Fujitsu Scanner FI 6000NS User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Network Scanner fi-6000NS Getting Started  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright  
NetAdvantage 2005  
This product includes software developed by the  
University of California, Lawrence Berkeley  
Laboratory and its contributors.  
Copyright© 2002-2006 Infragistics, Inc.  
This product includes software developed by the  
Kungliga Tekniska Hogskolan and its  
contributors.  
This product includes software developed by Yen  
Yen Lim and North Dakota State University.  
LEADTOOLS for .NET  
Copyright© 2005 LEAD Technologies, Inc.  
WinPcap3.1  
Copyright © 1999 - 2005 NetGroup, Politecnico  
di Torino (Italy).  
Copyright © 2005 - 2006 CACE Technologies,  
Davis (California).  
Portions Copyright © 1990, 1991, 1992, 1993,  
1994, 1995, 1996, 1997 The Regents of the  
University of California.  
All rights reserved.  
All rights reserved.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
3. All advertising materials mentioning features  
or use of this software must display the  
3. Neither the name of the Politecnico di Torino,  
CACE Technologies nor the names of its  
contributors may be used to endorse or  
following acknowledgement: "This product  
includes software developed by the University  
of California, Berkeley and its contributors."  
promote products derived from this software  
without specific prior written permission.  
4. Neither the name of the University nor the  
names of its contributors may be used to  
endorse or promote products derived from this  
software without specific prior written  
permission.  
THIS SOFTWARE IS PROVIDED BY THE  
COPYRIGHT HOLDERS AND  
CONTRIBUTORS "AS IS" AND ANY  
EXPRESS OR IMPLIED WARRANTIES,  
INCLUDING, BUT NOT LIMITED TO, THE  
IMPLIED WARRANTIES OF  
THIS SOFTWARE IS PROVIDED BY THE  
INSTITUTE AND CONTRIBUTORS "AS IS"  
AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT  
LIMITED TO, THE IMPLIED WARRANTIES  
OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE ARE  
DISCLAIMED. IN NO EVENT SHALL THE  
REGENTS OR CONTRIBUTORS BE LIABLE  
FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING,  
BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS  
OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE ARE DISCLAIMED.  
IN NO EVENT SHALL THE COPYRIGHT  
OWNER OR CONTRIBUTORS BE LIABLE  
FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING,  
BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS  
OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
Network Scanner fi-6000NS Getting Started  
iii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
LIMITED TO, THE IMPLIED WARRANTIES  
OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE ARE  
DISCLAIMED. IN NO EVENT SHALL THE  
INSTITUTE OR CONTRIBUTORS BE LIABLE  
FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING,  
BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS  
OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
Portions Copyright © 1983 Regents of the  
University of California. All rights reserved.  
Redistribution and use in source and binary forms  
are permitted provided that the above copyright  
notice and this paragraph are duplicated in all such  
forms and that any documentation, advertising  
materials, and other materials related to such  
distribution and use acknowledge that the  
software was developed by the University of  
California, Berkeley. The name of the University  
may not be used to endorse or promote products  
derived from this software without specific prior  
written permission.  
THIS SOFTWARE IS PROVIDED "AS IS" AND  
WITHOUT ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, WITHOUT  
LIMITATION, THE IMPLIED WARRANTIES  
OF MERCHANTIBILITY AND FITNESS FOR  
A PARTICULAR PURPOSE.  
Portions Copyright © 1997 Yen Yen Lim and  
North Dakota State University. All rights  
reserved.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
Portions Copyright © 1995, 1996, 1997 Kungliga  
Tekniska Hogskolan (Royal Institute of  
Technology, Stockholm, Sweden). All rights  
reserved.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
3. All advertising materials mentioning features  
or use of this software must display the  
following acknowledgement: "This product  
includes software developed by Yen Yen Lim  
and North Dakota State University"  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
4. The name of the author may not be used to  
endorse or promote products derived from this  
software without specific prior written  
permission.  
3. All advertising materials mentioning features  
or use of this software must display the  
THIS SOFTWARE IS PROVIDED BY THE  
AUTHOR "AS IS" AND ANY EXPRESS OR  
IMPLIED WARRANTIES, INCLUDING, BUT  
NOT LIMITED TO, THE IMPLIED  
WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE  
ARE DISCLAIMED. IN NO EVENT SHALL  
THE AUTHOR BE LIABLE FOR ANY  
DIRECT, INDIRECT, INCIDENTAL, SPECIAL,  
EXEMPLARY, OR CONSEQUENTIAL  
DAMAGES (INCLUDING, BUT NOT LIMITED  
TO, PROCUREMENT OF SUBSTITUTE  
GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS  
following acknowledgement: "This product  
includes software developed by the Kungliga  
Tekniska Hogskolan and its contributors."  
4. Neither the name of the University nor the  
names of its contributors may be used to  
endorse or promote products derived from this  
software without specific prior written  
permission.  
THIS SOFTWARE IS PROVIDED BY THE  
INSTITUTE AND CONTRIBUTORS "AS IS"  
AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT  
iv  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
THIS SOFTWARE IS PROVIDED BY THE  
PROJECT AND CONTRIBUTORS "AS IS"  
AND ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, BUT NOT  
LIMITED TO, THE IMPLIED WARRANTIES  
OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE ARE  
DISCLAIMED. IN NO EVENT SHALL THE  
PROJECT OR CONTRIBUTORS BE LIABLE  
FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING,  
BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS  
OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
Portions Copyright © 1993 by Digital Equipment  
Corporation.  
Permission to use, copy, modify, and distribute  
this software for any purpose with or without fee  
is hereby granted, provided that the above  
copyright notice and this permission notice appear  
in all copies, and that the name of Digital  
Equipment Corporation not be used in advertising  
or publicity pertaining to distribution of the  
document or software without specific, written  
prior permission.  
THE SOFTWARE IS PROVIDED "AS IS" AND  
DIGITAL EQUIPMENT CORP. DISCLAIMS  
ALL WARRANTIES WITH REGARD TO THIS  
SOFTWARE, INCLUDING ALL IMPLIED  
WARRANTIES OF MERCHANTABILITY AND  
FITNESS. IN NO EVENT SHALL DIGITAL  
EQUIPMENT CORPORATION BE LIABLE  
FOR ANY SPECIAL, DIRECT, INDIRECT, OR  
CONSEQUENTIAL DAMAGES OR ANY  
DAMAGES WHATSOEVER RESULTING  
FROM LOSS OF USE, DATA OR PROFITS,  
WHETHER IN AN ACTION OF CONTRACT,  
NEGLIGENCE OR OTHER TORTIOUS  
ACTION, ARISING OUT OF OR IN  
Portions Copyright © 1996 Juniper Networks, Inc.  
All rights reserved.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that: (1) source code distributions retain  
the above copyright notice and this paragraph in  
its entirety, (2) distributions including binary code  
include the above copyright notice and this  
paragraph in its entirety in the documentation or  
other materials provided with the distribution.  
The name of Juniper Networks may not be used to  
endorse or promote products derived from this  
software without specific prior written permission.  
CONNECTION WITH THE USE OR  
PERFORMANCE OF THIS SOFTWARE.  
THIS SOFTWARE IS PROVIDED "AS IS" AND  
WITHOUT ANY EXPRESS OR IMPLIED  
WARRANTIES, INCLUDING, WITHOUT  
LIMITATION, THE IMPLIED WARRANTIES  
OF MERCHANTABILITY AND FITNESS FOR  
A PARTICULAR PURPOSE.  
