FCC Class B Notice
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance with FCC emissions limits.
N
For complete safety information about these products please read the Safety Compliances sheet, which is available online at www.extron.com
N
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
1)
2)
3)
4)
5)
6)
7)
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8)
9)
Do not install near any heat sources such as radiators, heat registers, stoves, or
other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug does not fit into
your outlet, consult an electrician for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
11) Only use attachments/accessories specified by the manufacturer.
12)
Use only with the cart, stand, tripod, bracket, or table specified by
the manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
13) Unplug this apparatus during lightning storms or when unused for long
periods of time.
14) Refer all servicing to qualified service personnel. Servicing is required when
the apparatus has been damaged in any way, such as power-supply cord
or plug is damaged, liquid has been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Chapter One • Introduction........................................................................................................1-1
About this Manual......................................................................................................................1-2
MPA 401-70V Description.......................................................................................................1-2
MPA 401-70V Features..............................................................................................................1-3
Chapter Two • Cabling....................................................................................................................2-1
Rear Panel Cabling.....................................................................................................................2-2
Chapter Three • Setup and Operation................................................................................3-1
Front Panel Features.................................................................................................................3-2
Setting Input Level.....................................................................................................................3-2
Setting Bass and Treble...........................................................................................................3-2
Remote Control Options.........................................................................................................3-3
Appendix A • Specifications, Part Numbers, Accessories................................. A-1
Specifications............................................................................................................................... A-2
Part Numbers and Accessories........................................................................................... A-4
Included.parts............................................................................................................................ A-4
Optional.parts........................................................................................................................... A-4
Appendix B • Mounting.................................................................................................................B-1
Plenum Placement......................................................................................................................B-2
Tabletop Placement...................................................................................................................B-2
Rack Mounting..............................................................................................................................B-2
UL.guidelines.for.rack.mounting.............................................................................................B-2
Rack.mounting.procedure........................................................................................................B-3
Under-desk Mounting...............................................................................................................B-3
Through-desk Mounting.........................................................................................................B-3
Pole Mounting..............................................................................................................................B-3
All trademarks mentioned in this manual are the properties of their respective owners.
68-1436-01
Rev. A
01.10
MPA 401-70V • Table of Contents
Download from Www.Somanuals.com. All Manuals Search And Download.
i
Table of Contents, cont’d
MPA 401-70V • Table of Contents
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V
Chapter One
1
Introduction
About.This.Manual
MPA.401-70V.Description
MPA.401-70V.Features
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
About this Manual
This manual contains information about the Extron MPA 401-70V mini power
amplifier with instructions for experienced installers on how to install, configure,
and operate the equipment. Unless otherwise specified, references in this manual
to the “amplifier” or “MPA” relate to the features or operation of the MPA 401-70V.
The following symbols are used throughout the manual and carry the following
meanings:
A Note icon draws attention to important information.
N
A Tip provides a suggestion to make setting up or working with the device easier.
T
A Caution icon warns of things that might damage the equipment.
C
W
A Warning icon warns of things that might cause injury, death, or other
severe consequences.
MPA 401-70V Description
The Extron MPA 401-70V integrated Mini Power Amplifier provides mono
amplification for speaker systems that require compact and economical audio
solutions. The MPA 401 accepts balanced or unbalanced, stereo or mono inputs
and provides a summed mono output. It delivers up to 40 watts (rms) for a high-
impedance, 70 V distributed sound system.
Front panel controls allow easy adjustment of bass and treble volume and input
level. Volume and muting can be controlled remotely by the Extron VCM 100,
VC 50, or MLA VC 10.
It features high efficiency, advanced Class D amplifier design with advanced
CDRS™ (Class D Ripple Suppression) technology that eliminates EMI emissions and
interference with sensitive A/V equipment. The design allows the amplifier to be
fanless and operate in environments with little or no ventilation. The MPA 401-70V
meets UL 2043 for smoke and fire code for above--the-ceiling installations.
