Grandstream Networks Telephone Accessories HT286 User Manual

BroadSoft Partner Configuration Guide  
Grandstream HT286/386/486/488/496  
Analog Telephone Adapter  
&
BT100 SIP Phone  
October 2007  
Document Version 1.2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Document Revision History  
Version  
1.1  
Reason for Change  
Introduced document for HT496 version 1.0.3.96 validation with BroadWorks R14.SP2  
Added HT286/386/486/488/BT-100 models.  
1.2  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 3 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 4 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Overview  
This document describes the configuration procedures required for a Grandstream HT-  
286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 to make full use of the capabilities of  
BroadWorks.  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 is one of the many access  
devices that interoperate with BroadWorks.  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 uses the Session Initiation  
Protocol (SIP) to communicate with BroadWorks for call control. It also translates voice to  
audio packets for transmission across a packet network.  
This guide describes the specific configuration items that are important for use with  
BroadWorks. It does not describe the purpose and use of all configuration items on the  
HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100. For those details, see the HT-286  
/ HT-386 / HT-486 / HT-488 / HT-496 / BT-100 User Manual supplied by Grandstream  
Error! Reference source not found..  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 5 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
BroadWorks Validation Package Support Level  
Devices are validated according to BroadWorks Validation Packages. Each package  
validates a subset of features or items. This section describes the device’s support level  
for a BroadWorks Validation Package as well as the features or items in the package that  
are not supported. For specific issues, see section 3.2 Interoperability Issues. For a  
BroadWorks Package  
Basic Call  
Support Level  
Full  
Items Not Supported  
BroadWorks Enhanced Services  
Partial  
Ring Splash  
Priority Alerting  
Priority Call Waiting  
Alternate Numbers  
Advanced Call Control  
DUT Services – Call Control  
Partial  
Partial  
Network Conference 3-Way  
Network Conference N-Way  
DUT Services – Registration and  
Authentication  
BroadWorks Authentication  
DUT Services – FAX  
DUT Services – Busy Lamp Field  
Redundancy  
Full  
None  
Partial  
Call Setup Failover  
Mid-Call Failover  
SBC/ALG  
Full  
Shared Call Appearance  
None  
None  
None  
None  
Feature Key Synchronization  
Video  
TCP  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 6 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3
Device Capabilities and Known Interoperability Issues  
This section describes the features supported by the HT-286 / HT-386 / HT-486 / HT-488 /  
HT-496 / BT-100, as well as BroadWorks interoperability issues and impact. The following  
table describes capabilities.  
Verified Revisions shows the results of partner (vendor) testing of a specific BroadWorks  
version with a specific partner’s device under test (DUT) version.  
Compatible Revisions indicates the maintenance versions that should interface properly  
with BroadWorks.  
3.1 Capabilities  
Device Type  
Lines and Appearances  
SIP ATA  
HT-286: 1 line  
1 appearance per line  
HT-386: 2 lines 1 appearance per line  
HT-486: 1 line  
HT-486: 1 line  
1 appearance per line  
1 appearance per line  
HT-496: 2 lines 1 appearance per line  
BT-100: 1 line  
1 appearance per line  
Speaker/Power/Bridge  
HT-286: No/No/Yes  
HT-386: No/No/Yes  
HT-486: No/No/Yes  
HT-488: No/No/Yes  
HT-496: No/No/Yes  
BT-100: Yes/No/Yes  
Indicates speaker phone, in-line power, device  
bridge/conference.  
