Instructions - Parts List
50:1 Mini Fire-Ball
225 Grease Pump
309966J
EN
For pumping non-corrosive and non-abrasive greases and lubricants only. For
professional use only.
Not for use in explosive atmospheres.
Model No. 246909, Series C, Pail Length
Model No. 246780, Series C, 120-lb Drum Length
Model No. 246781, Series C, 400-lb Drum Length
Model No. 253361, Series C, Pail Length Without Handle
8400 psi (58 MPa, 580 bar) Maximum Working Pressure
140 psi (1.0 MPa, 10 bar) Maximum Air Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Table of Contents
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Graco Standard Warranty . . . . . . . . . . . . . . . . . . . 18
Model No. 246780 shown
9038B
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
WARNING
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
•
•
•
•
•
•
•
Use equipment only in well ventilated area.
Eliminate all ignition sources, such as cigarettes and portable electric lamps.
Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Ground all equipment in the work area.
Use only grounded hoses.
If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
TOXIC FLUID OR FUMES HAZARD
Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or
swallowed.
•
•
Read MSDS’s to know the specific hazards of the fluids you are using.
Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or when in the operating
area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic
fumes, burns, and hearing loss. This equipment includes but is not limited to:
•
•
•
•
Protective eyewear
Clothing and respirator as recommended by the fluid and solvent manufacturer
Gloves
Hearing protection
309966J
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
Grounding
Mounting
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, ground the pump.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment.
Mount the pump securely so that it cannot move
around during operation. Failure to do so could result in
personal injury or equipment damage.
Ground the following equipment:
•
Pump: Use a ground wire and clamp as shown in
FIG. 1.
1. Plan the mounting layout for easy operator access
to the pump air controls, sufficient room to change
drums and a secure mounting platform.
•
•
Fluid hoses: Use only electrically conductive hoses.
2. If using a follow plate (H), remove the drum cover.
Scoop the material to the center of the drum to
make the surface convex. Place the plate on the
material. Guide the pump foot valve through the
plate.
Air compressor: Follow the manufacturer’s recom-
mendations.
•
•
Fluid supply container: Follow the local code.
To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
valve firmly to the side of a grounded metal pail,
then trigger the valve.
3. Mount the pump to the drum cover or other suitable
mounting device.
4. Install a pump elevator for easier changing of
drums,
To ground the pump, remove the ground screw (Z)
and insert through the eye of the ring terminal at end of
the ground wire (Y). Fasten the ground screw back onto
the pump and tighten securely. Connect the other end of
the ground wire to a true earth ground. See FIG. 1. To
order a ground wire and clamp, order Part No. 222011.
Y
Z
TI1052
FIG. 1
4
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Air and Fluid Line and
Accessories
CAUTION
Do not hang the air accessories directly on the air
inlet. The fittings are not strong enough to support the
accessories and may cause one or more to break.
Provide a bracket on which to mount the accessories.
Install the air line accessories in the order shown in
Three accessories are required in your system: an air
shut-off valve/air bleed device, fluid drain valve, and
ground wire. These accessories help reduce the risk of
serious bodily injury, including skin injection, splashing
in the eyes or on the skin, injury from moving parts if you
are adjusting or repairing the pump, and explosion from
static sparking.
1. Install a pump runaway valve (G) to shut off the air
to the pump if the pump accelerates beyond the
pre-adjusted setting. A pump that runs too fast can
be seriously damaged.
2. Install an air line lubricator (F) for automatic air
motor lubrication.
•
The air bleed device relieves air trapped between it
and the air motor after the air supply is shut off.
Trapped air can cause the air motor to cycle unex-
pectedly, causing serious injury if you are adjusting
or repairing the pump. Use a bleed-type master air
valve (J), installed near the pump air inlet within
easy reach from the pump.
3. Install a bleed-type master air valve (J) to relieve air
trapped between the valve and the motor. Order
Part No. 107142.
4. Install an air regulator (C) to control pump speed
and pressure.
•
•
The fluid drain valve (K) assists in relieving fluid
pressure in the displacement pump, hoses, and dis-
pensing valve. Triggering the valve to relieve pres-
sure may not be sufficient.
