GSW Water Heater FlowThru User Manual

STORAGE TANKS FOR  
INSTANTANEOUS WATER  
HEATERS  
INSTALLATION AND OPERATING INSTRUCTIONS  
®
For FlowThru Brands  
Read and understand these instructions thoroughly before starting  
TABLE OF CONTENTS  
I)  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
II) Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
III) Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
IV) Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
V) Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8  
PLEASE RETAIN THESE INSTRUCTIONS IN A  
SAFE LOCATION FOR FUTURE REFERENCE  
WARNING:  
Improper installation, adjustment, alter-  
ation, service or maintenance can cause  
injury or property damage. Refer to this  
manual. For assistance or additional infor-  
mation, consult a qualified installer, serv-  
ice agency or the electric utility.  
FOR YOUR SAFETY  
• Do not store or use gasoline or other  
flammable vapors and liquids in the  
vicinity of this or any other appliance.  
• Installation and service must be per-  
formed by a qualified installer, service  
agency or the electric utility.  
WARNING:  
If the information in these instructions is  
not followed exactly, a fire or explosion  
may result causing property damage, per-  
sonal injury or death.  
GSW Water Heating is a division of GSW Water Products Inc.  
PART NO. 71800 REV. B (06-07)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
I) INTRODUCTION  
III) INSTALLATION  
Thank you for purchasing this FlowThru® storage tank.  
Properly installed and maintained, it will provide years of  
trouble free service.  
WARNING  
Excessive Weight Hazard  
Use two or more people to move and install  
storage tank. Failure to do so can result in  
back or other injury.  
The warranty on this storage tank is in effect only when the  
tank is installed and operated in accordance with these  
instructions. The manufacturer of this tank will not be liable  
for any injury or property damage resulting from failure to  
comply with these instructions.  
Local Codes  
The installation of this storage tank must be In accordance  
with these Instructions and all applicable local codes.  
IMPORTANT: Read and understand these instructions  
before installing and operating your storage tank.  
Location  
Description  
Locate the storage tank in a clean dry area close to the  
water-heating source and preferably central to the piping  
system. Adequate clearance for accessibility to permit main-  
tenance and service must be provided. Water lines and the  
storage tank should be protected from freezing tempera-  
tures. Do not install the storage tank in outdoor unprotected  
areas. It is necessary to have a floor drain nearby to permit  
easy draining (see Figure 1).  
The FlowThru® series of storage tanks have been designed  
to supply hot water for domestic use when combined with a  
tankless coil boiler or instantaneous water heater (IWH).  
Each tank is equipped with an adjustable thermostat, pre-  
wired and ready for connection to a circulator pump (not  
supplied). These tanks are not constructed to ASME  
requirements and should not be used for such applications.  
The FlowThru® series of storage tanks has been optimized  
to maximize hot water flow rate capabilities of an instanta-  
neous water heater or tankless coil boiler. They provide a  
faster recovery than regular electric or gas-fired tank type  
water heaters of the same storage capacity. Always use a  
mixing valve on the hot water outlet (not provided).  
IMPORTANT  
This storage tank must be installed strictly in accordance  
with the instructions enclosed, and local electrical, fuel  
and building codes. It is possible that connections to the  
tank, or the tank itself, may develop leaks. IT IS THERE-  
FORE IMPERATIVE that the storage tank be installed so  
that any leakage of the tank or related water piping is  
directed to an adequate drain in such a manner that it can-  
not damage the building, furniture, floor covering, adja-  
cent areas, lower floors of the structure or other property  
subject to water damage. This is particularly important if  
the tank is installed in a multi-story building, on finished  
flooring or carpeted surfaces. GSW WILL NOT ASSUME  
ANY LIABILITY for damage caused by water leaking from  
the storage tank, pressure relief valve, or related fittings.  
Select a location as centralized within the piping system  
as possible. In any location selected, it is recommended  
that a suitable drain pan be installed under the storage  
tank. This pan must limit the water level to a MAXIMUM  
depth of 45mm (1 3/4 in.) and have a diameter that is a  
minimum of 50mm (2 in.) greater than the diameter of the  
storage tank. Suitable piping shall connect the drain pan  
to a properly operating floor drain.  
