Cisco Systems Network Card PA 2E3 User Manual

PA-E3 Serial Port Adapter Installation  
and Configuration  
Product Number: PA-E3(=) and PA-2E3(=)  
Platforms Supported: Cisco 7500 Series, Cisco 7000 Series,  
VIP2, Cisco 7200 Series, Cisco uBR7200 Series, Cisco 7100  
Series, Catalyst 5000 Family Switches  
Access Registrar, AccessPath, Any to Any, AtmDirector, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo,  
CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems  
Networking Academy, the Cisco Technologies logo, ConnectWay, ControlStream, Fast Step, FireRunner, GigaStack, IGX, JumpStart, Kernel Proxy, MGX, Natural Network Viewer,  
NetSonar, Network Registrar, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, RouteStream, Secure Script, ServiceWay, SlideCast, SMARTnet, StreamView, The  
Cell, TrafficDirector, TransPath, ViewRunner, VirtualStream, VisionWay, VlanDirector, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live,  
Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and Asist, BPX, Catalyst, Cisco, Cisco IOS, the Cisco  
IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, IOS,  
IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. in the U.S. and certain  
other countries. All other trademarks mentioned in this document are the property of their respective owners. (9905R)  
PA-E3 Serial Port Adapter Installation and Configuration  
Copyright © 1997-1999 Cisco Systems, Inc.  
All rights reserved.  
Corporate Headquarters  
Cisco Systems, Inc.  
170 West Tasman Drive  
San Jose, CA 95134-1706  
USA  
Tel: 408 526-4000  
800 553-NETS (6387)  
Fax: 408 526-4100  
Text Part Number: 78-4482-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
This preface describes how to find additional information on the PA-E3 serial port adapter and other  
Cisco products, services, and documentation. This preface contains the following sections:  
Objectives, page v  
Organization, page v  
Related Documentation, page vi  
Cisco Connection Online, page viii  
Documentation CD-ROM, page viii  
Objectives  
This document describes how to install and configure the PA-E3 serial port adapter (PA-E3[=] and  
PA-2E3[=]) in the following platforms:  
Second-generation Versatile Interface Processor (VIP2) in Cisco 7500 series routers and  
Cisco 7000 series routers with the Cisco 7000 Series Route Switch Processor (RSP7000) and  
Cisco 7000 Series Chassis Interface (RSP7000CI).  
Cisco 7200 series routers, which consist of the two-slot Cisco 7202, four-slot Cisco 7204 and  
Cisco 7204VXR, and six-slot Cisco 7206 and Cisco 7206VXR  
Cisco uBR7200 series universal broadband routers  
Cisco 7100 series routers, which consist of the Cisco 7120 and Cisco 7140  
Catalyst Route Switch Module (RSM)/VIP2 in the Catalyst 5000 family switches  
Organization  
This document is organized into the following chapters:  
Section  
Title  
Description  
Chapter 1  
Chapter 2  
Overview  
Describes the PA-E3 port adapter and  
describes its LED displays, cables, and  
receptacles.  
Preparing for Installation  
Describes safety considerations, tools  
required, and procedures you should  
perform before the actual installation.  
Preface v  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Related Documentation  
Section  
Title  
Description  
Chapter 3  
Chapter 4  
Chapter 5  
VIP2 and the PA-E3  
Provides instructions for installing the  
PA-E3 port adapter on a VIP2 interface  
processor installed in Cisco 7500 or  
Cisco 7000 series routers.  
Catalyst RSM/VIP2 and the PA-E3  
Cisco 7200 Series and the PA-E3  
Provides instructions for installing the  
PA-E3 port adapter on a  
Catalyst RSM/VIP2 installed in  
Catalyst 5000 family switches.  
Provides instructions for installing the  
PA-E3 port adapter on a VIP2 interface  
processor installed in a Cisco 7500 or  
Cisco 7000 series router.  
Chapter 6  
Chapter 7  
Chapter 8  
Cisco uBR7200 Series and the PA-E3 Provides instructions for installing the  
PA-E3 port adapter in the Cisco uBR7200  
series universal broadband router.  
Cisco 7100 Series and the PA-E3  
Configuring the PA-E3 Interfaces  
Provides information on the PA-E3 port  
adapter and its use in Cisco 7100 series  
routers.  
Provides instructions for configuring your  
port adapter on the supported platforms.  
The instructions given in this chapter  
apply to all supported platforms described  
in this document.  
Related Documentation  
Your router and the Cisco IOS software running on it contain extensive features and functionality,  
which are documented in the following resources:  
For Cisco IOS software configuration information and support, refer to the modular  
configuration and modular command reference publications in the Cisco IOS software  
configuration documentation set that corresponds to the software release installed on your  
Cisco hardware.  
Note You can access Cisco IOS software configuration and hardware installation and  
For hardware installation and maintenance information on the Cisco 7000 series and Cisco 7500  
series routers, and the VIP2, refer to the following publications:  
The installation and configuration guide that shipped with your Cisco 7000 series or  
Cisco 7500 series router  
Second-Generation Versatile Interface Processor (VIP2) Installation and Configuration (for  
VIP2 users only)  
For hardware installation and maintenance information on the Catalyst 5000 family switches,  
and the Catalyst RSM/VIP2, refer to the following publications:  
The installation and configuration guide that shipped with your Catalyst 5000 family  
switches  
vi  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Related Documentation  
Route Switch Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note  
(Document Number 78-4780-01) which shipped with your Catalyst RSM/VIP2.  
For hardware installation and maintenance information on Cisco 7100 series routers, refer to the  
Cisco 7100 Series Installation and Configuration Guide publication that shipped with your  
Cisco 7100 series router.  
For information on setting up a Virtual Private Network, see the Cisco 7100 Series VPN  
Configuration Guide.  
For hardware installation and maintenance information on the Cisco 7200 VXR routers, refer to  
the Cisco 7200 VXR Installation and Configuration Guide publication that shipped with your  
Cisco 7200 VXR router.  
For hardware installation and maintenance information on the Cisco 7200 routers, refer to the  
following publications that shipped with your router:  
Cisco 7202 Installation and Configuration Guide  
Cisco 7204 Installation and Configuration Guide  
Cisco 7206 Installation and Configuration Guide  
For hardware installation and maintenance information on the Cisco uBR7200 series routers,  
refer to the Cisco uBR72xx Universal Broadband Router Installation and Configuration Guide  
that shipped with your Cisco uBR7200 series router.  
For international agency compliance, safety, and statutory information for WAN interfaces for  
the Cisco 7500 series routers, Cisco 7000 series routers, Cisco 7200 series routers, Cisco  
ubr7200 series routers, and Cisco 7100 series routers, refer to the following publications:  
Regulatory Compliance and Safety Information for the Cisco 7500 Series Routers  
Regulatory Compliance and Safety Information for the Cisco 7000 Series Routers  
Regulatory Compliance and Safety Information for the Cisco 7200 Series Routers  
Regulatory Compliance and Safety Information for the Cisco 7100 Series Routers  
Regulatory Compliance and Safety Information for the Cisco uBR72xx Universal  
Broadband Router  
Note The regulatory compliance and safety information documentation listed above applies to the  
Catalyst 5000 family switches and the Catalyst RSM/VIP2.  
For port adapter hardware and memory configuration guidelines for the Cisco 7200 series  
routers, refer to the document Cisco 7200 Series Port Adapter Hardware Configuration  
Guidelines.  
To view Cisco documentation or obtain general information about the documentation, see the “Cisco  
Connection Online” section on page viii or the “Related Documentation” section on page vi, or call  
customer service at 800 553-6387 or 408 526-7208. Customer service hours are 5:00 a.m. to  
6:00 p.m. Pacific time, Monday through Friday (excluding Cisco-observed holidays). You can also  
send e-mail to [email protected].  
Preface vii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cisco Connection Online  
Cisco Connection Online  
Cisco Connection Online (CCO) is Cisco Systems’ primary, real-time support channel. Maintenance  
customers and partners can self-register on CCO to obtain additional information and services.  
Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added  
services to Cisco’s customers and business partners. CCO services include product information,  
product documentation, software updates, release notes, technical tips, the Bug Navigator,  
configuration notes, brochures, descriptions of service offerings, and download access to public and  
authorized files.  
CCO serves a wide variety of users through two interfaces that are updated and enhanced  
simultaneously: a character-based version and a multimedia version that resides on the World Wide  
Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet  
e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version  
of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well  
as hyperlinks to related information.  
You can access CCO in the following ways:  
Telnet: cco.cisco.com  
Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the following  
terminal settings: VT100 emulation; databits: 8; parity: none; stop bits: 1; and connection rates up  
to 28.8 kbps.  
For a copy of CCO’s Frequently Asked Questions (FAQ), contact [email protected]. For  
additional information, contact [email protected].  
If you are a network administrator and need personal technical assistance with a Cisco product that  
is under warranty or covered by a maintenance contract, contact Cisco’s Technical Assistance Center  
(TAC) at 800 553-2447, 408 526-7209, or [email protected]. To obtain general information about  
Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or  
Documentation CD-ROM  
Cisco documentation and additional literature are available in a CD-ROM package, which ships with  
your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated  
monthly. Therefore, it might be more current than printed documentation. To order additional copies  
of the Documentation CD-ROM, contact your local sales representative or call customer service.  
The CD-ROM package is available as a single package or as an annual subscription. You can also  
If you are reading Cisco product documentation on the World Wide Web, you can submit comments  
electronically. Click Feedback in the toolbar and select Documentation. After you complete the  
form, click Submit to send it to Cisco. We appreciate your comments.  
viii  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 1  
Overview  
This chapter describes the one-port PA-E3 and two-port PA-2E3 E3 serial port adapters. This  
chapter contains the following sections:  
Port Adapter Overview, page 1-1  
PA-E3 Serial Port Adapter Features, page 1-2  
Management Information Base, page 1-3  
PA-E3 Port Adapter LEDs, page 1-3  
PA-E3 Receptacles and Cables, page 1-4  
Interoperability Guidelines for PA-E3 DSUs, page 1-5  
Port Adapter Overview  
The PA-E3 is a single-width, one-port or two-port module that integrates data service unit (DSU)  
functionality into the Cisco router (see Figure 1-1 and Figure 1-2). The module provides one or two  
high-speed serial E3 interfaces on:  
Cisco 7100 series routers  
Cisco 7200 series routers  
Cisco uBR7200 series routers  
Second-generation Versatile Interface Processors (VIP2) in all Cisco 7000 series and Cisco 7500  
series routers  
Catalyst RSM/VIP2 in the Catalyst 5000 family switches  
Note Port adapters have a handle attached, but this handle is occasionally not shown in figures in  
this publication to allow a full view of detail on the port adapter’s faceplate.  
Overview 1-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Adapter Overview  
Figure 1-1  
One-Port PA-E3 Serial Port Adapter  
E3 SERIAL  
RL  
FERF  
RCLK  
OOF  
XMTR  
RCVR  
ENABLED  
LL  
AIS  
Figure 1-2  
Two-Port PA-2E3 Serial Port Adapter  
2E3 SERIAL  
RL  
FERF  
RL  
RCLK  
OOF  
FERF  
RCLK  
XMTR  
RCVR  
XMTR  
RCVR  
ENABLED  
LL  
LL  
AIS  
AIS  
OOF  
The one-port PA-E3 provides two network interfaces per VIP2 for Cisco 7000 series and  
Cisco 7500 series routers and the Catalyst RSM/VIP2 for Catalyst 5000 family switches, and one  
high-speed interface on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers.  
The two-port PA-2E3 provides four network interfaces per VIP2 for Cisco 7000 series and  
Cisco 7500 series routers and the Catalyst RSM/VIP2 for Catalyst 5000 family switches, and two  
high-speed interfaces on the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series  
routers.  
Serial network interfaces reside on modular port adapters, which provide a direct connection  
between the high-speed bus in the router and the external networks. The PA-E3 provides a  
full-duplex synchronous serial E3 interface for transmitting and receiving data at rates of up to  
34 megabits per second (Mbps).  
The port adapter supports both 16- and 32-bit cyclic redundancy checks (CRCs). The default is  
16-bit CRCs; to enable 32-bit CRCs, you use a configuration command. For a description of the CRC  
function, see the “Configuring Cyclic Redundancy Checks” section on page 8-10.  
Note Although the VIP2 and Catalyst RSM/VIP2 supports online insertion and removal (OIR),  
individual port adapters do not. To replace port adapters, you must first remove the VIP2 and  
Catalyst RSM/VIP2 from the chassis, and then replace port adapters as required.  
The Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers support the OIR of all  
port adapter types.  
1-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PA-E3 Serial Port Adapter Features  
PA-E3 Serial Port Adapter Features  
The PA-E3 serial port adapter has the following features:  
Single-width port adapter for the VIP2 in all Cisco 7000 series and Cisco 7500 routers, and in  
Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers  
Single-width port adapter for the Catalyst RSM/VIP2 in the Catalyst 5000 family switches  
Single- or double-port E3 rate (34 Mbps) connectivity  
Full-duplex synchronous serial E3 interface  
High-speed High-Level Data Link Control (HDLC) data  
Integrated data service unit (DSU) functionality  
Support for 16- and 32-bit cyclic redundancy checks (CRCs)  
Support for G.751 framing or bypass framing  
Support for ATM-DXI, Frame Relay, HDLC, SMDS, and PPP serial encapsulations  
Support for national service bits  
Support for E3 MIB (RFC 1407)  
Support for remote and local loopback  
HDB3 line coding  
Scrambling and bandwidth reduction  
Online insertion and removal (OIR)  
Management Information Base  
Management Information Base (MIB) attributes are readable and writable across the Interim Local  
Management Interface (ILMI) through use of the Simple Network Management Protocol (SNMP).  
The one-port PA-E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407).  
The two-port PA-2E3 supports MIB-II (RFC 1213) and the E3 interface MIB (RFC 1407).  
PA-E3 Port Adapter LEDs  
The one-port PA-E3 port adapter has one status LED and six uplink port status LEDs (RCLK, FERF,  
OOF, AIS, RL, and LL) for the serial E3 port. (See Figure 1-3.)  
Figure 1-3  
One-Port PA-E3 Port Adapter LEDsPartial Front View Shown  
E3 SERIAL  
LEDs  
Overview 1-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PA-E3 Receptacles and Cables  
The two-port PA-2E3 port adapter has one status LED and six uplink port status LEDs (RCLK,  
FERF, OOF, AIS, RL, and LL) for each serial E3 port. (See Figure 1-4.)  