5. Install an air line filter (E) to remove harmful dirt and
contaminants from your compressed air supply.
6. Install a second bleed-type master air valve (J)
upstream from all other accessories, to isolate the
accessories for servicing.
The ground wire (B) reduces the risk of static spark-
ing.
Typical Installation for Stationary Mountings
Recommended air line
configuration to reduce
moisture in pump
B
G
A
D
KEY
F
J
J
C
E
A
B
C
D
E
F
Fluid dispense line
Pump ground wire (required)
Air regulator with gauge
Main air supply line
Air line filter
K
H
Air line lubricator
G Pump runaway valve
H
J
Follower plate
Bleed-type master air valves
(required)
0 4 1 9 1 C
1/2 in.
K
Fluid drain valve
FIG. 2
309966J
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Operation
Pressure Relief Procedure
The pump has a rated ratio of 50:1. However, it is
capable of reaching stall pressures equal to 60
times the air input pressure. Calculate the fluid out-
put pressure using the air regulator reading. Multi-
ply the air pressure shown on the regulator gauge
by 60. For example:
The equipment stays pressurized until pressure is man-
ually relieved. To reduce the risk of serious injury from
pressurized fluid, fluid from the valve, or splashing fluid,
follow this procedure whenever you:
•
•
•
•
are instructed to relieve pressure
stop dispensing
check, clean, or service any system equipment
install or clean dispensing devices.
140 psi air x 60 = 8400 psi fluid output)
(0.97 MPa air = 58.2 MPa fluid output
99.7 bar air x 60 = 582 bar fluid output
1. Close the pump air regulator and the bleed–type
master air valve (required in your system).
Regulate air to the pump so that no air line or fluid
line component or accessory is overpressurized.
2. Hold a metal part of the dispensing valve firmly to a
grounded metal waste container and trigger the
valve to relieve the fluid pressure.
6. Never allow the pump to run dry of the material
being pumped.
Startup
CAUTION
1. If there are multiple pumps on the air line, close the
air regulators and bleed–type master air valves to all
but one pump. If there is only one pump, close its air
regulator and bleed–type master air valve.
A dry pump will quickly accelerate to a high speed,
possibly damaging itself. If your pump accelerates
quickly, or is running too fast, stop it immediately and
check the material supply. If the supply container is
empty and air has been pumped into the lines, prime
the pump and lines with material, or flush it and leave
it filled with a compatible solvent. Be sure to eliminate
all air from the material lines.
2. Open the master air valve from the compressor.
3. Open the dispensing valve into a grounded metal
waste container, making firm metal–to–metal con-
tact between the container and valve. Open the
bleed–type master air valve and open the pump air
regulator slowly, just until the pump is running.
When the pump is primed and all air has been
pushed out of the lines, close the dispense valve.
A pump runaway valve can be installed on the air
line to automatically shut off the pump if it starts to
run too fast.
4. If you have more than one pump, repeat this proce-
dure for each pump.
7. Read and follow the instructions supplied with each
component in your system.
8. To shut off the system, always follow the Pressure
Relief Procedure.
When the pump is primed, and with sufficient air
supplied, the pump starts when the dispensing
valve is opened and shuts off when it is closed.
5. Set the air pressure to each pump at the lowest
pressure needed to get the desired results.
6
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
Relieve pressure before you check or service any
system equipment.
Problem
Cause
Solution
Pump fails to operate
Inadequate air supply pressure or
restricted air lines
Increase air supply and/or clear
restriction.
Closed or clogged pump valves
Open and/or clean.
Clogged fluid line, hose, valve, or
other accessory
Relieve pressure.
Clear obstruction.
Damaged air motor
Assess damage, and service air
motor.
Exhausted fluid supply
Refill and reprime or flush.
Continuous air exhaust
Erratic pump operation
Worn or damaged air motor
gasket or seal
Assess wear or damage, and service
air motor.
Exhausted fluid supply
Worn pump seals
Refill and reprime or flush.
Replace.
Damaged shovel tube
Damaged check seat
Replace.