Extron
SI 3CT LP
Extron
Full-Range
MPA 401
Mini Power
Ampliꢀer
Ceiling Speakers
Extron VC 50
Volume Controller
VOLUME
0
5
VC
n
o
r
t
x
E
Extron
MLC 104 IP Plus
Controller
Y
A
DISPL
A
401-70V
F
OF
MP
N
O
T
CLASS
2
WIRING
E
M
U
OL
OUTPUT
DO NOT GROUND
OR SHOR
V
S
A
U
m
IG
F
0
5
N
O
®
SPEAKER OUTPUTS!
10
C
D
E
V
T
IS
L
T
I
O
T
E
VOL/MUTE
7
D
1
/V
S
U
IO
T
V
D
A
0
U
R
A
A
7
P
P
A
MLC 104 IP
INPUTS
(MONO)
REMOTE
R
L
)
(MONO
L
POWER
R
X
12V
1.5A MA
RS-232
N
A
O
O
L
B
/B
-Y
U
U
T
T
T
E
S
E
R
G
/Y
P
K
LI
U
T
T
C
A
R
/R
T
-Y
ID
/V
C
/Y
-Y
,B
,Y
-
Y
/R
B
G
R
Y
C
/
H
R-
/
Y
/V
4
ID
VI
SDI
YC
I
3
N
U
P
T
T
U
P
T
R
U
O
L
UDIO
A
R
4
L
R
3
L
INPUTS
R
2
A
.3
L
V
R
0
4
-2
1
0
0
1
L
Extron
H
/60
DVS 304 DVI AD
Digital Video
Scaler
Flat Panel
Display
(DVI)
Audio
w/ Audio
R
E
IV
CE
E
R
DBS
Laptop
(RGB)
VCR
(Video)
DVD
DSS Receiver
(Component) (S-video)
MPA 401-70V • Introduction
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V Features
Patented CDRS™ (Class D Ripple Suppression) — CDRS is an Extron patented
technology that eliminates high frequency switching ripple and EMI
emissions found in all Class D amplifiers. CDRS dramatically improves
audio performance over conventional Class D amplifier designs and enables
Extron power amplifiers to be situated near wireless A/V devices without RF
interference.
UL 2043 plenum rated — The MPA 401-70V meets UL 2043 for smoke and heat
release for installation within a plenum airspace above a drop ceiling. Above-
the-ceiling placement conceals the amplifier to prevent theft and is convenient
for installing equipment when space inside the room is limited.
Although the amplifier is plenum rated, the power supply provided with it
is not. The power supply must not be placed in the plenum space. If the
amplifier is placed in a plenum space, all cables to and from it must also be
plenum rated.
C
Balanced and unbalanced buffered audio inputs — The MPA 401-70V amplifier
accepts balanced or unbalanced, stereo or mono audio input signals on a
captive screw connector, and unbalanced audio on both RCA connectors and a
3.5 mm stereo mini jack.
The MPA 401-70V amplifier mixes all right channel inputs to a single signal and
all left channel inputs to a second signal. The right signal and left signal are then
summed to produce a mono signal.
N
The three stereo inputs are individually buffered and can be connected to three
separate sources at the same time without altering performance.
Quick-plug speaker outputs — Speaker output is on a 5 mm screw lock captive
screw connector for quick installation.
ENERGY STAR® Qualified Amplifier — The MPA 401-70V amplifier is an
ENERGY STAR qualified amplifier and energy efficient product that conserves
energy and reduces costs.
Auto-standby with fast power up — automatically places the amplifier into
standby after 25 minutes of inactivity. It quickly returns to full power status
in less than one second upon signal detection. The amplifier consumes just 6
watts when idle and less than 1 watt in standby mode.
Front panel bass, treble, and input level controls — Bass, treble, and input level
are easily adjusted from the front panel.
Fanless design — The MPA 401 does not require fans or vents for cooling, ensuring
quiet, reliable operation.
Automatic clip limiter — Detects actual onset of clipping by comparing input
and output waveforms. Gain is automatically reduced with a slow attack and
fast release to eliminate clipping. This advanced limiter design protects the
speakers from clipping distortion and offers superior sonic characteristics
compared to limiters that use signal compression.
Remote volume and mute control port — A rear panel, three-pin captive screw
remote input connector allows remote adjustment of volume and muting. In
basic installations without third-party control systems, this port allows the
MPA 401 to be remotely controlled using the optional Extron VCM 100 analog
volume and mute controller or VC 50 analog volume controller.