Figure 1-4  
Two-Port PA-2E3 Port Adapter LEDs—Partial Front View Shown  
2E3 SERIAL  
LEDs  
After system initialization, the ENABLED LED goes on, indicating that the port adapter has been  
enabled for operation.  
The following conditions must be met before the PA-E3 port adapter is enabled:  
The port adapter contains a valid microcode version that has been downloaded successfully.  
For Cisco 7000 and 7500 series routers, the port adapter is correctly connected to the VIP2 and  
the midplane and is receiving power in the Cisco router.  
For the Catalyst 5000 family switches, the port adapter is correctly connected to the  
Catalyst RSM/VIP2 and is receiving power in the switch.  
The bus recognizes the port adapter.  
If any of these conditions are not met, or if the initialization fails for other reasons, the ENABLED  
LED does not go on.  
Table 1-1 describes the PA-E3 LEDs.  
Table 1-1  
PA-E3 Port Adapter LEDs  
Color State Description  
Name  
ENABLED  
Uplink port status  
RCLK  
Green  
On  
Indicates that the port adapter is ready.  
Green  
On  
Indicates that a receive clock has been detected.  
FERF  
Yellow On  
Indicates that Framer detected Far End Receive  
Failure.  
OOF  
AIS  
Yellow On  
Yellow On  
Indicates that Framer detected Out of Frame.  
Indicates that Framer detected Alarm Indication  
Signal.  
RL  
LL  
Yellow On  
Yellow On  
Indicates that port is in remote loopback mode.  
Indicates that port is in local loopback mode.  
PA-E3 Receptacles and Cables  
The serial interface cable for the PA-E3, which is a 75-ohm coaxial cable, is used to connect your  
router to a serial E3 network. Serial cables conform to EIA/TIA-612 and EIA/TIA-613  
specifications. The serial ports on the PA-E3 are considered to be DTE devices.  
1-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interoperability Guidelines for PA-E3 DSUs  
On a single PA-E3, there are one or two serial E3 ports, each with two connectors (receive and  
transmit), where you connect the Cisco 75-ohm coaxial cable. The 75-ohm coaxial cable  
(Cisco part number CAB-ATM-DS3/E3) for the PA-E3 is available only from Cisco Systems; it is  
not available from outside commercial cable vendors.  
The Cisco E3 75-ohm coaxial cable, which comes with an attached ferrite sleeve (see Figure 1-5),  
is available only in 10-foot (3.05-meter) lengths. The typical maximum distance between stations  
for E3 transmissions is 1300 feet (396 meters).  
Note For E3 (75-ohm) connections, you must have ferrite beads on the 75-ohm coaxial cable and  
EMI decoupling clips on the Rcvr end of the cable (see Figure 1-5) if compliance with European  
certification standards for emission control is required (EN55022/CISPR22 Class B for radiated  
emission levels).  
Figure 1-5  
PA-E3 Cables  
EMI decoupler clip  
RCLK FERF  
XMTR  
RCVR  
T3  
I
OF  
Ferrite beads  
You can test the DTE-to-DCE cable connection by using the loopback dte command. See the  
“Using the loopback Command to Verify the Physical Interface” section on page 8-20 for more  
information.  
Interoperability Guidelines for PA-E3 DSUs  
The PA-E3 supports several types of integrated DSUs. Table 1-2 lists the feature compatibilities of  
the PA-E3 DSUs.  
Table 1-2  
Feature Compatibilities of PA-E3 DSUs  
Full Rate  
Support  
Scrambling  
Support  
Subrate  
Support  
DSU  
1
1
DL3100E  
Kentrox  
Yes  
Yes  
No  
Yes  
2
2
Yes  
Yes  
1
DL3100E does not support scrambling. However, the PA-E3 can turn on scrambling  
in DSU mode 0 for connecting to another PA-E3. The PA-E3 supports either  
scrambling (in mode 0) or DL3100E subrate, not both at the same time.  
2
The PA-E3 supports either scrambling or Kentrox subrate, not both at the same time.  
Overview 1-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Interoperability Guidelines for PA-E3 DSUs  
1-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 2  
Preparing for Installation  
This chapter describes the general equipment, safety, and site preparation requirements for installing  
PA-E3 port adapters.  
Parts and Tools Required, page 2-1  
Software and Hardware Requirements, page 2-2  
Safety Guidelines, page 2-3  
Compliance Information, page 2-6  
Parts and Tools Required  
You need the following tools and parts to install a port adapter. If you need additional equipment,  
contact a service representative for ordering information.  
PA-E3 serial port adapter and one of the following:  
VIP2-15(=) if you are installing only one PA-E3 port adapter; otherwise, we recommend a  
VIP2-40(=) or VIP2-50(=).  
Catalyst RSM/VIP2-15(=) if you are installing only one PA-E3 port adapter; otherwise, we  
recommend a Catalyst RSM/VIP2-40(=).  
Cisco 7100 series router with at least one available port adapter slot.  
Cisco 7200 series router with at least one available port adapter slot.  
Cisco uBR7200 series router with at least one available port adapter slot.  
Cisco 75-ohm coaxial serial interface cables. (The PA-E3’s 75-ohm cables are available only  
from Cisco Systems; they are not available from outside commercial vendors.)  
Number 1 Phillips screwdriver and a 3/16-inch flat-blade screwdriver (for VIP2 and  
Catalyst RSM/VIP2 installation only).  
Your own ESD-prevention equipment or the disposable grounding wrist strap included with all  
upgrade kits, field-replaceable units (FRUs), and spares.  
Preparing for Installation 2-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Software and Hardware Requirements  
Software and Hardware Requirements  
Table 2-1 lists the minimum Cisco IOS software release required to use the one-port PA-E3 and  
two-port PA-2E3 in supported router platforms.  
Table 2-1  
Platforms  
PA-E3 and PA-2E3 Software Requirements  
Recommended Minimum Cisco IOS Release  
Cisco 7000 and Cisco 7500 Series  
PA-E3  
PA-2E3  
• With VIP2-15(=) or VIP2-40(=)  
Cisco IOS Release 11.1(13)CA or a later  
release of Cisco IOS Release 11.1 CA  
Cisco IOS Release 11.1(16)CA or a later  
release of Cisco IOS Release 11.1 CA  
• With VIP2-50(=)  
Cisco IOS Release 11.1(14)CA or a later  
release of Cisco IOS Release 11.1 CA  
Cisco IOS Release 11.1(16)CA or a later  
release of Cisco IOS Release 11.1 CA  
Cisco 7200 Series  
• Cisco 7204VXR and Cisco 7206VXR  
Cisco IOS Release 12.0(2)XE2 or a later  
release of Cisco IOS Release 12.0 XE  
Cisco IOS Release 12.0(2)XE2 or a later  
release of Cisco IOS Release 12.0 XE  
Cisco IOS Release 12.0(3)T or a later release Cisco IOS Release 12.0(3)T or a later release  
of Cisco IOS Release 12.0 T  
of Cisco IOS Release 12.0 T  
• Cisco 7204 and Cisco 7206  
• Cisco 7202  
Cisco IOS Release 11.1(16)CA or a later  
release of Cisco IOS Release 11.1 CA  
Cisco IOS Release 11.1(16)CA or a later  
release of Cisco IOS Release 11.1 CA  
Cisco IOS Release 11.1(19)CC1 or a later  
release of Cisco IOS Release 11.1 CC  
Cisco IOS Release 11.3(4)AA or a later  
release of Cisco IOS Release 11.3 AA  
Cisco IOS Release 11.1(19)CC1 or a later  
release of Cisco IOS Release 11.1 CC  
Cisco IOS Release 11.3(4)AA or a later  
release of Cisco IOS Release 11.3 AA  
Cisco uBR7200 Series  
• Cisco uBR7246 and Cisco uBR7223  
Cisco IOS Release 12.0(2)XA or a later  
release of Cisco IOS Release 12.0 XA  
Cisco IOS Release 12.0(2)XA or a later  
release of Cisco IOS Release 12.0 XA  
Cisco 7100 Series  
• Cisco 7120 series and Cisco 7140 series  
Cisco IOS Release 12.0(4)XE or a later  
release of Cisco IOS Release 12.0 XE  
Cisco IOS Release 12.0(5)T or a later release  
of Cisco IOS Release 12.0 T  
Catalyst 5000 Family Switches  
• With Catalyst RSM/VIP2-15(=) or  
Catalyst RSM/VIP2-40(=)  
Cisco IOS Release 12.0(1) or a later release of Cisco IOS Release 12.0(1) or a later release of  
Cisco IOS Release 12.0 Cisco IOS Release 12.0  
Caution The VIP2 requires that the host Cisco 7000 series router have the RSP7000 and RSP7000CI  
installed. The VIP2 does not operate properly with the Route Processor (RP), Switch Processor (SP), or  
Silicon Switch Processor (SSP) installed in the host Cisco series router.  
The PA-E3 is considered a high-bandwidth port adapter; therefore at a minimum, Cisco recommends  
that the PA-E3 be installed on the VIP2-15 or Catalyst RSM/VIP2-15 motherboard (with 1 MB of  
SRAM and 8 MB of DRAM). Installation of the PA-E3 on the VIP2-10 (with 512 KB of SRAM and  
8 MB of DRAM) is not recommended.  
2-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Guidelines  
Note The VIP2 and Catalyst RSM/VIP2 supports online insertion and removal (OIR), but  
individual port adapters do not. To replace the port adapters, you must first remove the VIP2 or  
Catalyst RSM/VIP2 from the chassis and then replace port adapters as required. OIR is supported  
for port adapters in the Cisco 7100 series, Cisco 7200 series, and Cisco uBR7200 series routers.  
Port adapters have a handle attached, but this handle is occasionally not shown in illustrations in this  
publication to allow a full view of detail on the port adapter’s faceplate.  
In the Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco uBR7200 series routers and  
Catalyst 5000 family switches, there are no restrictions on slot locations or sequence; however, in  
the Cisco 7200 series routers, there are specific configuration guidelines that must be observed for  
high-bandwidth port adapters.  
For specific Cisco 7200 series hardware configuration information and for memory configuration  
guidelines for Cisco 7200 series routers, refer to the document Cisco 7200 Series Port Adapter  
Hardware Configuration Guidelines, which shipped with your Cisco 7200 series chassis and is also  
available on the Cisco Connection Documentation, Enterprise Series CD-ROM.  
To determine if your Cisco 7000 series, Cisco 7100 series, Cisco 7500 series, Cisco 7200 series, or  
Cisco uBR7200 series router, or the Catalyst RSM/VIP2 is compatible with the PA-E3, use the show  
version command to display the current hardware configuration of the router, including the system  
software version that is currently loaded and running.  
You can check the version of the default ROM image by removing the board and checking the ROM  
labels, or by configuring the interface or system software to boot from ROM, restarting the system,  
and using the show version command to check the running version.  
To display the current system software version, use the show version command. In the following  
example, the running system software is Release 11.1(16)CA.  
Router> show version  
Cisco Internetwork Operating System Software  
IOS (tm) GS Software, Version 11.1(16)CA  
Synced to mainline version: 11.1(10.5)  
Copyright (c) 1986-1997 by cisco Systems, Inc.  
Compiled Thu 22-May-97 14:32  
If your system lacks the required system software and microcode, contact a customer service  
representative for upgrade information.  
Safety Guidelines  
The following are safety guidelines that you should follow when working with any equipment that  
connects to electrical power or telephone wiring.  
Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before  
you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with  
standard practices for preventing accidents. To see translations of the warnings that appear in this publication,  
refer to the Regulatory Compliance and Safety Information document that accompanied this device.  
Waarschuwing Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die  
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust  
te zijn van de bij elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van  
standaard maatregelen om ongelukken te voorkomen. Voor vertalingen van de waarschuwingen die  
Preparing for Installation 2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Guidelines  
in deze publicatie verschijnen, kunt u het document Regulatory Compliance and Safety Information  
(Informatie over naleving van veiligheids- en andere voorschriften) raadplegen dat bij dit toestel is  
ingesloten.  
Varoitus Tämä varoitusmerkki merkitsee vaaraa. Olet tilanteessa, joka voi johtaa ruumiinvammaan.  
Ennen kuin työskentelet minkään laitteiston parissa, ota selvää sähkökytkentöihin liittyvistä  
vaaroista ja tavanomaisista onnettomuuksien ehkäisykeinoista. Tässä julkaisussa esiintyvien  
varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety  
Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta).  
Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation  
pouvant causer des blessures ou des dommages corporels. Avant de travailler sur un équipement,  
soyez conscient des dangers posés par les circuits électriques et familiarisez-vous avec les  
procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des  
traductions d’avertissements figurant dans cette publication, consultez le document Regulatory  
Compliance and Safety Information (Conformité aux règlements et consignes de sécurité) qui  
accompagne cet appareil.  
Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer  
Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie  
sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur  
Vermeidung von Unfällen bewußt. Übersetzungen der in dieser Veröffentlichung enthaltenen  
Warnhinweise finden Sie im Dokument Regulatory Compliance and Safety Information  
(Informationen zu behördlichen Vorschriften und Sicherheit), das zusammen mit diesem Gerät  
geliefert wurde.  
Avvertenza Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare  
infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli  
relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti.  
La traduzione delle avvertenze riportate in questa pubblicazione si trova nel documento Regulatory  
Compliance and Safety Information (Conformità alle norme e informazioni sulla sicurezza) che  
accompagna questo dispositivo.  
Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan føre til  
personskade. Før du utfører arbeid på utstyr, må du vare oppmerksom på de faremomentene som  
elektriske kretser innebærer, samt gjøre deg kjent med vanlig praksis når det gjelder å unngå ulykker.  
Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i  
dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og  
sikkerhetsinformasjon) som ble levert med denne enheten.  
Aviso Este símbolo de aviso indica perigo. Encontra-se numa situação que lhe poderá causar danos  
físicos. Antes de começar a trabalhar com qualquer equipamento, familiarize-se com os perigos  
relacionados com circuitos eléctricos, e com quaisquer práticas comuns que possam prevenir  
possíveis acidentes. Para ver as traduções dos avisos que constam desta publicação, consulte o  
documento Regulatory Compliance and Safety Information (Informação de Segurança e Disposições  
Reguladoras) que acompanha este dispositivo.  
¡Advertencia! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física.  
Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y  
familiarizarse con los procedimientos estándar de prevención de accidentes. Para ver una traducción  
de las advertencias que aparecen en esta publicación, consultar el documento titulado Regulatory  
Compliance and Safety Information (Información sobre seguridad y conformidad con las  
disposiciones reglamentarias) que se acompaña con este dispositivo.  