Portions Copyright © 1995, 1996, 1997, 1998,  
and 1999 WIDE Project.  
All rights reserved.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
3. Neither the name of the project nor the names  
of its contributors may be used to endorse or  
promote products derived from this software  
without specific prior written permission.  
Network Scanner fi-6000NS Getting Started  
v
Download from Www.Somanuals.com. All Manuals Search And Download.  
Portions Copyright © 2001 Daniel Hartmeier All  
rights reserved.  
WinDump3.9.5  
Copyright © 1999 - 2005 NetGroup, Politecnico  
di Torino (Italy).  
Copyright © 2005 - 2006 CACE Technologies,  
Davis (California).  
All rights reserved.  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
Redistributions in binary form must reproduce  
the above copyright notice, this list of conditions  
and the following disclaimer in the  
Redistribution and use in source and binary forms,  
with or without modification, are permitted  
provided that the following conditions are met:  
1. Redistributions of source code must retain the  
above copyright notice, this list of conditions  
and the following disclaimer.  
documentation and/or other materials provided  
with the distribution.  
2. Redistributions in binary form must reproduce  
the above copyright notice, this list of  
conditions and the following disclaimer in the  
documentation and/or other materials  
provided with the distribution.  
THIS SOFTWARE IS PROVIDED BY THE  
COPYRIGHT HOLDERS AND  
CONTRIBUTOR "AS IS" AND ANY EXPRESS  
OR IMPLIED WARRANTIES, INCLUDING,  
BUT NOT LIMITED TO, THE IMPLIED  
WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE  
ARE DISCLAIMED. IN NO EVENT SHALL  
THE COPYRIGHT HOLDERS OR  
CONTRIBUTORS BE LIABLE FOR ANY  
DIRECT, INDIRECT, INCIDENTAL, SPECIAL,  
EXEMPLARY, OR CONSEQUENTIAL  
DAMAGES (INCLUDING, BUT NOT LIMITED  
TO, PROCUREMENT OF SUBSTITUTE  
GOODS OR SERVICES; LOSS OF USE, DATA,  
OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
3. Neither the name of the Politecnico di Torino,  
CACE Technologies nor the names of its  
contributors may be used to endorse or  
promote products derived from this software  
without specific prior written permission.  
THIS SOFTWARE IS PROVIDED BY THE  
COPYRIGHT HOLDERS AND  
CONTRIBUTORS "AS IS" AND ANY  
EXPRESS OR IMPLIED WARRANTIES,  
INCLUDING, BUT NOT LIMITED TO, THE  
IMPLIED WARRANTIES OF  
MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE ARE DISCLAIMED.  
IN NO EVENT SHALL THE COPYRIGHT  
OWNER OR CONTRIBUTORS BE LIABLE  
FOR ANY DIRECT, INDIRECT, INCIDENTAL,  
SPECIAL, EXEMPLARY, OR  
CONSEQUENTIAL DAMAGES (INCLUDING,  
BUT NOT LIMITED TO, PROCUREMENT OF  
SUBSTITUTE GOODS OR SERVICES; LOSS  
OF USE, DATA, OR PROFITS; OR BUSINESS  
INTERRUPTION) HOWEVER CAUSED AND  
ON ANY THEORY OF LIABILITY, WHETHER  
IN CONTRACT, STRICT LIABILITY, OR  
TORT (INCLUDING NEGLIGENCE OR  
OTHERWISE) ARISING IN ANY WAY OUT  
OF THE USE OF THIS SOFTWARE, EVEN IF  
ADVISED OF THE POSSIBILITY OF SUCH  
DAMAGE.  
Portions Copyright 1989 by Carnegie Mellon.  
Permission to use, copy, modify, and distribute  
this program for any purpose and without fee is  
hereby granted, provided that this copyright and  
permission notice appear on all copies and  
supporting documentation, the name of Carnegie  
Mellon not be used in advertising or publicity  
pertaining to distribution of the program without  
specific prior permission, and notice be given in  
supporting documentation that copying and  
distribution is by permission of Carnegie Mellon  
and Stanford University. Carnegie Mellon makes  
no representations about the suitability of this  
software for any purpose. It is provided "as is"  
without express or implied warranty.  
This product includes software developed by the  
University of California, Lawrence Berkeley  
Laboratory and its contributors.  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Thank you for purchasing the Network Scanner  
fi-6000NS.  
Canadian DOC Regulations  
This easy-to-operate network scanner may be used to  
scan documents for further use.  
This digital apparatus does not exceed the Class B  
limit for radio noise emissions from digital  
apparatus set out in the Radio interference  
Regulations of the Canadian Department of  
Communications.  
This Class B digital apparatus complies with  
Canadian ICES-003.  
This guide provides useful and detailed information on  
setting up, connecting, and caring for your scanner.  
The "Network Scanner fi-6000NS Operator's Guide"  
contains further information about scanner settings,  
scanner administration, and scanner operations, and may  
be used as a general reference.  
Please also read the Operator’s Guide for your  
reference.  
Le présent appareil numérique n'émet pas de  
parasites radioélectriques dépassant les limites  
applicables aux appareils numériques de la classe  
B et prescrites dans le Règlement sur le brouillage  
radioélectrique dictées par le Ministère des  
Communications du Canada.  
Regulatory Information  
Cet appareil numérique de la classe B est  
conforme _ la norme NMB-003 du Canada.  
FCC Declaration  
This equipment has been tested and found to  
comply with the limits for a Class B digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference in a  
residential installation. This equipment generates,  
uses, and can radiate radio frequency energy and,  
if not installed and used in accordance with the  
instruction manual, may cause harmful  
interference to radio communications. However,  
there is no guarantee that interference will not  
occur in a particular installation. If this equipment  
does cause harmful interference to radio or  
television reception, which can be determined by  
turning the equipment off and on, the user is  
encouraged to try to correct the interference by  
one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment  
and receiver.  
Bescheimigung des Herstellers /  
Importeurs  
Für den fi-6000NS wird folgendes bescheinigt:  
In ÅEereinsstimmung mit den Bestimmungen  
der EN45014(CE) funkentstört  
Maschinenlärminformationsverordnung 3.  
GPSGV: Der höchste Schalldruckpegel beträgt  
70 dB (A) oder weniger, gemäß EN ISO 7779.  
Note of Liability  
BEFORE USING THIS PRODUCT, PLEASE  
READ THIS MANUAL CAREFULLY. IF THIS  
PRODUCT IS NOT USED CORRECTLY,  
UNEXPECTED INJURY CAN OCCUR TO  
USERS OR BYSTANDERS.  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
located.  
Keep this manual in a safe place so that it can be  
easily referred to during use of this product.  
Consult your dealer or an experienced radio/TV  
While all efforts have been made to ensure the  
accuracy of all information in this manual, PFU  
assumes no liability to any party for any damage  
caused by errors or omissions or by statements of  
any kind in this manual, its updates or  
supplements, whether such errors are omissions or  
statements resulting from negligence, accidents,  
or any other cause. PFU further assumes no  
liability arising from the application or use of any  
product or system described herein; nor any  
liability for incidental or consequential damages  
arising from the use of this manual. PFU  
disclaims all warranties regarding the information  
contained herein, whether expressed, implied, or  
statutory.  
technician.  
FCC warning: Changes or modifications not  
expressly approved by the party responsible for  
compliance could void the user’s authority to  
operate the equipment.  
