Honeywell Yard Vacuum CM67 User Manual

CM67  
CHRONOTHERM  
PRODUCT SPECIFICATION SHEET  
The CM67 Chronotherm is designed to provide automatic  
time and temperature control of heating or cooling systems  
in villas and apartments. It can be used as part of a system  
in conjunction with combi boilers, oil- burners and gas fired  
boilers, circulation pumps, thermal actuators, zone valves  
and electric heat systems (<8A).  
The CM67 is designed with the installer in mind and includes  
a moulded backplate with trunking guides and wiring  
breakouts to make installation quick and easy.  
The CM67 display, buttons and slider layout are based on  
the same simple programming philosophy used on the  
acclaimed CM51 product. The unit is ideal for consumers  
who want reliable precise temperature control from a simple  
to program easy to use product.  
FEATURES  
Attractive slim styling makes it ideal for location in  
Surface or wallbox mounting options, trunking  
any home.  
guides and wiring breakouts simplify installation.  
7-day program  
6 daily independent time and temperature level  
changes let you set 6 time and temperatures pairs to  
suit your life style.  
OFF position on the slider has an integral fixed frost  
protection setting at minimum of 5°C (installer  
adjustable) so that pipes in the house will never  
freeze in winter.  
Installer Set-Up Mode allows extra functions to be  
set at the discretion of the installer to match the  
consumers applications :  
Temporary programmed temperature override to  
temporarily override the programmed temperature  
till the next switch point.  
Optimisation  
Party button to temporarily maintain (or adjust)  
the current temperature for 1-23 hours.  
Pump Exercise  
Upper / Lower Setpoint Limit Adjust  
Temperature offset  
Minimum ON time  
Cycle rate  
Day Off button copies Sunday’s program into  
tomorrow or today to allow a rest day program  
without having to re-program the CM67.  
Holiday button provides energy savings by  
reducing the temperature for 1 to 99 days when  
people are on holiday, returning to normal operation  
(AUTO or MANUAL) on the day of return.  
Heat / Cool Operation  
Proportional Band Width  
EEPROM memory holds the user program  
CM67 has provision for add-on modules to allow the  
installer to sell additional features during or after the  
first CM67 installation, giving the installer an  
additional sale.  
indefinitely.  
Telephone Interface (optional) can be fitted to the  
CM67 to allow switching between programmed mode  
(slider position) and fixed set-point of 21 oC.  
Outside Temperature Sensor accessory (optional)  
can be fitted to the CM67 to display the external  
temperature.  
24...230V 8A resistive, 3A inductive SPDT relay  
provides compatibility with most domestic central  
heating systems without stocking many different  
models.  
Remote Temperature Sensor (optional) can be fitted  
to the CM67 to control the temperature from another  
room.  
EN0R 8498 R2 11/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CM67 CHRONOTHERM  
INSTALLER SET-UP  
To enter the installer set-up mode :  
a) Set the program slider to OFF.  
b) Press and hold Info i button and press PROG 3,4  
together.  
c) The unit will display the first parameter of the installer  
parameter group category 1 (from n.1 to n.5).  
d) Press TEMP  
or  
to change factory setting. The  
display will flash indicating that a change has been  
made.  
e) Press INFO i button to confirm the change. The display  
will stop flashing.  
f) Press  
+ or - to go to next parameter.  
Abbreviated Set-Up Description  
g) Press PROG 2 button to go to Installer parameter group  
e.g. OP = Optimisation  
category 2 (from parameter n.6 to parameter n.16).  
h) To exit installer mode move the slider in MAN or AUTO  
Installer Set-up Number  
position.  
(Press  
+ or - to change)  
e.g. 1 = Optimisation  
Installer Set-Up Mode  
1
Selected  
Factory Setting or New Choice  
In Installer set up we can :  
Press TEMP L or Mto change  
e.g. O = Optimisation disabled  
1 = Optimisation enabled  
Set-up specific applications  
Enable special features  
Establish support for Optional Accessories  
Specific Applications  
Setting  
Minimum  
What do you need to change ?  
Note :  
a. To change Cycle/Hour, please go to parameter n. 9 in the  
installer set-up mode.  
Cycle/  
Hour  
ON time  
(in minutes)  
b. To change Minimum ON Time, please go to parameter n. 2 in  
the installer set-up mode.  
Heating  
Gas Boilers  
(<30KW)  
6
3
1
4
No action required  
Oil Boiler  
1. Set Minimum ON Time to 4 minutes.  
2. Set Cycle/Hour to 3.  
Thermal  
Actuator  
12  
1
Set Cycle/Hour to 12.  
Zone valve  
6
1
1
No action required.  
Electric heating  
(for applications  
<8A)  
12  
1. Configure the Chronotherm for electric heating (set parameter  
n.7 in the installer set up mode to 1).  
