Dimplex Fan DF3003 User Manual

PRACTICAL USER’S GUIDE  
FOR THE ELECTRIC FIREPLACE  
MODEL NUMBER:  
30” FIREPLACE  
Quality checked by:  
Valued Customer,  
We are pleased that you have chosen to purchase an electric  
fireplace manufactured by Dimplex North America Ltd.  
Over the years, valuable memories will occur around the  
warmth and comfort of your hearth. Thank you for allowing our  
product to be the backdrop for those special moments.  
7205450200REV05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK REFERENCE GUIDE FOR THE DIMPLEX ELECTRIC  
FIREPLACE  
1. Prior to the first use of the fireplace verify the following:  
Are the circuit breakers for the unit on?  
Are the light bulbs in your fireplace loose? (to check, follow the  
instructions for replacing the light bulbs under the maintenance  
section of this manual)  
2. The heater on your fireplace may emit a slight, harmless odor when  
first used. This odor is a normal condition caused by the initial  
heating of internal heater parts and will not occur again.  
3. The information regarding the model of your fireplace can be found  
on the rating plate located on the top of the unit.  
4. If you have any technical questions or concerns regarding the  
operation of your fireplace, or require service contact Dimplex North  
America customer service at 1-888-DIMPLEX (1-888-346-7539) before  
returning the product to the point of purchase.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT INSTRUCTIONS  
SAVE THESE INSTRUCTIONS  
PLEASE RETAIN THIS USER’S GUIDE FOR FUTURE REFERENCE  
When using electrical appliances, basic precautions should always be followed to reduce the  
risk of fire, electric shock, and injury to persons, including the following:  
1. Read all instructions before using the electric fireplace.  
2. The heater is hot when in use. To avoid burns, do not let bare skin touch hot  
surfaces. The trim around the heater outlet becomes hot during heater operation. Keep  
combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains  
at least 3 feet (0.9m) from the front of the unit.  
3. Extreme caution is necessary when any heater is used by or near children or invalids  
and whenever the unit is left operating and unattended.  
4. Always unplug the electric fireplace when not in use.  
5. Do not operate any unit with a damaged cord or plug, or if the heater has malfunctioned,  
or if the electric fireplace has been dropped or damaged in any manner. Return heater  
to authorized service facility for examination, electrical or mechanical adjustment, or  
repair.  
6. Do not use outdoors.  
7. The electric fireplace is not intended for use in bathrooms, laundry areas and similar  
indoor locations. Never locate heater where it may fall into a bathtub or other water  
container.  
8. Do not run the cord under carpeting. Do not cover cord with throw rugs, runners, or the  
like. Arrange cord away from traffic area and where it will not be tripped over.  
9. To disconnect the unit, turn the controls off, then remove the plug from the outlet.  
10.Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this  
may cause an electric shock or fire, or damage to the heater.  
11.To prevent a possible fire, do not block air intake or exhaust in any manner. Do not use  
on soft surfaces, like a bed, where openings may become blocked.  
12.All electrical heaters have hot and arching or sparking parts inside. Do not use in areas  
where gasoline, paint, or flammable liquids are used or stored or where the unit will be  
exposed to flammable vapors.  
13.Do not modify the electric fireplace. Use it only as described in this manual. Any other  
use not recommended by the manufacturer may cause fire, electric shock or injury to  
persons.  
14.Avoid the use of an extension cord. Extension cords may overheat and cause a risk of  
fire. If you must use an extension cord, the cord must be No. 16 AWG minimum size  
and rated no less than 1875 watts.  
15.Do not burn wood or other materials in the electric fireplace.  
16.Do not strike the fireplace glass.  
17.Always use a certified electrician should new circuits or outlets be required.  
18.Always use properly grounded, fused and polarized outlets.  
19.Disconnect all power supply before performing any cleaning, maintenance or relocation  
of the unit.  
20. When transporting or storing the unit and cord, keep in a dry place, free from excessive  
vibration and store so as to avoid damage.  
NOTE: Procedures and techniques that are considered important enough to emphasize.  
CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to  
the equipment.  
WARNING: Procedures and techniques which, if not carefully followed, will expose the user to  
the risk of fire, serious injury, illness or death.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT INSTRUCTIONS  
If you have any questions about our products please have the product model and serial  
numbers available upon calling Dimplex customer service. To locate the model and serial  
number labels see below.  
Model Number  
Serial Number  
Firebox  
Carton  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE  
A 15amp, 120 volt circuit is required. A dedicated circuit is preferred but not essential in all  
cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse  
blows on a regular basis when the heater is operating. Additional appliances on the same  
circuit may exceed the current rating of the circuit breaker.  
WARNING  
Ensure the power cord is not installed so that it is pinched or against a sharp edge and ensure  
that the power cord is stored or secured to avoid tripping or snagging to reduce the risk of fire,  
electric shock or injury to persons.  
Construction and electrical outlet wiring must comply with local building codes and other  
applicable regulations to reduce the risk of fire, electric shock and injury to persons.  
Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric  
shock or injury to persons, always use a licensed electrician.  
SITE SELECTION AND PREPARATION  
This section provides easy step by step instructions for selecting a location and preparing the  
site to install the fireplace into:  
Existing Fireplace  
New wall construction  
Dimplex mantel surround kit or custom made mantel surround  
NOTE  
The fireplace insert comes completely assembled and wired. Some tools may be required to  
prepare the site and assembly/install the trim.  
The dimensions of the fireplace insert are 30” wide X 25 ¼” high X 11 ¼” deep. (FIGURE 1)  
You should allow ¼” around the fireplace insert for ease of installation.  
This fireplace does not require any venting.  
CAUTION  
Clearance for air circulation beneath the fireplace insert is provided by three rubber feet (FIGURE 1).  
DO NOT INSTALL THE FIREPLACE INSERT DIRECTLY ON CARPET OR SIMILAR  
SURFACES WHICH MAY RESTRICT AIR CIRCULATION. If installing the fireplace in a  
carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that all  
three of the insert’s feet rest securely on this surface.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
EXISTING FIREPLACE INSTALLATION  
1. Seal all drafts and vents with non-fibrous insulation materials to prevent chimney debris  
from falling into the fireplace insert. Do not install into an existing fireplace that is prone  
to leaks or dampness.  
2. Cap the top of the chimney flue to prevent rain from entering.  
3. Plan your electrical power supply: (refer to NOTE 1)  
4. The power cord can run along the front of the hearth to an outlet near the fireplace  
(FIGURE 2).  
NOTE 1  
A 15 AMP, 120 VOLT circuit is required. A dedicated circuit is preferred but not essential in  
all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or  
fuse blows on a regular basis when the heater is operating. Additional appliances on the  
same circuit may exceed the current rating of the circuit breaker.  
WARNING  
To prevent personal injury you should hire a professional to cap the chimney flue or cut a  
hole in the existing fireplace for wiring.  
If you return your existing fireplace to its original use (Example wood burning), it should be  
inspected by the local building department prior to use to reduce the risk of fire and  
personal injury.  
NEW WALL CONSTRUCTION  
1. Select a suitable location that is not susceptible to moisture and is away from drapes,  
furniture and high traffic.  
2. Place the fireplace in the desired location to see how it will look in the room.  
3. Mark the desired location on the floor and store the fireplace in a safe, dry and dust free  
location.  
4. Use studs to frame an opening of 30 ½” wide X 25 ¾” high X 11 ¾” deep.  
5. Plan your electrical power supply (refer to NOTE 1)  
Option #1-The power cord can be lead from behind the trim and along the wall to an outlet  
near the fireplace.  
Option #2-A new outlet can be installed inside the new frame construction.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMPLEX MANTEL SURROUND KIT OR CUSTOM MADE MANTEL SURROUND  
1. Select a suitable location that is not susceptible to moisture and is away from drapes,  
furniture and high traffic.  
