Contents
1. General Information……………………………………………………… 3
a. Introduction…………………………………………………………. 3
b. Unpacking………………………………………………………..…. 3
c. Customer Support…………………………………………….……. 3
d. Warranty Registration……………………………………………… 4
e. Discharge Lamp Warning…………………………………………. 4
2. Safety Instructions……………………………………………………….. 6
3. Features…………………………………………………………………… 8
4. General Guidelines………………………………………………………. 9
5. Lamp Installation…………………………………………………………. 10
a. Lamp installation……………………………………………………. 10
b. Lamp optimization………………………………………………….. 11
6. Mounting and Installation………………………………………………… 12
a. Mounting Positions…………………………………………………. 12
b. Mounting Points…………………………………………………….. 12
c. Securing………………………………………………………………13
7. Understanding DMX……………………………………………………… 15
a. DMX Connections………………………………………………….. 15
b. DMX Terminator……………………………………………………. 15
c. 3-Pin to 5-Pin Conversion…………………………………………. 17
d. DMX Addressing……………………………………………………. 17
8. Fixture Menu………………………………………………………………. 19
a. Menu functions……………………………………………………… 21
9. DMX Channel Traits……………………………………………………… 36
a. DMX Channel Values……………………………………………… 37
10.Error Codes……………………………………………………………….. 39
11.Cleaning and Maintenance………………………………………………. 41
12.Warranty…………………………………………………………………… 42
13.Technical Specifications…………………………………………………. 44
14.Photometric Data………………………………………………………….45
15.Gobo Patterns……………………………………………………………..45
16.Dimensional Drawings………………………………………………….…45
17.Circuit Schematic………...………………………………………………..46
©Elation Professional®
3
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
1. General Information
INTRODUCTION: Congratulations, you have just purchased one of the most innovative
and reliable lighting fixtures on the market today! The Focus Spot 250R™, has been
designed to perform reliably for years when the guidelines in this booklet are followed.
Please read and understand the instructions in this manual carefully and thoroughly before
attempting to operate this unit. These instructions contain important information regarding
safety during use and maintenance.
UNPACKING: Thank you for purchasing the Focus Spot 250R™ by Elation Professional®.
Every Focus Spot 250R™ has been thoroughly tested and has been shipped in perfect
operating condition. Carefully check the shipping carton for damage that may have
occurred during shipping. If the carton appears to be damaged, carefully inspect your unit
for damage and be sure all accessories necessary to operate the unit have arrived intact. In
the event damage has been found or parts are missing, please contact our customer
support team for further instructions. Please do not return this unit to your dealer without
first contacting customer support at the number listed below.
CUSTOMER SUPPORT: Elation Professional® provides a customer support line, to provide
set up help and to answer any question should you encounter problems during your set up
comments or suggestions. For service related issue please contact Elation Professional®.
Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacific Standard Time.
Voice:
Fax:
(323) 582-3322
(323) 582-3108
E-mail:
Forum:
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to
rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs
yourself, doing so will void your manufactures warranty.
Please do not discard the shipping carton in the trash. Please recycle whenever possible.
©Elation Professional®
4
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
WARRANTY REGISTRATION: The Focus Spot 250R™ carries a two year (730 days)
limited warranty. Please fill out the enclosed warranty card to validate your purchase. All
returned service items whether under warranty or not, must be freight pre-paid and
accompany a return authorization (R.A.) number. The R.A. number must be clearly written
on the outside of the return package. A brief description of the problem as well as the R.A.
number must also be written down on a piece of paper and included in the shipping
container. If the unit is under warranty, you must provide a copy of your proof of purchase
invoice. Items returned without a R.A. number clearly marked on the outside of the package
will be refused and returned at customer’s expense. You may obtain a R.A. number by
contacting customer support at (323) 582-3322.
DISCHARGE LAMP WARNING: This fixture is fitted with a discharge
lamp, which is highly susceptible to damage if improperly handled.
Never touch the lamp with your bare hands, as the oil from your hands
will shorten lamp life. Also, never move the fixture until the lamps have
had ample time to cool. Remember, lamps are not covered under
warranty conditions.
This fixture emits intense UV radiation, which is harmful to the eyes and skin. The intense
luminance of the lamp can cause severe damage to the retina. Never operate this fixture
with the protective covers removed, these covers have been specially designed to shield
against UV radiation.
Epileptic Warning: Those suffering from epilepsy should avoid looking directly into the
lamp at all times.
Avoid switching the fixture on and off repeatedly in short intervals, as this will reduce lamp
life and intensity.
To achieve the intensity associated with discharge lamps, these lamps use a gas sealed in
a high-pressure environment to emit a brilliant output. Due to the high pressure involved
with the construction of the lamp, the lamp may explode during prolonged extensive use.
This risk is increased with age; added care is encouraged when dealing with older lamps.
Thus, lamp should always be replaced at the end of their recommended duty cycle.
©Elation Professional®
5
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Extreme caution should be used when operated this or any fixture fitted with a gas
discharge lamp.
Never open this fixture while in use!
During the initial operation of this fixture, a light smoke or smell may emit from the interior of
the fixture. This is a normal process and is caused by excess paint in the interior of the
casing burning off from the heat associated with the lamp and will decrease gradually over
time.
This device falls under protection-class I. Therefore it is essential that the device be
grounded properly.
All electrical connections must carried out by qualified person.
Be sure the available voltage matches the voltage requirements of the unit.
Be sure the power cord is never crimped or damaged. If the power cord is damaged,
replace it immediately with a new one of similar power rating.
Always disconnect from main power before performing any type of service or any cleaning
procedure.
Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion
of the cord.
Please be aware that damages caused by manual modifications to the device are not
subject to warranty.
©Elation Professional®
6
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
2. Safety Instructions
The Focus Spot 250™ is an extremely sophisticated piece of
electronic equipment. To guarantee a smooth operation, it is
important to follow the guidelines in this manual. The
manufacturer of this device will not accept responsibility for
damages resulting from the misuse of this fixture due to the
disregard of the information printed in this manual.
1. Always be sure that the fan and the air inlets remain clean and are never blocked.
Allow about 6” (15cm) between this fixture and other devices or a wall to allow for
proper cooling.
2. Never touch the fixture during normal operation. This can cause severe personal
injuries and/or damage to the fixture.