Replace pump piston or shovel rod
(or other damaged part).
Errataic or accelerated pump speed Exhausted fluid supply
Fluid too heavy for pump priming
Refill and reprime of flush.
Use inductor or follow plate.
Clear valve; replace seal.
Held open or worn piston valve or
seal
Held open or worn intake valve or
seal.
Clear valve; replace seal.
Pump operates, but output low on up Worn piston seal
Replace.
stroke
Damaged upper check seat
Worn fluid intake seal
Replace pump piston.
Replace.
Pump operates, but output low on
down stroke
Damaged lower check seat
Replace shovel rod.
Pump operates, but output low on
both strokes
Inadequate air supply pressure or
restricted air lines
Increase air supply and/or clear
restriction.
Closed or clogged pump valves
Exhausted fluid supply
Open and/or clean.
Refill fluid supply, and reprime pump.
Clogged fluid line, hose, valve, or
other accessory
Relieve pressure.
Clear obstruction.
Worn seals
Replace.
Replace.
Grease leaking from muffler plates
Worn throat seal
309966J
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Displacement Pump Service
Displacement Pump Service
•
Be sure you have all necessary parts on hand
before you start. If using a repair kit, use all the
parts in the kit for the best results.
10. Check to make sure there is endplay at pinned con-
nections.
When there is endplay at the pinned connection,
you should be able to slightly move from
side-to-side, the connecting rod (57) pinned to the
displacement rod (8) and the piston (52) pinned to
the priming rod (58).
•
Displacement Pump Repair Kit 246920 is available.
Parts included in the kit are marked with a dagger
(†) in the parts drawing and list.
If these connections seem too rigid:
•
•
remove the pin
adjust hole alignment by 1/2 turn in the
direction that aligns the thru holes as close
alignment take the self-aligning feature out
of the design, which could result in damage
to the pump.
Disassembly
1. Flush pump.
2. Relieve pressure, (page 6).
3. Disconnect hoses and remove pump from its
mounting. Clamp the air motor base (5) in a vise.
Fig 1 - 1/2 Turn Too Deep
Fig 2 - 1/2 Turn Too Shallow
Fig 3 - Correct
Does not permit
end play
CAUTION
To avoid damaging the shovel tube, do not use slots
in the tube to tighten or loosen tube.
ti10469a
Incorrect Alignment
4. Use strap wrench to remove shovel tube (67).
5. Unscrew shovel (66) from priming rod (58).
6. Unscrew seal retainer (63) from pump cylinder (59).
Remove o-ring (61) from seal retainer. Inspect all
parts for damage.
ti10479a
Does not permit
end play
7. Use a strap wrench to remove pump cylinder (59)
from the extension tube (64). Remove intake seal
(62) from pump cylinder. Remove gasket seal (60)
from pump cylinder. Inspect all parts for damage.
Permits end play
ti10468a
8. Use a small punch to drive pin (53) out of connect-
ing rod (57) and piston (52) connection. Unless
priming rod (58) is damaged, leave the pin connect-
ing the piston (52) and priming rod (58) assembled.
Correct Alignment
FIG. 3
9. Unscrew piston/priming rod assembly from the con-
necting rod (57). Slide piston seal (54) off piston and
inspect for damage.
11. Clean all parts in a compatible solvent and inspect
them for wear or damage.
8
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Displacement Pump Service
Reassembly
1. Slide piston seal (54) on piston/priming rod (58)
assembly.
2. Screw priming rod (58) assembly onto connecting
rod (57). Align the thru holes as close as possible,
axis-to-axis (FIG. 3). See endplay Note included in
for additional assembly instructions.
3. Generously lubricate all parts of the shaft assembly
with a light, water resistant grease.
4. Replace the gasket seal (60) on the pump cylinder
(59). Screw the pump cylinder onto the extension
tube (64).
5. Slide the intake seal (62) onto the priming rod (58)
flat side down.
6. Replace the o-ring (61) on the seal retainer (63).
Slide the seal retainer over the priming rod (58) and
screw into the pump cylinder. Using the seal
retainer torque the entire cylinder assembly to 44-55
ft-lbs (61-75 N.m).