2-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Equipment Guidelines  
Varning! Denna varningssymbol signalerar fara. Du befinner dig i en situation som kan leda till  
personskada. Innan du utför arbete på någon utrustning måste du vara medveten om farorna med  
elkretsar och känna till vanligt förfarande för att förebygga skador. Se förklaringar av de varningar  
som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information  
(Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning.  
Electrical Equipment Guidelines  
Follow these basic guidelines when working with any electrical equipment:  
Before beginning any procedures requiring access to the chassis interior, locate the emergency  
power-off switch for the room in which you are working.  
Disconnect all power and external cables before moving a chassis.  
Do not work alone when potentially hazardous conditions exist and never assume that power has  
been disconnected from a circuit; always check.  
Do not perform any action that creates a potential hazard to people or makes the equipment  
unsafe. Carefully examine your work area for possible hazards such as moist floors, ungrounded  
power extension cables, and missing safety grounds.  
Telephone Wiring Guidelines  
Use the following guidelines when working with any equipment that is connected to telephone  
wiring or to other network cabling:  
Never install telephone wiring during a lightning storm.  
Never install telephone jacks in wet locations unless the jack is specifically designed for wet  
locations.  
Never touch uninsulated telephone wires or terminals unless the telephone line has been  
disconnected at the network interface.  
Use caution when installing or modifying telephone lines.  
Preventing Electrostatic Discharge Damage  
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are  
improperly handled, results in complete or intermittent failures. Port adapters and processor modules  
consist of printed circuit boards that are fixed in metal carriers. Electromagnetic interference (EMI)  
shielding and connectors are integral components of the carrier. Although the metal carrier helps to  
protect the board from ESD, use a preventive antistatic strap during handling.  
The following are guidelines for preventing ESD damage:  
Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.  
Connect the equipment end of the strap to an unfinished chassis surface.  
When installing a component, use any available ejector levers or captive installation screws to  
properly seat the bus connectors in the backplane or midplane. These devices prevent accidental  
removal, provide proper grounding for the system, and help to ensure that bus connectors are  
properly seated.  
When removing a component, use any available ejector levers or captive installation screws to  
release the bus connectors from the backplane or midplane.  
Preparing for Installation 2-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance Information  
Handle carriers by available handles or edges only; avoid touching the printed circuit boards or  
connectors.  
Place a removed component board-side-up on an antistatic surface or in a static shielding  
container. If you plan to return the component to the factory, immediately place it in a static  
shielding container.  
Avoid contact between the printed circuit boards and clothing. The wrist strap only protects  
components from ESD voltages on the body; ESD voltages on clothing can still cause damage.  
Never attempt to remove the printed circuit board from the metal carrier.  
Caution For safety, periodically check the resistance value of the antistatic strap. The measurement should  
be between 1 and 10 megohms (Mohm).  
Compliance Information  
The following sections provide compliance information that applies to the FCC and the PA-E3 serial  
port adapter, which has been designed to meet these requirements. Modifications to this product that  
are not authorized by Cisco Systems, Inc., could void the various approvals and negate your  
authority to operate the product.  
BABT Compliance  
The BABT607116 marking on the PA-E3 signifies that it meets United Kingdom directive 607116  
and has been designed to BABT standards. The BABT label is located on the top of the PA-E3;  
Figure 2-1 shows the BABT label for the PA-E3.  
Figure 2-1  
BABT Label for PA-E3 Serial Port Adapter  
607116  
ITI-T Compliance  
ITI-T recommendation G.823 specifies that it is important to restrict jitter gain. Figure 4 of G.823  
shows a typical jitter transfer characteristic. (Note that small jitter gain is allowed.) British Standard  
6328: Section 8.1 1990 gives the allowable gain as 0.5 dB. The PA-E3’s line mode clocking complies  
with these sections.  
TBR24 Compliance  
When the PA-E3 is in line clocking mode, jitter is not attenuated, and any jitter received is transferred  
to the line. If input jitter exceeds the limits of TBR24, then output jitter will not meet TBR24 transfer  
specifications. Line clocking mode is intended for use only where the connection involves a single  
hop, and where clock timing will not be transferred to other network equipment.  
When not in line clocking mode, the PA-E3 complies with TBR24 standards.  
2-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 3  
VIP2 and the PA-E3  
This chapter provides information on the PA-E3 serial port adapter and its use on the VIP2 in  
Cisco 7000 series and Cisco 7500 series routers. This chapter contains the following sections:  
Overview, page 3-1  
Removing a Port Adapter, page 3-4  
Installing a Port Adapter, page 3-5  
Overview  
The PA-E3 is used on the VIP2 in Cisco 7000 series and Cisco 7500 series routers and can be  
installed in either port adapter slot 0 or slot 1 on the VIP2 motherboard.  
Note You can have up to three E3 serial interfaces on a VIP2 motherboard. Cisco recommends a  
configuration of one PA-E3 (with one E3 serial interface) and one PA-2E3 (with two serial  
interfaces) for a total of three E3 serial interfaces per VIP2.  
Figure 3-1 shows two one-port PA-E3 port adapters installed in port adapter slot 0 and slot 1, on a  
VIP2-15 or VIP2-40.  
VIP2 and the PA-E3 3-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Figure 3-1  
VIP2-15 or VIP2-40 with One-Port PA-E3 Port Adapters in Port Adapter Slots 0  
and 1  
CPU  
Boot ROM  
Bus connector  
U6  
DRAM  
SIMMs  
U2  
U4  
SRAM  
DIMM U5  
PA-E3 in port  
adapter slot 0  
PA-E3 in port  
adapter slot 1  
E3 SERIAL  
T3 SERIAL  
RCLK FERF RL  
RCLK FERF RL  
ENABLED  
RCVR  
ENABLED  
RCVR  
XMTR  
XMTR  
LL  
LL  
AIS  
AIS  
OOF  
OOF  
Port adapter  
handles not  
shown  
RCLK FERF RL  
LL  
AIS  
OOF  
Note Port adapters have a handle attached, but this handle is not shown to allow a full view of detail  
on each port adapter’s faceplate.  
3-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Figure 3-2 shows two one-port E3 port adapters installed in port adapter slots 0 and 1, on a VIP2-50.  
Figure 3-2  
VIP2-50 with One-Port PA-E3 Port Adapters in Port Adapter Slots 0 and 1  
CPU  
Boot ROM  
Bus connector  
SRAM  
daughter  
card  
SDRAM DIMM  
PA-E3 in  
port adapter  
slot 1  
PA-E3 in  
port adapter  
slot 0  
E3 SERIAL  
T3 SERIAL  
RCLK FERF RL  
RCLK FERF RL  
ENABLED  
RCVR  
ENABLED  
RCVR  
XMTR  
XMTR  
LL  
LL  
AIS  
AIS  
OOF  
OOF  
Port adapter handles not shown  
RCLK FERF RL  
LL  
AIS  
OOF  
Depending on the circumstances, you might need to install a new port adapter on a VIP2  
motherboard or replace a failed port adapter in the field. In either case, you need a number 1 Phillips  
screwdriver, an antistatic mat on which you can place the removed interface processor, and an  
antistatic container in which you can place a failed port adapter for shipment back to the factory.  
Note The PA-E3 can be installed on a VIP2-15, VIP2-20, VIP2-40, or VIP2-50 motherboard;  
however, installation on the VIP2-10 is not recommended.  
Caution To prevent system problems, do not remove port adapters from the VIP2 motherboard or  
attempt to install other port adapters on the VIP2 motherboard while the system is operating. To  
install or replace port adapters, first remove the VIP2 from its interface processor slot.  
Note Each port adapter circuit board is mounted to a metal carrier and is sensitive to ESD damage.  
The following procedures should be performed by a Cisco-certified service provider only. The VIP2  
supports online insertion and removal (OIR), but individual port adapters do not. To replace  
port adapters, you must first remove the VIP2 from the chassis and then install or replace port  
adapters as required. If a blank port adapter is installed on the VIP2 in which you want to install a  
new port adapter, you must first remove the VIP2 from the chassis and then remove the blank  
port adapter.  
VIP2 and the PA-E3 3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
When only one port adapter is installed on a VIP2, a blank port adapter must fill the empty slot. This  
allows the VIP2 and router chassis to conform to electromagnetic interference (EMI) emissions  
requirements, and encourages air to flow through the chassis properly. If you plan to install a new  
port adapter, you must first remove the blank port adapter.  
Removing a Port Adapter  
Following is the standard procedure for removing any type of port adapter on the VIP2:  
Step 1  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Note If you want to install a new port adapter on a VIP2 with a single port adapter, you  
must first remove the blank port adapter from the port adapter slot in which you want to  
install the new port adapter.  
Step 2  
Step 3  
For a new port adapter installation or a port adapter replacement, disconnect any interface  
cables from the ports on the front of the port adapter, although this is not required. You  
can remove VIP2s with cables attached; however, we do not recommend it.  
To remove the VIP2 from the chassis, follow the steps in the section “Removing a VIP2”  
in the configuration note Second-Generation Versatile Interface Processor (VIP2)  
Installation and Configuration, which shipped with your VIP2. Place the removed VIP2  
on an antistatic mat.  
Step 4  
Locate the screw at the rear of the port adapter (or blank port adapter) to be replaced.  
(See Figure 3-3.) This screw secures the port adapter (or blank port adapter) to its slot.  
Figure 3-3  
Location of Port Adapter ScrewPartial Port Adapter View  
Screw  
Step 5  
Step 6  
Remove the screw that secures the port adapter (or blank port adapter).  
With the screw removed, grasp the handle on the front of the port adapter (or blank  
port adapter) and carefully pull it out of its slot, away from the edge connector at the rear  
of the slot. (See Figure 3-4.)  
3-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 3-4  
Pulling a Port Adapter Out of a SlotPartial Port Adapter View  
Step 7  
If you removed a port adapter, place it in an antistatic container for safe storage or  
shipment back to the factory. If you removed a blank port adapter, no special handling is  
required; however, store the blank port adapter for potential future use.  
This completes the procedure for removing a new port adapter on a VIP2.  
Installing a Port Adapter  
Following is the standard procedure for replacing a port adapter on the VIP2:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Remove the new port adapter from its antistatic container and position it at the opening  
of the slot.  
Step 3  
Carefully align the port adapter carrier between the upper and the lower edges of the port  
adapter slot, as shown in Figure 3-5.  
VIP2 and the PA-E3 3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 3-5  
Aligning a Port Adapter in a Port Adapter Slot  
Carrier  
Upper edge  
Lower edge  
Caution To prevent jamming the carrier between the upper and lower edges of the port adapter slot  
and to ensure that the edge connector at the rear of the port adapter mates with the connector at the  
rear of the port adapter slot, make certain that the leading edges of the carrier are between the upper  
and lower slot edges, as shown in the cutaway in Figure 3-5.  
Caution To ensure a positive ground attachment between the port adapter carrier and the VIP2  
motherboard and port adapter slot, and to ensure that the connectors at the rear of the port adapter  
and slot mate properly, position the carrier between the upper and lower slot edges, as shown in  
Figure 3-5.  
Step 4  
Carefully slide the new port adapter into the port adapter slot until the connector on the  
port adapter is completely seated in the connector on the motherboard. (See Figure 3-6.)  
3-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 3-6  
Port Adapter Installed in a Port Adapter SlotPartial Port Adapter View  
Step 5  
Step 6  
Replace the screw in the rear of the port adapter slot. (See Figure 3-3 for its location.) Do  
not overtighten this screw.  
To reinstall the VIP2 in the system, follow the steps in the section “Installing a VIP2” in  
the configuration note Second-Generation Versatile Interface Processor (VIP2)  
Installation and Configuration, which shipped with your VIP2.  
Step 7  
If the interface cables have been disconnected, reconnect the interface cables to the port  
adapters.  
This completes the procedure for installing a port adapter on a VIP2. Proceed to Chapter 8,  
“Configuring the PA-E3 Interfaces,” for information on how to configure your port adapter  
interfaces.  
VIP2 and the PA-E3 3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
3-8  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 4  
Catalyst RSM/VIP2 and the PA-E3  
This chapter provides information on the PA-E3 serial port adapter and its use on the  
Catalyst RSM/VIP2 in the Catalyst 5000 family switches. This chapter contains the following  
sections:  
Overview, page 4-1  
Removing a Port Adapter, page 4-3  
Installing a Port Adapter, page 4-4  
Overview  
The PA-E3 is used on the Catalyst RSM/VIP2 in the Catalyst 5000 family switches and can be  
installed in either port adapter slot 0 or slot 1 on the Catalyst RSM/VIP2 motherboard.  
Note You can have up to three E3 serial interfaces on a Catalyst RSM/VIP2 motherboard. Cisco  
recommends a configuration of one PA-E3 (with one E3 serial interface) and one PA-2E3 (with two  
serial interfaces) for a total of three E3 serial interfaces.  
Figure 4-1 shows two one-port PA-E3 port adapters installed in port adapter slot 0 and slot 1, on a  
Catalyst RSM/VIP2-40.  
Catalyst RSM/VIP2 and the PA-E3 4-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overview  
Figure 4-1  
Catalyst RSM/VIP2-40 with One-Port PA-E3 Port Adapters in Port Adapter  
Slots 0 and 1  
Standoff  
mounting  
hole  
Ribbon cables  
Backplane  
bus connector  
Standoff  
mounting  
holes  
Standoff  
mounting  
holes  
Port adapter  
securing screw  
Port adapter  
securing screw  
PA-E3 in port  
adapter slot 0  
PA-E3 in port  
adapter slot 1  
E3 SERIAL  
T3 SERIAL  
RCLK FERF RL  
RCLK FERF RL  
ENABLED  
RCVR  
ENABLED  
RCVR  
XMTR  
XMTR  
LL  
LL  
AIS  
AIS  
OOF  
OOF  
Port adapter  
handles not  
shown  
Note Port adapters have a handle attached, but this handle is not shown in the figure to allow a full  
view of detail on each port adapter’s faceplate.  
Depending on the circumstances, you might need to install a new port adapter on a  
Catalyst RSM/VIP2 motherboard or replace a failed port adapter in the field. In either case, you need  
the following items:  
Number 1 Phillips screwdriver  
Antistatic mat on which you can place the removed interface processor  
Antistatic container in which you can place a failed port adapter for shipment back to the factory  
Caution To prevent system problems, do not remove port adapters from the Catalyst RSM/VIP2  
motherboard or attempt to install other port adapters on the Catalyst RSM/VIP2 motherboard while  
the system is operating. To install or replace port adapters, first remove the Catalyst RSM/VIP2 from  
its slot.  