3. Be sure to unplug the FOCUS SPOT 250R™ from the power outlet before
performing any service related issues.
4. Lamp Replacement; Allow at least 30 minutes after disconnecting main power
before you open the FOCUS SPOT 250R™. To prevent personal injury, never
touch the lamp if you are not absolutely sure it has cooled.
5. Never look directly into the lamp beam. You risk injury to your retina, which may
induce blindness.
6. Be sure to track and record the lamp running time. The lamp should be changed
at the end of the specified lamp life, regardless of lamp output. You may also have
to change the lamp if it shows any deformations or damage. The same is with all
glass components, color filters, lenses and mirrors.
7. For safe operation, follow the Installation guide described in chapter two of this
manual. Operating the FOCUS SPOT 250R™ without suited safety aids such as
safety cables or clamps can increase the risk of damage and/or personal injury.
8. Installation should only be performed by qualified and certified personal.
9. When mounting this fixture, use only the original rigging parts included with this
fixture. Any structural modification will void the original manufactures warranty and
may increase the risk of damage and/or personal injury.
10. To reduce the risk of fire or shock do not expose this fixture to rain or moisture.
©Elation Professional®
7
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
11. Do not attempt to operate this fixture if the power cord has become damaged or
frayed.
Important Notice: Damages resulting from the disregard of safety and general user
instructions found in this user manual are not subject to any warranty claims.
Never touch the device during operation!
The housing may heat up
Never look directly into the light source,
as sensitive persons may suffer an epileptic shock.
©Elation Professional®
8
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
3. Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pan 630° or 540˚ (User selectable) / Tilt 265°
18° Beam Angle
8 Dichroic color plus spot, for a total of 9 colors
7 Rotating Gobos
Strobe: 0~10Hz
Electronic Focus via DMX
Sound Active – Master/Slave Operation
4 Segment Digital LED
High-speed pan & tilt movements
Reversible Display (Can be turned 180°)
Bright MSD 250 Discharge Lamp
Lamp switches ON/OFF locally
Glass Dichroic Reflector for Even Lamp Output
User Selectable Power Supply (Internal)
USITT DMX-512 Complaint
RDMX (Remote DMX addressing from any DMX console)
11 DMX Channels
Long Life Phillips MSD250/2 Lamp (250w, 8500˚k, 3000hrs)
Automatic Pan/Tilt Correction
Anti-reflection Coated Lenses
Internal Program:
Edit and save programs to the incorporated EEPROM through the front control panel or
external controller; you can save a maximum of 48 scenes, and run the saved
programs by using the “run” menu on the front control panel
©Elation Professional®
9
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
4. GENERAL GUIDELINES
This fixture is a professional lighting effect for designed for use on stage, in nightclubs, in
theatres, etc. Do not attempt operation or installation without a proper knowledge on how to
so.
This fixture was designed for indoor use only.
Consistent operational breaks may ensure that the fixture will function properly for may
years to come.
Do not shake the fixture around. Avoid brute force when installing or operating the device.
While choosing an installation location, please be sure that the fixture will not be exposed to
extreme heat, moisture or dust. The minimum distance between the fixture and a wall or flat
surface should be at least .5 meter.
Always install the fixture with an appropriate safety cable. When installing the fixture in a
suspended environment always be to use mounting hardware no less than M10 x 25 mm,
also be sure the hardware is insert in the pre-arranged screw holes in the base of the
fixture.
When using the quick release “Omega” cam-lock system, be sure the four quick lock
fasteners are locked in the quick lock holes correctly.
Do not attempt to operate this fixture until you have familiarized yourself with its functions.
Do not permit operation by persons not qualified for operating this type of theatrical fixture,
most damages are the result of operations by nonprofessionals.
Please use the original packaging to transport the fixture in for service.
©Elation Professional®
10
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
5. LAMP INSTALLATION INSTRUCTIONS
Installing or replacing the lamp
Only install the lamp with the device unplugged from the mains.
The lamp has to be replaced when it is damaged or deformed.
Before replacing the lamp be sure the unit has ample time to cool, to avoid injury to yourself
never touch the lamp when it is hot.
During the installation of halogen lamps do not touch the glass bulbs bare handed. Always
use a cloth to handle the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate higher temperatures than which
the device was designed for.
For the installation, you need one MSD250/2 GY9.5 lamp;
Procedure:
1. Remove the two thumbscrews labeled “A” and “B” on the rear housing of the head.
2. Gently pull the lamp/socket assembly to access the lamp.
3. Gently remove the old lamp by grasping it by the ceramic base.
4. Carefully insert the new lamp into the socket. Please remember there is only one way
to insert the lamp. Once the lamp has be inserted into the socket, gently slide the
socket assembly back into place and fasten the two thumb screws.
©Elation Professional®
11
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Lamp Optimization
The lamp orientation and optimization must be adjusted after every lamp change. This
procedure centers the lamp in the reflector. Proper optimization will increase lamp life and
ensure a bright crisp output. Improper optimization may add a yellow tint to the lamp output
and reduce intensity. The minimum deviation amount is 1.0mm. Running the fixture within a
lower deviation can cause damage to the lamp and/or lens.
The Focus Spot 250R™ lamp holder is aligned at the factory. However, due to slight
imperfections in all lamps, fine adjustments will improve light performance. Please follow
the procedure below for proper lamp optimization:
1. Using either a DMX controller or the control panel on the unit, strike the lamp and
focus the light on a flat surface (beam open, white, no gobo, no effects).
2. Center the hot-spot (the brightest part of the beam) using the 3 adjustment screws.
Turn one screw at a time to drag the hot-spot diagonally across the projected image.
If you cannot detect a hot-spot, adjust the lamp until the light is even.
3. To reduce a hot-spot, pull the lamp in by turning all three screws clockwise 1/4-turn
at a time until the light is evenly distributed.
4. If the light is brighter around the edge than it is in the center, or if light output is low,
the lamp is too far back in the reflector. "Push” the lamp out by turning each the
adjustment screws ("1, 2, 3”) counterclockwise _-turn until the light is bright and
evenly distributed.
Do not operate this device with open cover
Please remember that a MSD-250/2 lamp is not a hot-restrike lamp therefore, you must
wait approximately 15 minutes after having turned the lamp off before you can attempt to
strike the lamp once again.