II) SAFETY  
Relief Valve Requirements  
For protection against excessive temperatures and pres-  
sure, install temperature and pressure protective equipment  
required by local codes, but no less than a combination  
Temperature and Pressure (T&P) Relief Valve certified as  
meeting the requirements for “Standard For Relief Valves  
For Hot Water Supply Systems, ANSI Z21.22/CSA 4.4”.  
The valve shall be marked with a maximum set pressure not  
to exceed the maximum working pressure of the storage  
tank. The T&P valve shall be rated for the BTU INPUT of the  
entire system. This T&P valve may be in addition to any  
T&P valve that is required on the boiler or instantaneous  
water heater system. Install the valve into the opening pro-  
vided on the storage tank, or other approved system loca-  
tion. Provide tubing so that any discharge from the valve will  
exit within 152mm (6 in.) above, or any distance below the  
structural floor and cannot contact any live electrical part.  
The end of the relief pipe opening should terminate near the  
floor drain or other suitable location. Do not place a valve(s)  
or any other blockage or restrictions between the tank and  
the T&P valve.  
Circulator Pump  
A circulator pump is not supplied. Use only a bronze body  
model rated for 110/120 volts, 60Hz. Install in accordance  
with the pump manufacturer’s instructions using standard  
plumbing practices. Size the circulator pump taking into  
account the pressure loss through the tankless coil boiler or  
instantaneous water heater as well as pressure losses  
through the connecting pipes that are part of the circulating  
loop.  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Ensure the storage tank is level before starting installa-  
tion.  
2. Install a circulation loop as shown using 19mm (3/4 in.)  
copper piping.  
Sizing The Hot Water System  
Temperature of the system is controlled by the temperature  
set point of the instantaneous water heater or boiler coil.  
Given the limited storage capacity of the storage tank and  
the maximum output of the tankless coil boiler or instanta-  
neous water heater, large hot water draws significantly  
exceeding the circulating loop flow rate may lead to a reduc-  
tion in temperature of hot water delivered.  
3. If the heating source is a tankless coil boiler go to step  
4. If a temperature controlled IWH is used as a heat  
source, install the combination inlet/drain valve in one  
“arm” of a tee connected to the lower storage tank fit-  
ting. Connect the cold water supply piping to the inlet of  
the combination inlet/drain valve. Connect the other  
“arm” of this tee to the IWH inlet line and place the cir-  
culating pump in this line. Connect the IWH outlet to the  
upper storage tank side fitting (see Figure 2). Proceed  
to step 5.  
4. For a tankless coil boiler install the combination  
inlet/drain valve in the lower storage tank fitting.  
Connect the inlet of the combination inlet/drain valve to  
the hot outlet of the tankless coil boiler. In this instance  
the “leg” of a tee should connect to the cold water sup-  
ply line, one “arm” connects to the circulator pump and  
the other “arm” to the inlet of the tankless coil boiler. The  
circulator pump connects to the upper side fitting.of  
storage tank (see Figure 3).  
Plumbing Connections  
WARNING  
The water heating source piping and components con-  
nected to the tank must be suitable for potable water use.  
TOXIC chemicals such as used for boiler treatment must  
not be introduced into the tank.  
For a temperature controlled instantaneous water heater it  
is recommended to install the plumbing as shown in Figure  
2. It is also recommended to set-up and control the IWH out-  
let temperature to be at least 11°C (20°F) above tank ther-  
mostat temperature. The recommended plumbing installa-  
tion for a tankless coil boiler is shown in Figure 3. In this  
case, because the tankless coil boiler is able to control only  
the differential between inlet and outlet temperature, the  
cold water entering the tankless coil boiler must be tem-  
pered with hot water from the storage tank. As there is a  
large variety of heat sources and control systems, please  
contact your local distributor for the plumbing system to  
identify the solution that best suits your application.  
