Fujitsu Server TX200FT S2 User Manual

B7FH-3821-01EN-00  
TX200FT S2  
 
 
�  
�  
���  
■PRIMERGY TX200FT S2 Manuals  
Manuals for this server can be accessed from the section below of the PRIMERGY Document & Tool CD.  
[CD-ROM Drive] :\MANUAL\INDEX.PDF  
®
®
®
®
®
®
Manuals can be displayed using Acrobat Reader or Adobe Reader . If using Acrobat Reader , use version 4.0 or later.  
Checking the items  
supplied  
Checking "Safety Pre-  
cautions"  
1
2
Using the "Contents List", check that no supplied  
or attached items are missing. If any items are  
missing, contact an office listed in the "Contact  
Information.  
Before using this server, be sure to check the at-  
tached "Safety Precautions" guidelines.  
Also check the guidelines when connecting, installing  
internal options and setting up this server.  
Installing internal options  
3
If internal options have been purchased separately, install them before installing the Operating System.  
Points to note when installing  
internal options  
n
Available internal options and  
n
installation locations  
��  
 
When installing internal options, perform operations after  
reading the following manuals.  
 
�  
"Chapter 5 Installing Internal Options"  
�  
�  
"PRIMERGY ServerBooks"/  
"Supplement"  
When installing memory or hard disk, always install the  
same capacity of memory or hard disk to both enclo-  
sures.  
��  
 
�  
After installing internal options, check that the order and  
location of installation are correct and cables are cor-  
rectly attached.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Attach M5 rack nuts.  
Use 4U for each enclosure.  
Insert the rack nuts in the 2nd and 11th hole posi-  
tions, counting up from the base of the server, from  
inside of the rack bracket.  
Insert the server to install it to the rack.  
5
8
Insert the inner rail attached to the server to the  
grooves of the slide rail and slide the server to-  
wards the back.  
Hold the locks on the right and left of the slide rail  
pressed and slide the server even further into the  
rack.  
 
��  
 
Lock  
Lock  
�  
�  
�  
Attach the rail to the rack.  
6
Fasten the slide rail to the 1st and 3rd hole positions,  
counting up from the base of the server, with M5  
flathead screws and washers.  
 
Be careful when sliding the server into the rack and  
returning to the original position.  
 
There is a fear you may pinch your fingers or catch  
your clothing.  
 
�  
Fasten the server to the rack.  
Fasten using 4 thumbscrews (M5).  
9
 
 
�  
�  
�  
Install the second enclosure to the rack  
in the same way.  
10  
Pull the slide rails toward the front until  
they click into place.  
7
If a server or peripheral devices are not installed in the  
rack, install the attached blank panel.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting peripheral devices  
5
Peripheral devices, such as the keyboard and mouse, etc., are connected to the server in the following  
order.  
Connecting the LAN cables  
Connecting the display, keyboard and mouse  
l
l
�  
�����  
��  
����
���  
�  
 
�  
��  
�����  
 
 
Connecting power cables (when using UPS)  
l
���  
��  
 
��  
�  
���  
����  
�  
����  
��  
 
����  
����  
��  
�  
���  
�  
����  
�����  
����  
����  
���  
���  
��  
�  
���  
����  
���  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Filling in the pair identification label  
n
Fill in the label on the front of the server so that it is clear that FT1 and FT2 are a pair.  
Also, inform the support desk of the product ID and number of the FT1/FT2 when you contact them. Be sure to fill in this  
information.  
���  
���  
 