©Elation Professional®
12
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
6. Mounting and Installation
Mounting
The FOCUS SPOT 250R™ is fully operational in three different mounting positions,
hanging upside-down from a ceiling, side mounted, or set on a flat level surface (see
illustration below). Be sure this fixture is kept at least 0.5m away from any flammable
materials (decoration etc.). Always use and install the supplied safety cable as a safety
measure to prevent accidental damage in the event of a clamp failure (see section “b” on
the next page).
Refer to regulations BGV C1
(formerly VBG 70 ) and DIN
VDE0711-217 for proper installation in Europe
To ensure proper installation, only qualified staff should
attempt installation.
Mounting points
The FOCUS SPOT 250R™ has been designed to hold multiple clamps on the bottom of the
unit in several different orientations. Always use an appropriately rated clamp to mount this
fixture to truss. Refer to the printed instructions on the bottom of the fixture for proper clamp
©Elation Professional®
13
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
installation. Never use the carrying handles for secondary attachment.
a) Cam lock System: This system allows a quick and efficient means to
secure a clamp to the unit. To secure a clamp to the unit, attach a clamp
that is rated to handle the weight of the unit to your cam lock. After a clamp
has been attached to the cam lock, attach the cam lock to the designated
position on the bottom of your unit. Lock the cam lock into position by
turning the wing nuts 90°.
90°
b) Be sure to always use two cam locks mounted to the bottom of unit to
ensure safe truss mounting.
Secure the FOCUS SPOT 250R™
Regardless of the rigging option you choose for your FOCUS SPOT 250R™ always
be sure to secure your fixture with a safety cable. The fixture provides a built-in
rigging point for a safety cable on the underside of the fixture, be sure to use this
point and never secure a safety cable to a carrying handle.
©Elation Professional®
14
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
7. Understanding DMX
Data Cable (DMX Cable) Requirements (For DMX and Master/Slave Operation):
Your fixture and your DMX controller require a standard 3-pin XLR connector for data
input and data output (see figure below). If you are constructing your own cables be
sure to use two conductor shielded digital cable rated at a 120 ohms (this cable can
be purchased at almost all professional sound and lighting stores). Your cables should
be made with a male and female 3-pin XLR connector on either end of the cable.
Be sure to follow the above figure when making your own cables. Do not use the ground
lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug
or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding
the shield could cause a short circuit and erratic behavior.
DMX-512 control connection
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the
other side to the male 3-pin XLR input of the moving head (Please refer to the diagram
below.). You can chain multiple moving heads together through serial linking. The cable
needed should be two conductor, shielded cable with XLR input and output connectors.
Always be sure daisy chain your in and out data connections, never split or “Y” your DMX
connections unless you are using an approved DMX splitter such as the Elation Opto
Branch 4™ or DMX Branch/4™.
©Elation Professional®
15
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
DMX-512 connection with DMX terminator
When longer runs of cable are used, you may need to use a terminator on the last fixture to
avoid erratic behavior. A terminator is a 90-120 ohm 1/4 watt resistor that is connected
between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This fixture is
inserted in the female XLR connector of the last fixture in your daisy chain to terminate the
line. Using a cable terminator (Elation part number Z-DMX/T) will decrease the possibilities
of erratic behavior.
CONTROLLER
5-Pin XLR DMX Connectors. Some manufactures use 5-pin XLR connectors for DATA
transmission in place of 3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX
line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must
be used, these adaptors are readily available at most electric stores. The following chart
details a proper cable conversion.
©Elation Professional®
16
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Fixture DMX address;
All fixtures should be given a DMX starting address when using a DMX signal, so the
correct fixture responds to the correct control signal. This digital starting address is the
channel number from which the fixture starts to “listen” to the digital control information sent
out from the DMX controller. The allocation of this starting DMX address is achieved by
setting the correct DMX address on the digital display located on the base of the device.
You can set the same starting address for all fixtures or a group of fixtures, or make
different address for each fixture individually. Be advised that setting all you fixtures to the
same DMX address will subsequently control all fixtures in the same fashion, in other
words, changing the settings of one channel will affect all the fixtures simultaneously.
If you set each fixture to a different DMX address, each unit will start to “listen” to the
channel number you have set, based on the quantity of control channels (DMX channels) of
each unit. That means changing the settings of one channel will affect only the selected
fixture.
In the case of the Focus Spot 250R™, which is a 11 channel fixture, you should set the
starting address of the first unit to 1, the second unit to 12 (11 + 1), the third to 23 (12 + 11),
and so on.
Note:
After switching on, the Focus Spot 250R™ will automatically detect whether a DMX data
signal is being received or not. If DMX data signal is being received, the display will show
"A.XXX" (XXX representing the actual DMX address). If the fixture is not receiving a DMX
©Elation Professional®
17
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
signal the display will flash "A.XXX" (XXX representing the actual DMX address).
If your fixture is connected to a DMX controller and the display is flashing (not receiving a
DMX signal), please check the following:
- The 3 PIN XLR plug (cable with DMX signal from controller) is not connected or is
not inserted completely into the DMX input jack.
- The DMX controller is switched off or defective.
- The DMX cable or connector is defective.
©Elation Professional®
18
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
8. FIXTURE MENU
On-Board System Menu: The FOCUS SPOT 250R™ comes with an easy to navigate
system menu. This next section will detail the functions of each command in the system
menu.
Control Board: The control panel located on the top of the fixture allows you to access the
main menu and make all necessary adjustments to the Focus Spot 250R™. During normal
operation, tapping the “MODE” key once will access the fixture’s main menu. Once in the
main menu you can navigate through the different functions and access the sub-menus
with the Up and Down buttons. Once you reach a field that requires adjusting, tap the
ENTER button to activate that field and use the UP and Down button to adjust the field.
Tapping the Enter button once more will confirm your setting. Once a setting is saved the
LED will briefly readout PASS to confirm a new setting has been made and locked into
memory. You may exit the main menu at any time without making any adjustments by
tapping the EXIT button.
MODE/ESC Button - To access the main menu locate the MODE/ESC button on the front
of the unit. Press this button to activate the system menu. Tap the UP button until you
reach the function you wish to change. When you reach the function you wish to change
tap the ENTER button once to select that menu function. When a function is selected the
menu will begin to flash, use the UP or DOWN button to change the function. Once your
changes are made tap the ENTER button yet again to lock the change in the system menu.