COLD  
MIXING  
VALVE  
HOT  
TEMPERATURE  
CONTROLLED  
IWH  
STORAGE  
TANK  
T&P  
VALVE  
Important  
Do not apply heat directly to tank fittings when making  
sweat connections. They contain non-metallic material.  
T
CIRCULATOR  
PUMP  
DRAIN  
COLD  
EXPANSION TANK  
(OPTIONAL)  
CHECK  
VALVE  
HOT  
WATER  
NOTE ORIENTATION  
OF J-TUBE  
Figure 2 Single Storage Tank Plumbing for a  
Temperature Controlled IWH  
T&P VALVE  
CHECK VALVE  
EXPANSION TANK (OPTIONAL)  
PRESSURE  
REGULATOR  
(OPTIONAL)  
PIPE INSULATION  
CIRCULATOR  
PUMP  
COLD  
HOT  
FROM IWH  
MIXING  
VALVE  
COLD  
THERMOSTAT  
WITH HIGH-  
LIMIT SWITCH  
TO IWH &  
CIRCULATOR  
PUMP  
T&P VALVE  
HOT  
STORAGE  
BOOSTER  
TANK  
T
NON-TEMPERA-  
TURE CON-  
TROLLED TANK-  
LESS COIL BOILER  
DRAIN PAN  
COMBINATION  
INLET/DRAIN VALVE  
COLD IN  
DRAIN VALVE  
FLOOR DRAIN  
Figure 1 Main Parts and Features for Connection to a  
Figure 3 Single Storage Tank Plumbing for a Non-  
Temperature Controlled IWH  
Temperature Controlled Tankless Coil Boiler  
- 4 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. Pay attention to the desired flow direction when  
installing the circulator pump. If the pump does not have  
a check valve embedded install one to ensure the  
desired flow direction is maintained during system oper-  
ation.  
L
N
GROUND  
6. Install a mixing valve with the hot port going to the top  
tank fitting. Connect the domestic hot water supply line  
to the mixing port of the mixing valve. Connect the cold  
port of the mixing valve to the cold water supply line and  
place a shut-off in this line. Most mixing valves do not  
operate properly if the pressure differential between hot  
and cold port is too high. If this happens, lower mixed  
water temperature will be provided. The shut-off valve  
should be used to adjust this pressure differential. Set  
the mixing valve outlet temperature to 49°C (120°F) to  
avoid scalding.  
CIRCULATOR PUMP  
(FIELD PROVIDED)  
JUNCTION BOX  
(AT CASING TOP)  
BLACK  
1
WHITE  
3
4
2
1
2
7. A check valve may be installed in the cold water line  
before the connecting tee.  
BLACK  
NOTE: The check valve can often be noisy and cause  
reduced supply pressures. For multiple storage tank sys-  
tems, check valves must be installed to prevent the circula-  
tor pump from pumping hot water into another tank and  
overheating it.  
Figure 4 Wiring Diagram  
4. The thermostat is rated for a maximum inductive current  
of 7 FLA at 120 VAC. Do not exceed this rating for the  
circuit.  
5. Do not install or connect electrical heating elements to  
this tank.  
8. The use of a pressure regulator is optional, but recom-  
mended when the cold supply pressure is over 80 psi.  
Reducing the inlet pressure to 45-60 psi will reduce  
probability of relief valve discharge due to thermal  
expansion.  
9. The water utility supply meter may contain a check  
valve, back-flow preventer or water pressure-reducing  
valve. This will create a closed water system. During a  
heating cycle, water expands creating a pressure  
buildup in the water system. A Temperature and  
Pressure (T&P) Relief Valve must be installed (150 psi  
maximum pressure). See preceding section. If the T&P  
valve discharges periodically, it may be due to thermal  
expansion in a closed system. To prevent this condition  
and to reduce the possible buildup of lime on the T&P  
Relief Valve seat, install a thermal expansion tank in the  
circulating loop as shown in Figure 2 and 3.  
Filling  
NOTE: When filling, avoid water leakage. Do not allow the  
insulation of the tank to get wet as water can cause electri-  
cal malfunction or reduce the effectiveness of the insulation.  
