Eclipse Combustion Automobile EGA4 User Manual

Instruction Manual 924-2  
11/1/03  
EGA4 Combustion  
Analyzer  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
INTRODUCTORY NOTE  
NOTE: THIS MANUAL IS VALID FOR INSTRUMENTS WITH SERIAL NUMBER 25865 AND FIRMWARE REV. 2.001 OR HIGHER  
This manual has all the information you need to install, operate and maintain the flue gas analyzers EGA4  
and its accessories.  
Eclipse has used the best care and efforts in preparing this book and believes the information in this  
publication are accurate. The Eclipse products are subjected to continuous improvements, in order to  
pursue the technological leadership; these improvements could require changes to the information of this  
book.  
Eclipse reserves the right to change such information without notice.  
The EGA4 gas analyzers uses sophisticated analogic and digital technologies. Any maintenance operation  
must be carried out by qualified personnel ONLY. Eclipse supplies instructions and operative procedures for  
any operation on the instrument. We recommend to contact our technicians for any support requirements.  
The instrument is supplied by a Ni-MH rechargeable battery pack or by 100, 115, 230V ±10% 50/60Hz line  
supply using the special power supply module provided with the instrument.  
Eclipse shall not be liable in any event, technical and publishing error or omissions, for any incidental and  
consequential damages, in connection with, or arising out of the use of this book.  
The operator must not use this equipment for any other purpose than that stated.  
This document is the property of Eclipse and may not be copied or otherwise reproduced, communicated in  
anyway to third parties, not stored in any Data Processing System without the express written authority of  
Eclipse.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
TABLE OF CONTENTS  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
1
GENERAL DESCRIPTION  
EGA4 is designed to satisfy the market needs; but they are the result of the advanced research and experience of  
Eclipse. EGA4 is a multigas compact palm-top multifunction instrument. The micro-processor based instrument includes  
a flue gas analyzer, an emissions monitor and an ambient parameters indicator. Two internal electrochemical sensors  
read the Oxygen (O2) and carbonic monoxide (CO) gas concentration. The gas temperature and air temperature are  
used in connection with the gas analysis to calculate the efficiency, excess air, and CO2 concentration. A 10 gas  
parameters programmable table is used for calculations approved in accordance with DIN33962.  
A third cell (NO or SO2) enables the pollution measurement. The NO concentration can be expressed in terms of NOx as  
required by ambient laws.  
External sensors are available for ambient parameters measurement: ambient relative humidity and temperature  
(T+RH%), ambient CO, to check and evaluate gas network leakage and natural gas leakage detector.  
EGA4 can install a forth electrochemical sensor to monitor pollution. In this way you can measure simultaneously and  
using a single unit, NO/NOx and SO2 gas concentration.  
The instruments are completed with a pressure (draught) sensor, an internal printer, an internal memory for storing data  
and a RS232 serial interface for configuration and data transfer from and to a PC.  
Draft measurement is possible using the internal pressure sensor and the special gas sample probe.  
The optional internal printer is impact type and the generated document is very legible and has a long time duration.  
The internal standard memory may store up to 250 complete gas analysis divided by Tag.  
The instruments have a standard IR serial interface and an optional RS232 conversion module and a configuration  
PC software are available to configure the analyzer.  
Features & Benefits  
New user friendly interface: very intuitive and in English  
language to use the instrument without instruction manual.  
Large dimensions and lighting LCD display: very legible  
using the “Zoom” function and the automatic back-light device.  
Easy and quick upgrading hardware and software are made  
using modular design to upgrade the system yourself.  
Differential pressure measurement: gas velocity, pressure,  
draft, P, etc.  
Averaging between three gas analysis.  
Internal impact type printer: more legible and long time  
duration for you documents.  
Single battery pack: rechargeable to power both the  
instrument and the printer.  
Internal memory: up to 250 complete data analysis.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
1.1  
Specifications  
Type: 2, 3 or 4 cells palm-top flue gas analyzer.  
Calibration: automatic calibration procedure at instrument switching-on.  
Self-diagnosis: Sensors efficiency test with anomalous status announcement.  
Fuel types: Up to 10 totally programmable.  
Pump: rate of flow 0.8 lit / head –230mbar  
All data measured using 3 meters long probe and line filter connected. Load loss = 10 mbar using a 3 meters probe  
extension  
Power supply: High capacity Ni-MH rechargeable battery pack / external battery charger.  
Charging time : 8h at 90% with instrument off.  
Battery life: 5h continuous operation (without printer and back-light).  
Printer: Impact type 24 columns with 58 mm large and 18 meters long paper roll  
Printer power supply: using the analyzer battery pack.  
Print autonomy: up to 30 reports with battery full  
Automatic CO(ppm) and CO(%) selector: if the sensors are installed.  
Internal data memory: up to 250 complete analysis data structured by Tags.  
Service and user data: 3 programmable lines for each programmed customer using a PC and DBGas Software.  
Report Herder: 4 rows x 16 characters programmable from keyboard  
Display: Large (40x56 mm) graphic LCD display with automatic back-light device. Bargraph and trend capability as  
option.  
Serial interface: Bi-directional infrared interface. External IR/RS232 converter available for PC communication.  
Synchronous serial port: for external keyboard and optical bar pen reader.  
Smoke measurement: Using the optional external manual pump. Bacharach index memory store and printout  
capability as standard.  
Optional probes: ambient CO, Bar pen, explosive gas leakage sniffer, T+RH% probe.  
Working temperature: from –5°C to +45 °C (up to 50°C for short time)  
Storage temperature: from –20 to +60°C (3 months maximum at temperatures exceeding the operational limits).  
Dimensions: 115x90x330 mm  
Weight: 1.1 kg battery and printer included  
External optional ambient CO probe  
Range: from 0 to 500ppm  
Accuracy: ±5ppm up to 100ppm; ±5% up to 500ppm  
Resolution: 1ppm  
Response time: 30s (t90)  
Waiting starting time: 30s  
Working temperature: from –5°C to +45 °C  
External optional ambient T+RH probe  
Temperature Range: from 0°C to 85°C  
Temperature Accuracy: ±1°C  
Temperature Resolution: 0.1°C  
Relative Humidity Range: from 0 to 99%RH  
Relative Humidity Accuracy: ±5%RH  
Relative Humidity Resolution: 0.1%RH  
Response time: 50s (t63)  
Waiting starting time: 30s  
Working temperature: from –0°C to +50 °C (up to 85°C tip only)  
External optional natural gas leak detection probe  
Pre-heating time: 30s minimum  
Alarms indication: visual with 5 steps  
5 alarms levels: 100, 200, 300, 400, 500 ppm  
Acoustic Alarm indication: respectively 1, 2, 3, 5 beep/s, continuous  
Response time: 5s (t90)  
Alarm levels Accuracy: ±10% at 90 days  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
1.2  
Accuracies and ranges  
Parameter  
Sensor type  
Range  
Resol.  
0.1%  
Max  
response  
20 sec.  
Accuracy  
±0.1% vol.  
±10 ppm <300 ppm  
±4% rdg up to 2000 ppm  
±10% rdg >2000 ppm  
±10 ppm <300 ppm  
±4% rdg up to 2000 ppm  
±10% rdg >2000 ppm  
±5 ppm <125 ppm  
O2  
CO  
Electrochemical  
from 0 to 25.0%  
from 0 to 8000 ppm  
H2 compensated up Electrochemical  
to 1000ppm  
1 ppm  
50 sec.  
CO  
NO  
NO2  
Electrochemical  
Electrochemical  
Electrochemical  
from 0 to 20000 ppm  
from 0 to 4000 ppm  
from 0 to 1000 ppm  
1 ppm  
1 ppm  
1 ppm  
40 sec.  
40 sec.  
50 sec.  
±4% rdg >125 ppm  
±5 ppm <125 ppm  
±4% rdg >125 ppm  
NOx  
SO2  
Calculated  
Electrochemical  
from 0 to 5000 ppm  
from 0 to 4000 ppm  
1 ppm  
1 ppm  
40 sec.  
±5 ppm <125 ppm  
±4% rdg >125 ppm  
CO2  
Tair  
Tgas  
T  
Tflow  
Treturn  
Pressure/Draft &  
P  
Calculated  
Pt100  
Tc K  
Calculated  
Tc K  
from 0 to 100%  
from -10 to 100 °C  
from -10 to 1000 °C  
from 0 to 1000 °C  
from -10 to 100 °C  
from -10 to 100 °C  
-10hPa to +100 hPa  
0.1 %  
0.1 °C  
0.1 °C  
0.1 °C  
0.1 °C  
0.1 °C  
0.01 hPa  
±(0.2% rdg+0.15°C)  
±(0.3% rdg+0.3°C)  
±(0.3%rdg+0.3°C)  
±(0.3% rdg+0.3°C)  
±1% rdg  
Tc K  
Piezo  
Excess air  
Efficiency  
Gas speed  
Smoke index  
Calculated  
Calculated  
Pitot tube  
from 1.00 to infinite  
from 0 to 100%  
From 0 to 100.0 m/s  
from 0 to 9  
0.01  
0.1 %  
0.1 m/s  
External pump  
Technical units and ranges can be converted directly from ppm to mg/Nm3 , mg/kwh and from hPa to mmH2O, mbar or inH2O.  
The relative accuracy shown are expressed as absolute or % of rdg errors at -5°C to +40°C ambient temperature.  
The maximum response time shown is referred to 90% signal changes.  
The pressure relative accuracy shown is valid only after the auto-zero procedure.  
Specifications may change without notice.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
2
GENERAL  
2.1  
Keypad & Display  
The tactile keyboard allows the operator to enter the main operative mode and all other complementary or auxiliary  
modes following the menu driven instructions.  
The high contrast graphic LCD (40x56 mm), equipped with an automatic back-light device, displays the measured and/or  
calculated parameters in the preferred format (Zoom function). The above parameters can be also displayed in a graphic  
mode.  
2.2  
Built-in printer  
EGA4 can be equipped with a built-in, rugged, impact type printer. It uses a low cost common roll of paper (58 mm large,  
18 meters long) , more readable, long time and heat resistant better than the thermal printout on chemical paper. One  
key instruction is enough to obtain one, two or more copies of the analysis report with header and company reference  
data.  
2.3  
Gas sampling probe  
Flue gas sampling probes with different length, shape and max. operating are available to match the requirement of  
different applications. The sampling probe is connected to the instrument with a rubber hose through a combined module  
of water trap and suspended particle filter.  
2.4  
Measuring cells  
EGA4 uses long life sensors for O2, CO (H2 compensated), NO, NO2 and SO2. An automatic device exclude  
automatically the CO sensor when CO high concentration level is identified.  
Four acoustic and visual alarms can be set on four programmable parameters.  