Verified Revisions  
BroadWorks Release: 14.SP2  
Grandstream HT-286: 1.1.0.8  
Grandstream HT-386: 1.0.3.96  
Grandstream HT-486: 1.1.0.8  
Grandstream HT-488: 1.0.3.96  
Grandstream HT-496: 1.0.3.96  
Grandstream BT-100: 1.1.0.8  
Compatible Revisions  
BroadWorks Release: 14.SP2  
Grandstream HT-286: any maintenance version of  
1.1.0.8  
Grandstream HT-386: any maintenance version of  
1.0.3.96  
Grandstream HT-486: any maintenance version of  
1.1.0.8  
Grandstream HT-488: any maintenance version of  
1.0.3.96  
Grandstream HT496: any maintenance version of  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 7 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1.0.3.96  
Grandstream BT-100: any maintenance version of  
1.1.0.8  
SIP Proxy FQDN DNS Lookup  
(A, SRV, NAPTR)  
A, SRV  
Outbound Proxy Configurable  
Yes  
Outbound Proxy FQDN DNS Lookup  
(A, SRV, NAPTR)  
A, SRV  
BroadWorks Redundancy Enabled  
BroadWorks Shared Call Appearance  
No  
N/A  
No  
BroadWorks Enhanced IP Phone  
Configuration  
Device Services  
Call Forwarding, Call Transfer, 3-Way Conference, Call  
Waiting, Call Hold  
Device Call Control  
Device-Controlled  
(Device-Controlled or Flash INFO-  
based)  
Codecs  
RFC 2833 DTMF  
T.38 Fax  
TCP  
PCMU, PCMA, G723.1 G729A/B, iLBC, G726-32  
Yes  
Yes  
No  
TLS  
No  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 8 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.2 Interoperability Issues  
This section lists the known interoperability issues between BroadWorks and partner  
release(s). For more information on issues related to the particular software release, see  
the partner release notes.  
None.  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 9 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
4
BroadWorks Device Identity/Profile  
BroadWorks configurable device identify/profile is introduced in BroadWorks Release  
14.0. This section applies only to BroadWorks Release 14.0 and later.  
The following table identifies the required BroadWorks device identity/profile settings for  
interoperability between the HT496 and BroadWorks. For an explanation of the profile  
parameters, refer to the BroadWorks Device Inventory Guide [4].  
For most of the parameters below, an “X” indicates the parameter function is supported  
and/or required. If the item is blank, it is not supported.  
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100  
Identify/Device Profile  
Signaling Address Type  
Number of Lines  
Intelligent Proxy Addressing  
HT-286/HT-486/BT-100: 1 line  
HT-386/HT-488/HT-496: 2 lines  
Ringback Tone/ Early Media  
Support  
Local Ringback – No Early Media  
Authentication  
Enabled  
X
Registration Capable  
Static Registration Capable  
E.164 Capable  
Trusted  
Authenticate REFER  
Authentication Override  
Video Capable  
X
X
RFC 3264 Hold  
Route Advance  
Wireless Integration  
PBX Integration  
Use Business Trunking Contact  
Forwarding Override  
Conference Device  
Music On Hold Device  
Auto Configuration Soft Client  
Web Based Configuration URL  
Auto Configuration Type  
Reset Event  
http//:%BWIPADDRESS%  
2 Config File  
checkSync  
Enable Monitoring  
CPE System File Name  
ataSystem.txt/bt100System.txt  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 10 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Device File Format  
%BWMACADDRESS%.txt  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 11 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
BroadWorks Device Type  
This section applies to BroadWorks Release 13.0 and before.  
The following BroadWorks device type should be used for Grandstream HT-286 / HT-386  
/ HT-486 / HT-488 / HT-496 / BT-100.  
Grandstream HT-286  
Grandstream HT-386  
Grandstream HT-486  
Grandstream HT-488  
Grandstream HT-496  
Grandstream BT-100  
The above device types require BroadWorks Release 13 MP<patch number>. If the  
BroadWorks system is currently at a lower patch level, either apply the necessary patch or  
use the following generic device type until the system can be patched accordingly.  
