ST-630E Stand-Alone Access Control
Operation Manual
Ⅰ Features
z
z
z
z
z
Master Card and Codes
Auto Reset Function
Security System Setting/ Release
Synchronize with Security System
Entering/Exiting Programming Mode: Only Proximity
Codes + Proximity, Codes or Proximity
Door Status Monitor Function
z
z
z
Anti Pass Back Function
Emergent Access Alarm, Time Delay Alarm and Forced
Door Alarm output
z
z
z
Dual relays programmable On/Off or pulsed or latched mode
LED Indicator to distinguish the status
Use for all kinds of the electric lock.
Ⅱ. The Specifications:
Part No.
ST-630E
Connection
/Users
Connection/ Stand-alone
1000
/Record Volumes
Reader Application
Keys
1000
WG26,WG34
12 Keys (0-9,*,#)
Interface
RS485
Proximity Distance
Proximity
About 125 and 15 cm/13.56 for around 7 cm
125Khz (EM)
Frequency
Indicators
3 LEDs
Dimension (mm)
114(L) x 69.5(W) x 10(D)mm
12 VDC
-5 C-60 C
Operating Voltage:
Temperature
5%-95%(Non-condensing)
Humidity
Copyright All Rights Reserved.
Page 1 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Download from Www.Somanuals.com. All Manuals Search And Download.
Ⅳ Operation Instruction:
Enter Program Mode,Enter 6-digital Codes,(Default 123456)
*xxxxxx#
*
#
Exit Program Mode
01*xxxxxx xxxxxx #
02*xxxx #
Change Default Password, Press twice new 6-digital Codes
Controller Station Setting[001-254]
Access only with the password, 0000-Unavaliable (Default, 0000)
05*xxx#
10*xxxx*XXXXXXXXXX # Adding or Revised the Cards No.
Slot Position =00001~01000 and enter the 10 digital Cards No.
12*XXXX*XXXXX#
Adding the batch series Cards No.. XXXX=the beginning position
*XXXXX=the quantities of the batch series card No.
(The access mode is for Card Only)
Modify the cards access parameter
xxxxx= The beginning slot position
XXXXX= the ending slot position
(ps. x≦01000)
13*xxxxx*XXXXX*N #
From=00001~01000
N is 0= Access not allow,1=Card only, 2=Cards or Code,
3=Card & Code, 4= Clear card information
(When modify the Mode to “Card or Code” or “ Card & Code”,the
default Code is 0000.
Set the position of the Code; xxxxx=slot position XXXX=4-digital
Code (Position =00001~01000)
14*xxxxx*XXXX#
15*99#
Clear all Cards (Not including Master Cards)
When forget the Cards slot position,can clear the cards information
by enter Cards No..
17*xxxxxxxxxx#
21*xxx#
22*xxx#
Alarm Time Delay Setting xxx=000~255 Seconds
Dual relays programmable time delay xxx=000~250 Seconds
(External Relay for Security System)
(000 Latched Operation) (Default is 15 Seconds)
Master Cards Setting x=(1 or 2). 2 Master Card available
In the normal status, proximity the Master cards to Program Mode.
Security Cards arrange Setting XXXXX=00001~01000 .The arrange
of the No. should be continuing which can’t skip the No.
x=0 General Setting Mode (Default x=0)
25*X#
26*xxxxx*XXXXX#
30*x#
x=1 Card Only. Access the door by reading cards that no matter the
cards are set into the system or not.
Anti Pass Back Function
32*x#
x=0/ OFF
X=1/ ON
33*x#
Two Doors Synchronize x=0 OFF X=1 ON,Access
Copyright All Rights Reserved.
Page 3 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Download from Www.Somanuals.com. All Manuals Search And Download.
Controller and Reader can open different doors.
34*99#
Reset the function of Anti Pass Back.
x=1= access record to duty
35*x# (for connecting
controller)
x=0= access record Not to Duty
(x= default is 0)
38*x#
x=0 Green LED is controlled by Controller x=1 Green LED is
controlled by external system
(The second Relay contact to the Door Status and negatron (-) ,
Green LED flash can synchronize with Security System.
Reset to Default, and clean the controller memory to the factory
default
51*99#
55*99#
Add New Cards,read card once and 1 Beep heard for adding the
new card. Read card twice and 2 Beep heard to delete the cards.
(After add Cards,the default access mode is “Card Only”)
70*X# [For LCD series]X=0 Screen Backlight ON ,x=1 Screen Backlight Off automatically
Emergent Code Setting,Enter twice 6-Digital Code。
Enter the Code can link to the other relay to activate the external
system. 22*xxx # for setting the active time. (second)
xxx=000~255 Seconds
71*XXXXXX XXXXXX #
72*xxx#
73*x #
Door Left Open Alarm Time Delay - The door does not close after the
limited time, and the controller will output the alarm.
x=1 Enter the emergent code or press 99* with Security Cards, the
relay of the controller/ ON; X=0 OFF
74*x#
76*x#
99*
X=1 Door Left Open Alarm and Force Open Mode are ON; X=0 OFF
X=1 Emergent Alarm /ON,x=0 OFF
When setting or Release the External Relay, Please enter the
codes99*and then read the security card.
(Operating in the Normal Mode.)
Ⅴ、 Wiring diagram:
Copyright All Rights Reserved.
Page 4 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Download from Www.Somanuals.com. All Manuals Search And Download.
Copyright All Rights Reserved.
Page 5 of 5
P-MU-ST-630 Ver. A Publish: 2009.01.08
Download from Www.Somanuals.com. All Manuals Search And Download.
|