Note Each port adapter circuit board is mounted to a metal carrier and is sensitive to ESD damage.  
The following procedures should be performed by a Cisco-certified service provider only. The  
Catalyst RSM/VIP2 supports online insertion and removal (OIR), but individual port adapters do  
not. To replace port adapters, you must first remove the Catalyst RSM/VIP2 from the chassis and  
then install or replace port adapters as required. If a blank port adapter is installed on the  
Catalyst RSM/VIP2 in which you want to install a new port adapter, you must first remove the  
Catalyst RSM/VIP2 from the chassis and then remove the blank port adapter.  
4-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
When only one port adapter is installed on a Catalyst RSM/VIP2, a blank port adapter must fill the  
empty slot to conform to electromagnetic interference (EMI) emissions requirements and to allow  
air to flow through the chassis properly. If you plan to install a new port adapter, you must first  
remove the blank port adapter.  
Removing a Port Adapter  
The following is the standard procedure for removing any type of port adapter on the  
Catalyst RSM/VIP2:  
Step 1  
Attach an antistatic wrist strap between you and an unfinished chassis surface.  
Note If you want to install a new port adapter on a Catalyst RSM/VIP2 with a single port  
adapter, you must first remove the blank port adapter from the port adapter slot in which  
you want to install the new port adapter.  
Step 2  
Step 3  
For a new port adapter installation or a port adapter replacement, disconnect any interface  
cables from the ports on the front of the port adapter, although this is not required. You  
can remove a Catalyst RSM/VIP2 with cables attached; however, we do not recommend  
this action.  
To remove the Catalyst RSM/VIP2 from the chassis, follow the steps in the Route Switch  
Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note (Document  
Number 78-4780-01), which shipped with your Catalyst RSM/VIP2.  
Step 4  
Step 5  
Place the removed Catalyst RSM/VIP2 on an antistatic mat.  
Locate the screw at the rear of the port adapter (or blank port adapter) to be replaced.  
(See Figure 4-2.) This screw secures the port adapter (or blank port adapter) to its slot.  
Figure 4-2  
Location of Port Adapter ScrewPartial Port Adapter View  
Screw  
Step 6  
Step 7  
Remove the screw that secures the port adapter (or blank port adapter).  
With the screw removed, grasp the handle on the front of the port adapter (or blank  
port adapter) and carefully pull it out of its slot, away from the edge connector at the rear  
of the slot. (See Figure 4-3.)  
Catalyst RSM/VIP2 and the PA-E3 4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 4-3  
Pulling a Port Adapter Out of a SlotPartial Port Adapter View  
Step 8  
If you removed a port adapter, place it in an antistatic container for safe storage or  
shipment back to the factory. If you removed a blank port adapter, no special handling is  
required; however, store the blank port adapter for potential future use.  
This completes the procedure for removing a new port adapter on a Catalyst RSM/VIP2.  
Installing a Port Adapter  
The following is the standard procedure for replacing a port adapter on the Catalyst RSM/VIP2:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Remove the new port adapter from its antistatic container and position it at the opening  
of the slot.  
Step 3  
Carefully align the port adapter carrier between the upper and the lower edges of the port  
adapter slot, as shown in Figure 4-4.  
4-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 4-4  
Aligning a Port Adapter in a Port Adapter Slot  
Carrier  
Upper edge  
Lower edge  
Caution To prevent jamming the carrier between the upper and lower edges of the port adapter slot  
and to ensure that the edge connector at the rear of the port adapter mates with the connector at the  
rear of the port adapter slot, make certain that the leading edges of the carrier are between the upper  
and lower slot edges, as shown in the cutaway in Figure 4-5.  
Caution To ensure a positive ground attachment between the port adapter carrier and the  
Catalyst RSM/VIP2 motherboard and port adapter slot, and to ensure that the connectors at the rear  
of the port adapter and slot mate properly, position the carrier between the upper and lower slot  
edges, as shown in Figure 4-5.  
Step 4  
Carefully slide the new port adapter into the port adapter slot until the connector on the  
port adapter is completely seated in the connector on the motherboard. (See Figure 4-5.)  
Catalyst RSM/VIP2 and the PA-E3 4-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 4-5  
Port Adapter Installed in a Port Adapter SlotPartial Port Adapter View  
Step 5  
Step 6  
Replace the screw in the rear of the port adapter slot. (See Figure 4-2 for its location.) Do  
not overtighten this screw.  
To reinstall the Catalyst RSM/VIP2 in the system, follow the steps in the Route Switch  
Module Catalyst VIP2-15 and VIP2-40 Installation and Configuration Note (Document  
Number 78-4780-01), which shipped with your Catalyst RSM/VIP2.  
Step 7  
If the interface cables have been disconnected, reconnect the interface cables to the port  
adapters.  
This completes the procedure for installing a port adapter on a Catalyst RSM/VIP2. Proceed to  
Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your port  
adapter interfaces.  
4-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 5  
Cisco 7200 Series and the PA-E3  
This chapter provides information on the PA-E3 serial port adapter and its use in Cisco 7200 series  
routers. This chapter contains the following sections:  
Overview, page 5-1  
Removing a Port Adapter, page 5-2  
Installing a Port Adapter, page 5-3  
Overview  
The PA-E3 can be installed in any available port adapter slot in Cisco 7200 series routers (which  
consist of the two-slot Cisco 7202, four-slot Cisco 7204 and Cisco 7204VXR, and the six-slot  
Cisco 7206 and Cisco 7206VXR). Figure 5-1 shows a one-port PA-E3 installed in port adapter slot 3  
of a Cisco 7206.  
Figure 5-1  
Cisco 7206 with a PA-E3 in Port Adapter Slot 3  
TOKEN RING  
FAST ETHERNET  
E3 SERIAL  
RCLK FERF RL  
RCVR  
XMTR  
ENABLED  
LL  
AIS  
OOF  
PA-E3  
port  
ETHERNET-10BFL  
FAST SERIAL  
EN  
TX  
RX  
RX  
TX  
RX  
T
RX  
TX  
RX  
4
1
0
adapter  
FAST ETHERNET INPUT/OUTPUT CONTROLLER  
Depending on your circumstances, you might need to install a new port adapter in a Cisco 7200  
series router or replace a failed port adapter in the field. In either case, no tools are necessary; all port  
adapters available for the Cisco 7200 series connect directly to the router midplane and are locked  
into position by a port adapter lever. When removing and replacing a port adapter, you need an  
antistatic mat onto which you can place a removed port adapter and an antistatic container into which  
you can place a failed port adapter for shipment back to the factory.  
Cisco 7200 Series and the PA-E3 5-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
Note The Cisco 7200 series routers support online insertion and removal(OIR); therefore, you do  
not have to power down the Cisco 7200 series routers when removing and replacing a port adapter.  
When a port adapter slot is not in use, a blank port adapter must fill the empty slot to allow the router  
to conform to EMI emissions requirements and to allow proper airflow across the port adapters. If  
you plan to install a new port adapter in a slot that is not in use, you must first remove a blank port  
adapter.  
Removing a Port Adapter  
Following is the procedure for removing a port adapter from a Cisco 7200 series router:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Place the port adapter lever for the desired port adapter slot in the unlocked position. The  
port adapter lever remains in the unlocked position. (See Figure 5-2.)  
Figure 5-2  
Placing the Port Adapter Lever in the Unlocked PositionCisco 7206 Shown  
TOKEN RING  
FAST ETHERNET  
ETHERNET 10BT  
FAST SERIAL  
FAST ETHERNET INPUT/OUTPUT CONTROLLER  
Port adapter  
handle  
Port adapter  
Note: This adapter removal  
applies to any port or service  
adapter.  
lever (unlocked  
position)  
Step 3  
Grasp the handle on the port adapter and pull the port adapter from the midplane, about  
halfway out of its slot. If you are removing a blank port adapter, pull the blank  
port adapter completely out of the chassis slot.  
Note As you disengage the port adapter from the router midplane, OIR administratively  
shuts down all active interfaces on the port adapter.  
Step 4  
Step 5  
With the port adapter halfway out of the slot, disconnect all cables from the port adapter.  
After disconnecting the cables, pull the port adapter from its chassis slot.  
5-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter’s  
components or connector pins. (See Figure 5-3.)  
Figure 5-3  
Handling a Port Adapter  
Metal carrier  
Printed circuit board  
Step 6  
Place the port adapter on an antistatic surface with its components facing upward, or in a  
static shielding bag. If the port adapter will be returned to the factory, immediately place  
it in a static shielding bag.  
This completes the procedure for removing a port adapter from a Cisco 7200 series router.  
Installing a Port Adapter  
Following is the procedure for installing a new port adapter in a Cisco 7200 series router:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Remove the new port adapter from its antistatic container and position it at the opening  
of the slot. (See Figure 5-4.)  
Step 3  
Step 4  
Use both hands to grasp the port adapter by its metal carrier edges and position the port  
adapter so that its components face downward. (See Figure 5-3.)  
Align the left and the right edge of the port adapter metal carrier between the guides in  
the port adapter slot. (See Figure 5-4.)  
Figure 5-4  
Aligning the Port Adapter Metal Carrier Between the Slot  
GuidesCisco 7206 Shown  
TOKEN RING  
Slot  
guide  
FAST ETHERNET  
ETHERNET 10BT  
Note: This adapter alignment  
applies to any port or service  
adapter.  
Cisco 7200 Series and the PA-E3 5-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Step 5  
With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into  
the slot.  
Caution Do not slide the port adapter all the way into the slot until you have connected all required cables.  
Trying to do so disrupts normal operation of the router.  
Step 6  
Step 7  
With the port adapter halfway in the slot, connect all required cables to the port adapter.  
After connecting all required cables, carefully slide the port adapter all the way into the  
slot until the port adapter is seated in the router midplane.  
Step 8  
After seating the port adapter in the router midplane, move the port adapter lever to the  
locked position. Figure 5-5 shows the port adapter lever in the locked position.  
Note If the port adapter lever does not move to the locked position, the port adapter is  
not completely seated in the midplane. Carefully pull the port adapter halfway out of the  
slot, reinsert it, and move the port adapter lever to the locked position.  
Figure 5-5  
Placing the Port Adapter Lever in the Locked PositionCisco 7206 Shown  
TOKEN RING  
FAST ETHERNET  
ETHERNET 10BT  
FAST SERIAL  
FAST ETHERNET INPUT/OUTPUT CONTROLLER  
Port adapter  
handle  
Port adapter  
lever (locked  
position)  
Note: This adapter installation  
applies to any port or service  
adapter.  
This completes the procedure for installing a new port adapter in a Cisco 7200 series router. Proceed  
to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your  
port adapter interfaces.  
5-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 6  
Cisco uBR7200 Series and the PA-E3  
This chapter provides information on the PA-E3 serial port adapter and its use in Cisco uBR7200  
series universal broadband routers. This chapter includes the following sections:  
Overview, page 6-1  
Removing a Port Adapter, page 6-2  
Installing a Port Adapter, page 6-4  
Overview  
The PA-E3 can be installed in any of the available port adapter slots in Cisco uBR7200 series routers.  
Figure 6-1 shows a PA-E3 installed in port adapter slot 2 of a Cisco uBR7200 series router.  
Figure 6-1  
Cisco uBR7200 Series with a PA-E3 Port Adapter in Port Adapter Slot 2  
PA-E3  
E3 SERIAL  
RRCLKFERFFRRLL  
ENABLED  
port adapter  
LL  
AAIISS  
OOOF  
Depending on the circumstances, you might need to install a new port adapter or replace a failed port  
adapter in a Cisco uBR7200 series router. In either case, no tools are necessary; all port adapters  
available for the Cisco uBR7200 series routers connect directly to the router midplane and are locked  
into position by a port adapter retention clip (Cisco uBR7246) or lever (Cisco uBR7223). When  
removing and replacing a port adapter, you need an antistatic mat onto which you can place a  
removed port adapter and an antistatic container into which you can place a failed port adapter for  
shipment back to the factory.  
Cisco uBR7200 Series and the PA-E3 6-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
Note The Cisco uBR7200 series routers support online Insertion and Removal (OIR); therefore,  
you do not have to power down the router when removing and replacing a PA-E3.  
When a port adapter slot is not in use, blank port adapters must fill empty slots to allow the router to  
conform to EMI emissions requirements and to allow proper airflow across the port adapters. If you  
plan to install a new port adapter in a slot that is not in use, you must first remove the blank  
port adapter.  
Removing a Port Adapter  
Following is the procedure for removing a port adapter from a Cisco uBR7200 series router:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Unlock the port adapter retaining mechanism.  
For a Cisco uBR7246, place the port adapter retention clip for the desired port adapter  
slot in the unlocked position. The retention clip remains in the unlocked position. (See  
Figure 6-2.)  
Figure 6-2  
Placing the Port Adapter Retention Clip in the Unlocked  
PositionCisco uBR7246 Shown  
Port adapters  
Port adapter  
retention clip in  
unlocked position  
6-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
For a Cisco uBR7223, place the port adapter lever in the unlocked position.  
(See Figure 6-3.)  
Figure 6-3  
Placing the Port Adapter Lever in the Unlocked  
PositionCisco uBR7223 Shown  
Port adapters  
Port adapter  
lever in unlocked  
position  
Step 3  
Grasp the handle on the port adapter and pull the port adapter from the router midplane,  
about halfway out of its slot. If you are removing a blank port adapter, pull the blank  
port adapter completely out of the chassis slot.  
Note As you disengage the port adapter from the midplane, OIR administratively shuts  
down all active interfaces on the port adapter.  
Step 4  
Step 5  
With the port adapter halfway out of the slot, disconnect all cables from the port adapter.  
After disconnecting the cables, pull the port adapter from its chassis slot.  
Caution Always handle the port adapter by the carrier edges and handle; never touch the  
port adapter’s components or connector pins. (See Figure 6-4.)  
Figure 6-4  
Handling a Port Adapter  
Metal carrier  
Printed circuit board  
Cisco uBR7200 Series and the PA-E3 6-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Step 6  
Place the port adapter on an antistatic surface with its components facing upward, or in a  
static shielding bag. If the port adapter will be returned to the factory, immediately place  
it in a static shielding bag.  
This completes the procedure for removing a port adapter from a Cisco uBR7200 series router.  