Generic SIP Smart (Proxy Addr)  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 12 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
Configuration  
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured  
via Web GUI Interface as well as via Configuration File through TFTP or HTTP.  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 accepts configuration files in a  
proprietary binary format which is produced by the Grandstream configuration tool. The  
configuration tool creates a device configuration file based on a configuration template and  
the device’s MAC address. All Grandstream products’ sample configuration templates are  
available on Grandstream’s web site. A configuration template file contains all  
configuration parameters available for a product, with comments describing allowed  
values of the parameters. For a detailed parameter list, please refer to the corresponding  
firmware release configuration template [2].  
When Grandstream device boots up or reboots, it will issue request for a binary  
configuration file named “cfgxxxxxxxxxxxx”, where “xxxxxxxxxxxx” is the MAC address of  
the device, i.e., “cfg000b820102ab”. The configuration file name should be in lower cases.  
Grandstream offers free Configuration File generator software in both Linux/Unix and  
Windows platform. Both Configuration File Generators can be downloaded from  
Grandstream official web site at http://www.grandstream.com/configurationtool.html [2].  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 can be configured with a  
configuration file using the Trivial File Transfer Protocol (TFTP) or through its embedded  
web server. The following examples describe how to set the parameters using a  
configuration file. This configuration description assumes the HT-286 / HT-386 / HT-486 /  
HT-488 / HT-496 / BT-100 will use the Dynamic Host Configuration Protocol (DHCP) to  
obtain an IP address and other network settings. The HT-286 / HT-386 / HT-486 / HT-488  
/ HT-496 / BT-100 should be configured to load the configuration file each time it resets or  
re-synchronizes. For detailed information on automated provisioning, please check the  
HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 User Manual Error! Reference  
source not found..  
The capabilities of the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 have been  
verified for use with BroadWorks based on the settings described in the following table.  
For more information on the meaning, purpose, and applicability of the individual  
configuration items, see the HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100  
configuration template [2] .  
Configuration Files  
Files Provided by Partner  
Level  
Description  
HT-286 / HT-386 / HT-486 / HT-488 / HT-  
496 / BT-100 Configuration Template  
System and  
Subscriber  
Contains configurable parameters that  
apply to an individual device in a  
deployment.  
Example: sipp1_config_1.1.0.8.txt  
sipp2_config_1.0.3.96.txt  
cfgMAC  
System and  
Subscriber  
Binary configuration file generated  
from configuration template and an  
individual device’s MAC address.  
Example: cfg000b82000000  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 13 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6.1 System Level Configuration  
This section describes system-wide configuration items that are generally required for  
each HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 to work with BroadWorks.  
Subscriber-specific settings are described in the next section.  
{THIS IS JUST AN EXAMPLE AND IS NOT INTENDED AS A COMPLETE OR  
SUFFICIENT TABLE OF PARAMETERS. EACH DEVICE WILL VARY AND MAY BE  
COMPLETELY DIFFERENT. IF YOUR DEVICE DOES NOT SUPPORT CONFIG  
FILES USE GUI CAPTURES OR OTHER METHODS TO DESCRIBE THE  
CONFIGURATION.}  
Step  
Command  
Purpose  
System Configuration Items  
Set SIP Proxy/Domain.  
Step 1  
Set the HT-286 / HT-386 / HT-  
486 / HT-488 / HT-496 / BT-100  
SIP server to the Fully Qualified  
Domain Name (FQDN) for the  
BroadWorks Application Server  
cluster.  
sipProxy = as.broadworks.net  
The domain must match the  
domain configured for the  
BroadWorks subscriber’s  
line/port domain.  
Set Outbound Proxy.  
Step 2  
Set the outbound proxy to the  
session border controller (SBC)  
if one is deployed between the  
HT-286 / HT-386 / HT-486 / HT-  
488 / HT-496 / BT-100 and  
BroadWorks.  
outBoundProxy =  
sbc.broadworks.net  
If there are redundant SBCs, set  
it to the FQDN for the SBC  
cluster.  
Enable DNS SRV lookup.  
Step 3  
Step 4  
Step 5  
Step 6  
Enable DNS SRV lookups.  
