.0.0
SNMP Trap Host 1
SNMP Trap Host 1
Community String
Public
SNMP Trap Host 2
0.0.0.0
Public
SNMP Trap Host 2
Community String
Technical specifications 29
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
SNMP Authentication
Traps
Disabled
SNMP Link Up/Down
Traps
Enabled
Security IP Network/Mask 0.0.0.0 / 0.0.0.0
TFTP Server IP Address
TFTP Port Number
0.0.0.0
69
Firmware upgrade
File name—none
File name—none
Configuration file from
TFTP server
Configuration file to TFTP
server
File name—none
PING tool
Target address—undefined
Default tries—5
Trace Route tools
Serial Port Baud Rate
Serial Port Data Bit
Serial Port Parity Bit
Serial Port Stop Bit
Serial Port Flow Control
Default VLAN
Target address—undefined
9600
8
None
1
None
Default VLAN (VID=1) with all ports assigned including CPU, STG=1
NTP State
Disabled
0.0.0.0
NTP Server
NTP Resync Interval
GMT Timezone Offset
720 minutes
-06:00
Daylight Savings Time
State
Disabled
System Up Time
Current time
0 days 00 :00 :00
RTC or NTP (00 :00 :00)
Date
None
0.0.0.0
0.0.0.0
7
Syslog Host
Syslog Host 2
Syslog Host Severity
Syslog Host 2 Severity
Syslog Console Output
7
Disabled
Technical specifications 30
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
Log
•
•
•
•
•
•
•
•
•
•
0
console—Enabled
system—Enabled
mgmt—Enabled
cli—Enabled
stp—Enabled
vlan—Enabled
ssh—Enabled
ntp—Enabled
ip—Enabled
web—Enabled
RSA Server Key Autogen
Interval
RSA Server Key Autogen
SSH Server
Disabled
On
SCP-only Administrator
Password
admin
SSH Server Port
22
SCP Apply and Save
RADIUS Server
Disabled
Off
RADIUS Secret
None
0.0.0.0
Primary RADIUS Server
Secondary RADIUS Server 0.0.0.0
RADIUS Server Port
1645
RADIUS Server Retries
RADIUS Server Timeout
3
3
RADIUS Backdoor for
Telnet Access
Disabled
Re-ARP Period in Minutes
MSTP
10
Disabled
RSTP
MSTP Default Mode
MSTP Region Name
MSTP Region Version
MSTP Max Hop Count
CIST Bridge Max Age
CIST Bridge Hello Time
None
1
20
20 seconds
2 seconds
15 seconds
CIST Bridge Forward
Delay
CIST Bridge Priority
32768
CIST MAC Address Aging 300 seconds
Time
CIST Port Priority
CIST Port Path Cost
MSTP Link Type
128
20000
Auto
Technical specifications 31
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
MSTP Edge Port
Enabled: ports 1-16
Off
TACACS+ Service
TACACS+ Primary Secret None
TACACS+ Secondary
Secret
None
Primary TACACS+ Server 0.0.0.0
Secondary TACACS+
Server
0.0.0.0
TACACS+ Server Port
49
TACACS+ Server Retries
3
TACACS+ Server Timeout 5 seconds
TACACS+ Backdoor for
Telnet Access
Disabled
IGMP Snooping
IGMP VLANs
Disabled
None
IGMP Report Timeout
10 seconds
255 seconds
IGMP Multicast Router
Timeout
IGMP Robust
2
Aggregate IGMP Report
IGMP Fastleave
IGMP Fastleave VLANs
IGMP Filtering
Disabled
Disabled
None
Disabled
None
IGMP Filters
Static Multicast Router Port None
Uplink Failure Detection
(UFD)
Off
UFD Failure Detection Pair Disabled
UFD Link To Monitor - Port None
UFD Link To Monitor -
Trunk
None
UFD Link to Disable - Ports None
UFD Link To Disable -
Trunks
None
None
None
RMON History Group
Number
RMON History Interface
MIB to Monitor
RMON History Number of 30
Requested Buckets
RMON History Polling
Interval
1800
RMON History Owner
None
Technical specifications 32