Compact size — The 1U, quarter rack width, 6" deep metal enclosure, offers
flexible mounting options.
External universal power supply included (part # 70-725-01) — provides
worldwide power compatibility.
MPA 401-70V • Introduction
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
MPA 401-70V • Introduction
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V
Chapter Two
2
Cabling
Rear.Panel.Cabling
Download from Www.Somanuals.com. All Manuals Search And Download.
Cabling
Rear Panel Cabling
The illustration below shows the rear panel of the MPA 401-70V:
CLASS 2 WIRING
MPA 401-70V
INPUTS
(MONO)
®
US
DO NOT GROUND
OR SHORT
LISTED
AUDIO/VIDEO
APPARATUS
17TT
SPEAKER OUTPUTS!
L
10V
50mA
OUTPUT
POWER
VOL/MUTE
R
12V
1.5 A MAX
REMOTE
R
L (MONO)
70V
3
4
6
1
2
5
MPA 401-70V Rear Panel Features
Power connector — Connect the two pole, 3.5 mm captive screw connector from the
12 VDC, 1 A external power supply (provided) to this socket on the rear panel. Ensure
the connections have the correct polarity as shown below:
a
POWER
Power Receptacle
Smooth
Ridges
12V
1.5 A MAX
A
A
SECTION A–A
3/16”
(5 mm) Max.
Power Supply
Output Cord
DC Power Cord
Captive Screw Connector
Ground
+12 VDC
External
Power Supply
(12 VDC, 5 A )
AC Power Cord
The length of the exposed wires in the stripping process is critical. The ideal
length is 3/16 inches (5 mm). Any longer and the exposed wires may touch,
causing a short circuit between them. Any shorter and the wires can be easily
pulled out even if tightly fastened by the captive screws.
N
N
Do not tin the wires. Tinned wire does not hold its shape and can become loose
over time.
RCA input connectors — These connectors accept
unbalanced, line level audio signals. The input can be
stereo (using two RCA jacks) or mono (using a single
RCA jack plugged into the left/mono socket).
INPUTS
(MONO)
b
c
L
If unused, the connectors automatically terminate to
lower the noise floor.
R
3.5 mm stereo input — This input also accepts
unbalanced, line level audio signals through a 3.5 mm
tip ring sleeve (TRS) stereo jack. If unused, the connector automatically terminates to
lower the noise floor.
R
L (MONO)
MPA 401-70V • Cabling
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Balanced or unbalanced audio input connector — This 5-pole 3.5 mm captive
screw connector accepts line level, balanced or unbalanced, mono or stereo audio
d
e
Connect the input wires to the correct terminal. Connecting the ground
wire ( ) to a negative (-) terminal will damage the audio output circuits.
C
10V
50mA
Remote input connector — This 3-pole captive screw connector allows
the option of using a wall-mounted audio controller or MediaLink product to
control volume and mute levels remotely.
VOL/MUTE
Options for remote control include the Extron VC 50, VCM 100 AAP,
VCM 100 MAAP, or MLA VC10. Third party 10k potentiometer volume
REMOTE
Wire the remote control connector to the VCM 100 MAAP as shown in the figure
and instructions below:
10 V
•
•
Pin 1 is 10 VDC reference voltage.
Pin 2 (VOL/MUTE) has two functions:
2K
Volume Pot
Vol/Mute
GND
o
It can be used as a variable voltage input. 10K Ohms
Mute
Switch
The volume control DC voltage range is
0 to 10 V, with 0 V giving full attenuation
and 10 V giving maximum volume.
o
It can be used for remote control muting. Sound is muted while the mute
pin is shorted to ground.
•
Pin 3 is ground.
All nominal levels are at 10%
N
More information about remote control of the MPA 401-70V can be found on page 3-3.
Speaker connection — Connect the speakers to this socket using the 2-pole, 5 mm
f
screw-lock captive screw connector.