The use of a shielded interface cable is  
ATTENTION  
required to comply with the Class B limits  
of Part 15 of FCC rules.  
The length of the AC cable must be 2  
meters (6.6 feet) or less.  
Network Scanner fi-6000NS Getting Started  
vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Use in High-safety Applications  
Replacing Batteries  
This product has been designed and manufactured  
on the assumption that it will be used in office,  
personal, domestic, regular industrial, and  
general-purpose applications. It has not been  
designed and manufactured for use in applications  
(simply called "high-safety applications" from  
here on) that directly involve danger to life and  
health when a high degree of safety is required,  
for example, in the control of nuclear reactions at  
nuclear power facilities, automatic flight control  
of aircraft, air traffic control, operation control in  
mass-transport systems, medical equipment for  
sustaining life, and missile firing control in  
weapons systems, and when provisionally the  
safety in question is not ensured. The user should  
use this product with adopting measures for  
ensuring safety in such high-safety applications.  
PFU LIMITED assumes no liability whatsoever  
for damages arising from use of this product by  
the user in high-safety applications, and for any  
claims or compensation for damages by the user  
or a third party.  
This product has a battery (CMOS RAM battery)  
on board to retain data such as  
Warning  
Do not replace the battery yourself, as  
there is a risk of explosion if the wrong  
type is used. Please contact your  
maintenance engineer in charge when  
the battery runs low.  
Do not touch the battery. Never install  
or remove the battery by yourself.  
Doing so may cause electric shock or  
static electricity which can damage the  
device.  
Trademarks  
Microsoft and Windows are registered trademarks  
of Microsoft Corporation in the United States and/  
or other countries.  
Adobe, the Adobe logo, and Acrobat are either  
registered trademarks of Adobe Systems  
Incorporated in the United States and/or other  
countries.  
ABBYYTM FineReaderTM 7.x Engine © ABBYY  
Software House 2005.  
About the Use of Mercury  
Lamp(s) inside this product contain  
mercury and must be recycled or  
disposed of according to local, state, or  
g
H
OCR by ABBYY Software House. All rights  
reserved.  
federal laws.  
ABBYY, FineReader are trademarks of ABBYY  
Software House.  
Other product names are the trademarks or  
registered trademarks of the respective companies.  
To avoid unexpected injuries:  
Do not lick or consume the substance contained  
in the lamp.  
Do not breathe the chemical liquid contained in  
the scanner lamps.  
How Trademarks are Indicated in  
This Manual  
Do not incinerate, crush, or shred the lamps or  
scanner parts.  
References to operating systems (OS) and  
applications are indicated as follows:  
LCD Peculiarities  
The LCD backlight is a fluorescent tube that  
contains some mercury.  
Windows  
Windows® operating system  
Be aware that neither of the following is  
All the descriptions in this manual assume the  
usage of Adobe Acrobat bundled with this  
product. However, Adobe Acrobat may be  
upgraded without notice. If the descriptions differ  
from the screens actually displayed, refer to the  
Acrobat’s “Help”.  
considered a fault.  
Despite the advanced technologies used  
to produce the devices TFT color  
LCD's, the large number of pixels  
involved means that an occasional  
(always-on) bright dot or (always-off)  
dark dot may be visible.  
The characteristics of the LCD mean  
that there may be some variation in hue  
and intensity of colors across the screen.  
viii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Manufacturer  
Symbols Used in This Manual  
PFU LIMITED  
International Sales Dept., Imaging Business  
Division, Products Group  
Solid Square East Tower, 580 Horikawa-cho,  
Saiwai-ku, Kawasaki-shi Kanagawa 212-8563,  
Japan  
This symbol alerts operators to particularly  
important information. Be sure to read this  
information.  
ATTENTION  
Phone : (81-44) 540-4538  
This symbol alerts operators to helpful  
HINT  
All Rights Reserved, Copyright© PFU LIMITED 2007.  
advice regarding operation.  
About Maintenance  
The user must not perform repairs on this scanner.  
Contact your FUJITSU scanner dealer or an  
authorized FUJITSU scanner service provider for  
repairs to this product.  
A TRIANGLE symbol indicates that special  
care and attention is required.  
The drawing inside the triangle shows the  
specific caution.  
A CIRCLE with a diagonal line inside  
shows action which users may not perform.  
The drawing inside or under the circle  
shows the specific action that is not  
allowed.  
Warning Indications Used in This  
Manual  
This indication alerts operators  
to an operation that, if not strictly  
observed, may result in severe  
injury or death.  
Outline characters on a colored  
background show instructions users should  
follow.  
It may also include the drawing that shows  
the specific instruction.  
R
This indication alerts operators to  
an operation that, if not strictly  
observed, may result in safety  
hazards to personnel or damage  
to equipment.  
Warning Label  
The glass scanner windows inside the ADF  
can become hot when the scanner is used.  
Be careful not to touch the surface of the  
glass scanner windows.  
Do NOT remove from the scanner, stain or  
ATTENTION  
scratch the warning labels.  
Screen Examples in This Manual  
The screen examples in this manual are subject to  
change without notice in the interest of product  
improvement. If the actual displayed screen  
differs from the screen examples in this manual,  
operate by following the actual displayed screen  
while referring to the User's Manual of the scanner  
application you are using.  
Network Scanner fi-6000NS Getting Started  
ix  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Do not install the device in locations that  
has oil smoke, steam, humidity, and dust.  
Do not install the scanner in locations  
subject to oil smoke, steam, humidity, and  
dust. Doing so might cause a fire or electric  
shock.  
Do not damage the AC cable.  
A damaged AC cable may cause fire or  
electric shock. Do not place heavy objects  
on AC cables, or pull, bend, twist, heat,  
damage or modify AC cables.  
Do not use damaged AC cables or power  
plugs, or install any cables or power plugs  
to loose wall sockets.  
Turn the scanner OFF if it is damaged.  
If the scanner is damaged for any reason,  
turn the scanner off and unplug the power  
cable. Contact your FUJITSU scanner  
dealer or an authorized FUJITSU scanner  
service provider.  
Use only specified AC cables and  
connector cables.  
Do not put liquids inside the scanner.  
Do not insert or drop metal objects in to the  
scanner. Do not scan wet documents or  
documents with paper clips or staples. Do  
not splash or allow the scanner to get wet.  
Use only specified AC cables and connector  
cables. Failure to use the correct cables  
might cause electric shock and/or  
equipment failure.  
Please do not use the AC cable provided  
with this scanner for other devices, since  
this might cause equipment failure and  
other troubles or an electric shock.  
If foreign objects (water, small metal  
objects, liquids, etc.) get inside the scanner,  
immediately turn off the scanner and  
disconnect the power plug from the power  
outlet. Then, contact your FUJITSU scanner  
dealer or an authorized FUJITSU scanner  
service provider. Pay particular attention to  
this warning in households where there are  
small children.  
Use this scanner only at the indicated  
power voltage. Do not connect to  
multiple-power strips.  
Use this scanner only at the indicated  
power voltage and current. Improper power  
voltage and current might cause fire or  
electric shock. Do not connect to multiple-  
power strips.  
Do not touch the inside of the scanner  
unless necessary.  
Do not take apart or modify the scanner.  
The inside of the scanner contains high-  
voltage components. Touching these  
components might cause electric shock or  
fire.  
Do not touch the AC cable with wet  
hands.  
Do not touch the power plug with wet  
hands. Doing so might cause electric shock.  