2. Set Cycle/Hour to 12.  
1. For cooling application only, set the Chronotherm to cooling  
(set parameter n.6 in the installer set-up mode to 0)  
2. For heat/ cool application, set the Chronotherm accordingly to  
required mode of operation  
Air  
conditioning  
winter = heating  
summer = cooling  
by changing parameter n.6 in the installer set-up mode. Explain to  
the end-user how to implement the change-over.  
Heat Pump/  
Air conditioner  
3
4
1. Set Minimum ON Time to 4 minutes .  
2. Set Cycle/Hour to 3.  
3
EN0R 8498 R2 11/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CM67 CHRONOTHERM  
Special Features  
Description  
What to do if we wish this  
feature  
Optimisation (Variable  
Start Time)  
Adaptive Intelligence  
recovery TM  
The Chronotherm will adjust the start time in the  
morning/ afternoon so the desired temperature is  
reached by the start of the program period e.g. Time  
7:00, Temp 21 oC. The Chronotherm will monitor the  
accuracy of the start up and use this information to  
modify the calculation for the following day by  
changing the ramp rate (initial 3 K/hr) .The system will  
restrict the start time to a max of 3 hours.  
Set parameter. 1 in the installer set-  
up mode to 1.  
Optimisation will not work in cooling mode.  
AM-PM/ 24hr Display  
Pump exercise  
Change display format (default 24hr)  
Set parameter n.3 in the installer set -  
up mode to 1.  
When enabled the Pump Exercise will switch the relay  
on for 1 minute at 12:00 if the relay has not been  
switched on since 12:00 the previous day.  
Set parameter n.8 in the installer set -  
up mode to 1.  
While in Holiday mode the Pump Exercise feature, if  
enabled, will operate.  
Upper Temperature  
Limit  
The normal upper temperature limit of 30 oC can be  
Set parameter n.11 in the installer set  
reduced down to 21 oC to save energy. Useful for small -up mode to the desired limit.  
commercial premises.  
Lower Temperature  
Limit  
The normal lower temperature limit of 5 oC can be  
increased up to 16 oC to protect the inhabitants from  
cold. Useful if the inhabitants include the elderly,  
children or disabled.  
Set parameter n.12 in the installer set  
-up mode to the desired limit.  
Temperature Offset  
If the Chronotherm is located in a hot/cold location and Set parameter n.13 in the installer set  
cannot be moved because of wiring then the measured/ -up mode to the desired offset value.  
displayed temperature can be adjusted by +/- 3 oC.  
Useful if the homeowner wants the reading to match  
another appliance temperature display.  
Proportional Band Width Can be adjusted up to 3 oC (default is 1.5 oC) to provide Set parameter n.15 in the installer set  
better temperature control (less overshoot).  
-up mode to the desired value.  
Useful for:  
a. Well insulated homes with over-sized heating  
systems  
b. Air systems with fast response  
Optional  
Accessories  
Description  
What to do if we wish this  
feature  
Outside Temperature  
Sensor  
An Outside Temperature Sensor can be fitted to your  
CM67 to allow the homeowner to display the outside  
temperate on the Chronotherm display by using the  
INFO i button. CM67 will read the outside temperature  
every 10 minutes. Outside temperature display range is  
from -30 oC to +45 oC. The sensor can be connected up  
to 50 meters from the unit.  
1. Fit the sensor (instructions  
included in the sensor package)  
2. Set parameter n. 10 in the  
installer set-up mode to 1  
Remote Temperature  
Sensor  
A Remote Temperature Sensor can be fitted to your  
CM67 to allow the Chronotherm to control temperature  
from another room or space where it is inconvenient to  
locate the CM67 It will read the remote sensor every 1  
minute. The sensor can be connected up to 50 meters  
from the unit. Useful for commercial premises where  
the public may tamper with the product.  
1. Fit the sensor (instructions  
included in the sensor package)  
2. Set parameter n. 10 in the  
installer set-up mode to 2  
Automatic Time Setting  
(ATS) Module  
The ATS module picks up a time signal daily from a  
European transmitter, so you never need to set or  
adjust the time.  