�  
��  
�  
��  
�  
Deciding required information before running mini-setup  
of the OS  
6
Before running mini-setup of the OS decide the following information.  
- User information (User and password)  
- Owner information  
- Validation interval at automatic shutdown (for UPS use only)  
- Network Configuration  
Decide and enter the values in the sheet below. Be sure to keep this sheet after entering.  
User information  
n
Item  
FT1 (CoServer1)  
FT2 (CoServer2)  
User name  
Password *1  
User name  
Password *1, 2  
User name  
Password  
Administrator  
Administrator  
FTvirtual Server system administrator  
CoServer system administrator  
UPS service system administrator *3  
PowerChute BusinessEdition user *4  
GAM (RAID administration) user  
User name  
Password  
User name  
Password *1, 2  
gamroot  
*1 : Do not leave the password blank.  
*2 : A separate password can be set for CoServer1 and CoServer2 but in order to avoid complicating various setting pro-  
cedures it is recommended that the same password be set for both.  
*3 : This user is not related in anyway to the Windows user account because it is set on PowerChute BusinessEdition.  
*4 : UPS service logon account.  
Owner information  
n
Item  
FTvirtual Server  
FT1 (CoServer1)  
FT2 (CoServer2)  
Name  
Organization  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Validation interval at automatic shutdown  
n
This setting required for the use of UPS.  
is  
For details about various settings, refer to "3.4 UPS Settings" in the "User's Guide". The numbers in brackets ( ) are setting  
examples.  
Item  
Actual Setting Parameters  
Time  
"Power Failure" - "When power fails, begin a shutdown  
procedure:" - "After UPS has been on battery for" in  
Device Properties.  
minutes  
(1 min)  
Validation interval from the power failure  
to the start of FTvirtual Server shutdown  
Validation interval from the start of FTvirtual Select Device properties "Shutdown Sequence" -  
minutes  
(3 mins)  
Server shutdown to the start of CoServer  
shutdown (Command file execution time)  
"Configure Shutdown Sequence" - "Next" - "OS" and  
then "Delay".  
Validation interval from the start of CoServer Select Device properties "Shutdown Sequence" -  
shutdown to UPS power off (time required for "Configure Shutdown Sequence" - "Next" - "OS" and  
minutes  
(1 minute  
30 seconds)  
OS shutdown)  
then "Duration".  
minutes  
seconds  
(5 minutes  
30 seconds)  
Total  
Network configuration  
n
CoServer Link1, CoServer Link2, Virtual Network1 and Virtual Network2 are internal network settings. Normally modifi-  
cations are not required.  
However, when there is a conflict with an external network, refer to "3.2 Network Functions" in the "User’s Guide" before  
setting. Figures in the brackets ( ) are default values.  
FTvirtual Server  
Item  
IP address  
Subnet mask  
Computer name  
Local area connection (FTvirtual Server LAN)  
Virtual Network1  
.
.
.
.
.
.
(255 . 255 . 255 . 252)  
(255 . 255 . 255 . 252)  
(192 . 168 . 181 . 81)  
(192 . 168 . 181 . 85)  
Virtual Network2  
CoServer1 (FT1)  
CoServer2 (FT2)  
Item  
IP address  
Subnet mask  
IP address  
Subnet mask  
Computer name  
CoServer Management  
(CoServer LAN)  
.
.
.
.
.
.
.
.
.
.
.
.
CoServer Link1  
CoServer Link2  
Virtual Network  
(
192 .168 .181 . 89  
192 .168 .181 . 93  
192 .168 .181 . 82  
)
)
)
(
(
(
255 .255 .255 .252  
)
)
(
192 .168 .181 . 90  
192 .168 .181 . 94)  
192 .168 .181 . 86)  
)
(
(
(
255 .255 .255 .252  
255 .255 .255 .252  
255 .255 .255 .252  
)
)
)
(
255 .255 .255 .252  
(
(
255 .255 .255 .252)  
(
When setting, the FTvirtual Server LAN adapter appears (Redirected 0) on the CoServer, but it is reserved because it is  
used by the FTvirtual Server.  
Do not bind internet protocol (TCP/IP) and do not set IP addresses or subnet masks to these adapters on the CoServer.  
Set the FTvirtual Server LAN IP address and the subnet mask on the FTvirtual Server.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Turning on the power and run mini-setup of each OS  
7
This section explains how to run mini-setup of CoServer1, CoServer2 and FTvirtual Server.  