To exit without making any changes tap the MODE/ESC button.
Default settings shaded.
1
ADDR
A001~A511
Indicate the staring DMX address
A001 also is the setting for slave
Automatically test the function
Runs fixture as “master” or “alone”
for auto
2
3
TEST
PLAY
T-01~T-XX
RUN
MSTR/ALON
AUDI
MSTR/ALON
Runs fixture as “master” or “alone”
for audio
AUTO
ON/OFF
OFF/ RUN / AUDI
Runs fixture when no DMX signal is
present
Manually switches lamp “on” and
“off”
4
LAMP
©Elation Professional®
19
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
5
RESE
ALL
Reset all motors and returns fixture
to home
SCAN
COLR
Reset only motors for pan/tilt
Reset only motors for colors
GOBO
Reset only motors for gobo and
rotation
SHTR
Reset only motors for shutter and/or
dimmer
OTHR
LIFE
Reset other motors
Displays the total fixture running
time
6
TIME
0000~9999
0000~9999
LAMP
CLMP
Displays a lamps running time
Clear lamp running time
7
8
9
RPAN
RTLT
FINE
ON/OFF
ON/OFF
ON/OFF
630/540
M-XX M-70
VALU
Reverses the pan movements
Reverses the tilt movements
Switch between 16 bit/8 bit
Pan degree select
Mic sensitivity
Display the DMX512 value of each
channel
10 DEGR
11 MIC
12 DISP
D–XX D-00 (DXXX)
D ON
FLIP
ON/OFF
ON/OFF
Display turn off after 2mins
This function will reverse the display
180
13 SPEC
LAAU
ON/OFF
ON/OFF
Automatic lamp start with power
RDMX
Change DMX address via external
controller
DLOF
DLAY
SPOT
DFSE
ON/OFF
D–XX D-05
ON/OFF
ON/OFF
Switch lamp via DMX
Lamp on delay time
Lamp optimization
Resets all the fixture functions to
default
FEED
ON/OFF
Pan/tilt feedback (error correction)
on/off
VER
V1.0~V9.9
Software version
14 EDIT
STEP
Set the amount of your
program
S–01 ~S–48
SCXX
C–01
:
0 1 XX(00~FFH)
:
C–30
3 0 XX(00~FFH)
T
XXX(001~999)
ON/OFF
TIME
CEDT
RE.XX
REC.
RUN
Auto Save
Program test
ON/OFF
©Elation Professional®
20
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Main Menu Functions
1. ADDRESS MENU -
AOO1 - A511(Value) - This is where you set the fixtures DMX address.
Setting/Changing the DMX Address
After applying power to the FOCUS SPOT 250R™ the LED will display the fixture’s
current DMX address immediately after the reset sequence. If the fixture is not
receiving a DMX signal the display will flash continuously.
To set or adjust a DMX address, please follow the procedure below:
1. Switch on the FOCUS SPOT 250R™ and wait for the fixture reset process to
finished.
2. Press the Mode/Esc button to access the main menu. Toggle through the menu
by pressing the Up and Down buttons until the display showsA001. Tap the enter
button to make changes to the address, the current three digit address will
immediately begin to flash.
3. While the current three-digit address is flashing, use theUp and Down buttons to
select adjust the address. Lock your new address into the unit’s memory by
pressing the Enter button. After the new address has been successfully stored into
the fixture’s memory the LED will briefly readout PASS.
The DMX address is non-destructible and will remain in the fixture’s memory even when
power to the fixture has been switched off. Memory is backed-up and retained by an
internal power source with a five year shelf life.
2. TEST MENU -
T-01 - T-XX(Test) - Tests the functions of each channel. There are eleven DMX channels,
but only channels 1,2,3,4, and 6 can be tested.
TEST MAIN MENU
TEST - This will test the functions of each channel.
1. Access the main menu.
2. Tap the UP button until “TEST”is displayed, press ENTER.
3. The display will show T-01. You can now press the up button and test the different
©Elation Professional®
21
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
channels. For example: If you press the up button until “T-03” is displayed, the
unit will test the color channel, changing the color one by one and show the rainbow
effect with different speeds. There are 11 channels, but only channels 1, 3, 5, 6, 8,
and 9 can be tested.
4. Press MODE/ENTER or EXIT to exit.
3. PLAY MENU -
RUN – This feature is used to run the internal preset programs as either a Master or Slave
(ALON) unit.
AUDI- This feature is used to run the internal preset programs in AUDIO mode as either a
Master or Slave (ALON) unit.
AUTO– Runs the unit without any DMX signal.
PLAY MAIN MENU
RUNbeings automatic playback of the internal scenes -
1. Access the main menu.
2. Tap the UP button until“PLAY”is displayed, press ENTER.
3. Tap the UP button until“RUN”is displayed, press ENTER.
4. Tap the UP button to select either “Master” or “Alone” and press ENTER.
5. Press Mode/Esc to return to the main menu.
AUDIbeings automatic playback of the internal scenes to sound -
1. Access the main menu.
2. Tap the UP button until“PLAY”is displayed, press ENTER.
3. Tap the UP button until“AUDI”is displayed, press ENTER.
4. Tap the UP button to select either “Master” or “Alone” and press ENTER.
5. Press Mode/Esc to return to the main menu.
AUTO beings automatic playback of the internal scenes without the use of a DMX
controller -
1. Access the main menu.
2. Tap the UP button until“PLAY”is displayed, press ENTER.
3. Tap the UP button until“AUTO”is displayed, press ENTER.
4. Tap the UP button to select either “Master” or “Alone” and press ENTER.
©Elation Professional®
22
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
5. Press Mode/Esc to return to the main menu.
4. LAMP MENU -
ON/OFF Manually switches the lamp on and off.
LAMP MENU -
LAMP – This menu function will manually turn the lamp on and off.
1. Access the main menu.
2. Tap the UP button until“LAMP”is displayed, press ENTER.
3. The display will show“ON/OFF”.
4. Press the UP button to select “ON”to activate this function, or “OFF”to
deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
5. RESE (RESET) MENU -
ALL - Resets all the motors in the unit.
SCAN- Resets the Pan and Tilt motors.
COLR(Color) - Resets the color motors.
