MODEL: PS-PRO HT
Home Theater Pro Level AC Power
Conditioner/Sequencer
Featuring 3-Channel Sequencing, 20 Amp Capac-
ity, Over Voltage Shutdown, and Programmable
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
ing, and potentially destructive “pop” reaching
the speakers.
go on immediately, Delay 2 outlets will receive
power 15 seconds after Delay 1 outlets, and
Delay 3 outlets will receive power 15 seconds
after Delay 2 outlets. Therefore the total delay
time is 30 seconds.
In any large system whose components present
an inductive load to theAC line (including electric
motors, power supplies, and power amplifiers
of all kinds), sequenced powering can avoid
excessive inrush currents that can cause circuit
breakers to trip even though the steady-state
currents are not excessive. Power sequencing
is particularly suited to applications where large
installations must be switched by inexperienced
personnel.
The order is reversed on an OFF sequence. For
example, when an OFF sequence is initiated and
the Delay Adjust control is set at 60 seconds,
Delay 3 outlets lose power immediately, Delay 2
outlets lose power 30 seconds later and Delay 1
outlets lose power 30 seconds after the Delay 2
outlets have been shut off. The total delay time
is 60 seconds.
The PS-PRO HT is controlled by a front panel
key-operated switch to provide security from
non-authorized users tampering with the system.
The switch has three positions: OFF, REM, and
ON, allowing for local or remote control. With
remote control, one or more PS-PRO HT’s may
be installed in remote locations with on/off con-
trol and LED monitoring via low-voltage control
wires. The PS-PRO HT interfaces with computer
touch screen systems as well.
In the event of a power out, of course all equip-
ment plugged into a PS-PRO HT will lose power
simultaneously. However, when power is re-
stored, the delayed outlet groups will again turn
on in the usual delayed sequence (Remains off
in Momentary Mode).
Installation Recommendations: In home theater
installations, we recommend that power amps or
receivers be powered last — plug them all into
Delay 3 or divide them into two groups and plug
one group through Delay 2 and the other through
Delay 3. Low level equipment such as video and
audio processors should use Delay 1. Equipment
incorporating clocks or timers such as VCR’s, or
equipment that must respond to wireless remote
actuation, should use the unswitched outlets.
We suggest keeping the front panel unswitched
outlet free for equipment that is only in use
temporarily.
Besides its power sequencing capabilities, the
PS-PRO HT contains many other conditioning
and protection features. Both aspects of its func-
tioning will be discussed in the next sections.
The PS-PRO HT rear panel provides one un-
switched outlet pair and three switched outlet
pairs. The switched outlet pairs are labeled
Delay 1, Delay 2, and Delay 3. (The other pair of
outlets on the rear panel and an additional single
outlet on the front panel are unswitched.)
Here’s how the PS-PRO HT works: When an
ON sequence is initiated, power is immediately
applied to the Delay 1 outlets. Power is then
applied to Delay 2 and Delay 3 outlets per the
1-60 second total delay setting you choose with
the front panel Delay Adjust control.
The overall capacity of the PS-PRO HT is 20
amps. This refers to the combined steady-state
current drawn by all devices plugged into all of
its nine outlets. If this combined current level
exceeds 20 amps at any time, the circuit breaker
will trip, cutting off power to your rack. If this oc-
curs, you must reduce the load by unplugging
one or more units from the PS-PRO HT. Then
push the white button on the circuit breaker (on
The screwdriver-settable Delay Adjust controls
the total delay time between the Delay 2 and
Delay 3 outlets. For example, if the DelayAdjust
control is set to 30 seconds, Delay 1 outlets will
2
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
the front panel) in to reset it.
tions, if the voltage falls below 80 volts or rises
above 140 volts. This feature is called “Extreme
Voltage Shutdown.” See pages 5-6 for more
information on the various protection features’
indicator lights.
