Dump Valve and Third  
Purge Valve Kits  
312786G  
EN  
®
For use with ProMix 2KS Electronic Proportioners. For professional use only.  
See page 2 for kit part numbers and maximum working pressure.  
15V821 Dump Valve Kit  
for Wall Panel  
Important Safety Instructions  
Read all warnings and instructions in this manual. For complete  
warnings and instructions see your proportioning system manual.  
Hazard symbols refer to specific procedure risks. Save all instruc-  
tions.  
15V354 Third Flush Valve Kit  
for Wall Panel, shown on  
Fluid Mix Manifold  
TI12743a  
TI12954a  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Installation  
15V821 Dump Valve Kit for Wall Panel  
NOTE: These instructions show this kit being installed  
5. Install the dump valve assembly (includes 1, 2, 4,  
on the A side. It may also be installed on the B side.  
and 11) in a slot of the flange (F) at the back of the  
wall panel. Secure with the nut (8).  
6. Install the elbow (6) in the open port of the dump  
valve adapter (2). Connect a 1/4 npsm(f) hose (12)  
between the elbow (6) and nipple (19).  
1. Shut off the fluid supply to the dose valve (V) at the  
front of the wall panel.  
2. Actuate the dose valve to relieve fluid pressure in  
the valve.  
7. Shut off all power to the fluid panel. Open the fluid  
panel. See the Wall Panel detail in FIG. 2. Install the  
solenoid (9) at the correct position (Dump Valve A  
or Dump Valve B) on the solenoid manifold. Con-  
nect the solenoid wires to the fluid panel control  
board as shown in FIG. 3. Also see the System  
3. Relieve fluid pressure upstream and downstream of  
the dose valve. See your ProMix 2KS Operation  
Manual.  
4. See FIG. 1. Remove the plug from the dose valve  
adapter. Install the street elbow (18) in this port.  
Install the nipple (19) in the elbow.  
8. Connect the tubing (7) between the solenoid mani-  
fold and the tube fitting (T) on the dump valve (1).  
At Front of Wall Panel  
At Back of Wall Panel  
A SIDE  
B SIDE  
1
12  
V
12  
T
6
18  
F
TI12744a  
TI12743a  
8
2
19  
FIG. 1: 15V821 Kit Installation  
312786G  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
Wall Panel  
RoboMix Panel  
Dump  
Valve B  
Dump  
Valve A  
3rd Flush  
Valve  
TI12655a  
Dump  
Valve B  
Dump  
Valve A  
GFB2  
3rd Flush  
Valve  
GFB1  
TI13116a  
FIG. 2: Solenoid Manifolds  
J15-1 J15-2 J15-5 J15-6 J8-1 J8-2 J8-3 J8-4 J8-5  
J8-6  
Auto Dump  
Auto Dump  
3rd Purge Valve Dump Valve A  
Dump Valve B Valve A (GFB1) Valve B (GFB2)  
Wire Color  
J15-1  
J15-2  
J15-5  
J15-6  
J8-5  
J8-6  
J8-3  
J8-4  
J8-1  
J8-2  
Red  
Black  
FIG. 3: 255765 Fluid Panel Control Board, Detail View of Solenoid Connections  
4
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
15V354 Third Flush Valve Kit for Wall Panel  
7. Connect the tubing (13, 14) between the solenoid  
manifold and the tube fittings (T) on the flush valve  
(2). See System Pneumatic Schematic, page 10.  
1. Shut off the air and fluid supply to the ProMix 2KS.  
2. Relieve pressure. See your ProMix 2KS Operation  
Manual.  
3. See FIG. 4. Remove the air flush valve (AFV) from  
the fluid mix manifold (FM) and set it aside.  
6
1
8
FM  
TI12956a  
FIG. 5: Install Double Valve Mounting Block  
AFV  
TI12955a  
1
FIG. 4: Disconnect Air Flush Valve  
AFV  
7
4. See FIG. 5. Install the o-ring (6), double valve  
mounting block (1), and screws (8).  
2
5. See FIG. 6. Install the air flush valve (AFV) on the  
double valve block (1). Assemble the third flush  
valve kit parts (2, 3, 4, 6, 9, 10, 11) as shown on  
page 15. Install on the mounting block using the  
screws (7). See FIG. 6.  