1. To insure complete filling of the tank, allow air to exit by  
opening a hot water faucet that is served by the tank  
and is some distance away from the heater.  
2. Ensure the storage tank drain valve is closed.  
3. Open the cold water supply valve and fill the tank and  
piping system with water. When an uninterrupted  
stream of water, without apparent air bubbles, flows  
from the open hot water faucet, the system is full.  
4. Close the open hot water faucet. Check the system for  
leaks, repair as necessary and retest.  
10. Some jurisdictions require a Vacuum Relief Valve to be  
installed. Such a valve allows air to enter the piping sys-  
tem thus preventing vacuum conditions that could  
siphon water from the system. Check local code  
requirements.  
5. Connect a hose to the drain valve and route to a suit-  
able drain. Open the drain valve and let water run to  
flush out any foreign matter that may have entered the  
system. Once flushed, close the drain valve and dis-  
connect hose.  
Electrical Wiring  
IV) OPERATION  
1. Follow boiler or instantaneous water heater installation  
and operating instructions.  
2. Fill the tank (see “Filling” section).  
3. The boiler or instantaneous water heater should be set  
to provide at least 11°C (20°F) higher water temperature  
than the temperature setting of the storage tank.  
4. Turn power on, check for proper operation of boiler or  
instantaneous water heater and storage tank.  
Electrical wiring must be in accordance with local codes or,  
in the absence of such codes, with the “Canadian  
Electrical Code, Part I, (C22.1)” or the “National  
Electrical Code, (NFPA 70)” as applicable.  
1. Supply 110/120 volts, 60Hz power, to the junction box  
located at the top of the tank.  
2. Connect the circulator pump in series with the thermo-  
stat as shown in Figure 4.  
3. A ground wire must be supplied from the ground con-  
nection at the service panel to the ground screw at the  
junction box.  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. If at the end of the recovery cycle, the IWH is OFF but  
the circulator pump does not turn OFF automatically,  
reduce the storage tank thermostat set point until the  
pump shuts off. Check that pump is off.  
Temperature Adjustment  
DANGER  
Temperature Limit Control  
For safety, a non-adjustable high limit temperature switch  
will shut off the power when excessive water temperatures  
are reached. This switch must be re-set manually.  
V) MAINTENANCE  
Temperature and Pressure Relief Valve  
Manually operate the temperature and pressure relief valve  
at least once a year to make sure it is working properly. To  
prevent water damage, the valve must be properly connect-  
ed to a discharge line that terminates at an adequate drain.  
Water temperature over 52°C (125°F) can cause  
severe burns instantly or death from scalds.  
CAUTION  
The out-flowing water is hot. Avoid splashing the water on  
yourself or on the surroundings where it may cause dam-  
age.  
Children, disabled and elderly are at highest risk of  
being scalded.  
See instruction manual before setting temperature  
at the storage tank.  
Standing clear of the outlet (discharged water may be  
hot), slowly lift and release the lever handle on the temper-  
ature and pressure relief valve (see Figure 5) to allow the  
valve to operate freely and return to its closed position. If the  
valve fails to completely reset and continues to release  
water, immediately turn "OFF" the electrical supply to the  
tank, close the cold water supply valve and call a qualified  
service technician.  
Feel water before bathing or showering.  
Temperature limiting valves are available, see man-  
ual.  
Thermostats are factory set at 140°F (60°C). The thermo-  
stat operates automatically. It can be adjusted to provide a  
higher or lower water temperature.  
If water temperature adjustment is required:  
1. Turn the electrical supply "OFF".  
TEMPERATURE AND  
PRESSURE RELIEF VALVE  
2. Remove the access door and insulation pad.  
3. Check with a voltage tester at terminal 1 and 3 of the limit  
control that power is indeed "OFF".  
MANUAL RELIEF VALVE  
4. Adjust the thermostat to the water temperature desired.  
5. Ensure insulation pad is in the door cavity. Replace  
access door(s).  