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
RMON Event Group
Number
None
RMON Event Description
RMON Event Type
None
None
None
RMON Alarm Group
Number
RMON Alarm MIB to
Monitor
None
RMON Alarm Interval
1800
abs
RMON Alarm Sample
Type
RMON Alarm Type
either
0
RMON Alarm Rising
Threshold
RMON Alarm Falling
Threshold
0
0
RMON Alarm Rising Event
Index
RMON Alarm Falling Event 0
Index
RMON Alarm Owner
IP Forwarding
Null
Disabled
Configurable User Name - admin
admpw
Configurable User Name - Disabled
opw
Configurable User Name - user
usrpw
Configurable User Name - Disabled
UID 1-10
Uplink Fast
Disabled
THASH - enable
SIP and DIP
SNMPv1 - Read community public
string:
SNMPv1 - Write
community string:
private
SNMPv1 - SNMP state
machine timeout:
5
SNMPv1 - authentication
traps:
Disabled
Disabled
Enabled
SNMPv1 - Uplink Failure
Detection traps:
SNMPv1 - link up/down
traps:
SNMPv1 - v1/v2 access:
IGMP
Enabled
off
Technical specifications 33
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting
Value
MCAST/BCAST/UCAST
SNMPv3 - SNMP access
SNMPv3 - v1v2 access
SNMPv3 - adminmd5
SNMPv3 - adminsha
SNMPv3 - v1v2only
off
read/write enabled
Enabled
authentication = md5, privacy = des
authentication = sha, privacy = des
authentication = none, privacy = none
level=authPriv,
SNMPv3 - admingrp
users=adminmd5,
adminsha, rview, wview, nview=iso
level=noAuthNoPriv,
users=v1v2only,
SNMPv3 - v1v2grp
rview, wview=iso,
nview=v1v2only
SNMPv3 - iso
subtree = 1, included
subtree=1, included
SNMPv3 - v1v2only
subtree=1.3.6.1.6.3.15, excluded
subtree=1.3.6.1.6.3.16, excluded
subtree=1.3.6.1.6.3.18, excluded
21 (not configurable)
Enabled, (not configurable)
Disabled
FTP - port
Browser upgrade option
STP Fast
HTTPS Port
Disabled
Port names, VLANs, STP, trunking default settings
These default settings apply to all ports:
•
•
•
•
Speed—Autonegotiate
PVID—1
Tag (Y/N)—N
VLAN Name—Default VLAN
Port type
Server
Port number
Port name
Downlink1
Downlink2
Downlink3
Downlink4
Downlink5
Downlink6
Downlink7
Downlink8
Downlink9
Downlink10
STP
Trunk group
1
2
3
4
5
6
7
8
9
10
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Server
Server
Server
Server
Server
Server
Server
Server
Server
Technical specifications 34
Download from Www.Somanuals.com. All Manuals Search And Download.
Port type
Server
Port number
Port name
STP
Trunk group
11
12
13
14
15
16
17
18
19
Downlink11
Downlink12
Downlink13
Downlink14
Downlink15
Downlink16
XConnect1
XConnect1
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Enabled
Server
Server
Server
Server
Server
X-Connect
X-Connect
1
1
Reserved for future
use
Uplink
Uplink
Uplink
Uplink
Uplink
20
21
22
23
24
Uplink1
Uplink2
Uplink3
Uplink4
Uplink5
Enabled
Enabled
Enabled
Enabled
Enabled
Physical and environmental specifications
Category
Specification
DC inputs
12VDC: 2.0A maximum per switch
25 W maximum per switch
Power
consumption
Operating
10° to 40° C (50° to 104° F)
-40° to 70° C (-40° to 158° F)
5% to 95% RH noncondensing
5% to 95% RH noncondensing
temperature
Storage
temperature
Operating
humidity
Storage humidity
Switch dimensions 267.7 x 192.79 x 27.94 mm (10.5 x 7.5 x 1.1 in.)
Weight
Safety
1.8 Kg (3.97 lbs.)
•
TUV to UL 60950-1, and CAN/CSA C22.2 No.