7. Screw the shovel (66) on the priming rod (58).
Screw the shovel tube (67) on the seal retainer (63).
8. If the ground wire was disconnected before servic-
ing, be sure to reconnect it before you operate the
pump.
309966J
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Displacement Pump Service
1
Using nut (63), torque the pump cylinder (59)
to the extension tube (64) at 45-55 ft-lb
(61-75 N•m).
2
3
62
61
2 Lubricate.
2
Flat side must face retainer (106).
3
57
4
Assemble pin (53) flush or below surface.
2
63
60
5 Large bevel must face piston (52).
6
Lubricate inside diameter.
7 See endplay Note included in Step 10,
Pump Disassembly instructions (page 8)
for additional assembly instructions.
6
2
58 (REF)
64
60
66
1
59
2
5
57 (REF)
54
7
4
53
52
01971
FIG. 4
10
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Air Motor and Throat Service
Air Motor and Throat Service
•
Before you start, be sure you have all necessary
parts on hand. Repair Kit 246919 is available for the
motor. Use all the parts in the kit for the best results.
Parts included in the kit are marked with an asterisk
(*) in the parts drawing and list.
8. Remove the six screws (21) that hold the cylinder
(17) to the base. Carefully pull the cylinder straight
up off the piston (2).
CAUTION
To avoid damaging the cylinder wall, lift the cylinder
straight up off of the piston. Never tilt the cylinder
while you are removing it.
•
Two accessory tools should be used. Order Padded
Pliers, 248198, to grip the trip rod without damaging
its surface. Use Gauge, 15E796 (included in kit), to
ensure the proper clearance between the poppets
and seat of the transfer valve.
Disassembly
9. Use a screwdriver to push down on the trip rod yoke
(22). Always keeping fingers clear of the toggle
assemblies (L), snap the toggles down. Straighten
the lockwires (31) and remove them from the adjust-
ing nuts (30) of the transfer valves. Remove the top
nuts. Unscrew the stems (1) from the grommets (12)
and bottom nuts. Squeeze orange poppets (1) firmly
to check for cracks. See Fig. 5.
1. Flush the pump.
2. Relieve the pressure before you proceed.
3. Disconnect the hoses, remove the pump from its
mounting, and clamp the air motor base (5) in a
vise.
10. Grip the toggle rockers (26) with a pliers. Compress
the springs (27), and swing the toggle assembly (L)
up and away from the piston lugs (M), and remove
the parts. Check to see that the valve actuator (13)
is supported by the spring clips (14), but slides eas-
ily into them. See Fig. 5.
4. Use a strap wrench or pipe wrench on the extension
tube (64) to unscrew it from the base (5). See Fig. 4.
11. Remove the trip rod yoke (22), actuator (13), and
trip rod (11). Check the exhaust valve poppets (16)
for cracks.
5. Pull the extension rod (57) down as far as it will go,
exposing the displacement rod (8).
6. Use a hammer and punch to remove the roll pin (74)
from the displacement rod (8), and unscrew the
extension rod (57) from the displacement rod.
To remove cracked exhaust valve poppets (16),
stretch them out, and cut them with a sharp knife.
CAUTION
12. Remove one of the air motor plates (18 or 20). Pull
the piston (2) up out of the base (5). Remove the
throat packing nut (38) and throat seal (6).
In step 7, do not damage the plated surface of the trip
rod (11). A damaged trip rod could cause erratic air
motor operation. Use the special padded pliers
(248198) to grasp the rod.
7. Manually push on the displacement rod (8) to move
the air motor piston (2) up as far as it will go.
Unscrew the cylinder cap nut (29a or 29b). Pull the
nut up. Grip the trip rod (11) with padded pliers, and
unscrew the nut from the rod. See Fig. 4.
309966J
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Air Motor and Throat Service
11
17
2
5
38
21
6
57
64
74
8
9040
Torque extension tube (64) to the base (5)
at 45 to 55 ft-lb (61 to 75 N•m.
