Index
Important Safeguards...............2
Service Information ..................4
Assembly..................................5
Use ...........................................7
Dust Cap ..................................7
Motor Filter ...............................8
Battery Disposal .......................8
Customer Order Form ..............9
Warranty ............................11-12
For location of nearest Eureka
Warranty Station or Service
Information, call 1-800-282-2886.
*En Mexico llame al 5670-6169
Download from Www.Somanuals.com. All Manuals Search And Download.
CONSEILS DE SÉCURITÉ
Lors de l’utilisation d’un appareil électrique, quelques précautions élémentaires doivent
être observées, incluant les suivantes:
LISEZ TOUTES LES INSTRUCTIONS AVANT D’UTILISER VOTRE ASPIRATEUR.
AVERTISSEMENT
Pour réduire le risque de feu, de choc électrique ou de blessure:
•
•
N’utilisez pas l’aspirateur à l’extérieur ou sur une surface mouillée.
N’utilisez jamais l’aspirateur ou le chargeur s’ils ont été endommagés. Si l’aspirateur
ne fonctionne pas comme il le faut, s’il a été échappé, s’il a été endommagé, s’il a
été laissé à l’extérieur, s’il a été échappé dans de l’eau, retournez-le à un centre de
service avant de l’utiliser.
•
•
Pour éviter que l’aspirateur surchauffe, ou que l’aspirateur ou les piles soient
endommagés, n’utilisez pas l’aspirateur lorsqu’il est encore dans son support de
recharge.
Ne permettez pas que l’aspirateur soit utilisé comme un jouet. Une attention
particulière est nécessaire lorsqu’il est utilisé par ou près d’un enfant.
Suivez les recommandations d’utilisation de ce manuel.
Pour recharger l’aspirateur, utilisez uniquement le chargeur qui l’accompagne –
Eureka modèle nº 514 pour 120 volt; modèle nº AD0412-SV1 pour 230 volt.
Ne pas tirer l’aspirateur ou le transporter par le cordon. Ne pas utiliser le cordon en
guise de poignée. Ne pas fermer une porte sur le cordon ou tirer le cordon sur des
bordures ou des coins pointus. Tenir le cordon à distance des surfaces chauffantes.
Ne pas utiliser des rallonges ou des prises qui n’ont pas une capacité suffisante
pour transporter le courant.
•
•
•
•
•
Ne pas débrancher en tirant sur le cordon. Pour débrancher, empoignez le chargeur
et non pas le cordon.
•
•
Ne pas manipuler le chargeur ou l’aspirateur avec les mains mouillées.
NE PAS MUTILER OU INCINÉRER LES PILES. LES PILES EXPLOSENT A DES
TEMPÉRATURES EXCESSIVES.
•
Il peut y avoir des fuites des éléments des piles lorsque celles-ci sont soumises à
des conditions d’emploi excessif ou de température excessive. Si le liquide touche la
peau (1) laver tout de suite la peau avec de l’eau et du savon (2) Neutraliser avec un
acide doux, tel que le jus de citron ou le vinaigre. Au cas de contact avec les yeux,
nettoyer à grande eau pour un minimum de 10 minutes. Cherchez des soins médicaux.
NOTE: Le liquide est une solution à 25-35% d’hydroxyde de potassium.
La borne de l’aspirateur doit être maintenue propre et libre de tout autre objet. Il n’y
a aucun risque de choc électrique de la borne elle-même, mais une brûlure est
possible si des objets en métal sont introduits dans la borne.
•
•
•
•
Cet aspirateur crée de la succion. Tenir les parties mobiles et les ouvertures loin des
cheveux, des habits, des doigts et de toute partie du corps.
Ne pas ramasser des objets qui brûlent ou fument comme des cigarettes, des
allumettes ou les cendres chaudes.
Ne pas utiliser sans que le filtre ne soit installé. Lors de réparations ou d’entretien, il
ne faut jamais mettre les doigts, ou autres objets, près du ventilateur dans le cas où
l’aspirateur serait accidentellement mis en marche.
•
•
Portez une attention particulière lorsque vous nettoyez les escaliers.
Ne pas utiliser pour ramasser des liquides inflammables ou combustibles comme de
l’essence. Ne pas utiliser dans les endroits où ces liquides pourraient être présents.
Situez le support pour l’aspirateur à l’intérieur, dans un endroit frais, sec et protégé
pour éviter le choc électrique ou les dommages.
•
•
•
Travaillez toujours dans un endroit bien éclairé.
Débranchez les appareils électriques avant de les nettoyer avec l’aspirateur.
CONSERVEZ CES INSTRUCTIONS
3
Download from Www.Somanuals.com. All Manuals Search And Download.
GENERAL INFORMATION
The cordless vacuum cleaner is the answer for quick, convenient, and easy cleanups.
Grab the cleaner for little tasks rather than using a larger cleaner. Place the wall bracket
in any area of easy access that allows versatile cleaning of kitchen crumbs, window
sills, or steps. Always store the cleaner in the wall bracket to provide a ready charge.
Charge for 10-12 hours before first use.
Batteries could lose charge in shipping.
It is best to charge the batteries when temperatures are between 32ЊF (0ЊC) and 104ЊF
(40ЊC). Other temperatures could damage batteries.
While charging, the charger may become warm to the touch. This is a normal condition
and does not indicate a problem.
Important Battery Disposal Information
Nickel-Cadmium Batteries
Your vacuum cleaner uses nickel-cadmium batteries in a removable
pack. To protect our environment, properly dispose of the battery pack
when the batteries no longer hold a charge. A municipal waste will not
dispose of the battery pack.