To run mini-setup of FTvirtual Server, CoServer1 and 2 must already be run mini-setup.  
Run mini-setup in the following order.  
(1) Turn on the FT1 power and run mini-setup of CoServer1. Do not yet turn on the power of FT2.  
(2) Turn on the FT2 power and run mini-setup of CoServer2. The procedure is the same as for CoServer1.  
(3) Logon to CoServer1 and 2 and run mini-setup of FTvirtual Server.  
- CoServer1 and CoServer2 cannot be run mini-setup at the same time. After turning on the power of FT1 do not turn on  
the power of FT2 until CoServer1 has finished running mini-setup.  
- When an internal hard disk has been added or changing the size of C drive on the FTvirtual Server, before running mini-  
setup of each OS, perform recovery using the recovery CD.  
"7.7 Restoring Settings at the Time of Purchase (Recovery)"  
�  
Running mini-setup of the CoServer1  
n
- Adding/deleting devices become easier if the  
password for CoServer1 and CoServer2 are  
the same.  
- You must set a password. If not, an FT-system  
internal communication problem will occur.  
- Sometimes you cannot return even by press-  
ing [Back]. Check the parameters carefully and  
click [Next].  
Check that the FTvirtual Server LAN  
1
and CoServer LAN are not connected  
to the server and turn on the power  
supply of the peripheral devices.  
When connecting UPS check that UPS has a nor-  
mal power supply.  
Press the power switch on the FT1.  
2
After completing setup, the server restarts and start  
Windows OS.  
�  
��  
Logon to CoServer1.  
When the following screen appears enter "Endur-  
ance License Number" and click [OK].  
4
�  
�  
When the power is turned on, the server is checked  
using "Power On Self Test (POST)".  
If any abnormalities are detected by POST, error  
messages are displayed.  
"7.3 Error Messages"  
�  
- The Endurance License Number is printed in  
"
About Endurance License Number for Version  
After POST is finished, running mini-setup opera-  
tions automatically start.  
6.x supplied with the recovery CD.  
"
This number can be used for both CoServer1  
and CoServer2.  
- Depending on the environment sometimes a  
NumLock status occurs. In this case, press the  
NumLock key to unlock the lock and then enter  
Endurance License Number.  
When running mini-setup, enter the  
following parameters.  
Check the parameter setting values and click  
"Next".  
3
- After logging on to CoServer, a DOS prompt  
window appears at the same time as the "En-  
durance License Number" dialogue box ap-  
pears. However, do not perform operations  
such as closing DOS prompt windows.  
- Personalize Your Software  
(Name, organization)  
- Computer name & Administrator password  
- Date and Time Settings  
A message that recommends restarting appears.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Click [Yes].  
CoServer restarts.  
When the server restarts, press the  
power switch on the front of the server  
straight away and turn off the power  
supply.  
5
6
After restarting, the POST screen (or  
"PRIMERGY" logo) appears.  
Running mini-setup of the CoServer2  
n
The running mini-setup procedure is the same as for CoServer1. Press the power switch on the front of  
FT2 and turn on the power supply. For details about further operations, refer to " Running mini-setup  
n
of the CoServer1" and run mini-setup.  
Running mini-setup of the FTvirtual server  
n
Click [Start] " [All Programs] " [Mara-  
thon Endurance] " [Management Tasks]  
" [FTvirtual Server] " [Start] in CoServ-  
er1 in this order.  
The start window of Windows setup wizard ap-  
pears.  
Turn on the power supply of FT1 and  
FT2.  
1
4
�  
��  
Nothing is displayed on the Endurance FTvirtual  
Server Desktop momentarily, but this does not indi-  
cate an error. Please wait for a short while.  
Click [Next].  
Start setup. During setup enter the following pa-  
rameters. All other parameters are optional. After  
checking the parameter setting values, click [Next].  
5
After POST has finished, the OS selection window  
appears.  
- License Agreement  
- Personalize Your Software  
(Name, organization)  
- Computer name & Administrator password  
- Date and Time Settings  
 