2.5  
Temperature probes  
A thermocouple type K is incorporated on the tip of the gas sampling probe to measure the flue gas temperature. This  
thermocouple is suitable for measurements up to 800°C (max 1000°C for few seconds). Temperature measurement and  
gas sampling from the flue gas pipe are thus always performed in the same site.  
The probe is connected to the instrument with the appropriate compensated cable and connector. A Pt100 resistance  
thermometer (local jig or remote sensor) is used for the air temperature measurement and best efficiency calculation.  
2.6  
Pressure sensor  
The instrument is equipped with an internal sensor for pressure and stack draught. One key instruction move the  
operative mode to and from this function to gas analysis and viceversa. The instrument has, as standard feature, a  
differential pressure sensor.  
2.7  
Fuel technical data  
The instrument includes as standard the technical data for 4 of the most common fuels.  
Using the optional GasConfig software, it is possible to modify or add data of up to 10 different fuels.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
2.8  
Smoke measurement  
Smoke index measurement is done by using a hand pump (supplied as an accessory), the results cam be memory  
stored and printed in the report.  
2.9  
Remote temperature probe  
A remote Pt100 probe is available for combustion air temperature measurement from –10°C to 100°C. This probe is  
strongly recommended mainly in forced air boiler to obtain an accurate calculation of the efficiency.  
2.10  
T+RH% probe  
Optional probe for simultaneous measurement of ambient temperature and relative humidity (%RH) for comfort index  
computation.  
2.11  
Ambient CO probe  
Optional probe to monitor CO concentration and therefore safety condition in the boiler room. The instrument gives  
acoustic and visual alarm if the set limit (according to the OSHA recommendation) are exceeded.  
2.12  
Natural gas probe  
Optional probe to monitor CH4 and natural gas concentration and detect and locate the position of a gas leak into the  
domestic pipe network.  
2.13  
Leakage checking mode  
To check gas network tightness using a pressure decay method at programmable interval time. It uses the internal  
pressure sensor and a Eclipse leakage procedure.  
2.14  
Burner pressure probe  
A 1 meter 8x4mm silicon hose is used to check the pressure inside the burner when you are installing the heating  
system.  
2.15  
Pitot tube  
The EGA4 analyzer can be connected to a Pitot tube for gas speed measurements.  
2.16  
Calibration certificate  
Each EGA4 portable gas analyzer, is factory calibrated and certified against Eclipse Standards, that are periodically  
certified by an International recognized Laboratory, and shipped with a Report of Calibration stating the nominal and  
actual values and the deviation errors.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
3
PHYSICAL DESCRIPTION  
The EGA4 portable analyzer consists of a rugged and compact case, a mother board with all base function circuits, 2, 3  
or 4 electrochemical cells, a gas pump, a keyboard, an LCD backlighted display, a Ni-MH rechargeable battery pack and,  
optionally an impact printer.  
The 2 pieces of the case are jointed by 8 screws. The batteries, the pneumatic circuit and the cells are positioned in the  
rear of the analyzer and 2 screws locked the lid.  
A pressure lid allows to remove the paper roll.  
Positioning cone  
Impact printer  
(opt.)  
Flue gas probe  
IR serial port  
Graphic Display  
Keyboard  
External probe input  
Battery charger  
Pt100 Tair probe  
Back-light sensor  
P1 – Draft/Pressure  
input  
P2 - P Input  
INLET – Flue Gas  
input  
Tgas Input  
Water trap + Line filter  
At the bottom of EGA4 you can see all sampling probe connectors: gas inlet, pressure and draught input, thermocouple  
input for gas measurement and the 2nd pressure inlet connector.  
On the left side are the connectors for: line power charger, synchronous serial input connector for bar pen and keyboard,  
the input for the auxiliary probes (T+RH%, leak checker, etc.) and the infrared LED for PC serial communication (an  
optional IR/RS232 and software should be used to configuring and transfer the analysis data).  
The operator interface is on the front of the instrument and it consists of: a high contrast LCD display and a 14 button  
keypad. An automatic back-light device and a “zoom” function, make easier the data reading on the display. The most  
used operation (analysis, draught, printing and smoke index) can be accessed by operator pressing a single key.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
4
PRINCIPLE OF OPERATION  
The EGA4 analyzer is based on the following functional blocks:  
2° Sensor CO  
Water trap  
Gas outlet  
Line filter  
Pump  
1° Sensoe O2  
4° Sensor  
3° Sensor  
Gas input  
INLET  
Differential  
pressure  
sensor  
P2 - P  
Pt100 Tair input  
External probe input  
P1 – Draft/Pressure  
TcK Tgas input  
MicroController  
250  
memory  
IR serial port  
Display  
Battery charger input  
Power supply  
Ni-MH battery  
Keyboard  
Impact printer  
4.1  
Measurement principle  
The gas is sampled and aspirated through the probe with a primary pump powered at constant voltage.  
To position the sampling probe in the exhaust gas pathway a hole of 11mm, up to 16mm, should be drilled and the  
retaining cone of the sampling probe firmly screwed in it.  
The retaining screw in the cone enables the probe to be easily moved to locate the core flow, normally correspondent to  
the center of the section of the smoke tube. The flue gas and exhaust gas pathway, should be checked for gas-tightness  
before carrying out a measurement and, if necessary, non gas-tight points should be sealed.  
The O2 sensor is essentially an electrochemical cell, with two electrodes and electrolyte solution. The behavior is similar  
to a normal battery and therefore the sensitivity decreases with time. The expected life does not relate to the operative  
time and is lost after approximately 24 months.  
The toxic gas measurements (CO, SO2, NO and NO2) use electrochemical cells, with an expected operative life of 3  
years.  
The electrochemical cell grants accurate results for time intervals of approximately 60 minutes. The zero drift is  
automatically corrected by the instrument every time the instrument is switched-on, using fresh ambient air as reference.  
This operation should be made with the sampling probe not inserted in the chimney or with the sampling probe  
pneumatic connector disconnected from the analyzer gas inlet.  
When a long time analysis has to be made, a new autozero procedure should be performed.  
The pressure/draught sensor is based on the principle of the extension metric measuring bridge. When the instrument is  
switched-on, a zero calibration of the draught/pressure circuit is also executed. Leave open the “P” connector during  
this phase.  
Measured and calculated parameters are indicated on a LCD alphanumeric display (40x56 mm), equipped with a  
automatic back light device for easy readings, also in poor light conditions.  
4.1.1  
Gas sampling probe  
The sampling probe consists of a steel tube and a handle of thermoinsulating material. A positioning cone allows to place  
the probe in holes with a diameter from 11 to 16 mm.  
The gas temperature is acquired using a thermocouple type K with the junction placed on the top of the tip.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
4.1.2  
Water trap & line filter  
The gas flows through an external combined water trap and line filter to avoid the presence of condensation and  
suspended solid particles in the analysis section of the instrument. A cylinder is positioned at 15 cm from the instrument  
gas inlet it is divided into two parts: the water trap and the line filter.  
The water trap works using the expansion principle: the gas flow decreases its speed inside the cylinder and it will cool;  
the humidity will condense and the solid particles fall down. The section of the water trap must be periodically drained off  
to avoid water from entering the analysis section. Pull the rubber plug and shake slowly the trap to drain the water. Push  
the rubber plug to close the trap hole.  
The line filter is positioned after the water trap and before the electrochemical cell. Its function is to stop the smallest  
solid particles before the analysis. Remember to change the filter every time it is dirty.  
Line filter  
cat. EE650074  
Rubber plug  
cat. EE650081  
WARNING  
THE WATER TRAP MUST BE KEPT IN VERTICAL POSITION DURING GAS SAMPLING. AN INCORRECT POSITIONING OF THE TRAP CAN  
ALLOW THE WATER TO ENTER INSIDE THE ANALIZER AND DAMAGE THE ELECTROCHEMICAL SENSORS.  
NEVER MAKE ANY ANALYSIS WITHOUT THE DRAINING RUBBER PLUG. THE MEASUREMENTS WILL BE INCORRECT.  
WHEN YOU FINISH THE ANALYSIS, REMEMBER TO DRAIN THE WATER TRAP. BEFORE PUTING THE GAS PROBE IN THE CARRYING CASE,  
REMUVE THE CONDENSATE WATER FROM THE PROBE HOSE.  
THE LINE FILTER SHOULD BE REPLACED WHEN DIRTY. NEVER MAKE ANY ANALYSIS WITHOUT LINE FILTER AND/OR WATER TRAP, AS IT  
CAUSES AN IRREVERSIBLE DAMAGE TO THE ELECTROCHEMICAL SENSOR.  
4.1.3  
Gas sensors  
The analyzer uses long life sensors for O2, CO (H2 compensated), NO, NO2 and SO2. The sensor do not need special  
maintenance but must be replaced after the expected lifetime.  
However a full maintenance and certification of the instrument is recommended at one year interval.  
The gas sensors are electrochemical cells composed by two electrodes (anode and cathode) and an electrolyte solution.  
The sampled gas goes trough a selective diffusion membrane.  
The oxidation process produces an output electrical signal proportional to the gas concentration. The signal is evaluated  
by the electronics, converted to digital, processed by the microprocessor, displayed and printed with a 0.1% volume  
resolution.  
The flue gas must not be at a pressure that could damage or destroy the sensor. Measurements are always carried out  
under "pressureless" conditions. The maximum permissible excess/reduced pressure is ±100 mbar.  
Each sensor has a different response time:  
O2  
20s to 90% of reading  
=
CO (H2 comp.) = 50s to 90% of reading  
CO  
NO  
NO2  
= 50s to 90% of reading  
= 40s to 90% of reading  
50s to 90% of reading  
=
SO2  
= 40s to 90% of reading  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
NOTE: TO OBTAIN AN ACCURATE MEASURE IT IS RECOMMENDED TO WAIT 3/5 MINUTES.  
Toxic gas sensor can be present a ±2% drift and a long resuming time it an excessive (>150% of F.S.) gas concentration  
is applied. In that case it is recommended to wait for a measured value lower than 20ppm, by sucking fresh air before  
switch the analyzer off.  
An optional Electro-valve can be installed inside the instrument to exclude/include manually or automatically the CO cell  
when the CO concentration is too high (e.g. when the burner is starting)  
Four acoustic and visual alarm levels can be set on four programmable parameters.  
4.2  
Auxiliary measurements  
4.2.1  
Temperature measurements  
The instrument is equipped with two temperature inputs to measure exhaust gas and the burner air input temperatures  
(combustion gas).  
A thermocouple type K (nickel-nickel chromium) is included in the tip of the gas sampling probe to measure the flue  
gas/exhaust gas temperature. This thermocouple is suitable for permanent measurements at temperatures up to  
800°C and for short-term measurements up to 1000°C. Temperature measurement and gas sampling from the flue  
gas pathway are thus always performed at the same site. The probe is connected to the apparatus with  
compensated cable and connector. An internal Pt100 resistance thermometer is used for cold junction  
compensation.  