OUTPUT
The three left channel inputs (RCA, TRS and captive screw) are
summed to form Left Sum, with weightings proportional to
their respective sensitivities. Similarly the three right channel
inputs are summed to form a Right Sum. Left Sum and Right
Sum are mixed and amplified to provide one high voltage,
70V
mono output, which provides up to 40 W for a 70 V line distributed sound system.
Do not short the + and - outputs to each other or to the ground ( ) as this
will damage the amplifier.
C
MPA 401-70V • Cabling
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Cabling, cont’d
MPA 401-70V • Cabling
2-4
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V
Chapter Three
3
Setup and Operation
Front.Panel.Features
Setting.Input.Level
Setting.Bass.and.Treble
Remote.Control.Options
Download from Www.Somanuals.com. All Manuals Search And Download.
Setup and Operation
Front Panel Features
The illustration below shows the front panel of the MPA 401-70V.
2
LEVEL
BASS
TREBLE
1
MPA 401
MINI POWER AMPLIFIER
Power LED — The green LED is on when the MPA 401 unit is receiving power.
a
b
Potentiometers — These three front panel potentiometers are used to optimize
level, bass, and treble settings. For further details, see below.
Setting Input Level
LEVEL
BASS
TREBLE
Adjust the MPA 401-70V input level as follows:
1. If necessary, unplug the remote plug from the
unit.
MPA 401
MINI POWER AMPLIFIER
2. If connecting the amplifier to a system
with adjustable volume, set the volume
to its lowest point. Then adjust the MPA 401-70V level potentiometer fully
counterclockwise to its minimum setting.
3. Set the system volume to its maximum level. No sound should come out.
4. Slowly increase the MPA 401-70V level until sound distortion starts to occur.
Lower the level slightly until the distortion disappears. This setting ensures
that, whatever the system volume setting may be, no clipping occurs.
Setting Bass and Treble
Adjust the MPA 401-70V bass and treble as follows:
1. Use the bass potentiometer to increase or decrease the bass shelving 10 dB at
100 Hz and below.
2. Use the treble potentiometer to increase or decrease the treble shelving 10 dB
at 10 kHz and above.
Turning the bass or treble potentiometers counter clockwise will decrease the
output at the specified frequencies. Turning the potentiometers clockwise will
increase the output. When the potentiometer is at the center detent, flat response
is achieved.
N
MPA 401-70V • Setup and Operation
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Control Options
Extron
SI 3CT LP
Extron
Full-Range
MPA 401
Mini Power
Ampliꢀer
Ceiling Speakers
VOLUME
0
5
C
V
n
o
r
t
x
E
1
Extron VC 50
Volume Controller
Y
A
DISPL
A
401-70V
F
OF
MP
ON
T
CLASS
2
WIRING
OUTPUT
70V
DO NOT GROUND
OLUME
OR SHOR
2
Extron
V
S
U
50mA
®
SPEAKER OUTPUTS!
CONFIG
D
E
V
T
IS
10
L
T
I
O
T
E
VOL/MUTE
7
D
1
/V
S
U
IO
T
D
P
A
R
U
A
A
P
A
MLC 104 IP Plus
MLC 104 IP
INPUTS
(MONO)
REMOTE
Controller
R
L
(MONO)
L
POWER
R
X
12V
1.5A MA
RS-232
N
O
LA
B
B
-Y
U
U
T
G
RESET
P
/Y
LN
U
CT
A
R
/R
T
-Y
ID
/V
C
/Y
-Y
,B
,Y
-
Y
/R
B
G
R
/
R-Y
/
C
Y
/VID
SDI
YC
I
3
N
P
U
P
T
1
T
U
P
T
R
U
O
L
UDIO
A
R
4
L
R
3
L
INPUTS
R
2
A
.3
L
V
R
0
4
-2
1
0
0
1
L
Extron
H
0
/
DVS 304 DVI AD
Digital Video
Scaler
Flat Panel
Display
(DVI)
Audio
w/ Audio
R
E
IV
E
C
E
R
S
B
D
Laptop
(RGB)
VCR
(Video)
DVD
DSS Receiver
(S-video)
(Component)
10 V
Extron VCM 50 volume and mute control —
For a system designed to control the
MPA 401-70V volume directly, use a 10 k Ohm
potentiometer to control volume via the remote
port on the amplifier. Follow the instructions
in the product manual.
a
b
2K
Volume Pot
10K Ohms
Vol/Mute
Mute
Switch
GND
Using a MediaLink™ Controller — For a system with variable audio output,
connect the audio output to the amplifier’s audio input. In the above example, a
MediaLink controller adjusts the audio volume via a network connection. Follow
the instructions in the product manual.