Installing a Port Adapter  
Following is the procedure for installing a port adapter in a Cisco uBR7200 series router:  
Step 1  
Step 2  
Attach an ESD-preventive wrist strap between you and an unfinished chassis surface.  
Use both hands to grasp the port adapter by its metal carrier edges and position the  
port adapter so that its components are downward. (See Figure 6-4.)  
Step 3  
Align the left and the right edge of the port adapter metal carrier between the guides in  
the port adapter slot. (See Figure 6-5.)  
Figure 6-5  
Aligning the Port Adapter Metal Carrier Between the Slot Guides  
Metal carrier  
Inside  
slot guide  
PC board  
Step 4  
With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into  
the slot.  
Caution Do not slide the port adapter all the way into the slot until you have connected all required  
cables. Trying to do so disrupts normal operation of the router.  
Step 5  
Step 6  
With the port adapter halfway in the slot, connect all required cables to the port adapter.  
After connecting the cables, carefully slide the port adapter all the way into the slot until  
the port adapter is seated in the router midplane.  
Step 7  
Secure the port adapter:  
For a Cisco uBR7246, slide the port adapter retention clip up to the locked position.  
See Figure 6-6.  
Note If the retention clip does not slide up to the locked position, the port adapter is not  
completely seated in the midplane. Carefully pull the port adapter halfway out of the slot,  
reinsert it, and slide the retention clip up to the locked position.  
6-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 6-6  
Placing the Port Adapter Retention Clip in the Locked  
PositionCisco uBR7246 Shown  
Port adapters  
Port adapter  
retention clip in  
locked position  
For a Cisco uBR7223, place the port adapter lever in the locked position. (See  
Figure 6-7.)  
Figure 6-7  
Placing the Port Adapter Lever in the Locked  
PositionCisco uBR7223 Shown  
Port adapters  
Port adapter  
lever in locked  
position  
Note If the port adapter lever does not move to the locked position, the port adapter is  
not completely seated in the midplane. Carefully pull the port adapter halfway out of the  
slot, reinsert it, and move the port adapter lever to the locked position.  
This completes the procedure for installing a port adapter in a Cisco uBR7200 series router. Proceed  
to Chapter 8, “Configuring the PA-E3 Interfaces,” for information on how to configure your  
port adapter interfaces.  
Cisco uBR7200 Series and the PA-E3 6-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
6-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 7  
Cisco 7100 Series and the PA-E3  
This chapter provides information on the PA-E3 serial port adapter and its use in the Cisco 7100  
series routers. This chapter contains the following sections:  
Installation Overview, page 7-1  
Removing a Port Adapter, page 7-2  
Installing a Port Adapter, page 7-3  
Installation Overview  
The PA-E3 can be installed in port adapter slot 3 in Cisco 7120 series routers and in port adapter slot  
4 in Cisco 7140 series routers. Figure 7-1 shows port adapter slot 3 of a Cisco 7120 series router.  
Figure 7-2 shows port adapter slot 4 of a Cisco 7140 series router.  
Figure 7-1  
Cisco 7120 Series Router—Port Adapter Slot 3 Location  
Locked  
Unlocked  
ESD plug  
Slot 3  
SLOT  
0
SLOT  
1
PWR  
ACT ACT  
LNK LNK  
0
2
5
SYS  
RDY  
0
1
FE  
0
/
0
FE  
0
/
1
CONS  
AUX  
E3  
TX  
RX  
I
RX  
EN  
CEL CAR ALM  
7120  
-
AE3  
Cisco 7100 Series and the PA-E3 7-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Removing a Port Adapter  
Figure 7-2  
Cisco 7140 Series Router—Port Adapter Slot 4 Location  
Locked  
Unlocked  
ESD plug  
Slot 4  
SLOT  
0
SLOT  
1
PWR  
ACT ACT  
LNK LNK  
0
2
5
SYS  
RDY  
0
1
FE  
0
/
0
FE  
RX  
0
/
1
CONS  
AUX  
155  
-
MM  
155  
-
MM  
TX  
RX  
RX  
TX  
I
RX  
EN  
EN  
CEL CAR ALM  
CEL CAR ALM  
7140  
-
2MM3  
Depending on your circumstances, you might need to install a new port adapter in a Cisco 7100  
series router or replace a failed port adapter in the field. All port adapters available for the Cisco 7100  
series connect directly to the router and are locked into position by a locking tab with two screws  
(see Figure 7-1 or Figure 7-2). You need a number 2 Phillips screwdriver to loosen the screws.  
Note Cisco 7100 series routers support online insertion and removal (OIR); therefore, you do not  
have to power down the router when removing and replacing a port adapter.  
When a port adapter slot is not in use, a blank port adapter must fill the empty slot to allow the router  
to conform to EMI emissions requirements and to allow proper airflow across the port adapters. If  
you plan to install a new port adapter in a slot that is not in use, you must first remove a blank  
port adapter.  
Removing a Port Adapter  
Follow these steps to remove a port adapter from a Cisco 7100 series router:  
Step 1  
Step 2  
Step 3  
Attach an ESD-preventive wrist strap between you and the chassis. (See Figure 7-1 or  
Figure 7-2 for the location of the ESD plug.)  
Use a number 2 Phillips screwdriver to loosen the screws on the locking tab; then slide  
the tab down to the unlocked position. (See Figure 7-1 or Figure 7-2.)  
Grasp the handle on the port adapter and pull the port adapter from the router, about  
halfway out of its slot. If you are removing a blank port adapter, pull the blank port  
adapter completely out of the chassis slot.  
Note As you disengage the port adapter from the router, OIR administratively shuts  
down all active interfaces on the port adapter.  
Step 4  
Step 5  
With the port adapter halfway out of the slot, disconnect all cables from the port adapter.  
After disconnecting the cables, pull the port adapter from its chassis slot.  
Caution Always handle the port adapter by the carrier edges and handle; never touch the port adapter’s  
components or connector pins. (See Figure 7-3.)  
7-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 7-3  
Handling a Port Adapter  
Metal carrier  
Printed circuit board  
Step 6  
Step 7  
Place the port adapter on an antistatic surface with its components facing upward, or in a  
static shielding bag. If the port adapter will be returned to the factory, immediately place  
it in a static shielding bag.  
Install a blank port adapter or replacement port adapter to maintain proper flow of cooling  
air across the internal components. For procedures on how to install a port adapter, see  
the next section, “Installing a Port Adapter”.  
Note The blank port adapter is available from Cisco Systems as a spare. The blank  
port adapter product number is MAS-7100-PABLANK.  
This completes the procedure for removing a port adapter from a Cisco 7100 series router.  
Installing a Port Adapter  
Follow these steps to install a new port adapter in a Cisco 7100 series router:  
Step 1  
Attach an ESD-preventive wrist strap between you and the chassis. (See Figure 7-1 for  
the location of the ESD plug.)  
Step 2  
Ensure that the locking tab is down in the unlocked position. If it is locked, use a  
number 2 Phillips to loosen the screws; then slide the tab down to the unlocked position.  
(See Figure 7-1.)  
Step 3  
Step 4  
Step 5  
Step 6  
Remove the new port adapter from its antistatic container and position it at the opening  
of the slot.  
Use both hands to grasp the port adapter by its metal carrier edges, and position the port  
adapter so that its components face downward. (See Figure 7-3.)  
Align the left and the right edge of the port adapter metal carrier between the guides in  
the port adapter slot. (See Figure 7-4.)  
With the metal carrier aligned in the slot guides, gently slide the port adapter halfway into  
the slot.  
Caution Do not slide the port adapter all the way into the slot until you have connected all required cables.  
Trying to do so disrupts normal operation of the router.  
Cisco 7100 Series and the PA-E3 7-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing a Port Adapter  
Figure 7-4  
Aligning the Single-Width Port Adapter Between the Slot Guides  
Guides  
I
RCVR  
XMTR  
RCLK  
AIS  
FERF  
OOF  
FE  
EN  
RL  
0
/
LL  
Step 7  
Step 8  
With the port adapter halfway in the slot, connect all required cables to the port adapter.  
After connecting all required cables, carefully slide the port adapter all the way into the  
slot until the port adapter is seated in the router.  
Step 9  
After seating the port adapter in the router, slide the locking tab up to the locked position  
and tighten the screws. (Figure 7-1 or Figure 7-2 shows the locking tab in the locked  
position.)  
Note If the port adapter lever is not in the locked position, the port adapter is not  
completely seated in the router. Carefully pull the port adapter halfway out of the slot,  
reinsert it, and move the port adapter lever to the locked position.  
This completes the procedure for installing a new port adapter in a Cisco 7100 series router. Proceed  
to Chapter 8, “Configuring the PA-E3 Interfaces,” to connect the necessary cables to your port  
adapter.  
7-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C H A P T E R 8  
Configuring the PA-E3 Interfaces  
To continue your PA-E3 serial port adapter installation, you must configure the E3 interfaces. The  
instructions that follow apply to all supported platforms. Minor differences between the platforms  
are noted. This chapter contains the following sections:  
Using the EXEC Command Interpreter, page 8-1  
Identifying Port Adapter Slot and PA-E3 Interface Port Numbers, page 8-2  
Performing a Basic Configuration, page 8-7  
Configuration Example, page 8-8  
Customizing the PA-E3, page 8-8  
Configuring Cyclic Redundancy Checks, page 8-10  
Checking the Configuration, page 8-11  
If you installed a new PA-E3 or if you want to change the configuration of an existing interface, you  
must enter configuration mode using the configure command. If you replaced a PA-E3 that was  
previously configured, the system recognizes the new PA-E3 interfaces and brings each of them up  
in their existing configuration.  
After you verify that the new PA-E3 is installed correctly (the enabled LED goes on), use the  
privileged-level configure command to configure the new interfaces. You will need the following  
information for your configuration:  
Protocols you plan to route on each new interface  
Internet Protocol (IP) addresses if you are configuring the interfaces for IP routing  
Plan to use bridging or not on the new interfaces  
Timing source for each new interface and clock speeds for external timing  
For a summary of the configuration options available and instructions for configuring interfaces on  
the PA-E3, refer to the appropriate configuration publications listed in the “Related Documentation”  
section on page vi.  
Using the EXEC Command Interpreter  
You modify the configuration of your router through the software command interpreter called the  
EXEC (also called enable mode). You must enter the privileged level of the EXEC command  
interpreter with the enable command before you can use the configure command to configure a new  
interface or to change the existing configuration of an interface. The system prompts you for a  
password if one is set.  
Configuring the PA-E3 Interfaces 8-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Identifying Port Adapter Slot and PA-E3 Interface Port Numbers  
The system prompt for the privileged level ends with a pound sign (#) instead of an angle bracket  
(>). At the console terminal, use the following procedure to enter the privileged level:  
Step 1  
At the user-level EXEC prompt, enter the enable command. The EXEC prompts you for  
a privileged-level password as follows:  
Router> enable  
Password:  
Step 2  
Step 3  
Enter the password (the password is case-sensitive). For security purposes, the password  
is not displayed.  
When you enter the correct password, the system displays the privileged-level system  
prompt (#):  
Router#  
Proceed to the following section to configure the new interfaces.  
Identifying Port Adapter Slot and PA-E3 Interface Port Numbers  
This section describes how to identify port adapter slot and PA-E3 interface port numbers for  
Cisco 7200 series routers, Cisco 7100 series routers, Cisco uBR7200 series routers, and the VIP2.  
You can identify interface ports by physically checking the port location on the back of the router or  
by using software commands to display information about a specific interface or all interfaces in the  
router.  
The PA-E3 can be installed in the following slots on the hardware platforms described in this  
document:  
VIP2—Port adapter slot 0 and slot 1  
Catalyst RSM/VIP2—Port adapter slot 0 and slot 1  
Cisco 7100 series routers—Port adapter slot 3 in a Cisco 7120 series router and port adapter  
slot 4 in a Cisco 7140 series router  
Cisco 7200 series routers—Port adapter slot 1 and slot 2 in a Cisco 7202; port adapter slot 1  
through slot 4 in a Cisco 7204 and Cisco 7204VXR; port adapter slot 1 through slot 6 in a  
Cisco 7206 and Cisco 7206VXR  
Cisco uBR7200 series—Port adapter slot 1 and slot 2 in a Cisco uBR7246 and port adapter slot 1  
in a Cisco uBR7223  
Port adapters have a handle attached, but this handle is occasionally not shown in this document to  
allow a full view of detail on the port adapter’s faceplate.  
Cisco 7200 Series and Cisco uBR7200 Series Ports  
Physical port addresses specify the actual physical location of each interface port on a Cisco 7200  
series router (see Figure 8-1) or a Cisco uBR7200 series router (see Figure 8-2). This address is  
composed of a two-part number in the format port adapter slot number/interface port number, as  
follows:  
The first number identifies the chassis slot in which the PA-E3 is installed.  
The second number identifies the interface port on each PA-E3; the interface port is always  
numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3.  
8-2  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cisco 7200 Series and Cisco uBR7200 Series Ports  
Interface ports maintain the same address regardless of whether other port adapters are installed or  
removed from the slot. However, when you move a port adapter to a different slot, the first number  
in the address changes to reflect the new chassis slot number.  
In Cisco 7200 series routers, port adapter slots are numbered from the lower left to the upper right,  
beginning with port adapter slot 1 and continuing through port adapter slot 2 for the Cisco 7202,  
slot 4 for the Cisco 7204 and Cisco 7204VXR, and slot 6 for the Cisco 7206 and Cisco 7206VXR.  
Port adapter slot 0 is reserved for the optional Fast Ethernet port on the I/O controller if present.  
Figure 8-1 shows the port adapter slots and interface ports of a Cisco 7206. The individual interface  
port numbers always begin with 0. The number of additional ports depends on the number of ports  
on a port adapter.  
Note The I/O controller is available with or without a Fast Ethernet port. You can install both I/O  
controller types in all Cisco 7200 series routers; however, when you install an I/O controller with a  
Fast Ethernet port in a Cisco 7202, the system software automatically disables the port.  
For example, the serial port on a one-port PA-E3 in port adapter slot 3 has the address 3/0.  
(See Figure 8-1.) If the PA-E3 is in port adapter slot 1, this same interface port is numbered 1/0. The  
serial ports on a two-port PA-2E3 in port adapter slot 3 have the addresses 3/0 and 3/1.  
