Extron electronic Switch SW4 3G HD SDI User Manual

SW4 3G HD-SDI Setup Guide  
RATE  
NOT  
AUTO  
RECOGNIZED  
SWITCH  
1
2
3
4
2.97 Gbps  
1.485 Gbps  
270 Mbps  
ACTIVE  
MODE  
NORMAL  
AUTO  
SW4 3G HD-SDI  
MULTI-RATE SDI SWITCHER  
INPUTS  
OUTPUTS  
1
2
3
4
1
2
RS-232  
Tx Rx  
100-240V~.5A MAX.  
50/60 Hz  
The Extron® SW4 3G HD-SDI switcher is a four input, two parallel output, multi-rate switcher. It allows up to four SDI or  
HD-SDI video input sources to be switched to two identical outputs, on female BNC connectors. The SW4 HD-SDI supports  
multiple SDI rates, including 270 Mbps, 1.485 Gbps, and 2.97 Gbps. In auto-input switch mode, the SW4 3G automatically  
switches to the highest numbered input with active sync pulses.  
This guide provides basic instructions for an experienced installer to set up and operate this switcher.  
Installation  
1. Turn off all of the equipment and disconnect it from the power source.  
2. (Optional) If desired, mount the switcher on a 6 inch or 9.5 inch deep rack shelf.  
3. Connect up to four SDI, HD-SDI, or 3G-SDI video inputs to BNC input connectors 1 through 4.  
Switcher  
Computer  
NOTE: Each input is equalized regardless of the rate.  
RS-232  
5
1
Tx Rx  
4. Connect one or two video SDI, HD-SDI, or 3G-SDI output devices to the  
rear panel BNC output connectors.  
9
6
DB9 connector (female)  
pinout to control equipment  
NOTE: Outputs 1 and 2 output identical signals.  
Pin  
1
2
3
4
5
6
7
8
RS-232  
Rx  
Tx  
Gnd  
Function  
Receive data (+)  
Transmit data (–)  
5. If the switcher will be connected to a computer or host controller for  
remote control, wire the provided 3-pole captive screw connector to an  
RS-232 cable. Connect the RS-232 cable to the RS-232 port on the rear  
panel of the switcher and to the host RS-232 port (see the illustration at  
right).  
Signal ground  
Protocol for the RS-232 port: 9600 baud, 8 data bits, 1 stop bit, no parity  
6. Power on the input and output devices, then connect power to the  
switcher by connecting the provided IEC power cord to the switcher  
power connector and to an AC outlet.  
9
Figure 1. RS-232 Connection  
Connecting an Input to the Outputs  
To create a tie between an input and the outputs:  
1. Determine the necessary switch mode for the SW4 3G (the default mode is normal). (See “Enabling and Disabling  
Auto-input Switch Mode,” on the reverse side.)  
о
о
Select auto-input switch mode to automatically switch to the highest numbered input with active sync pulses.  
Choose normal mode to manually change the input.  
2. Select an input.  
о
If you are using normal mode, select the desired input by pressing and releasing its input button. The LED beside  
the selected input button lights.  
о
о
To switch to another input, press a different input button.  
If you are using auto-input switch mode, no action is necessary. The switcher automatically switches to the highest  
numbered active input.  
3. If needed, create a remote connection via RS-232. (See step 5 under “Installation,” above.)  
SW4 3G HD-SDI • Setup Guide  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Earthquake Sound Speaker S 10 User Manual
Echo Trimmer SRM 211 User Manual
EdgeStar Freezer FP430 FP860 User Manual
Festool Sander PI567696 User Manual
Ford Automobile 2011 Fusion Hybrid User Manual
Frigidaire Washer FWSC235RF User Manual
Fusion Car Amplifier FM 402 User Manual
Gaggenau Cooktop CK 481 6 User Manual
GE Microwave Oven PEM31 User Manual
GE Network Router PB3 POS RP User Manual