�  
���  
��  
�����  
����  
�����  
When setup is complete, the FTvirtual Server re-  
starts and the logon window appears.  
Check that "Online Endurance CoServ-  
2
er" has been selected and press the  
[Enter] key.  
Logon to FTvirtual Server.  
Start Endurance Manager.  
6
7
The logon window appears.  
If the above operations are not performed, after a  
temporary stop (30 secs) it begins to operate as the  
"Online Endurance CoServer". It is fine to move on  
to the next operation.  
Click [Start] [All Programs] [Marathon En-  
"
"
durance] [Manager] to start Endurance Manager.  
"
Enter the administrators privileges  
password in FT1 and logon to CoServ-  
er1.  
3
The following window appears.  
If the FTvirtual Server LAN cable is not connected  
to the HUB, an error, as shown in the figure above,  
will be displayed but this does not indicate an error.  
Continue operations.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Click [OK] to close the [Component Prop-  
erties] window and Endurance Manager  
will end.  
Right-click on the FTvirtual Server icon  
and select "Properties".  
The [Component Properties] window appears.  
8
10  
11  
Set IP addresses for the following adapt-  
ers.  
Because DHCP is preset to automatically acquire  
IP addresses, if these IP addresses are acceptable  
the following procedures are not required.  
- CoServer1 "CoServer Management"  
- CoServer2 "CoServer Management"  
- FTvirtual Server "Local Area Connection"  
"Redirected0" in CoServer1 and CoServer 2 has  
been reserved for use by FTvirtual Server. Do not  
bind internet protocol (TCP/IP) to these adapters.  
Set the FTvirtual Server LAN IP address and the  
subnet mask on the FTvirtual Server.  
If optional devices have been added  
before running mini-setup of the OS,  
refer to the following and perform op-  
erations after expansion.  
- When a 5-inch internal backup device is add-  
ed  
12  
Select "FTvirtual Server" from the tree  
on the left, check "enabled" in "Auto-  
matic start" and click [Apply].  
9
"5.8.4 Procedure after Installing  
the Internal Backup Device"  
�  
A red warning message will appear in the top of the  
properties window but it just indicates a change in  
properties and will have no effect on operations.  
Turning the server off  
8
Perform shutdown in the FTvirtual Server window using the following procedures.  
Click [Start]  
"
[All Programs]  
thon Endurance] [Management  
Tasks] [Endurance Configuration]  
[Shutdown] in this order.  
"
[Mara-  
1
"
"
"
When turning on the server again after turning it off,  
wait for at least ten seconds and then press the power  
switch.  
If the server is turned on straight after being turned  
off, an error will occur that may be cause damage.  
A dialogue box for confirming shutdown will ap-  
pear.  
Click [OK].  
2
After shutting down FTvirtual Server, shutdown  
CoServer1 and CoServer2 and the power supply  
will be turned off automatically.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Connecting the remaining LAN cables  
9
After turning off the server, connect the remaining LAN cables as described below.  
In the FT-system, all FTvirtual Server LAN (application data transmission), CoServer Link, and CoServer LANs  
are used to control the system so it is important not to forget to connect the CoServer LAN cable to a HUB.  
●Connecting the LAN cables  
 