The same Tc K input can be used to measure the flow and return temperature in water circuit. If you have to  
measure the water temperature measuring the pipe temperature, use an arch-model thermocouple with an  
appropriate diameter.  
A remote Pt100 sensor, can be supplied on request with a 2 or 5 meter cable to measure the air inlet temperature in  
forced air boiler. This option is very important for an accurate efficiency calculation.  
4.2.2  
Pressure and Draft  
The analyzer can be equipped with a temperature compensated pressure sensor to measure the chimney draft or  
pressure. The pressure range is from –1500.0 to + 1500.0 mmwc (±150.00 hPa)  
The sensor is factory calibrated and does not require manual adjustment.  
The zero drift, caused by ambient air temperature variation, is automatically cancelled at each instrument start-up. In  
addition, for more accurate readings the operator can reset, using the pertinent key, the zero if required. The instrument  
sensor is differential type and, if connected to a Pitot tube, it can be used to measure gas speed.  
NOTE:  
WE SUGGEST TO EXECUTE THE AUTOZERO PROCEDURE FOR MORE ACCURACY BEFORE PERFORM THE MEASUREMENT.  
CAUTION  
IF A SINGLE TUBE GAS SAMPLING PROBE IS USED FOR PRESSURE/DRAFT MEASUREMENTS, BE SURE THAT IT IS CLEAN AND DRY  
BEFORE CONNECTION TO THE PRESSURE INPUT.  
CAUTION  
A +300HPA (OR –300HPA) OVER-PRESSURE CAN PERMANENTLY DAMAGE THE PRESSURE SENSOR.  
4.2.3  
Smoke index measurement  
This method consists of taking a gas sample from the center of the gas pipe behind the heat exchanger and crossing it  
through a special filter paper.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
The color of the spot on the filter is compared with a graduated (from 0 to 9) reference scale and it is called “smoke  
index”.  
You can type in the instrument up to 3 smoke index values; the analyzer calculate the average value and can print these  
values on the report.  
Normative and laws about the air pollution, describe the procedure: DIN51402, 2116, 2117 and 2297 VDI directives,  
ASTM D 2156-63 T, etc.  
4.2.3.1  
Measuring instruments (option)  
1. Smoke pump: it should suck 5.75 litres ±0.25 l (normalized to 0°C, 760mmHg) through a 1 cm2 filter.  
2. Smoke index reference table: it is a grey scale sheet with 10 different areas numbered from 0 to 9. The number 0  
corresponds to a 85% ±2.5% reflection. Every area reflects 10% less than the previous one. The scale is used to  
compare the scale with the paper filter and to calculate the smoke index.  
3. Paper filter: When it is clean it has a reflection corresponding to the 0 scale index. It also has 3 litres per cm2 a  
minute (normalized to 0°C, 760mmHg) with a 200/800 mmwc resistance to the air flux.  
4.2.4  
Other measurements  
The analyzer has an auxiliary input for special probes connections. Available probes are: ambient CO monitoring,  
temperature & humidity (T+RH%) measurement and natural gas monitoring probes.  
An optional operative mode is the leakage pipe test to check gas network tightness using pressure decay method at  
programmable interval time.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
5
RECOMMENDATIONS  
The analyzer should be used in environments where the temperature is between -5°C and +45°C.  
When the analysis are completed, before switch the instrument off, remove the probe from the gas pathway and wait  
about 30 seconds cleaning the pneumatic circuit from gas.  
Do not use the analyzer with clogged filters or filled with humidity.  
Before placing the probe in the case, be sure that the probe, the water trap and the hose are clean and cold.  
If you have ordered a double hose sampling probe, insert both connectors to the instrument during the gas analysis  
(pay attention to color correspondence).  
To empty the water trap from the condensate water, remove the draining plug. DO NOT OPEN the water trap. DO  
NOT leave the water trap without the draining rubber plug.  
For the best efficiency and accuracy, we suggest to calibrate the instrument every year.  
WARNING  
IF THE EGA4 IS STORED AT TEMPERATURE EXCEEDING THE OPERATIVE LIMITS, THE ANALYZER NEEDS SOME MINUTES TO WARM-UP  
TO THE ACTUAL AMBIENT TEMPERATURE, BEFORE STARTING THE OPERATION.  
5.1  
Power supply  
The instrument can be powered from:  
internal rechargeable Ni-MH battery.  
External battery charger, supplied as a standard accessory (the batteries must be installed).  
Optional external DC auto battery charger (the batteries must be installed).  
The Ni-MH rechargeable batteries allows a long time operation and do not need maintenance. The same batteries power  
both the instrument and the internal printer. The internal battery will grant 5 hours continuous operation (without printing  
and display back light off).  
NOTE: 90% BATTERY CHARGING CAN BE OBTEINED IN 8 HOURS WITH THE INSTRUMENT SWITCHED OFF.  
During operation a fully battery symbol “” will be displayed on the display. This symbol means that the batteries are  
completely full. When the batteries will be discharged the symbol “” will appear and the instrument still has about 20  
minutes operation capability to end the running analysis.  
The battery symbol indicates that a full charge is required. Use only the dedicated battery charger supplied by Eclipse  
together the instrument.  
CAUTION: OLD BATTERIES CAN LEAK AND CAUSE CORROSION. NEVER LEAVE RUN DOWN BATTERIES IN THE INSTRUMENT  
WARNING  
THE INSTRUMENT IS SHIPPED WITH AN AVERAGE LEVEL OF BATTERY CHARGE. AFTER UNPACKING, A FULL CHARGE OF THE BATTERY  
IS RECOMMENDED, BY CONNECTING THE INSTRUMENT TO THE MAIN LINE THROUGH THE BATTERY CHARGER (OFF CONDITION) FOR  
8/10 HOURS.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
6
CONNECTIONS  
6.1  
Electro-pneumatic connections  
To prepare the instrument for operation connect the sampling probe to the instrument:  
Plug the pneumatic connector of the probe to the GAS INLET connector. If you are using the gas sampling probe  
with Draft option, connect also its connector to the instrument Pressure/Draft inlet.  
Plug the probe temperature sensor plug to the pertinent connector.  
For more accurate readings and efficiency calculations, plug the remote air temperature Pt100 sensor to the 3 pin  
connector on the left side of the instrument.  
Tgas input  
INLET – gas input  
P1 – Draft/Pressure  
input  
P2 – differential  
pressure input  
pneumatic ports  
Battery charger  
Pt100 Tair input  
RS232 – External  
probes input  
IR serial interface  
Right side  
6.2  
Gas probe positioning  
The measurement site should be arranged at a distance of 2xD behind the exhaust gas connection pipe, where D =  
diameter of the exhaust gas connection pipe.  
To position the sampling probe in the exhaust gas pathway a hole of 11/16mm should be drilled and the retaining cone of  
the sampling probe firmly screwed in it.  
The retaining screw in the cone enables the probe to be easily moved in order to locate the core flow, normally  
correspondent to the center of the section of the stack.  
The flue gas and exhaust gas pathways, must be checked for gas-tightness before carrying out a measurement and, if  
necessary, non gas-tight points should be sealed.  
To locate the gas core flow, insert progressively the sampling probe and read the maximum value of temperature.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Tair probe  
CAUTION  
FOR A CORRECT GAS ANALYSIS, NO AIR MUST REACH THE FLUE GAS AS A RESULT OF NON-GAS-TIGHT CONNECTION POINTS BETWEEN  
THE HEAT PRODUCER AND THE MEASUREMENT SITE (PROBE).  
THE FLUE GAS AND EXHAUST GAS PATHWAYS MUST BE CHECKED FOR GAS-TIGHTNESS BEFORE CARRYING OUT A MEASUREMENT,  
AND IF NECESSARY NON-GAS-TIGHT POINTS SHOULD BE SEALED.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
7
OPERATIONS  
7.1  
Basic operation  
All the procedures and programming operations on the EGA4, can be made using the keyboard and the display.  
NOTE: ALL NUMERIC VALUES SHOWN IN THE FIGURES OF THIS MANUAL ARE INDICATIVE AND LISTED AS AN EXAMPLE.  
The analyzer should be used in environments where the temperature does not exceed the specified limits (from -5°C to  
+45°C) and where the relative humidity is lower than 95% non-condensing.  
7.1.1  
Keyboard  
The front panel keys functions are the following:  
[F1] and [F2]  
This keys are multifunction. The instrument  
change the assigned function during the  
operations. All displayed pages have, in the  
bottom, 2 boxes each containing the assigned  
function (e.g. ANALYSIS ). If no word is  
displayed inside the box, no function is assigned  
to that function key.  
F1  
F2  
S
T
W
X
F1  
F2  
[S], [T], [W] and [X] They move the cursor symbol or to increase or  
decrease numerical values.  
[ENTER]  
Accept and memory store the modified  
parameter or variable.  
ENTER  
ON/OFF  
PRINT  
[PRINT]  
Print the report of the analysis.  
[ON/OFF]  
[STORE]  
Switch the analyzer on or off.  
Read or store the analysis data from or in the  
memory.  
STORE  
HELP  
SETUP  
DRAFT  
MENU  
[SETUP]  
[MENU]  
Go to the configuring page of the instrument.  
Go to the auxiliary function (Ambient  
measurements, Flow and return Temperature,  
etc.) menu.  
SMOKE  
[DRAUGHT]  
[SMOKE]  
Go to the Pressure/ Draught measurement.  
Allows the data input for smoke index  
measurements. You need an external pump for  
the gas sampling.  
[HELP]  
Display the most important information for the  
service: the battery charging level, the status of  
the gas sensors, the free memory, etc.  
7.1.2  
Display  
The EGA4 is designed with a large (40x56 mm) graphical display using an automatic back light system for the best  
reading in poor light conditions also. The instrument is able to visualize simultaneously on the display 3, 6 or 12  
parameters.  
Three different area can be identified on the display: Menu and Measure area, Status bar and Function boxes.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Menu&Measure area  
Status bar  
O2 : 20.9 %  
CO : 2000ppm  
Ta : 20 °C  
Tg : 400 °C  
SO2 : 1000  
CxHy: 5.00  
Lam : 0.99  
NO2 : 100  
η : 95.7 %  
NOx: 500ppm  
CO2 : 10.2  
Per : 10.5  
GRAPH  
Ref O2  
Function box  
The Menu and Measure area displays the analysis data, the menu and all messages for the operator. The measured and  
calculated parameters are displayed in different pages of 6 parameters each.  
Using the [S] and [T] keys you can change page, changing the displayed parameters.  
Pressing the [W] and [X] keys it is possible to increase or decrease the number of the displayed parameters (ZOOM  
function).  