Although 20 amps is an absolute limit, the
PS-PRO HT will allow you to come as close
as possible to using the full 20 amps, because
with power sequencing, the risk of tripping the
breaker is greatly reduced. This is because the
PS-PRO HT handles large but temporary inrush
currents in stages, rather than simultaneously,
allowing each stage to settle to its steady-state
current draw before the next stage is powered.
Despite its many protective features, you should
be aware that the PS-PRO HT does not compensate
if the AC line voltage itself is high or low (i.e., it
does not compensate for brownout conditions). If
you are in an area particularly prone to brownouts,
you may benefit from the use of one of Furman’s
Reference AC Line Voltage Regulators in addition
to the PS-PRO HT. If you do use a voltage regula-
tor, run the raw power line into the regulator first
so that the PS-PRO HT receives a stabilized voltage
to distribute.
Outlets and Plugs: The PS-PRO HT’s four
rear panel outlet pairs are standard 120V, 20A
duplex types. These outlets are widely spaced,
to accommodate one bulky plug-mounted “wall
wart” power supply in each without covering up
an adjacent outlet. The front panel outlet is lim-
ited to 15 amp use. The PS-PRO HT also uses
a 20 amp line cord, which can be recognized by
the perpendicular blades on the plug. In 20 amp
products, use of a plug of this type is required for
UL safety certification. It is compatible with 20
amp outlets (such as the ones on the PS-PRO
HT’s rear panel.)
ON OR OFF SEQUENCING
The method of initiating an ON or OFF sequence
depends on whether the unit is to be controlled
locally or remotely. If remotely, it further depends
on the type of switch or switches used (momentary
or maintained).
Local Control: For local control, an ON sequence
is initiated by turning the key switch to the ON
position, and an OFF sequence by turning the key
switch to REM or OFF position.
POWER CONDITIONING FEATURES
The PS-PRO HT provides a very high degree of
power conditioning protection for your expensive
and delicate equipment. What sets Furman’s
PRO-level protection apart from that offered by
other conditioners is the quantity, quality, and
configuration of its suppression devices. These
include MOV’s, gas discharge tubes, fast-blow
fuses, and high voltage capacitors. This unique
combination can safely absorb and dissipate
large spikes from nearby lightning strikes and
other sources (up to 13,000 amps), as well as
highly attenuate audible high frequency noise.
Clean, filtered power is provided at all 9 outlets,
even the unswitched ones.
Remote Control: When the PS-PRO HT’s front
panel key lock switch is in the REM position, it
may be controlled by one or more switches in
remote locations. In the most basic configuration,
only two wires and an SPST switch are needed to
initiate an ON or OFF sequence. The switch may be
either a momentary or a maintained-contact type,
depending on a jumper setting inside the PS-PRO
HT. If an additional wire is used, an LED may also
NOTE: If the PS-PRO HT is to be used under local
be installed at the remote end to indicate that the
control only, and a jumper is installed on JMP1,
power is on.
and no switch is connected to the PS-PRO HT’s
Momentary vs. Maintained Contact
terminal strip, then a jumper should be connected
The PS-PRO HT will even keep itself from turn-
ing on, or will shut down under extreme condi-
between the REM and +12V terminals. Otherwise,
Switching
turning the front panel key switch to the REM
An on-off switch of either kind may be used to
3
actuate the PS-PRO HT’s remote operation.
Maintained switches, such as most toggle
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
switches and push-on/push-off button switches,
(including the Furman RS-1 key lock switch),
stay open until switched, and then remain closed
until switched again. Momentary switches,
usually push-button types like the Furman RS-2
(which also provides a locking key switch), are
normally open and stay closed only as long as
the button is pressed.
Maintained switches are generally most
convenient when there is only one remote
location.Whenmorethanonelocationisrequired,
momentary switches offer the advantage of
a turn-on or turn-off sequence which may be
started from any location.
Maintained Mode
There are 3 maintained modes of operation:
For integrating the PS-PRO HT into computer
control/touch screen systems use “momentary
mode.”
