Graco Inc Marine Heating System 332073C User Manual

Instructions-Parts  
XMPFP  
Hot Water Flush Kit  
332073C  
EN  
For flushing the XM PFP system with hot water. For professional use only.  
100 psi (0.7 MPa, 7 bar) Maximum Inlet Water Pressure to Float Valve  
180°F (82°C) Maximum Outlet Fluid Temperature  
Important Safety Instructions  
Read all warnings and instructions in this manual and  
the XM PFP Operation manual. Save all instructions.  
See Models, page 2 for more information.  
WLꢀꢁꢂꢂꢀD  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnings  
Warnings  
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-  
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When  
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific  
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where  
applicable.  
FIRE AND EXPLOSION HAZARD  
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent  
flowing through the equipment can cause static sparking. To help prevent fire and explosion:  
Use equipment only in well ventilated area.  
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop  
cloths (potential static sparking).  
Ground all equipment in the work area. See Grounding instructions.  
Never spray or flush solvent at high pressure.  
Keep work area free of debris, including solvent, rags and gasoline.  
Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes  
are present.  
Use only grounded hoses.  
Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are  
anti-static or conductive.  
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until  
you identify and correct the problem.  
Keep a working fire extinguisher in the work area.  
ELECTRIC SHOCK HAZARD  
This equipment must be grounded. Improper grounding, setup, or usage of the system can cause  
electric shock.  
Turn off and disconnect power at main switch before disconnecting any cables and before servicing  
or installing equipment.  
Connect only to grounded power source.  
All electrical wiring must be done by a qualified electrician and comply with all local codes and  
regulations.  
SKIN INJECTION HAZARD  
High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just  
a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.  
Do not spray without tip guard and trigger guard installed.  
Engage trigger lock when not spraying.  
Do not point gun at anyone or at any part of the body.  
Do not put your hand over the spray tip.  
Do not stop or deflect leaks with your hand, body, glove, or rag.  
Follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or  
servicing equipment.  
Tighten all fluid connections before operating the equipment.  
Check hoses and couplings daily. Replace worn or damaged parts immediately.  
332073C  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warnings  
BURN HAZARD  
Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe  
burns:  
Do not touch hot fluid or equipment.  
EQUIPMENT MISUSE HAZARD  
Misuse can cause death or serious injury.  
Do not operate the unit when fatigued or under the influence of drugs or alcohol.  
Do not exceed the maximum working pressure or temperature rating of the lowest rated system  
component. See Technical Data in all equipment manuals.  
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all  
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information  
about your material, request Safety Data Sheet (SDS) from distributor or retailer.  
Do not leave the work area while equipment is energized or under pressure.  
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.  
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-  
facturer’s replacement parts only.  
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create  
safety hazards.  
Make sure all equipment is rated and approved for the environment in which you are using it.  
Use equipment only for its intended purpose. Call your distributor for information.  
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.  
Do not kink or over bend hoses or use hoses to pull equipment.  
Keep children and animals away from work area.  
Comply with all applicable safety regulations.  
PERSONAL PROTECTIVE EQUIPMENT  
Wear appropriate protective equipment when in the work area to help prevent serious injury, including  
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is  
not limited to:  
Protective eyewear, and hearing protection.  
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer  
4
332073C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Component Identification  
Component Identification  
%
*
&
Key:  
A
B
C
D
3/4 NFR Garden Hose Inlet  
Heater  
Pump  
Hot Water Outlet to Flush  
Pump  
'
E
F
Tank  
Suction Hose (see  
installation)  
G
Air Hose  
)
(
$
WLꢀꢁꢂꢂꢃE  
FIG. 1  
Hazardous Location XM PFP  
Non-Hazardous Location XM PFP  
WLꢀꢁꢆꢇꢇD  
WLꢀꢄꢃꢃꢅE  
FIG. 2: Heater Power Cable  
332073C  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
2. Use four bolts and nuts (4, 5) to install tank (1) onto  
bracket (2).  
Installation  
3. Follow Connect Air Supply, page 8. Connect air  
hose (8) to circulation pump (53) and diaphragm  
pump (P) on the PFP system.  
The equipment must be grounded to reduce the risk  
of static sparking and electric shock. Electric or static  
sparking can cause fumes to ignite or explode.  
Improper grounding can cause electric shock.  
Grounding provides an escape wire for the electric  
current.  
4. Connect suction hose (F) to the flush pump and  
insert in the hot water flush tank.  
5. Connect heater power cable.  
a. Model 24Y132: With the heater ON/OFF toggle  
switch (H) OFF, connect power cable to the  
corded receptacle hanging below the junction  
box on the XM PFP sprayer.  
b. Model 24X113: With the heater ON/OFF toggle  
switch (H) OFF, route the heater power cable  
through the Flush Heater cord grip. See FIG. 2,  
page 5. See system manual for power connec-  
tion.  
