Installation and Operating Instructions
08/35058/1
Issue 1
Fan Heaters
Model(s) : DCU18LCD
Dimensions
(millimetres)
H
W
D
295 200 155
Model(s)
Specification
DCU18LCD 1.8kW Electronic LCD Display
Fig. 1
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
IMPORTANT : The wires in this mains lead are coloured in accordance
with the following code :
IMPORTANT SAFETYADVICE
READ THESE INSTRUCTIONS BEFORE USE.
BLUE :
BROWN :
NEUTRAL
LIVE
DO NOT use the heater on deep pile carpets or the long hair
type of rugs, or less than 750mm (30") away from any
overhanging surface. Keep combustible materials such as
drapes and other furnishings clear from the front, sides
and rear of the heater. Do not use heater to dry your laundry.
As the colours of the wires in the mains lead may not correspond with
the coloured markings in your plug, proceed as follows :
Connect the BROWN wire to the terminal marked ‘L’ or coloured RED.
Connect the BLUE wire to the terminal marked ‘N’ or coloured BLACK.
Note : ‘L’ or ‘N’ must not be connected to the EARTH terminal marked
DO NOT use the heater in the immediate surroundings of a
bath, a shower or a swimming pool.
‘E’ or
or coloured GREEN or GREEN AND YELLOW.
DO NOT place the heater directly below a fixed socket outlet.
The socket-outlet must be accessible at all times to enable
the mains plug to be disconnected as quickly as possible.
If in doubt, consult your electrician.
DO NOT COVER or obstruct the air inlet and outlet openings
in any way.
Using the Heater
The heater must be on a flat stable surface when in use.
DO NOT operate the heater with the mains lead overhanging
the front outlet grille.
NEVER leave the heater unattended when it is used by or
near the aged, infirm person’s or children.
If you use this heater in conjunction with an external thermal
control, a programme controller, a timer or any other device
which switches on the heater automatically, observe all
safety warnings AT ALL TIMES since a fire risk exists when
the heater is accidentally covered or displaced.
Fig. 2
Operation
The heater carries the Warning symbol
it must not be covered.
indicating that
When the unit is plugged in and the power switch at the rear of the unit
is switched on a red power light illuminates to indicate that there is
power to the unit. The heater is now in standby mode. The red light will
remain lit until the power switch is switched off or the heater is un-
The instruction leaflet belongs to the appliance and must
be kept in a safe place. If changing owners, the leaflet
must be surrendered to the new owner.
plugged from the outlet. Pressing the
– see Fig. 2, will start the heater
IMPORTANT – If the mains lead of this appliance is damaged,
it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a
hazard.
pressing the again will return the heater to standby mode. Upon
turning the heater on, the unit will be in AUTO heat mode and the LCD
displays a set temperature of 350C. The current air temperature will also
appear on the display. At this point the set temperature can be adjusted
as desired using the “+” button or “-“button – see Fig. 2. Pressing the
MODE button selects the heating mode. Pressing the MODE button will
cycle the heater through the heating modes Low heat/High heat/Fan
only/Auto heat. Pressing the MODE button once will set the heater into
LOW heat mode, pressing twice will select High heat, press again to
select Fan only operation. Pressing the MODE button once more will
return the heater to AUTO heat mode. When the heater is in Low heat,
High Heat or Fan only mode the current air temperature will appear on the
display, the SET TEMP indicator will not be displayed. This heater is
provided with an oscillating function. When the OSC button is pressed
the heater will oscillate back and forth. Press it again and the oscillation
will stop.
Electrical connection
This heater must be used on an A.C.~ supply only and the voltage
marked on the heater must correspond to the supply voltage. This heater
is fitted with a plug incorporating a 13 amp fuse. When replacing the
fuse, a 13 amp fuse approved by ASTA to BS 1362 must be used.
If the plug is not suitable for the socket outlets in your home, the plug
must be cut off and an appropriate one fitted. A plug cut off from a
mains lead will give a shock hazard if inserted into a 13 amp socket
elsewhere in the house. To avoid this, it should be disposed of
immediately.
NOTE: The fuse cover of a non-rewirable plug must be refitted when
changing the fuse. Should the cover become lost, the plug must not be
used until the correct replacement fuse cover is obtained from your
supplier or by contacting our customer helpline.
Note: If switched to standby MODE the heater will retain its last heat
setting. The last heat setting will be cleared from memory once the
power switch at the rear of the heater is switched off or the heater is
unplugged from the outlet.