REM to +12V = OFF (jumper plug installed on
JMP1, MAINT ON)
The connection of the REM terminal to the +12V
terminal initiates an OFF sequence. Use this
The PS-PRO HT main circuit board has 5 pairs
of terminals labeled as:
JMP1 (MAINT ON), when the REM and +12V
terminals are tied together, the PS-PRO will
sequence OFF.
JMP2 (MOMENTARY), when the REM and +12V
terminals are momentary tied together, the PS-
PRO will sequence ON or OFF.
conductor and a double-throw switch.
JMP3 (MAINT OFF), when the REM and +12V
terminals are tied together, the PS-PRO will
sequence ON.
JMP4 (REM TO GND = ON), when the REM and
GND terminals are tied together, the PS-PRO
HT will sequence ON (Note: JMP1 must have a
jumper installed).
REM to +12V = ON (jumper plug installed on
JMP3, MAINT OFF) Defaut Setting
JMP5 spare jumper holder.
The connection of the REM terminal to the +12V
terminalinitiatesanONsequence. Disconnecting
initiates an OFF sequence. If the cable run is
long, it is recommended that the REM wire be
tied to the PS-PRO HT’s GND terminal during
OFF operation rather than leaving it floating.
PS-PROHTunitscomefactory-setformaintained
operation (jumper is installed on JMP3). They
may be easily converted to other operating
modes by moving jumper plug/plugs on the
PS-PRO HT’s circuit board. To do this, first
disconnect the unit from AC power. Remove
the four screws that secure the top cover and
one screw from the front panel. Just install the
jumper plugs to the desired mode of operation.
Reattach the top cover.
REM to GND = ON (jumper plugs installed on
JMP1 and JMP4)
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
FRONT PANEL
START ON/OFF SEQUENCE:This pushbutton switch
is used only when the key lock switch is in REM posi-
tion and the PS-PRO HT is in Momentary Mode. It
then acts the same as any other remote momentary
switch that may be connected to the rear panel ter-
minal strip. If the switched outlets are on, pushing
it begins an OFF sequence. If they are off, pushing
it begins an ON sequence. Do not use this switch
when in Maintained Mode.
PROTECTION OK: This LED is normally on when the
power to the PS-PRO HT’s outlets is switched on.
It monitors the integrity of the protection devices
and reports if the protection is compromised. If an
extremely large spike is encountered that exceeds
the PS-PRO HT’s capacity, the main group of input
protectors will blow an internal fuse, causing the
indicator to go out. If this LED is not lit when the
power switch is on, full protection is not function-
ing. Spike protection may still exist, but will have
a reduced capacity to absorb current. If this LED is
not lit, please contact the Furman Service Depart-
ment.
EXTREME VOLTAGE SHUTDOWN: This LED indica-
tor is normally off. It monitors a hazard common
in the entertainment industry—wiring faults—for
example, accidental connection to 220V. The PS-
PRO HT senses voltages that are so high or low
that operation would be impossible (under 80V
or over 140V) and shuts the power down before
damage can occur. Upon initially applying power
to the PS-PRO HT, this indicator will be lit if the
unit is receiving below 80 volts or more than 140
volts, and power will not be applied to the PS-PRO
HT’s outlets. If the unit has been operating with
an acceptable input voltage and then the voltage
goes out of the acceptable range, the PS-PRO HT
will shut down power to all of its switched outlets
simultaneously, without observing the OFF delay
5
cycle, and this LED will begin flashing. When power
returns to within the acceptable range, the PS-PRO
HT will observe its ON delays as it returns power to
its switched outlets, and this LED will go out.
NOTE: If the mains power is below 80 volts and
has caused the PS-PRO HT to remove power from
its outlets, the PS-PRO HT will not restore power
to its outlets until the mains voltage is more than
90 volts. If the mains power is above 140 volts and
has caused the PS-PRO HT to remove power from
its outlets, the PS-PRO HT will not restore power to
its outlets until the mains voltage is less than 130
volts. The reason for this is to prevent the power
oscillating on and off in marginal conditions.