Optional Location 1  
1. Use four bolts (4) to install the bracket (2) onto the  
system frame.  
+
)
ꢁꢃ  
WLꢀꢁꢂꢂꢁE  
P
FIG. 3: Optional Location 1  
6
332073C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
5. Connect suction hose (F) to the flush pump and  
Optional Location 2  
insert in the hot water flush tank.  
6. Connect heater power cable.  
a. Model 24Y132: Connect With the heater  
ON/OFF toggle switch (H) OFF, connect power  
cable to the corded receptacle hanging below  
the junction box on the XM PFP sprayer.  
1. Use four bolts (4) to connect the three bracket  
pieces (2, 6, 7).  
2. Use four bolts (4 to install the bracket assembly (2)  
onto system frame.  
b. Model 24X113: With the heater ON/OFF toggle  
switch (H) OFF, route the heater power cable  
through the Flush Heater cord grip. See FIG. 2,  
page 5. See system manual for power connec-  
tion.  
3. Use four bolts and nuts (4, 5) to install tank (1) onto  
bracket assembly (2).  
4. Follow Connect Air Supply, page 8.  
)
ꢁꢃ  
P
WLꢀꢁꢂꢂꢄE  
FIG. 4: Optional Location 2  
332073C  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Connect Air Supply  
Connect Air Supply  
1. Disconnect air supply (AS) from Heated Fluid Circu-  
lation Pump (P) for hose bundle.  
5. Connect the air hose (8) to the nipple fitting (10).  
See #2 in FIG. 5. Connect the air hose (8) to the hot  
water circulation pump (53).  
2. For Model 24Y132: install the tee (9), nipple (10).  
The cap (11) is not used.  
AS  
$6  
11  
8
P
53  
WLꢀꢄꢂꢆꢆD  
8
FIG. 6:  
WLꢀꢄꢉꢇꢇD  
ꢅꢅ  
8
ꢀꢊ  
ꢅꢊ  
$6  
ꢅꢇ  
Connect Water Supply  
1. Connect garden hose to a water supply and the  
water inlet (A). See FIG. 1, page 5.  
P
P
$6  
FIG. 5:  
3. For Model 24X113:  
a. Remove cap (11).  
4. Connect air hose (8) to circulation pump (53) and  
diaphragm pump (P) on the PFP system. See FIG. 3  
on page 6 or FIG. 4 on page 7.  
8
332073C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Priming the Heater  
Priming the Heater  
Equipment surfaces and fluid that is heated can  
become very hot during operation. To avoid burns and  
fire and explosions:  
• Do not touch hot fluid or equipment.  
• Only use water.  
NOTICE  
To prevent damaging the heater element, never  
turn on the heater without it completely filled with  
water.  
1. Turn on water supply.  
2. Loosen needle valve on diaphragm pump to pump  
water through the heater.  
3. Turn the heated water flush switch on the XM PFP  
sprayer to the ON position. The switch is located  
next to the main power switch above the dosing  
valves.  
NOTICE  
To prevent damage to the diaphragm pump, never  
turn the heater dial past 9.  
4. Use the dial on the heater to set desired tempera-  
ture. See table.  
Heater Dial  
Tank Temperature °F(°C)  
9
8
7
6
5
180 (82)  
160 (71)  
140 (60)  
120 (48)  
100 (37)  
5. Turn on XM PFP flush pump ON to begin running  
water through the pump.  
6. Spray until the water is dispensed from the gun.  
7. Continue flushing as necessary.  
332073C  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Parts  
Hazardous Location Hot Water Flush Kit, 24X113  
Non Hazardous Location Hot Water Flush Kit, 24Y132  
ꢂꢈ  
ꢂꢁ  
ꢂꢄ  
ꢂꢀ  
ꢁꢁ  
ꢁꢄ  
ꢁꢂ  
ꢁꢈ  
ꢁꢀ  
ꢂꢉ  
ꢁꢆ  
ꢁꢉ  
ꢄꢇ  
ꢄꢅ  
ꢄꢂ  
ꢂꢇ  
ꢂꢅ  
ꢄꢀ  
ꢄꢃ  
ꢅꢅ  
ꢅꢇ  
ꢄꢆ  
ꢄꢈ  
ꢂꢆ  
ꢂꢃ  
ꢄꢉ  
ꢄꢄ  
ꢄꢉ  
ꢄꢂ  
WLꢀꢁꢂꢂꢂF  
ꢁꢃ  
ꢄꢁ  
NOTE: Use sealant on all pipe threads.  