FIG. 5
12
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Air Motor and Throat Service
Reassembly
1. Clean all the parts carefully in a compatible solvent,
and inspect for wear or damage. Use all the repair
kit parts during reassembly, and replace other parts
as necessary.
7. Install the air intake grommets (12), and reassemble
the valve mechanism. Before you install the lock-
wires (31) in the adjusting nuts (30), use the special
gauge, 15E796, to adjust the transfer valve so there
is 0.105 + .010 in. clearance between the poppets
(1) and the seat when it is open. See Fig. 5. Snap
the toggles (25) to the up position. This is essential
for reliable air motor performance.
2. Check the polished surfaces of the piston (2), dis-
placement rod (8), and cylinder (17) wall for
scratches or wear. A scored rod causes premature
throat seal wear and leaking.
8. Reassemble the air motor, and assemble to the dis-
placement pump. Torque the extension tube (64) to
to base (5) at 45 to 55 ft-lb (61 to 75 N•m). Before
you install the air motor plate, tighten the throat
packing nut (38) snugly; do not overtighten it.
3. Lubricate all parts with a light, water–resistant
grease.
4. Install the new throat seal (6), lips facing down.
Screw the packing nut (38) into the base (5).
9. Before you remount the pump, connect an air hose,
and run the pump slowly, at about 40 psi (276 kPa,
2.8 bar), to ensure that it operates smoothly.
5. Slide the displacement rod (8) down through the
throat, and lower the piston (2) into the base (5). Be
sure the o–rings (9, 10, and 24) are in place. See
Fig. 4.
10. Reconnect the ground wire before regular operation
of the pump.
6. Pull the exhaust valve poppets (16) into the valve
actuator (13), and clip off the top part shown with
dotted lines in Fig. 5.
L
2
27
26
25
11
22
3
11
31
30
14
13
16
1
30
M
12
30
1
12
24
30
0.105 in.
(2.7 mm)
2
1
2
04118
04119
1
2
3
Turn wires up.
Push toggles (L) in and then up.
Cut off tops of poppets as indicated by dotted lines
Cutaway View
FIG. 6
309966J
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
Model No. 246909, Series C, Pail Length
Model No. 246780, Series C, 120-pound Drum Length
Model No. 246781, Series C, 400-pound drum length
Model No. 253361, Series C, Pail Length without Handle
* Replacements for these parts are available in Repair Kit 246919 which may be purchased separately.
†Replacements for these parts are available in Repair Kit 246920 which may be purchased separately.
1
See endplay Note included in Step 10, Pump Disassembly instructions (page 8) for additional assembly instructions.
29a
38
29b
6†
†60
9*
28
18
59
10
17
5
†54
31*
30*
21
13
23
22
1
53†
52
5a
25
27
7
16*
†62
61
12*
30*
11
15
60†
20
26
63
19
14
64
57
58
66
*24
2
1*
33
1
53†
8
67
1
56†
8964
14
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Air Motor
Pump
Ref.
No
1*
2
5
5a
6†
7
Qty
.
Ref.
No
52
Qty
.