GOBO- Resets the gobo motors.
SHTR- Resets the shutter motors.
OTHR- Reset all other motors
RESE MAIN MENU
ALL - When you activate this reset function, the fixture will begin to reset all motors.
1. Access the main menu.
2. Tap the UP button until “RESE”is displayed, press ENTER.
3. Tap the UP button until “ALL”is displayed, press ENTER.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset
the color motor.
5. Press ENTER to confirm
6. Press MODE/ESC to return to the main menu.
SCAN - When you activate this reset function, the fixture will only reset the Pan and Tilt
©Elation Professional®
23
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
mirror motor.
1. Access the main menu.
2. Tap the UP button until “RESE”is displayed, press ENTER.
3. Tap the UP button until “SCAN”is displayed, press ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset
the color motor. Press ENTER.
5. Press MODE/ESC to return to the main menu.
COLR - When you activate this reset function, the fixture will only reset the color wheel
motor.
1. Access the main menu.
2. Tap the UP button until “RESE”is displayed, press MODE/ENTER.
3. Tap the UP button until “COLR”is displayed, press MODE/ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset
the color motor. Press MODE/ENTER
5. Press MODE/ESC to return to the main menu.
SHTR - When you activate this reset function, the fixture will only reset the
shutter/dimmer motor.
1. Access the main menu.
2. Tap the UP button until “RESE” is displayed, press ENTER.
3. Tap the UP button until “SHTR” is displayed, press ENTER to confirm.
4. The display will show “ON/OFF.” Press the UP button to select “ON” to restart
the shutter/dimmer motor. Press ENTER to confirm.
5. Press MODE/ESC to return to the main menu.
OTHR - When you activate this reset function, the fixture will only reset any motor not
specified in the other reset commands previously listed.
1. Access the main menu.
2. Tap the UP button until “RESE”is displayed, press ENTER.
3. Tap the UP button until “OTHR”is displayed, press ENTER to confirm.
4. The display will show “ON/OFF”. Press the UP button to select “ON” to reset
the color motor. Press ENTER.
5. Press MODE/ESC to return to the main menu.
©Elation Professional®
24
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
6. TIME MENU -
LIFE- Displays the fixtures total running time.
LAMP- Displays the lamp running time.
CLMP- Clears the lamp running time.
TIME MAIN MENU
LIFE - With this function you can display the total running time of the unit.
1. Access the main menu.
2. Tap the UP button until“TIME”is displayed, press ENTER.
3. Tap the UP button until“LIFE”is displayed, press ENTER.
4. Press MODE/ESC to return to the main menu.
LAMP - With this function you can display the running time of the lamp.
1. Access the main menu.
2. Tap the UP button until“TIME”is displayed, press ENTER.
3. Tap the UP button until“LAMP”is displayed, press ENTER.
4. Press MODE/ESC to return to the main menu.
CLMP - With this function you can clear the running time of
the lamp. Note
Very Important: Please clear the lamp time every time you replace the lamp.
1. Access the main menu.
2. Tap the UP button until “TIME”is displayed, press ENTER.
3. Tap the UP button until “CLMP”is displayed, press ENTER.
4. Press MODE/ ENTER, the display will show “ON/OFF”.
5. Press the UP button to select “ON”to activate this function, or “OFF”to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
7. RPAN MENU -
©Elation Professional®
25
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
This menu setting reverses the Pan movements.
RPAN MENU -
RPAN – This menu function will reverse the mirror PAN movements.
1. Access the main menu.
2. Tap the UP button until“RPAN”is displayed, press ENTER.
3. The display will show“ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
8. RTLT MENU -
This menu setting reverses the Tilt movements.
RTLT MENU -
RTLT – This menu function will reverse the mirror TILT movements.
1. Access the main menu.
2. Tap the UP button until“RTLT”is displayed, press ENTER.
3. The display will show“ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
9. FINE MENU -
This menu item switches between 16 bit (fine) and 8 bit (coarse) modes. When this function
is turned on the fixture will operate in 16 bit (fine) mode. When functioning in 16 bit mode
the fixture will use 11 DMX channels, when the 16bit function is turned off the fixture will
use nine DMX channels.
FINE MENU -
FINE – This menu function will toggle between the 16bit and 8bit operating modes. In
©Elation Professional®
26
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
16bit mode the unit will have 11 DMX channels that includes two pan movement
channels and two tilt movement channels. In 8bit mode the fixture will only have one
pan and one tilt movement channel for a total of nine DMX channels.
1. Access the main menu.
2. Tap the UP button until“FINE”is displayed, press ENTER.
3. The display will show“ON/OFF”.
4. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
10. DEGR MENU -
This menu switches the “PAN” functions between 630˚ (default) and 540˚. When this
function is turned on, the fixture will operate with a pan movement of 630˚.
DEGR – This menu function will toggle between the 630°and 540°for pan movement.
1. Access the main menu.
2. Tap the UP button until“DEGR”is displayed, press ENTER.
3. The display will show“630/540”.
4. Press the UP button to select 630˚ or 540˚ for the pan movement angle
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
11. MIC MENU – This function allows for electronic control of the internal microphone’s
sound sensitivity.
MIC MENU -
1. Access the main menu.
2. Tap the UP button until “MIC” is displayed and press ENTER.
3. The display will show “M-XX” (Where XX represents a value between 00 & 99).
4. Use the UP and DOWN button to adjust the mic sensitivity, 99 being the highest.
5. Press ENTER to confirm and lock your new setting in place.
6. Press MODE/ESC to return to the main menu.
©Elation Professional®
27
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
12. DISPLAY MENU -
VALU(DMX-512 Value) - Display the DMX-512 value of each channel.
D ON(Display On) – Turns the digital display on or off.
FLIP- “Flips” the digital display 180 degrees.
DISP MENU -
This menu function will control the various on-board display features.
VALU – This function will display the DMX value of each channel as it is adjusted
through the use of a DMX console.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show“VALU”.
4. Press ENTER, once again “d-00” will be displayed.
5. Press ENTER to confirm.
6. Press MODE/ESC to return to the main menu.
D ON – This function will turn the display off after the unit has gone two
seconds without
any activity.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show“VALU”.
4. Tap the UP button until “”D-ON” is displayed and tap the ENTER button.
5. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
FLIP – This function will reverse the display readout buy 180˚.