60950-1 and to EN 60950-1
•
•
CE Marking
RoHS 5/6 compliant
Performance specifications
Category
Specification
Transmission
method
Store-and-forward
Memory
128 MB main, 16 MB flash, and 1 MB shared packet
buffer memory per switch
Technical specifications 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Category
Specification
MAC address
table size
8 KB per switch
Packet forwarding 1,488,095 packets per second with 64 byte packets per
rate port (for 1000 Mb/s)
Maximum external 5 X 1 GB port = 5 X 1,488,095 = 7,440,475 pps per
port packet
switch
16 : 5
forwarding rate
Best downlink
external port
packet forwarding
rate ratio
Interswitch x-
connects across
enclosure
2 X 1 GB ports bundled in Port Trunk of 2 GB size
backplane
MAC address
learning
Automatic update
Forwarding table
age time
Maximum age: 1 to 1,000,000 seconds
Default: 300 seconds
Technical specifications 36
Download from Www.Somanuals.com. All Manuals Search And Download.
Performing a serial download
In this section
Introduction ........................................................................................................................................... 37
Serial upgrade of boot code firmware image procedure............................................................................. 37
Serial upgrade of operating system firmware procedure ............................................................................. 39
Introduction
Perform a serial download of the switch operating system firmware, or boot code firmware if upgrading a
switch directly from any existing OS or boot code images.
This procedure requires:
•
•
•
A computer running terminal emulation software
A standard null modem cable with a female DB-9 connector
A switch OS firmware and/or boot code images
Serial upgrade of boot code firmware image procedure
To perform a serial upgrade of the switch boot code firmware image, usually named
pGbE2c_b_100.bin:
1. Using the null modem, connect the console port of the switch to the serial port of a PC that supports
XModem/1K XModem.
2. Start HyperTerminal (part of Microsoft Windows) or equivalent terminal emulation application
(depending on the computer operating system), and set the parameters for the terminal emulation
console:
Parameter
Baud rate
Date bits
Parity
Value
9600
8
None
1
Stop bits
Flow control
None
3. Power on the switch.
Performing a serial download 37
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Hold down the Shift key and press the D key repeatedly during the Memory Test, until this message
appears:
NOTE: To perform serial downloads at 57600 baud rate, press the Shift-F keys. To perform serial
downloads at 115200 baud rate, press the Shift-D keys.
5. After the message in Step 4 appears, reconfigure the terminal emulation console using these
parameters.
Parameter
Baud rate
Data bits
Parity
Value
115200
8
None
1
Stop bits
Flow control
None
6. Press the Enter key several times on the PC that is connected to the console port of the switch. When
the console port is successfully communicating with the PC, indicating readiness for image transfer,
continuous C's appear:
7. Be sure that the new switch boot code firmware file is available on the computer. This file can be
downloaded from the CD that is shipped with the switch or from the HP website
8. Select <Transfer-Send File> from the menu and choose these options in the Send File window:
The Send File window displays progress of the file transfer. The file transfer might take up to seven
minutes.
NOTE: Although slower, XModem also works if 1K MODEM is not used.
9. After completing the transfer, a message displays how many bytes transferred, followed by another
message displaying the status of image extraction. Do not power cycle the switch during this
process. After extracting the image, it is updated to flash and a message with a progress indicator
displays as shown.
Performing a serial download 38
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTION: Do not power off the switch until the message: "Change your baud rate to 9600 bps and
power cycle the switch," is displayed, otherwise, the switch will be inoperable.
10. Change the baud rate to 9600 and power off the switch, wait for a few seconds, and power on the
switch.
The switch boots with the new version of the boot code image that was just downloaded.
Serial upgrade of operating system firmware procedure
To perform a serial upgrade of the switch operating system firmware image, usually named
pGbE2c_100.bin:
1. Using the null modem cable, connect the console port of the switch to the serial port of a PC that
supports XModem/1K XModem.
2. Start HyperTerminal (part of Microsoft Windows) or equivalent terminal emulation application
(depending on the computer operating system) and set the parameters for terminal emulation
console:
Parameter
Baud rate
Data bits
Parity
Value
9600
8
None
1
Stop bits
Flow control
None
3. Power on the switch.
4. Hold down the Shift key and press the D key repeatedly during the Memory Test, until this message
appears:
NOTE: To perform serial downloads at 57600 baud rate, press the Shift-F keys. To perform serial
downloads at 115200 baud rate, press the Shift-D keys.