Use_DNS_SRV = “Yes” ;  
Set register mode.  
Enable SIP register.  
SIP Registration = “Yes”  
Set SIP Timers.  
The default registration period is  
60 minutes.  
Register Expiration = 60  
Enable negotiated DTMF type.  
Send DTMF = “via RTP (RFC2833)”  
Set the HT-286 / HT-386 / HT-  
486 / HT-488 / HT-496 / BT-100  
to enable inband or RFC 2833  
negotiated DTMF.  
Disable local feature code  
services.  
Step 7  
Step 8  
Disable feature access codes  
controlled by the device.  
Enable Call Features = “No”  
Enable BroadSoft mode.  
Set the HT-286 / HT-386 / HT-  
486 / HT-488 / HT-496 / BT-100  
in BroadSoft mode.  
Special Feature = “Broadsoft”  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 14 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6.2 Subscriber Level Configuration Parameters  
This section identifies the device-specific parameters, including registration and  
authentication. These settings must be unique across devices in order to be matched with  
the settings for a BroadWorks subscriber.  
Provisioning a subscriber to register with BroadWorks allows calls to terminate to the  
subscriber’s line. Registration requires that a unique address of record (AoR) is  
provisioned on BroadWorks and the phone; provisioning an AoR on BroadWorks consists  
of setting the line/port parameter to a unique value within the Application Server cluster.  
Grandstream HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 supports one SIP  
accounts (lines), two SIP accounts, one SIP account, two SIP accounts, two SIP  
accounts, and 1 SIP account, respectively. The follow example shows how to configure  
subscriber elements for an account.  
Step  
Command  
Purpose  
Subscriber Configuration Items  
Set Register User ID for each  
line.  
Step 1  
Step 2  
The register user ID must  
correspond with the line/port  
setting on BroadWorks.  
Example:  
SIP User_ID = "2405551111" ;  
Enable SIP Authentication for  
each line.  
If the Authentication service is  
configured on BroadWorks, these  
parameters must be configured to  
match the BroadWorks settings.  
Example:  
Authenticate ID =  
Authenticate Password =  
"welcome"  
;
Configure display name for each  
line.  
Step 3  
For each line, configure the name  
to be displayed on the device.  
Example:  
Name = “Claire Smith” ;  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 15 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
7
Enhanced IP Phone Configuration  
Enhanced IP Phone Configuration is a BroadWorks feature that enables automatic  
generation of device configuration files, given administrator-supplied templates.  
For more information on the Enhanced IP Phone Configuration feature, see the Enhanced  
IP Phone Configuration Guide [3].  
The HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 uses only a phone-specific file  
to configure the device. However, the Enhanced IP Phone Configuration feature requires  
a system and a phone-specific file for each device. To satisfy the system file requirement,  
an empty file (ataDefault.txt, bt100Desfult.txt) will need to be uploaded to BroadWorks as  
the system file. This file will be sent to the FTP server but will not actually be used for the  
configuration file generation. The group template file is used to build the configuration files  
for the devices of this device type assigned to the group. For a sample HT-286 / HT-386 /  
HT-486 / HT-488 / HT-496 / BT-100 group template file, see Appendix A.  
NOTE: BroadSoft does not manage or distribute template files for use with the Enhanced IP  
Phone Configuration feature. Obtain template files from Grandstream or use the configuration  
files obtained from Grandstream for the specific Grandstream firmware release to create  
template files appropriate for your installation.  
Since HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100 require the configuration files be  
converted into a binary format, an extra step must be performed when using this feature. After  
the configuration files have been sent to the TFTP server and before the phone is reset, the  
configuration files must be converted to binary format using Grandstreams configuration tool.  
For detailed information on automated provisioning, please check the Grandstream configuration  
tool user guide [2].  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 16 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix A: Sample HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-100  
Configuration Files  
NOTE: The following samples are examples and should be used as a reference only. DO NOT CUT  
AND PASTE THESE EXAMPLES TO GENERATE YOUR CONFIGURATION FILES. Use the  
configuration files obtained from Grandstream with the specific release to generate your configuration  
files.  