Note The PA-E3 is considered a high-bandwidth port adapter; you must observe specific  
configuration guidelines. Refer to the publication Cisco 7200 Series Port Adapter Hardware  
Configuration Guidelines, which shipped with your Cisco 7200 series chassis and is also available  
on the Cisco Connection Documentation, Enterprise Series CD-ROM.  
Figure 8-1  
Cisco 7206 Serial Port Number Example  
TOKEN RING  
FAST ETHERNET  
E3 SERIAL  
RCLK FERF RL  
RCVR  
XMTR  
ENABLED  
LL  
AIS  
OOF  
ETHERNET-10BFL  
FAST SERIAL  
EN  
TX  
RX  
RX  
TX  
RX  
RX  
TX  
RX  
4
2
1
0
FAST ETHERNET INPUT/OUTPUT CONTROLLER  
PA-E3 port adapter  
(port number 3/0)  
Figure 8-2 shows the interface ports of a PA-E3 in slot 2 of a Cisco uBR7200 series router. The port  
adapter slots are numbered slot 1 and slot 2 for the Cisco uBR7246 and slot 1 for the Cisco uBR7223  
(slot 0 is always reserved for the Fast Ethernet port on the I/O controller if present). The individual  
interface port numbers always begin with 0. The number of additional ports depends on the number  
of ports on a port adapter. Port adapters can occupy any port adapter slot; there are no restrictions.  
For example, the serial port on a one-port PA-E3 in port adapter slot 1 has the address 1/0.  
(See Figure 8-2.) If the PA-E3 is in port adapter slot 2, this same interface port is numbered 2/0. The  
serial ports on a two-port PA-2E3 in port adapter slot 2 have the addresses 2/0 and 2/1.  
Configuring the PA-E3 Interfaces 8-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Identifying Port Adapter Slot and PA-E3 Interface Port Numbers  
Figure 8-2  
PA-E3 Interface Port Address ExampleCisco uBR7246 Shown  
PA-E3  
port adapter  
E3 SERIAL  
RRCLKFERRFFRRLL  
ENABLED  
(port number 1/0)  
LL  
AAIISS  
OOOF  
You can identify interface ports by physically checking the port adapter/interface port location on  
the back of the router or by using software commands to display information about a specific  
interface or all interfaces in the router.  
VIP2 Ports  
In the router, physical port addresses specify the actual physical location of each interface port on  
the router interface processor end. (See Figure 8-3.) Each address is composed of a three-part  
number in the format interface processor slot number/port adapter number/interface port number,  
as follows:  
The first number identifies the chassis slot in which the VIP2 is installed (as shown in the sample  
system in Figure 8-3).  
The second number identifies the physical port adapter slot on the VIP2, and is either 0 or 1.  
The third number identifies the interface port on each E3 serial port adapter, which is always  
numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3.  
Note Although the processor slots in the 7-slot Cisco 7000 and Cisco 7507 and 13-slot Cisco 7513  
are vertically oriented and the slots in the 5-slot Cisco 7010 and Cisco 7505 are horizontally  
oriented, all models use the same method for slot and port numbering.  
Interface ports on the VIP2 maintain the same address regardless of whether other interface  
processors are installed or removed. However, when you move a VIP2 to a different slot, the first  
number in the address changes to reflect the new chassis slot number.  
Figure 8-3 shows the port adapter slots and interface ports of a sample Cisco 7505 system. On the  
VIP2, the first port adapter slot number is always 0. The second port adapter slot number is always 1.  
The individual interface port numbers always begin with 0. The number of additional ports depends  
on the number of ports on a port adapter.  
For example, the serial port on a one-port PA-E3 in the first port adapter slot in chassis slot 3 is  
numbered 3/0/0. (See Figure 8-3.) If the PA-E3 is in port adapter slot 1, this same port is numbered  
3/1/0. The serial ports on a two-port PA-2E3 in the first port adapter slot in chassis slot 3 are  
numbered 3/0/0 and 3/0/1.  
Port adapters can occupy either port adapter slot; there are no restrictions.  
8-4  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Catalyst RSM/VIP2 Ports  
Figure 8-3  
Cisco 7505 Serial Port Number Example  
PA-E3 (port number 3/0/0)  
PA-E3 (port numbers 3/1/0)  
ROUTE SWITCH PROCESSOR  
EJECT  
CPU HALT RESET  
SLOT  
1
SLOT  
0
CONSOLE  
NORMAL  
E3 SERIAL  
E3 SERIAL  
RCLK FERF RL  
RCLK FERF RL  
Slot 3  
Slot 2  
Slot 1  
XMTR  
RCVR  
ENABLED  
XMTR  
RCVR  
ENABLED  
LL  
AIS  
OOF  
LL  
AIS  
OOF  
Interface  
processor  
slots  
Slot 0  
You can identify interface ports by physically checking the slot/port-adapter/interface port location  
on the back of the router or by using show commands to display information about a specific  
interface or all interfaces in the router.  
Catalyst RSM/VIP2 Ports  
In the Catalyst RSM/VIP2, each port adapter address is composed of a two-part number in the  
format port adapter number/interface port number, as follows:  
The first number identifies the physical port adapter slot on the Catalyst RSM/VIP2, and is either  
0 or 1.  
The second number identifies the interface port on each E3 serial port adapter, which is always  
numbered as interface 0 for the one-port PA-E3 and 0 or 1 for the two-port PA-2E3.  
Figure 8-4 shows the port adapters on a Catalyst RSM/VIP2 installed in a Catalyst 5509 switch. The  
first port adapter slot number is always 0. The second port adapter slot number is always 1. The  
individual interface port numbers always begin with 0. The number of additional ports depends on  
the number of ports on a port adapter.  
For example, the serial port on a one-port PA-E3 in the first port adapter slot is numbered 0/0. (See  
Figure 8-4.) If the PA-E3 is in port adapter slot 1, this same port is numbered 1/0. The serial ports  
on a two-port PA-2E3 in the first port adapter slot are numbered 0/0 and 0/1.  
Port adapters can occupy either port adapter slot; there are no restrictions.  
Configuring the PA-E3 Interfaces 8-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Identifying Port Adapter Slot and PA-E3 Interface Port Numbers  
Figure 8-4  
Serial Port Adapters in the Catalyst 5509  
WS-x5530  
100%  
FAN  
PS2  
PS1  
WS-U5531-FETX  
SYSTEM  
STATUS  
RESET  
ACTIVE  
PORT  
1
SLOT  
SLOT  
1
0
MDIX  
PORT 2  
1
2
MDIX  
10/100Mbps  
LINK  
10/100Mbps  
LINK  
SUPERVISOR ENGINE  
WS-x5530  
I
I
I
CONSOLE  
AUX  
PCMCIA  
Switch Load  
10/100 FAST ETHERCHANNEL  
100%  
FAN  
PS2  
PS1  
WS-U5531-FETX  
PORT  
SYSTEM  
STATUS  
RESET  
ACTIVE  
1
SLOT  
SLOT  
1
0
MDIX  
PORT 2  
MDIX  
10/100Mbps  
LINK  
10/100Mbps  
LINK  
SUPERVISOR ENGINE  
I
I
I
CONSOLE  
AUX  
PCMCIA  
Switch Load  
10/100 FAST ETHERCHANNEL  
3
4
STATUS  
FAST ETHERNET SWITCHING MODULE  
1
2
3
4
5
6
7
8
9
10  
STATUS  
11  
12  
FAST ETHERNET SWITCHING MODULE  
Versatile Interface Processor  
with port adapters  
E3 SERIAL  
ENABLED  
R
C
L
K
F
E
R
F
RL  
5
6
RCVR  
E3 SERIAL  
XMTR  
ENABLED  
R
C
L
K
RCVR  
XMTR  
E3  
LL  
AIS  
E3  
OOF  
LL  
AIS  
OOF  
Route Switch Module  
ROUTE SWITCH MODULE  
1
1
1
2
3
4
7
8
5
6
7
8
9
STATUS  
10  
11  
12  
FAST ETHERNET SWITCHING MODULE  
2
3
4
5
6
7
8
9
STATUS  
10  
11  
12  
FAST ETHERNET SWITCHING MODULE  
2
9
3
4
5
6
7
8
9
STATUS  
10  
11  
12  
FAST ETHERNET SWITCHING MODULE  
o
o
AC  
OK  
FAN  
OK  
OUTPUT  
FAIL  
AC  
OK  
FAN  
OK  
OUTPU
FAIL  
You can identify interface ports by physically checking the port-adapter/interface port location on  
the back of the router or by using show commands to display information about a specific interface  
or all interfaces in the router.  
Cisco 7100 Series Ports  
In the Cisco 7100 series routers, the slot number is the location in the chassis where the interface  
resides and the port number is the physical port. Interfaces in the Cisco IOS software are identified  
by a type, slot number, and port number. For example, serial 3/1 indicates port 1 on the serial  
port adapter in slot 3.  
Slots in the Cisco 7120 series routers are numbered as shown in Figure 8-5. The fixed LAN interface  
is slot 0, the fixed WAN interface is slot 1, and the modular port adapter interface is slot 3. Slots 2  
and 4 are not used on the Cisco 7120 series routers. Slot 5 is the service module.  
Figure 8-5  
Port Adapter Slot Numbering—Cisco 7120 Series  
Slot 5  
Slot 3  
SLOT  
0
SLOT  
1
PWR  
ACT ACT  
LNK LNK  
0
2
5
SYS  
RDY  
0
1
FE  
0
/
0
FE  
0
/
1
CONS  
AUX  
E3  
TX  
RX  
I
RX  
EN  
CEL CAR ALM  
7120  
-
AE3  
Slot 1  
Slot 0  
8-6  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performing a Basic Configuration  
Slots in the Cisco 7140 series routers are numbered as shown Figure 8-6. The fixed LAN interface  
is slot 0, the fixed WAN interfaces are slots 1 and 2, and the modular port adapter interface is slot 4.  
Slot 3 is not used. Slot 5 is the service module.  
Figure 8-6  
Port Adapter Slot Numbering—Cisco 7140 Series  
Slot 5  
Slot 4  
SLOT  
0
SLOT  
1
BOOT  
PWR  
ACT ACT  
LNK LNK  
SM-EC-DS  
RESET  
ERROR  
EN  
0
2
5
SYS  
RDY  
0
1
FE  
0
/
0
FE  
RX  
0
/
1
CONS  
AUX  
155  
-
MM  
155  
-
MM  
TX  
RX  
RX  
TX  
I
RX  
EN  
EN  
CEL CAR ALM  
CEL CAR ALM  
7140  
-
2MM3  
Slot 1  
Slot 0 Slot 2  
Performing a Basic Configuration  
The following steps are for a basic interface configuration for the PA-E3. Press the Return key after  
each step unless otherwise noted. At any time you can exit the privileged level and return to the user  
level by entering disable at the prompt:  
router# disable  
router>  
Step 1  
Step 2  
At the privileged-level prompt, enter configuration mode and specify that the console  
terminal is the source of the configuration subcommands:  
router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)#  
Specify the interface to configure:  
For Cisco 7100 series, Cisco 7200 series, or Cisco uBR7200 series routers, specify the  
interface to configure by entering the subcommand interface serial followed by the  
slot/port (port adapter slot number and interface port number). The example that  
follows is for the interface of the port adapter in slot 3:  
router(config)# interfaceserial 3/0  
For a VIP2, specify the interface to configure by entering the subcommand  
interface serial, followed by the slot/port-adapter/port (interface processor slot  
number, port adapter slot number, and interface port number). The example that  
follows is for the interface of the first port adapter on a VIP2 in interface processor slot  
1:  
router(config)# interfaceserial 1/0/0  
For a Catalyst RSM/VIP2, specify the interface to configure by entering the  
subcommand interface serial, followed by the port-adapter/port (port adapter slot  
number and interface port number). The example that follows is for the interface of  
the first port adapter on a Catalyst RSM/VIP2:  
router(config)# interfaceserial 0/0  
Configuring the PA-E3 Interfaces 8-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Example  
Step 3  
If IP routing is enabled on the system, change to interface configuration mode and use the  
ip address configuration subcommand to assign an IP address and subnet mask to the  
interface, as in the following example:  
router(config-if)# ip address 10.0.0.0 10.255.255.255  
Step 4  
Step 5  
In interface configuration mode, choose the internal clock source by entering the  
clock source configuration subcommand, as in the following example:  
router(config-if)# clock source internal  
Use the no form of this command to restore the default clock source, which is line.  
In interface configuration mode, change the shutdown state to up and enable the interface  
as follows:  
router(config-if)# no shutdown  
Step 6  
Step 7  
Configure additional interfaces as required.  
When you have included all of the configuration subcommands to complete the  
configuration, press Ctrl-Z to exit configuration mode.  
Step 8  
Write the new configuration to nonvolatile memory as follows:  
router# copy running-config startup-config  
[OK]  
router#  
To check the interface configuration using show commands, proceed to the “Using show Commands  
to Display Interface and System Information” section on page 8-12.  
Configuration Example  
The following example shows a typical configuration for the PA-E3 on a Cisco 7500 series router:  
router> enable  
router# configure terminal  
router(config)# interface serial  
router(config)# interface serial 1/0/0  
router(config)# ip address 1.1.1.10 255.255.255.0  
router(config-if)# clock source internal  
router(config-if)# no shutdown  
router(config-if)# ^Z  
Customizing the PA-E3  
You can customize the PA-E3. The features you can customize have default values that will probably  
suit your environment and need not be changed. However, you might need to enter configuration  
commands, depending on the requirements for your system configuration and the protocols you plan  
to route on the interface. Perform the tasks in the following sections if you need to customize the  
PA-E3.  
8-8  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the Bandwidth  
Setting the Bandwidth  
In interface configuration mode, reduce effective bandwidth (range of 22 to 34010 kilobits per  
second) by entering the dsu bandwidth configuration subcommand, as in the following example:  
router(config-if)# dsu bandwidth 16000  
Use the no form of this command to return to the default, 34010.  
Note The local port configuration must match the remote port configuration. For example, if you  
reduce the effective bandwidth to 16000 on the local port, you must do the same on the remote port.  
Defining the DSU Mode  
In interface configuration mode, define the DSU interoperability mode by entering the  
dsu mode [0 | 1] configuration subcommand, as in the following example:  
router(config-if)# dsu mode 1  
Use the no form of this command to return to the default, 0.  
Note The local port configuration must match the remote port configuration. For example, if you  
define the DSU interoperability mode as 1 on the local port, you must do the same on the remote  
port. You need to know what type of DSU is at the remote port to find out if it interoperates with the  
PA-E3. For E3 serial interfaces, specify mode 0 for connection from a PA-E3 to another PA-E3 or a  
Digital Link DSU (DL3100). Specify mode 1 for connection from a PA-E3 to a Kentrox DSU.  