TI12957a  
FIG. 6: Install Third Flush Valve  
6. Shut off all power to the fluid panel. Open the fluid  
panel. See the Wall Panel detail in FIG. 2. Install the  
solenoid (12) and two tube connectors (15) at the  
correct position (3rd Flush Valve) on the solenoid  
manifold. Connect the solenoid wires to the fluid  
panel control board as shown in FIG. 3.  
312786G  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
15V822 Dump Valve Kit for RoboMix  
NOTE: These instructions show this kit being installed  
on the B side. It may also be installed on the A side.  
1. See FIG. 7. Shut off the fluid supply to the dose  
valve (V) in the RoboMix.  
2. Actuate the dose valve to relieve fluid pressure in  
the valve.  
3. Relieve fluid pressure upstream and downstream of  
the dose valve. See your ProMix 2KS Operation  
Manual.  
4. Remove the plug from the dose valve adapter.  
Apply thread sealant and install the elbow (8) in this  
port.  
5. Install the valve adapter (3) in the RoboMix. Secure  
with four screws (11). Apply thread sealant and  
install the nipple (9) through the back of the Robo-  
Mix and into the adapter. Install the swivel (6) in the  
opposite side of the adapter.  
6. Install the seat (2), o-ring (10), and dump valve (1)  
in the adapter (3).  
7. Connect the hose (5) between the swivel (6) and  
elbow (8).  
8. Shut off all power to the fluid panel. Open the fluid  
panel. See the RoboMix Panel detail in FIG. 2.  
Install the solenoid (4) at the correct position (Dump  
Valve A or Dump Valve B) on the solenoid manifold.  
Connect the solenoid wires to the fluid panel control  
board as shown in FIG. 3. Also see the System  
9. Connect the tubing (13) between the solenoid mani-  
fold and the tube fitting (T) on the dump valve (1).  
6
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation  
1
T
10  
2
3
TI12655a  
6
Dump  
Valve B  
Dump  
Valve A  
5
V
8
4
11  
9
TI13047a  
TI13045a  
FIG. 7: 15V822 Kit Installation  
15V202 Third Flush Valve Kit for RoboMix  
7. Install the o-ring (2), seat (1), o-ring (6), and third  
flush valve (5) in the adapter (3).  
1. Shut off the air and fluid supply to the ProMix 2KS.  
2. Relieve pressure. See your ProMix 2KS Operation  
Manual.  
8. See FIG. 8. Shut off all power to the fluid panel.  
Open the fluid panel. Install the solenoid (8) in the  
third flush valve position on the solenoid manifold.  
Install the tube connector (9). Connect the solenoid  
wires to the fluid panel control board as shown in  
FIG. 3. Also see the System Electrical Schematic  
on page 13.  
3. See FIG. 8. Remove the plug (A) from the air flush  
valve (AFV). Install an o-ring (6) in this port.  
4. Install the third flush valve adapter (3) in the Robo-  
Mix. Ensure that the o-ring (6) remains in place to  
seal between the adapter and the air flush valve  
adapter.  
9. Connect the tubing (13) between the solenoid mani-  
fold and the tube fitting (T) on the third flush valve  
(5). See System Pneumatic Schematic, page 10.  
5. Secure the adapter (3) to the air flush valve adapter  
with four screws (10) inserted through the side wall  
of the RoboMix. Torque to 70 in-lb (8 N•m).  
10. Connect the third flush fluid supply line to the check  
valve (4).  
6. Apply thread sealant and install the check valve (4)  
through the back of the RoboMix and into the third  
flush valve adapter (3).  
312786G  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
9
5
T
6
1
3
6
TI12655a  
2
8
4
10  
TI13046a  
TI13047a  
FIG. 8: 15V202 Kit Installation  
15X247 Auto Dump Valve Kit  
6. Connect a 1/4 npsm(f) dump hose (not supplied) to  
the 1/4 npsm(m) threaded stud at the bottom of the  
adapter (2). When the gun closes, the dump valve  
opens and fluid is dumped through the stud.  
1. Close the component A and component B shutoff  
valves on the fluid manifold.  
2. Trigger the gun to relieve fluid pressure downstream  
of the fluid manifold.  