System Default Parameters:  
NOTE: This is an example file and should be used for reference only.  
# SIP Default Generic Configuration File  
####################################################  
# Account 1  
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #  
####################################################  
# SIP Server  
P47 = as.broadworks.net  
# Outbound Proxy  
P48 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P103 = 1  
# SIP Registration. 0 - no, 1 - yes  
P31 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P32 = 60  
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO  
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP  
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO  
P73 = 1  
# Enable Call Features. 0 - no, 1 – yes  
P191 = 0  
# Special Feature. 102 – BroadSoft  
P198 = 102  
####################################################  
# Account 2  
#
#
#
####################################################  
# SIP Server  
P747 = as.broadworks.net  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 17 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
# Outbound Proxy  
P748 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P702 = 1  
# SIP Registration. 0 - no, 1 – yes  
P731 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P732 = 60  
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO  
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP  
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO  
P773 = 1  
# Enable Call Features. 0 - no, 1 – yes  
P751 = 0  
# Special Feature. 102 – BroadSoft  
P767 = 102  
Phone-Specific Parameters:  
NOTE: This is an example file and should be used for reference only.  
# SIP Device-specific Configuration File  
####################################################  
# Account 1  
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #  
####################################################  
# SIP User ID  
P35 = 2405551111  
# Authenticate ID  
# Authenticate password  
P34 = welcome  
# Display Name  
P3 = Claire Smith  
####################################################  
# Account 2  
#
#
#
####################################################  
# SIP User ID  
P735 =  
# Authenticate ID  
P736 =  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 18 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
# Authenticate Password  
P734 =  
# Display Name  
P703 =  
Group Template File: ATA-GroupTemplate.txt /BT100- GroupTemplate.txt  
NOTE: This is an example file and should be used for reference only.  
####################################################  
# SIP Default Generic Configuration Parameters  
#
####################################################  
####################################################  
# Account 1  
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #  
####################################################  
# SIP Server  
P47 = as.broadworks.net  
# Outbound Proxy  
P48 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P103 = 1  
# SIP Registration. 0 - no, 1 - yes  
P31 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P32 = 60  
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO  
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP  
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO  
P73 = 1  
# Enable Call Features. 0 - no, 1 – yes  
P191 = 0  
# Special Feature. 102 – BroadSoft  
P198 = 102  
####################################################  
# Account 2  
#
#
#
####################################################  
# SIP Server  
P747 = as.broadworks.net  
# Outbound Proxy  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 19 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P748 = sbc.broadworks.net  
# Use DNS SRV. 0 - no, 1 - yes.  
P702 = 1  
# SIP Registration. 0 - no, 1 – yes  
P731 = 1  
# Register Expiration (in minutes. default 1 hour, max 45 days)  
P732 = 60  
# Send DTMF. 8 - in audio, 1 - via RTP, 2 - via SIP INFO  
# 11 - In Audio & RTP & SIP INFO, 9 - In Audio & RTP  
# 10 - IN Audio & SIP INFO, 3 - RTP & SIP INFO  
P773 = 1  
# Enable Call Features. 0 - no, 1 – yes  
P751 = 0  
# Special Feature. 102 – BroadSoft  
P767 = 102  
####################################################  
# SIP Device-specific Configuration Parameters  
#
####################################################  
####################################################  
# Account 1  
#
# HT-286 / HT-486 / BT-100 supports Account 1 only #  
####################################################  
# SIP User ID  
P35 = %BWLINEPORT-1%  
# Authenticate ID  
P36 = %BWAUTHUSER-1%  
# Authenticate password  
P34 = %BWAUTHPASSWORD-1%  
# Display Name (John Doe)  
P3 = %BWCLID-1%  
####################################################  
# Account 2  
#
#
#
####################################################  
# SIP User ID  
P735 = %BWLINEPORT-2%  
# Authenticate ID  
P736 = %BWAUTHUSER-2%  
# Authenticate Password  
P734 = %BWAUTHPASSWORD-2%  
# Display Name (John Doe)  
P703 = %BWCLID-2%  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 20 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix B: BroadWorks Validation Package Test Items  
The following table describes the items tested in each BroadWorks Validation Package.  