Also refer to the “Interoperability Guidelines for PA-E3 DSUs” section on page 15 for information  
regarding DSU feature compatibilities.  
Defining Set Bit (National)  
In interface configuration mode, define set bit in G751 frame (national bit) by entering the  
national bit [0 | 1] configuration subcommand, as in the following example:  
router(config-if)# national bit 1  
Use the no form of this command to return to the default, which is 0.  
Enabling E3 Scrambling  
In interface configuration mode, enable E3 scrambling by entering the scramble configuration  
subcommand, as in the following example:  
router(config-if)# scramble  
Use the no form of this command to restore the default value, which is disabled.  
Note The local port configuration must match the remote port configuration. For example, if you  
enable scrambling on the local port, you must do the same on the remote port.  
Also refer to the “Interoperability Guidelines for PA-E3 DSUs” section on page 15 for information  
regarding DSU feature compatibilities.  
Configuring the PA-E3 Interfaces 8-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuring Cyclic Redundancy Checks  
Specifying E3 Framing  
In interface configuration mode, specify E3 framing by entering the framing {g751 | bypass}  
configuration subcommand, as in the following example:  
router(config-if)# framing g751  
Use the no form of this command to return to the default, which is G.751 framing.  
Note If you use the bypass option, scrambling must be set to the default, disabled; the DSU mode  
must be set to the default, 0; and the DSU bandwidth must be set to the default, 34010.  
Setting the Cable Length  
In interface configuration mode, set the cable length (0 to 450 feet), as in the following example:  
router(config-if)# cablelength 250  
Use the no form of this command to return to the default, which is 10 feet.  
Configuring Cyclic Redundancy Checks  
The PA-E3 uses a 16-bit cyclic redundancy check (CRC) by default; it also supports a 32-bit CRC.  
The CRC is an error-checking technique that uses a calculated numeric value to detect errors in  
transmitted data. The sender of a data frame divides the bits in the frame message by a predetermined  
number to calculate a remainder or frame check sequence (FCS). Before sending the frame, the  
sender appends the FCS value to the message so that the frame contents are exactly divisible by the  
predetermined number. The receiver divides the frame contents by the same predetermined number  
that the sender used to calculate the FCS. If the result is not 0, the receiver assumes that a  
transmission error occurred and sends a request to the sender to resend the frame.  
Note To enable a 32-bit CRC on an interface, follow Step 1 and Step 2 of the preceding procedure  
(enter configuration mode and specify the slot and port address of the PA-E3, and the interface port  
number for a VIP2), and then enter the command crc 32. Enter Ctrl-Z to exit from configuration  
mode.  
For a Cisco 7100 series, Cisco 7200 series, or Cisco uBR7200 series router, use the following  
example:  
router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)#  
router(config)# interface serial 3/0  
router(config-int)# crc 32  
Ctrl-z  
8-10  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
For a VIP2, use the following example:  
router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)#  
router(config)# interface serial 1/0/0  
router(config-if)# crc 32  
Ctrl-z  
For a Catalyst RSM/VIP2, use the following example:  
router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)#  
router(config)# interface serial 0/0  
router(config-if)# crc 32  
Ctrl-z  
To disable CRC-32 and return to the default CRC-16 setting, specify the slot and port address (and  
the interface port number for a VIP2) and use the no crc 32 command. For complete command  
descriptions and instructions, refer to the related software documentation.  
Note When enabling a 32-bit CRC on an interface, ensure that the remote device is also configured  
for a 32-bit CRC. Both the sender and the receiver must use the same CRC setting.  
To check the interface configuration using show commands, proceed to the following section,  
“Checking the Configuration.”  
Checking the Configuration  
After configuring the new interface, use the show commands to display the status of the new  
interface or all interfaces, the ping command to check connectivity, and the loopback command to  
verify the physical interface.  
Using show Commands to Verify Status  
Use show commands to verify that the new interfaces are configured and operating correctly:  
Step 1  
Step 2  
Step 3  
Use the show version command to display the system hardware configuration. Ensure  
that the list includes the new interfaces.  
Display all of the current port adapters and their interfaces with the show controllers  
command. Verify that the new PA-E3 appears in the correct slot.  
Specify one of the new interfaces as follows:  
show interfaces type slot/port command on Cisco 7100 series, Cisco 7200 series, and  
Cisco uBR7200 series routers  
show interfaces type slot/port-adapter/port on the VIP2  
show interfaces port-adapter/port on the Catalyst RSM/VIP2  
Verify that the first line of the display specifies the interface with the correct slot number  
and that the interface and line protocol are in the correct state: up or down.  
Configuring the PA-E3 Interfaces 8-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
Step 4  
Specify one of the new interfaces as follows:  
show interfaces port adapter type slot/port on Cisco 7100 series, Cisco 7200 series,  
and Cisco uBR7200 series routers  
show interfaces type slot/port adapter/interface command on the VIP2  
show interfaces port adapter/interface command on the Catalyst RSM/VIP2  
Verify that the first line of the display specifies the interface with the correct slot number  
and that the interface and line protocol are in the correct state: up or down.  
Step 5  
View the information that is specific to the serial interface hardware:  
For Cisco 7100, Cisco 7200 series and Cisco uBR7200 series routers, specify the new  
serial interface with the show controllers serial [port adapter slot number/interface  
port number] command, and verify that the first line of the display specifies the  
interface with the correct slot number.  
For a VIP2, specify information that is specific to the new serial interface with the  
show controllers serial [type slot/port adapter/interface] command, and verify that  
the first line of the display specifies the interface with the correct slot number.  
For a Catalyst RSM/VIP2, specify information that is specific to the new serial  
interface with the show controllers serial [port adapter/interface] command, and  
verify that the first line of the display specifies the interface with the correct slot  
number.  
Step 6  
Step 7  
Display the protocols configured for the entire system and for the specific interfaces with  
the show protocols command. If necessary, return to configuration mode to add or  
remove protocol routing on the system or on specific interfaces.  
Display the running configuration file with the show running-config command. Display  
the configuration stored in NVRAM using the show startup-config command. Verify  
that the configuration is accurate for the system and each interface.  
If the interface is down and you configured it as up, or if the displays indicate that the hardware is  
not functioning properly, ensure that the network interface is properly connected and terminated. If  
you still have problems bringing the interface up, ask a service representative for assistance.  
Using show Commands to Display Interface and System Information  
For Cisco 7100, Cisco 7200, or Cisco uBR7200 series routers, to display information about a  
specific interface, use the show interfaces command with the interface type and port address in the  
format show interfaces type slot/port.  
8-12  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using show Commands to Display Interface and System Information  
The following example of the show interfaces type slot/port command shows all of the information  
specific to the serial E3 port (interface port 0) in port adapter slot 2:  
router# show interfaces serial 2/0  
Serial2/0 is up, line protocol is up  
Hardware is M1T-E3 pa  
Internet address is 172.16.0.0/8  
MTU 4470 bytes, BW 34010 Kbit, DLY 200 usec, rely 255/255, load 1/255  
Encapsulation HDLC, loopback not set, keepalive not set  
Last input 00:00:05, output 00:00:46, output hang never  
Last clearing of "show interface" counters never  
Queueing strategy: fifo  
Output queue 0/40, 0 drops; input queue 0/75, 0 drops  
5 minute input rate 0 bits/sec, 0 packets/sec  
5 minute output rate 0 bits/sec, 0 packets/sec  
22 packets input, 7128 bytes, 0 no buffer  
Received 22 broadcasts, 0 runts, 0 giants  
0 parity  
6 input errors, 3 CRC, 0 frame, 0 overrun, 0 ignored, 3 abort  
22 packets output, 7348 bytes, 0 underruns  
0 output errors, 0 applique, 6 interface resets  
0 output buffer failures, 0 output buffers swapped out  
1 carrier transitions  
rxLOS inactive rxLOF inactive rxAIS inactive  
txAIS inactive txRAI inactive  
For a VIP2, the show interfaces type slot/port-adapter/port command displays status information  
(including the physical slot and port address) for the interfaces you specify. In this example, a  
one-port E3 serial port adapter-configured VIP2 is in chassis slot 1, in port adapter slot 0.  
router# show interfaces serial 1/0/0  
Serial1/0/0 is up, line protocol is up  
Hardware is cyBus Serial  
Internet address is 10.0.0.0/24  
MTU 4470 bytes, BW 45045 Kbit, DLY 200 usec, rely 255/255, load 1/255  
Encapsulation HDLC, loopback not set, keepalive not set  
Last input 2d22h, output 00:00:19, output hang never  
Last clearing of “show interface” counters 2d20h  
Queueing strategy: fifo  
Output queue 0/40, 0 drops; input queue 0/75, 0 drops  
5 minute input rate 0 bits/sec, 0 packets/sec  
5 minute output rate 0 bits/sec, 0 packets/sec  
0 packets input, 0 bytes, 0 no buffer  
Received 0 broadcasts, 0 runts, 0 giants, 0 parity  
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort  
4084 packets output, 1298712 bytes, 0 underruns  
0 output errors, 0 applique, 0 interface resets  
0 output buffer failures, 0 output buffers swapped out  
0 carrier transitions  
For a Catalyst RSM/VIP2, the show interfaces port-adapter/port command displays status  
information for the interfaces you specify. In this example, a one-port E3 serial port  
adapter-configured Catalyst RSM/VIP2 in port adapter slot 0.  
router# show interfaces serial 0/0  
Serial0/0 is up, line protocol is up  
Hardware is cyBus Serial  
Internet address is 10.0.0.0/24  
MTU 4470 bytes, BW 45045 Kbit, DLY 200 usec, rely 255/255, load 1/255  
Encapsulation HDLC, loopback not set, keepalive not set  
Last input 2d22h, output 00:00:19, output hang never  
Last clearing of “show interface” counters 2d20h  
Queueing strategy: fifo  
Configuring the PA-E3 Interfaces 8-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
Output queue 0/40, 0 drops; input queue 0/75, 0 drops  
5 minute input rate 0 bits/sec, 0 packets/sec  
5 minute output rate 0 bits/sec, 0 packets/sec  
0 packets input, 0 bytes, 0 no buffer  
Received 0 broadcasts, 0 runts, 0 giants, 0 parity  
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort  
4084 packets output, 1298712 bytes, 0 underruns  
0 output errors, 0 applique, 0 interface resets  
0 output buffer failures, 0 output buffers swapped out  
0 carrier transitions  
For Cisco 7100, Cisco 7200, and Cisco uBR7200 series routers, use the show controllers serial  
command, using arguments such as the slot and port number (slot/port), to display information that  
is specific to the serial interface hardware. Following is an example of the show controllers serial  
slot/port command that shows the serial port adapter installed on a Cisco 7200 series router in  
chassis slot 3:  
router# show controllers serial 3/0  
M1T-Serial: show controller:  
PAS unit 0, subunit 0, f/w version 1-23, rev ID 0x1, version 2  
idb = 0x608E3340, ds = 0x608E50C0, ssb=0x608E5A84  
Clock mux=0x35, ucmd_ctrl=0x8, port_status=0x25  
maxdgram=4474, bufpool=64Kb, 128 particles  
TM=down CA=up LC=down  
line state: up  
Serial DTE cable  
(Display text omitted.)  
For a VIP2, use the show controllers serial command, using arguments such as those that specify  
the slot, port adapter, and port numbers (slot/port-adapter/port), to display information that is  
specific to the serial interface hardware. Following is an example of the show controllers serial  
slot/port adapter/interface command that shows serial port 2/0/1 on a one-port PA-E3 installed on a  
VIP2 in chassis slot 1:  
router# show controllers serial 2/0/1  
Serial2/0/1  
Mx E3(2) HW Revision 0x2, FW Revision 2.42  
Framing is g751, Clock Source is Line, Bandwidth limit is 34010.  
National Bit is 0, International Bits are: 0 0  
DSU mode 0  
Data in current interval (421 seconds elapsed):  
0 Line Code Violations, 0 P-bit Coding Violation  
0 C-bit Coding Violation  
0 P-bit Err Secs, 0 P-bit Severely Err Secs  
0 Severely Err Framing Secs, 0 Unavailable Secs  
0 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs  
Total Data (last 1 15 minute intervals):  
4 Line Code Violations, 0 P-bit Coding Violation,  
0 C-bit Coding Violation,  
0 P-bit Err Secs, 0 P-bit Severely Err Secs,  
0 Severely Err Framing Secs, 0 Unavailable Secs,  
3 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs  
No alarms detected.  
(Display text omitted.)  
8-14  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using show Commands to Display Interface and System Information  
For a Catalyst RSM/VIP2, use the show controllers serial command, using arguments such as those  
that specify the port adapter and port numbers (port-adapter/port), to display information that is  
specific to the serial interface hardware. Following is an example of the show controllers serial  
port-adapter/interface command that shows serial port 0/1 on a one-port PA-E3 installed on a  
Catalyst RSM/VIP2:  
router# show controllers serial 0/1  
Serial0/1  
Mx E3(2) HW Revision 0x2, FW Revision 2.42  
Framing is g751, Clock Source is Line, Bandwidth limit is 34010.  
National Bit is 0, International Bits are: 0 0  
DSU mode 0  
Data in current interval (421 seconds elapsed):  
0 Line Code Violations, 0 P-bit Coding Violation  
0 C-bit Coding Violation  
0 P-bit Err Secs, 0 P-bit Severely Err Secs  
0 Severely Err Framing Secs, 0 Unavailable Secs  
0 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs  
Total Data (last 1 15 minute intervals):  
4 Line Code Violations, 0 P-bit Coding Violation,  
0 C-bit Coding Violation,  
0 P-bit Err Secs, 0 P-bit Severely Err Secs,  
0 Severely Err Framing Secs, 0 Unavailable Secs,  
3 Line Errored Secs, 0 C-bit Errored Secs, 0 C-bit Severely Errored Secs  
No alarms detected.  
(Display text omitted.)  
The show version (or show hardware) command displays the configuration of the system hardware  
(the number of each port adapter type installed), the software version, the names and sources of  
configuration files, and the boot images. Following is an example of the output from the  
show version command on a Cisco 7200 series router:  
router# show version  
Cisco Internetwork Operating System Software  
IOS (tm) 7200 Software (C7200-P-M), Version 11.1(16)CA  
Synced to mainline version: 11.1(10.5)  
Copyright (c) 1986-1997 by cisco Systems, Inc.  