7. Shut off all power to the fluid panel. Open the fluid  
panel. See the Wall Panel detail in FIG. 9. Install the  
solenoid (5) at the correct position (GFB1 or GFB2)  
on the solenoid manifold. Connect the solenoid  
wires to J8 on the fluid panel control board as  
shown in FIG. 3. Also see the System Electrical  
3. See FIG. 9. Install the small o-ring (3), seat retainer  
(6), large o-ring (7), and dump valve (1) in the valve  
adapter (2).  
4. Install the valve adapter (2) in the mixed material  
line, downstream of the static mixer and as close to  
the gun as possible.  
8. Install the tube connector (9) in the solenoid mani-  
fold. Connect the tubing (4) between the connector  
and the tube fitting (T) on the dump valve (1). See  
NOTE: Connect the static mixer to one 1/4 npt port of  
the valve adapter.  
5. Install the nipple (8) in the other port of the adapter  
(2). Connect the gun line to this nipple.  
8
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
1
T
7
6
3
8
2
J8 (see FIG. 3  
for details)  
9
4
5
TI14283b  
TI13116a  
Wall Panel  
FIG. 9: 15X247 Kit Installation  
312786G  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Schematic Diagrams  
Schematic Diagrams  
System Pneumatic Schematic  
COLOR  
VALVE  
STACKS  
COLOR  
CHANGE  
CONTROL  
AIR EXHAUST MUFFLER  
MANIFOLD  
COLOR 1  
COLOR 2  
COLOR 3  
12 VDC  
COLOR 4  
COLOR 5  
COLOR 6  
COLOR 7  
DOSE A  
VALVE  
OSE  
CL  
4-WAY SOLENOID  
A
A
B
B
5/32 TUBE  
OPEN  
COLOR 8  
12 VDC  
COLOR SOLVENT  
COLOR 9  
DOSE B  
VALVE  
OSE  
CL  
4-WAY SOLENOID  
COLOR 10  
COLOR 11  
COLOR 12  
CATALYST 1  
CATALYST 2  
CATALYST 3  
CATALYST 4  
CATALYST SOLVENT  
5/32 TUBE  
OPEN  
12 VDC  
PURGE A  
VALVE  
OSE  
05  
CL  
4-WAY SOLENOID  
A
B
5/32 TUBE  
OPEN  
3/8 AIR FILTER  
MANUAL DRAIN  
5 MICRON  
12 VDC  
WALL MOUNT ONLY  
PURGE B  
VALVE  
COLOR 13  
COLOR 14  
COLOR 15  
COLOR 16  
COLOR 17  
COLOR 18  
COLOR 19  
COLOR 20  
COLOR 21  
COLOR 22  
COLOR 23  
COLOR 24  
COLOR 25  
COLOR 26  
COLOR 27  
COLOR 28  
COLOR 29  
COLOR 30  
OSE  
CL  
4-WAY SOLENOID  
A
A
B
B
5/32 TUBE  
OPEN  
AIR INPUT  
12 VDC  
PURGE C  
VALVE  
OSE  
CL  
(OPTIONAL)  
4-WAY SOLENOID  
AIR EXHAUST MUFFLER  
12 VDC  
5/32 TUBE  
OPEN  
DUMP A  
VALVE  
(OPTIONAL)  
3-WAY SOLENOID  
5/32 TUBE  
OPEN  
A
A
AIR INPUT  
12 VDC  
DUMP B  
VALVE  
(OPTIONAL)  
3-WAY SOLENOID  
5/32 TUBE  
OPEN  
MAC  
36 SERIES SOLENOID VALVES  
12 VDC  
GFB 1  
VALVE  
3-WAY SOLENOID  
(OPTIONAL)  
5/32 TUBE  
OPEN  
A
A
12 VDC  
GFB 2  
VALVE  
(OPTIONAL)  
3-WAY SOLENOID  
5/32 TUBE  
OPEN  
MANIFOLD  
10  
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Schematic Diagrams  
Tubing Schematic  
B3  
13  
B1  
A2  
A6  
13  
GFB1-P  
GFB2-P  
B7  
B5  
AT  
DB  
DA  
A4  
B7  
A8  
TI13857a  
TI13858a  
B1  
B3  
B5  
GFB1-C GFB2-C  
GFB1-A  
GFB2-A  
TI13862a  
A2  
A4  
A6  
A8  
DA DB  
GFB1-P  
GFB1-A  
ATOM-1  
ATOM-2  
GFB1-C  
GFB1-S  
GFB1-S  
GFB2-S  
GFB1  
GFB2  
GFB2-P  
GFB2-A  
GFB2-C  
GFB2-S  
ATOM-2  
ATOM-1  
TI13861a  
TI13860a  
TI13863a  
312786G  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Schematic Diagrams  
Table 1: Tubing Chart  
Ending  
Tube OD  
in. (mm)  
Color  
Description  
Starting Point  
Point  
Tube Ref. No.  