Performing a serial download 39
Download from Www.Somanuals.com. All Manuals Search And Download.
5. After the message in Step 4 appears, reconfigure the terminal emulation console using these
parameters.
Parameter
Baud rate
Data bits
Parity
Value
115200
8
None
1
Stop bits
Flow control
None
6. Press the Enter key several times on the PC that is connected to the console port of the switch. When
the console port is successfully communicating with the PC, indicating readiness for image transfer,
continuous C's appear:
7. Be sure that the new switch operating system firmware file is available on the computer. This file can
be downloaded from the CD that is shipped with the switch or from the HP website
8. Select <Transfer-Send File> from the menu and choose these options in the Send File window:
The Send File window displays the progress of the file transfer. The file transfer might take up to five
minutes.
NOTE: Although slower, XModem also works if 1K MODEM is not used.
9. After completing the transfer, a message displays how many bytes transferred, followed by another
message displaying the status of image extraction. Do not power cycle the switch during this
process.
CAUTION: Do not power off the switch until the message: "Change your baud rate to 9600 bps and
power cycle the switch," is displayed, otherwise, the switch will be inoperable.
10. After extracting the image, the system prompts to select which current operating system image
(image1 or image2) needs to be updated by the new operating system image. It also provides an
option (n) not to update any and to quit the update procedure.
Performing a serial download 40
Download from Www.Somanuals.com. All Manuals Search And Download.
Depending on the selection, 1 or 2, the system updates image1 or image2 on the flash and a
message with a progress indicator displays as shown below. If selecting n, the system aborts the
update procedure and prompts to reset the baud rate and power cycle the switch.
-or-
-or-
11. Change the baud rate to 9600 and power off the switch. Wait for a few seconds, and power on the
switch.
During bootup the switch the following prompt appears:
To use the other operating system image, press the Ctrl-o keys.
Performing a serial download 41
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP MIBs support
In this section
MIB overview......................................................................................................................................... 42
SNMP Manager software........................................................................................................................ 42
Supported MIBs ..................................................................................................................................... 43
Supported traps ..................................................................................................................................... 43
MIB overview
Management and statistics information is stored in the switch in the MIB. The switch supports several
standard MIBs. Values for MIB objects are retrieved with any SNMP-based network management
software.
In addition to the standard MIBs, the switch also supports its own proprietary enterprise MIB as an
extended MIB. The proprietary MIB is retrieved by specifying the MIB OID at the network manager
station.
MIB values are either read-only or read/write variables.
•
Read-only MIB variables are constants that are programmed into the switch or variables that change
while the switch is in operation. Examples of read-only constants include the number and types of
ports. Examples of read-only variables are the statistics counters, such as the number of errors that
have occurred or how many kilobytes of data have been received and forwarded through a port.
•
Read/write MIB variables are usually related to user-customized configurations. Examples include
the IP address of the switch, Spanning Tree Algorithm parameters, and port status.
SNMP Manager software
Using third-party vendor SNMP software to manage the switch allows access to proprietary enterprise
MIBs for the switch. The MIBs are found in the utilities on the HP website
If the software provides functions to browse or modify MIBs, the MIB values (if the MIB attributes permit
the write operation) are changeable. This process can be quite involved, because the MIB OIDs (available
in the MIB files) must be used and retrieved one by one.
Use an SNMP manager, such as HP OpenView Network Node Manager or HP Systems Insight Manager,
to access the enterprise-specific MIBs. Compile the MIBs into the MIB database and then use a MIB
browser to navigate through them. For detailed information, access the individual descriptions of each
MIB or see the documentation that came with the SNMP manager software.
The switch SNMP agent supports SNMP Version 1. Security is provided through SNMP community strings.
The default community strings are "public" for SNMP GET operation and "private" for SNMP SET
operation.
Users can specify up to two trap hosts for receiving SNMP traps. The agent sends the SNMP trap to the
specified hosts when appropriate. Traps are not sent if there is no host specified.