DELAY ADJUST:This screwdriver-adjustable trimpot
allows you to set the total turn-on/turn-off delay
time from 1 to 60 seconds, as explained on page 4.
The trimpot adjusts both the on delay and off delay
times simultaneously.Turn the trimpot clockwise to
increase the on and off delay times; turn the trimpot
counterclockwise to decrease the delay times.
POWER STATUS (DELAY) LEDs: One green LED is pro-
vided for each of the three delay stages. Each LED
lights when power is applied to its corresponding
duplex outlet on the rear panel. All three LEDs then
remain steadily lit until power is removed. During
the power-down delay cycle, each LED goes off as
power to its corresponding outlet is removed. In
addition, the Delay 1 LED flashes if a remote switch
(or the stored state) is OFF.
UNSWITCHED OUTLET: This convenient outlet
provides power at all times when the PS-PRO HT
is plugged in and operating under normal power
conditions.
ON/REM/OFF SWITCH:When turned to the ON posi-
tion, this key lock switch initiates an ON sequence,
applying power to the PS-PRO HT’s switched out-
lets. When turned to the OFF position, it begins an
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
OFF sequence. In the REM position, the PS-PRO
HT will accept on/off commands from a remote
switch or switches that may be connected to the
rear panel terminals.
CIRCUIT BREAKER: The overall capacity of the PS-
PRO HT is 20 amps. If the combined steady-state
current drawn by all devices plugged into all of
its nine outlets level exceeds 20 amps at any time,
the circuit breaker will trip, cutting off power to
your rack. If this occurs, you must reduce the load
by unplugging one or more units from the PS-PRO
HT, and reset it. You can reset the circuit breaker by
simply pressing in the button, which pops out when
tripped. However, because it is a thermal type, you
may have to wait a few moments after it trips for it
to cool down before it will allow you to reset it.
UNSWITCHED OUTLETS: The PS-PRO HT rear panel
provides clean, filtered power to this pair of un-
switched outlets, adjacent to the power cord.
SWITCHED (DELAYED) OUTLETS: The PS-PRO HT
REAR PANEL
rear panel provides three pairs of switched outlets,
widely spaced to allow use of equipment with plug-
in (wall wart) transformers. These switched outlet
pairs are labeled Delay 1, Delay 2 and Delay 3. After
the front panel switch is thrown to ON, Delay 1
outlets receive power instantly, Delay 2 outlets re-
ceive power 1-30 seconds later and Delay 3 outlets
receive power 1-30 seconds after Delay 2 outlets
are powered. When thrown to OFF, the sequence is
reversed, with Delay 3 losing power instantly, Delay
2 outlets losing power 1-30 seconds later and Delay
1 outlets losing power 1-30 seconds after Delay
2 outlets are shut down. The delay intervals may
be altered with the screwdriver-adjustable Delay
Adjust control on the front panel.
indicate that the power is on.
TERMINAL STRIP: Allows one or more switches to be
connected to turn the PS-PRO HT on and off from a
remote location. Two, and sometimes three, wires
are needed to install a remote switch (see “Main-
tained Mode”, page 6.) If a four-conductor cable is
used, an LED may be installed at the remote end to
6
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
The connection of the REM terminal to the GND
terminalinitiatesanONsequence. Disconnecting
initiates an OFF sequence.
The front-panel key lock switch is not the primary
means of control in the momentary mode and
should normally be left in REM. It may be a useful
secondary means of control in the rare case of
having several PS-PRO HT’s in parallel if there
is some reason to shut down one unit without
affecting the others.
e
r
.
e
Momentary Mode
In Momentary Mode (jumper plug installed on
JMP2) the PS-PRO HT has “memory” — it only
needs a momentary signal from the remote switch
to change its state from ON to OFF. When first
plugged in (or after power is lost and reapplied for
any reason) the stored state is OFF. The unit will
stay off until sequenced ON by a momentary
cohe
kehe
se
o
l
s,
connect the REM to REM, +12V to +12V, GND to
GND terminals of all units together. Be sure
that the mode (momentary or maintained) of all
units is set the same. Set all key lock switches
to REM. Connect a single maintained switch or
one or more momentary switches to the nearest
PS-PRO HT, as discussed in the sections above.