Do not use the scanner if you smell a  
strange odor.  
If you detect heat coming from the device or  
detect other problems such as smoke,  
strange smells or noises, immediately turn  
off the scanner and then disconnect its  
power plug. Make sure that any smoke  
coming from it has stopped, before  
contacting your FUJITSU scanner dealer or  
an authorized FUJITSU scanner service  
provider.  
Wipe any dust from the power plug.  
Wipe off any dust from metal parts on the  
power plug or metal fittings with a soft, dry  
cloth. Accumulated dust might cause fire or  
electric shock.  
x
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before moving the scanner, disconnect  
the power plug from the power outlet.  
Do not install the scanner on unstable  
surfaces.  
Do not move the scanner with the power  
and interface cables connected as this can  
damage the cables, which can later cause  
fire, electric shock as well as injury.  
Before moving the scanner, be sure to  
disconnect the power plug from the power  
outlet, and all other data cables.  
Make sure that the scanner is installed on a  
flat, level surface and that none of its parts  
extend beyond the surface top, such as a  
desk or table. Do not install the scanner on  
unstable surfaces. Install the scanner on a  
level surface that is free of vibration to  
prevent it from falling.  
Make sure that the floor is free of any  
obstructions.  
Install the scanner on a strong surface that  
will support the weight of the scanner and  
other devices.  
Protect the scanner from static electricity.  
Install the scanner away from strong  
magnetic fields and other sources of  
electronic noise. Also, protect the scanner  
against any static electricity, which can  
cause the scanner to malfunction.  
Do not block the ventilation ports.  
Do not block the ventilation ports. Blocking  
the ventilation ports generates heat inside  
of scanner, which may result in fire or  
scanner failure.  
Do not use aerosol sprays near the  
scanner.  
Do not place heavy objects or climb on  
top of the scanner.  
Do not use aerosol sprays to clean the  
scanner. Aerosol sprays can blow dirt and  
dust inside the scanner, resulting in scanner  
failure or malfunction.  
Do not place heavy objects on the scanner  
or use the scanner's surface top to perform  
other work. Improper installation might  
cause injuries and equipment failure.  
Disconnect the power plug from the  
power outlet when the scanner is not used  
for a long period of time.  
Firmly insert the power plug.  
Firmly insert the power plug as far it can go  
into the power outlet.  
When the scanner is not going to be used  
for a long period of time, be sure to  
disconnect the power plug from the power  
outlet for safety.  
Avoid any contact when scanner is in use.  
Do not install the scanner in the direct  
sunlight.  
Avoid touching any scanner mechanism  
during scanning since this may cause  
injuries.  
Do not install the scanner under direct  
sunlight or near heating apparatus. Doing  
so might cause excessive heat to build up  
inside the scanner, which can cause  
scanner trouble or even fire. Install the  
scanner in a well-ventilated location.  
Do not use the scanner immediately after  
moving it from a cold place into a warm  
room.  
Do not use the device immediately after  
moving it from a cold place into a warm  
room. Condensation may occur, which  
might lead to scanning errors. Let the  
device dry about one or two hours before  
you use it.  
Before moving the scanner, make sure the  
shipping lock is locked.  
When moving the scanner, be sure to lock  
the shipping lock in order to prevent  
damages to the scanner.  
Network Scanner fi-6000NS Getting Started  
xi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
xii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 Scanner Features  
1.1 Scanner Features  
This easy-to-operate network scanner may be used to scan documents for further use:  
Scanned document files can be sent as an e-mail attachment.  
Scanned document files can be sent by fax.  
Scanned document files can be saved in a network folder.  
The scanner has the following security features.  
Login authentication can restrict user access.  
Scans can be converted to password protected PDF files.  
Internet  
Send e-mail  
SMTP Server  
Scanner Settings  
PC  
Orignal  
Document  
Fax Server  
Send Fax  
Scanned Data  
Scanner  
User  
Authentication  
LDAP Server  
File Server  
Save  
The scanner functions available after login vary in the following ways for different types of user:  
Administrator  
Can setup and manage the scanner. The administrator can operate via the scanner's touch  
panel or via a computer web browser.  
For login via the scanner's touch panel, scanner setup and management operations are possible.  
For login via the web interface, scanner setup, management, and update operations are possible.  
Regular User  
Can scan documents and then send or save the resulting data.  
For more details, refer to the "Network Scanner fi-6000NS Operator’s Guide".  
Network Scanner fi-6000NS Getting Started  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
1.2 From Arrival through Operation  
Check package  
Setup scanner  
Setup network  
is the "Network Scanner fi-6000NS Operator’s Guide".  
Download manual  
Perform scan test  
User function settings  
Operation  
Refer to "Network Scanner fi-6000NS Operator's Guide".  
Refer to "Network Scanner fi-6000NS Operator's Guide".  
1.3 Checking the Contents of the Scanner Package  
When you open the scanner package, please handle the main unit and its attachments carefully.  
Make sure the scanner package contains all the parts listed in the package contents list that is included in the package  
box.  
If any parts are missing or defective, contact your FUJITSU scanner dealer or an authorized FUJITSU scanner service  
provider.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Removable Parts  
1.4 Names and Functions of  
Parts  
Parts that can be removed from the scanner are  
displayed below.  
This section describes the scanner parts and their  
functions.  
Separate shaft  
and roller  
Front  
Pad assembly  
Pick roller  
Sheet guide  
ADF  
Glass scanner windows  
Rear  
Network Scanner fi-6000NS Getting Started  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2 Setting up the Scanner  
2.1 Space Requirements  
The following space is required to set up the scanner:  
Depth: 700mm  
Width: 400mm  
Height: 500mm  
2.2 Installing the Scanner  
2. Connect the AC adapter connector to the  
scanner's DC inlet.  
When lifting the scanner, always  
hold it by the indentations on the  
bottom of each side to ensure a  
stable grip.  
Holding the scanner in any other  
way may cause it to be dropped  
or damaged.  
3. Connect the LAN cable to the LAN connector.  
1. Place the scanner at its installation site.  
2. Attach the ADF paper chute.  
4. Attach the back cover.  
Hold the ADF paper chute and insert its tabs into  
the corresponding slots in the scanner as shown in  
the following figure.  
The side guides of the ADF paper chute should  
face up.  
Attach the cover with the connected AC cable or  
LAN cable protruding out of the lower part of  
the cover.  
Tab  
5. Connect the other end of the LAN cable to the  
network hub.  
2.3 Connecting the Cables  
6. Insert the AC cable into a power outlet.  
1. Connect the AC cable to the AC adapter.  
The power is connected but the scanner is not  
yet ready for operation.  
Use only the AC adapter provided by the  
ATTENTION  
manufacturer.  
Continue setting up the network.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Chapter 3 Setting up for Network Use  
3. Enter the password.  
3.1 Logging in  
Password is case sensitive.  
Enter "password" here.  
To set up the network connection, you must login as the  
administrator. The user name and initial password for  
the administrator are as follows:  
4. Press the [Login] button.  
User Name: admin  
Password: password  
If the administrator name and password are  
valid, the "System Settings" screen appears.  
1. Press the startup button.  
3.2 Changing the Administrator  
Password  
The administrator password can be changed.  
1. Select the [System Settings] tab on the top  
menu.  
Startup button  
2. Press the [Down] button on the left side menu.  
Scroll the left side menu down until the  
[Admin Password] tab appears.  