�����  
 
�  
Support and Service  
PRIMERGY information  
The latest PRIMERGY, driver, and software information is  
available at the address below. Use as necessary.  
11  
Pre-operation settings  
10  
l
After running mini-setup of the OS, refer to the  
following and perform FT-system settings.  
"Chapter 3 Pre-operation Settings"  
�  
Before requesting repairs  
l
When using UPS, perform UPS settings.  
If an error occurs in this server, refer to "User's Guide 7.2  
Troubleshooting". If problems can still not be solved, con-  
tact an office listed in the "Contact Information".  
When contacting the office listed in the "Contact Informa-  
tion", inform them of the product ID and manufactures  
number which are detailed on labels on the base of the  
server.  
"3.4 UPS setting"  
�  
For details about maintenance after operations have  
started, refer to "User's Guide Chapter 7 Operation  
and Maintenance".  
 
 
��
��
�  
�  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Also read the points to note about requesting repairs be-  
forehand in "User's Guide 7.10.2 Contacting Maintenaice  
Support".  
Print the "Configuration Sheets" - "Accident Sheet" and en-  
ter the checked information.  
Be careful not to lose this sheet, as you must provide this  
information when you contact an office listed in the "Con-  
tact Information" your maintenance engineer.  
- Service life of non-durable components  
The service life of non-durable components is decided based  
on the presumption that the server is used in an appropriate  
environment.  
The temperature of the operating environment is between  
10 and 35  
°C °C.  
However, the service life is calculated using  
25 as the average temperature so air conditioning should be  
°C  
used.  
Non-durable components  
l
- Non-durable component  
Depending on the environment and period of usage there will  
be non-durable components that require replacement within  
the warranty period. Customers who have signed up to hard-  
ware maintenance contract will be provided with replacement  
parts free of charge and will have higher priority for replace-  
ment.  
Item  
SCSI Array  
Description  
Regardless of how long power has been turned on  
Controller card or off, a replacement message will appear for non-  
battery durable components after 3 years.  
Customers not signed up to hardware maintenance contract  
will be charged for operation cost (including the maintenance  
parts) replacement separately.  
Recycling  
12  
When disposing of this server, contact an office listed in the "Contact Information".  
This server must be disposed of as industrial waste.  
Contact Information  
Australia:  
l
l
l
l
l
l
Philippines:  
Fujitsu Philippines, Inc.  
Tel: +63-2-812-4001  
Fax: +63-2-817-7576  
Address: 2nd Floor, United Life Building, A. Arnaiz  
Legaspi Village, Makati, Metro Manila Philippines  
Singapore:  
Fujitsu Asia Pte. Ltd.  
Tel: +65-6777-6577  
l
l
Fujitsu Australia Limited  
Tel: +61-2-9776-4555  
Fax: +61-2-9776-4556  
Address: 2 Julius Avenue (Cnr Delhi Road)  
North Ryde, Australia N.S.W. 2113  
China:  
Fujitsu (China) Holdings Co., Ltd.  
Tel: +86-21-5292-9889  
Fax: +86-21-5292-9566  
Address: 18F, Citic Square, 1168 West Nanjing Road Shanghai, China  
200041  
Fax: +65-6771-5502  
Address: 20, Science Park Road, #03-01 TeleTech Park,  
Singapore Science Park II, Singapore 117674  
Taiwan:  
Fujitsu Taiwan Limited  
Tel: +886-2-2311-2255  
Fax: +886-2-2311-2277  
Address: 19F, No.39, Section 1, Chung hwa Road Taipei, Taiwan  
Thailand:  
Fujitsu Systems Business (Thailand) Ltd.  
Tel: +66-2-500-1500  
Fax: +66-2-500-1555  
Address: 12th Floor, Olympia Thai Tower, 444 Rachadapisek Road  
Samsennok, Huaykwang, Bangkok, Thailand 10310  
Vietnam:  
Fujitsu Vietnam Limited  
Tel: +84-4-831-3895  
Hong Kong:  
Fujitsu Hong Kong Limited  
Tel: +852-2827-5780  
l
l
Fax: +852-2827-4724  
Address: 10/F., Lincoln House, 979 King's Road  
Taikoo Place, Island East, Hong Kong  
Indonesia:  
PT. Fujitsu Systems Indonesia Offices Headquarters  
Tel: +62-21-570-9330 (Hunting)  
Fax: +62-21-573-5150  
Address: Wisma Kyoei Prince 10th Floor Jl. Jend. Sudirman Kav 3-4  
Jakarta, Indonesia 10220  
Korea:  
Fujitsu Korea Ltd.  
Tel: +82-2-3787-6000  
Fax: +82-2-3787-6066  
Address: Susong Tower Building, 83-1 Susong-Dong  
Jongno-Gu, Seoul, Republic of Korea 110-140  
Malaysia:  
Fujitsu (Malaysia) Sdn. Bhd.  
Tel: +60-3-8318-3700  
l
l
Fax: +84-4-831-3898  
Address: Unit 802-8th floor, Fortuna Tower Hanoi 6B Lang ha Street,  
Ba dinh District, Hanoi Socialist Republic of Vietnam  
United States:  
Fujitsu Computer Systems Corporation  
Tel: +1-800-831-3183  
Fax: +1-408-496-0575  
