UV-AIRE™ AIR PURIFYING SYSTEM
Model: UV-12,18
ITEMS INCLUDED IN KIT:
1-UV-Aire™ power unit
4-Sheet metal mounting screws
1-Angled mounting bracket
1-Flat mounting bracket
1-Duct board mounting bracket
1-Ultra Violet lamp
1-Instruction Sheet
1-Wing nut
Caution Labels
Gasket
UV-C light inhibits the growth and reproduction of germs and bacteria that circulate through a
homes’ heating and air conditioning system. The treatment is a safe, silent, and proven way
to make your home a healthier place to live.
READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION
LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE
AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
DO NOT INSTALL THIS UNIT IF ANY DAMAGE IS NOTICEABLE.
SAFETY CONSIDERATIONS
WARNING: Never expose eyes or skin to UVC light from any source.
• Looking directly at the UVC light may cause permanent eye damage or blindness.
• Never operate the UV-Aire™ Air Purifying System out of the plenum.
• Designed for a closed duct system. Do not mount near a supply or a return air opening
• All duct openings in direct line of site of the UV light must be sealed with aluminum duct tape or equivalent
sealing methods.
WARNING: UV light will break down plastic materials not rated for UV exposure:
(Examples: wire insulation, flex duct, drain pans and humidifiers)
• The unit must be mounted at least 30” from the above stated type of materials.
• If it is necessary to mount the unit in direct line of site of these types of materials, they must be shielded
with aluminum foil, aluminum foil tape, or sheet metal.
WARNING: DO NOT mount this unit outdoors.
• This product is designed for indoor installation only (i.e. attics, crawl spaces, basements, etc.).
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Determine the type of duct you have.
(For flex duct applications, refer to Figure 21 on page 8)
IF YOU HAVE METAL DUCT:
a. Apply supplied wet and stick mounting template to air duct in
either a vertical or horizontal position as shown in Figure 2.
b. Drill 1/8” diameter mounting holes at positions indicated on
template.
c. Cut out the marked openings on template using a hole saw
or a pair of tin snips or jigsaw. (See Figure 2)
d. Remove paper template from duct.
IF YOU HAVE DUCT BOARD:
a. Mount the supplied metal mounting plate onto the duct with
duct tape in either a vertical or horizontal position as shown
in Figure 2. (See Figure 3)
Figure 2
b. Bend tabs outward as shown in figure 4.
c. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See
Figure 5)
d. Remove the cut piece of duct. (See Figure 6)
e. Bend both tabs down and through duct at first bend point. (See Figures 7 & 8)
f. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material.
(See Figures 9 & 10
g. Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See
Figure 11)
Figure 3
Figure 4
Figure 5
Figure 6
Figure 8
Figure 9
Figure 10
Figure 11
Figure 7
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.
Page 3
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Remove base unit and cover from box.
4. Apply supplied “Duct Seal Kit” according to instructions included in kit
(See Figure 12)
Figure 12
5. Determine whether to use flat or angled bracket. (Refer to UV-Aire
“Bulb Mounting Bracket Selection” in section IV for aid in this decision)
a. Flat Bracket Installation
i.
Remove the two hex nuts and flat bracket from included bagged
hardware.
ii.
Install the flat bracket and secure to the unit base with the hex
nuts provided. (See Figure 13)
Figure 13
b. Angled Bracket Installation
NOTE: For angled bracket mounting, refer to specifications outlined by
Diagrams A & B for mounting distances in the “Angled Lamp Mounting
Bracket Specifications” in section IV.
i.
Remove the two hex nuts and angled bracket from included
bagged hardware.
ii.
Install the angled bracket and secure to the unit base with the hex
nuts provided. (See Figure 14)
NOTE: Be sure to note location of lamp hole in bracket relative to
unit base.
Figure 14
6. Mount the unit base to the duct using the four mounting screws provided. (See Figure
15)
7. Remove tag and alcohol wipe from lamp. Wipe off lamp being sure not to touch lamp
with bare hands. The oils from your hands will reduce lamp output.
Figure 15
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
8. Insert lamp through hole until lamp cannot be inserted any further. (See
Figure 16)
Figure 16
9. Swing the swivel bracket over end of lamp. Hand-tighten the wing nut
on stud. (See Figure 17) Be careful not to over tighten the wing nut. The
porcelain at the lamp base may crack when over tightened.