After system startup, the "Login" screen  
appears..  
3. Select the [Admin Password] tab on the left  
side menu.  
After turning the power off, wait for at  
ATTENTION  
least ten seconds before turning the  
power back on again.  
If touch panel responses seem out of  
HINT  
alignment with the positions of objects on  
the LCD screen, calibrate the screen.  
2. Enter the user name.  
The "Admin Password" screen appears.  
User name is case sensitive. Enter "admin" here.  
4. Enter the "Current Password", "New  
Password", and "Confirm New Password".  
Passwords must be between 7 and 127 characters  
long.  
Alphanumeric characters (case sensitive) and  
symbols may be entered.  
5. Press the [OK] button.  
The new admin password is set.  
Network Scanner fi-6000NS Getting Started  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
3.3 Setting the Scanner Name  
If the scanner name is the same as one  
already in use, network communication  
problems will occur. In this case, try the  
following steps:  
HINT  
A scanner name may be set to provide a network alias  
for the device.  
1. Disconnect the LAN cable and turn the  
scanner off.  
Do not use a name that is already  
being used in the network.  
Name duplication will cause a network  
connection error.  
2. Reboot the scanner with the LAN cable  
still disconnected, and enter a non-  
duplicate scanner name.  
ATTENTION  
3. Reboot the scanner again.  
4. Re-connect the LAN cable to the scanner.  
Restart may be performed after all necessary settings  
have been completed.  
1. Select the [System Settings] tab on the top  
menu.  
Continue with the Region/Timezone settings.  
2. Select the [Scanner Name] tab on the left side  
menu.  
3.4 Setting the Region/Timezone  
1. Select the [System Settings] tab on the top  
menu.  
2. Select the [Region/Timezone] tab on the left  
side menu.  
The "Scanner Name" screen appears.  
3. Enter a scanner name.  
Scanner names may be up to 15 characters long.  
Use only alphanumeric characters (case sensitive)  
and hyphens.  
Scanner names cannot consist of numbers only.  
The "Region/Timezone" screen appears.  
4. Press the [OK] button.  
3. Press the [List] button for the "Timezone" input  
field.  
The restart confirmation screen appears.  
5. Press the [Later] button.  
The default timezone is "(GMT+09:00) Osaka,  
Sapporo, Tokyo".  
A list of timezones appears.  
4. Select a timezone.  
The current scanner name, or changed scanner  
name after next restart, is displayed.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Select whether "Daylight Savings Time" should  
be on or off.  
3. Set the scanner's IP address. This may be  
done automatically, by pressing the DHCP [On]  
button.  
This option is not shown for timezones where  
daylight savings time is not used.  
The IP address may also be set manually, by  
pressing the DHCP [Off] button and entering  
the following numerical addresses:  
6. Press the [OK] button.  
IP Address  
Subnet Mask  
Default gateway  
The Region/Timezone is set.  
Continue with IP address/DHCP settings.  
3.5 Setting the IP Address/DHCP  
An IP address must be set in order to connect the  
scanner to a network.  
Do not use an IP address that already  
ATTENTION  
exists in the network.  
IP address duplication will cause an  
error during setup.  
1. Select the [Network Settings] tab on the top  
menu.  
4. Press the [OK] button.  
The information entered is set.  
2. Select the [IP Address] tab on the left side  
menu.  
If the IP address is the same as one  
HINT  
already in use, network communication  
problems will occur. In this case, try the  
following steps:  
1. Disconnect the LAN cable and turn the  
scanner off.  
2. Reboot the scanner with the LAN cable  
still disconnected, and enter a non-  
duplicate IP address.  
3. Re-connect the LAN cable to the scanner.  
When DHCP is set to "On", the following  
settings are assigned by the DHCP:  
IP Address  
Subnet Mask  
Default Gateway  
DNS Server  
WINS Server  
The IP address/DHCP screen appears.  
Even if DNS or WINS server is set, priority  
is given to the scanner settings over the  
DHCP settings.  
Continue with the DNS settings.  
Network Scanner fi-6000NS Getting Started  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
3.6 Setting the DNS Server  
3.7 Setting the WINS Server  
A primary DNS and secondary DNS can be set.  
A primary WINS and secondary WINS can be set.  
1. Select the [Network Settings] tab on the top  
menu.  
1. Select the [Network Settings] tab on the top  
menu.  
2. Select the [DNS Server] tab on the left side  
menu.  
2. Select the [WINS Server] tab on the left side  
menu.  
The "WINS Server" screen appears.  
The "DNS Server" screen appears.  
3. Enter the following numerical addresses:  
3. Enter the following numerical addresses:  
Primary WINS  
Primary DNS  
Secondary WINS  
Secondary DNS  
If a WINS server setting is not required, enter  
"0.0.0.0".  
If a DNS server setting is not required, enter  
"0.0.0.0".  
A Secondary WINS cannot be set  
without a Primary WINS.  
A Secondary DNS cannot be set  
without a Primary DNS.  
ATTENTION  
ATTENTION  
4. Press the [OK] button.  
4. Press the [OK] button.  
The information entered is set.  
The information entered is set.  
Continue with the WINS settings.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
6. Press the [Ping] button.  
3.8 Checking the Network  
Connection  
A ping test is performed and the results are  
displayed. If the result shows "Lost=0 (0%  
loss)", the network connection is functioning  
normally. For any other result, refer to  
The network connection may be checked by performing  
a ping test.  
1. Select the [Network Settings] tab on the top  
menu.  
2. Press the [Down] button on the left side menu.  
Scroll the left side menu down until the [Ping]  
tab appears.  
3. Select the [Ping] tab on the left side menu.  
After performing all settings, restart the system.  
3.9 Restarting the System  
1. Press the [Logout] button.  
The restart confirmation screen appears.  
The "Ping" screen appears.  
2. Press the [Restart] button.  
4. Select whether to set a server name or IP  
address.  
The [Server Name] and [IP Address] buttons  
cannot both be selected.  
5. Enter the target server name or IP addresses  
(selected in Step 4).  
If the [Server Name] button is selected:  
Enter a Fully Qualified Domain Name (FQDN)  
or server name in the input field. This may be up  
to 255 characters long.  
The scanner restarts, and the "Login" screen  
If the [IP Address] button is selected:  
appears.  
Enter a numerical IP address.  
Next, download the "Network Scanner fi-6000NS  
Operator's Guide".  
Network Scanner fi-6000NS Getting Started  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Chapter 4 Downloading the Manual  
In addition to this "Getting Started" guide, a "Network  
Scanner fi-6000NS Operator's Guide" is also available.  
The "Network Scanner fi-6000NS Operator's Guide"  
contains information about scanner settings, scanner  
administration, and scanner operations.  
2. Press the [Download Manual] button.  
Consult this manual when using the scanner.  
Login as the administrator via the web interface to  
download the "Network Scanner fi-6000NS Operator's  
Guide".  
The download procedure is as follows:  
To download the manual from the scanner, the  
following requirements apply:  
Software  
English versions:  
Microsoft® Internet Explorer 6 SP2  
or later  
The "File Download" screen appears.  
Adobe® Reader® (*)  
Any Windows® operating system  
3. Press the [Save] button.  
which supports the above software  
Hardware Any client PC which runs the  
supported software  
XGA monitor or better  
LAN cable  
* Adobe® Reader® can be downloaded from the  
following site.  
The "Save As" window appears.  
4. Select a folder and enter a file name.  
1. Specify the scanner name as a URL in the web  
browser's location bar.  