O2 : 20.9 %  
O2 : 20.9%  
CO : 2000p  
Ta : 20.2°C  
Tg : 400.3°C  
η
: 95.7%  
NOx: 500p  
SO2 : 1000p  
CxHy: 5.00  
Lam : 0.99  
NO2 : 100p  
CO2 : 10.2p  
Per : 10.5  
O2 20.9%  
CO 2000ppm  
Ta 20.0°C  
CO : 2000 ppm  
Tamb : 20 °C  
Tgas : 400 °C  
Eff : 95.7 %  
NOx : 500 ppm  
GRAPH  
GRAPH  
GRAPH  
Ref O2  
Ref O2  
Ref O2  
Two boxes are positioned on the bottom of the display. They contains the name of the function assigned to the [F1] and  
[F2] function keys.  
The status bar uses graphical symbols to describe the actual operation mode of the instrument.  
/ ≠  
Battery status: =charged, =discharged  
Max/Min/  
Med/Mem  
The Max, Med, Min, Actual values are displayed in memory recalling mode.  
O2  
The displayed measure are referred to oxygen  
Memory Card (PCMCIA) inserted.  
Line operations  
7.1.3  
Display adjustment  
In autozero procedure, you can press the [W] and [X] keys to adjust the LCD contrast.  
When the instrument is in measuring mode you should press the [HELP] key and press the [W] and [X] keys to adjust  
the LCD contrast.  
7.1.4  
Numerical input  
If you have to set a numerical parameter (e.g. O2 reference, etc.) use the following procedure:  
Select the parameter to be changed (e.g. O2 reference) with the [S] and [T] key from the configuring menu.  
Press [ENTER] to enter in modify page as follows:  
CO Reference  
0.0  
ESCAPE  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
The “S” symbol below the first digit is the cursor.  
You can move the cursor between the digit using the [W] and [X] keys.  
You can change the selected digit using [S] and [T]. If “9” or “0” values are exceeded, the left digit is increased or  
decrease.  
Press [ENTER] to memory store the value and return to the previous page.  
Press [ESCAPE] (F1) to return to the previous page without save the changes.  
7.1.4  
Text input  
If you have to set a text parameter (e.g. customer name, etc.) use the following procedure:  
Select the parameter to be changed (e.g. customer name) with the [S] and [T] key from the configuring menu.  
Press [ENTER] to enter in modify page as follows:  
!"#$%&'()*+,-./0123  
456789:;<=>?@ABCDEFG  
C
HIJKLMNOPQRSTUVWXYZ  
ESCAPE  
CONFIRM  
A “S” symbol below the “ “ (blank) character in figure, represent the cursor. It is used to identify the selected character;  
you can move it using the [W], [X], [S] and [T] keys. The box below the characters table shows the currently inserted  
text. The symbol “W” is the end of line symbol.  
Press [CONFIRM] to write in the line box the selected char. The reversed char “C”, when selected, delete the last  
inserted char.  
Press [ENTER] to memory store the text and return to the previous page.  
Press [ESCAPE] to return to the previous page without save the changes.  
7.1.5  
Select by a list  
If you have to set a text parameter (e.g. Tag name, fuel type, etc.) use the following procedure:  
Select the parameter to be changed (e.g. fuel type) with the [S] and [T] key from the configuring menu.  
Press [ENTER] to enter in modify page as follows:  
-- Fuel --  
Natural Gas  
LPG  
Gasoil  
Combustible oil  
ESCAPE  
The “X” symbol on the left is the cursor.  
You can move the cursor between the digit using the [S] and [T] keys.  
Press [ENTER] to memory store the selection and return to the previous page.  
Press [ESCAPE] (F1) to return to the previous page without save the changes.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
7.2  
Flue gas analysis  
Connect the gas probe to the analyzer as shown in chapter 7. DO NOT INSERT THE PROBE IN THE CHIMNEY.  
Switch the analyzer on pressing the [ON] key. The display will show the following page:  
EcoLine 4000  
GreenLine 4000  
UniGas 3000+  
Num. Serie:  
1257  
Num. Serie:  
1257  
Num. Serie:  
1257  
Versione:  
1.000  
Versione:  
1.000  
Versione:  
1.000  
This page changes automatically after same seconds or if you press a key as follows:  
! Don t insert  
! probe in chimney  
!
!
Op.: Antonio  
Bat: 5.2V (23.5°C)  
Autozero: 180 sec  
MEASURE  
MENU  
This page displays the following information: operator name, battery charge level, instrument internal temperature  
and the seconds to end the autozero procedure.  
NOTE: THE ANALYZER MUST DRAW CLEAN AIR FROM THE AMBIENT DURING THE AUTOZERO PROCEDURE. OTHERWISE THE  
MEASUREMENTS CANNOT BE ACCURATE.  
It is possible to enter in “MENU” page (pressing [F1]) or in “MEASURE” page (pressing [F2]). See the appropriate  
paragraphs for operations.  
When autozero procedure finished, an intermittent sound advise the operator. Press the [ENTER] key to mute the  
unit. The following page will be displayed:  
! Now insert  
! probe in chimney  
!
!
--- FUEL --  
Natural Gas  
TAG SELECTION  
ANALYS.  
This page allows the operator to change the fuel used and to select the Tag between the available.  
Fuel selection. Move the cursor symbol “X” on the desired row using the [S] and [T] keys. Press [ENTER] to  
change the value. See instruction on paragraph 8.1.6.  
Tag selection. Move the cursor symbol “X” on the desired row using the [S] and [T] keys. Press [ENTER] to  
change the value. A new page will be shown. The Tag name, the description and the progressive number will  
be displayed. See instruction on paragraph 8.1.6. When in measuring mode, you can select another Tag  
pressing the [MEMORY] key.  
Insert the probe in chimney. Stop it using the retaining cone and adjust the immersion depth for a gas sampling in  
the middle of the exhaust gas connection pipe.  
Press the [ANALYSIS] (F1) key to begin the measurements. The following page will be shown:  
O2  
20.9 %  
0.0 %  
1 ppm  
1 ppm  
Tc Error  
--------  
CO2  
CO  
NO  
Tf  
Eff  
GRAPHIC  
Ref O2  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Pressing the [W] and [X] keys, it is possible to zoom-in and zoom-out increasing or decreasing the number of displayed  
parameters.  
O2  
Ta  
Tf 400.3C : NO2  
95.7%  
CO2 10.2p :  
NOx 500p :  
20.9% : CO  
20.2C : Eff 0.99  
2000p  
O2  
CO2  
CO  
20.9%  
0.0%  
100p  
η
:
1ppm  
GRAPHIC  
GRAPHIC  
Ref O2  
2
Ref O  
Pressing the [S] and [T] you can change page for others parameters.  
Pressing the [REF. O2] key the measured parameters will be referred to the programmed oxygen value. When selected  
this mode, the symbol “O2” will be displayed on the status bar.  
O2  
CO2  
CO  
20.9%  
0.0%  
1ppm  
GRAPHIC  
Ref O2  
If the graphical option (Table E=4 on ordering code) is installed, the instrument can display the measured values as bar-  
graph. Press the [GRAPHIC] (F2) key to change mode.  
O2  
CO  
η
NUMERIC  
Ref. O2  
Using GasConfig Software, you can program the graph page: Assign up to 6 different parameter, range and increment  
direction. See chapter 9 for software instructions.  
Press the [NUMERIC] (F2) key to return to the normal display mode.  
7.3  
Pressure/Draught measurement  
If the internal pressure sensor is installed (Table E=2 on ordering code), you can execute the pressure/draft  
measurements using or the standard probe or the special probe.  
Standard probe (TG models):  
The standard probe has a single gas collector for gas sampling. Usually you have the hose terminal connected to the  
instrument gas inlet; when you have to do the draft measurements you have to move the connector to pressure inlet (P  
IN) connector.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
CAUTION  
IF A SINGLE TUBE GAS SAMPLING PROBE (TG MODEL) IS USED FOR PRESSURE/DRAFT MEASUREMENTS, BE SURE THAT PROBE AND  
HOSE ARE CLEAN AND DRY BEFORE CONNECTION TO THE PRESSURE INPUT.  
Special draft probe (TGD models):  
This special probe model has a double gas collector: one for the flue gas analysis and one for the draft measurement.  
When you connect the probe to the analyzer you have to insert both gas inlet and pressure inlet connectors. Connect the  
hose with line filter to gas inlet connector.  
The pressure measurement requires the instrument in normal operating conditions indicating one of the measured or  
calculated parameters. Press [DRAUGHT] on the keyboard. DO NOT INSERT THE PROBE IN THE CHIMNEY. The  
internal pump will stop and the following page will be shown:  
For draught meas.  
Move probe on  
DRAUGHT P1  
Press [F1] to  
Start measure  
DRAUGHT  
ESCAPE  
Press [MEASURE] (F1) to show the following page:  
DRAUGHT  
Measure  
1.0 mbar  
Press [ENTER] to  
Hold measure  
ZERO  
ESCAPE  
Press the [ZERO] key before insert the probe in the chimney to zeroing the measured value.  
Insert the probe in the chimney. Check for mechanical positioning and flue gas intercepting. Wait for measurement  
stabilization.  
Press [ENTER] to memory store the pressure and draft values.  
Press [ESCAPE] (F1) to return to the previous page.  
Now you can proceed with the Smoke index measurement and/or the gas analysis. The memory stored value will be  
printed together the analysis.  
7.3.1  
Burner pressure measurement  
Using the burner pressure probe, it is possible to measure the pressure on the burner. Connect the probe to the  
instrument pressure input and connect to the burner plug. Follow the procedure described in paragraph 8.4 to read the  
pressure.  
7.4  
Smoke measurement  
To avoid condensation inside the smoke pump, it should aspirate ambient air before the gas sample. This can be  
obtained aspirating the air by the fireside (not in the exhaust gas connection pipe) without using the paper filter.  
Introduce now the filter in the pump. The gas sample should be drawn to the center of the combustion gas flux. The  
correct gas volume is sampled with 10 uniform shoots by the pump.  
Compare the darkening of the filter with the smoke index table. The smoke index found does not exceed the ones  
defined by the current normative.  
We suggested to use a retaining cone during gas sampling.  
NOTE:  
IF YOU WONT TO PRINT THE SMOKE INDEX WITH THE ANALYSIS DATA, YOU SHOULD DO THE MEASUREMENT BEFORE THE  
FLUE GAS ANALYSIS.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
7.4.1  
Input of the smoke index  
Before input the data, you have to execute the smoke index measurements. You can input up to 3 values; the analyzer  
will do the average calculus.  
The smoke measurement requires the instrument in normal operating conditions indicating one of the measured or  
calculated parameters. Press [SMOKE] on the keyboard. The following page will be shown:  
SMOKE  
Meas. 1: -  
Meas. 2: -  
Meas. 3: -  
AVG  
-
Oil.Der.: NO  
ESCAPE  
Press [S]and/or [T] to move the cursor symbol to the “Measure 1” input field.  