SNMP MIBs support 42
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported MIBs
The SNMP agent for the switch supports these MIBs:
bt2Network.mib
bt2Physical.mib
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
bt2Switch.mib
bt2trap.mib
cpqhost.mib
cpqsinfo.mib
cpqrack.mib
hpswitchpl.mib
rfc1213.mib
rfc1493.mib
rfc1573.mib
rfc1643.mib
rfc1757.mib
rfc1907.mib
rfc2037.mib
rfc2571.mib
rfc2572.mib
rfc2573.mib
rfc2574.mib
rfc2575.mib
rfc2576.mib
Supported traps
The switch SNMP agent supports these traps:
bt2trap.mib traps
bt2SwDefGwUp
bt2SwDefGwDown
•
•
•
•
•
•
•
•
•
•
•
•
•
•
bt2SwDefGwInService
bt2SwDefGwNotInService
bt2SwLoginFailure
bt2SwTempExceedThreshold
bt2SwApplyComplete
bt2SwSaveComplete
bt2SwFwDownloadSucess
bt2SwFwDownloadFailure
bt2SwTempReturnThreshold
bt2SwUfdfoLtMFailure
bt2SwUfdfoLtMUP
SNMP MIBs support 43
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
•
bt2SwUfdfoGlobalEna
bt2SwUfdfoGlobalDis
bt2SwUfdfoLtDAutoEna
bt2SwUfdfoLtDAutoDis
•
rfc1215.mib traps
•
•
•
•
•
•
coldStart
warmStart
linkDown
linkUp
authenticationFailure
egpNeighborLoss
•
•
rfc1493.mib traps
•
•
newRoot
topologyChange
rfc1757.mib traps
•
•
risingAlarm
fallingAlarm
SNMP MIBs support 44
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrostatic discharge
In this section
Preventing electrostatic discharge............................................................................................................. 45
Grounding methods to prevent electrostatic discharge ................................................................................ 45
Preventing electrostatic discharge
To prevent damaging the system, be aware of the precautions you need to follow when setting up the
system or handling parts. A discharge of static electricity from a finger or other conductor may damage
system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the
device.
To prevent electrostatic damage:
•
•
•
•
•
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or assembly.
Grounding methods to prevent electrostatic discharge
Several methods are used for grounding. Use one or more of the following methods when handling or
installing electrostatic-sensitive parts:
•
Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist
straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords.
To provide proper ground, wear the strap snug against the skin.
•
Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet
when standing on conductive floors or dissipating floor mats.
•
•
Use conductive field service tools.
Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an authorized reseller
install the part.
For more information on static electricity or assistance with product installation, contact an authorized
reseller.
Electrostatic discharge 45
Download from Www.Somanuals.com. All Manuals Search And Download.
RJ-45 pin specification
In this section
Standard RJ-45 receptacle/connector....................................................................................................... 46
Standard RJ-45 receptacle/connector
When connecting the switch to a switch, bridge, or hub, an Ethernet cable is necessary.
The table indicates the pin number and wire color assignments for the switch-to-network adapter card
connection, and the Ethernet cable for the switch-to-switch, switch-to-hub, or switch-to-bridge connection.
Contact
Media direct interface signal
Tx + (transmit)
Tx - (transmit)
Rx + (receive)
Not used
Color match
1
2
3
4
5
6
7
8
White/Orange
Orange/White
White/Green
Blue/White
Not used
White/Blue
Rx - (receive)
Not used
Green/White
White/Brown
Brown/White
Not used
The table provides the same information for the Gigabit over Copper ports.