For example, when the scanner name is  
"SCAN001":  
use "http://SCAN001/"  
For URL's, an IP address can be set instead of a  
scanner name. If the IP address is  
xxx.xxx.xxx.xxx, the specified URL is  
http://xxx.xxx.xxx.xxx/.  
The "Login" screen appears on the web  
5. Press the [Save] button.  
browser.  
The file is saved.  
The "Network Scanner fi-6000NS Operator's Guide" is  
a PDF file, and can be viewed with Adobe® Reader®.  
Next, perform a scan test.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Performing a Scan Test  
Perform a scan test to determine if the scanner is  
working properly. Login as a regular user to perform the  
scan test.  
4. Select the [Maintenance] button on the "Main  
Menu" screen.  
1. Load the documents to be test scanned.  
S i d e  
R e v e r s e  
The "Login" screen appears.  
The "Maintenance" screen appears.  
2. On the "Login" screen, enter a "User Name"  
and "Password".  
5. Press the [Scan Test] button.  
Enter "guest" for both fields here.  
The scan settings information for the scan test  
is displayed.  
3. Press the [Login] button.  
6. Press the [Scan] button.  
If the user name and password are valid, the  
"Main Menu" screen appears.  
Scanning starts. When the scan has  
completed, the "Scan Viewer" opens.  
Network Scanner fi-6000NS Getting Started  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
If a multifeed is detected  
7. Check the scanned data.  
Message  
Feed Error: Document(s) may not match the set  
paper size, ADF may have grabbed more than  
one sheet, or documents may not be suitable for  
scanning. Remove the documents from the ADF,  
check them and try again. If problem persists,  
consult the manual.  
Action  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. Remove the  
document for which multifeed was detected, and  
try the scan test again.  
If a paper jam occurs  
Message  
Paper jam has occurred. Remove the documents  
from the ADF and try again.  
Action  
8. Press the [OK] button.  
The "Maintenance" screen is shown again.  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. If the "Scan  
Viewer" screen appears with partially scanned  
data, just click the [OK] button. Remove any  
unscanned documents from the ADF. Open the  
scanner's top cover, remove the jammed  
document from the scanner, and close the  
scanner's top cover. From the "Maintenance"  
screen, try the test scan again.  
If Scanning Completes  
Successfully  
Continue with the setting procedures described in  
Chapter 1 of the "Network Scanner fi-6000NS  
Operator's Guide".  
System settings or user data can be  
HINT  
backed up from [Maintenance], [User Data  
If a USB cable becomes disconnected  
Store] or [System Settings File]. This can  
only be performed via Web interface.  
Backup should be performed regularly.  
For more details, refer to the "Network  
Scanner fi-6000NS Operator's Guide".  
Message  
Scanner initialization has failed. Try turning the  
power off and back on again. The administrator  
should contact the FUJITSU scanner dealer or  
an authorized FUJITSU scanner service provider  
for help.  
Action  
If Scanning does not Complete  
Successfully  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. Check that  
all cables are firmly connected, and try the scan  
test again.  
If the top cover is open  
Message  
Top cover may be open. Close the top cover,  
reload the documents and try again.  
Action  
If an error occurs  
Message  
An error has occurred. Try turning the power off  
and back on again. The administrator should  
contact the FUJITSU scanner dealer or an  
authorized FUJITSU scanner service provider  
for help.  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. Close the  
top cover, and try the scan test again.  
If no document is loaded  
Message  
Document not found. Load a document into the  
Action  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. Contact your  
FUJITSU scanner dealer or an authorized  
FUJITSU scanner service provider.  
ADF, making sure the side guides are adjusted  
correctly and try again.  
Action  
Click the [OK] button on the error dialog to  
return to the "Maintenance" screen. Load a  
document, and try the scan test again.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix A Calibrating the Touch Panel  
This should be done if and when the touch panel  
responses seem out of alignment with the positions of  
objects on the LCD screen.  
The keyboard may also be used on the  
calibration screen:  
HINT  
Press the [Home] key to jump straight to  
the post-calibration test screen.  
1. Login as the administrator.  
Use the arrow keys to move the "+" to a  
different calibration point. This allows a  
bad touch to be redone.  
For details, refer to "3.1 Logging in" (page 5).  
The "System Settings" screen appears.  
Press the [Esc] key to stop the calibration  
process and return to the "Screen  
Calibration" screen.  
2. Select the [System Settings] tab on the top  
menu.  
Press the [Enter] key to close the error  
dialog. (Not normally needed.)  
3. Select the [Screen Calibration] tab on the left  
side menu.  
The "Calibration Screen" appears.  
Repeat until the test screen appears, with the  
following "Calibration" dialog box:  
4. Press the [Calibrate Screen] button.  
6. Trace a line on the screen with your fingertip.  
A corresponding line will appear on-screen.  
If the line does not appear correctly, press the  
[Calib screen] button to return to Step 5.  
If the screen becomes cluttered, press the  
[CLR screen] button to remove all the lines.  
Press the [Cursor on/off] button to toggle  
ATTENTION  
the mouse cursor between its "visible"  
and "hidden" states.  
A blank calibration screen appears, with a red  
"+" (adjustment mark) in the top-left corner.  
7. When you are satisfied with the touch screen  
response, press the [Update] button.  
5. Touch the "+" with your fingertip.  
After being touched, the "+" will move to  
the next calibration position. Each time  
it stops, touch it again.  
This saves the current calibration data,  
completing the calibration process, and  
returns you to the "Screen Calibration"  
screen.  
If the calibration is not performed  
ATTENTION  
carefully, or the [Enter] key is pressed  
before all the calibration points have been  
touched, the following error message may  
appear:  
Parameter Error. Please input, again.  
Press the [Enter] key to dismiss the error  
dialog, and perform the calibration again,  
being careful to touch each calibration  
point accurately.  
Network Scanner fi-6000NS Getting Started  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Appendix B Scanner Care  
The glass scanner windows  
inside the ADF can become hot  
when the scanner is used.  
The scanner must be cleaned more  
frequently when the following types of  
documents are used:  
ATTENTION  
Before cleaning inside the  
Coated paper  
scanner or replacing any parts,  
turn off the power, unplug the AC  
adapter from the outlet, and wait  
for at least 15 minutes.  
Documents with large areas of printing  
Chemically treated paper such as  
carbonless paper  
Paper containing large amounts of  
calcium carbonate filler  
The power does not need to be  
turned off when cleaning the  
feed rollers.  
Documents written in pencil  
Documents with insufficiently fused  
toner  
Cleaning Materials  
For more details, refer to "5.2 Cleaning the ADF " in the  
"Network Scanner fi-6000NS Operator's Guide".  
Cleaning  
Materials  
Parts No.  
Remarks  
1 bottle  
Moisten the cloth with  
this fluid and use to  
wipe parts clean.(*)  
Cleaning the LCD Touch Panel  
Cleaner F1  
(or isopropyl  
alcohol)  
PA03950-  
0352  
To prevent the touch panel screen from becoming dirty,  
it should be regularly cleaned with a soft, dry cloth.  
Take care when cleaning the touch panel. It can be  
easily damaged, and should never be scratched or  
banged with hard objects.  
Soft, dry cloth  
Any commercially available lint-free  
product  
* To obtain Cleaner F1, contact your FUJITSU dealer or  
an authorized FUJITSU scanner service provider.  