Press [ENTER] to input the value. See instruction on paragraph 8.1.4.  
If necessary, input the “Measure 2” and “Measure 3” smoke index. The instrument will compute the average.  
Press [S] and/or [T] to move the cursor symbol to the “Oil derivative”.  
Press [ENTER] to change the value for the correct fuel type.  
Press [ESCAPE] (F1) to return to the previous page without save the changes.  
Press [ENTER] to memory store the selection and return to the previous page.  
7.5  
Combustion air temperature (option)  
It is important to measure the true combustion air temperature to have a correct boiler efficiency computation. The EGA4  
has a auxiliary Rtd input to measure simultaneously the air temperature. A Pt100 with a 6 meters long cable can be  
connected on the right side of the analyzer.  
Insert the Rtd inside the air combustion aspiration tube and near the boiler.  
Follow the standard procedure to make measurements. The instrument will show the temperature on the display and the  
efficiency will be calculated using this value. If no external Rtd is connected, the analyzer will measure the instrument  
temperature (ambient) using the internal sensor.  
7.6  
Flow/Return temperature  
Connect the thermocouple type K on the bottom of the instrument (the same connector used for gas temperature). If the  
temperature measurement is made using the contact method on the external side of the flow and return water pipe. In  
this case, we suggest to use an arch type thermocouple.  
Press [MENU] to display the following page:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
GAS VEL.  
ESCAPE  
Use [S] and [T] to move the cursor symbol to “T. Flow/Return” option  
Press the [ENTER] key to display the following page:  
FLOW/RETURN TEMP  
Temper.: 40.0 °C  
Flow...: 40.0 °C  
Return.: --.- °C  
Differ.: --.- °C  
COPY  
ESCAPE  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
On the “Measure” field, the instrument will display the current temperature value measured using the connected  
thermocouple. The error message “Tc open” will be displayed if the thermocouple is not connected or broken. Positioning  
the thermocouple on the flow pipe.  
Use the [S] and [T] to move the cursor symbol to “T. Flow” field.  
Press [COPY] to copy the current temperature as T. Flow value.  
Press [ENTER] to manually change the temperature value  
Positioning the thermocouple on the return pipe.  
Use the [S] and [T] to move the cursor symbol to “T. Return” field.  
Press [COPY] to copy the current temperature as T. Return value.  
Press [ENTER] to manually change the temperature value  
The instrument will show the difference between the two values.  
Press [ESCAPE] (F1) to return to the previous page. The temperature values will be printed on the ticket report.  
7.7  
Gas speed measurement  
The EGA4, is arranged for chimney speed measuring. For this measurement you need a Pitot tube to be connected to  
the differential pressure inputs.  
Connect the “+” terminal of the tube to “P1” connector and the “-“ terminal the “P2” the instrument connector.  
Press [MENU] to display the following page:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
GAS VEL.  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “Gas Vel.” Option. Press the [ENTER] key.  
Gas Vel.  
Temp. : 40.0 °C  
Tg  
DP  
: 0.0 °C  
: --.- mmH2O  
Vel. : --.- m/s  
COPy  
ESCAPE  
Insert the gas probe in the chimney. Set the probe tip to the center of the pathway. The display will show the current  
gas temperature. An error message “Tc open” will be displayed if the thermocouple is not connected or broken.  
Use the [S] and [T] keys to move the cursor symbol to “Tg” parameter.  
Press [COPY] to copy the current temperature as Tgas value  
Press [ENTER] to manually change the gas temperature value  
Extract the gas probe from the chimney. Insert the Pitot tube inside the chimney. Be care that the probe is parallel to  
chimney axis and facing burner.  
Use the [S] and [T] keys to move the cursor symbol to “P” parameter.  
Press [COPY] to copy the current P value.  
Press [ENTER] to manually change the P value.  
The instrument will display the gas speed.  
Press [ESCAPE] to the previous page menu.  
NOTE: FOR THE BEST SPEED CALCULATION, DO NOT CHANGE THE BURNER RATE BETWEEN THE TWO MEASUREMENTS. THE  
OPTIMUM CONDITIONS WILL BE ACHIEVED USING 2 HOTELS IN CHIMNEY AND THE SIMULTANEOUS MEASUREMENTS  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
7.8  
Analysis data print  
An internal impact printer can be installed as an option in the instrument. Read paragraph 8.10 for header report  
changing.  
To print the report (ticket) of the analysis use the following procedure:  
Before make all measurements you need: Smoke index, pressure and draught, T. flow, etc. After make the gas  
analysis measurements and wait same seconds for measurement stabilizing. Press the [PRINT] key. The following  
page will be displayed:  
PRINT  
MEASURE HOLD  
PRESS [PRINT]  
NO. COPY  
MODEL  
1
Standard  
FEED  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “NO. copy” or “Model” field.  
Press the [ENTER] key to change the number of the reports you have to print and/or the print model for the report.  
Press the [PRINT] key again to print the report. You can abort the printing in progress by pressing the [ESCAPE]  
key.  
Press [ESCAPE] (F1) to abort the operation.  
Press [FEED] for paper advance. You can stop the paper advance by pressing the [ESCAPE] key.  
7.8.1  
Paper and Ribbon change  
Open the cover pressing as in figure.  
Extract the exhausted paper roll. You can use standard paper roll but you have to check before for its dimensions (max.  
57mm ±1mm large and 48mm ±1mm roll diameter).  
If necessary substitute the ribbon cartridge.  
Approach the end of the new paper roll to the slot under the printer.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Switch the analyzer on.  
Keeping the [HELP] key down; press the [X] key to bypass the autozero procedure.  
Press [PRINT] then press the [FEED] key for paper feed. Press the [ESCAPE] key when the paper will came out for  
same centimeters.  
Close the cover inserting the paper end in its slot.  
7.9  
Pressure decay procedure (option)  
This optional operative mode allows to find pipes leakage. To set and run leak test, press the [MENU] key from  
measuring page. The following page will be displayed:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
GAS VEL.  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “MEASURE” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
MEASURE  
P DECAY LEAK TEST  
GAS LEAK TEST  
AMBIENT CO  
ENVIRON. TEMP/HUM  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “P DECAY LEAK TEST” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
P DECAY LEAK TEST  
Leng.: max. 10 mt  
Type : Under Track  
Diam.: 1/2 "  
TEST RESULT  
ESCAPE  
TEST  
Before start the test you have to define the plant data:  
Leng.:  
Type :  
Diam.:  
Length of pipes  
Type of plant (Under track or Visible)  
Pipes diameters (from ½” to 1”½ settable)  
Use the [S] and [T] keys to move the cursor symbol to the specification to be changed. Press the [ENTER] key to  
modify. Press [ESCAPE] (F2) to return to the previous menu.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Use the [S] and [T] keys to move the cursor symbol to the value to be changed. Press the [ENTER] key to store the  
new selection.  
Select “TEST RESULT” option for results viewing and press the [ENTER] key.  
Now you can connect the instrument Pressure inlet (INP) connector to the gas circuit.  
CAUTION  
BE SURE FOR EMPTY AND CLEAN CIRCUIT: OVERPRESSURE, DUST, LIQUID AND CONDENSING MAY DAMAGE THE  
INSTRUMENT INTERNAL CIRCUITS.  
With circuit depressurized, press the [TEST] key. The unit will display the following page:  
SELECT TEST  
0.2 mmH2O  
Result:  
START TEST  
A
ESCAPE  
ZERO  
Press the [ZERO] key to reset the reading.  
The 4000 series can memory store up to 2 different test data (A and B) for “Before” and “After” check.  
Use the [S] and [T] keys to move the cursor symbol to “Result” option. Press the [ENTER] key to select the option.  
Use the [S] and [T] keys to move the cursor symbol to the value to be changed. Press the [ENTER] key to store the  
new selection.  
Select “START TEST” option and press the [ENTER] key to run the decay leak test.  
P1 : 100.0 mmH2O  
P2 :  
99.5 mmH2O  
P3 : _____  
P4 : _____  
~P : _____  
Result A: _____  
300  
ESCAPE  
The unit will store 4 different measurements at programmed time (standard values are: 10, 60, 120 and 120 second).  
See paragraph 10.2.4 to change these values.  
The instrument will display the P (P1-P4) value and it compute, using the circuit specifications (Length, Diameter and  
Type) the test result (GOOD or FAIL).  
Test result will be calculated using the following acceptance limits table:  
Under track circuit  
Visible circuit  
1”  
Diameter  
[in]  
½”  
¾”  
1”  
1” ¼  
1” ½  
½”  
¾”  
1” ¼  
1” ½  
Length  
< 10m  
< 20m  
< 30m  
< 40m  
< 50m  
> 50m  
3.5  
2.85  
2.7  
2.35  
2.1  
3
2.75  
2.2  
1.5  
1.2  
1.1  
0.9  
2
1.75  
1.1  
0.85  
0.4  
0.3  
0.3  
35  
28.5  
27  
23.5  
21  
30  
23.5  
22  
17  
14  
27.5  
22  
15  
12  
11  
9
20  
14  
11  
9
3
3
17.5  
11  
8.5  
4
3
3
2.35  
2.2  
1.7  
1.4  
1.4  
1.4  
1.1  
0.9  
0.3  
0.3  
1.85  
18.5  
14  
Note: These values are expressed in mmH2O. The plant circuit is failed when (P1-P4) exceed the values after 5  
minutes.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
7.10  
Ambient CO probe (option)  
This optional external probe allows ambient CO monitoring for personnel safety. When connected to the analyzer, it  
monitor continuously CO concentration and it signal when the Long-term Exposure (TWA) limits are reached. An  
acoustic and visible signals are emitted by unit.  
The following page show the current exposure limits for CO gas. This table is a guidance only, and figures must be  
checked before being used. Sensors used in safety applications should be fully calibrated at least every six months.  
U.K.  
HSE  
50  
GERMANY  
DFG  
USA  
OSHA  
35  
TWA (8h)  
30  
STEL (10’)  
300  
60 (30)  
200  
7.10.1  
CO probe operations  
To enable CO monitoring press the [MENU] key from measuring page. The following page will be displayed:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
AMBIENT ANALYSIS  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “MEASURE” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
MEASURE  
P DECAY LEAK TEST  
GAS LEAK TEST  
AMBIENT CO  
ENVIRON. TEMP/HUM  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “AMBIENT CO” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
Connect the probe to the unit and wait for the following page:  
AMBIENT CO  
Amb. CO:  
7 ppm  
ESCAPE  
ZERO  
NOTE: WHEN PROBE IS CONNECTED THE INSTRUMENT BEGIN A 40 SECONDS WAITING TIME. IF PROBE IS CONNECTED IN AMBIENT  
CO MENU, A WAITING MESSAGE WILL BE DISPLAYED.  