Contact
Media direct interface signal
Color match
1
2
3
4
5
6
7
8
BI_DA+
BI_DA-
BI_DB+
BI_DC+
BI_DC-
BI_DB-
White/Orange
Orange/White
White/Green
Blue/White
White/Blue
Green/White
White/Brown
Brown/White
BI_DD+
BI_DD-
RJ-45 pin specification 46
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
In this section
Forgotten administrator user name and password that was configured on the switch...................................... 47
Health LED on the switch is not on............................................................................................................ 47
Health LED on the switch stays amber for more than 30 seconds and switch does not boot............................. 48
No link LED appears, even after plugging the Category 5 cable in the RJ-45 connector of the external port...... 48
Program................................................................................................................................................ 48
The switch fails to get its IP settings from the BOOTP server, even though by default it is configured for BOOTP 49
The keyboard locks up when using HyperTerminal to log on to the switch through the console interface........... 49
Cannot connect to the switch console interface remotely using Telnet............................................................ 49
Password is not accepted by the switch using the remote console interface immediately after a reboot............. 49
Cannot connect to the switch SNMP interface............................................................................................ 50
destination device .................................................................................................................................. 50
Cannot connect to the switch remotely using the Web interface................................................................... 50
VLANs .................................................................................................................................................. 51
download fails....................................................................................................................................... 51
connection the download or upload fails................................................................................................... 51
transfer after forcing the switch into the download mode, and does not display CCCC... ............................... 52
The download fails after starting to download the firmware file ................................................................... 52
The switch configuration is corrupt ........................................................................................................... 52
Forgotten administrator user name and password that was
configured on the switch
Action:
Call HP technical support at 1-800-652-6672, or call a service representative to get a backdoor
password.
Health LED on the switch is not on
Action:
•
The switch is not seated properly. Be sure that the switch is inserted completely and seated properly.
Troubleshooting 47
Download from Www.Somanuals.com. All Manuals Search And Download.
•
The server blade enclosure is not powered up. Be sure that the server blade enclosure is powered up
and all the power connections are intact.
•
•
There is a faulty LED. Check the console to see if the switch is booted.
The switch fuse is blown. Send for repair.
Health LED on the switch stays amber for more than 30
seconds and switch does not boot
Action:
The Standby Mode Timeout function is malfunctioning. Force the switch to reboot by pressing the Reset
button.
No link LED appears, even after plugging the Category 5
cable in the RJ-45 connector of the external port
Action:
•
The cable is not properly plugged in. Check the cable at both ends to ensure that it is plugged in
and seated properly.
•
•
The cable or connector heads are faulty. Replace the cable with another tested cable.
The RJ-45 connector on the switch or LED is faulty.
•
After checking and replacing the cable, if no link LED displays, check whether the port is
transferring data. If yes, the LED is faulty. If no, it could be a faulty RJ-45 connector. Call a
service representative.
•
This could be caused by using a crossover cable instead of a straight through cable.
Cannot access the switch serial console interface using
null modem connection from a PC Terminal Emulation
Program
Action:
•
The null modem cable is faulty. Be sure the null modem cable, provided by HP with this hardware,
was used.
•
The connection settings do not match the switch serial settings. Be sure that the PC Terminal
Emulation session settings match the switch serial settings.
Error message that the switch failed to complete the system
self-testing appears on the serial console screen
Action:
The system diagnostic tests failed. Note the reason for the failure from the serial console screen message
and call a service representative.
Troubleshooting 48
Download from Www.Somanuals.com. All Manuals Search And Download.
The switch fails to get its IP settings from the BOOTP
server, even though by default it is configured for BOOTP
Action:
•
The switch is not connected properly to the network. Check the cable and connections and be sure
that there is network connectivity between the switch and the BOOTP server.
•
The BOOTP server is not available on the network or VLAN that is attached to the switch
management port. Be sure that the BOOTP server is present on the network or VLAN attached to the
switch.
•
•
The BOOTP server cannot offer IP settings to the switch because no IP addresses are available. Add
additional IP addresses as necessary.
The switch timed out its request for IP settings. Reset the switch.
The keyboard locks up when using HyperTerminal to log
on to the switch through the console interface
Action:
Scroll lock is on. Press the Scroll Lock key on the keyboard and be sure that the scroll lock is off.
Cannot connect to the switch console interface remotely
using Telnet
Action:
•
The switch IP address is not configured or correct.
•
From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
•
Use the correct IP address to establish the Telnet connection with the switch.
•
•
The setting allowing access to the switch using the Telnet interface is disabled. From the serial
console interface, be sure that the Telnet interface is enabled.
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the Management Network
Address/Mask contains the IP address of the management station.