Compiled Thu 22-May-97 14:40  
Image text-base: 0x600088F0, data-base: 0x604B6000  
ROM: System Bootstrap, Version 11.1(5) [mkamson 5], RELEASE SOFTWARE (fc1)  
ROM: 7200 Software (C7200-BOOT-M), Version 11.1(6), RELEASE SOFTWARE (fc1)  
byron uptime is 22 minutes  
System restarted by reload  
System image file is "paking/poet/c7200-p-mz", booted via tftp from 172.16.0.0  
cisco 7206 (NPE150) processor with 12288K/4096K bytes of memory.  
R4700 processor, Implementation 33, Revision 1.0 (512KB Level 2 Cache)  
Last reset from power-on  
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.  
4 Ethernet/IEEE 802.3 interfaces.  
1 Serial network interface.  
1 FDDI network interface.  
125K bytes of non-volatile configuration memory.  
1024K bytes of packet SRAM memory.  
4096K bytes of Flash internal SIMM (Sector size 256K).  
Configuration register is 0x2  
Configuring the PA-E3 Interfaces 8-15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
Following is an example of the show version command used with a Cisco 7500 series system:  
router# show version  
Cisco Internetwork Operating System Software  
IOS (tm) GS Software, Version 11.1(16)CA  
Synced to mainline version: 11.1(10.5)  
Copyright (c) 1986-1997 by cisco Systems, Inc.  
Compiled Thu 22-May-97 14:32  
Image text-base: 0x600108E0, data-base: 0x60A00000  
ROM: System Bootstrap, Version 5.3.2(3.2) [kmac 3.2], MAINTENANCE INTERIM SOFTWARE  
ROM: GS Software, Version 11.1(8)CA, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1)  
keats uptime is 22 minutes  
System restarted by reload  
System image file booted via tftp from 172.16.0.0  
Last reset from power-on  
G.703/E1 software, Version 1.0.  
G.703/JT2 software, Version 1.0.  
SuperLAT software (copyright 1990 by Meridian Technology Corp).  
Bridging software.  
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.  
TN3270 Emulation software (copyright 1994 by TGV Inc).  
Chassis Interface.  
3 VIP2 controllers (1 FastEthernet)(4 Ethernet)(1 Fddi)(2 E3).  
4 Ethernet/IEEE 802.3 interfaces.  
1 FastEthernet/IEEE 802.3 interface.  
2 Serial network interfaces.  
1 FDDI network interface.  
125K bytes of non-volatile configuration memory.  
8192K bytes of Flash internal SIMM (Sector size 256K).  
Configuration register is 0x2  
To determine which type of port adapter is installed in your system, use the show diag slot  
command. Specific port adapter information is displayed, as shown in the following example of a  
one-port PA-E3 in chassis slot 3 on a Cisco 7200 series router:  
router# show diag 3  
Slot 3:  
E3 PA port adapter, 1 ports  
Port adapter is analyzed  
Port adapter insertion time 01:04:31 ago  
Hardware revision 1.0  
Board revision UNKNOWN  
Serial number  
Test history  
3710903  
0x0  
Part number  
RMA number  
73-1801-03  
00-00-00  
EEPROM format version 1  
EEPROM contents (hex):  
0x20: 01 71 01 00 00 38 9F B7 49 07 09 03 00 00 00 00  
0x30: 06 00 00 00 FF FF FF 00 FF FF FF FF FF FF FF FF  
8-16  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using show Commands to Display Interface and System Information  
To determine which type of port adapter is installed on a VIP2 in your system, use the show diag slot  
command. Specific port adapter information is displayed, as shown in the following example of a  
one-port PA-E3 in chassis slot 2:  
router# show diag 2  
Slot 2:  
Physical slot 2, ~physical slot 0xD, logical slot 2, CBus 0  
Microcode Status 0x4  
Master Enable, LED, WCS Loaded  
Board is analyzed  
Pending I/O Status: None  
EEPROM format version 1  
VIP2 controller, HW rev 2.4, board revision D0  
Serial number: 04371939 Part number: 73-1684-03  
Test history: 0x00  
Flags: cisco 7500  
RMA number: 00-00-00  
EEPROM contents (hex):  
0x20: 01 15 02 04 00 42 B5 E3 49 06 94 03 00 00 00 00  
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
Slot database information:  
Flags: 0x4  
Insertion time: 0x14A4 (00:23:00 ago)  
Controller Memory Size: 32 MBytes DRAM, 2048 KBytes SRAM  
PA Bay 0 Information:  
E3 Serial PA, 1 port  
EEPROM format version 1  
HW rev 1.00, Board revision AO  
Serial number: 3549502 Part number: 73-2620-02  
To determine which type of port adapter is installed on a Catalyst RSM/VIP2 in your system, use the  
show diag command. Specific port adapter information is displayed, as shown in the following  
example of a one-port PA-E3:  
router# show diag 1  
Slot 1:  
Physical slot 1, ~physical slot 0xD, logical slot 1, CBus 0  
Microcode Status 0x4  
Master Enable, LED, WCS Loaded  
Board is analyzed  
Pending I/O Status: None  
EEPROM format version 1  
VIP2 controller, HW rev 2.4, board revision D0  
Serial number: 04371939 Part number: 73-1684-03  
Test history: 0x00  
Flags: cisco 7500  
RMA number: 00-00-00  
EEPROM contents (hex):  
0x20: 01 15 02 04 00 42 B5 E3 49 06 94 03 00 00 00 00  
0x30: 68 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00  
Slot database information:  
Flags: 0x4  
Insertion time: 0x14A4 (00:23:00 ago)  
Note The slot values displayed by some commands (such as show diag and show controllers  
cbus) are not relevant to any physical connection; disregard these slot values for the  
Catalyst RSM/VIP2.  
Configuring the PA-E3 Interfaces 8-17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
For a VIP2, use the show controllers cbus command to display all of the current interface  
processors and their interfaces. Following is an example of the show controllers cbus command that  
shows serial port 1/0/0 on a one-port PA-E3 installed on a VIP2 in chassis slot 1:  
router# show controllers cbus  
MEMD at 40000000, 2097152 bytes (unused 4288, recarves 1, lost 0)  
RawQ 48000100, ReturnQ 48000108, EventQ 48000110  
BufhdrQ 48000138 (2810 items), LovltrQ 48000150 (20 items, 2016 bytes)  
IpcbufQ 48000160 (32 items, 4096 bytes)  
IpcbufQ_classic 48000158 (8 items, 4096 bytes)  
3570 buffer headers (48002000 - 4800FF10)  
pool0: 9 buffers, 256 bytes, queue 48000140  
pool1: 458 buffers, 1536 bytes, queue 48000148  
pool2: 229 buffers, 4512 bytes, queue 48000168  
pool3: 4 buffers, 4544 bytes, queue 48000170  
slot0: VIP2, hw 2.4, sw 21.40, ccb 5800FF20, cmdq 48000080, vps 8192  
software loaded from system  
IOS (tm) VIP Software (SVIP-DW-M), Version 11.1(16)CA  
ROM Monitor version 17.0  
Ethernet0/0/0, addr 00e0.f7d7.cb00 (bia 00e0.f7d7.cb00)  
gfreeq 48000148, lfreeq 48000178 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 2, maxrxcurr 4  
txq 48001A00, txacc 48001A02 (value 152), txlimit 152  
Ethernet0/0/1, addr 00e0.f7d7.cb01 (bia 00e0.f7d7.cb01)  
gfreeq 48000148, lfreeq 48000180 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A08, txacc 48001A0A (value 0), txlimit 152  
Ethernet0/0/2, addr 00e0.f7d7.cb02 (bia 00e0.f7d7.cb02)  
gfreeq 48000148, lfreeq 48000188 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A10, txacc 48001A12 (value 0), txlimit 152  
Ethernet0/0/3, addr 00e0.f7d7.cb03 (bia 00e0.f7d7.cb03)  
gfreeq 48000148, lfreeq 48000190 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A18, txacc 48001A1A (value 0), txlimit 152  
(Display text omitted.)  
8-18  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the ping Command to Verify Network Connection  
For a Catalyst RSM/VIP2, use the show controllers cbus command to display all of the current  
interfaces. Following is an example of the show controllers cbus command that shows serial port  
0/0 on a one-port PA-E3 installed on a Catalyst RSM/VIP2:  
router# show controllers cbus  
MEMD at 40000000, 2097152 bytes (unused 4288, recarves 1, lost 0)  
RawQ 48000100, ReturnQ 48000108, EventQ 48000110  
BufhdrQ 48000138 (2810 items), LovltrQ 48000150 (20 items, 2016 bytes)  
IpcbufQ 48000160 (32 items, 4096 bytes)  
IpcbufQ_classic 48000158 (8 items, 4096 bytes)  
3570 buffer headers (48002000 - 4800FF10)  
pool0: 9 buffers, 256 bytes, queue 48000140  
pool1: 458 buffers, 1536 bytes, queue 48000148  
pool2: 229 buffers, 4512 bytes, queue 48000168  
pool3: 4 buffers, 4544 bytes, queue 48000170  
slot0: VIP2, hw 2.4, sw 21.40, ccb 5800FF20, cmdq 48000080, vps 8192  
software loaded from system  
IOS (tm) VIP Software (SVIP-DW-M), Version 11.1(16)CA  
ROM Monitor version 17.0  
Ethernet0/0, addr 00e0.f7d7.cb00 (bia 00e0.f7d7.cb00)  
gfreeq 48000148, lfreeq 48000178 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 2, maxrxcurr 4  
txq 48001A00, txacc 48001A02 (value 152), txlimit 152  
Ethernet0/1, addr 00e0.f7d7.cb01 (bia 00e0.f7d7.cb01)  
gfreeq 48000148, lfreeq 48000180 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A08, txacc 48001A0A (value 0), txlimit 152  
Ethernet0/2, addr 00e0.f7d7.cb02 (bia 00e0.f7d7.cb02)  
gfreeq 48000148, lfreeq 48000188 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A10, txacc 48001A12 (value 0), txlimit 152  
Ethernet0/3, addr 00e0.f7d7.cb03 (bia 00e0.f7d7.cb03)  
gfreeq 48000148, lfreeq 48000190 (1536 bytes), throttled 0  
rxlo 4, rxhi 273, rxcurr 0, maxrxcurr 0  
txq 48001A18, txacc 48001A1A (value 0), txlimit 152  
(Display text omitted.)  
Note The slot values displayed by some commands (such as show diag and show controllers  
cbus) are not relevant to any physical connection; please disregard these slot values for the  
Catalyst RSM/VIP2.  
For complete command descriptions and examples for the Cisco 7100 series routers, Cisco 7200  
series routers, Cisco uBR7200 series routers, the VIP2, and the Catalyst RSM/VIP2, refer to the  
publications listed in the “Related Documentation” section on page vi.  
Using the ping Command to Verify Network Connection  
The ping command allows you to verify that an interface port is functioning properly and to check  
the path between a specific port and connected devices at various locations on the network. For  
example, after you verify that the system and VIP2 have booted successfully and are operational,  
you can use the ping command to verify the status of interface ports. Refer to the publications listed  
in the “Related Documentation” section on page vi for detailed command descriptions and  
examples.  
The ping command sends an echo request out to a remote device at an IP address that you specify.  
After sending a series of signals, the command waits a specified time for the remote device to echo  
the signals. Each returned signal is displayed as an exclamation point (!) on the console terminal;  
Configuring the PA-E3 Interfaces 8-19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
each signal that is not returned before the specified timeout is displayed as a period (.). A series of  
exclamation points (!!!!!) indicates a good connection; a series of periods (.....) or the message [timed  
out] or [failed] indicates that the connection failed.  
Following is an example of a successful ping command to a remote server with the address 10.0.0.0:  
router# ping 10.0.0.0 <Return>  
Type escape sequence to abort.  
Sending 5, 100-byte ICMP Echoes to 1.1.1.10, timeout is 2 seconds:  
!!!!!  
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/15/64 ms  
router#  
If the connection fails, verify that you have the correct IP address for the server and that the server  
is active (powered on), and repeat the ping command. Refer to the publications listed in the “Related  
Documentation” section on page vi for complete descriptions of interface subcommands and the  
configuration options available for VIP2-related interfaces, and to determine which subcommands  
and configuration options support VIP2 functionality.  
Using the loopback Command to Verify the Physical Interface  
Use the loopback {dte | local | network {line | payload} command to troubleshoot the E3 serial  
port adapter at the physical interface level. The command loops all packets from the E3 interface  
either back to the interface or from the network back out toward the network. Use the no form of the  
command to remove the loop.  
The following examples of the loopback {dte | local | network {line | payload} command configure  
loopback modes on the single interface (interface 0) of a one-port E3 serial port adapter in port  
adapter slot 0 of a VIP2 in chassis slot 10 of a Cisco 7500 series router:  
Set the interface into loopback data terminal equipment (DTE) mode as follows:  
Router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)# interface serial 10/0/0  
router(config-if)# loopback dte  
Loopback DTE loops the router output data back toward the router (after the line interface unit).  
Set the interface into local loopback mode as follows:  
Router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)# interface serial 10/0/0  
router(config-if)# loopback local  
Local loopback loops the router output data back toward the router at the framer.  
Set the interface into network line loopback mode as follows:  
Router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)# interface serial 10/0/0  
router(config-if)# loopback network line  
Network line loopback loops the data back toward the network (before the framer).  
8-20  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the loopback Command to Verify the Physical Interface  
Set the interface into network payload loopback mode as follows:  
Router# configure terminal  
Enter configuration commands, one per line. End with CNTL/Z.  
router(config)# interface serial 10/0/0  
router(config-if)# loopback network payload  
Network payload loopback loops just the payload data back toward the network at the E3 framer.  
Configuring the PA-E3 Interfaces 8-21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Configuration  
8-22  
PA-E3 Serial Port Adapter Installation and Configuration  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Best Ventilation Hood IEX42 User Manual
Black Decker Sander 6124 User Manual
Blanco Indoor Furnishings 157 136 User Manual
Bosch Appliances Range Gas free standing Range with Mechanical controls User Manual
Cabletron Systems Switch ELS10 26TX User Manual
Campbell Hausfeld Air Compressor HM7500 User Manual
Canon Camera Flash 2356A002 User Manual
Casio Watch MA1004 EA User Manual
CFM Corporation Electric Heater RMC TT15P User Manual
Chauvet Work Light LG 3355 User Manual