1. Access the main menu.
2. Tap the UP button until “DISP” is displayed.
3. Press ENTER, the display will show“VALU”.
4. Tap the UP button until ”FLIP” is displayed and tap the ENTER button.
©Elation Professional®
28
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
5. Press the UP button to select “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
13. SPEC MENU –
LAAU - Automatic lamp start with power.
EBOC- Allows DMX address to be changed via and external DMX controller.
DLOF - Switch lamp via DMX controller.
DLAY - Lamp delay on time.
SPOT- This provides a spot beam for better lamp optimization.
DFSE(Default) - Resets the unit to default.
FEED – This function turn the DMX correction feature “ON” (default) or “OFF.”
VER (Version) - Displays the software version.
SPEC MAIN MENU -
LAAU – This function control the automatic lamp start feature. By default the unit will
automatically ignite the lamp when unit is turned on. Use this function to turn this
feature on and off.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “LAAU” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
RDMX – This function allows the DMX address to remotely be adjusted from a DMX
console.
Fixture Settings:
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
©Elation Professional®
29
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
3. Tap the UP button until “RDMX” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
Controller Settings:
1. Set the DMX value of channel 1 to a value of 7.
2. Set the DMX value of channel 2 to a value of 7 or 8. When channel 2 is set to "7"
you can adjust the starting address between 1 and 255. When set to "8" you can
adjust the starting address between 256 and 511.
3. Use channel 3 to set your desired DMX starting address. For example: If you
want to set the starting address to 57, set channel 1 to a value of “7,” set channel
2 to a value of “7” and use channel 3 to set your address to 57 by selecting a
channel value of 57. Example 2: If you want to set the starting address to 420,
set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164"
(256+164=420).
4. Wait for approximately 20 seconds for the unit to complete the address
reset function.
DLOF – This feature allow you to control the lamp via DMX.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DLOF” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
DLAY – This function allow the user to set a lamp “strike” delay time.
1. Access the main menu.
©Elation Professional®
30
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DLAY” is displayed, press ENTER.
4. The display will show “D-XX.”
5. Press the UP and DOWN buttons to adjust the delay time.
6. When completed press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
SPOT – This function allows you to optimize the lamp without the use of an external
DMX controller. In this mode, the device will not react to any control signal.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DFSE” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
DFSE - With this function you can restore the factory settings of the device. All
settings will be set back to the default values. Any edited scenes will be lost. When
restoring the factory settings the unit must be set to the address that the unit was in
when you started editing. When you confirm this function, the fixture will begin to
reload the original factory settings.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “DFSE” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
FEED - Use this function to activate the pan/tilt error correction.
1. Access the main menu.
©Elation Professional®
31
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “FEED” is displayed, press ENTER.
4. The display will show “ON/OFF.”
5. Press the UP button to display “ON” to activate this function, or “OFF” to
deactivate this function.
6. Press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
VER - Use this function to display the Software version of the unit.
1. Access the main menu.
2. Tap the UP button until “SPEC” is displayed, press ENTER.
3. Tap the UP button until “VER” is displayed, press ENTER.
4. The display will show “V-1.0,” the display may also show, “V-2.0,” “V-9.9” etc.
5. Press ENTER or MODE/ESC to exit. EDIT - This menu item allows you to write
a program into the memory (EEPROM) via the control panel or via the external
controller.
13. EDIT MENU - This menu item allows you to write a program into the fixture’s memory
(EEPROM) via the control panel or via an external DMX controller.
STEP(S-01 - S-48) - These are the steps slots that you write your programs into. There
are at total of 48 steps.
STXX(SC01 – SC48) - These are the scenes that are stored in your program. There are a
total of 48 scenes. C-01 - C-11 (Channel 1 - Channel 11) – Represents the total fixture
channels for each scene that can be edited.
TIME(Time) - Running time of the entire program.
CEDT- Edit program using a external controller.
REC – Auto save function.
RUN – Program test mode.
EDIT MENU -
RUN - With the function “RUN”, you can run your pre-made program. You can set the
©Elation Professional®
32
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
number of steps under Step (S-01- S-48). You can edit the individual scenes under
Edit.
1. Access the main menu.
2. Tap the UP button until “EDIT”is displayed, press ENTER.
3. Tap the UP button until “RUN”is displayed, press ENTER.
4. “AUTO”is displayed. If you press the UP button it will show “SOUN”.
Select which one you want to activate, and press ENTER.
5. Press UP, to select “ALON” or “NAST”. Which mean stand alone, and
master/slave mode.
6. Select a mode, and press ENTER to confirm.
7. Press MODE/ESC to return to the main menu.
STEP - With this function you can program the number of
individual Program.
steps in your
1. Access the main menu.
2. Tap the UP button until “EDIT”is displayed, press ENTER.
3. Tap the UP button until “STEP”is displayed, press ENTER.
4. The display shows “S-01,” this indicates the first step of your program. You can
call up to 48 scenes in “Run.” For example; if “S-05” is displayed, it means that
the scene will “RUN” the first 5 scenes you saved in “Edit.”
5. Press ENTER to save and MODE/ESC to exit.
SC01 - This function allows you to choose the total number of scenes in your
internal program.
1. Access the main menu.
2. Tap the UP button until “EDIT” is displayed, press ENTER.
3. Tap the UP button until “SC01” is displayed.
4. The display indicates “SC01,” this stands for the first scene of your program.
You may recall up to 48 scenes. For example, if you choose “SC05,” and then
select the “Run” function, the first 5 scenes you saved in “Edit” mode will run.
5. Press ENTER to save and MODE/ESC to exit.
Editing procedure 1: Using the control board only.
1. Access the main menu.
©Elation Professional®
33
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
2. Tap the UP button until “EDIT” is displayed and press ENTER.
3. The display will show “SC-01”, this stands for the scene number. For
example, “SC-01” is displayed, it means you will be editing scene 1, press
ENTER. You can change the scene number by tapping the UP button.
4. Press ENTER, the display will show “C-01,” this represents the channel number.
If “C-01” is displayed, you will be editing the fixture’s channel 1 value of the
selected scene, press ENTER. You can change the channel number by tapping
the UP button.
5. The display will show the DMX value for the channel that is being edited. It will
be displayed as “11XX,” it stands for Channel 11 of the editing scene, the DMX
value is “XX.”