Green  
Green  
Green  
Green  
Green  
Green  
Dose A On  
Dose B On  
Purge A On  
Purge B On  
Dump A  
A2  
A4  
A6  
A8  
DA  
DB  
A2  
A4  
A6  
A8  
DA  
DB  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
336  
336  
336  
336  
Included in optional  
Dump Valve Kit  
15V821  
Dump B  
Red  
Dose A Off  
B1  
B3  
B5  
B7  
13  
B1  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
1/4 (6)  
337  
337  
337  
337  
334  
Red  
Dose B Off  
B3  
Red  
Purge A Off  
B5  
Red  
Purge B Off  
B7  
Natural  
Natural  
Solenoid Air Supply  
13  
Gun Flush Box 1 Pressure GFB1-A  
Switch Signal  
GFB1-A  
5/32 (4)  
Natural  
Natural  
Natural  
Natural  
Natural  
Natural  
Natural  
Gun Flush Box 2 Pressure GFB2-A  
Switch Air  
GFB2-A  
GFB1-C  
GFB2-C  
GFB1-P  
GFB2-P  
GFB1-S  
GFB2-S  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
5/32 (4)  
Gun Flush Box 1 Trigger  
Air  
GFB1-C  
GFB2-C  
GFB1-P  
GFB2-P  
GFB1-S  
GFB2-S  
Gun Flush Box 2 Trigger  
Air  
Included in optional  
Gun Flush Box Kit  
15V826  
Gun Flush Box 1 Supply  
Air  
Gun Flush Box 2 Supply  
Air  
Gun Flush Box 1 Safety  
Interlock  
Gun Flush Box 2 Safety  
Interlock  
Natural  
Natural  
Gun 1 Atomizing Air  
Gun 2 Atomizing Air  
ATOM-1  
ATOM-2  
ATOM-1  
ATOM-2  
1/4 (6)  
1/4 (6)  
User supplied. Con-  
nects air flow switch to  
gun air shutoff valve.  
Natural  
Purge Air Supply  
Use as a separate line  
connected directly to the  
main shop air line. Do  
not connect to the unit’s  
main air supply or to the  
air manifold (335).  
AT  
1/4 (6)  
338  
12  
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Schematic Diagrams  
System Electrical Schematic  
Hazardous Area  
HAZARDOUS AREA  
3X CABLE  
FLUID PANEL CONTROL BOX  
FLUID  
1
2
3
4
5
6
PWR (RED)  
FLOW METER A  
COM (BLACK)  
SIG (WHITE)  
SHIELD/GRN  
PWR (RED)  
PANEL  
J3  
CONTROL  
BOARD  
I.S. METERS  
FLOW METER B  
COM (BLACK)  
SIG (WHITE)  
SHIELD/GRN  
PWR (RED)  
1
2
3
4
5
6
FLOW METER SOLVENT  
COM (BLACK)  
SIG (WHITE)  
SHIELD/GRN  
J2  
J4  
J12  
TECNO  
SIG (RED)  
1
2
J1  
V/P  
COM (BLK)  
1
2
3
4
5
FLOW  
CONTROL  
BOARD  
V/P ANALOG OUT (WHT)  
GROUND  
TERMINAL  
PRESS. (GRN)  
+12 V (RED)  
GND (BLK)  
1
UNUSED  
UNUSED  
UNUSED  
UNUSED  
UNUSED  
UNUSED  
2
3
4
5
6
+ PRESSURE (GRN)  
COM (RED)  
EX+ (WHT)  
- PRESSURE (BLK)  
SHIELD (BARE)  
FLUID  
PRESS.  
SENS.  
CHASSIS (BARE)  
1
2
3
4
5
J10  
J13  
(10')/  
(40')  
1
2
3
+12VDC I/S  
COM  
SHIELD  
1
2
3
4
5
6
J5  
MH2  
J7/J11  
1
4
5
2
3
COLOR  
BOARD 1  
(COLORS  
1 THRU 12,  
CATALYST  
1 THRU 4)  
6' STD.  