6. Turn the electrical supply "ON".  
WARNING:  
Risk of scalding  
There is a hot water scald potential if the thermostat is set  
too high.  
DISCHARGE LINE TO DRAIN  
Figure 5 T&P Relief Valve Test  
Adjusting the thermostat past the 49°C (120°F) bar on the  
temperature dial will increase the risk of scald injury. Hot  
water can cause severe burns in:  
Draining and Flushing  
It is recommended that the storage tank be drained and  
flushed every 6 months to remove sediment that may build  
up during operation. The storage tank should also be  
drained if being shut down for extended periods of time. To  
drain the tank, perform the following steps:  
1 1/2 seconds at. . . . . . . . . . . . . . 66°C (150°F)  
3 seconds at. . . . . . . . . . . . . . . . . 60°C (140°F)  
20 seconds at. . . . . . . . . . . . . . . . 54°C (130°F)  
CAUTION  
Initial Temperature Adjustment  
1. For the temperature controlled IWH, ensure the tem-  
perature set point is 11°C (20°F) higher than the storage  
tank set point.  
The water being drained can be extremely hot! The  
drain hose should be rated for at least 93°C (200°F). If the  
drain hose does not have this rating, open the cold water  
supply valve and a nearby hot water faucet served by the  
system until the water flow is no longer hot. Close the cold  
water supply valve and resume.  
- 6 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Turn "OFF" the electrical supply to the tank.  
2. Close the cold water supply valve.  
5. Using an adjustable pipe wrench, remove the anode  
and inspect it. The surface may be rough, full of pits and  
crevices, but this is normal. If it is less than approxi-  
mately 6mm (1/4 in.) in diameter, or the inner steel core  
is exposed, the anode should be replaced.  
3. Open a nearby hot water faucet served by the system.  
4. Connect a hose to the drain valve and route it to an  
adequate drain.  
5. Open the drain valve and allow all the water to drain 6. Apply TeflonTM tape or sealing compounds approved for  
from the tank.  
use with potable water, to the threads of the anode and  
install into the tank top.  
6. Open the cold water supply valve and flush the tank as  
needed to remove sediment and any other foreign mat- 7. Open the cold water supply valve and open a nearby  
ter that may have entered the system. Close the cold  
water supply valve when clean water flows.  
hot water faucet to purge air from the tank as directed  
in the “Filling” section.  
7. Perform any other servicing as required.  
8. Check for leaks, repair as required, and re-test.  
8. Close the drain valve, disconnect hose and refill the 9. Turn "ON" the electrical supply to the tank.  
tank (see “Filling” section). If the water heater is going  
to be shut down for an extended period, the drain valve  
should be left open.  
9. Turn "ON" the electrical supply to the tank.  
Water Odor/Sacrificial Anode  
Your storage tank has been equipped with one magnesium  
anode that will slowly deplete while protecting the glass-  
lined tank thus prolonging its life. Certain water conditions  
may cause a reaction between the anode and the water.  
The most common complaint associated with the anode is  
a “rotten egg smell” produced by the presence of sulfur. Do  
not remove this anode permanently as it will void any  
warranties, stated or implied. An aluminum anode may  
reduce if not eliminate water odor problems. The water sup-  
ply system may require special filtration equipment from a  
water conditioning company to successfully eliminate all  
water odor problems. Artificially softened water is exceed-  
ingly corrosive because the process substitutes sodium ions  
for magnesium and calcium ions. The use of a water sof-  
tener may decrease the life of the water heater tank. The  
anode should be inspected periodically. If the anode is more  
than 50% depleted, the anode should be replaced.  
Anode Maintenance  
1. Turn "OFF" the electrical supply to the tank.  
2. Close the cold water supply valve.  
3. Open a nearby hot water faucet served by the system  
to depressurize the system.  
4. Connect a hose to the drain valve and drain 22 litres (6  
gal.) as directed in the “Draining and Flushing” section.  
CAUTION  
Hydrogen gas can be produced in a hot water system  
served by this storage tank that has not been used for a  
long period of time (generally two (2) weeks or more).  