6. Adjust the DMX value by tapping the UP button, until you get the expected
effect for this channel.
7. Press ENTER to enter the editing of the other channels of the scene.
8. Repeat steps 5-8, until you finish setting all the DMX values for all the channels
of this scene, each scene can have 15 channels maximum.
9. Once all the channels are completed, the display will begin to flash “TIME,” this
indicates the time needed to run this scene.
10.Press ENTER to edit the time needed, the display shows “T-XX”, “XX”
stands for the time needed to run this scene. For example, “T-02” means
scene 1 needs 6 seconds to run, “T-15” means this scene needs 45
seconds to run. Note: “XX”is always three seconds not one second.
11.Adjust the time needed by tapping the UP button.
12.Press ENTER to save the settings for the scene you are editing, the display will
change to the next scene automatically.
13.Repeat steps 3-12 to edit other scenes, you can edit and save 48 scenes
maximum.
14.Press MODE/ESC to exit and save your edited scene into the fixtures internal
memory. The number of steps can be defined under “EDIT” and the scenes can
be called up under “Run.” To run the scenes see page 30.
Editing procedure 2: Using an external controller.
1. Call up the first scene in your controller now.
2. Select “SC01” by pressing [UP] or [DN].
©Elation Professional®
34
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
3. Press [MODE/ESC], the display shows “SC01”.
4. Press [MODE/ESC], the display shows “C-01”.
5. Select "CEDT" by pressing [UP] or [DN].
6. Press [MODE/ESC], the display shows "OFF".
7. Press [UP], the display shows "ON".
8. Press [MODE/ESC], the display shows "SC02". You successfully downloaded
the first scene.
9. Adjust the Step-time as described above.
10. Call up the second scene in your controller now.
11. Repeat steps 5-11 until all desired scenes are downloaded.
12. Press [EXIT] to exit. The number of steps can be defined under “STEP” and the
scenes can be called up under “RUN”
©Elation Professional®
35
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
9. DMX Channel Traits:
The chart below details the channel layout for 11 DMX channels (default).
In 8bit mode the “Pan Fine” and “Tilt Fine” channels are not used, thus converting the
fixture into a 9 channel DMX fixture.
CHANNEL 1: Pan movement (max. 630°)
CHANNEL 2: 16 bit pan movement (pan fine)
CHANNEL 3: Tilt movement (max. 265°)
CHANNEL 4: 16 bit tilt movement (tilt fine)
CHANNEL 5: Select one of the 9 colors, color cycle or rainbow effect
CHANNEL 6: Select one of the 6 gobo’s + open or gobo cycle+ gobo shake
CHANNEL 7: Select gobo rotation speed and direction + gobo index
CHANNEL 8: Strobe (0-10Hz), dimming and shutter close/open function + random strobe
CHANNEL 9: Electronic focus
CHANNEL 10: Speed pan/tilt movement, blackout selection
CHANNEL 11: Auto program control + lamp on, motor reset, lamp switch off
©Elation Professional®
36
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
DMX channel function and values:
Channel 1 – PAN Coarse
8bit :
Channel 2 – PAN Fine 16bit
Channel 3 – TILT Coarse 8bit
Channel 4 – TILT Fine 16bit
Channel 5 - Color
Wheel :
0-13
14-27
Open (White)
RED
28-41
BLUE
42-55
GREEN
56-69
YELLOW
70-83
MAGENTA
84-97
ORANGE
98-111
112-128
128-187
188-193
194-255
PURPLE
PINK
Clockwise Color Scroll (fast to slow)
No Rotation
Counter-Clockwise Color Scroll (slow to fast)
Channel 6 - Gobo
0-9
Open
10-19
20-29
30-39
40-49
50-59
60-69
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
70-89
90-109
Gobo 1 Shake (slow to fast)
Gobo 2 Shake (slow to fast)
Gobo 3 Shake (slow to fast)
Gobo 4 Shake (slow to fast)
Gobo 5 Shake (slow to fast)
Gobo 6 Shake (slow to fast)
Gobo Wheel Continuous Rotation (slow to fast)
110-129
130-149
150-169
170-189
190-255
Channel 7 - Gobo indexing, Gobo rotation
0-127
Gobo Indexing
128-187
188-193
194-255
Clockwise Gobo Rotation (fast to slow)
No rotation
Counter-Clockwise Gobo Rotation (slow to fast)
©Elation Professional®
37
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Channel 8 - Shutter, Strobe:
0-31
Shutter Closed
32-63
64-95
Dimmer (close to open)
Strobe Effect (slow to fast)
No function (shutter open)
Pulse-effect in sequences
No function (shutter open)
Random strobe effect slow to fast
No function (shutter open)
96-127
128-159
160-191
192-223
224-255
Channel 9 - Focus
0-255
Continuous adjustment from near to far
Channel 10 – Pan/Tilt Motor Speed
0-4
Max speed
5-225
Max to min speed
Blackout by movement
Blackout by all wheel changing
No function
226-235
236-245
246-255
Channel 11 – Special Functions
0-19
20-39
Color change normal – No split colors
Split Color Operation
40-59
Lamp on
60-79
Lamp switch off
80-84
85-87
88-90
91-93
94-96
97-99
100-119
120-139
140-159
160-179
180-199
200-219
220-239
240-255
Total reset – All motors to the home position
Pan and Tilt motors reset only
Color wheel motor reset only
Gobo wheel motor reset only
Shutter and dimmer motors reset only
All other motors reset only (Focus)
Internal program 1
Internal program 2
Internal program 3
Internal program 4
Internal program 5
Internal program 6
Internal program 7
Internal program 8
©Elation Professional®
38
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
10.ERROR CODES:
When power is applied, the unit will automatically enter a “reset/test” mode. This mode
brings all the internal motors to a home position. If there is an internal problem with one or
more of the motors an error code will flash in the display in the form of “XXer” were as XX
will represent a function number. For example, when the display shows “02Er,” it means
there is some type of error with the channel 2 motor. If there are multiple errors during the
start-up process they will all flash in the display. For example: if the fixtures has errors on
channel 1, channel 2, and channel 5 all at the same time, you will see the error message
“01Er”, “02Er,” and ”05Er” flash repeated 5 times.