(3'-100' OPTIONS)  
3
2
5
4
1
GRD (BLK)  
+12VDC (RED)  
SHIELD (BARE)  
CAN H (WHT)  
CAN L (BLU)  
J11  
J7  
MANIFOLD  
MANIFOLD  
6
5
4
3
2
1
COM  
+12VDC  
COM  
1
2
3
4
5
6
CLR 9  
+12VDC  
CLR 8  
COM  
+12VDC  
COM  
CLR 10  
CLR 11  
CLR 7  
CLR 6  
+12VDC  
COM  
J8  
J9  
50' STD.  
+12VDC  
COM  
+12VDC  
BOOTH  
CONTROL  
BOARD  
3
3
2
5
4
1
GRD (BLK)  
2
5
4
1
+12VDC (RED)  
SHIELD (BARE)  
CAN H (WHT)  
CAN L (BLU)  
1
2
3
4
5
6
+12VDC  
COM  
6
5
4
3
2
1
COM  
+12VDC  
COM  
CLR 5  
CLR 4  
CLR 3  
CLR 12  
CAT 4  
CAT 3  
+12VDC  
COM  
J16  
J15  
+12VDC  
COM  
+12VDC  
COM  
+12VDC  
COM  
+12VDC  
COM  
6
5
4
3
2
1
1
2
3
4
5
6
+12VDC  
COM  
CAT 2  
CLR 2  
+12VDC  
COM  
CAT 1  
MANIFOLD  
CLR 1  
J14  
J10  
+12VDC  
COM  
BLACK  
RED  
6
+12VDC  
COM  
SOL CAT  
DUMP B  
GFB #1  
GFB #2  
SOL CLR  
+12VDC  
5
4
3
2
1
BLACK  
RED  
1
4
5
5
2
2
3
3
J8  
J7/J11  
J7/J11  
BLACK  
RED  
6' STD.  
BLACK  
RED  
6
5
4
3
2
1
1
4
DUMP A  
NOT USED  
PURGE C  
COLOR  
BOARD 2  
(COLORS  
BLACK  
RED  
J15  
MANIFOLD  
13 THRU 30)  
BLACK  
RED  
MANIFOLD  
BLACK  
RED  
6
5
4
3
2
1
MANIFOLD  
PURGE B  
PURGE A  
NOT USED  
1
2
3
4
5
6
+12VDC  
COM  
6
5
4
3
2
1
COM  
+12VDC  
COM  
CLR 21  
CLR 20  
CLR 19  
CLR 22  
CLR 23  
CLR 24  
BLACK  
RED  
+12VDC  
COM  
J14  
J9  
J8  
J9  
+12VDC  
COM  
+12VDC  
COM  
BLACK  
RED  
+12VDC  
1
2
3
4
5
6
+12VDC  
COM  
CLR 18  
CLR 17  
CLR 16  
6
5
4
3
2
1
COM  
+12VDC  
COM  
6
5
4
3
2
1
BLACK  
RED  
CLR 25  
CLR 26  
CLR 27  
NOT USED  
DOSE B  
+12VDC  
COM  
J15  
J14  
J16  
BLACK  
RED  
+12VDC  
COM  
+12VDC  
COM  
+12VDC  
BLACK  
RED  
DOSE A  
1
2
3
4
5
6
+12VDC  
COM  
COM  
+12VDC  
COM  
6
5
4
3
2
1
CLR 15  
CLR 14  
CLR 13  
CLR 28  
CLR 29  
CLR 30  
+12VDC  
COM  
1
SIG  
J10  
+12VDC  
COM  
AIR FLOW SWITCH 1  
2
COM  
SIG  
+12VDC  
COM  
+12VDC  
3
AIR FLOW SWITCH 2  
4
COM  
SIG  
5
SOLVENT FLOW SWITCH  
GFB 1 PRESSURE SWITCH  
GFB 2 PRESSURE SWITCH  
6
COM  
SIG  
FO OUT  
(BLU)  
J1  
J4  
J6  
7
8
COM  
SIG  
9
FO IN  
(BLK)  
10  
COM  
312786G  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
Parts  
15V821 Dump Valve Kit for Wall Panel  
18  
1*  
19  
*14  
*11  
*4  
A B  
12  
*2  
15  
6
13  
7
9
8
TI13116a  
TI12742b  
Ref.  