Remove the battery pack and take or send it to your nearest Eureka
Warranty Service Station. To learn the address of the nearest factory
service center call 1-800-282-2886.
Ni-Cd
NOTE: Remove the battery pack only when the batteries no longer hold a charge
and you plan to dispose of them.
Service Information
The instructions in this booklet serve as a guide to routine maintenance. If additional
service is required, telephone toll free:
USA: 1-800-282-2886
Mexico: 5670-6169
Canada: 1-800-282-2886
for the nearest Eureka Authorized Warranty Station. If you prefer, you can write to The
Eureka Company, Service Division, 807 North Main Street, Bloomington, IL61701, USA.
In Canada write to The Eureka Company, 866 Langs Drive, Cambridge, Ontario N3H
2N7. Refer to The Eureka Warranty for complete service information.
DO NOT OIL. The motor has lubrication and has a permanent seal.
Rating Plate
The model number is indicated on the rating plate
which is located on the underside of the vacuum
cleaner. For prompt and complete service, always
refer to these numbers:
THE EUREKA COMPANY
Bloomington, Illinois 61701 USA
HOUSEHOLD TYPE
MODEL
Model and Type No.______________________
Serial No. or Date Code___________________
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Identify Parts
Recharge
Light
Dust Cup
Latch
Motor
Filter
On/Off
Switch
Dust
Cup
Socket Charger
Wall Mount Bracket
Screws and
Cavity Wall Anchors
Plug Charger
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Attach Charger Plug to Wall Bracket
CAUTION: Use only charger model 514 for 120 volt;
model AD0412-SV1 for 230 volt.
Your vacuum cleaner has a special bracket designed
to hold the unit, so that it may recharge while mounted
on the wall.
Charger Socket
How to Mount your Vacuum Cleaner
Cleaner hangs in bracket with the nozzle end down.
Mount on a wall where there are no dangerous objects
hidden beneath the wall surface like electrical wires,
pipes, etc.
Docking Ledge
1. Hold bracket against wall to mark location for
screws. Make sure the wall bracket is positioned
vertically, with the charger socket at the top.
2. Use a 1/4 inch drill for drilling holes for the plastic
anchors.
3. Insert the anchors and drive the screws into both
holes, leaving 1/4” of each screw exposed.
4. Place the bracket over the screws and slide the
bracket downward to allow the screws to move
into the slots.
Plug Charger
5. Tighten the screws to secure the bracket.
6. Rest the cleaner on the docking ledge, with the
nozzle pointed down, and push in on the top of
the handle until you hear charger socket click into
place.
7. Plug the charger into an electrical outlet.
NOTE: Charge the cleaner for 10-12 hours before initial use. The batteries of a
new cleaner are on a low charge.
Keeping your Vacuum Cleaner Ready for Use
Return your vacuum cleaner to the wall holder after every use. Firmly position into the
mounting bracket ensuring that the vacuum cleaner fits correctly into the charging socket.
It will then be recharged and ready for operation at all times.
The plug charger can be left in the electrical outlet at all times, even when the unit is in
use. It is impossible to overcharge the batteries. The plug charger will become warm,
however, this is not a cause for concern. The unit is charging when the red light on the
top of the vacuum cleaner is illuminated.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
HOW TO USE
1. Push the power switch forward to turn on.
2. Pull the power switch back to turn off.
ᮣ
ᮣ
On
Off
HOW TO MAINTAIN
The instructions given in this booklet serve as a guide to routine maintenance. Keep the
cleaner operating at top efficiency. Empty the dust cup and clean the filter after each
use.
Dust Cup
Latch
Empty Dust Cup
1. Push down on dust cup latch.
2. Pull dust cup from handle section.
3. Remove motor filter from dust cup.
4. Shake contents into a waste
container.
5. Clean motor filter (refer to motor filter
section, page 8).
6. Replace motor filter in the dust cup.
7. Press dust cup onto handle section
until they snap together.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Clean Motor Filter
ᮤ
ᮤ
Clean the motor filter after each cleaner use.
1. Remove the filter frame from the dust cup.
2. Shake and brush the dust and dirt from filter.
3. If desired, remove filter from filter frame and launder the filter by hand in warm water
(150ЊF, 65ЊC) using a mild detergent.
4. Air dry thoroughly.
5. Replace filter over frame.
Replace a dirty or torn filter. Order additional motor filters from The Eureka
Company, Bloomington, IL 61701.
Order motor filter, part number 60684.
Remove Battery Pack for Disposal
For information 1-800-282-2886
Ni-Cd
NOTE: Remove the battery pack only when the batteries no longer hold
a charge and you plan to dispose of them.
CAUTION: Do not short circuit or dispose of in fire. Dispose of properly.
A municipal waste will not dispose of the battery pack. Use a recycling center if
one is convenient. Otherwise, take or send the battery pack to your nearest Eureka
Warranty Service Station. To learn the address of the nearest factory service center
call 1-800-282-2886.
1. Lay cleaner down on its top.
2. Unscrew the one screw on the bottom, flip unit to the right and unscrew the screw on
the side of the handle.
3. Grasp handle with thumb on battery cover. Using thumb push down and slide battery
cover toward wrist. This will loosen the battery cover so it can be freed from the
cleaner.
4. Remove battery pack and dispose of properly. For more information call
1-800-282-2886.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MhfPaymnt(oNDC.Oders)
UMCLANERS
V
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
RANTY
LMITEDW
THUREKA
11
Download from Www.Somanuals.com. All Manuals Search And Download.
©1999 White Consolidated Industries, Inc.
Printed in U.S.A.
Part No. 59753 (11/01)
Download from Www.Somanuals.com. All Manuals Search And Download.
|