MPA 401-70V • Setup and Operation
Download from Www.Somanuals.com. All Manuals Search And Download.
3-3
Setup and Operation, cont’d
MPA 401-70V • Setup and Operation
3-4
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V
Appendix A
A
Specifications, Part Numbers,
Accessories
Specifications
Part.Numbers.and.Accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications, Part Numbers, Accessories
Specifications
Audio
Voltage gain
RCA and TRS inputs......... 222x (47 dB)
Captive screw input.......... 57x (35 dB)
CMRR.............................................. 75 dB (typical) @ 1 kHz
Bass adjustment............................. 10 dB @ 100 Hz
Treble adjustment.......................... 10 dB @ 10 kHz
Audio input
Number/signal type..................... 1 stereo/mono, balanced/unbalanced input
2 stereo/mono, unbalanced inputs
(The three inputs are individually buffered and mixed together. Stereo
signals are actively summed into a mono signal.)
Connectors ..................................... (1) 3.5 mm captive screw connector, 5 pole (main input)
(1) 3.5 mm mini audio jack (tip, ring, sleeve [TRS])
1 pair RCA
Impedance...................................... >10k ohms balanced/unbalanced, DC coupled
Maximum level.............................. +20 dBu (balanced, captive screw) or +4 dBV (unbalanced, RCA/TRS) at
1% THD+N
Input sensitivity
RCA and TRS inputs......... -10 dBV (One input driven), -16dBV (Both inputs are summed)
Captive screw input.......... +4 dBu if driven by one input
-2 dBu if both inputs are summed
0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu
N
Audio output
Number/signal type..................... 1 single channel (mono) 70 V
Connectors ..................................... (1) 5 mm screw lock connector, 2 pole
Load impedance............................ 125 ohms minimum
Frequency response ...................... 80 Hz to 20 kHz, 3 dB, 1 watt
THD + Noise.................................. <0.2% @ 1 kHz at 3 dB below clipping
S/N.................................................. >75 dB @ 20 Hz to 20 kHz
Damping factor.............................. >100
High pass filter .............................. 80 Hz, 12 dB/octave roll off
Amplifier type ............................... Class D
Output power................................ 40 watts (rms), 70 V, 1 kHz, 1% THD
Control/remote — amplifier
Control port.................................... (1) 3.5 mm captive screw connector, 3 pole
Pin configuration........................... Pin 1 = +10 VDC (50 mA max.), pin 2 = volume/mute control (variable
voltage), pin 3 = GND
Volume control voltage range ..... 0 V (mute) to 10 V (maximum volume)
MPA 401-70V • Specifications, Part Numbers, Accessories
A-2
Download from Www.Somanuals.com. All Manuals Search And Download.
General
External power supply................. 100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 5 A (max.), regulated
Power input requirements........... 12 VDC, up to 5 A
Power draw requirements ........... For amplifier and external power suppply
Typical................................. 13 W (1/8 power [pink noise] at 125 ohms)
Quiescent............................ 8 watts
Standby............................... <1 watt (triggered by contact closure or after 25 minutes [ 5 minutes] with
no signal)
Temperature/humidity................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling ........................................... Convection, no vents
Thermal dissipation
Standby............................... <1 watt (3 BTU/hr)
Idle....................................... 6 watts (21 BTU/hr)
1/8 power (pink noise)..... 8 watts (28 BTU/hr)
Mounting
Rack mount........................ Yes, with optional 1U rack shelf or back of rack mounting kit
Furniture mount................ Yes, with optional under-desk mounting kit
Pole mount......................... Yes, with optional pole mounting kit
Enclosure type ............................... Metal
Enclosure dimensions................... 1.7" H x 4.3" W x 6.0" D (1U high, quarter rack wide)
(4.3 cm H x 10.9 cm W x 15.2 cm D)
(Depth excludes connectors.)