To avoid tripping house breakers, the power
input for each PS-PRO HT should come from a
separate 20 amp AC circuit. If you are unsure
whether your building’s wiring can accommodate
multiple fully-loaded PS-PRO HTs consult a
qualified electrician.
s
Oat
mhe
re
Thh.
This means that even if the unit is sequenced off
by turning the key lock switch to OFF, when the
key lock switch is turned back to REM, the unit
will sequence back on. The unit “remembers” its
state until the incoming power is lost, in which
case it would default back to OFF.
If multiple PS-PRO HTs are controlled by one
or more momentary remote switches, all of the
PS-PRO HTs will change state (from on to off or
vice versa) on each rising edge of the voltage on
the REM IN terminal. The key lock switches on
each unit’s front panel will turn off an individual
unit that is currently on without affecting the
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
other units.
Lightning is a natural phenomenon of over-
whelming force that represents the most dif-
ficult circumstance faced by a power protection
product. The degree of protection a PS-PRO
HT can offer depends on the intensity of the
strike. If lightning strikes a distant power line
and causes a relatively small disturbance to
reach your location, the spike suppressors in
the PS-PRO HT will absorb the excess voltage
invisibly and harmlessly. However, if lightning
strikes the actual building where the PS-PRO HT
is installed (or somewhere very nearby), some
damage may be unavoidable due to the ex-
tremely high voltage and current present. If this
does occur, most likely damage will be limited to
the PS-PRO HT itself and will affect only certain
spike suppression components (called varistors
or MOV’s.) In this “suicide” mode, the PS-PRO
HT may sustain minor damage but generally
will protect all equipment plugged into it from
much more serious and costly damage as long
as that equipment is properly grounded. Proper
grounding requires the use of three-prong AC
cords, and that the building’s outlets are actually
grounded to earth as specified by the National
Electrical Code.
The STATUS lines work the same in either
mode. Each reflects the true state of the unit’s
outlets and is affected by both the “memorized”
state and by the key lock switch. A separate
LED must be used to indicate the status of each
PS-PRO HT.
To address the unusual (hopefully rare) instance
when several PS-PRO HTs in parallel fall out of
sync, resulting in some units turning on and oth-
ers turning off when a remote button is pushed,
the remote signal line has a special feature:
Holding the REM line high for at least 4 seconds
will force all units to the OFF state, putting them
back in sync. This is the only way to re-sync units
other than disconnecting AC power to all units.
Remember — turning any key lock switch to OFF
does not affect the stored state, even though it
will temporarily turn the output of that unit off. If
it is turned back to REM, the PS-PRO HT will
sequence back to ON because the stored state
is still ON.
The above covers the case of multiple units in
parallel (all sequences initiate simultaneously).
See “AC Relay Accessory PS-REL” below for a
discussion of wiring multiple units in series.
Any PS-PRO HT known to have taken a direct
lightning hit should be checked by a qualified
technician or the Furman factory to determine
of the MOV’s need replacement. (If the PS-PRO
HT’s PROTECTION OK indicator is not lit, there
is definitely some damage. Some spike suppres-
sion capability may still be available by MOV
Bank #2, but there is no guarantee of this.)
STATUS Terminal
The STATUS terminal is an output that may be
used to illuminate an LED at the remote location
indicating that the power is available at the PS-
PRO HT’s outlets. If it is high (+5V), the unit is ON
(or at least in the process of sequencing ON); if
low, the unit is OFF (or sequencing OFF). Simply
connect the indicator LED between STATUS
and ground (do not use a series resistor). If the
LED does not light when the switch is in the ON
position check the polarity and reverse the LED
leads if needed.