Address: 1250 East Arques Avenue, Sunnyvale, CA USA 94088-3470  
Fax: +60-3-8318-8700  
Address: 1st Floor, No.3505 Jalan Technokrat 5  
63000 Cyberjaya, Selangor Darul Ehsan Malaysia  
For the latest information, refer to the Fujitsu PRIMERGY website (http://primergy.fujitsu.com).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
Data Backup  
To protect data stored in this device (including basic software and application software), perform backup and other necessary operations. Note that data protection is  
not guaranteed when repairs are performed. It is the customer's responsibility to maintain backup copies in advance.  
In case of data loss, Fujitsu assumes no liability for data maintenance or restoration and damages that occur as a result of the data loss for any reason, except for items  
covered under warranty.  
High Safety  
The Products are designed, developed and manufactured as contemplated or general use, including without limitation, general office use, personal use, household use,  
and ordinary industrial use, but are not designed, developed and manufactured as contemplated for use accompanying fatal risks or dangers that, unless extremely high  
safety is secured, could lead directly to death, personal injury, severe physical damage, or other loss (hereinafter "High Safety Required Use"), including without limi-  
tation, nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control  
in weapon system. You shall not use this Product without securing the sufficient safety required for the High Safety Required Use. If you wish to use this Product for  
High Safety Required Use, please consult with our sales representatives in charge before such use.  
Problems may occur with this device in the event of an instantaneous voltage drop of the power supply due to lightning, etc. To prevent an instantaneous voltage drop  
of the power supply, we recommend that you use an uninterruptible power supply system.  
Software License Agreement  
Please read the following terms and conditions before you use the software preinstalled in the server you purchased or the software attached to the server (hereinafter  
collectively "Software"). By using the Software, you are agreeing to be bound by all of the following terms and conditions. Notwithstanding the foregoing, if any soft-  
ware subject to any other terms and conditions than those of this agreement is preinstalled in or attached to the server as a part of Software, you shall comply with such  
other terms and conditions.  
I. License and Copyrights  
Fujitsu Limited (hereinafter "Fujitsu") grants you a limited, non-exclusive, license to:  
(i) use the Software solely on the server, which the Software is preinstalled in or is attached to.;  
(ii) copy the Software for installation and backup purpose; and  
(iii) embed the Software to other software, in whole or in part, in accordance with the procedure described in the applicable documentation.  
For the avoidance of doubt, you are only granted the right to use this Software and all copyright, title and other ownership rights to this Software and any derivative  
works thereof is retained by FUJITSU and/or its suppliers.  
II. Copies  
1. You may only copy the Software as set forth in Clause I (ii) and (iii) above. If you embed the Software in another software pursuant to Clause I (iii), you may not  
make copies of such software as so embedded other than one (1) backup copy unless expressly otherwise licensed by Fujitsu. If, however, a copy protection mechanism  
is implemented in the Software, you cannot and are prohibited from making any copies of the Software.  
2. You shall include all copyright notices and proprietary legends on all copies of the Software and shall not modify, delete or conceal such notices and legends.  
3. All terms and conditions contained herein shall apply to the copies of the Software.  
III. Assignment  
You may not assign the Software, except the case where you assign the Software with all materials related to the Software, including the media of the Software attached  
to the server, the documentation, and the backup copy, together with the server. Notwithstanding the foregoing, you may not rent, lease, sublicense, create lien against  
the Software.  
IV. Modification  
You may not modify or, except to the extent expressly permitted by applicable law, reverse engineer (including, without limitation, decompile and disassemble) the  
Software, and you may not permit any third party to do so.  
V. Limited Warranty  
1. You acknowledge that Fujitsu cannot guarantee that your use of the Software will be uninterrupted, that the Software will be error free or that all Software errors  