Product weight .............................. 0.6 lbs (0.3 kg)
Shipping weight ............................ 3 lbs (2 kg)
Vibration......................................... ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
Safety................................... CE, c-UL, UL
UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke
release, excluding the power supply; meets UL 60065 and IEC 60065 for A/V
equipment safety.
EMI/EMC .......................... CE, C-tick, FCC Class B, ICES Class B, VCCI
Environmental................... Complies with the appropriate requirements of CEC, ENERGY STAR®
(ENERGY STAR® qualified amplifier), EU code of conduct, RoHS, WEEE
MTBF............................................... 30,000 hours
Warranty......................................... 3 years parts and labor
All nominal levels are at 10%
N
N
Specifications are subject to change without notice.
MPA 401-70V • Specifications, Part Numbers, Accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
A-3
Specifications, Part Numbers, Accessories, cont’d
Part Numbers and Accessories
Included parts
Description
Part number
MPA 401-70V
60-845-01
External 12 VDC, 5 A power supply
IEC power cord
(1) 2-pole 5 mm terminal block plug
(1) 5-pin 3.5 mm captive screw plug
(1) 3-pin 3.5 mm captive screw plug
(1) 2-pin 3.5 mm power captive screw plug
(2) Velcro tape roll
Tweeker (small screwdriver)
MPA 401-70V Setup Guide
Optional parts
Description
Part number
RSU 126 1U, 6" deep, universal rack kit
RSB 126 1U, 6" deep basic rack shelf
RSU 129 1U, 9.5" deep, universal rack kit
RSB 129 1U, 9.5" deep basic rack shelf
MBU 125 Under-desk mounting kit
MBD 129 Through-desk mounting kit
PMK 100 Pole mount kit
60-190-10
60-604-11
60-190-01
60-604-02
70-077-01
70-077-02
70-217-01
70-563-03
70-725-01
70-530-02
70-396-11
70-397-11
60-502-01
42-103-03
42-070-03
42-120-13
22-150-03
22-153-03
26-627-25
26-627-35
26-627-50
26-627-100
PMK 350 Pole mount kit
EPS 1250 C External Power Supply Replacement kit
VC 50 Volume control wall plate
VCM 100 AAP Volume/mute - AAP
VCM 100 MAAP Volume/mute - MAAP
MLA VC10 Volume control module
SI 3CT LP Ceiling speakers
SI 26 CT Ceiling speakers
FF 120 T Ceiling speakers
SPK18/1000 Non-Plenum 1000' (300 m) spool
SPK18P/1000 Plenum 1000' (300 m) spool
SPK 18 Pre-cut speaker cable 25' (7.6 m)
SPK 18 Pre-cut speaker cable 35' (10.6 m)
SPK 18 Pre-cut speaker cable 50' (15.2 m)
SPK 18 Pre-cut speaker cable 100' (30.4 m)
MPA 401-70V • Specifications, Part Numbers, Accessories
A-4
Download from Www.Somanuals.com. All Manuals Search And Download.
MPA 401-70V
Appendix B
B
Mounting
Plenum.Placement
Tabletop.Placement
Rack.Mounting
Under-desk.Mounting
Through-desk.Mounting
Pole.Mounting
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting
Plenum Placement
The MPA 401-70V amplifier meets UL 2043 requirements for heat and smoke
release. It can be installed in the ceiling, out of sight, with reduced risk of theft.
Although the amplifier is plenum rated, the power supply provided with it
is not. The power supply must not be placed in the plenum space. Cables
to and from the amplifier must also be plenum rated.
C
Tabletop Placement
Attach the four provided rubber feet to the bottom of the unit and place it in any
convenient location.
Rack Mounting
UL guidelines for rack mounting
The following Underwriters Laboratories (UL) guidelines are relevant to the safe
installation of this product in a rack:
1. Elevated operating ambient temperature — If the unit is installed in a closed
or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore, install
the equipment in an environment compatible with the maximum ambient
temperature (TMA: +122 °F, +50 °C) specified by Extron.