Figure 17
10. Plug ballast plug into end of lamp. (See Figure 18)
11. Snap cover onto the unit base. Close the cover and tighten cover screw. (See
Figure 19 & 20)
Figure 18
12. Plug the power cord into a standard electrical outlet.
Figure 19
NOTE: Seal the joints and seams of the plenum near the mounting
location to reduce any direct viewing of light. (See Figure 1)
Figure 20
13. Press the power switch to the ‘ON’ position. (Light on switch should be on indicating power.)
14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port
is covered with a plastic lens that blocks the UVC rays.)
15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252-
522-3031 for further assistance.
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
IV.
BULB MOUNTING BRACKET SELECTION
The UV-AIRETM units come with an angled mounting bracket and flat mounting bracket to position the bulb either
straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the
configurations chart below when making your selection.
UV-Aire™ Configurations
Good
Best
Standard 90°
Installation
Patent Pending 45°
Installation
(Flat Bracket)
(16” Duct)
Single Lamp
(Angled Bracket)
(16” Duct)
ANGLED LAMP MOUNTING BRACKET SPECIFICATIONS
Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.
Chart A
Chart B
LAMP OFFSET DIMENSIONS
Min Duct
Unit
Size
(inches)
9x12
A
B
UV-12
UV-18
8-1/2
13-1/2
6-1/2
10-5/16
14x18
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
V.
MAINTENANCE
1. Inspect and clean lamp at least every 6 months.
2. Replace your UV-Aire™ Air Purifying System lamp once a year to maintain the lamps maximum output intensity.
The lamp should operate continuously for maximum lamp life and light effectiveness.
VI.
LAMP REPLACEMENT PROCEDURE
VERY IMPORTANT: Turn switch on unit to ‘OFF’ position and unplug unit from outlet.
1. Loosen the cover screw on the side of the unit and open cover.
2. Unplug ballast plug from end of lamp.
3. Loosen the wing nut on swivel bracket and rotate the bracket clockwise.
4. Slide lamp out carefully.
NOTE: When replacing the lamp, always wipe off lamp before installing.
5. Insert the lamp through the mounting hole and secure the lamp by rotating the swivel bracket counter-clockwise
into position and secure by tightening wing nut. Be careful not to over tighten the wing nut.
NOTE: UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste
management authority for local disposal or recycling requirements. According to the EPA’s Universal Waste Rule,
these types of lamps may be disposed of into household waste.
6. Attach the ballast plug onto the end of the lamp.
7. After replacing lamp, make sure a new Lamp Replacement Label (supplied with lamp replacement) is applied to
the housing and dated with the date of installation.
VII.
TROUBLESHOOTING GUIDE
1. If the lamp does not light up, replace the lamp.
2. If the lamp still does not light up after replacing the lamp, replace ballast.
REPLACEMENT PARTS LIST
VIII.
LAMP
BALLAST
(Field Controls Part Number)
MODEL
(Field Controls Part Number)
UV-12
46365401
46365402
46365508
46365509
UV-18
For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your
hands.
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
IX.
FLEX DUCT INSTALLATION
For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 21
below.
Figure 21
Limited Warranty
Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall
be free from defects in material and workmanship under normal use for eighteen (18) months from date
of manufacturing by the consumer excepting the provisions numbered below.
UV-LAMPS/BULBS
Field Controls, L.L.C. warrants that the following Field Controls, L.L.C. products sold hereunder, shall
be free from defects in material and workmanship under normal use for ninety (90) days from date of
installation by the consumer excepting the provisions numbered below.
Provisions:
1. Field Controls shall have no obligation in the event the customer is unable to provide receipt
showing the date the customer purchased the product(s) or accurate date code information.
2. The product must be properly installed, maintained and operated under normal conditions.
3. Field Controls shall not be liable for any consequential and incidental damages, resulting from
failure of a Field Controls, L.L.C. product, failure to deliver, delay in delivery, delivery in
nonconforming condition, or for any breech of contract or duty between Field Controls, L.L.C.
and the customer.
4. Field Controls, L.L.C. products are often intended for use in specific applications. Field
Controls, L.L.C. makes no warranty if a Field Controls, L.L.C. product is used in applications
other than intended.
5. Field Controls, L.L.C. makes no warranty of any kind in regard to any other manufacturer’s
products distributed by Field Controls, L.L.C. Field Controls, L.L.C. will pass on all warranties
made by the manufacturer and where possible, will expedite the claim on behalf of the
customer, but ultimately, responsibility for disposition of the warranty claim lies with the
manufacturer.
The health aspects associated with the use of these products and their ability to aid in disinfecting of environmental air have not been investigated by UL.
P/N 46360900 Rev N 09/04