Before insert the probe in working area, agitate it for same seconds in fresh and uncontaminated air. Press the [ZERO]  
key to reset the measure and start CO monitoring.  
From this moment the unit will compare the monitored value with the CO limit (default OSHA limit: 35ppm). It is possible  
to change the CO limit using the GasConfig software for PC.  
Press [ESCAPE] (F2) to return to the previous menu.  
NOTE: IF THE PROCEDURE ABOVE IS EXECUTED AND THE CO PROBE REMAIN CONNECTED, THE INSTRUMENT WILL MONITOR AMBIENT  
CO ALSO DURING OTHER OPERATIVE MODE.  
If alarm condition is marked, press the [ENTER] key to silence it.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
7.11  
Natural gas leak checker (option)  
To enable natural gas monitoring press the [MENU] key from measuring page. The following page will be displayed:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
AMBIENT ANALYSIS  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “MEASURE” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
MEASURE  
P DECAY LEAK TEST  
GAS LEAK TEST  
AMBIENT CO  
ENVIRON. TEMP/HUM  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “GAS LEAK TEST” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
Connect the probe to the unit and wait for the following page:  
GAS LEAK TEST  
CH4:  
[1 box= 100ppm]  
Agitate the probe in  
Fresh air and press  
[ZERO]  
ESCAPE  
ZERO  
NOTE: WHEN PROBE IS CONNECTED THE INSTRUMENT BEGIN A 60 SECONDS HEATING TIME. IF PROBE IS CONNECTED IN GAS LEAK  
TESTPAGE, A WAITING MESSAGE WILL BE DISPLAYED.  
Refer to paragraph 10.2.3 to change the 60 sec. heating time.  
Before insert the probe in working area, agitate it for same seconds in fresh and uncontaminated air. Press the [ZERO]  
key to reset the measure and start CH4 monitoring.  
From this moment the unit will compare the correct CH4 reading. Pressing the [X] key you can change the probe range  
to 500ppm/box. Pressing the [W] key you can return to 100ppm/box range.  
Eclipse suggest to use 100ppm/box for ambient gas checking and 500ppm/box for pipe gas leak testing.  
After zeroing, the boxes will fill proportionally with the reading and an intermittent sound advise the operator for gas  
concentration as shown in the following table:  
1 box = 1 beep/sec  
2 box = 2 beeps /sec  
3 box = 3 beeps /sec  
4 box = 5 beeps /sec  
5 box = continuous beep  
Press [ESCAPE] (F2) to return to the previous menu.  
7.12  
Temperature & Humidity probe (option)  
To enable temperature and relative humidity monitoring press the [MENU] key from measuring page. The following page  
will be displayed:  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
AMBIENT ANALYSIS  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “MEASURE” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
MEASURE  
P DECAY LEAK TEST  
GAS LEAK TEST  
AMBIENT CO  
ENVIRON. TEMP/HUM  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “ENVIRON. TEMP/HUM” option.  
Press the [ENTER] key to select the option. Press [ESCAPE] (F2) to return to the previous menu.  
Connect the probe to the unit and wait for the following page:  
ENVIRON. TEMP/HUM  
Tamb : 25.7 °C  
Rel. Hum.: 50.2 %  
ESCAPE  
NOTE: WHEN PROBE IS CONNECTED THE INSTRUMENT BEGIN A 40 SECONDS WAITING TIME. IF PROBE IS CONNECTED IN  
“ENVIRON. TEMP/HUM” PAGE, A WAITING MESSAGE WILL BE DISPLAYED.  
Press [ESCAPE] (F2) to return to the previous menu.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
8
MEMORY MANAGEMENT  
The standard configuration include an internal memory to store up to 250 complete gas analysis divided by Tags (max.  
40 tags). Each analysis includes 10 gas concentration values, data and time. Each Tag includes one or more analysis  
data, 16 characters ID, 3 rows for the Customer data, Draught and smoke index values, Water temperatures, etc.  
An optional PC compatible PCMCIA internal adapter can be installed for memory extension.  
Press the [STORE] key to store, delete and assign the Tag for the current analysis. The following option will be  
displayed:  
STORE  
TAG SELECTION  
DELETE MEMORY  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to select the option.  
NOTE:  
BEFORE STORE OR DELETE THE MEMORY YOU MUST SELECT THE TAG IF IT IS DIFFERENT FROM THE CURRENT.  
8.1  
Store data analysis  
If you had pressed the [ENTER] key with the cursor on the “STORE” option, the analyzer will display the following  
message:  
WAIT … storing in process  
The analysis data will be memory stored in the current Tag and you can display or print all data when you need it.  
8.2  
Delete memory  
If you had pressed the [ENTER] key with the cursor on the “DELETE MEMORY” option, the analyzer will display the  
following message:  
!! ATTENTION !! The memory will be deleted when you press [DELETE]  
If you press the [DELETE] key (F1), The analysis data will be deleted.  
8.3  
Recall memory  
When you have stored the analysis data, you can recall the measured values by pressing the [MENU] key. The following  
page will be displayed:  
MENU  
MEASURE  
RECALL MEMORY  
FLOW/RETURN TEMP  
AMBIENT ANALYSIS  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to “RECALL MEMORY” option.  
Press the [ENTER] key to select the option.  
Press [ESCAPE] (F1) to return to the previous menu.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
RECALL MEMORY  
TAG SELECTION  
MEMORY DATE  
MODE  
VIS.MEM  
ESCAPE  
NOTE:  
BEFORE RECALL THE MEMORY YOU MUST SELECT THE TAG IF IT IS DIFFERENT FROM THE CURRENT,  
SELECT THE READING MODE: SINGLE OR AVERAGE AND SELECT THE STORED DATA.  
Press [VIS.MEM] (F1) to visualize the analysis data: the selected memory data or the average values of the selected  
Tag. Press [PRINT] (F2) to print the report for the displayed data.  
To change the recalling mode follow the procedure below:  
Use the [S] and [T] keys to move the cursor symbol to “MODE” option.  
Press the [ENTER] key to select the option.  
Use the [S] and [T] keys to move the cursor symbol to “Single” or “Average” mode.  
Press the [ENTER] key to select the option.  
Press [ESCAPE] (F1) to return to the previous menu without save the selection.  
To change the memory date follow the procedure below:  
Use the [S] and [T] keys to move the cursor symbol to “MEMORY DATE” option.  
Press the [ENTER] key to select the option.  
Use the [W] and [X] keys to display the date/time for all current Tag memory.  
Press the [ENTER] key to select the option.  
Press [ESCAPE] (F1) to return to the previous menu without save the selection.  
8.4  
DBGas 2000  
DBGas 2000 is a PC Windows 95/98/NT compatible program to manage all checks and measures activities on boilers  
and to transfer data from and to Eclipse Gas analyzers. The software is designed for a complete and efficient managing  
and recording of the analysis data of your clients. DBGas 2000 allows you to have a no limits database on your PC with  
all customer and boiler information, to select up to 40 boiler to be check, to assign an operator name and transfer the  
data to the analyzer. The operator will memory store up to 250 boiler checks and print the report; after the analysis he  
can transfer the data to the PC. The software will assign the analysis to the correct boiler in the database. Operator can  
view and print the data until he delete these.  
The main menu is made by 4 buttons: Plants/Clients, Analysis, Fuels and Exit from program.  
8.4.1  
Plants/Clients menu  
Selecting this option, you can manage the customers, boilers and plants information database and it is possible to  
transfer this data from the PC to the analyzer. For each plant can be assigned the customer personal data (name,  
address, phone and fax numbers, etc.) and one or more boiler information (name, type, fuel, etc.).  
Database is organized as a two separate tables: Plants/Clients database and Boilers installed.  
Selecting one plants on the upper table, the lower table will show you the boilers installed on that plant.  
All data can be changed easily by made a click with the mouse pointer on the cell. You can input the new data on the  
blank row (the last one) for adding a new boiler or new plant record. To delete a boiler or a plant you have to select it with  
a click and press the “Delete” key on PC keyboard.  
To have a more readable database, you can reduce, enlarge or hide the columns; approach the mouse pointer to the  
right limit of the cell to be reduce (enlarged), pressing the right button move the mouse to the left (right). By pressing two  
time quickly the left mouse button on the column, this will be automatically adapted to the pre-set dimensions. All  
changes will be saved when you exit from the program.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
When database is complete, you can select up to 40 boilers on the table for data transfer by selecting the “Select for data  
transfer” column. Pressing the “Select to Do Analysis”, you can select in automatic mode all analysis made by more than  
“XX” months.  
Pressing the “Show selected” button, the program will show all boiler selected for data transfer.  
You can exclude manually one or more boiler from the list. Select or input the operator name, connect the IR to RS232  
adopter to the PC, approach the IR terminal to the analyzer IR communication windows, and press the “Send” button to  
send the data to the analyzer.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
8.4.2  
Analysis menu  
This option is the main part of the program. You can transfer the analysis data from the analyzer to the PC, save and  
manage it using a database structure, display and export the data in Microsoft ExcelTM compatible format.  
The analysis window is made by 3 tables: plant and customer information, boiler information for the selected plant and  
analysis groups data for the selected boiler.  
The analysis groups data will be ordered by data and will show the general data for the group of measurements (smoke  
indexes, T flow and return, etc.).  
Select by mouse the Plant, Boiler and Group to be displayed. The arrows on the left column on the tables will show you  
the current record. Pressing the View measure” button you can read the single data measurements for the selected  
group (contents of gas, temperatures, pressure/draught, efficiency, smoke index, etc).  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
The operator can change the measuring units, the fuel type, etc. The program will made the conversion in real time and  
will display the new values.  
A set of 4 buttons allows you to set the printer, to print measures, export measures using an Excel compatible format,  
show or hide the columns.  
A fifth button is normally disabled and it allows to display graphics. To display graph, you have to select one or more  
columns for graphics. Select the column by positioning the mouse pointer on the desired column header and click, using  
the mouse left button; click using the mouse right button and select the “Select for graph” option. The column header will  
be displayed in Italic. The “Show graph” button became active. You can display the graph by pressing the “Show graph”  
button.  
Activate the cursor and snap cursor to the desired parameter. Using the mouse you can move the cursor amongst the  
measure.  
8.4.3  
Fuels menu  
You can read from the analyzer all data parameters for the stored fuels. Press the “read from instrument” button to  
transfer, using the IR interface, the fuel data from the analyzer.  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
NOTE:  
THE FUEL DATA TRANSFER FROM ANALYZER SHOULD BE MADE AFTER THE PROGRAM INSTALLATION OR IF THE FUEL DATA  
CHANGES ON THE ANALYZER.  