Password is not accepted by the switch using the remote
console interface immediately after a reboot
Action:
The switch is still working on network convergence. Wait up to 10 seconds for the password to be
accepted.
Cannot connect to the switch console interface remotely
using SSH
Action:
Troubleshooting 49
Download from Www.Somanuals.com. All Manuals Search And Download.
•
The switch IP address is not configured or correct.
•
From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
•
Use the correct IP address to establish the SSH connection with the switch.
•
•
The setting allowing access to the switch using the SSH interface is disabled.
From the serial console interface, be sure that the SSH interface is enabled and all the settings are
configured correctly.
•
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.
Cannot connect to the switch SNMP interface
Action:
•
The switch IP address is not configured or correct.
•
From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
•
Use the correct IP address to establish the SNMP connection with the switch.
•
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.
The port activity LEDs continuously indicate activity after
connecting more than one port to another switch or
destination device
Action:
Because there are multiple links across this device and the destination device, they form loops, which
cause broadcast storms. Enable STP for multiple links. This setting prevents loops and maintains standby
links for resilience in case of primary link failure.
Cannot connect to the switch remotely using the Web
interface
Action:
•
The switch IP address is not configured or correct.
•
From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
•
Use the correct IP address to establish the Web connection with the switch.
•
•
Access to the switch using the Web interface is disabled. From the serial console interface, be sure
that the Web interface is enabled.
The Proxy server settings are configured on the Internet browser and the proxy server does not know
the switch IP address. Disable the manual proxy settings on the Web browser and let it automatically
find Web servers using the IP address.
Troubleshooting 50
Download from Www.Somanuals.com. All Manuals Search And Download.
•
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.
Cannot enable a port in multiple VLANs while configuring
VLANS
Action:
A port is part of only one VLAN unless the port is a tagged port. Be sure that the port is enabled as a
tagged port.
The switch does not let the user enable two adjacent ports
into two different VLANs while assigning the ports to
VLANs
Action:
The ports are two adjacent ports that are bundled in a Port Trunk. Two ports that are assigned to a Port
Trunk cannot be assigned to two different VLANs. Either break the trunk to assign it two different VLANs
or assign the ports to one VLAN.
While using TFTP to download firmware, the switch fails to
connect to the TFTP server, or after connection the
download fails
Action:
•
The TFTP server is not available to connect to or there is connectivity failure between the switch and
TFTP server.
•
•
•
Be sure that the IP address of the TFTP server is correct.
Be sure that the TFTP server exists on the same network and VLAN as the switch.
Be sure that the TFTP server can be pinged from the switch and vice versa.
•
•
The firmware file is not found on the TFTP server. The file name could be wrong.
•
•
Be sure that a valid firmware file exists on the TFTP server to download to the switch.
On the switch, check the file name configured to download.
The TFTP server was started with a configured directory. The switch must be configured using the full
path name, if it is not in the directory specified in the TFTP server.
The switch fails to connect to the TFTP server while using
TFTP to download or upload a configuration file, or after
connection the download or upload fails
Action:
•
The TFTP server is not available to connect or there is a connectivity failure between the switch and
the TFTP server.
Troubleshooting 51
Download from Www.Somanuals.com. All Manuals Search And Download.
•
•
•
Be sure that the TFTP server exists on the same network or VLAN as that of the switch.
Be sure that the TFTP server can be pinged from the switch and vice versa.
Be sure that the IP address of the TFTP server is correct.
•
•
The configuration file is not found on the TFTP server. The file name could be wrong.
•
•
Be sure that a valid configuration file exists on the TFTP server to download to the switch.
On the switch, check the file name configured to download or upload.
The TFTP server was started with a configured directory. The switch must be configured using the full
path name, if it is not in the directory specified in the TFTP server.
The console screen displays a message to change the
baud rate for the terminal emulation session for XModem
transfer after forcing the switch into the download mode,
and does not display CCCC...
Action:
The terminal emulation session baud rate does not match the switch serial console baud rate in the
download mode. Change the baud rate of the terminal emulation session to match the switch serial
console baud rate in the download mode.