Always use a dry (not damp) cloth to  
ATTENTION  
clean the screen. Do not apply Cleaner  
F1.  
If dust is allowed to collect and harden  
around the frame of the screen, it can  
cause the touch panel to malfunction.  
Cleaning Method  
Clean the ADF with a soft cloth moistened with cleaner  
F1.  
Which Parts and When  
Cleaning the Keyboard  
Clean all parts after every 1,000 sheets scanned.  
Pad assembly  
To prevent the keyboard from becoming dirty, it should  
also be regularly cleaned with a soft, dry cloth.  
Feed rollers  
Pick roller  
Idler rollers  
Glass scanner windows  
Ultrasonic sensor  
Always use a dry (not damp) cloth to  
clean the keyboard. Do not apply  
Cleaner F1.  
ATTENTION  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix C Replacing Consumable Parts  
The glass scanner windows  
inside the ADF can become hot  
when the scanner is used.  
Use only the PFU LIMITED parts  
ATTENTION  
specified. Do not use consumable parts  
made by other manufacturers.  
Before cleaning inside the  
scanner or replacing any parts,  
turn off the power, unplug the AC  
adapter from the outlet, and wait  
for at least 15 minutes.  
The following diagram shows the locations of the  
consumable parts in the scanner. For more details, refer  
to "5.5 Replacing Parts" in the "Network Scanner  
fi-6000NS Operator's Guide".  
Pad Assembly (PAD ASSY)  
Replacement Part No. and  
Standard Replacement Cycles  
The usage count of consumable parts can be checked in  
administrator mode on the "Usage Status" screen.  
Pick Roller  
Pick Roller  
When parts need to be replaced soon, the "Status"  
information field becomes orange. When parts need to  
be replaced immediately, the "Status" information field  
becomes red.  
The following table specifies the replacement part  
numbers and the standard replacement cycles.  
Part name  
Replacement cycle  
Pad Assembly  
(PA03289-0111)  
After every 50,000 sheets scanned or  
once a year  
Pick Roller  
(PA03289-0001)  
After every 100,000 sheets scanned  
or once a year  
To obtain these parts, contact your FUJITSU dealer or  
an authorized FUJITSU scanner service provider.  
These replacement cycles are rough guidelines when  
Pick Roller's Shaft  
using 64 g/m2 (17 lb) A4/Letter woodfree or wood  
containing paper. They may vary according to the type  
of documents scanned, scanner usage, and cleaning  
frequency.  
Network Scanner fi-6000NS Getting Started  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Appendix D Network Connection Troubleshooting  
Checking Basic Network Operation with a Ping Test  
If a network connection is not possible, refer to "3.8 Checking the Network Connection" (page 9) for ping results and  
how to deal with them.  
Server  
name  
setting  
Connection  
Result  
Action  
status  
"Ping statistics" shows "Lost=0  
(0% loss)"  
IP address /  
server name  
None  
OK  
NG  
"Ping statistics" shows "Lost=4  
(100% loss)"  
IP address /  
server name  
Check that the ping target IP address or server name is  
correct.  
IP Address  
If the ping target IP address is correct, refer to "Failure  
(page 17) for further solutions.  
Server name On the "Network Status" screen, change [Link speed /  
Duplex mode] from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [Down] button on the left side menu.  
3. Select the [Network Status] tab on the left side  
menu.  
4. On the "Network Status" screen, select [Link  
Speed/Duplex Mode].  
5. Press the [OK] button.  
"Ping statistics" shows "Lost=N NG  
(1 to 99% loss)"  
IP address /  
server name  
There may be a problem with the quality of the LAN  
cable. Replace the LAN cable and try again.  
IP address /  
server name  
On the "Network Status" screen, change [Link speed /  
Duplex mode] from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [Down] button on the left side menu.  
3. Select the [Network Status] tab on the left side  
menu.  
4. On the "Network Status" screen, select [Link  
Speed/Duplex Mode].  
5. Press the [OK] button.  
"Hardware error"  
NG  
NG  
IP address /  
server name  
The LAN cable may have become disconnected during  
the Ping test. Check the status of the LAN cable and try  
again.  
"Ping request could not find  
host xxx.xxx.xxx. Please check  
the name and try again."  
Server name Check that the ping target server name is correct.  
Check that the DNS server or WINS server settings are  
correct.  
If the ping target server name is correct, refer to "Failure  
to Connect to a Remote Computer using its Server  
Name" (page 18) for further solutions.  
OK: Connection is operating normally. NG: Connection is faulty.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Failure to Connect to a Remote Computer using its IP Address  
If a remote computer cannot be connected to using its IP address, and does not respond to a ping test, try the following  
steps:  
No.  
Problem  
Action  
1
Connection error between a remote computer  
and the scanner, or problem with the LAN  
cable.  
Check that the LAN cable has been attached to both the scanner and  
remote computer correctly.  
If the remote computer is connected using a LAN cable (straight  
type), in case auto-mdi (automatic selection) is not supported, a LAN  
cable (crossover type), switch, or router is required between the  
scanner and remote computer.  
If this is not the case, the LAN cable may be faulty. Find a LAN cable  
that functions normally and try again.  
2
3
IP address or subnet mask is invalid.  
On the "IP Address" screen, check that the IP address or subnet mask  
settings are correct.  
For more details about the "IP Address" screen, refer to "3.5 Setting  
When using DHCP, the DHCP server does not Check the DHCP server connection status and the details of the server  
settings.  
operate normally, or there is a problem with  
the DHCP server settings.  
If using DHCP, on the "Network Status" screen, check that IP  
address, subnet mask, and default gateway settings are all correct.  
If these settings are not correct, the DHCP server may not operate  
normally, or the DHCP server may not assign valid IP addresses  
because of restricted number of leases or MAC address validation.  
If the DHCP server operating environment is changed, restart the  
scanner.  
The "Network Status" screen can be displayed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [Down] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
4
Another host or communication device is  
connected using the same IP address as the  
scanner.  
If the same IP address has already been used by another host or  
communication device, then even if the other device has been given a  
different IP address the remote computer may not recognize the  
scanner’s "duplicate" IP address until it is rebooted. Restart the  
remote computer.  
If a duplicate IP address connection from another host or  
communication device exists on a LAN, both it will be unusable.  
If a duplicate IP address connection from another host or  
communication device exists, pull out its LAN cable and restart the  
remote computer.  
5
Access is denied due to the establishment of a If a firewall has been established between the remote computer and  
firewall between the remote computer and the the scanner, check that it has not been set to deny access to the  
scanner.  
network.  
Network Scanner fi-6000NS Getting Started  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
No.  
Problem  
Action  
6
The network link speed/duplex mode for the  
scanner and remote computer are invalid, or  
Auto-Negotiation is not supported by the  
remote computer.  
For this scanner, the default [Link Speed/Duplex Mode] setting is  
"Auto-Negotiation".  
On the "Network Status" screen, match the scanner and remote  
computer's network link speed/duplex mode settings.  
If the problem persists in spite of having set both the scanner and  
remote computer's network link speed/duplex settings to "Auto-  
Negotiation", change "Auto-Negotiation" to a fixed mode and check  
again.  
On the "Network Status" screen, change [Link speed / Duplex mode]  
from "Auto-Negotiation" to a fixed mode.  
This can be changed as follows:  
1. Select the [Network Settings] tab on the top menu.  
2. Press the [Down] button on the left side menu.  
3. Select the [Network Status] tab on the left side menu.  
4. On the "Network Status" screen, select [Link Speed/Duplex  
Mode].  