2. Place the fireplace in the desired location to see how it will look in the room.  
3. For ease of electrical hook up you may wish to locate the fireplace near an existing  
outlet. (refer to NOTE 1)  
4. Store the fireplace in a safe dry and dust free location.  
5. Assemble the mantel surround kit (refer to the mantel assembly instructions) or  
construct the custom surround with an opening of 30 ½” X 11 ¾ ” X 25 ¾”  
WARNING  
Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric  
shock or injury to persons, always use a licensed electrician.  
FIREPLACE INSERT INSTALLATION  
1. Make sure the units MAIN ON/OFF switch is switched OFF (refer to operating  
instruction section).  
2. Plug the unit into a 15Amp/120volt outlet. If the cord does not reach, you may use an  
extension cord rated for a minimum of 1875 watts.  
3. Push the fireplace into the opening being careful not to damage the base of the mantel  
or cabinet so that the fireplace is flush with the mantel or cabinet.  
4. Level the unit with shims if necessary (not provided).  
5. Install the trim onto the fireplace (refer to trim installation instructions).  
WARNING  
Ensure the power cord is not installed so that it is pinched or against a sharp edge and  
ensure that the power cord is stored or secured to avoid tripping or snagging to reduce the  
risk of fire, electric shock or injury to persons.  
OPERATION  
Initializing The Remote Control  
1. Turn on the electrical power at the circuit breaker.  
2. Slide open the battery cover on the back of the remote transmitter.  
3. Install three AAA batteries into the remote control. Replace the battery cover.  
Note:  
The LCD display will flash when new batteries are inserted.  
4. Move the remote transmitter close to the fireplace (less than five feet preferred). Press  
any button on the remote control. The remote is transferring the code to the receiver  
built into the fireplace.  
5. Set the clock by depressing the button marked clock on the transmitter for five seconds.  
The hour display will flash.  
6. Use the up and down buttons to set the hour.  
7. Press the clock button again and the minute display will flash.  
8. Use the up and down buttons to set the minute.  
9. Press the clock button again and the 0F or 0C display will flash.  
10.Use the up and down buttons to select the remote to display temperature in 0F or 0C  
11.Press the clock button again. The remote control is now ready for operation.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Remote Control Operation  
Warning:  
It takes some time for the receiver to respond to the transmitter. Do not press the buttons  
more than once within two seconds for correct operation.  
Note:  
The fireplace has an automatic timer function that will shut your fireplace off if the remote  
control has not been operated within a six-hour period.  
Auto Mode  
Note:  
When auto mode is activated the flame and heat will turn on. The heater will turn on and  
off to keep the room temperature the same as the remote controls set temperature.  
1. Press POWER button to turn unit on. (There may be a slight delay)  
2. Press the UP or DOWN buttons to change the set temperature, if desired.  
3. In auto mode the remote transmitter will automatically turn on the flame and heater  
when the room temperature is below the target temperature and turn off the heater  
ONLY when the room temperature is above the target temperature.  
4. Press POWER button once to turn unit off.  
Timer Mode  
1. You can set the timer to the length of time you want the unit to operate  
2. (1 to 120 minutes).  
3. Press the TIMER button once. The timer display will blink ---  
4. Press the UP and DOWN buttons to adjust the timer display in minutes.  
5. Press the TIMER button once to set the timer.  
6. The timer setting can be reset by pressing the TIMER button and using the DOWN  
button until the timer display reads ----, press the TIMER button once to set the timer.  
7. Press the POWER button to turn the unit on.  
8. The fireplace will automatically shut off when the timer reaches 0 minutes.  
Child Proof Function  
1. Remove the battery cover on the back of the remote control.  
2. Slide the small blue switch down to activate the child proof function.  
3. Child Proof will appear on the display screen and all function on the remote will be  
locked.  
4. To enable normal remote control operation when the child proof function is activated,  
press the up and down buttons in the following sequence,  
UP-DOWN-DOWN-UP-DOWN the remote functions will now operate normally. The  
remote will return to the child proof function if buttons are not pressed after two minutes.  
5. To disable the child proof function remove the battery cover on the back of the remote  
and slide the small blue switch up.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Batteries  
1. The remote control uses 3 AAA size batteries (included). Replace these batteries at  
least every 6 months or when the low battery appears on the remote display screen.  