1. Fit the ATS module  
2. Set parameter n. 4 in the installer  
set-up mode to 1  
EN0R 8498 R2 11/98  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
CM67 CHRONOTHERM  
Parameter  
Installer Set-  
Up Number /  
Abbreviation  
(Press + or -  
key to  
Factory Setting  
Optional Setting  
Installer Set-  
Up Category  
(Press keys  
PROG 1 or 2  
to select)  
1 2  
change)  
Display  
Description  
Display/Setting  
Description  
Optimisation  
1:0P  
2:0t  
0
1
Optimisation disabled  
1
Optimisation enabled  
1
1
MinimumONTime  
1minuteminimumONtime  
2to5  
2- 2minutes  
3 - 3 minutes  
4 - 4 minutes  
5 - 5 minutes  
AM-PM / 24hr Display  
Accessory Module Type  
3:Cl  
4:At  
0
0
24 hr clock display  
1
12hrAM/PMclockdisplay  
1
1
No accessory module  
plugged in  
1, 2  
1 - Auto Time Setting Module  
2 - Weatherstation Module  
RESET Time /  
Temperature Program  
5:rP  
1
Time / Temperature profile set  
to factory default  
Changes to 0 when one of the  
time/temp profiles are changed  
0
1
Time / Temperature are as  
programmed  
To restore the factory profile  
set to 1  
1
You must now press the PROG 2 key to enter the next section  
Heat / Cool Operation  
Electric Heat  
6:HC  
7:Eh  
8:PE  
9:Cr  
1
0
0
6
Heating Operation  
0
Cooling Operation  
2
2
2
2
Applications < 3A  
1
1
Applications 3 - 8A  
Pump Exercise Enabled  
Pump Exercise  
Cycle Rate  
Pump Exercise Disabled  
6 cycles per hour (cph) for gas  
boilers, zone valves and fan-  
coil  
3, 9, 12  
3 - 3 cph  
9 - 9cph  
12 - 12 cph  
Second Temperature  
Sensor  
10:SS  
0
No sensor fitted  
1, 2  
1 - Outside Temperature  
Sensor fitted  
2
2 - Remote Temp. Sensor  
fitted  
Upper Temperature Limit  
Lower Temperature Limit  
Temperature Offset  
11:UL  
12:LL  
13:tO  
14:PO  
30  
5
30°C Upper Temp. Limit  
5°C Lower Temp. Limit  
No offset  
21 to 29  
6 to 16  
21°C to 29°C adjustment in  
1°C steps  
2
2
2
2
6°C to 16°C adjustment in  
1°C steps  
0
-3 to +3  
-99 to +3  
-3°C to +3°C adjustment in  
0.1°C steps  
Pressure Offset  
(needed for  
0
No offset  
-99 mbar to +99 mbar  
adjustment in 1 mbar steps  
Weatherstation accessory  
only)  
Proportional Band Width  
15:Pb  
16:FS  
1.5  
1
1.5°C Proportional Band  
1.6 to 3.0  
1.6°C to 3.0°C adjustment in  
0.1°C steps  
2
2
Return all Set-Up  
Features to Factory  
Settings  
All settings held are the factory  
defaults. Changes to 0 when  
one of the parameter values  
are changed  
0
1
Settings are as modified  
above  
To restore the factory profile  
set to 1  
5
EN0R 8498 R2 11/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CM67 CHRONOTHERM  
DIMENSIONS  
INSTALLATION  
LOCATION  
The CM67 Chronotherm is the temperature control element  
in the heating/cooling system and MUST be located in a  
position with good air circulation at average room  
temperature on an inside wall 1.5 metres above the floor  
level. Do not position the CM67 Chronotherm near sources  
of heat (radiators, hot air vents, TV or lights), near doors or  
windows, or in direct sunlight.  
MOUNTING  
The CM67 Chronotherm can be mounted directly on the wall  
surface or on an electrical wallbox.  
WIRING  
The CM67 Chronotherm is designed for fixed wiring only and  
must be installed in accordance with latest l.E.E. regulations.  
Ensure the wiring connection to the supply is via a fuse rated  
at no more than 8 amps and a Class "A" switch (having  
contact separation of at least 3 mm in all poles).  
IMPORTANT  
1. The installer must be a trained service engineer  
2. Disconnect the power supply before beginning  
installation  
EN0R 8498 R2 11/98  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CM67 CHRONOTHERM  
WIRING  
ORDERING SPECIFICATION  
Description  
Model  
Logo  
Literature  
Spec Sheet  
NOTE: The model shown opposite  
can be ordered as samples to  
establish the exact  
7-day  
programmable  
thermostat  
T6667B1002  
Honeywell  
English  
ENOR8498  
customisation requirements  
Remote sensor T7043G1004  
Honeywell  
Multi-  
Language  
ENOR8496  
ENOR8495  
ENOR8501  
Outside temp  
sensor  
F42009537-  
001  
Multi-  
Language  
Automatic  
Time Setting  
Module Europe  
Q6667B1007  
Multi-  
Language  
Honeywell Control Systems Limited  
Newhouse Industrial Estate  
Motherwell ML1 5SB  
United Kingdom  
EN0R 8498 R2 11/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Drill G0705 User Manual
Hafler Stereo Amplifier DH 500 User Manual
Haier Flat Panel Television 15HL25S User Manual
Hamilton Beach Slow Cooker 33245 User Manual
Harbor Freight Tools Nail Gun 95718 User Manual
HP Hewlett Packard Photo Printer Pro B8850 User Manual
HP Hewlett Packard Server 648375 001 User Manual
HTC PDAs Smartphones Mogul User Manual
Huawei Network Card E1762 User Manual
Husqvarna Chainsaw 1151437 95 User Manual