IMPORTANT  
TO CHANGE OR ADD NEW FUELS DATA, YOU HAVE TO USE GASCONFIG SOFTWARE. THE INSTRUCTIONS ARE SHOWN ON 9.2  
PARAGRAPH.  
8.4.4  
DBGas 2000 Installation  
DBGas 2000 runs on IBM PC under WINDOWS 95/98/NT. Minimum requirements are a Pentium CPU with 16Mbyte  
Ram and 20 Mbyte on hard disk, a color monitor and a Microsoft mouse or a compatible one.  
In order to install DBGas 2000 for Windows, follow the below procedure:  
Place the DBGas 2000 disk in a CD-ROM drive;  
From the Windows Start Menu, select <RUN>;  
Enter the filename D:SETUP.EXE (substitute the letter D for the disk drive that contains DBGas 2000 disk)  
Follow the on screen instructions making sure to provide the correct path to your DBGas 2000 directory when  
prompted.  
Once installed, the DBGas 2000 icon will appear on your Windows screen and it will be possible to boot it by clicking on  
the icon as usual.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
8.5  
Configuration Software  
GasConfig software is a PC windows compatible program for configuring the EGA4 flue gas analyzers. You can change  
all memory settings: displayed measurements pages, printed measurements layout, Alarms, Fuels coefficients,  
measuring technical units, etc.  
8.5.1  
How operate using GasConfig  
When you run GasConfig a 2 independent windows system will be displayed on the PC monitor.  
The window on the left is a parameter icon list. This list show all possible parameters for measured (O2, CO, Tgas,  
Draught, etc.) and calculated measures (CO2, Efficiency, etc.). Same of these can be not available in your instrument (it  
depends by instrument model, installed cells, and options).  
The window on the right is the program user interface. It is organized in function pages; you can select the page for  
interesting parameters using the mouse.  
A main menu bar allows you to load and save the configuration data, to change communication setting, for data transfer  
from and to the analyzer.  
WARNING  
BEFORE CONFIGURATION DATA TRANSFER FROM AND TO YOUR PC, BE SURE TO HAVE SELECTED THE EGA4 UNIT USING THE  
“INSTRUMENT” OPTION ON MAIN MENU BAR.  
The available function pages are:  
General  
This page allows you to set the general parameters as engineering units, O2% reference  
values, etc.  
Pages  
You can set up to 6 different pages in your instrument to display up to 36 different  
measured and calculated values.  
Printer  
You can program the complete layout for report printing: header, measured parameters,  
etc.  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Alarms  
You can enable, disable, and program up to 4 different acoustic and visible alarms for  
critical measurements.  
Aux Inputs  
Analog Output  
Timer  
Fuels  
Bar graphs  
Service  
Not available for software version 1.001  
Not available for software version 1.001  
You can change the autozero time and the leak decay time.  
Up to 10 different fuels coefficient tables can be programmed.  
You can set up to 6 different bargraph (parameter and range).  
3 services information lines can be programmed for factory co-ordinates. (We suggest to  
have Eclipse telephone and fax numbers).  
8.5.2  
GasConfig Installation  
Software runs on IBM PC under WINDOWS 95/98/NT operative systems. Minimum requirements are a Pentium CPU  
with 16Mbyte Ram and 8 Mbytes on hard disk, a color monitor and a Microsoft mouse or a compatible one.  
In order to install the Software for Windows, follow the below procedure:  
Place the Software disk in a CD-ROM drive;  
From the Windows Start Menu, select <RUN>;  
Enter the filename D:SETUP.EXE (substitute the letter D for the disk drive that contains Software disk)  
Follow the on screen instructions making sure to provide the correct path to your Software directory when prompted.  
Once installed, the EGA4 Configuration Software icon will appear on your Windows screen and it will be possible to  
boot it by clicking on the icon as usual.  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
9
CONFIGURATION  
Many parameters can be modified using the instrument keyboard. Pressing the [SETUP] key, you can change the  
current fuel, include or exclude the CO cell, change the technical unit, set the alarms, etc. The  
CONFIGURATION  
P1  
--- FUEL ---  
> LPG  
CO SENS. Includ.  
FUEL PARAMETER  
NEXT  
ESCAPE  
press [NEXT] to change menu page  
CONFIGURATION  
P2  
ENGENEERING UNITS  
ALARMS  
%O2 REFERENCEs  
NEXT  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to select the option.  
Press [ESCAPE] (F1) to return to the previous menu.  
Fuel  
You can select between the pre-set fuel table (LPG, Diesel oil, Oil, Natural gas) or, if  
programmed using the configuration PC software, 6 customizable.  
If the CO electro-valve option is installed, you can Include, exclude or automatically select  
(using the PC configuration software, you can program the CO level for automatic exclusion)  
the CO cell.  
CO cell  
Fuel Parameters  
You can display only all the constant table for the selected fuel. To change the values, you  
should use the configuration PC software.  
Engineering Unit  
Alarms  
You can change the technical units for gas, temperature and pressure measurements.  
You can set the alarms levels, Min/Max operation and enable/disable all the 4 possible  
acoustic and visible alarms.  
%O2 references  
You can set the %O2 for CO measurements and %O2 for other gas.  
9.1  
Engineering Units  
When you select the Engineering unit option, the following page will be displayed:  
MEASURING UNITS  
> CO  
Other  
Temp.  
Press.  
ppm  
ppm  
°C  
mmH2O  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to change the value.  
Press [ESCAPE] (F1) to return to the previous menu.  
The measuring units selectable for gas are: ppm, mg/m3, mg/kWh, g/GJ.  
The measuring units selectable for temperature are: °C, °F.  
The measuring units selectable for pressure are: hPa, mbar, mmH2O, inH2O.  
9.2  
Alarms  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
When you select the Alarms option, the following page will be displayed:  
ALARMS  
Alarm  
1: O2  
Enabled  
Thresh.  
Type  
:
Yes  
: 5.00  
:
Min  
NEXT  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to change the value.  
Press [ESCAPE] (F1) to return to the previous menu.  
Press [NEXT] (F1) to display the next alarm page. Up to 4 alarms can be set for different gas type and levels.  
NOTE:  
THE REFERENCE GAS FOR ALARMS ARE PROGRAMMED IN FACTORY. THE GAS TYPE CAN BE CHANGED ONLY USING THE  
OPTIONAL PC CONFIGURATION SOFTWARE.  
When the measured value became in alarm band, a continuous sound (beep) inform you the condition. Simultaneously,  
the parameter will be displayed in the measuring page in reverse mode. You can acknowledge the alarms pressing the  
[ENTER] key. In this case the beep will stop but the reverse mode remain.  
9.3  
HELP key  
Help menu inform of the instrument status (electrochemical cells status and battery level), Service information and allows  
you to change the header printer text.  
When you select this option, the following page will be displayed:  
HELP  
HEADER PRINTER  
SENSOR DIAGNOSTIC  
Batt. 100%  
SERVICE  
ESCAPE  
Press [ESCAPE] (F2) to return to the previous page.  
9.3.1  
Header setting  
The “HEADER PRINTER” option, allows you to set 4 rows of 16 characters for report header printing.  
Press the [ENTER] key when the cursor symbol is positioned near the menu option. The following page will be displayed:  
HEADER PRINTER  
R1  
R2  
R3  
R4  
ESCAPE  
Select the R1, R2, R3, and R4 rows and press [ENTER] to insert or change the text.  
Press [ESCAPE] (F2) to return to the previous page.  
9.3.2  
Sensor Diagnostic  
The “SENSOR DIAGNOSTIC” option, allows you to read the actual status for the inserted cells.  
Press the [ENTER] key when the cursor symbol is positioned near the menu option. The following page will be displayed:  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
SENSOR DIAGNOSTIC  
428.46 uA  
O2  
CO  
NO  
0.34 uA  
1.09 uA  
ESCAPE  
Press [ESCAPE] (F2) to return to the previous page.  
9.3.3  
Service Data  
The “SERVICE” option, allows you to read the information to contact us for service assistance and the information that  
we wont to know for identify your instrument configurations: instrument configuration code and serial number, firmware  
version, etc.  
Press the [SERVICE] (F1) to display the following page:  
Eurotron Srl  
Tel. 022488201  
Fax 022440286  
Mod UniGas 3000  
Cod F7823-1-x-0-  
SN:  
26024 V: 1.001  
ESCAPE  
Press [ESCAPE] (F2) to return to the previous page.  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
10  
MAINTENANCE  
The EGA4 analyzer has been developed and manufactured using high quality components. A correct, systematic  
maintenance will prevent damage and will increase substantially the life of the instrument, giving excellent results.  
Anomalous conditions that require extraordinary maintenance interventions are promptly displayed, either clearly or with  
an information code.  
10.1  
Error messages  
The instrument performs the autodiagnostic procedure when switched on. When measuring it checks also for  
anomalous conditions. If analyzer founds trouble, it display a message on LCD. Sometime these messages corresponds  
to a unrecoverable problem and it is necessary to return the instrument to Eclipse for maintenance. Frequently these  
message are referred to a recoverable trouble and can be solved by yourself.  
The following table show the possible instrument error messages:  
Error message  
Problem  
Solutions  
Calc Err  
Parameter calculus error.  
The instrument cannot perform the  
calculus. Check and solve the others error  
conditions.  
Probe Er  
RJ Err  
Over  
The  
external  
Rtd  
probe  
is Connect  
or  
replace  
the  
external  
unconnected or damaged.  
temperature probe.  
Internal  
damaged.  
temperature  
reference Return the instrument to Eclipse for  
maintenance  
Overrange condition  
Underrange condition  
No calculus available  
The problem is solved automatically when  
measure return inside the range  
Under  
The problem is solved automatically when  
measure return inside the range  
--------  
The instrument cannot perform the  
calculus. Check and solve the others error  
conditions. (e.g. O2>18%).  
CO sensor excluded by electro-valve Automatic CO sensor protection is active.  
Perform one or more autozero cycle in  
fresh air.  
Excluded  
Tc Error  
The thermocouple is unconnected or Connect or replace the temperature probe.  
damaged.  
Tsens Er  
Cell compensation error  
Return the instrument to Eclipse for  
maintenance.  
Perform one or more autozero cycle in  
fresh air. If the problem remain, Return the  
instrument to Eclipse for maintenance.  
Zero Err  
Sens. Er  
The autozero procedure is failed  
Broken cell  
Return the instrument to Eclipse for  
maintenance.  
No meas.  
No sens.  
No probe  
Empty Memory  
The cell is non installed  
No external probe connected on Connect or replace the temperature probe.  
mini-din connector.  
10.2  
Set-up menu  
Configuration menu is protected by a password. This procedure menu allows the operator to change some internal  
parameters values: Date and time internal clock, communication baud rate, autozero time and leak test timing.  
Follow the procedure below to activate the procedure:  
Switch the instrument off  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
Press and maintain the [SETUP] key down; press the [ON/OFF] key.  