IMPORTANT: The baud rate for the switch serial console in the download mode and runtime mode are
two separate settings.
The download fails after starting to download the
firmware file
Action:
The firmware file is not the correct one or is corrupt. Obtain the latest firmware file that is specified for this
switch.
The switch configuration is corrupt
Action:
An error was made when saving the switch configuration. Reboot the switch and reload the factory
settings. This action clears all settings and restores them to the initial values that were present when the
switch was purchased. See the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command
Reference Guide for more information.
After reloading the factory settings, reconfigure the switch settings.
Troubleshooting 52
Download from Www.Somanuals.com. All Manuals Search And Download.
Acronyms and abbreviations
AAA
authentication, authorization, and accounting
BBI
browser-based interface
BOOTP
Bootstrap Protocol
CLI
Command Line Interface
CPU
central processing unit
CSMA/CD
Carrier Sense Multiple Access with Collision Detection
DNS
domain name system
FDB
forwarding database
FTP
file transfer protocol
GMT
Greenwich mean time
IEEE
Institute of Electrical and Electronics Engineers
IGMP
Internet Group Management Protocol
Acronyms and abbreviations 53
Download from Www.Somanuals.com. All Manuals Search And Download.
IP
Internet Protocol
LAN
local-area network
MAC
medium access control
MAU
media attachment unit
MDI
medium dependent interface
MDI-X
medium dependent interface-crossover
MIB
management information base
MSTP
Multiple Spanning Tree Protocol
NAS
network access server
NIC
network interface controller
NTP
network time protocol
NVRAM
non-volatile memory
OID
object identifier
OS
operating system
Acronyms and abbreviations 54
Download from Www.Somanuals.com. All Manuals Search And Download.
OSI
Open Systems Interconnection
POST
Power-On Self Test
PXE
Preboot Execution Environment
RADIUS
Remote Authentication Dial-In User Service
RAS
remote access service
RFC
request for comments
RMON
remote monitoring
RSTP
Rapid Spanning Tree Protocol
SCP
Secure Copy
SNMP
Simple Network Management Protocol
SSH
Secure Shell
STP
Spanning Tree Protocol
TACACS+
Terminal Access Controller Access Control System Plus
TFTP
Trivial File Transfer Protocol
Acronyms and abbreviations 55
Download from Www.Somanuals.com. All Manuals Search And Download.
UDP
User Datagram Protocol
UFD
uplink failure detection
VID
VLAN ID
VLAN
virtual local-area network
Acronyms and abbreviations 56
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
G
accessing the switch serial console interface,
troubleshooting 48
architecture 9
H
HyperTerminal, troubleshooting 49
Auto-MDI/MDIX 13
I
B
IEEE 802.1 Q-based Virtual Local Area Network 10
IGMP snooping 13
boot code firmware image, performing a serial
BOOTP server, troubleshooting 49
installing the switch 16
J
C
L
configuration, troubleshooting 52
configuring multiple switches, using a configuration
configuring multiple switches, using scripted CLI
laser compliance 26
Layer 2 switching 10
link LED, troubleshooting 48
N
D
default settings 28
diagnostic tools 9
O
operating system firmware, performing a serial
overview, product 6
E
external components 14
P
F
Index 57
Download from Www.Somanuals.com. All Manuals Search And Download.
R
U
V
Remote Authentication Dial-in User Service
VLANs, troubleshooting 51
X
replacing the switch 22
RJ-45 pin specification 46
runtime switching software, default settings 28
S
security features 17
Simple Network Management Protocol (SNMP) 11,
SNMP interface, troubleshooting 50
SNMP MIBs support 42
SNMP MIBs, supported 43
SNMP traps, supported 43
Spanning Tree Protocol (STP) 10
specifications, environmental 35
specifications, physical 35
specifications, technical 27
supported SNMP MIBs 43
supported technologies 10
switch redundancy 8
switch self-test, troubleshooting 48
T
Telnet, troubleshooting 49
Terminal Access Controller Access Control System
Plus (TACACS+) 12
Trivial File Transfer Protocol (TFTP) 11
troubleshooting 47
Index 58
Download from Www.Somanuals.com. All Manuals Search And Download.
|