2. When batteries are removed wait at least 1 minute before replacing with new batteries.  
Code selection  
If the current remote control is interfering with the operation of other remote control devices  
(TV, VCR, garage doors etc.) The code can be changed on the remote.  
To change code:  
1. Remove the battery cover on the back of the remote control.  
2. Slide the four small switches to any configuration other than the factory set code.  
3. Remove the batteries, wait for one minute.  
4. Install the batteries.  
5. Install the battery cover onto the remote.  
6. Reinitialize the remote.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
Electric Fireplace Manual Controls  
A. Manual on/off switch  
1. The fireplace has a manual power ON/OFF switch located on the control panel of the  
fireplace.  
2. To operate press the switch once, to turn the unit on. A red light will illuminate to  
indicate the power is on. Press the switch again to turn the unit off.  
NOTE:  
When the manual power switch is used the heater will run.  
The manual ON/OFF switch is to be used only when the remote transmitter is OFF.  
B. Flame brightness control  
Turn the flame brightness control knob to increase or decrease the brightness of the flame  
and embers.  
C. Flame action control  
Turn the flame action control knob to adjust the flame speed control to the desired level.  
D. Heater override switch  
When the Manual on/off switch is in the on position the heater will run. Turn the heater  
override switch to the off position to shut off the heater.  
NOTE: Ensure that the heater override switch is in the on position for the heater to work  
with the remote control.  
RESETTING THE TEMPERATURE CUTOFF SWITCH  
Should the heater overheat, an automatic cut out will turn the heater off and it will not come  
back on without being reset. It can be reset by switching the MAIN ON/OFF SWITCH to OFF  
and waiting 5 minutes before switching the unit back on.  
CAUTION  
If you need to continuously reset the heater, unplug the unit and call Dimplex North America  
Limited at 1-800-668-6663.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
WARNING  
Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire,  
electric shock or damage to persons.  
LIGHT BULB REPLACEMENT  
Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental  
burning of skin.  
Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity  
and detail of the log exterior disappears. There are two bulbs under the log set which generate  
the flames and embers.  
To open the light bulb area:  
1. Remove the trim by turning the retaining fasteners counterclockwise ¼ turn until the trim  
releases from the firebox using a slotted screwdriver. (FIGURE 1)  
2. Hold the glass in place while removing the retaining clip from the upper center of the  
firebox.  
3. Lift glass out and store in a safe place.  
FIGURE 7  
To replace the bottom light bulbs:  
1. Lift up the front edge of the log until it clears the front tabs. Pull out until the rear tab  
clears the back ledge, then lift out.  
2. Examine the bulbs to determine which bulbs require replacement.  
3. Hold the socket while unscrewing the bulb  
4. Hold the socket while screwing in the new bulb.  
5. Replace the log emberbed by placing the back lip of the log emberbed under the mirror  
then push the front of the log emberbed down into the recess.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
LOWER LIGHT BULB REQUIREMENTS  
Quantity of 4 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt  
rating.  
To replace the top light bulbs:  
1. Locate the two upper bulbs inside the firebox at the top.  
2. Examine the bulbs to determine which bulbs require replacement.  
3. Hold the socket while unscrewing the bulb.  
4. Hold the socket while screwing in the new bulb.  
UPPER LIGHT BULB REQUIREMENTS  
Quantity of 2 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 15 watt  
rating.  
HELPFUL HINTS  
It is a good idea to replace all light bulbs at one time if they are close to the end of their rated  
life. Group replacement will reduce the number of times you need to open the unit to replace  
light bulbs.  
GLASS CLEANING  
The glass is cleaned in the factory during the assembly operation. During shipment,  
installation, handling, etc., the clear door may collect dust particles, these can be removed by  
dusting lightly with a clean dry cloth.  
To remove fingerprints or other marks, the clear door can be cleaned with a damp cloth. The  
clear door should be completely dried with a lint free cloth to prevent water spots. To prevent  
scratching, do not use abrasive cleaners or spray liquids on the clear door surface.  