2. Reduced air flow — Install the equipment in the rack so that the equipment
gets adequate air flow for safe operation.
3. Mechanical loading — Mount the equipment in the rack so that uneven
mechanical loading does not create a hazardous condition.
4. Circuit overloading — Connect the equipment to the supply circuit and
consider the effect that circuit overloading might have on overcurrent
protection and supply wiring. Appropriate consideration of the equipment
nameplate ratings should be used when addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of
rack-mounted equipment. Pay particular attention to supply connections other
than direct connections to the branch circuit (such as the use of power strips).
MPA 401-70V • Mounting
B-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Rack mounting procedure
The unit can be mounted on any of these optional rack systems:
RSU 126 — 6" deep 1U universal rack shelf kit (part # 60-190-10)
RSB 126 — 6" deep 1U basic rack shelf (part # 60-604-11)
RSU 129 — 9.5" deep 1U universal rack shelf kit (part # 60-190-01)
RSB 129 — 9.5" deep 1U basic rack shelf (part # 60-604-02)
To mount the scaler on a rack shelf, follow the instructions provided with the shelf
accessories.
Use only the two holes indicated in the diagram below for mounting the
MPA 401. The other four holes anchor stand-offs for the internal circuit
boards; using them may damage the amplifier and will not provide secure
mounting for the unit.
C
#4-40 Thread Thru
Rack Mounting
#4-40 Thread Thru
Rack Mounting
Under-desk Mounting
Mount the unit under a desk or podium, using the optional Extron MBU 125
under-desk mounting kit (part # 70-077-01) by following the instructions provided
with the MBU 125 kit.
Through-desk Mounting
Mount the unit through a desk or podium using the optional Extron MBD 129
through desk mounting kit (part # 70-077-02) by following the instructions
provided with the MBD 129 kit.
Pole Mounting
The amplifier can be mounted above a projector using either of these optional
Extron Pole Mounting Kits:
•
•
PMK 100 Pole mount kit (part # 70-217-01)
PMK 350 Pole mount kit (part # 70-563-03)
Follow the instructions provided with each kit.
MPA 401-70V • Mounting
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting, cont’d
MPA 401-70V • Mounting
B-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period
of three years from the date of purchase. In the event of malfunction during the warranty period
attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option,
repair or replace said products or components, to whatever extent it shall deem necessary to restore
said product to proper operating condition, provided that it is returned within the warranty period,
with proof of purchase and description of malfunction to:
USA, Canada, South America,
and Central America:
Extron Electronics
1001 East Ball Road
Anaheim, CA 92805
Japan: Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
U.S.A.
Europe, Africa, and the Middle East:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Middle East:
Extron Asia
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Singapore
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling
care, electrical or mechanical abuse, abnormal operating conditions or a modification to the product
that has not been authorized by Extron.
If it has been determined that the product is defective, please call Extron and ask for an Applications
Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.383.4400 (Asia), or 81.3.3511.7655 (Japan)
to receive an RA# (Return Authorization number). This will begin the repair process as quickly as
possible.
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of
loss or damage during shipment. Returned units must include the serial number and a description of
the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the
product and its quality, performance, merchantability, or fitness for any particular use. In no event
will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any
defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this
warranty may not apply to you.
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Checklist
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Select a suitable location and mount the amplifier (see appendix B).
Connect the remote input device (see page 2-3).
Adjust the Bass and Treble (see page 3-2).
Set up the remote control volume and mute options (see page 3-3).
Extron USA-West Extron USA-East Extron Europe
Extron Asia
Extron Japan
Extron China
Extron Middle East
Headquarters
+800.633.9876
+800.3987.6673
+800.7339.8766
+81.3.3511.7655
+81.3.3511.7656 FAX
+400.883.1568
+971.4.2991800
+971.4.2991880 FAX
Inside USA / Canada Only
Inside Europe Only
Inside Asia Only
Inside China Only
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
+31.33.453.4040
+31.33.453.4050 FAX
+65.6383.4400
+65.6383.4664 FAX
+86.21.3760.1568
+86.21.3760.1566 FAX
+1.714.491.1500
+1.714.491.1517 FAX
© 2010 Extron Electronics. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
|