Hydrogen gas is extremely flammable and can ignite  
when exposed to a spark or flame. To reduce the risk of  
injury under these conditions, it is recommended that the  
hot water faucet be opened for several minutes at the  
kitchen sink before using any electrical appliance con-  
nected to the hot water system. Use caution in opening  
faucets. If hydrogen is present, there will probably be an  
unusual sound such as air escaping through the pipe as  
the water begins to flow. There should be no smoking or  
open flame near the faucet at the time it is open.  
- 7 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
~ Certificate of Warranty ~  
See Rating Label Serial Number prefix for  
Warranty Code: P R S T U V W  
Y
Warranty Code. Reduced warranty period  
applies to Newfoundland.  
Standard Warranty Years: 3 5 6 7 8 9 10 12  
Reduced Warranty Years: 2 3 3 5 5 5  
5
7
For its GSW and John Wood water heaters and storage boosters ("Unit"), GSW Water Heating ("GSW") warrants that, upon  
receipt of a properly verified Warranty claim within the Warranty Period, it will, at its election, repair or replace: units which leak or parts which are defective  
in material or workmanship, subject to the terms and conditions set forth in this certificate. GSW will not assume any expense or liability for unauthorized  
returns, nor repairs made by a person who has not been authorized by GSW or one of its authorized dealers. GSW Units/parts must be replaced with GSW or  
John Wood products to be eligible for Warranty. This Warranty is available to the original owner of a Unit installed within the boundaries of continental United  
States, of Canada, or their territories. Consumers must retain point-of-sale proof of purchase to validate warranty entitlement. This Warranty does not  
cover components not manufactured by GSW, such as oil burners, which carry the warranty given by the manufacturer thereof, copy of which warranty GSW  
will make available, to the extent supplied by the manufacturer, without recourse to GSW.  
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THIS EXPRESS  
WARRANTY IS, WHERE PERMITTED BY LAW, IN LIEU OF AND EXCLUDES AND REPLACES ALL OTHER CONDITIONS,  
WARRANTIES, GUARANTEES, REPRESENTATIONS, OBLIGATIONS OR LIABILITIES OF GSW OF ANY NATURE OR KIND,  
EXPRESS OR IMPLIED, HOWEVER ARISING (WHETHER BY CONTRACT, CONDUCT, STATEMENT, STATUTE, NEGLI-  
GENCE, PRINCIPLES OF MANUFACTURER'S LIABILITY, OPERATION OF LAW OR OTHERWISE) WITH RESPECT TO THE  
UNIT OR ITS FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, INSTALLATION, OPERATION, REPAIR OR  
REPLACEMENT. GSW EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES. IN NO EVENT WILL GSW'S LIA-  
BILITIES EXCEED THE COST OF THE DEFECTIVE PART(S) OR UNIT. GSW WILL NOT PAY FOR ANY TRANSPORTATION,  
LABOUR, INSTALLATION, OR OTHER INCIDENTAL COSTS ASSOCIATED WITH THE REPAIR OR REPLACEMENT OF A  
DEFECTIVE PART OR UNIT.  
This warranty and GSW's obligations shall be construed and determined in accordance with the laws of both the Province of Ontario, and of Canada in force  
therein. This Warranty does not affect specific legal rights of a consumer under applicable law, except to the extent that such rights may be waived or replaced,  
and the provisions hereof are deemed to be amended to the extent necessary. The unenforceability of any provision, in whole or in part, of this Certificate shall  
not affect the remaining provisions. Any and all repair and/or replacement of part(s) or Unit are the sole and exclusive remedy available against GSW.  
LIABILITY OF GSW COVERED BY THIS WARRANTY IS CONDITIONAL UPON THE FOLLOWING:  
1. The Unit shall be installed in accordance with all manufacturers' instruc- 7. A properly documented claim shall be received by GSW or one of its  
tions, all applicable equipment and building codes, ordinances and regu-  
lations (hereinafter referred to as the "standards").  
authorized dealers, or point of purchase, within the following Warranty  
Period, except as provided otherwise below*:  
2. The Unit must not be installed where water damage can result from a  
leak, while provision(s) shall be made for directing any water escaping  
from the Unit, to a properly operating drainpipe. As all units of this type  
may eventually leak, you must protect against any potential water dam-  
age. GSW accepts no responsibility for such damage, nor any incidental  
or consequential loss, nor damage(s) related thereto, suffered by the  
owner of the Unit nor by any third party.  