FIREPLACE SURFACE CLEANING  
Use a cloth dampened with warm water only to clean painted surfaces of the electric fireplace.  
Do not use abrasive cleaners.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIVE YEAR LIMITED WARRANTY  
Products to which this limited warranty applies  
This limited warranty applies to the following applicable models of your newly purchased  
Dimplex electric fireplace SF3003, EF3003, DF3003 and to newly purchased Dimplex  
fireplace surrounds (mantels) and trims. This limited warranty applies only to purchases  
made in any province of Canada except for Yukon Territory, Nunavut, or Northwest  
Territories or in any of the 50 States of the USA (and the District of Columbia) except for  
Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only  
and is not transferable.  
Products excluded from this limited warranty  
Light bulbs are not covered by this limited warranty and are the sole responsibility of the  
owner/purchaser. Products purchased in Yukon Territory, Nunavut, Northwest Territories,  
Hawaii, or Alaska are not covered by this limited warranty. Products purchased in these  
States, provinces, or territories are sold AS IS without warranty or condition of any kind  
(including, without limitation, any implied warranties or conditions of merchantability or fitness  
for a particular purpose) and the entire risk of as to the quality and performance of the  
products is with the purchaser, and in the event of a defect the purchaser assumes the entire  
cost of all necessary servicing or repair.  
What this limited warranty covers and for how long  
Products, other than fireplace surrounds (mantels) and trims, covered by this limited warranty  
have been tested and inspected prior to shipment. Subject to the provisions of this warranty,  
Dimplex warrants such products to be free from defects in material and workmanship for a  
period of 5 years from the date of the first purchase of such products as follows: (a) a repair or  
replacement warranty on defective products or parts, including in-home services, for the first  
two years following the date of first purchase; and (b) thereafter, a replacement of parts  
warranty on defective products and parts (with no in-home services) for the 3 year period  
commencing on the second anniversary of first purchase and ending on the fifth anniversary of  
the date of first purchase.  
Dimplex fireplace surrounds (mantels) and trims covered by this limited warranty have been  
tested and inspected prior to shipment and, subject to the provisions of this warranty, Dimplex  
warrants such products to be free from defects in material and workmanship for a period of 1  
year from the date of first purchase of such products. Warranty services do not include in-  
home services.  
The above section is a summary only of your warranty rights. Please review the  
remaining provisions of this warranty for your specific rights.  
The limited 5 year warranty period for products other than fireplace surrounds (mantels) and  
trims and the limited 1 year warranty period for fireplace surrounds (mantels) and trims also  
applies to any implied warranties that may exist under applicable law. Some jurisdictions do  
not allow limitations on how long an implied warranty lasts, so the above limitation may not  
apply to the purchaser.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
What this limited warranty does not cover  
This limited warranty does not apply to products that have been repaired (except by Dimplex or  
its authorized service representatives) or otherwise altered. This limited warranty does further  
not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation,  
improper maintenance or handling, or operation with an incorrect power source.  
What you must do to get service under this limited warranty  
Defects must be brought to the attention of Dimplex Technical Service by contacting Dimplex  
at 1-888-DIMPLEX (1-888-346-7539), or 1367 Industrial Road, Cambridge Ontario, Canada  
N1R 7G8. Please have proof of purchase, catalogue/model and serial numbers available  
when calling. Limited warranty service requires a proof of purchase of the product.  
What Dimplex will do in the event of a defect  
In the event a product or part covered by this limited warranty is proven to be defective in  
material or workmanship during (i) the 5 year limited warranty period for products other than  
fireplace surrounds (mantels) and trims, and (ii) the 1 year limited warranty period for  
surrounds (mantels) and trims, you have the following rights:  
Limited warranty service will be performed solely by dealers or service agents of  
Dimplex authorized to provide limited warranty services.  