No. Part No. Description  
Ref.  
No. Part No. Description  
Qty  
Qty  
12  
13  
206966 HOSE; 1-1/2 ft (0.46 m)  
111328 CONNECTOR; 10-32 x 5/32 in. (4  
mm) OD tube  
O-RING; ptfe  
101970 PLUG  
1
1
1*  
24W310 VALVE, dispense; includes 14; see  
manual 312782  
15T717 ADAPTER, dump valve  
111457 O-RING; ptfe  
114342 ELBOW; 1/4 npt (mbe)  
1
2*  
4*†  
6
1
1
1
1
14*† n/a  
1
1
1
1
15  
18  
19  
166866 ELBOW, street; 1/4 npt (m x f)  
C20482 NIPPLE; 1/4 npt  
7
n/a  
TUBE; nylon; 5/32 in. (4 mm) OD;  
2 ft (0.61 m)  
8*  
9
n/a  
NUT, hex; 9/16-18  
1
1
1
*
Parts included in 16A079 Dump Valve Replacement  
Kit (purchase separately).  
121324 VALVE, solenoid, dump valve  
11*† n/a  
SEAT, dump valve; sst  
Order Kit 16A560 to replace a single seat. The kit  
includes a seat (11) and o-rings (4 and 14).  
NOTE: The standard valve seat (11) is SST. To install a  
carbide seat, order Kit 24U054. The kit includes a single  
carbide seat and o-rings 4 and 14.  
Parts labeled n/a are not available separately.  
14  
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
15V354 Third Flush Valve Kit for Wall Panel  
6
8
‡11  
3
7
5
1
TI12953a  
2
‡4  
‡6  
9
10  
12  
15  
TI12652a  
Ref.  
No. Part No. Description  
11‡ n/a SEAT, valve  
Ref.  
Qty  
No. Part No. Description  
1
2
Qty  
1
1
15U673 BLOCK, double valve mount  
15X303 VALVE, dispense; includes item 4;  
see manual 312782  
1
1
12  
13  
121374 VALVE, solenoid, 4-way  
n/a  
TUBE; nylon; 5/32 in. (4 mm) OD; 3  
1
1
2
ft (0.9 m); green  
TUBE; nylon; 5/32 in. (4 mm) OD; 3  
ft (0.9 m); red  
3
4‡  
5
6‡  
7
15T600 ADAPTER, valve  
1
2
3
5
2
14  
15  
n/a  
n/a  
O-RING; ptfe  
101970 PLUG, pipe; 1/4 npt  
109450 O-RING; ptfe  
114263 CONNECTOR; 1/8 npt(m) x 5/32 in.  
(4 mm) OD tube  
n/a  
SCREW, cap, socket-hd; 5/16-24 x  
3/4 in. (19 mm)  
8
109031 SCREW, cap, socket-hd; 5/16-24 x  
1 in. (25 mm)  
2
Parts included in Valve Seat Kit 24A861 (purchase  
separately).  
9
10  
166866 ELBOW, street; 1/4 npt (m x f)  
501867 VALVE, check  
1
1
Parts labeled n/a are not available separately.  
312786G  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
15V822 Dump Valve Kit for RoboMix  
1
TI12655a  
10  
Dump  
Valve B  
Dump  
Valve A  
2
3
6
5
4
8
11  
TI13047a  
9
TI13045a  
Ref.  
No. Part No. Description  
Ref.  
No. Part No. Description  
Qty  
Qty  
11  
12  
13  
C19979 SCREW, cap, socket-hd; 10-24 x  
3/8 in. (10 mm)  
111328 CONNECTOR; 10-32 x 5/32 in. (4  
mm) OD tube  
4
1
15X304 VALVE, dispense; includes item 10;  
see manual 312782  
1
1
1
2
3
4
5
15V888 RETAINER, seat, RoboMix  
15U713 VALVE, adapter; RoboMix  
121795 VALVE, solenoid, 4-way  
15U720 HOSE; 1/4 npt (mbe); 15-1/2 in.  