For optimum protection, you should not rely ex-
clusively on the PS-PRO HT to protect against
a direct lightning hit. The first line of defense
against lightning should be a lightning arrestor
installed on your building’s electrical service
entrance. If your building does not have one,
contact your local power company or an electri-
cal contractor to have one installed.
Effects of Lightning
8
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
Before returning any equipment for repair, please
Three Year Limited Warranty
be sure that it is adequately packed and cush-
ioned against damage in shipment, and that it is
insured. We suggest that you save the original
packaging and use it to ship the product for ser-
vicing. Also, please enclose a note giving your
name, address, phone number and a description
of the problem.
The Furman PS-PRO HT is protected by a
limited three year warranty, covering defects in
materials and workmanship, provided that the
registration card is filled out and returned by
the customer. Otherwise, a one year warranty
applies. Products must have a proof of purchase
from a Furman authorized dealer. During this
period, Furman will make any necessary re-
pairs without charge for parts or labor. Shipping
charges to the factory or repair station must be
prepaid by the owner; return shipping charges
(via UPS Ground) will be paid by Furman.
NOTE: All equipment being returned for repair
must have a ReturnAuthorization (RA) Number.
To get an RA Number, please call the Furman
Service Department, (707) 763-1010, Ext. 120,
or 121, between 8 am and 5 pm U.S. Pacific
Time. Please display your RA Number promi-
nently on the front of all packages.
This warranty applies only to the original owner
and is not transferable. Also, it does not apply to
repairs done other than by the Furman factory
or Authorized Repair Stations.
This warranty shall be cancelable by Furman
at its sole discretion if the PS-PRO HT unit has
been subjected to physical abuse or has been
modified in any way without written authoriza-
tion from Furman. Furman’s liability under this
warranty is limited to repair or replacement of
the defective unit.
Furman will not be responsible for incidental or
consequential damages resulting from the use
or misuse of its products. Some states do not
allow
the exclusion of incidental or consequential
damages, so the above limitations may not
apply to you. This warranty gives you specific
legal rights, and you may also have other rights
which vary from state to state. Warranty claims
should be accompanied by a copy of the original
purchase invoice showing the purchase date (if a
Warranty Registration Card was mailed in at the
time of purchase, this is not necessary). Before
returning any equipment for repair, please read
the important information on service below.
Service
9
Download from Www.Somanuals.com. All Manuals Search And Download.
PS-PRO HT - POWER CONDITIONER/SEQUENCER
PS-PRO HT SPECIFICATIONS
Current rating:
Input Voltage:
20 Amps (2400 Watts at 120 VAC)
85 to 264 VAC without damage
Mains Wiring analyzer: Detects one normal mode and five fault modes
Delay Intervals:
Total elapsed ON or OFF delay time adjustable
from 1-60 seconds, with a single trimpot:
ON sequence:
Delay 1 outlets go on immediately with switch.
Delays between outlets 1 and 2, and 2 and 3,
adjustable from 1-30 seconds each
OFF sequence:
Remote Switch:
Delay 3 outlets go off immediately with switch.
Delays between outlets 3 and 2, and 2 and 1,
same as ON delays
Screw terminals, 2 for switch, 2 additional for
optional LED (22 ga. minimum)
Spike Protection Modes:Line to neutral
Clamping Voltage, all modes: 180V peak
Response time:
1 nanosecond
11,000 amps (8 x 20mS pulse)
Maximum surge current:
Maximum spike energy: 550 joules total
Noise attenuation:
Differential mode: greater than 60 dB; 1 to 200
MHz
Dimensions:
Weight:
1.75”H x 19”W x 10”D.
6 lbs (2.7 kg).
Construction:
Steel chassis, zinc chromate plating; .125”
brushed and black anodized aluminum front panel;
glass epoxy printed circuit boards.
Power Consumption:
11 watts
UL, C-UL.
Safety Agency Approvals:
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Furman Sound, Inc.
1997 South McDowell Blvd.
Petaluma, California 94954-6919 USA
Phone: 707-763-1010
Fax: 707-763-1310
E-mail: [email protected]
091003-D