Part No. Description
248211 VALVE, poppet
Part No. Description
15G098 PISTON
2
1
1
1
1
1
1
1
1
1
2
1
2
2
2
1
1
12
1
6
1
2
1
2
2
2
1
1
1
2
1
1
1
15W205 PISTON, air motor
253999 BASE, air motor (includes 5a)
116343 SCREW, grounding
118355 SEAL, throat, polyurethane
162718 ADAPTER
15C527 ROD, displacement
113347 O-RING, buna-N
53† 119956 PIN, straight
54† 15G116 SEAL, piston
56† 112154 PIN, straight, slotted
57
15C758 ROD, extension (Model 246909
and 253361)
15C541 ROD, extension (Model 246780)
15C542 ROD, extension (Model 246781)
15F296 ROD, shovel
8
1
1
1
1
2
1
1
1
1
9*
10
11
12*
13
14
15
16*
17
18
19
118109 O-RING, buna-N
15C279 ROD, trip
58
59
15C537 CYLINDER, pump
118107 GROMMET, rubber, air intake
15C249 ACTUATOR, valve
15C248 CLIP, spring
118718 SCREW, round head machine
15C267 POPPET, valve, urethane
15C274 CYLINDER, air motor
246782 PLATE, identification; with muffler
100078 SCREW, hex head
60† 192533 SEAL, gasket
61 119955 O-RING
62† 15G096 SEAL, shovel rod
63
64
15F169 CONNECTOR, tube
192682 TUBE, extension (Model 246909
and 253361)
193760 TUBE, extension (Model 246780
193758 TUBE, extension (Model 246781)
192660 SHOVEL
1
1
1
1
20 246783 PLATE, warning; with muffler
66
67
21
22
23
24*
25
26
27
28
101578 SCREW, hex head
15C245 YOKE, rod, trip
15C275 PIN, toggle
118108 O-RING, nitrile rubber
15C277 ARM, toggle
15C276 ROCKER, toggle
118111 SPRING, helical compression
156698 O-RING, buna-N
17A265 TUBE, shovel
†Replacements for these parts are available in
Repair Kit 246920 which may be purchased
separately
29a 15F691 HANDLE NUT, cylinder cap
(Model 246909)
29b 15C278 NUT, cylinder cap
(Models 253361, 246780 and
246781)
1
30*
31*
33
15C246 NUT, adjusting
4
2
1
1
15C247 LOCKWIRE, transfer valve
15C266 GASKET, copper
15C530 NUT, packing
38
Replacement Danger and Warning labels, tags, and
cards are available at no cost.
* Replacements for these parts are available in
Repair Kit 246919 which may be purchased
separately
Two accessory tools are required for air motor and
throat service: padded pliers 248198 and gauge
15E796 (included in repair kit 246919) to ensure
gap is set correctly
309966J
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional Drawings
Dimensional Drawings
Model 246909
pail length
Model 253361
pail length without handle
Model 246781
400 lb drum size
Model 246780
120 lb drum size
grounding screw
3/8 npt(f)
air inlet
grounding
screw
grounding screw
3/8 npt(f)
air inlet
3/8 npt(f)
air inlet
1/4 npt(f)
fluid outlet
1/4 npt(f)
fluid outlet
1/4 npt(f)
fluid outlet
17.5 in.
(445 mm)
26.7 in.
33.6 in.
(678 mm)
(853 mm)
Overall length:
30.2 in (768 mm)
Overall length:
37.6 in (955 mm)
Overall length:
44.5 in (1130 mm)
Mounting Hole Layout
Order gasket 15R881 for sealed tank/drum mounting.
Pump Base
2.518” (6.4 cm) dia.
4.250” (10.8 cm) bolt circle
0.281” (7.1 mm) diameter clearance holes
4.250” (10.8 cm) bolt circle
0.266” (6.7 mm) diameter clearance holes
16
309966J
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Maximum fluid working pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8400 psi (58 MPa, 580 bar)
Maximum air inlet pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 psi (1.0 MPa, 10 bar)
Ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50:1
Pump cycles per lb (.45 kg) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130
Maximum recommended pump speed. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 cycles/min
Recommended pump speed for continuous operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 cycles/min
Maximum delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 lb/min (.25 kg/min) at 60 cycles/min
Stroke length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 in. (50.8 mm)
Maximum pump operating temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130°F (54°C)
Air inlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8 npt(f)
Fluid outlet size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 npt(f)
Wetted parts. . . carbon steel; zinc plating; brass; polyurethane; ultra-high molecular weight polyethylene; Buna-N
Sound pressure level (measured 1 meter from unit) . . . . . . . . . . . . . . . . . . . . . . . . 77.8 dB(A) @ 140 psi, 100 cpm
Sound power level (tested in accordance with ISO 9614-2 . . . . . . . . . . . . . . . . . . . 85.6 dB(A) @ 140 psi, 100 cpm
Approximate weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 lb (6.8 kg)
All brand names or marks are used for identification purposes and are trademarks of their respective owners.
309966J
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written
recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 309966
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2006, Graco Inc. is registered to ISO 9001
Revised April 2015
Download from Www.Somanuals.com. All Manuals Search And Download.
|