will be corrected. However, (i) within ninety (90) days following your acquisition of the server you notify the reseller from whom you have acquired the server of non-  
conformance of the Software to the description in the documentation, or (ii) within one (1) month following your acquisition of the server you notify the reseller from  
which you have acquired the server of physical defects of the media containing the Software, Fujitsu will, at its sole discretion, correct the non-conformance or provide  
you with information necessary to correct the non-conformance, or replace the defective media with new media. Only if you inform such reseller of your problem with  
the Software during the above mentioned warranty period and provide satisfactory evidence of the date you acquired the server Fujitsu will be obligated to honor this  
warranty.  
2. Except for Clause V Section 1, Fujitsu disclaims all other warranty, express or implied, and expressly disclaims any implied, including without limitation, allwar-  
ranty of merchantability, fitness for a particular purpose or non-infringement of third parties' rights. In no event will Fujitsu be liable for any direct, indirect, incidental  
or consequential damages (including, but not limited to, loss of profits, interruption of business, loss of business information, and other pecuniary damages) resulting  
from or arising out of the use or inability to use the Software even if Fujitsu has been advised of the possibility of such damages.  
3. Even if a part of the Software has been developed by a third party, the warranty and remedy for such part of the Software are limited to those provided for in Clause  
V Section1 and 2 above, and such third party shall have no liability for any claim arising out of the use, performance or non-conformance of the Software.  
VI . Law  
This Agreement and all matters arising out of or relating to this Agreement will be governed by the laws of Japan without giving effect to any choice of law rule.  
VII. High Safety  
These Software are designed, developed and manufactured as contemplated for general use, including without limitation, general office use, personal use, household  
use, and ordinary industrial use, but are not designed, developed and manufactured as contemplated for use accompanying fatal risks or dangers that, unless extremely  
high safety is secured, could lead directly to death, personal injury, severe physical damage, or other loss (hereinafter "High Safety Required Use"), including without  
limitation, nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch con-  
trol in weapon system. You shall not use this Software without securing the sufficient safety required for the High Safety Required Use.  
VII Export  
You shall comply fully with all relevant export laws and regulations with respect to this Software, including, but not limited to, the export laws and regulations of Ja-  
pan. Without limiting the generality of the foregoing, You will not export or transfer this Software, or any product thereof (including any your application program), to  
any destinations prohibited by any such laws and regulations.  
IV. Entire Agreement  
The terms and conditions hereof represent the complete agreement concerning this license between the parties and supersede all prior or contemporaneous written  
communications between them. In the event that any additional terms or conditions are provided in the accompanied documentation, you must also comply with such  
terms and conditions.  
Fujitsu Limited  
Microsoft, Windows, Windows Server are registered trademarks of the Microsoft Corporation in the USA and other countries.  
Adobe, Adobe Acrobat, Acrobat Reader are registered trademarks of Adobe Systems Incorporated.  
Endurance, Marathon Assured Availability, SplitSite, Marathon FTvirtual Server, and the Marathon logo are either registered trademarks or trademarks of  
Marathon Technologies Corporation in the United States and/or other countries.  
Other product names used are trademarks or registered trademarks of their respective manufacturers.  
Other products are copyrights of their respective manufacturers.  
All Rights Reserved, Copyright© FUJITSU LIMITED 2005  
Screen shot(s) reprinted with permission from Microsoft Corporation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Dynex TV Video Accessories DX WD1201 User Manual
Echo Trimmer PPFD 2400 User Manual
Edimax Technology Network Card LAN USB Adapter User Manual
Exido Scale 246 020 User Manual
Extreme Networks Switch 12800 Series User Manual
Frigidaire Washer FWX223LB User Manual
GE Appliance Trim Kit SESO732 User Manual
GE Monogram Range JBS08PIC User Manual
Golden Technologies Mobility Scooter GB106 User Manual
Goodman Mfg Air Conditioner 000 &12 User Manual