10  
332073C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Hazardous Hot Water Flush Kit, 24X113  
Hazardous Water Heated Tank, 262937  
Non Hazardous Hot Water Flush Kit, 24Y132  
Non Hazardous Water Heated Tank, 262946  
Ref Part  
Description  
Qty Ref Part  
Description  
Qty  
1
1
262937 TANK, heated, water  
1
1
1
4
8
4
1
1
1
1
51 17B562 TANK, heated, water  
52 245863 HEATER (262937 only)  
245869 HEATER (262946 only)  
53 24T761 PUMP, Husky  
54 24W679 CABLE, assembly (262937 only)  
17G071 CABLE, assembly (262946 only)  
262946 TANK, heated water  
1
1
1
1
2
3
4
5
6
7
8
9
17B717 BRACKET, mount  
121488 SCREW, hex head, flanged  
112395 SCREW, cap, flange head  
112958 NUT, hex, flanged  
256254 BRACKET, hopper, b-mt  
256256 BRACKET, hopper, b-mt, lower  
248208 HOSE, coupled, 4 ft (1.2 m)  
116504 FITTING, tee, run, 1/4 npt(m) x 1/4  
npt(m) x 1/4 npt(f)  
55* 24W654 VALVE, body, float  
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
56* 24W655 ROD, float, 8 in (203 mm)  
57* 24W656 FLOAT, round, copper  
58 156849 PIPE, nipple  
59 111856 FITTING, elbow, street  
60 237534 VALVE, ball, 316 sst  
10 156971 FITTING, nipple, short, 2 x 1/4-18 npt  
11 16X167 FITTING, cap, hex 1/4 npt(f)  
--- Not for sale.  
1
61 100081 BUSHING, pipe  
62 16T886 ADAPTER, 3/4 NFR to 1/2 npt  
63 115099 WASHER, garden hose  
64 16G248 FITTING, plug, 1/2 npt  
65 206264 VALVE, needle  
66 16D939 FITTING, nipple, reducing  
67 126898 FITTING, elbow, 1/2 tube x 1/2 nptm  
68 126897 FITTING, elbow, 1/2 tube x 1/4 nptm  
69 126896 FITTING, elbow, 1/2 tube x 1/2 nptf  
Replacement Danger and Warning labels, tags and  
cards are available at no cost.  
70 ---  
TUBE, blue, nylon 0.375 (9.5 mm) ID;  
3 ft (1 m)  
71 ---  
TUBE, red, nylon 0.375 (9.5 mm) ID; 1  
ft (0.3 m)  
1
72 17B563 COVER, tank  
73189285 LABEL, hot  
74 117499 HANDLE, large  
75 106084 SCREW, mach, pn hd  
76 17C670 STRAP, rubber, 19 in (482.6 mm)  
77 121603 GRIP, cord (262946 only)  
7817D817 LABEL, safety, warning, water only  
79 17D135 SCREW, hex, hi-lo, thread forming  
1
1
1
2
1
1
2
4
Replacement Danger and Warning labels, tags and  
cards are available at no cost.  
*
Parts included in the Water Rod Float Valve Kit  
24Y096.  
332073C  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Data  
Technical Data  
PFP Hot Water Flush Kit  
US  
Metric  
7 MPa, 7 bar  
Maximum Water Inlet Pressure to Float Valve 100 psi  
Maximum Outlet Fluid Temperature  
Supply Voltage  
Power  
180°F  
82°C  
220-250 Volts AC, 1 phase  
4000 Watts  
Tank Size  
10 gallon  
37.8 liter  
Inlet Fitting  
3/4 NHR Garden Hose  
Wetted Parts  
Plated Carbon steel, stainless steel, brass  
12  
332073C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Technical Data  
332073C  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graco Standard Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written  
recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty  
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of  
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with  
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or  
maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of  
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned  
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs  
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT  
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy  
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or  
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.  
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT  
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to  
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these  
warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or  
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the  
negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,  
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la  
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite  
de ou en rapport, directement ou indirectement, avec les procédures concernées.  
Graco Information  
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.  
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
This manual contains English. MM 332073  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA  
Copyright 2012, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.  
Revision C, July 2015  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Graco Baby Jumper 8740 User Manual
Gravely Lawn Mower CONVERTIBLE 76 User Manual
Hafler Car Amplifier DH 100 User Manual
Haier Air Conditioner 0010552537 User Manual
Honeywell Home Security System 800 04410 User Manual
Hotpoint Double Oven DX 892 CX User Manual
Hotpoint Washer Dryer WDL540 P G A K User Manual
HP Hewlett Packard Computer Monitor A6B85A8ABA User Manual
IBM Personal Computer 6058 User Manual
Impex Home Gym IVK 402 User Manual