PERFORMANCE MULTI-ROOM VIDEO
Coaxial Cable Panel
Instruction Manual
®
For use with model
2100A IR wallplates
model 3308 Coax Panel
Model 3308
R
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A.
Download from Www.Somanuals.com. All Manuals Search And Download.
If the coax panel is not located at the media center, you may add a
model 2010 remote power wall plate at the media center and connect
the 3308 and 2010 with a single coax cable. The model 2010 will power
the 3308, drive the IR emitters and deliver any modulator signals to the
3308. In addition, the 2010 has connectors for 2 IR emitters. (The
model 2174 IR expansion panel will expand each of these ports to
drive up to 4 IR emitters.)
IR Repeating System
With the model 3308, you can also control your video devices from any
room in the house. Any or all 8 outputs may be connected to model
2100A wall plates. The wall plates interface with a variety of industry
standard IR targets. Direct your IR remote control at the IR target and
the 2173 IR emitter will repeat the IR signals in the media center.
Model 2132
2
Compatible IR Targets
Model 2010
Model 2173
Are repeated at
the media
VIDEO SYSTEM
POWER
15VDC
Model 2171 IR Emitter
The 2010 must be
powered as shown.
Model 2131
IR
EMITTERS
Model 2130A
SYSTEM POWER
Normally, the IR emitters are also connected to Model 2100A wall
plates. But, if the coax panel is located in the media center, you may
choose to connect the emitters to a model 2184 IR breakout panel.
Both examples are shown below. The model 2184 plugs directly into
the 3308, replacing the power adaptor cable. The 2184 can drive up to
4 IR emitters.
Modulators may
be connected here.
FROM
MODULATOR
When using IR repeating,
only a 2100A or DC block
may be directly connected
to a 3308 output.
DC block
Model 2173
Model 2100A
Model 2010 MUST be
connected to the ‘B’ port.
More modulators may be
connected to the ‘A’ port.
TARGET
2
LED
EMITTER
Max recommended
cable length 150’ (Total
of these two pieces.)
Model 2173
POWER
Are repeated at the media
center. Change the DSS
TO
TV
Model 2184
channel or pause the
VCR from any room.
IR targets must be connected
to a model 2100A wall plate.
IR targets must be connected
to a model 2100A wall plate.
RGET
Model 2132
LED
EMITTER
LED
EMITTER
Model 2130A
POWER
POWER
TO
TV
TO
TV
Model 2100A
Model 2100A
1
1
IR control signals
from the bedroom …
IR control signals
from the bedroom …
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting the 3308
Expanding the 3308:
The model 3308 should be mounted in a location that is safe and dry. The model 3308 is
small enough to be mounted inside a stud wall. Alternatively, the 3308 may be mounted
inside a ChannelPlus Integrated Home Network enclosure.
CATV/Ant
Up to 64 TV outlets
You may connect up to 8 more
3308s to the outputs of a ‘master’
3308, for a total of 64 TV outlets.
The longest recommended coax
run is 150 feet (includes coax from
master to secondary unit and from
secondary unit to TV).
Model 3308
Model 2600
(surface mount)
Model 2601
(surface mount)
Model 3308
Model 3308
Model 2603
(in-wall mount)
Shown with
model 2613 cover
All 3308s must be powered individually.
Things to watch for:
Each 3308 can have its’ own ‘zoned’ IR control and local modulators.
(Modulators connected to a secondary 3308 will be viewable only on
those 8 TVs. IR control signals will be confined to only that 3308.)
Herringbone interference on modulator channel (diagonal lines) ...
You may have chosen a channel number that is not completely vacant. Distant UHF stations
may not be watchable, but will cause interference if you try to try to create a new channel at the
same frequency. Also, cable companies often have extra signals where there should be none.
Try moving the modulator channel to another number. You may have to add a low pass filter to
remove cable company noise. If a filter does not work, try adding a DC-block to remove
common mode interference.
Circuit Breaker
Herringbone interference on many channels, including modulator
channels (disappears when you remove the CATV/Ant feed) … The RF amplifier can be
overloaded by abnormally strong signals. Often, you can cure the problem with a simple
attenuator. Use a variable attenuator and try to find a signal level where the interference just
disappears. Sometimes, the problem is one station that is far stronger than the rest. In this
case, attenuating all of the signals with a simple attenuator will cause the desired stations to be
weak (snowy). You must reduce the strength of only the offending station. A common FM trap
will help if the problem is a nearby FM tower. If the problem is a nearby TV station, often the
station management can provide suitable filters.
The model 2010 and 3308 have built-in circuit breakers. If any of these LEDs are not
lit, reset the circuit breaker by disconnecting and reconnecting the power supply. If
the system does not reset, look for an installation error.
Model 2010
Power Injector
Note: The model 2010
must connect to
this port.
Infrared Remote Control Problems … The most common cause of IR problems are:
IR emitter not located directly above sensor on the video device. Reposition the IR emitter
TV is radiating electrical noise. Reposition IR target.
VIDEO SYSTEM
15VDC
Power LED
IR
EMITTERS
IR target is ‘seeing’ optical noise, such as a solid state flourescent lamp. Reposition IR target.
SYSTEM POWER
FROM
MODULATOR
NOTE:
We recommend using only RG-6 coax when wiring a house. Why? Although good RG-59 has
only slightly more loss than RG-6, it is harder to find good RG-59. RG-6 is a little more
expensive and a little harder to run (because it is thicker). But you will avoid surprises if you
stick to RG-6.
Remember, connecting
75 ohm terminators
TARGET
directly to the outputs is
not necessary and will
Power LED
LED
EMITTER
Power LED
OWER
cause the circuit breaker
to trip.
TO
TV
Inexpensive variable attenuator
Inexpensive DC block for RF
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications: typical @ 25OC ± 5OC
Gain: Antenna/CATV port to output:
Modulator input to output
0dB
-10dB
Ant isolation (Modulator input to CATV/Ant):
Modulator input:
>80dB
+25dBmV (+85dBuV)
50-806MHz
Bandwidth:
Max CATV/Antenna input:
Power
20dBmV (+80dBuV)
15 VDC @ 250 mA
350-076
Power supply (included):
Dimensions:
6.3“ x 0.9” x 2.5“
16cm x 2.35cm x 6.35cm
Shipping weight:
4 lbs.(1.8kg)
Warranty
Multiplex Technology, Inc. warrants this product to be free
from defects in materials and workmanship for a period of
one year from the date of purchase or MTI will repair, or at
its option, replace the defective product. To obtain
warranty service, call MTI for a return material
authorization (RMA) number and return the product
prepaid to Multiplex Technology, Inc., 3001 Enterprise
Street, Brea, CA 92821, Attention: Customer Service.
Please put the RMA number on the outside of the carton.
Any implied warranty arising from the sale of the product
including implied warranties of merchantability and fitness
for purpose are limited to the warranty stated above. MTI
shall not be responsible for losses or damages or
expenses, whether direct, consequential or incidental
arising from the use of or the inability to use this product.
Some states do not allow limitations on how long the
implied warranty lasts or the exclusion or limitation or
incidental or consequential damages, so the above
limitations and exclusions may not apply to you. This
warranty gives you specific legal rights, and you may have
other rights which may vary from state to state.
600-077 Rev. E
Download from Www.Somanuals.com. All Manuals Search And Download.
|