For products (other than surrounds (mantels) and trims) for the period ending at  
midnight on the second anniversary of the date of first purchase, Dimplex will in its  
sole discretion either repair or replace such defective product or part without charge. If  
Dimplex is unable to repair or replace such product or part, or if repair or replacement is  
not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or  
replacement, choose to refund the purchase price for such product or part. This limited  
warranty entitles the purchaser to on-site or in-home warranty services. Accordingly,  
Dimplex will be responsible for all labour and transportation costs associated with the  
repair or replacement of the product or part, except as follows: (i) charges may be levied  
for travel costs incurred to travel to the purchaser's site where the product is located if the  
purchaser's site is beyond 30 miles (48 km) from the closest service depot of Dimplex's  
dealer or service agent; and (ii) the purchaser is solely responsible for providing clear  
access to all serviceable parts of the product.  
For products (other than surrounds (mantels) and trims) for the period  
commencing at 12:01 a.m. on the day after the second anniversary of the first  
purchase and ending at midnight on the fifth anniversary of the date of first  
purchase, this limited warranty entitles the purchaser to replacement parts only without  
charge. If Dimplex is unable to replace such part, or if replacement is not commercially  
practicable or cannot be timely made, Dimplex may, in lieu of replacement, choose to  
refund the purchase price for such part. The purchaser shall not be entitled to on-site or  
in-home warranty services. The purchaser shall be responsible for all expenses incurred  
for the removal of the part and installation of the replacement part including, without  
limitation, all shipping costs and transportation costs to and from the authorized dealer's  
or service agent's place of business and all labour costs. Such costs shall not be the  
responsibility of Dimplex.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
For surrounds (mantels) and trims for the period ending at midnight on the first  
anniversary of the date of first purchase, Dimplex will in its sole discretion either repair  
or replace such defective surrounds (mantels) and trims or part thereof without charge. If  
Dimplex is unable to repair or replace such product or part, or if repair or replacement is  
not commercially practicable or cannot be timely made, Dimplex may, in lieu of repair or  
replacement, choose to refund the purchase price for such product or part. The purchaser  
shall not be entitled to on-site or in-house services. The purchaser is responsible for all  
expenses incurred for repair or replacement of such product or part including, without  
limitation, all shipping costs and transportation costs to and from the authorized dealer's  
or service agent's business and all labour costs. Such costs shall not be the  
responsibility of Dimplex.  
On-site or in-home services not provided under this warranty may be performed at the  
purchaser's specific request and expense at Dimplex’s then-current rates for such  
services.  
What Dimplex and its dealers and service agents are also not responsible for:  
IN NO EVENT WILL DIMPLEX, OR ITS DIRECTORS, OFFICERS, OR AGENTS, BE LIABLE  
TO THE PURCHASER OR ANY THIRD PARTY, WHETHER IN CONTRACT, IN TORT, OR  
ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY,  
CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN  
CONNECTION WITH THE SALE, MAINTENANCE, USE, OR INABILITY TO USE THE  
PRODUCT, EVEN IF DIMPLEX OR ITS DIRECTORS, OFFICERS, OR AGENTS HAVE  
BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF  
SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL  
DIMPLEX, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT  
LOSSES, COSTS, OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE  
PRODUCT.  
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF  
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR  
EXCLUSION MAY NOT APPLY TO THE PURCHASER.  
How State and Provincial law apply  
This limited warranty gives you specific legal rights, and you may also have other rights  
which vary from jurisdiction to jurisdiction. The provisions of the United Nations Convention  
on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of  
products covered by this limited warranty.  
1-888-DIMPLEX  
1-888-346-7539  
1367 Industrial Road  
Cambridge, Ontario  
Canada, N1R 7G8  
Approved for use in the United States and Canada  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Coway Plumbing Product BA08 AE User Manual
Craftsman Snow Blower 53688521 User Manual
Crate Amplifiers Musical Instrument V50 112 User Manual
Danby Refrigerator DFF8801W User Manual
Dixon Lawn Mower 13636 0702 User Manual
D Link Power Supply DPS 510 User Manual
Extron electronic Network Card PoleVault System A V Source Inputs User Manual
FujiFilm Digital Camera 320 IXZ User Manual
GE Cordless Telephone 28802 User Manual
GE Network Card P485 User Manual