The analyzer will switch on. A password input page will displayed. Insert the password code “0011” and press the  
[ENTER] key. The following page will displayed:  
SET-UP  
Pag.1  
CLOCK  
SERIAL PORT  
ANALYSIS PAR.  
P DECAY TIME  
ESCAPE  
NEXT  
Press the [NEXT] (F1) key to change menu page.  
SET-UP  
Pag.2  
PRINTER TEST  
CLOCK TEST  
ESCAPE  
NEXT  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to enter in the option set-up page.  
Switch the instrument off to exit from the configuration procedure  
10.2.1  
Clock  
Select this option for date and time set-up. Verify that the current values are corrects because the analyzer use these  
data for analysis storing.  
CLOCK  
Hour  
Minutes  
: 10  
: 22  
DATE  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to enter in the option set-up page.  
Press [ESCAPE] (F2) to return to the previous menu.  
Press [DATE] (F1) to change date.  
DATE  
Day  
: 10  
Month  
Year  
Type  
: 22  
: 1999  
: EURO  
TIME  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to set a new date or date format (European or USA).  
Press [ESCAPE] (F2) to return to the previous menu.  
Press [TIME] (F1) to change time.  
10.2.2  
Serial Port  
Selecting this option, you can set the baud rate and the ID number for instrument in infrared serial communication.  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
SERIAL  
Address  
Baud-rate  
: 0  
: 9600  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to set a new ID number or baud rate.  
Press [ESCAPE] (F2) to return to the previous menu.  
10.2.3  
Analysis  
Selecting this option you can change the analyzer auto-zeroing time and CH4 & Natural gas heating probe time (we  
suggest to use the pre-set values of 180 sec for autozero time and 60 sec for CH4 heating time).  
ANALYSIS  
AutoZ. Time  
: 180  
CH4 Heat. Time: 60  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired option.  
Press the [ENTER] key to set a new Auto-zero time.  
Press [ESCAPE] (F2) to return to the previous menu.  
10.2.4  
Leak test time  
Selecting this option, you can change the timing for leak test using the decay method. The test has a total period of 310  
seconds and the programmable time represent the interval between the measurements.  
P DECAY TIME  
Time P1 : 10  
Time P2 : 60  
Time P3 : 120  
Time P4 : 120  
ESCAPE  
Use the [S] and [T] keys to move the cursor symbol to the desired interval.  
Press the [ENTER] key to set new acquisition intervals.  
Press [ESCAPE] (F2) to return to the previous menu.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
10.3  
Firmware Upgrade  
In order to upgrade the firmware of the instrument proceed as follows:  
1 - Install the ST167Flash program from the CD.  
2 - Connect the infrared interface adapter to the serial port of the PC with the supplied cable (note back the serial port  
used: COM1 , COM2 or other).  
3 - Position the interface near the right side of the instrument.  
4 - Run the ST167Flash program you have installed.  
5 - Select the same serial port that you noted back.  
6 - Select the Baud rate to 115200 Baud (if the PC owns an UART 16550 type), otherwise select a lower Baud rate.  
7 - Press the three dotted button in order to load the firmware file (.HFW extension) normally located on a 3 1/2" diskette.  
A version number of the firmware being discarded is shown in the dedicated field.  
8 - From instrument OFF press and continue to press the F1 key while pressing the ON/OFF key in order to set the  
instrument in firmware upgrade status.  
9 - Click on the 'Program' button to start the upgrading phase and wait until a termination message appears.  
NOTE: IF DATA TRANSFER FAILS, PLEASE TURN OFF THE INSTRUMENT AND REPEAT THE PROCEDURE FROM STEP 8.  
10.4  
Smoke pump maintenance  
Gas-tight checking  
To have a correct measurement the pump should be gas-tight. Turn the screw and close the probe with your finger. Pull  
the plunger for 3 cm and verify that the gasket does not leak the vacuum. If a leak is found the gasket needs to be  
lubricated. When you push the plunger the valve must close immediately to have a 1.9/2.0 litres of air with 10 shoots.  
The correct smoke index can be obtained only if the pump works correctly.  
Service  
1. Clean and lubricate the cylinder, the stem and the gasket every 30 measurements.  
2. Wash using alcohol if the valve is not gas-tight  
3. Clean the probe and the paper support  
4. Check the pump for gas-tight  
5. Use only clean paper filters and a readable scale index table  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
11  
CERTIFICATES  
11.1  
Warranty terms  
Each instrument is shipped with a Warranty Certificate that indicates the validity conditions of the warranty itself. Eclipse  
warrants its products against defects in materials and workmanship.  
If the unit should malfunction, it must be returned during the warranty period, transportation prepaid, to Eclipse for  
evaluation. Upon examination, if the unit is found to be defective it will be repaired or replaced at no charge.  
Eclipse‘s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to  
mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This  
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as  
a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or  
other operating conditions outside of Eclipse‘s control.  
This warranty applies to the original purchaser only. Please include a copy of the original invoice or a small service  
charge may be applied.  
Direct all warranty and repair requests/inquiries to the Eclipse Customer Service Department. BEFORE RETURNING  
ANY PRODUCT(S) TO ECLIPSE, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM  
ECLIPSE‘S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS).  
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in  
transit.  
11.2  
Letter of conformity  
Each instrument is shipped with a Letter of Conformity, to grant that the characteristics of the instrument correspond to  
the required ones, and that the instrument calibration is traceable to the National and International Standards.  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
APPENDIX  
A1  
Example  
The following steps show how you can make a quick measurement using the EGA4 portable analyzer.  
1. Switch EGA4 on. It will begin the autozero and the autodiagnostic procedure. System error and trouble will be  
displayed if encountered.  
EcoLine 4000  
Serial Num:  
Version  
!
! probe in chimney  
Don t insert  
!
!
1257  
1.001  
:
Op.: Antonio  
Bat: 5.2V (23.5°C)  
Autozero: 180 sec  
MEASURE  
MENU  
2. Select the combustible used by burner. It is possible choosing between 4 preset and other 6 customizable types.  
! Now insert  
! probe in chimney  
!
!
--- FUEL --  
Natural Gas  
TAG SELECTION  
ANALYS.  
3. Connect the sampling probe electrical and pneumatic terminals to the EGA4.  
4. Insert the sampling probe in chimney. Be sure for mechanical positioning and flue gas intercepting.  
5. Press ANALYSIS] (F1) key to start the measurements. Select the desired data page using [] and [] keys. Zoom  
in or out to enlarge or reduce the visualized characters using the [X] and [W] keys.  
O2  
Ta  
Tf 400.3C : NO2  
95.7%  
CO2 10.2p :  
NOx 500p :  
20.9% : CO  
20.2C : Eff 0.99  
100p  
2000p  
O2  
CO2  
CO  
20.9%  
0.0%  
1ppm  
η
:
Ref O2  
Ref O2  
6. Finishing measurement procedure, press the [PRINT] key to print one or more reports.  
PRINT  
MEASURE HOLD  
PRESS [PRINT]  
NO. COPY  
MODEL  
1
Standard  
FEED  
ESCAPE  
7. Dismount the system and switch it off. All system can be put back in a rugged and practical case.  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Instruction Manual MM850481 ed.01  
INDEX  
Gas sensors; 12  
GENERAL; 8  
GENERAL DESCRIPTION; 5  
A
Accuracies and ranges; 7  
Alarms; 40  
Ambient CO probe; 29  
Ambient CO probe; 6; 9  
Ambient T+RH probe; 6  
Analysis; 45  
H
Header setting; 41  
HELP key; 41  
How operate using ConfiGas; 38  
Analysis data print; 25; 26  
Analysis menu; 35  
APPENDIX; 48  
I
Input of the smoke index; 24  
Auxiliary measure; 13  
K
B
C
Keyboard; 18  
Keypad; 8  
Barcode pen reader; 9  
Basic operation; 18  
Built-in printer; 8  
L
Burner pressure probe; 9  
Leak test time; 45  
Leakage checking mode; 9  
Leakage limits table; 28  
Letter of conformity; 47  
line filter; 12  
Calibration certificate; 9  
CERTIFICATES; 47  
change page; 19  
Clock; 44  
CO probe operations; 29  
M
Combustion air temperature; 24  
ConfiGas Installation; 39  
CONFIGURATION; 40  
Configuration Software; 38  
CONNECTIONS; 16  
Maintenance; 46  
MAINTENANCE; 43  
Measurement principle; 11  
Measuring cells; 8  
Measuring instruments; 14  
Measuring Units; 40  
Contrast; 19  
MEMORY MANAGEMENT; 32  
D
N
DBGas 2000; 33  
DBGas 2000 Installation; 37  
Delete memory; 32  
Display; 8; 18  
Natural gas probe; 9  
Numeric input; 19  
Display regulation; 19  
O
E
OPERATIONS; 18  
Other measurements; 14  
Electro-pneumatic connections; 16  
Error messages; 43  
P
Esempio di misura; 48  
Paper and Ribbon change; 26  
PHYSICAL DESCRIPTION; 10  
Plants/Clients menu; 33  
F
Features and Benefits; 5  
Firmware Upgrade; 46  
Flow/Return temperature; 24  
Fuel technical data; 8  
Fuels menu; 36  
Power supply; 15  
Pressure and Draught; 13  
Pressure decay procedure; 27  
Pressure sensor; 8  
Pressure/Draught measurement; 22  
PRINCIPLE OF OPERATION; 11  
G
R
Gas analysis; 21  
Gas leak cheker; 30  
Gas probe positioning; 16  
Gas sampling probe; 8; 11  
Recall memory; 32  
RECOMMENDATIONS; 15  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Instruction Manual MM850481 ed.01  
Remote temperature probe; 9  
T
T+RH% probe; 9  
S
Temperature & Humidity probe; 30  
Temperature measurements; 13  
Temperature probes; 8  
Select by a list; 20  
Sensor Diagnostic; 41  
Serial Port; 44  
Text input; 20  
Service Data; 42  
Set-up menu; 43  
W
Smoke index measurement; 13  
Smoke measurement; 9; 23  
Specifications; 6  
Warranty terms; 47  
Water trap; 12  
status bar; 19  
Store data analysis; 32  
Z
ZOOM function; 19  
924-2 Instruction Manual 11/1/03  
Litho in USA  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Educational Insights Telescope EI 5237 User Manual
Etymotic Research Headphones Ety8 User Manual
Fellowes Paper Shredder CC4 User Manual
Fisher Price Model Vehicle N0246 User Manual
Frigidaire Dishwasher 740 Series User Manual
Furuno Radar Detector 1823C User Manual
GE Computer Drive PDW8100 User Manual
GE Power Supply LP11U User Manual
Gianni Industries Switch CP 24G User Manual
Goodman Mfg Heat Pump SSZ 14 SEER User Manual