If an error does occur during the initial start-up procedure the fixture will self-generate a
second reset signal and try to realign all the motors and correct the errors, if the error
persist after a second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the fixture will make the
following determinations: 1) 3 or more errors - The fixture cannot function properly with
three or more errors therefore the fixture will place itself in a stand-by mode until
subsequent repairs can be made. 2) Less than 3 errors - The fixture has less than 3 errors,
therefore most other functions will work properly. The fixture will attempt to operate
normally until the errors can be correct by a technician. The errors in question will remain
flashing in the display as a reminder of internal errors.
01Er – PAN movement error:
The yoke is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the pan-yoke’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
03Er – TILT movement error:
The head is not located in the default tilt position after start-up or after a reset command.
This message will appear after a fixture reset if the tilt magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
©Elation Professional®
39
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
05Er - Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the color wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er - Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset
command.
This message will appear after a fixture reset if the gobo wheel’s magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er - Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo positioning magnetic-indexing
circuit malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
©Elation Professional®
40
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
11. CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1. All screws for installing the devices or parts of the device have to be tightly
connected and must not be corroded.
2. There must not be any deformations on the housing, color lenses, fixations and
installation spots (ceiling, suspension, trussing).
3. Mechanically moved parts must not show any traces of wearing and must not rotate
with unbalances.
4. The electric power supply cables must not show any damage, material fatigue or
sediments.
Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation.
We recommend a frequent cleaning of the device. Please use a moist, lint- free cloth.
Never use alcohol or solvents.
There are no user serviceable parts inside this fixture with the exception of the lamp.
Please refer all other service issues to an authorized Elation service technician.
Should you need any spare parts, please order genuine parts from your local dealer.
©Elation Professional®
41
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
12. 2-YEAR LIMITED WARRANTY
A. Elation Professional® hereby warrants, to the original purchaser, Elation Professional®
products to be free of manufacturing defects in material and workmanship for a period of
two years, (730 days) from the date of purchase. This warranty shall be valid only if the
product is purchased within the United States of America, including possessions and
territories. It is the owner’s responsibility to establish the date and place of purchase by
acceptable evidence, at the time service is sought.
B. For warranty service, send the product only to the Elation Professional® factory. All
shipping charges must be pre-paid. If the requested repairs or service (including parts
replacement) are within the terms of this warranty, Elation Professional® will pay return
shipping charges only to a designated point within the United States. If the entire instrument
is sent, it must be shipped in its original package. No accessories should be shipped with
the product. If any accessories are shipped with the product, Elation Professional® shall
have no liability what so ever for loss of or damage to any such accessories, nor for the
safe return thereof.
C. This warranty is void if the serial number has been altered or removed; if the product is
modified in any manner which Elation Professional® concludes, after inspection, affects the
reliability of the product; if the product has been repaired or serviced by anyone other than
the Elation Professional® factory unless prior written authorization was issued to purchaser
by Elation Professional®; if the product is damaged because not properly maintained as set
forth in the instruction manual.
D. This is not a service contract, and this warranty does not include maintenance, cleaning
or periodic check-up. During the period specified above, Elation Professional® will replace
defective parts at its expense, and will absorb all expenses for warranty service and repair
labor by reason of defects in material or workmanship. The sole responsibility of Elation
Professional® under this warranty shall be limited to the repair of the product, or
replacement thereof, including parts, at the sole discretion of Elation Professional®. All
products covered by this warranty were manufactured after January 1, 1990, and bare
identifying marks to that effect.
©Elation Professional®
42
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
E. Elation Professional® reserves the right to make changes in design and/or
improvements upon its products without any obligation to include these changes in any
products theretofore manufactured.
F. No warranty, whether expressed or implied, is given or made with respect to any
accessory supplied with products described above. Except to the extent prohibited by
applicable law, all implied warranties made by Elation Professional® in connection with this
product, including warranties of merchantability or fitness, are limited in duration to the
warranty period set forth above. And no warranties, whether expressed or implied, including
warranties of merchantability or fitness, shall apply to this product after said period has
expired. The consumer’s and or Dealer’s sole remedy shall be such repair or replacement
as is expressly provided above; and under no circumstances shall Elation Professional® be
liable for any loss or damage, direct or consequential, arising out of the use of, or inability to
use, this product.
G. This warranty is the only written warranty applicable to Elation Professional® Products
and supersedes all prior warranties and written descriptions of warranty terms and
conditions heretofore published.
©Elation Professional®
43
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
13. TECHNICAL SPECIFICATIONS
Power supply (user selectable):
_98VAC,50Hz;_120VAC,50Hz;_208VAC,50Hz;
_220VAC,50Hz;_230VAC,50Hz;_240VAC,50Hz; or
_98VAC, 60Hz;_120VAC,60Hz;_208VAC,60Hz;
_220VAC,60Hz;_230VAC,60Hz;_240VAC,60Hz;
Power consumption: max. 400W:
Lamp: MSD250 GY9.5 socket, Metal Halide (250w, 8500˚K, 3000hrs)
Fuse: GMA 250v/8A
Motors: 7 micro motors
Pan Movement: 630˚ in 3.5 sec. (default) 540˚ (user selectable)
Tilt Movement: 265˚ in 2.0 sec.
Focus: Motor driven focus from near to far
DMX Drive: Standard DMX-512, 3 pole XLR; [+] = Pin 3 [-] = Pin 2 [Ground] = Pin 1.
Colors: 8 Dichroic colors plus white. (Size: 34mm diameter/1mm width)
Gobos: 6 indexable, interchangeable plus open. (Size: 27mm diameter/24mm
viewable/1mm width)
DMX Channels: 11 (16bit ~ default) / 9 (8bit)
Beam angle: 18˚
Packing dimensions: (58 x 42 x 46) cm
Net weight: 16 KGS
Gross weight: 19 KGS
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any
prior written notice.
©Elation Professional®
44
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Photometric Data:
Gobos:
Dimensional Drawings:
©Elation Professional®
45
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
©Elation Professional®
46
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
©Elation Professional®
47
Focus Spot 250R™
Download from Www.Somanuals.com. All Manuals Search And Download.
Focus Spot 250R™
Elation Professional
4295 Charter Street
Los Angeles, CA. 90058
323-582-3322 / 323-582-3108 fax
©Elation Professional®
48
Focus Spot 250R™