5. Press the [OK] button.  
Failure to Connect to a Remote Computer using its Server Name  
If connection to a remote computer using a FQDN is not possible even after the server name has been checked using a  
ping test, try the following steps:  
No.  
Problem  
Action  
1
Check if a network connection is possible by trying the same solution  
2
3
The scanner's DNS server or WINS server  
settings are invalid.  
Check that the DNS and WINS server settings are correct.  
The DNS server or WINS server is not  
Ping the DNS and WINS servers to check they are functioning  
functioning normally, or there is an error with normally.  
the DNS or WINS server network connection. If the DNS or WINS server is not functioning, request the network  
administrator to check its status.  
Failure to Connect to the Scanner using a Web Browser  
If the login screen does not appear after the scanner's URL is specified in the web browser, try the following steps:  
No.  
Problem  
Action  
1
Check if a network connection is possible by trying the same solution  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
No.  
Problem  
Action  
2
The DNS server or WINS server is not  
For the URL in the web browser, use the following IP address to  
functioning normally, or the scanner name has check the connection.  
not been registered in the DHCP or WINS  
server.  
If it is possible to connect the scanner from the web with a specified  
IP address, specify the scanner's IP address in the DNS or WINS  
server. Also, check the DNS or WINS server settings on the web  
browser terminal.  
3
4
A misconfigured firewall between the web  
browser and the scanner is denying access.  
If there is a firewall between the computer running the web browser  
and the scanner, check that it settings are not preventing access.  
In Microsoft® Internet Explorer, in the  
"Tools" menu, "Internet Options", [Security]  
tab, the security level for the corresponding  
zone is set as "high", or in [Custom Level],  
"Scripting", "Active Scripting" is set to  
"Prompt" or "Disable".  
If the URL includes a scanner name, the scanner will be connected  
using an Intranet Zone. If the URL includes an IP address, the  
scanner will be connected using the Internet Zone.  
In Microsoft® Internet Explorer, in the "Tools" menu, "Internet  
Options", try the following settings for the corresponding zone.  
To enable "Active Scripting", set in one of the following ways:  
In the [Security] tab, set the required "Security level for this  
zone" to "Medium".  
In the [Security] tab, click the [Custom Level] button. Then,  
set the "Scripting", "Active Scripting" to "Enable".  
If connecting via the Internet zone, on the [Privacy] tab, set the  
level to below "Medium High".  
After the above settings have been performed, in "Temporary  
Internet Files", press the [Delete Cookies] button to delete all  
temporary internet files.  
Problems when Connecting to the Scanner using a Web Browser  
If, when connecting to the scanner via a web browser the "Scripts are usually safe. Do you want to allow scripts to run?"  
message appears, or if, when connecting to the scanner via a web browser, the "Login" screen appears but the buttons  
can not be selected, try the following steps:  
No.  
Problem  
Action  
1
In Microsoft® Internet Explorer, in the "Tools"  
menu, "Internet Options", [Security] tab, the  
security level for the corresponding zone is set as  
"high", or in [Custom Level], "Scripting", "Active  
Scripting" is set to "Prompt" or "Disable".  
If the URL includes a scanner name, the scanner will be  
connected using an Intranet Zone. If the URL includes an IP  
address, the scanner will be connected using the Internet Zone.  
In Microsoft® Internet Explorer, in the "Tools" menu, "Internet  
Options", try the following settings for the corresponding zone.  
To enable "Active Scripting", set in one of the following  
ways:  
In the [Security] tab, set the required "Security level for  
this zone" to "Medium".  
In the [Security] tab, click the [Custom Level] button.  
Then, set the "Scripting", "Active Scripting" to "Enable".  
If connecting via the Internet zone, on the [Privacy] tab, set  
the level to below "Medium High".  
After the above settings have been performed, in  
"Temporary Internet Files", press the [Delete Cookies]  
button to delete all temporary internet files.  
Network Scanner fi-6000NS Getting Started  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix E Troubleshooting  
Problem  
Check Item  
Suggestion  
Press the Startup button.  
Scanner cannot be  
turned on.  
Has the Startup button been pressed?  
Are the AC cable and AC adapter  
properly connected to the scanner?  
Connect the AC cable and the AC adapter.  
Disconnect the AC cable from the scanner, wait at least  
ten seconds, then reattach the cable and turn the power  
back on again. If the problem persists, contact your  
FUJITSU scanner dealer or an authorized FUJITSU  
scanner service provider.  
Scanning does not  
start.  
Has the document been loaded correctly  
into the ADF paper chute?  
Reload the documents into the ADF paper chute.  
Is the ADF completely closed?  
Close the top cover completely.  
Does the same problem occur after  
turning the scanner power off and back  
on again, and re-logging in?  
If the error status persists, contact your FUJITSU  
scanner dealer or an authorized FUJITSU scanner  
service provider.  
Multifeed errors  
occur frequently.  
Do the documents satisfy the required  
quality conditions?  
Use documents which satisfy the quality conditions.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Has the document been loaded correctly  
into the ADF paper chute?  
Riffle and realign the document stack, then load it back  
into the ADF paper chute.  
Is the document stack more than 5 mm  
thick?  
Remove sheets from the stack to reduce it to a thickness  
of 5mm or less.  
Is the pad assembly dirty?  
Clean the pad assembly.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Is the pad assembly worn out?  
Replace the pad assembly.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Paper is not fed into  
the scanner.  
(Pick errors are  
Do the documents satisfy the required  
quality conditions?  
Use documents which satisfy the quality conditions.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
frequent or document  
feed stops midway)  
Is the pick roller dirty?  
Clean the pick roller.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Is the pick roller worn out?  
Replace the pick roller.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Is there any foreign matter in the  
document feed path?  
Clean the document feed path.  
Scanned data is  
elongated.  
Are the feed rollers dirty?  
Clean the feed rollers.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Shadow on the  
leading edge of the  
scanned data.  
Are the feed rollers dirty?  
Clean the feed rollers.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Vertical line on the  
scanned data.  
Are the glass scanner windows dirty?  
Clean the glass scanner windows.  
For more details, refer to "Network Scanner fi-6000NS  
Operator's Guide".  
Scanned data appears Has the document been loaded correctly? Load the document correctly.  
skewed or distorted.  
Quality of scanned  
data is poor.  
Are the glass scanner windows dirty?  
Clean the glass scanner windows.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network Scanner fi-6000NS  
Getting Started  
P3PC-1862-01EN  
Date of issuance: May 2007  
Issuance responsibility: PFU LIMITED  
z Copying of the contents of this manual in whole or in part and  
copying of the scanner application is forbidden under the copyright  
law.  
z The contents of this manual are subject to change without notice.  
z PFU LIMITED. is not liable whatsoever for any damages resulting  
from use of this scanner and procedures described in this manual,  
profit due to defects, and any claims by a third party.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Elation Professional Work Light 12 Brick User Manual
Estate Clothes Dryer EED4400W User Manual
Extron electronic Car Satellite TV System 330 D User Manual
Fisher Paykel Oven OB60SL7 User Manual
Frigidaire Oven FGEW2745K User Manual
Frigidaire Refrigerator Artic Air Commerical Glass Door Refrigerator User Manual
Fujitsu Server V610 User Manual
Garmin All in One Printer PRO 4900 User Manual
GE Double Oven JMP28 User Manual
Gitzo Camcorder Accessories GT1550T User Manual