3. The Unit shall not be installed where it will be exposed to adverse or  
unusual environmental or corrosive conditions. No warranty extends, for  
example, and without limitation of the foregoing, to Units exposed to:  
salts; chemicals; exhausts; pollutants or contaminants. Further, no war-  
ranty extends to Units affected by fire, freezing or flood, "Acts of God",  
or any other contingency beyond the control of GSW.  
a) for any defective part, within one (1) year; or  
b) for any Unit that develops leaks in the inner tank due to rust, corrosion  
or other chemical reactions caused by the potable domestic water sup-  
plied to your home, within the period of time shown in table at the top of  
this page.  
* Residential units installed and used in a commercial application carry a  
warranty period of one (1) year from date of installation; and,  
Any repair or replacement of any part, tank, or Unit under this Warranty  
will not extend the Warranty Period beyond that calculated from the date  
of first installation of the original Unit. The date of first installation will  
be deemed to be the later of the date indicated by the Unit's serial num-  
ber, or if supplied with the Warranty claim, the sales receipt, or installer's  
receipt.  
4. The Unit shall be equipped with a properly operating temperature and 8. A claim under this Warranty must include the model and serial number of  
pressure relief valve as specified by GSW and applicable standards. The  
Unit shall be operated at temperatures not exceeding the maximum set-  
ting of the thermostat and/or high limit control provided by GSW, and at  
water pressures not exceeding the pressure reading stated on the Unit.  
5. The Unit must be carefully inspected, maintained, and operated in accor-  
dance with the manufacturer's instructions. No warranty extends, for  
example, and without limitation of the foregoing, to any Unit operated:  
without the tank being completely filled with water; without an operating  
anode; with levels of sediment or lime precipitate which cause failure; in  
connection to any attachment(s), energy saving device(s), or other means  
the Unit, proof of date on which the Unit was first installed, and the iden-  
tity of the defective part(s) for which a claim is being made and be sub-  
mitted within 15 days following discovery of the defect(s), by personal  
delivery to a GSW authorized dealer, point of purchase, or GSW itself at:  
GSW Water Heating  
GSW Water Heating is a division of GSW Water Products Inc.  
599 Hill Street West  
Fergus, ON Canada N1M 2X1  
Should you have questions, please call our Technical Support Line at 1-  
888-479-8324.  
of heating, except as approved by GSW for the Unit; other than with 9. If requested by GSW, information relating to the purchase, transportation,  
potable water without any additives such as salts, chlorine or chemicals,  
except those added for the sole purpose of rendering the water fit for  
domestic use.  
operation and installation of the Unit must be supplied. The defective  
part(s) or Unit, with all components properly and securely packed, shall  
be returned transportation pre-paid, to the address designated by GSW in  
the written request. All claims are subject to validation by GSW.  
6. All repairs must be made by a competent and qualified person who is cer-  
tified, by GSW or one of its authorized dealers, to work on the Unit, using  
factory approved replacement parts, and the Unit shall not be otherwise  
modified, altered or improperly repaired.  
Download from Www.Somanuals.c-om8. -All Manuals Search And Download.  

Graco High Chair 1762138 User Manual
Grizzly Grinder H0588 User Manual
Haier Flat Panel Television 32T51 User Manual
Harman Kardon Stereo Receiver AVR 660 User Manual
Havis Shields Automobile Accessories C 3610 CV User Manual
Heat Glo LifeStyle Indoor Fireplace 7000XLT User Manual
Honeywell Photo Scanner 1902 User Manual
Hotpoint Clothes Dryer CTD80 User Manual
Hotpoint Refrigerator FF200TP User Manual
HP Hewlett Packard Network Hardware 2nd edition User Manual