(394 mm); ptfe  
1
1
1
1
n/a  
TUBE; nylon; 5/32 in. (4 mm) OD; 3  
ft (0.9 m); green  
14  
15  
16  
114342 ELBOW; 1/4 npt (mbe)  
104644 PLUG, screw  
104640 GASKET; buna-N  
1
1
1
6
8
9
10  
114339 UNION, swivel; 1/4 npt  
114446 ELBOW; 1/4 npt(m) x 1/4 npsm(f)  
166421 NIPPLE; 1/4 npt  
1
1
1
1
n/a  
O-RING; ptfe  
Parts labeled n/a are not available separately.  
16  
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
15V202 Third Flush Valve Kit for RoboMix  
9
5
6
3
1
2
TI12655a  
8
4
10  
TI13046a  
TI13047a  
Ref.  
No. Part No. Description  
Qty  
1
2
3
4
5
15V888 RETAINER, seat, RoboMix  
109450 O-RING; ptfe  
15U715 VALVE, adapter; RoboMix  
501867 VALVE, check  
15X304 VALVE, dispense; includes item 6;  
see manual 312782  
1
1
1
1
1
6
8
9
n/a  
O-RING; ptfe  
2
1
1
121795 VALVE, solenoid, 4-way  
111328 CONNECTOR; 10-32 x 5/32 in. (4  
mm) OD tube  
10  
13  
110420 SCREW, cap, socket-hd; 10-24 x  
1-1/2 in. (38 mm)  
4
1
n/a  
TUBE; nylon; 5/32 in. (4 mm) OD; 2  
ft (0.61 m); green  
Parts labeled n/a are not available separately.  
312786G  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Parts  
15X247 Auto Dump Valve Kit  
1
7
6
3
8
2
9
4
5
TI13116a  
TI14283a  
Ref.  
No. Part No. Description  
Qty  
1
2
3†  
4
5
6†  
7†  
8
24W310 VALVE, dispense; includes 7 ; see manual 312782  
15T717 ADAPTER, dump valve  
1
1
1
1
1
1
1
1
1
111457 O-RING; ptfe  
n/a  
TUBE; nylon; 5/32 in. (4 mm) OD; 5 ft (1.52 m)  
121324 VALVE, solenoid, dump valve  
n/a  
n/a  
SEAT, dump valve; sst  
O-RING; ptfe  
C20482 NIPPLE; 1/4 npt  
111328 CONNECTOR; 10-32 x 5/32 in. (4 mm) OD tube  
9
Order Kit 16A560 to replace a single seat. The kit  
includes a seat (6) and o-rings (3 and 7).  
NOTE: The standard valve seat (6) is SST. To install a  
carbide seat, order Kit 24U054. The kit includes a single  
carbide seat and o-rings 3 and 7.  
Parts labeled n/a are not available separately.  
18  
312786G  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Notes  
Notes  
312786G  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Graco Standard Warranty  
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in  
material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty  
published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by  
Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written  
recommendations.  
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty  
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of  
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with  
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or  
maintenance of structures, accessories, equipment or materials not supplied by Graco.  
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of  
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned  
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs  
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.  
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT  
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.  
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy  
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or  
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.  
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT  
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to  
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these  
warranties.  
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or  
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the  
negligence of Graco, or otherwise.  
FOR GRACO CANADA CUSTOMERS  
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,  
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la  
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite  
de ou en rapport, directement ou indirectement, avec les procédures concernées.  
Graco Information  
For the latest information about Graco products, visit www.graco.com.  
For patent information, see www.graco.com/patents.  
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.  
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505  
All written and visual data contained in this document reflects the latest product information available at the time of publication.  
Graco reserves the right to make changes at any time without notice.  
312786  
Graco Headquarters: Minneapolis  
International Offices: Belgium, China, Japan, Korea  
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS, MN 55440-1441 • USA  
Copyright 2008, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.  
Revision G, August 2014  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grindmaster Coffeemaker 67710 User Manual
Haier Flat Panel Television HL26K User Manual
Haier Washer HWM90 96A User Manual
Harbor Freight Tools Battery Charger 91129 User Manual
Hasbro Robotics 69173 User Manual
Hauppauge TV Receiver WinTV USB User Manual
Havis Shields Automobile Accessories P MFK 5 User Manual
Honeywell Yard Vacuum CM67 User Manual
Hypertec Laptop Flextop vsn2 User Manual
IBM Laptop 4347 User Manual