BroadWorks Validation Package  
Items Supported  
Basic Call  
Basic Call Origination / Termination  
Call Failure Codes  
Session Audit  
Ringback  
Dial Plan  
Inband DTMF  
RFC 2833/Negotiation  
DTMF Relay  
Codec Renegotiation  
BroadWorks Enhanced Services  
Basic CommPilot Call Manager Functions  
Voice Messaging Audio MWI  
Voice Messaging Visual MWI  
Ring Splash  
Priority Alerting  
Priority Call Waiting  
Alternate Numbers  
Advanced Call Control  
Anonymous Call  
Remote Restart  
Call Park Retrieve – Answer with Hold  
DUT Services – Call Control  
Call Waiting  
Call Hold  
Blind Transfer  
Attended Transfer  
3-Way Call  
Network Conference 3-Way  
Network Conference N-Way  
DUT Services – Registration and  
Authentication  
Authenticated Registration  
Maximum Registration  
Minimum Registration  
Rejected Registration  
Authenticated Origination  
Authenticated Re-INVITE  
Authenticated REFER  
BroadWorks Authentication  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 21 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
BroadWorks Validation Package  
Items Supported  
DUT Services - FAX  
FAX Passthrough  
FAX T38  
DUT Services – Busy Lamp Field  
Redundancy  
Basic BLF  
DNS  
Registration Failover  
Call Setup Failover  
Mid-Call Failover  
SBC/ALG  
Registration  
Call Origination  
Call Termination  
Shared Call Appearance  
Line Seize  
Line Lamp Management  
Line Hold/Retrieve  
Multiple Call Arrangement  
SCA Bridging  
Feature Key Synchronization  
Video  
Feature Key Synchronization  
Integrated Video Phone  
Video Services  
Video Add-On  
TCP  
Basic  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 22 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
References  
[1] Grandstream Networks, Inc. 2007. HT-286 / HT-386 / HT-486 / HT-488 / HT-496 / BT-  
100 User Manual. Download at:  
AND GUI Interfaces:  
[2] Grandstream Networks, Inc. 2007. Grandstream Configuration Tool and Templates.  
[3] BroadSoft, Inc. 2006. BroadWorks Enhanced IP Phone Configuration Guide,  
Release 14.0. Available from BroadSoft at www.broadsoft.com/boulevard.  
[4] BroadSoft, Inc. 2006. BroadWorks Device Inventory Guide, Release 14.0. Available  
[5] BroadSoft, Inc. 2006. BroadWorks Redundancy Guide, Release 14.0. Available  
BROADSOFT PARTNER CONFIGURATION GUIDE – GRANDSTREAM HT286/386/486/488/496/BT100  
©2007 GRANDSTREAM. PROPRIETARY AND CONFIDENTIAL; DO NOT DUPLICATE, OR DISTRIBUTE.  
DOCUMENT NUMBER  
PAGE 23 OF 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       

Greenheck Fan Fan 474051 User Manual
Grizzly DVR G9947 User Manual
Grizzly Home Safety Product H8239 User Manual
Grundig Hot Beverage Maker WK 4062 User Manual
Hamilton Electronics Stud Sensor EPHUM011 User Manual
HANNspree Flat Panel Television ST48 12A1 User Manual
Hans Grohe Plumbing Product 42234000 User Manual
Honeywell Air Cleaner F111 Series 3 User Manual
HP Hewlett Packard Car Stereo System A6829A User Manual
Hunter Fan Air Cleaner 30849 User Manual